Configuring the Cisco Intrusion Prevention System Sensor Using the Command Line Interface 6.2
Configuring IDSM-2

Table Of Contents

Configuring IDSM-2

IDSM-2 Configuration Sequence

Verifying IDSM-2 Installation

Supported IDSM-2 Configurations

Configuring the Catalyst 6500 Series Switch for Command and Control Access to IDSM-2

Catalyst Software

Cisco IOS Software

IDSM-2 Sensing Modes

Configuring the Catalyst Series 6500 Switch for IDSM-2 in Promiscuous Mode

Understanding the Switch and IDSM-2 in Promiscuous Mode

Using the TCP Reset Interface

Configuring SPAN

Catalyst Software

Cisco IOS Software

Configuring VACL Capture

Catalyst Software

Cisco IOS Software

Configuring the mls ip ids Command

Catalyst Software

Cisco IOS Software

Configuring the Catalyst Series 6500 Switch for IDSM-2 in Inline Mode

Catalyst Software

Cisco IOS Software

Configuring the Catalyst Series 6500 Switch for IDSM-2 for Inline VLAN Pair Mode

Catalyst Software

Cisco IOS Software

Configuring EtherChannel Load Balancing

Understanding EtherChannel Load Balancing

EtherChannel and the Three Sensing Modes

Enabling ECLB

Catalyst Software

Cisco IOS Software

Disabling ECLB

Catalyst Software

Cisco IOS Software

Verifying ECLB

Catalyst Software

Cisco IOS Software

Administrative Tasks for IDSM-2

Enabling Full Memory Tests

Catalyst Software

Cisco IOS Software

Resetting IDSM-2

Catalyst Software

Cisco IOS Software

Catalyst and Cisco IOS Software Commands

Catalyst Software

Supported Supervisor Engine Commands

Unsupported Supervisor Engine Commands

Cisco IOS Software

EXEC Commands

Configuration Commands


Configuring IDSM-2



Note Catalyst 6500 Series Switch is used generically to refer to both the 6500 series switches and the 7600 series routers.



Note All IPS platforms allow ten concurrent CLI sessions.


This chapter contains procedures that are specific to configuring IDSM-2. Once you set up IDSM-2 to receive traffic from the network, you can configure it for intrusion prevention. It contains the following sections:

IDSM-2 Configuration Sequence

Verifying IDSM-2 Installation

Supported IDSM-2 Configurations

Configuring the Catalyst 6500 Series Switch for Command and Control Access to IDSM-2

IDSM-2 Sensing Modes

Configuring the Catalyst Series 6500 Switch for IDSM-2 in Promiscuous Mode

Configuring the Catalyst Series 6500 Switch for IDSM-2 in Inline Mode

Configuring the Catalyst Series 6500 Switch for IDSM-2 for Inline VLAN Pair Mode

Configuring EtherChannel Load Balancing

Administrative Tasks for IDSM-2

Catalyst and Cisco IOS Software Commands

IDSM-2 Configuration Sequence

Perform the following tasks to configure IDSM-2:

1. Configure the Catalyst 6500 series switch for command and control access to IDSM-2.

2. Log in to IDSM-2.

3. Configure the switch to send traffic to be monitored to IDSM-2.

4. Initialize IDSM-2.

Run the setup command to initialize IDSM-2. During setup, you can configure the interfaces of IDSM-2.

5. Create the service account.

6. Perform the other initial tasks, such as adding users, trusted hosts, and so forth.

7. Configure intrusion prevention.

8. Perform miscellaneous tasks to keep IDSM-2 running smoothly.

9. Upgrade the IPS software with new signature updates and service packs.

10. Reimage the application partition and the maintenance partition when needed.

For More Information

For the procedure to session to IDSM-2, see Chapter 2, "Logging In to the Sensor."

For the procedure for initializing IDSM-2, see Advanced Setup for IDSM-2, page 3-19.

For the procedure for configuring command and control access to IDSM-2, see Configuring the Catalyst 6500 Series Switch for Command and Control Access to IDSM-2.

If you need to change the interface configuration, see Chapter 5, "Configuring Interfaces."

For the procedure for creating the service account, see Creating the Service Account, page 4-13.

For the procedures for setting up the sensor, see Chapter 4, "Setting Up the Sensor."

For the procedures for configuring intrusion prevention, see Chapter 7, "Configuring Event Action Rules," Chapter 8, "Defining Signatures," Chapter 9, "Configuring Anomaly Detection," and Chapter 13, "Configuring Attack Response Controller for Blocking and Rate Limiting."

For the procedures for administrative tasks for IDSM-2, see Chapter 16, "Administrative Tasks for the Sensor." and Administrative Tasks for IDSM-2.

For more information on how to obtain the most recent IPS software, see Chapter 22, "Obtaining Software."

For the procedures for reimaging the application and maintenance partitions, see Installing the IDSM-2 System Image, page 23-28.

Verifying IDSM-2 Installation

Use the show module command to verify that the switch acknowledges IDSM-2 and has brought it online.


Note It is normal for the status to read other when IDSM-2 is first installed. After IDSM-2 completes the diagnostics routines and comes online, the status reads ok. Allow up to 5 minutes for IDSM-2 to come online.


To verify the installation, follow these steps:


Step 1 Log in to the console.

Step 2 Verify that IDSM-2 is online:

Catalyst Software

console> (enable) show module
Mod Slot Ports Module-Type               Model               Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1   1    2     1000BaseX Supervisor      WS-X6K-SUP1A-2GE    yes ok
15  1    1     Multilayer Switch Feature WS-F6K-MSFC         no  ok
2   2    48    10/100BaseTX Ethernet     WS-X6248-RJ-45      no  ok
3   3    48    10/100/1000BaseT Ethernet WS-X6548-GE-TX      no  ok
4   4    16    1000BaseX Ethernet        WS-X6516A-GBIC      no  ok
6   6    8     Intrusion Detection Mod   WS-SVC-IDSM2        yes ok

Mod Module-Name          Serial-Num
--- -------------------- -----------
1                        SAD041308AN
15                       SAD04120BRB
2                        SAD03475400
3                        SAD073906RC
4                        SAL0751QYN0
6                        SAD062004LV

Mod MAC-Address(es)                        Hw     Fw         Sw
--- -------------------------------------- ------ ---------- -----------------
1   00-d0-c0-cc-0e-d2 to 00-d0-c0-cc-0e-d3 3.1    5.3.1      8.4(1)
    00-d0-c0-cc-0e-d0 to 00-d0-c0-cc-0e-d1
    00-30-71-34-10-00 to 00-30-71-34-13-ff
15  00-30-7b-91-77-b0 to 00-30-7b-91-77-ef 1.4    12.1(23)E2 12.1(23)E2
2   00-30-96-2b-c7-2c to 00-30-96-2b-c7-5b 1.1    4.2(0.24)V 8.4(1)
3   00-0d-29-f6-01-98 to 00-0d-29-f6-01-c7 5.0    7.2(1)     8.4(1)
4   00-0e-83-af-15-48 to 00-0e-83-af-15-57 1.0    7.2(1)     8.4(1)
6   00-e0-b0-ff-3b-80 to 00-e0-b0-ff-3b-87 0.102  7.2(0.67)  5.0(0.30)

Mod Sub-Type                Sub-Model           Sub-Serial  Sub-Hw Sub-Sw
--- ----------------------- ------------------- ----------- ------ ------
1   L3 Switching Engine     WS-F6K-PFC          SAD041303G6 1.1
6   IDS 2 accelerator board WS-SVC-IDSUPG       .           2.0
console> (enable)

Cisco IOS Software

router# show module
Mod Ports Card Type                              Model              Serial No.
--- ----- -------------------------------------- ------------------ -----------
  1   48  48 port 10/100 mb RJ-45 ethernet       WS-X6248-RJ-45     SAD0401012S
  2   48  48 port 10/100 mb RJ45                 WS-X6348-RJ-45     SAL04483QBL
  3   48  SFM-capable 48 port 10/100/1000mb RJ45 WS-X6548-GE-TX     SAD073906GH
  6   16  SFM-capable 16 port 1000mb GBIC        WS-X6516A-GBIC     SAL0740MMYJ
  7    2  Supervisor Engine 720 (Active)         WS-SUP720-3BXL     SAD08320L2T
  9    1  1 port 10-Gigabit Ethernet Module      WS-X6502-10GE      SAD071903BT
 10    3  Anomaly Detector Module                WS-SVC-ADM-1-K9    SAD084104JR
 11    8  Intrusion Detection System             WS-SVC-IDSM2       SAD05380608
 13    8  Intrusion Detection System             WS-SVC-IDSM-2      SAD072405D8

Mod MAC addresses                       Hw    Fw           Sw           Status
--- ---------------------------------- ------ ------------ ------------ -------
  1  00d0.d328.e2ac to 00d0.d328.e2db   1.1   4.2(0.24)VAI 8.5(0.46)ROC Ok
  2  0003.6c14.e1d0 to 0003.6c14.e1ff   1.4   5.4(2)       8.5(0.46)ROC Ok
  3  000d.29f6.7a80 to 000d.29f6.7aaf   5.0   7.2(1)       8.5(0.46)ROC Ok
  6  000d.ed23.1658 to 000d.ed23.1667   1.0   7.2(1)       8.5(0.46)ROC Ok
  7  0011.21a1.1398 to 0011.21a1.139b   4.0   8.1(3)       12.2(PIKESPE Ok
  9  000d.29c1.41bc to 000d.29c1.41bc   1.3   Unknown      Unknown      PwrDown
 10  000b.fcf8.2ca8 to 000b.fcf8.2caf   0.101 7.2(1)       4.0(0.25)    Ok
 11  00e0.b0ff.3340 to 00e0.b0ff.3347   0.102 7.2(0.67)    5.0(1)       Ok
 13  0003.feab.c850 to 0003.feab.c857   4.0   7.2(1)       5.0(1)       Ok

Mod Sub-Module                  Model              Serial        Hw     Status
--- --------------------------- ------------------ ------------ ------- -------
  7 Policy Feature Card 3       WS-F6K-PFC3BXL     SAD083305A1   1.3    Ok
  7 MSFC3 Daughterboard         WS-SUP720          SAD083206JX   2.1    Ok
 11 IDS 2 accelerator board     WS-SVC-IDSUPG      .             2.0    Ok
 13 IDS 2 accelerator board     WS-SVC-IDSUPG      0347331976    2.0    Ok

Mod Online Diag Status
--- -------------------
  1 Pass
  2 Pass
  3 Pass
  6 Pass
  7 Pass
  9 Unknown
 10 Not Applicable
 11 Pass
 13 Pass
router#


For More Information

For the procedure for enabling a full memory test after verifying IDSM-2 installation, see Enabling Full Memory Tests.

Supported IDSM-2 Configurations

Table 20-1 lists the minimum supported configurations for IDSM-2.

Table 20-1 Minimum Catalyst 6500 Software Version for IDSM-2 Feature Support 

Catalyst/IDSM-2 Feature
Catalyst Software
Cisco IOS Software
 
Sup1
Sup2
Sup32
Sup720
Sup1
Sup2
Sup32
Sup720

SPAN

7.5(1)

7.5(1)

8.4(1)

8.1(1)

12.1(19)E1

12.1(19)E1
12.2(18)SXF1

12.2(18)SXF1

12.2(14)SX1

VACL capture1

7.5(1)

7.5(1)

8.4(1)

8.1(1)

12.1(19)E1

12.1(19)E1
12.2(18)SXF1

12.2(18)SXF1

12.2(14)SX1

ECLB with VACL capture2

8.5(1)

8.5(1)

8.5(1)

8.5(1)

N/A

12.2(18)SXF4

12.2(18)SXF1

12.2(18)SXE1

Inline interface pairs

8.4(1)

8.4(1)

8.4(1)

8.4(1)

N/A

12.2(18)SXF4

12.2(18)SXF4

12.2(18)SXE1

ECLB with inline interface pairs

8.5(1)

8.5(1)

8.5(1)

8.5(1)

N/A

12.2(18)SXF4

12.2(18)SXF4

12.2(18)SXF4

Inline VLAN pairs

8.4(1)

8.4(1)

8.4(1)

8.4(1)

N/A

12.2(18)SXF4

12.2(18)SXF4

12.2(18)SXF4

ECLB with inline VLAN pairs

8.5(1)

8.5(1)

8.5(1)

8.5(1)

N/A

12.2(18)SXF4

12.2(18)SXF4

12.2(18)SXF4

1 Requires PFC2/3 or MSFC2/3.

2 Requires PFC2/3 or MSFC2/3.


Configuring the Catalyst 6500 Series Switch for Command and Control Access to IDSM-2

You must configure the Catalyst 6500 series switch to have command and control access to IDSM-2. This section describes how to configure command and control access to IDSM-2, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

To configure the Catalyst 6500 series switch to have command and control access to IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Put the command and control port into the correct VLAN.

console> (enable) set vlan command_and_control_vlan_number 
idsm2_slot_number/command_and_control_port_number

Example

console> (enable) set vlan 147 6/2
VLAN 147 modified.
VLAN 146 modified.
VLAN  Mod/Ports
---- -----------------------
147   2/5,2/16-18
      6/2

The command and control port number is always 2.

Step 4 Session to IDSM-2 and ping a network IP address.

console> session slot_number
idsm-2# ping network_ip_address

Example

console> (enable) session 6
Trying IDS-6...
Connected to IDS-6.
Escape character is '^]'.

login: cisco
Password: 
Last login: Thu Mar 3 09:40:53 from 127.0.0.11
***NOTICE***
This product contains cryptographic features and is subject to United States and local 
country laws governing import, export, transfer and use. Delivery of Cisco cryptographic 
products does not imply third-party authority to import, export, distribute or use 
encryption. Importers, exporters, distributors and users are responsible for compliance 
with U.S. and local country laws. By using this product you agree to comply with 
applicable laws and regulations. If you are unable to comply with U.S. and local laws, 
return this product immediately.

A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html

If you require further assistance please contact us by sending email to
export@cisco.com.

***LICENSE NOTICE***
There is no license key installed on the system.
Please go to http://www.cisco.com/go/license to obtain a new license or install a license.
idsm-2# ping 10.89.149.126
PING 10.89.149.126 (10.89.149.126): 56 data bytes
64 bytes from 10.89.149.126: icmp_seq=0 ttl=255 time=0.3 ms
64 bytes from 10.89.149.126: icmp_seq=1 ttl=255 time=0.3 ms
64 bytes from 10.89.149.126: icmp_seq=2 ttl=255 time=0.3 ms
64 bytes from 10.89.149.126: icmp_seq=3 ttl=255 time=0.3 ms
--- 10.89.149.126 ping statistics ---
4 packets transmitted, 4 packets received, 0% packet loss
round-trip min/avg/max = 0.3/0.3/0.3 ms
idsm-2# exit
console> (enable) 

Step 5 Initialize IDSM-2.

Step 6 Ping the default router of IDSM-2.

Step 7 Verify the management station can ping, SSH or Telnet, and web browse to IDSM-2.


For More Information

For the procedure for using the setup command to initialize IDSM-2, see Advanced Setup for IDSM-2, page 3-19.

Cisco IOS Software

To configure the Catalyst 6500 series switch to have command and control access to IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 Put the command and control port into the correct VLAN.

router (config)# intrusion-detection module module_number management-port access-vlan 
vlan_number

Example

router (config)# intrusion-detection module 11 management-port access-vlan 146

Step 4 Verify that you have connectivity by sessioning in to IDSM-2 and pinging a network IP address.

router# session slot module_number processor 1
idsm-2# ping network_ip_address

Example

router# session slot 11 processor 1
The default escape character is Ctrl-^, then x.
You can also type 'exit' at the remote prompt to end the session
Trying 127.0.0.91 ... Open

login: cisco
Password: 
***NOTICE***
This product contains cryptographic features and is subject to United States and local 
country laws governing import, export, transfer and use. Delivery of Cisco cryptographic 
products does not imply third-party authority to import, export, distribute or use 
encryption. Importers, exporters, distributors and users are responsible for compliance 
with U.S. and local country laws. By using this product you agree to comply with 
applicable laws and regulations. If you are unable to comply with U.S. and local laws, 
return this product immediately.

A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html

If you require further assistance please contact us by sending email to
export@cisco.com.
***LICENSE NOTICE***
There is no license key installed on the system.
Please go to http://www.cisco.com/go/license
to obtain a new license or install a license.
idsm-2# ping 10.89.149.254
PING 10.89.149.254 (10.89.149.254): 56 data bytes
64 bytes from 10.89.149.254: icmp_seq=0 ttl=255 time=0.2 ms
64 bytes from 10.89.149.254: icmp_seq=1 ttl=255 time=0.2 ms
64 bytes from 10.89.149.254: icmp_seq=2 ttl=255 time=0.2 ms
64 bytes from 10.89.149.254: icmp_seq=3 ttl=255 time=0.2 ms
--- 10.89.149.254 ping statistics ---
4 packets transmitted, 4 packets received, 0% packet loss
round-trip min/avg/max = 0.2/0.2/0.2 ms
idsm-2# exit
[Connection to 127.0.0.91 closed by foreign host]
router#

Step 5 Initialize IDSM-2.


For More Information

For the procedure for using the setup command to initialize IDSM-2, see Advanced Setup for IDSM-2, page 3-19.

IDSM-2 Sensing Modes

IDSM-2 supports three sensing modes:

Promiscuous mode—When IDSM-2 was introduced, promiscuous mode was the only sensing mode supported on IDSM-2 and it is the default sensing mode for both data ports.

In promiscuous mode, IDSM-2 passively monitors network traffic copied to its data ports by the Catalyst switch. The data ports operate as 802.1q trunks and you can configure the two data ports to trunk the same or different VLANs. The Catalyst switch uses either SPAN or VACL capture to copy specific traffic to the data ports. You can send the same or different traffic to the two data ports. Because IDSM-2 is passive in this mode, it cannot drop packets to block a network intrusion attempt, but you can configure it to send TCP resets to both sides of the network connection to try to break the connection.


Note Because the Catalyst switch does not forward traffic received from a capture destination port, IDSM-2 cannot send TCP resets over the data ports to try to block an intrusion. Therefore, a separate reset port available only in promiscuous mode is reserved for this purpose.


Inline mode—Beginning with IPS 5.0(1), you can configure IDSM-2 to be an active network device in inline interface pair mode. The two data ports operate together to bridge two VLANs through IDSM-2. You configure each data port as an access port and assign a different VLAN to each data port. IDSM-2 bridges the two VLANs by forwarding traffic between the two data ports. It inspects the traffic it receives on each data port and can either forward the packets to the other data port or drop the packet if it detects intrusion. You must configure the switch for inline mode, and then create the inline interface pairs on IDSM-2.

Inline VLAN pair mode—Beginning with IPS 5.1(1), you can configure IDSM-2 in inline VLAN pair mode. IDSM-2 performs VLAN bridging between pairs of VLANs within the same data port operating as an 802.1q trunk. IDSM-2 inspects the traffic it receives on each VLAN in a VLAN pair and can either forward the packets on the other VLAN in the pair (on the same data port on which the packet was received) or drop the packet if an intrusion is detected. You can configure IDSM-2 to simultaneously bridge up to 255 VLAN pairs on each data port. IDSM-2 replaces the VLAN ID field in the 802.1q header of each packet with the ID of the VLAN on which the packet is forwarded. It drops any packets received on VLANs that are not assigned to an inline VLAN pair.


Note You are responsible for coordinating the IPS and switch configuration to make sure each of the VLANS associated with an inline VLAN pair is also an allowed VLAN for the data port trunk.


You can mix sensing modes on IDSM-2. For example, you can configure one data port for promiscuous mode and the other data port for inline VLAN pair mode. But because IDSM-2 only has two data ports and inline mode requires the use of both data ports as a pair, you cannot mix inline mode with either of the other two modes.

For More Information

For more information on promiscuous mode, see Promiscuous Mode, page 5-15.

For more information on TCP reset, see TCP Reset Interfaces, page 5-4.

For the procedure for configuring SPAN, see Configuring SPAN.

For the procedure for configuring VACL capture, see Configuring VACL Capture.

For more information on inline interface mode, see Inline Interface Mode, page 5-16.

For more information on configuring the switch for inline interface mode, see Configuring the Catalyst Series 6500 Switch for IDSM-2 in Inline Mode.

For more information on configuring IDSM-2 in inline interface mode, see Configuring Inline Interface Pairs, page 5-17.

For more information on Inline VLAN pair mode, see Inline VLAN Pair Mode, page 5-21.

For the procedure for configuring the switch for Inline VLAN pair mode, see Configuring the Catalyst Series 6500 Switch for IDSM-2 for Inline VLAN Pair Mode.

For the procedure for configuring IDSM-2 in Inline VLAN pair mode, see Configuring Inline VLAN Pairs, page 5-22.

Configuring the Catalyst Series 6500 Switch for IDSM-2 in Promiscuous Mode

This section describes how to configure the switch and IDSM-2 for promiscuous mode, and contains the following topics:

Understanding the Switch and IDSM-2 in Promiscuous Mode

Using the TCP Reset Interface

Configuring SPAN

Configuring VACL Capture

Configuring the mls ip ids Command

Understanding the Switch and IDSM-2 in Promiscuous Mode

Traffic is captured for promiscuous analysis on IDSM-2 through SPAN or VACL capture (if you are running the Cisco IOS Firewall on the MSFC, you cannot use VACLs, but you can use the mls ip ids command). Port 1 (GigabitEthernet0/1) is used as the TCP reset port, port 2 (GigabitEthernet0/2) is the command and control port, and ports 7 and 8 (GigabitEthernet0/7 and GigabitEthernet0/8) are the monitoring ports. You can configure both monitoring ports to be either SPAN destination ports or VACL capture ports.


Caution If you configure both ports as monitoring ports, make sure that they are configured to monitor different traffic.


Caution You should not configure an IDSM-2 data port as both a SPAN destination port and a VACL capture port, because IDSM-2 will not receive traffic. This dual configuration (SPAN and VACL) causes problems on the switch and traffic is not sent properly.


Note Before Catalyst Software 8.4(3), IDSM-2 data ports defaulted to trunking all VLANs. In Catalyst Software 8.4(3) and later, IDSM-2 data ports default to trunking no VLANs. Make sure that the IDSM-2 ports are trunking the proper VLANs, especially if you are upgrading from pre-8.4(3) to 8.4(3) or later.


Using the TCP Reset Interface

The IDSM-2 has a TCP reset interface—port 1. The IDSM-2 has a specific TCP reset interface because it cannot send TCP resets on its sensing ports.

If you have reset problems with the IDSM-2, try the following:

If the sensing ports are access ports (a single VLAN), you need to configure the reset port to be in the same VLAN.

If the sensing ports are dot1q trunk ports (multi-VLAN), the sensing ports and reset port all must have the same native VLAN, and the reset port must trunk all the VLANs being trunked by both the sensing ports.

Configuring SPAN

IDSM-2 can analyze Ethernet VLAN traffic from Ethernet or Fast Ethernet SPAN source ports, or you can specify an Ethernet VLAN as the SPAN source. This section describes how to use SPAN with IDSM-2, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software


Note IDSM-2 port numbers are 7 or 8 only.


Use the set span command in privileged mode to enable SPAN to IDSM-2.

The following options apply:

disable—Disables port monitoring.

module/port—Source module and port numbers.

vlan—Source VLAN numbers.

module/port—Destination module and port numbers.

both—Both receiving and transmitting traffic.

filter—Applies filter to VLAN.

inpkts—Enables/disables destination port incoming packets.

learning—Enables/disables MAC address learning.

multicast—Enables/disables multicast traffic.

rx—Receiving traffic.

session— Session number for SPAN session.

tx —Transmitting traffic.

To enable SPAN on IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Enable SPAN to IDSM-2:

From a source port

console> (enable) set span 3/3 13/7
Destination     : Port 13/7
Admin Source    : Port 3/3
Oper Source     : Port 3/3
Direction       : transmit/receive
Incoming Packets: disabled
Learning        : enabled
Multicast       : enabled
Filter          : -

Session Number  : 1

console> (enable) 


Note Use the filter keyword to monitor traffic on specific VLANs on source trunk ports.


From a VLAN

console> (enable) set span 650 13/7 rx

Destination : Port 13/7
Admin Source : VLAN 650
Oper Source : Port 11/1,13/1
Direction : receive
Incoming Packets: disabled
Learning : enabled
Multicast : enabled
Filter : -

Session Number : 1

console> (enable) 

Step 4 Show the SPAN sessions.

console> (enable) show span 

Destination     : Port 13/7
Admin Source    : VLAN 650
Oper Source     : Port 11/1,13/1
Direction       : receive
Incoming Packets: disabled
Learning        : enabled
Multicast       : enabled
Filter          : -

Session Number  : 1

Total local span sessions:  1
console> (enable) 

Step 5 To disable the SPAN session that is sending traffic to IDSM-2.

console> (enable) set span disable session 1
This command will disable your span session.
Do you want to continue (y/n) [n]? y
Disabled Port 13/7 to monitor receive traffic of VLAN 650
console> (enable)


Cisco IOS Software


Note Use 1 or 2 for IDSM-2 data port numbers.


Use the monitor session command in global configuration mode to enable SPAN on IDSM-2.

The following options apply:

interface—SPAN source interface

remote—SPAN source Remote

vlan— SPAN source VLAN

GigabitEthernet— GigabitEthernet IEEE 802.3z

Port-channel— Ethernet Channel of interfaces

,— Specify another range of interfaces

--— Specify a range of interfaces

both— Monitor received and transmitted traffic

rx— Monitor received traffic only

tx— Monitor transmitted traffic only

intrusion-detection-module— SPAN destination intrusion detection module

destination— SPAN destination interface or VLAN

filter— SPAN filter VLAN

source— SPAN source interface, VLAN

type— Type of monitor session

To enable SPAN on IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 Set the source interfaces for the monitor session.

router(config)# monitor session (session_number) source interface interface/port_number 
[, | - | rx | tx | both]

Example

router(config)# monitor session 1 source interface GigabitEthernet2/23 both

Step 4 Enable an IDSM-2 data port as a SPAN destination.

router(config)# monitor session (session_number) destination intrusion-detection-module 
module_number data-port data_port_number

Example

router(config)# monitor session 1 destination intrusion-detection-module 9 data-port 1

Step 5 Make sure autostate is included for the data port.

router(config)# intrusion-detection module module_number data-port data_port_number 
autostate include

Example

router(config)# intrusion-detection module 9 data-port 1 autostate include

This allows the switch virtual interface to stay up if the data port is the only port in the VLAN. The default is no include.

Step 6 (Optional) Enable portfast for the data port.

router(config)# intrusion-detection module module_number data-port data_port_number 
portfast

Example

router(config)# intrusion-detection module 9 data-port 1 portfast

The default is disabled.

Step 7 (Optional) To disable the monitor session.

router(config)# no monitor session session_number

Step 8 (Optional) To filter the SPAN session so that only certain VLANs are seen from switch port trunks.

router(config)# monitor session (session_number) {filter vlan {vlan_ID} [, | - ]}

Example

router(config)# monitor session 1 filter vlan 146

Step 9 Exit configuration mode.

router(config)# exit

Step 10 Show current monitor sessions.

router# show monitor session session_number

Example

router# show monitor session 1
    Session 1
    ---------
    Type                   : Local Session
    Source Ports           : 
        Both               : Gi2/23
    Destination Ports      : intrusion-detection-module 9 data-port 1


For More Information

For more information on autostate and portfast, refer to Catalyst 6500 Series Software Configuration Guide, 8.x.

Configuring VACL Capture

You can set VACLs to capture traffic for IPS from a single VLAN or from multiple VLANs or from FLexWAN2 ports on the 7600 router when using Cisco IOS software. This section describes how to use VACLS to capture traffic, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software


Note Port 1 is set as the TCP reset port. Ports 7 and 8 are the sensing ports and can be configured as security ACL capture ports. By default, in Catalyst Software 8.4(1) and earlier releases, ports 7 and 8 are configured as trunk ports and trunk all VLANs on which a security ACL has been applied with the capture feature. If you want to monitor traffic from specific VLANs only, you need to clear the VLANs that you do not want to monitor so that they are not trunked to ports 7 and 8.


Use the set security acl command to configure security ACL capture ports.

The following options apply:

ACL—Sets security ACL features

capture-port—Sets ports for ACL capture

cram—Sets security ACL cram

ip —Sets IP security ACL features

ipx—Sets IPX security ACL features

mac—Sets MAC security ACL features

map— Sets security ACL to VLAN mapping

permit—Specifies packets to forward

deny—Specifies packets to reject

redirect—Specifies packets to redirect to ports

before—Inserts ACE before a specified ace in editbuffer

capture—Makes a copy of this flow in capture ports

modify— Modifies a specified ACE in editbuffer

To configure VACLs to capture IPS traffic on VLANs, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Create the VACL to capture traffic. Specify what traffic is permitted, denied, and captured.

console> (enable) set security acl ip acl_name permit ip [permit (...) | deny (...)] 
capture


Note Only permitted traffic can be captured. If you want to permit traffic but not capture it, do no use the capture keyword


Example

console> (enable) set security acl ip CAPTUREALL permit ip any any capture
CAPTUREALL editbuffer modified. Use 'commit' command to apply changes.

Step 4 Commit the VACL.

console> (enable) commit security acl CAPTUREALL
ACL commit in progress.

Committing the VACL writes the VACL and associated ACEs to NVRAM.

Step 5 Map the VACL to the VLANs.

console> (enable) set security acl map acl_name vlan_number

Example

console> (enable) set security acl map CAPTUREALL 650
Mapping in progress.

ACL CAPTUREALL successfully mapped to VLAN 650.

Step 6 Configure IDSM-2 ports (port 7 or 8) to be capture ports.

console> (enable) set security acl capture module_number/port_number

Example

console> (enable) set security acl capture 2/13
Successfully set 2/13 to capture ACL traffic.


Cisco IOS Software

Use the following commands to configure VACLs to capture IPS traffic on VLANs.

The following options apply:

ip-access-list—Named access list

extended—Extended Access List

hardware—Enable Hardware Fragment Handling

log-update—Control access list log updates

logging—Control access list logging

resequence—Resequence Access List

standard—Standard Access List

To configure VACLs to capture IPS traffic on VLANs, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 Define the ACL.

router(config)# ip access-list [standard | extended] acl_name

Example

router(config)# ip access-list standard CAPTUREALL
router(config-std-nacl)# exit

Step 4 Define the VLAN access map.

router(config)# vlan access-map map_name [0-65535]

Step 5 Configure a match clause in a VLAN access map sequence.

router(config-access-map)# match [ip address {1-199 | 1300-2699 | acl_name}]

Step 6 Configure an action clause in the VLAN access map sequence to accompany the preceding match clause.

router(config-access-map)# action forward capture

Step 7 Apply the VLAN access-map to the specified VLANs.

router(config)# vlan filter map_name vlan-list vlan_list

Step 8 Configure the IDSM-2 data ports to capture the captured-flagged traffic.

router(config)# intrusion-detection module module_number data-port data_port_number 
capture allowed-vlan capture_vlans


Note When the switch is routing traffic, you should configure IDSM-2 to monitor all VLANs being routed. If you apply the VACL to a FlexWan2 port, you need to configure IDSM-2 to monitor all VLANs.


Step 9 Enable the capture function on IDSM-2.

router(config)# intrusion-detection module module_number data-port data_port_number 
capture

This example shows the output from the show run command.

router# show run
intrusion-detection module 4 data-port 1 capture allowed-vlan 450,1002-1005
intrusion-detection module 4 data-port 1 capture
.
.
.
vlan access-map CAPTUREALL 10 
match ip address MATCHALL 
action forward capture 
.
.
.
ip access-list extended MATCHALL 
permit ip any any
router# 

Step 10 Make sure autostate is included for the data port.

router(config)# intrusion-detection module module_number data-port data_port_number 
autostate include

Example

router(config)# intrusion-detection module 4 data-port 1 autostate include

This allows the switch virtual interface to stay up if the data port is the only port in the VLAN. The default is no include.

Step 11 (Optional) Enable portfast for the data port.

router(config)# intrusion-detection module module_number data-port data_port_number 
portfast

Example

router(config)# intrusion-detection module 4 data-port 1 portfast

The default is disabled.


For More Information

For more information on autostate and portfast, refer to Catalyst 6500 Series Software Configuration Guide, 8.x.

Configuring the mls ip ids Command

This section describes how to use the mls ip ids command to capture IPS traffic. It contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

When you are running the Cisco IOS Firewall on the MSFC, you cannot use VACLs to capture traffic for IDSM-2, because you cannot apply VACLs to a VLAN in which you have applied an IP inspect rule for the Cisco IOS Firewall. However, you can use the mls ip ids command to designate which packets are captured. Packets that are permitted by the ACL are captured. Those denied by the ACL are not captured. The permit/deny parameter does not affect whether a packet is forwarded to destination ports. Packets coming into that router interface are checked against the IPS ACL to determine if they should be captured. The mls ip ids command is applied as part of the MSFC configuration instead of the supervisor configuration. The mls ip ids command only captures incoming traffic. Use the mls ip ids command on both the client-side router interface and server-side router interface, so that both directions of the connection are captured.

To use the mls ip ids command to capture IPS traffic, follow these steps:


Step 1 Log in to the MSFC.

Step 2 Enter privileged mode.

console> enable

Step 3 Enter configuration mode.

router# configure terminal

Step 4 Configure an ACL to designate which packets will be captured.

router(config)# ip access-list extended word

Step 5 Select the interface that carries the packets to be captured.

router(config)# interface interface_name

Step 6 Apply the ACL created in Step 4 to the interface selected in Step 5.

router(config-if)# mls ip ids word

Step 7 Log in to the supervisor engine.

Step 8 Enter privileged mode.

console> enable

Step 9 On the supervisor engine, add the IDSM-2 monitoring port (port 7 or 8) to the VACL capture list.

console> (enable) set security acl capture module_number/port_number


Caution For IDSM-2 to capture all packets marked by the mls ip ids command, port 7 or 8 of IDSM-2 must be a member of all VLANs to which those packets are routed.


Cisco IOS Software

When you are using ports as router interfaces rather than switch ports, there is no VLAN on which to apply a VACL.

You can use the mls ip ids command to designate which packets are captured. Packets that are permitted by the ACL are captured. Those denied by the ACL are not captured. The permit/deny parameter does not affect whether a packet is forwarded to destination ports. Packets coming into that router interface are checked against the IPS ACL to determine if they should be captured.

To use the mls ip ids command to capture IDS traffic, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 Configure an ACL to designate which packets will be captured.

router(config)# ip access-list extended word

Step 4 Select the interface that carries the packets to be captured.

router(config)# interface interface_name

Step 5 Specify the capture VLANs.

router(config)# intrusion-detection module module_number data-port data_port_number 
capture allowed-vlan capture_vlans 

Example

router(config)# intrusion-detection module 4 data-port 1 capture allowed-vlan 165

Step 6 Apply the ACL created in Step 4 to the interface selected in Step 5.

router(config-if)# mls ip ids word


Caution For IDSM-2 to capture all packets marked by the mls ip ids command, data port 1 or data port 2 of IDSM-2 must be a member of all VLANs to which those packets are routed.


Configuring the Catalyst Series 6500 Switch for IDSM-2 in Inline Mode

You can use IDM or the CLI to configure IDSM-2 to operate in inline mode between two separate VLANs (one VLAN for each side of IDSM-2). To prepare IDSM-2 for inline mode, you must configure the switch as well as IDSM-2. Configure the switch first, then configure the IDSM-2 interfaces for inline mode. This section describes how to configure IDSM-2 in inline mode, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

You configure IDSM-2 monitoring ports as trunk ports for inline operation for Catalyst software 8.4(1) or later with Supervisor Engine 1a, Supervisor Engine 2, Supervisor Engine 32, or Supervisor Engine 720. Because the native VLAN is the same as the sole VLAN being trunked, the traffic is not 802.1q encapsulated.


Caution Before Catalyst software 8.4.(3), the default configuration for IDSM-2 ports 7 and 8 is to trunk all VLANs 1 to 4094. If you clear the IDSM-2 configuration (clear configuration module_number), IDSM-2 trunks all VLANs. If the IDSM-2 interfaces are configured for inline, spanning tree loops will likely be created and a storm will occur. A storm is numerous packets looping and never reaching their destination.

To configure the monitoring ports on IDSM-2 for inline operation, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Set the native VLAN for each IDSM-2 monitoring port.

console (enable)> set vlan vlan_number slot_number/port_number

Example

console (enable)> set vlan 651 9/7

console (enable)> set vlan 652 9/8

Step 4 Clear all VLANs from each IDSM-2 monitoring port (port 7 and 8).

console (enable)> clear trunk slot_number/port_number vlan_range

Example

console (enable)> clear trunk 9/7 1-4094
console (enable)> clear trunk 9/8 1-4094

Step 5 Configure IDSM-2 monitoring ports 7 and 8 to trunk the single native VLAN configured in Step 3.

console (enable)> set trunk slot_number/port_number vlan_number

Example

console (enable)> set trunk 9/7 651
console (enable)> set trunk 9/8 652

Step 6 Pair the interfaces from Step 3 on IDSM-2.


For More Information

For the procedure for pairing inline interface pairs, see Configuring Inline Interface Pairs, page 5-17.

Cisco IOS Software

Configure the IDSM-2 monitoring ports as access ports for inline operation.

To configure inline VLANs, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 Select the VLANs the IDSM-2 will link.

Step 4 Configure each IDSM-2 data port to be on a single VLAN.

router(config)# intrusion-detection module slot_number data-port {1 | 2} access-vlan 
vlan_number 
router(config)# exit

Example

router(config)# intrusion-detection module 13 data-port 1 access-vlan 661 
router(config)# intrusion-detection module 13 data-port 2 access-vlan 662 
router(config)# exit

Step 5 Verify the configuration.


Note In these examples, the IDSM-2 in slot 13 is inline between VLANs 661 and 662. The IDSM-2 data port 1 is on VLAN 661 and data port 2 is on VLAN 662.


a. Verify the IDSM-2 intrusion detection settings.

router# show run | include intrusion-detection 
intrusion-detection module 13 management-port access-vlan 147 
intrusion-detection module 13 data-port 1 access-vlan 661 
intrusion-detection module 13 data-port 2 access-vlan 662 
router#

b. Verify that the IDSM-2 data port 1 is an access port on VLAN 661.

router# show intrusion-detection module slot_number data-port data_port_number state 

Example

router# show intrusion-detection module 13 data-port 1 state
Intrusion-detection module 13 data-port 1:
Switchport: Enabled
Administrative Mode: static access
Operational Mode: static access
Administrative Trunking Encapsulation: dot1q Operational Trunking Encapsulation: 
native Negotiation of Trunking: Off Access Mode VLAN: 661 (inline-vlan-1) Trunking 
Native Mode VLAN: 1 (default) Trunking VLANs Enabled: NONE Pruning VLANs Enabled: 
2-1001 Vlans allowed on trunk:661 Vlans allowed and active in management domain: 661 
Vlans in spanning tree forwarding state and not pruned: 661
Administrative Capture Mode: Disabled
Administrative Capture Allowed-vlans: <empty>

c. Verify the VLAN number.

router# show vlan id vlan-number

Example

router# show vlan id 661
VLAN Name                             Status    Ports
---- -------------------------------- --------- -------------------------------
661  ward-attack3                     active    Gi3/2, Gi13/d1

VLAN Type  SAID       MTU   Parent RingNo BridgeNo Stp  BrdgMode Trans1 Trans2
---- ----- ---------- ----- ------ ------ -------- ---- -------- ------ ------
661  enet  100661     1500  -      -      -        -    -        0      0

Remote SPAN VLAN
----------------
Disabled

Primary Secondary Type              Ports
------- --------- ----------------- ------------------------------------------
router#

Step 6 Pair the interfaces from Step 4 on IDSM-2.


For More Information

For the procedure for pairing inline interface pairs, see Configuring Inline Interface Pairs, page 5-17.

Configuring the Catalyst Series 6500 Switch for IDSM-2 for Inline VLAN Pair Mode

You can use IDM or the CLI to configure IDSM-2 to operate in inline VLAN pair mode. To prepare IDSM-2 for inline VLAN pair mode, you must configure the switch as well as IDSM-2. Configure the switch first, then configure the IDSM-2 interfaces for inline VLAN pair mode. This section describes how to configure IDMS-2 in inline VLAN pair mode, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

You configure IDSM-2 monitoring ports as trunk ports for inline VLAN pair mode for Catalyst software 8.4(1) or later with Supervisor Engine 1a, Supervisor Engine 2, Supervisor Engine 32, or Supervisor Engine 720.

To configure the monitoring ports on IDSM-2 for inline VLAN pair mode, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Clear all VLANs from the IDSM-2 monitoring port.

console (enable)> clear trunk slot_number/port_number 1-4094

Example

console (enable)> clear trunk 9/7 1-4094


Note Before Catalyst software 8.4.(3), the value for the VLAN range when clearing VLANs from the IDSM-2 monitoring port was 1-1005, 1024-4094. In later versions you can clear the entire VLAN range, 1-4094.


Step 4 Configure the IDSM-2 monitoring port to trunk the VLANs to be paired.

console (enable)> set trunk slot_number/port_number vlans_to_be_paired

Example

console (enable)> set trunk 9/7 651,652

Step 5 Set the native VLAN for the IDSM-2 monitoring port to a value other than the paired VLANs used in Step 4.

console (enable)> set vlan vlan-number slot_number/port_number

Example

console (enable)> set vlan 1 9/7

The default native VLAN is VLAN 1.

Step 6 Repeat Step 4 for other VLANs to be paired on the IDSM-2 monitoring port.

Step 7 To configure the other monitoring port, repeat Steps 3 through 6.

Step 8 Pair the VLANs from Step 4 on IDSM-2.


For More Information

For the procedure for configuring IDSM-2 to run in inline VLAN pair mode, see Configuring Inline VLAN Pairs, page 5-22.

Cisco IOS Software

Configure the IDSM-2 monitoring ports as trunk ports for inline VLAN pair operation.

To configure inline VLAN pairs, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 Configure one IDSM-2 data port to trunk the VLANs to be paired.

router(config)# intrusion-detection module slot_number data-port data_port_number trunk 
allowed-vlan vlans_to_be_paired
router(config)# exit

Example

router(config)# intrusion-detection module 13 data-port 1 trunk allowed-vlan 661,662 
router(config)# exit

Step 4 Verify the configuration.


Note In these examples, data port 1 of IDSM-2 in slot 13 is trunking VLANs 661 and 662.


a. Verify the IDSM-2 intrusion detection settings.

router# show run | include intrusion-detection 
intrusion-detection module 13 management-port access-vlan 147 
intrusion-detection module 13 data-port 1 trunk allowed-vlan 661,662 
router#

b. Verify that the IDSM-2 data port is trunking the proper VLANs.

router# show intrusion-detection module slot_number data-port data_port_number state 

Example

router# show intrusion-detection module 13 data-port 1 state
Intrusion-detection module 13 data-port 1:
Switchport: Enabled
Administrative Mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: Off
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: 661,662
Pruning VLANs Enabled: 2-1001
Vlans allowed on trunk: 661-662
Vlans allowed and active in management domain: none
Vlans in spanning tree forwarding state and not pruned: 
   none
Administrative Capture Mode: Disabled
Administrative Capture Allowed-vlans: empty
Autostate mode: excluded
Portfast mode: default
router#

Step 5 Pair the VLANs from Step 3 on IDSM-2.


For More Information

For the procedure for configuring IDSM-2 to run in inline VLAN pair mode, see Configuring Inline VLAN Pairs, page 5-22.

Configuring EtherChannel Load Balancing

This section describes how to configure ECLB on IDSM-2, and contains the following topics:

Understanding EtherChannel Load Balancing

EtherChannel and the Three Sensing Modes

Enabling ECLB

Disabling ECLB

Verifying ECLB

Understanding EtherChannel Load Balancing

Supervisor Engines in the Catalyst 6500 series chassis recognize IDSM-2 devices that are running IPS 5.x and greater as EtherChannel devices. This lets you install up to eight IDSM-2 devices in the same chassis.

The IDSM-2 in the Catalyst 6500 series switch has eight internal ports. Only four of these ports are used. Port 1 is a TCP/IP reset port. Port 2 is the command and control port. Ports 7 and 8 are the sensing ports for Catalyst software and data ports 1 and 2 for Cisco IOS software. The other ports are not used.

The backplane is 1000 Mbps, which is why IDSM-2 shows 1000 Mbps even though it can only handle about 600 Mbps of performance. ECLB allows up to eight IDSM-2 devices to participate in the load balancing on either port 7 or port 8.

EtherChannel and the Three Sensing Modes

EtherChannel provides load balancing and failover between multiple IDSM-2s in all three sensing modes. IDSM-2 does not participate in EtherChannel protocols, such as LACP or PAgP. Cisco IOS only allows load balancing using src-dst-ip algorithm so that all packets between a given pair of IP addresses are always mapped to the same channel. Catalyst software uses the ip both algorithm. This is necessary so IDSM-2 can correctly track the connections between two hosts.


Caution You cannot mix IDSM-2 data ports with other port types in an EtherChannel group. You must configure all data ports in an EtherChannel group identically.

EtherChannel and IDSM-2 operate in the following way in the three sensing modes:

EtherChannel and promiscuous mode—When IDSM-2 operates in promiscuous mode, the two data ports operate independently of each other. If you configure the switch so that a data port has two or more IDSM-2s in a group, the switch distributes traffic between the IDSM-2s. This balances the traffic between multiple IDSM-2s. You should rebalance the channel when a data port goes to the errDisabled state, or IDSM-2 is shut down, powered down, or reset.

EtherChannel and inline mode—When you configure multiple IDSM-2s for inline mode, you can load balance the traffic between the IDSM-2s by putting data port 1 of each IDSM-2 into one channel group and data port 2 of each IDSM-2 into another channel group.


Caution To make sure that the same traffic is assigned to the two data ports on each IDSM-2, you must assign the same EtherChannel index to both data ports on each of the IDSM-2s even though they are in different EtherChannel groups.

EtherChannel and inline VLAN pair mode—When IDSM-2 is in inline on-a-stick mode, the two data ports operate independently of each other. The same restrictions apply as for promiscuous mode.

Enabling ECLB

This section describes how to enable ECLB for Cisco IOS and Catalyst software. It contains the following sections:

Catalyst Software

Cisco IOS Software

Catalyst Software

This section describes how to enable ECLB for the three sensing modes in Catalyst software. It contains the following topics:

Configuring ECLB in Promiscuous and VLAN Pair mode

Configuring ECLB in Inline Mode

Configuring ECLB in Promiscuous and VLAN Pair mode

For promiscuous mode and inline VLAN pair mode, add the single port (port 7 or port 8) from each IDSM-2 to an EtherChannel.

To configure the monitoring ports on IDSM-2 for ECLB in promiscuous or inline VLAN pair mode, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Configure each IDSM-2 for promiscuous or inline VLAN pair mode.

Step 4 Add the IDSM-2 monitoring ports to an EtherChannel.

console (enable)> set port channel slot_number/port_number channel_number

Example

console (enable)> set port channel 1/7,7/7 1

Step 5 Set the distribution method.

console (enable)> set port channel all distribution ip both
Channel distribution is set to ip both.
console (enable)>

Step 6 Enable ECLB.

console (enable)> set port channel slot_number/port_number mode on

Example

console (enable)> set port channel 1/7,7/7 mode on

For More Information

For the procedure for configuring inline VLAN pairs, see Configuring Inline VLAN Pairs, page 5-22.

Configuring ECLB in Inline Mode

For inline mode, add the single port 7 from each IDSM-2 to an EtherChannel and port 8 from each IDSM-2 to a different EtherChannel.

To configure the monitoring ports on IDSM-2 for ECLB in inline mode, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Configure each IDSM-2 for inline mode.

Step 4 Add the IDSM-2 monitoring port 7s to an EtherChannel.

console (enable)> set port channel slot_number/7 channel_A_number

Example

console (enable)> set port channel 1/7,7/7 1

Step 5 Enable ECLB for that EtherChannel.

console (enable)> set port channel slot_number/7 mode on

Example

console (enable)> set port channel 1/7,7/7 mode on

Step 6 Add the IDSM-2 monitoring port 8s to another EtherChannel.

console (enable)> set port channel slot_number/8 channel_B_number

Example

console (enable)> set port channel 1/8,7/8 2

Step 7 Enable ECLB for that EtherChannel.

console (enable)> set port channel slot_number/8 mode on

Example

console (enable)> set port channel 1/8,7/8 mode on

Step 8 Set the distribution method.

console (enable)> set port channel all distribution ip both
Channel distribution is set to ip both.
console (enable)>


For More Information

For the procedure for configuring inline VLAN pairs, see Configuring Inline VLAN Pairs, page 5-22.

Cisco IOS Software


Note IOS 12.2(18)SXF4 or later is required for inline mode.


This section describes how to enable ECLB for the three sensing modes in Cisco IOS software, and contains the following topics:

Restoring Defaults

Configuring ECLB in Promiscuous Mode

Configuring ECLB in Inline Mode

Configuring ECLB in Inline VLAN Pair Mode

Restoring Defaults

Use the intrusion-detection module module_number data-port {1 | 2} default command to restore the defaults to the specified data port. This command restores the following defaults: allowed VLANs, autostate, portfast, cost, and priority settings. If the data port belongs to a port channel, this command has no effect. This command is useful for clearing the data port before you add it to a port channel group.

This command is equivalent to using all of the following commands:

no intrusion-detection module module_number data-port {1 | 2} trunk allowed-vlan

intrusion-detection module module_number data-port {1 | 2} access vlan

intrusion-detection module module_number data-port {1 | 2} autostate include

intrusion-detection module module_number data-port {1 | 2} portfast

intrusion-detection module module_number data-port {1 | 2} spanning-tree cost

intrusion-detection module module_number data-port {1 | 2} spanning-tree priority

Configuring ECLB in Promiscuous Mode


Note For Cisco IOS version and supervisor requirements for EtherChannel load balancing on IDSM-2, see Table 20-1.



Note Cisco IOS supports promiscuous IDSM-2 EtherChannel using VACL capture (not SPAN or monitor).


An EtherChannel balances the traffic load across the links in an EtherChannel by reducing part of the binary pattern formed from the addresses in the frame to a numerical value that selects one of the links in the channel.

EtherChannel load balancing can use MAC addresses, IP addresses, or Layer 4 port numbers, which can be source or destination or both source and destination addresses or ports. The selected mode applies to all EtherChannels configured on the switch. ECLB can also use MPLS Layer 2 information.

Use the option that provides the balance criteria with the greatest variety in your configuration. For example, if the traffic on an EtherChannel is going only to a single MAC address and you use the destination MAC address as the basis of ECLB, the EtherChannel always chooses the same link in the EtherChannel; using source addresses or IP addresses might result in better load balancing.

To configure ECLB for promiscuous operation on IDSM-2, follow these steps:


Step 1 Configure each IDSM-2 for promiscuous operation.


Note Make sure that all IDSM-2 VACL capture or SPAN or monitor configuration lines have been removed before configuring ECLB for IDSM-2.


Step 2 Log in to the console.

Step 3 Enter global configuration mode:.

router# configure terminal 

Step 4 Create the VACL:.

router(config)# ip access-list extended vacl_name

Example

router(config)# ip access-list extended idstest

Step 5 Add any access control entries, for example, permit any any.

router(config-ext-nacl)# permit ip any any

Step 6 Create at least one VLAN access map sequence.

router(config-ext-nacl)# vlan access-map vlan_access_map_name sequence_number
router(config-access-map)# match ip address vacl_name
router(config-access-map)# action forward capture 

Example

router(config)# vlan access-map idstestmap 10
router(config-access-map)# match ip address idstest
router(config-access-map)# action forward capture

Step 7 Apply the VLAN access map to the VLAN(s).

router(config-access-map)# vlan filter vlan_access_map_name vlan-list vlan-list

Example

router(config)# vlan filter idstestmap vlan-list 50-60 

Step 8 For each IDSM-2, add the desired data ports into the desired EtherChannel.

router(config)# intrusion-detection module module_number data-port data_port_number 
channel-group channel_number

Example

router(config)# intrusion-detection module 13 data-port 1 channel-group 3
router(config)# intrusion-detection module 12 data-port 1 channel-group 3

Each EtherChannel has a numbered port channel interface. You can configure a maximum of 64 port channel interfaces, numbered from 1 to 256.

Step 9 Configure ECLB.

router(config)# port-channel load-balance src-dst-ip 

The default and only load balancing algorithm supported for IDSM-2 is src-dst-ip, which means EtherChannel uses the combination of source and destination IP addresses for its distribution method.

Step 10 Verify the load balancing.

router# show etherchannel load-balance
EtherChannel Load-Balancing Configuration:
        src-dst-ip

EtherChannel Load-Balancing Addresses Used Per-Protocol:
Non-IP: Source XOR Destination MAC address
  IPv4: Source XOR Destination IP address
  IPv6: Source XOR Destination IP address
  MPLS: Label or IP

Step 11 Set the VLANs to be captured to the EtherChannel.

router(config)# intrusion-detection port-channel channel_number capture allowed-vlan 
vlan_list

Example

router(config)# intrusion-detection port-channel 3 capture allowed-vlan 10

Step 12 Enable capture to the EtherChannel.
router(config)# intrusion-detection port-channel channel_number capture

Example

router(config)# intrusion-detection port-channel 3 capture

Step 13 Make sure autostate is included for the channel group.

router(config)# intrusion-detection port-channel channel_number autostate include

Example

router(config)# intrusion-detection port-channel 3 autostate include

This allows the switch virtual interface to stay up if the data port is the only port in the VLAN. The default is no include.

Step 14 (Optional) Enable portfast for the channel group.

router(config)# intrusion-detection port-channel channel_number portfast enable

Example

router(config)# intrusion-detection port-channel 3 portfast enable

The default is disabled.

Step 15 Exit global configuration mode.

router(config)# exit

Step 16 Save the changes.

router# write memory


For More Information

For more information on EtherChannel, refer to Catalyst 6500 Release 12.2SXF and Rebuilds Software Configuration Guide.

For more information on autostate and portfast, refer to Catalyst 6500 Series Software Configuration Guide, 8.x.

For the procedure for configuring IDSM-2 in promiscuous mode, see Configuring the Catalyst Series 6500 Switch for IDSM-2 in Promiscuous Mode.

Configuring ECLB in Inline Mode


Note Make sure that all IDSM-2 VACL capture or SPAN or monitor configuration lines have been removed before configuring ECLB for IDSM-2. You receive an error if you try to change the channel group to inline mode if you have capture enabled on any of the ports.


To configure ECLB for inline mode on IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal 

Step 3 For each IDSM-2, add all data port 1s into an EtherChannel.

router(config)# intrusion-detection module module_number data-port 1 port-channel 
channel_number

Example

router(config)# intrusion-detection module 1 data-port 1 port-channel 5

Each EtherChannel has a numbered port channel interface. You can configure a maximum of 64 port channel interfaces, numbered from 1 to 256. If the channel group and port channel have not been created, this command creates it with an empty allowed VLAN list. If the port channel exists, its allowed VLAN list, port fast, autostate, spanning tree cost, and priority settings are assigned to the data port.


Note You receive an error if you try to add a data port to a channel group that contains other port types or if you try to add another port type to a port channel containing one or more data ports.


Step 4 For each IDSM-2, add all data port 2s into a different EtherChannel.

router(config)# intrusion-detection module module_number data-port 2 port-channel 
channel_number

Example

router(config)# intrusion-detection module 1 data-port 2 port-channel 6

Step 5 Set the sensing mode to access (inline) and set the access VLAN for the channel group that contains the data port 1s.

router(config)# intrusion-detection port-channel channel_number access-vlan vlan_id

Example

router(config)# intrusion-detection port-channel 5 access-vlan 1050


Note You receive an error message if the port channel does not exist or if the port channel is already configured for trunk or capture mode. You must create the port channel or remove the port channel from trunk or capture mode.


Step 6 Set the sensing mode to access (inline) and set the access VLAN for the channel group that contains the data port 2s.

router(config)# intrusion-detection port-channel channel_number access-vlan vlan_id

Example

router(config)# intrusion-detection port-channel 6 access-vlan 10

Step 7 Configure ECLB.

router(config)# port-channel load-balance src-dst-ip

The default is src-dst-ip, which means EtherChannel uses the combination of source and destination IP addresses for its distribution method.

Example

router(config)# port-channel load-balance src-dst-ip

Step 8 Verify ECLB.

router# show etherchannel load-balance
EtherChannel Load-Balancing Configuration:
        src-dst-ip

EtherChannel Load-Balancing Addresses Used Per-Protocol:
Non-IP: Source XOR Destination MAC address
  IPv4: Source XOR Destination IP address
  IPv6: Source XOR Destination IP address
  MPLS: Label or IP

Step 9 For access (inline) mode, set autostate to include each channel group.

router(config)# intrusion-detection port-channel channel_number autostate include

Example

router(config)# intrusion-detection port-channel 5 autostate include

The default is no include. This prevents the switch virtual interface from going down if the data port is up and in the VLAN.

Step 10 (Optional) You can enable or disable portfast for each channel group.

router(config)# intrusion-detection port-channel channel_number portfast enable

Example

router(config)# intrusion-detection port-channel 5 portfast enable

The default is disabled.

Step 11 (Optional) Set the spanning tree path cost for each of the two channel groups.

router(config)# intrusion-detection port-channel channel_number spanning-tree cost 
port_cost

Example

router(config)# intrusion-detection port-channel 5 spanning-tree cost 4

Both channel groups must be set to the same port cost to make sure that data port 1 and data port 2 of each IDSM-2 are in the same state (forwarding versus blocking).

Step 12 (Optional) Set the spanning tree port priority for each of the two channel groups.

router(config)# intrusion-detection port-channel channel_number spanning-tree priority 
priority

Example

router(config)# intrusion-detection port-channel 5 spanning-tree priority 16

The possible port priority value is a multiple of 16 from 0 to 240. The default is 32.

Step 13 Exit global configuration mode.

router(config)# exit

Step 14 To save the changes.
router# write memory


For More Information

For more information on autostate, portfast, spanning tree and how to calculate the port cost, and port priority, refer to Catalyst 6500 Series Software Configuration Guide, 8.x.

For the procedure for configuring IDSM-2 in promiscuous mode, see Configuring the Catalyst Series 6500 Switch for IDSM-2 in Promiscuous Mode.

Configuring ECLB in Inline VLAN Pair Mode


Note Make sure that all IDSM-2 VACL capture or SPAN or monitor configuration lines have been removed before configuring ECLB for IDSM-2. You receive an error if you try to change the channel group to inline VLAN pair mode if you have capture enabled on any of the ports.


To configure ECLB for inline VLAN pair mode on IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal 

Step 3 Add the data port (either data port 1 or data port 2) from each IDSM-2 to the Etherchannel.

router(config)# intrusion-detection module module_number data-port [1:2] port-channel 
channel_number

Example

router(config)# intrusion-detection module 1 data-port 1 port-channel 5

Each EtherChannel has a numbered port channel interface. You can configure a maximum of 64 port channel interfaces, numbered from 1 to 256. If the channel group and port channel have not been created, this command creates it with an empty allowed VLAN list. If the port channel exists, its allowed VLAN list, port fast, autostate, spanning tree cost, and priority settings are assigned to the data port.


Note You receive an error if you try to add a data port to a channel group that contains other port types or if you try to add another port type to a port channel containing one or more data ports.


Step 4 Set the sensing mode to trunk (inline VLAN pair) and set the allowed VLANs for the channel group that contains the data port 1s. Determine which VLANs are going to be paired (100 and 200, 101 and 201) and set the allowed VLAN list to include all VLANs in all the pairs.

router(config)# intrusion-detection port-channel channel_number trunk allowed-vlan 
vlan_list

Example

router(config)# intrusion-detection port-channel 5 trunk allowed-vlans 100,101,200,201


Note The allowed VLAN list on the switch must include all VLANs that are paired as inline VLAN pairs on IDSM-2. Otherwise, traffic may be dropped.



Note You receive an error message if the port channel does not exist or if the port channel is already configured for trunk or capture mode. You must create the port channel or remove the port channel from trunk or capture mode.


Step 5 Configure ECLB.

router(config)# port-channel load-balance src-dst-ip 

The default is src-dst-ip, which means EtherChannel uses the combination of source and destination IP addresses for its distribution method.

Example

router(config)# port-channel load-balance src-dst-ip

Step 6 Verify ECLB.

router# show etherchannel load-balance
EtherChannel Load-Balancing Configuration:
        src-dst-ip

EtherChannel Load-Balancing Addresses Used Per-Protocol:
Non-IP: Source XOR Destination MAC address
  IPv4: Source XOR Destination IP address
  IPv6: Source XOR Destination IP address
  MPLS: Label or IP

Step 7 For access (inline) mode, set autostate to include the channel group.

router(config)# intrusion-detection port-channel channel_number autostate include

Example

router(config)# intrusion-detection port-channel 5 autostate include

The default is no include. This prevents the switch virtual interface from going down if the data port is up and in the VLAN.

Step 8 (Optional) You can enable or disable portfast for the channel group.

router(config)# intrusion-detection port-channel channel_number portfast enable

Example

router(config)# intrusion-detection port-channel 5 portfast enable

The default is disabled.

Step 9 (Optional) Set the spanning tree port cost for the channel group.

router(config)# intrusion-detection port-channel channel_number spanning-tree cost 
port_cost

Example

router(config)# intrusion-detection port-channel 5 spanning-tree cost 4

Step 10 (Optional) Set the spanning tree port priority for the channel group.
router(config)# intrusion-detection port-channel channel_number spanning-tree priority 
priority

Example

router(config)# intrusion-detection port-channel 5 spanning-tree priority 16

The possible port priority value is a multiple of 16 from 0 to 240. The default is 32.

Step 11 Exit global configuration mode.

router(config)# exit

Step 12 Save the changes.

router# write memory

Step 13 Pair the VLANs from Step 4 on IDSM-2.


For More Information

For more information on autostate, portfast, spanning tree and how to calculate the port cost, and port priority, refer to Catalyst 6500 Series Software Configuration Guide, 8.x.

For the procedure for pairing VLANs, see Configuring Inline VLAN Pairs, page 5-22.

Disabling ECLB

This section explains how to disable ECLB, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

To disable ECLB, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Disable ECLB for promiscuous or inline VLAN pair mode.

console (enable)> set port channel slot_number/port_number mode off

Example

console (enable)> set port channel 1/7,7/7 mode off

Step 4 Disable ECLB for inline mode.

a. Disable ECLB for one EtherChannel.

console (enable)> set port channel slot_number/7 mode off

Example

console (enable)> set port channel 1/7,7/7 mode off

b. Disable ECLB for the other EtherChannel.

console (enable)> set port channel slot_number/8 mode off

Example

console (enable)> set port channel 1/8,7/8 mode off


Cisco IOS Software

To disable ECLB for IDSM-2, follow these steps:


Step 1 Log in to the console.

Step 2 Enter global configuration mode.

router# configure terminal

Step 3 To remove a single IDSM-2 from the EtherChannel.

router(config)# no intrusion-detection module module_number data-port data_port_number 
channel-group channel_number 

Example

router(config)# no intrusion-detection module 1 data-port 1 channel-group 5 

Step 4 To remove the whole EtherChannel.

router(config)# no intrusion-detection module port-channel channel_number

Example

router(config)# no intrusion-detection module port-channel 5

Note The VACL capture commands for IDSM-2 are left.



Verifying ECLB

This section explains how to verify your ECLB configuration. It contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

To verify the ECLB configuration, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 View all EtherChannels.

console (enable)> show channel slot_number/port_number mode off

Example

console> (enable) show channel 
Channel Id   Ports
-----------  -----------------------------------------------
1669         1/7,7/7                                        
1698         2/1-6                                          
console> (enable)


Note In this output, an EtherChannel with ID 1669 is created to have two IDSM-2 data ports. Port 1/7 is for port 7 on the IDSM-2 in slot 1 while port 7/7 is for port 7 on the IDSM-2 in slot 7. Both IDSM-2s are configured for promiscuous operation. The switch load balances between each of the two IDSM-2 ports (one port on each IDSM-2).


Step 4 View specific EtherChannel status.

console (enable)> show channel hash channel_id source_ip_addr dest_ip_addr

Example

console> (enable) show channel hash 1669 10.20.2.1 10.20.5.3
Selected channel port: 1/7
console> (enable)

Note This output shows that traffic from 10.20.2.1 to 10.20.5.3 will be sent to port 1/7 (port 7 for the IDSM-2 in slot 1).



Cisco IOS Software

To verify the IDSM-2 ECLB configuration, follow these steps:


Step 1 Log in to the console.

Step 2 View all EtherChannels.

router# show etherchannel
                Channel-group listing:
                -----------------------

Group: 10
----------
Group state = L2
Ports: 0   Maxports = 8
Port-channels: 1 Max Port-channels = 1
Protocol:    -

router#

Step 3 View specific EtherChannel status.

router# show etherchannel 1 [summary | detail | port | port-channel | protocol]

Example

router# show etherchannel 1 summary
Flags:  D - down        P - in port-channel
        I - stand-alone s - suspended
        H - Hot-standby (LACP only)
        R - Layer3      S - Layer2
        U - in use      f - failed to allocate aggregator

        u - unsuitable for bundling
Number of channel-groups in use: 1
Number of aggregators:           1

Group  Port-channel  Protocol    Ports
------+-------------+-----------+----------------------------

router#

Step 4 View the ECLB setting.

router# show etherchannel load-balance
EtherChannel Load-Balancing Configuration:
        src-dst-ip
        mpls label-ip

EtherChannel Load-Balancing Addresses Used Per-Protocol:
Non-IP: Source XOR Destination MAC address
  IPv4: Source XOR Destination IP address
  IPv6: Source XOR Destination IP address
  MPLS: Label or IP
router#

Step 5 View IDSM-2 data port information.

router# show intrusion-detection module module_number data-port data_port_number state

Example

router# show intrusion-detection module 11 data-port 2 state
Intrusion-detection module 11 data-port 2:

Switchport: Enabled
Administrative Mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: Off
Access Mode VLAN: 662 (ward-victim3)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: NONE
Pruning VLANs Enabled: 2-1001
Vlans allowed on trunk:none
Vlans allowed and active in management domain: none
Vlans in spanning tree forwarding state and not pruned:
   none
Administrative Capture Mode: Disabled
Administrative Capture Allowed-vlans: empty


Administrative Tasks for IDSM-2

This section contains procedures that help you with administrative tasks for IDSM-2. It contains the following topics:

Enabling Full Memory Tests

Resetting IDSM-2

Enabling Full Memory Tests

When IDSM-2 initially boots, by default it runs a partial memory test. You can enable a full memory test in Catalyst software and Cisco IOS software. This section describes how to enable full memory tests, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

Use the set boot device boot_sequence module_number mem-test-full command to enable a full memory test. The full memory test takes about 12 minutes.

To enable a full memory test, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode:

console> enable

Step 3 Enable the full memory test.

console> (enable) set boot dev cf:1 3 mem-test-full
Device BOOT variable = cf:1
Memory-test set to FULL
Warning: Device list is not verified but still set in the boot string.
console> (enable) set boot dev hdd:1 3 mem-test-full
Device BOOT variable = hdd:1
Memory-test set to FULL
Warning: Device list is not verified but still set in the boot string.
console> (enable) 

The set boot device command can either contain cf:1 or hdd:1.

Step 4 Reset IDSM-2.

The full memory test runs.


Note A full memory test takes more time to complete than a partial memory test.



For More Information

For the procedure for resetting IDSM-2, see Resetting IDSM-2.

Cisco IOS Software

Use the hw-module module module_number reset mem-test-full command to enable a full memory test. The full memory test takes about 12 minutes.

To enable a full memory test, follow these steps:


Step 1 Log in to the console.

Step 2 Enable the full memory test.

router# hw-module module 9 reset mem-test-full
    Device BOOT variable for reset = <empty>
    Warning: Device list is not verified.

    Proceed with reload of module?[confirm]
    % reset issued for module 9
router#

Step 3 Reset IDSM-2.

The full memory test runs.


Note A full memory test takes more time to complete than a partial memory test.



For More Information

For the procedure for resetting IDSM-2, see Resetting IDSM-2.

Resetting IDSM-2

If for some reason you cannot communicate with IDSM-2 through SSH, Telnet, or the switch session command, you must reset IDSM-2 from the switch console. The reset process requires several minutes. This section describes how to reset IDSM-2, and contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

To reset IDSM-2 from the CLI, follow these steps:


Step 1 Log in to the console.

Step 2 Enter privileged mode.

console> enable

Step 3 Reset IDSM-2 to the application partition or the maintenance partition.

console> (enable) reset module_number [hdd:1 | cf:1]


Note If you do not specify either the application partition (hdd:1 the default) or the maintenance partition (cf:1), IDSM-2 uses the boot device variable.


Example

console> (enable) reset 3 
2003 Feb 01 00:18:23 %SYS-5-MOD_RESET: Module 3 reset from console// 
Resetting module 3... This may take several minutes. 
2003 Feb 01 00:20:03 %SYS-5-MOD_OK: Module 3 is online. 
console> (enable)


Caution If IDSM-2 is removed from the switch chassis without first being shut down, or the chassis loses power, you may need to reset IDSM-2 more than once. If IDSM-2 fails to respond after three reset attempts, boot the maintenance partition, and perform the instructions for restoring the application partition.


For More Information

For the procedure for reimaging IDSM-2, see Installing the IDSM-2 System Image, page 23-28.

Cisco IOS Software

Use the hw-module module slot_number reset [hdd:1 | cf:1] command in EXEC mode to reset IDSM-2. The reset process takes several minutes. IDSM-2 boots into the boot partition you specify. If you do not specify the boot string, the default boot string is used.

To reset IDSM-2 from the CLI, follow these steps:


Step 1 Log in to the console.

Step 2 Reset IDSM-2.

router# hw-module module module-number reset [hdd:1 | cf:1]


Note If you do not specify either the application partition (hdd:1 the default) or the maintenance partition (cf:1), IDSM-2 uses the boot device variable.


Example

router# hw-module module 8 reset
Device BOOT variable for reset = 
Warning: Device list is not verified. 
Proceed with reload of module? [confirm] 
% reset issued for module 8
router#


Catalyst and Cisco IOS Software Commands


Note For more detailed information on Catalyst and Cisco IOS software commands, refer to the command references found on Cisco.com. For instructions on how to locate these documents, refer to Documentation Roadmap for Cisco Intrusion Prevention System 6.2.


This section lists the Catalyst and Cisco IOS software commands that pertain to IDSM-2. It contains the following topics:

Catalyst Software

Cisco IOS Software

Catalyst Software

This section lists supported and unsupported Catalyst Software Commands. It contains the following topics:

Supported Supervisor Engine Commands

Unsupported Supervisor Engine Commands

Supported Supervisor Engine Commands

IDSM-2 also supports the following supervisor engine CLI commands, which are described in more detail in the Catalyst 6500 Series Command References.

clear config module_number

Clears the configuration on the supervisor engine that is associated with the specified IDSM-2.

clear log module_number

Deletes all entries in the error log for the specified IDSM-2.

session slot_number

Logs in to the console of IDSM-2 from the switch console.

set module commands (all other set module commands return an error message):

set module name module_number

Sets the name of the module.

set module power module_number [up | down]

Enables or disables power to the specified IDSM-2.

set port name module_number

Configures the name for the specified IDSM-2 port.

set span

Configures port 1 as a SPAN destination port. You cannot use port 1 on IDSM-2 as a SPAN source port.

set trunk

Configures trunk ports.

set vlan

Configures VLAN capture ports.

show config

Displays the supervisor engine NVRAM configurations.

show log

Displays the error logs for the specified IDSM-2.

show mac module_number

Displays the MAC counters for the specified IDSM-2.

show module module_number

With an IDSM-2 installed, displays Intrusion Detection System Module under Module-Type.

show port module_number

Displays the port status for the specified IDSM-2.

show port capabilities [module | module_number]

Displays the capabilities of the module and ports.

show test

Displays the errors reported from the diagnostic tests for both the SPAN port (port 1) and the management port (port 2) and the BIOS and CMOS boot results.

Unsupported Supervisor Engine Commands

The following supervisor engine CLI commands are not supported by IDSM-2:

set module [enable | disable] module_number

set port broadcast

set port channel

set port cops

set port disable

set port enable

set port flowcontrol

set port gmrp

set port gvrp

set port host

set port inlinepower

set port jumbo

set port membership

set port negotiation

set port protocol

set port qos

set port rsvp

set port security

set port speed

set port trap

set protocolfilter

set rgmp

set snmp

set spantree

set udld

set vtp

Cisco IOS Software

This section lists the Cisco IOS software commands that IDSM-2 supports. These commands are grouped according to mode. This section contains the following topics:

EXEC Commands

Configuration Commands

EXEC Commands

The following commands are all performed in EXEC mode:

clock read-calendar

Updates the clock time to the calendar time.

clock set time date

Sets the current time and date.

clock update-calendar

Updates the calendar time to the clock time.

hw-module module module_number reset [cf:1 | hdd:1]

Resets IDSM-2 into the partition specified by the boot device variable; if the boot device variable has not been set, IDSM-2 is reset to the application partition by default. Use the command show boot device module module_number to view the current setting of the boot device variable. cf:1 is the maintenance partition. hdd:1 is the application partition.

hw-module module module_number shutdown

Shuts down IDSM-2 so that it can be safely removed from the chassis.

reload

Reloads the entire switch.

session slot module_number processor processor_number

Logs in to the console of IDSM-2 from the switch console.

show boot device module module_number

Displays the current boot string for the specified module.

show diagnostic result module module_number

Displays the results of the online diagnostics that were performed when IDSM-2 was last booted up.

show interface port-channel channel_number

Displays the status of the port channel.

show intrusion-detection module module_number data-port {1 | 2} {state | traffic}

Displays the state or traffic statistics of the specified IDSM-2 data port.

show intrusion-detection module module_number management-port {state | traffic}

Displays the state or traffic statistics of the IDSM-2 management port.

show ip access-lists

Displays the current access lists.

show module [module_number | all | version]

Displays the installed modules, versions, and states.

show monitor session session_number

Displays the SPAN source and destination for the specified session.

show running-config

Displays the configuration that is currently running.

show spanning-tree active

Displays spanning tree state information for active interfaces only.

show spanning-tree detail

Displays detailed spanning tree state information.

show spanning-tree summary [totals]

Displays the high level state of spanning tree. Does not show interface specific information.

show spanning-tree vlan vlan_number

Displays spanning tree state information for the specified VLAN. Includes list of ports on which those VLANs are forwarded or blocked.

show startup-config

Displays the saved configuration.

show vlan access-map

Displays all current VLAN access maps.

Configuration Commands

The following configuration commands are all performed in either global configuration mode, interface configuration mode, or VACL configuration submode:

Global configuration mode

boot device module number_number {cf:1 | hdd:1}

Sets the default boot device for the specified module. cf:1 boots to the MP and hdd:1 boots to the AP. The no option clears the boot string, which sets the default boot device to the AP.

clock calendar valid

Sets the current calendar time as the switch time on bootup.

clock summer-time zone recurring

Sets the switch to use the summertime settings.

clock timezone zone offset

Sets the timezone for the switch/IDSM-2.

fabric switching-mode force busmode

Lets service modules that do not support packet recirculation, be forced into communicating through the chassis shared bus instead of the switched fabric. This forces the supervisor to handle the packet recirculation centrally and lets the service module communicate properly on VLANs meeting the conditions stated above. Other fabric enabled modules that are not affected by this problem continue to communicate through the switch fabric even if this command is enabled.

[no] intrusion-detection module module_number data-port {1 | 2} access vlan vlan_id

Sets the data port to access (inline) mode and sets the access VLAN for the data port for the specified module.

[no] intrusion-detection module module_number data-port {1 | 2} autostate include

Includes (or excludes) the specified data port in the autostate calculation. When included, the switch virtual interface associated with an MSFC or WLAN port remains up while the module's data port is enabled. When excluded, the switch virtual interface associated with the MSFC or WAN port goes down if the specified module's data port is the only active port in the VLAN. The default is no include.

[no] intrusion-detection module module_number data-port {1 | 2} capture

Configures the specified data port as a capture destination port. You must also set the allowed VLAN list through the intrusion-detection module module_number data-port {1 | 2} capture command before any packets are captured. The IDSM-2 must be in promiscuous mode.

[no] intrusion-detection module module_number data-port {1 | 2} capture allowed-vlan vlan_list

Sets the allowed VLANs on the specified data port for packet capture. You must also enable capture mode on the data port through the intrusion-detection module module_number data-port {1 | 2} capture command before traffic is captured on the data port.

intrusion-detection module module_number data-port {1 | 2} default

Restores the allowed VLANs, autostate, portfast, port cost, and priority settings for the specified data port to the default values. This command is useful to remove any configuration from a data port before you add it to a channel group.

[no] intrusion-detection module module_number data-port {1 | 2}port-channel channel_number

Adds the data port for the specified module to the channel group, which creates a port channel with the same numeric ID. If the channel group and port channel have not been created, this command creates it with an empty allowed VLAN list. The no option removes the data port from the channel group, restores the data port settings to their defaults, and deletes the port channel if it is empty.

[no] intrusion-detection module module_number data-port {1 | 2}portfast {enable | disable} [trunk]

Enables or disables portfast on the data port. When portfast is enabled, traffic is forwarded by the switch to the IDSM-2 data port while the spanning tree is being built. When disabled, traffic is inhibited until after the tree is built and the backplane port is in the forwarding state. The default is disabled. The trunk option enables or disables portfast when the data port is configured as a trunk (in promiscuous or inline VLAN pairs mode).

[no] intrusion-detection module module_number data-port {1 | 2} spanning-tree cost path_cost

Sets the spanning tree path cost for the data port on the specified module. The no option restores the spanning tree cost for the data port on the specified module to the default cost value.

[no] intrusion-detection module module_number data-port {1 | 2} trunk allowed-vlan vlan_list

Sets the data port to trunking mode and sets the list of allowed VLANs on the data port for the specified module. The no option removes the data port from trunking mode and clears the list of allowed VLANs on the data port for the specified module.

intrusion-detection module module_number management-port access-vlan vlan_number

Sets the access VLAN for the IDSM-2 command and control port.

intrusion-detection module module_number data-port data_port_number capture allowed-vlan allowed_capture_vlan(s)

Configures the VLAN(s) for VACL capture.

intrusion-detection module module_number data-port data_port_number capture

Enables VACL capture for the specified IDSM-2 data port.

[no] intrusion-detection port-channel channel_number access vlan vlan_id

Sets all data ports in the specified port channel to access mode and sets the access VLAN for the data ports. The no option clears the list of allowed VLANs on the data ports of all modules in the specified port channel.

[no] intrusion-detection port-channel channel_number autostate include

Includes or excludes all data ports in the specified port channel from the autostate calculation. When included, the virtual switch interface associated with an MSFC or WLAN port remains up while the data port is enabled. When excluded, the virtual switch interface associated with the MSFC or WAN port goes down if the data port is the only active port in the VLAN. The data ports are excluded from the autostate calculations by default.

[no] intrusion-detection port-channel channel_number capture

Configures all data ports in the channel group as capture ports. The no option disables the capture function on all data ports in the channel group.

[no] intrusion-detection port-channel channel_number capture allowed-vlan vlan_id

Sets the list of capture VLANs on the data ports of all modules in the specified port channel. This command does not set the channel group to capture mode. Use the intrusion-detection port-channel channel_number capture command to set the channel group to capture mode. The no option clears the list of capture VLANs on the data ports of all modules in the specified port channel.

[no] intrusion-detection port-channel channel_number portfast {enable | disable} [trunk]

Enables or disables portfast on the data ports in the port channel. When portfast is enabled, traffic is forwarded by the switch to the data port while the spanning tree is being built. When disabled, traffic is inhibited until after the tree is built and the backplane port is in the forwarding state. Use the trunk option to enable or disable portfast when the data port is configured as a trunk (in promiscuous or inline VLAN pair mode). Do not use the trunk option when the data ports are configured as access ports (inline mode). Portfast and portfast trunk are disabled by default.

[no] intrusion-detection port-channel channel_number spanning-tree cost port_cost

Sets the spanning tree port cost for the data port on the specified module. The no option restores the spanning tree port cost for the data port on the specified module to the default value.

[no] intrusion-detection port-channel channel_number spanning-tree priority priority

Sets the spanning tree port priority for the data port on the specified module. The no option restores the spanning tree port priority for the data port on the specified module to the default value.

[no] intrusion-detection port-channel channel_number trunk allowed-vlan vlan_id

Sets the list of allowed VLANs on the data ports of all modules in the specified port channel. The no option clears the list of allowed VLANs on the data ports of all modules in the specified port channel.

ip access-list extended word

Creates access lists for use in the VACL maps.

[no] monitor session session_number destination intrusion-detection module module_number data-port {1 | 2}

Configures a SPAN destination port, which can be either a standard line card port or an IDSM-2 data port.

[no] monitor session session_number {source {interface interface_number} | {vlan vlan_id}} [ , | - | rx | tx | both]

Sets the sources for a SPAN session.

[no] power enable module module_number

Powers IDSM-2 off or on.

[no] spanning tree mode {pvst | mst | rapid-pvst}

Selects the spanning tree protocol (PVST+, MST, or Rapid-PVST+) to be used globally on the switch. The default is PVST. MST is not supported for IDSM-2. The no option restores the spanning tree mode to the default.

vlan access-map map_name_sequence

Creates the VACL maps.

vlan filter map_name vlan-list vlans

Maps the VACL maps to VLANs.

Interface configuration mode

switchport

Sets the interface as a switch port.

switchport access vlan vlan

Sets the access VLAN for the interface.

switchport capture

Sets the interface as a capture port.

switchport mode access

Sets the interface as an access port.

switchport mode trunk

Sets the interface as a trunk port.

switchport trunk allowed vlan vlans

Sets the allowed VLANs for trunk.

switchport trunk encapsulation dot1q

Sets dot1q as the encapsulation type.

switchport trunk native vlan vlan

Sets the native VLAN for the trunk port.

VACL configuration submode

action forward capture

Designates that matched packets should be captured.

match ip address [1-199 | 1300-2699 | acl_name]

Specifies filtering in the VACL.