Table Of Contents
Preparing for Installation
Safety
Supported Line Cards on 7600 Chassis
Site Requirements
Preventing Electrostatic Discharge Damage
Environmental Requirements
Power Requirements
Power Connection Guidelines
AC-Powered Systems
AC Power Cord Illustrations
DC-Powered Systems
Site Planning Checklist
Preparing for Installation
Note
This publication describes the following Cisco 7600 series routers:
•
Cisco 7603 Router—CISCO7603
•
Cisco 7603-S Router—CISCO7603-S
•
Cisco 7604 Router—CISCO7604
•
Cisco 7606 Router—CISCO7606
•
Cisco 7606-S Router—CISCO7606-S
•
Cisco 7609 Router—CISCO7609
•
Cisco 7609-S Router—CISCO7609-S
•
Cisco 7613 Router—CISCO7613
Information on the Cisco 7609 Router (product number OSR-7609) is in the Cisco 7609 Router Installation Guide, located at this URL:
http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/osrouter/index.htm
This chapter describes how to prepare your site for Cisco 7600 series router installation and contains these sections:
•
Safety
•
This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
•
Power Connection Guidelines
•
Site Planning Checklist
For detailed information about module cabling requirements, see "Connector and Cable Specifications"
Safety
 |
Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.
|
 |
Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
|
 |
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
|
 |
Warning Read the installation instructions before connecting the system to the power source.
|
 |
Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations.
|
Supported Line Cards on 7600 Chassis
Table 2-1 List of Supported Line Cards on 7600 Chasis
Product
|
Product Description
|
7600-ES20-GE3C
|
7600 ES20 Line Card, 20xGE SFP with DFC 3C
|
7600-ES20-GE3CXL
|
7600 ES20 Line Card, 20xGE SFP with DFC 3CXL
|
7600-ES20-10G3C
|
7600 ES20 Line Card, 2x10GE XFP with DFC 3C
|
7600-ES20-10G3CXL
|
7600 ES20 Line Card, 2x10GE XFP with DFC 3CXL
|
7600-ES+20G3C
|
7600 ES+ Line Card, 20xGE SFP with DFC 3C
|
7600-ES+20G3CXL
|
7600 ES+ Line Card, 20xGE SFP with DFC 3CXL
|
7600-ES+2TG3C
|
7600 ES+ Line Card, 2x10GE XFP with DFC 3C
|
7600-ES+2TG3CXL
|
7600 ES+ Line Card, 2x10GE XFP with DFC 3CXL
|
7600-ES+40G3C
|
7600 ES+ Line Card, 40xGE SFP with DFC 3C
|
7600-ES+40G3CXL
|
7600 ES+ Line Card, 40xGE SFP with DFC 3CXL
|
7600-ES+4TG3C
|
7600 ES+ Line Card, 4x10GE XFP with DFC 3C
|
7600-ES+4TG3CXL
|
7600 ES+ Line Card, 4x10GE XFP with DFC 3CXL
|
7600-SIP-200
|
Cisco 7600 Series SPA Interface Processor-200
|
7600-SIP-400
|
Cisco 7600 Series SPA Interface Processor-400
|
7600-SIP-600
|
Cisco 7600 Series SPA Interface Processor-600
|
7600-SSC-400
|
Cisco 7600 / Catalyst 6500 Services SPA Carrier Card
|
WS-X6582-2PA
|
Cisco7600/Catalyst6500 Enhanced FlexWAN, Fabric-enabled
|
WS-X6548-GE-TX
|
Catalyst 6500 48-port fabric-enabled 10/100/1000 Module
|
WS-X6548-GE-45AF
|
Cat6500 48-port PoE 802.3af & ePoE 10/100/1000 CEF256 card
|
WS-X6408A-GBIC
|
Catalyst 6000 8-port GE, Enhanced QoS (Req. GBICs)
|
WS-X6196-RJ-21
|
Catalyst 6500 96-Port 10/100 Upgradable - PoE 802.3af
|
WS-X6196-21AF
|
Cat6500 96-Port, PoE 802.3af 10/100 - RJ-21
|
WS-X6148-RJ-45
|
Catalyst 6500 48-Port 10/100, Upgradable to Voice, RJ-45
|
WS-X6148-RJ-21
|
Catalyst 6500 48-Port 10/100 Upgradable to Voice, RJ-21
|
WS-X6148-GE-TX
|
Catalyst 6500 48-port 10/100/1000 GE Mod., RJ-45
|
WS-X6148-GE-45AF
|
Cat6500 48-Port PoE 802.3af & ePoE 10/100/1000 line card
|
WS-X6148-FE-SFP
|
Catalyst 6500 48 port 100Base-X module (require SFP)
|
WS-X6148A-RJ-45
|
Catalyst 6500 48-Port 10/100 w/TDR, Upgradable - PoE 802.3af
|
WS-X6148A-GE-TX
|
Catalyst 6500 48-port 10/100/1000 w/Jumbo Frame, RJ-45
|
WS-X6148A-GE-45AF
|
Cat6500 48-Port PoE 802.3af & ePoE 10/100/1000 w/Jumbo Frame
|
WS-X6148A-45AF
|
Catalyst 6500 48-Port PoE 802.3af 10/100,card w/TDR
|
WS-X6148-45AF
|
Catalyst 6500 PoE 802.3af 10/100, 48 port(RJ45) line card
|
WS-X6148-21AF
|
Cat6500 PoE 802.3af 10/100, 48 port (RJ21) line card
|
WS-X6516A-GBIC
|
Catalyst 6500 16-port GigE Mod, fabric-enabled (Req. GBICs)
|
WS-X6748-GE-TX
|
Cat6500 48-port 10/100/1000 GE Mod: fabric enabled, RJ-45
|
WS-X6724-SFP
|
Catalyst 6500 24-port GigE Mod: fabric-enabled (Req. SFPs)
|
WS-X6748-SFP
|
Catalyst 6500 48-port GigE Mod: fabric-enabled (Req. SFPs)
|
WS-X6704-10GE
|
Cat6500 4-port 10 Gigabit Ethernet Module (req. XENPAKs)
|
WS-X6708-10G-3C
|
C6K 8 port 10 Gigabit Ethernet module with DFC3C (req. X2)
|
WS-X6708-10G-3CXL
|
C6K 8 port 10 Gigabit Ethernet module with DFC3CXL (req. X2)
|
Site Requirements
This section provides site power requirements for the Cisco 7600 series routers. You should verify the site power prior to installing the router. Power requirements vary for each router; ensure that you verify the site power for the type of router you are installing.
For EMI recommendations, refer to the Site Preparation and Safety Guide.
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are improperly handled, results in complete or intermittent failures. Port adapters and processor modules consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI) shielding and connectors are integral components of the carrier. Although the metal carrier helps to protect the board from ESD, use a preventive antistatic strap during handling.
Following are guidelines for preventing ESD damage:
•
Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
•
Connect the equipment end of the strap to an unfinished chassis surface.
•
When installing a component, use any available ejector levers or captive installation screws toproperly seat the bus connectors in the backplane or midplane. These devices prevent accidentalremoval, provide proper grounding for the system, and help to ensure that bus connectors areproperly seated.
•
When removing a component, use any available ejector levers or captive installation screws to release the bus connectors from the backplane or midplane.
•
Handle carriers by available handles or edges only; avoid touching the printed circuit boards or connectors.
•
Place a removed component board-side-up on an antistatic surface or in a static shielding container. If you plan to return the component to the factory, immediately place it in a static shielding container.
•
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects components from ESD voltages on the body; ESD voltages on clothing can still cause damage.
•
Never attempt to remove the printed circuit board from the metal carrier.
Caution 
For safety, periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 megohm (Mohm).
Environmental Requirements
Insure adequate spacing between racks using the information in Table 2-2. Keep all of the vents clear of obstructions, including dust and foreign conductive material, and away from the exhaust ports of other equipment.
Table 2-2 Chassis Airfow Requirements
Chassis Model
|
Airflow Intake
|
Airflow Exhaust
|
Air Filter Option
|
Minimum Clearance (walls)
|
Minimum Horizontal Separation
|
CISCO7603 (Figure 1-14)
|
Right side
|
Left side
|
No
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7603-S (Figure 1-15)
|
Right side
|
Left side
|
No
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7604 (Figure 1-16)
|
Right side
|
Left side
|
No
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7606 (Figure 1-17)
|
Right side
|
Left side1
|
Yes
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7606-S (Figure 1-18)
|
Right side
|
Left side1
|
Yes
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7609 (Figure 1-19)
|
Front
|
Rear2
|
Yes
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7609-S (Figure 1-19)
|
Front
|
Rear2
|
Yes
|
6 in (15 cm)
|
12 in (30.5)
|
CISCO7613 (Figure 1-20)
|
Right side
|
Left side
|
No
|
6 in (15 cm)
|
12 in (30.5)
|
Heat dissipation is an important consideration for sizing the air-conditioning requirements for an installation. The power and heat associated with a Cisco 7600 series router varies based upon these considerations:
•
Power supply type
•
Module types and quantities
•
Average traffic levels
Unless otherwise noted, the information in Table 2-3 through Table 2-19 assumes worst-case conditions (with GBICs and port adapters installed, if applicable), so typical numbers are approximately 30 percent below the numbers listed here. See Table 2-20 for a sample calculation of a router configuration.
This section provides the power and heat numbers for the Cisco 7600 series chassis and modules. The following power requirements and heat dissipation tables are provided:
•
Chassis and fan trays—Table 2-3
•
Supervisor engines—Table 2-4
•
Policy Feature Cards (PFCs)—Table 2-5
•
Distributed Forwarding Cards (DFCs)—Table 2-6
•
Switch fabric modules—Table 2-7
•
10-Gigabit Ethernet modules—Table 2-8
•
Gigabit Ethernet modules—Table 2-9
•
10/100/1000 Ethernet modules—Table 2-10
•
Fast Ethernet switching modules—Table 2-11
•
10/100 Ethernet switching modules—Table 2-12
•
10BASE Ethernet switching modules—Table 2-13
•
FlexWAN and Enhanced FlexWAN modules—Table 2-14
•
Service modules—Table 2-15
•
SPA Interface Processors (SIPs)—Table 2-16
•
Ethernet service cards—Table 2-17
•
Optical service modules (OSMs)—Table 2-18
•
Miscellaneous cards—Table 2-19
Note
Module power is the output from the power supply (internal to the system). The AC-input power is the input from the outlet to the power supply. The percentage difference between the two values is the efficiency of the power supply.
Table 2-3 Power Requirements and Heat Dissipation—Chassis and Fan Trays
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
Cisco 7603 chassis
|
|
|
|
|
|
|
FAN-MOD-3 fan tray
|
0.80
|
34.00
|
43.00
|
145.00
|
46.00
|
156.00
|
FAN-MOD-3HS fan tray
|
2.98
|
125.16
|
156.45
|
534.28
|
168.23
|
574.49
|
Cisco 7604 chassis
|
|
|
|
|
|
|
FAN-MOD-4HS fan tray
|
2.29
|
96
|
120
|
411
|
129
|
441
|
Cisco 7606 chassis
|
|
|
|
|
|
|
FAN-MOD-6
|
1.05
|
44
|
55
|
188
|
59
|
202
|
Cisco 7606 chassis
|
|
|
|
|
|
|
FAN-MOD-6HS
|
4.29
|
180
|
225
|
769
|
242
|
827
|
Cisco 7606 chassis
|
|
|
|
|
|
|
FAN-MOD-6SHS
|
7.40
|
311
|
389
|
1327
|
418
|
1427
|
Cisco 7609 chassis
|
|
|
|
|
|
|
with tiered-speed redundant fans
|
11.5
|
483
|
604
|
2062
|
649
|
2217
|
Cisco 7609-S chassis
|
|
|
|
|
|
|
FAN-MOD-9SHS
|
7.00
|
294.00
|
368.00
|
1255.00
|
395.00
|
1349.00
|
Cisco 7613 chassis
|
|
|
|
|
|
|
WS-C6K-13SLOT-FAN2 fan tray
|
7.10
|
298.20
|
372.75
|
1272.94
|
400.81
|
1368.75
|

Note
The module power values are based on 42 VDC. Power is distributed to each slot in the chassis from the power supply's 42 VDC output. Each module has DC-to-DC power supplies that convert the 42 VDC into +2.5 VDC, +3.3 VDC, and +5 VDC to power the module. The 42 VDC is independent of the power supply's input voltage, either 110 VAC or 220 VAC.
Table 2-4 lists the power and the heat numbers for the supervisor engines.
Table 2-4 Power Requirements and Heat Dissipation—Supervisor Engines
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6K-S2-MSFC2 Supervisor Engine 2 with PFC2 and MSFC2 daughter cards
|
3.46
|
145.32
|
181.65
|
620.33
|
195.32
|
667.03
|
WS-X6K-S2U-MSFC2 Supervisor Engine 2 with PFC2 and MSFC2 daughter cards—Has 512 MB of DRAM
|
3.46
|
145.32
|
181.65
|
620.33
|
195.32
|
667.03
|
WS-SUP32-10GE-3B Supervisor Engine 32 with PFC3B and MSFC2A daughter cards
|
4.19
|
175.98
|
219.98
|
751.21
|
236.53
|
807.76
|
WS-SUP32-GE-3B Supervisor Engine 32 with PFC3B and MSFC2A daughter cards
|
3.69
|
154.98
|
193.73
|
661.57
|
208.31
|
711.37
|
WS-SUP720 Supervisor Engine 720 with PFC3A daughter card and integrated MSFC3 and switch fabric
|
7.50
|
315.0
|
393.75
|
1344.66
|
423.39
|
1445.87
|
WS-SUP720-3B Supervisor Engine 720 with PFC3B daughter card and integrated MSFC3 and switch fabric
|
6.72
|
282.24
|
350.80
|
1204.81
|
379.35
|
1295.5
|
WS-SUP720-3BXL Supervisor Engine 720 with PFC3BXL daughter card and integrated MSFC3 and switch fabric
|
7.82
|
328.44
|
410.55
|
1402.03
|
441.45
|
1507.56
|
RSP720-3C-GE
|
6.90
|
290
|
362.50
|
1237.93
|
389.78
|
1331.11
|
RSP720-3CXL-GE
|
8.10
|
340.20
|
425.25
|
1452.23
|
457.26
|
1561.54
|
RSP720-3C-10GE
|
8.80
|
370
|
462.50
|
1579.43
|
497.31
|
1698.31
|
RSP720-3CXL-10GE
|
10
|
420
|
525
|
1792.87
|
564.51
|
1927.82
|
Table 2-5 lists the power and the heat numbers for the Policy Feature Cards (PFCs).
Table 2-5 Power Requirements and Heat Dissipation—Policy Feature Cards (PFCs)
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-F6K-PFC3A Policy Feature Card 3A
|
2.25
|
94.50
|
118.13
|
403.40
|
127.02
|
433.76
|
WS-F6K-PFC3B Policy Feature Card 3B
|
1.47
|
61.74
|
77.18
|
263.55
|
82.98
|
283.39
|
WS-F6K-PFC3BXL Policy Feature Card 3BXL
|
2.57
|
107.94
|
134.93
|
460.77
|
145.08
|
495.45
|
VS-F6K-PFC3C Policy Feature Card 3C
|
1.90
|
79.80
|
99.75
|
340.65
|
107.26
|
366.29
|
VS-F6K-PFC3CXL Policy Feature Card 3CXL
|
2.50
|
105.00
|
131.25
|
448.22
|
141.13
|
481.96
|
Table 2-6 lists the power and the heat numbers for the Distributed Forwarding Cards (DFCs).
Table 2-6 Power Requirements and Heat Dissipation—Distributed Forwarding Cards (DFCs)
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-F6K-DFC Distributed Forwarding Card
|
2.10
|
88.20
|
110.25
|
376.50
|
118.55
|
404.84
|
WS-F6K-DFC3A Distributed Forwarding Card 3A
|
2.57
|
107.94
|
134.93
|
460.77
|
145.08
|
495.45
|
WS-F6K-DFC3B Distributed Forwarding Card 3B
|
1.67
|
70.14
|
87.68
|
299.41
|
94.27
|
321.95
|
WS-F6K-DFC3BXL Distributed Forwarding Card 3BXL
|
2.38
|
99.96
|
124.95
|
426.70
|
134.35
|
458.82
|
WS-F6700-CFC Centralized Forwarding Card
|
0.75
|
31.5
|
39.38
|
134.47
|
42.34
|
144.59
|
WS-F6700-DFC3A Distributed Forwarding Card 3A
|
3.00
|
126
|
157.5
|
537.86
|
169.35
|
578.35
|
WS-F6700-DFC3B Distributed Forwarding Card 3B
|
2.7
|
113.40
|
141.75
|
484.08
|
152.42
|
520.51
|
WS-F6700-DFC3BXL Distributed Forwarding Card 3BXL
|
3.3
|
138.60
|
173.25
|
591.65
|
186.29
|
636.18
|
WS-F6700-DFC3C Distributed Forwarding Card 3C for use on CEF720 modules. Supported only with Supervisor Engine 720 and Supervisor Engine 720-10GE
|
1.65
|
69.30
|
86.63
|
295.82
|
93.15
|
318.09
|
WS-F6700-DFC3CXL Distributed Forwarding Card 3CXL for use on CEF720 modules. Supported only with Supervisor Engine 720 and Supervisor Engine 720-10GE.
|
2.35
|
98.70
|
123.38
|
421.33
|
132.66
|
453.04
|
Table 2-7 lists the power and the heat numbers for the switch fabric modules.
Table 2-7 Power Requirements and Heat Dissipation—Switch Fabric Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-C6500-SFM Switch Fabric Module
|
2.79
|
117.18
|
146.5
|
500.2
|
157.5
|
537.86
|
WS-X6500-SFM2 Switch Fabric Module 2
|
3.09
|
129.78
|
162.23
|
554
|
174.4
|
595.7
|
Table 2-8 lists the power and the heat numbers for the 10-Gigabit Ethernet modules.
Note
For all WS-X67xx modules, the values shown are for the baseboard only. When the baseboard has a CFC or DFC3 daughter card installed, you must add the daughter card power to the baseboard power to get the total slot power. For all other modules that support a mandatory or optional daughter card, you must add the daughter card power to the baseboard power to get the total slot power.
Table 2-8 Power Requirements and Heat Dissipation—10-Gigabit Ethernet Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6502-10GE 2-port 10-Gigabit Ethernet module
|
3.30
|
138.60
|
173.25
|
591.65
|
186.29
|
636.18
|
WS-X6704-10GE 4-Port 10-Gigabit Ethernet module
|
6.28
|
263.76
|
329.70
|
1125.93
|
354.52
|
1210.67
|
WS-X6708-10G-3C 8-Port 10-Gigabit Ethernet module with WS-F6700-DFC3C daughter card.
|
10.58
|
444.36
|
555.45
|
1896.86
|
600.49
|
2050.66
|
WS-X6708-10G-3CXL 8-Port 10-Gigabit Ethernet module with WS-F6700-DFC3CXL daughter card.
|
11.28
|
473.76
|
592.20
|
2022.36
|
640.22
|
2186.34
|
Table 2-9 lists the power and the heat numbers for the Gigabit Ethernet modules.
Table 2-9 Power Requirements and Heat Dissipation—Gigabit Ethernet Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6316-GE-TX 16-port 1000BASE-T Gigabit Ethernet module
|
5.15
|
216.3
|
270.38
|
923.33
|
290.73
|
992.83
|
WS-X6408A-GBIC 8-port 1000BASE-X Gigabit Ethernet module
|
2.00
|
84.00
|
105.00
|
358.58
|
112.90
|
385.56
|
WS-X6416-GBIC 16-port 1000BASE-X Gigabit Ethernet module
|
2.81
|
118.02
|
147.53
|
503.8
|
158.63
|
541.72
|
WS-X6416-GE-MT 8-port 1000BASE-SX Gigabit Ethernet module
|
2.50
|
105.00
|
131.25
|
448.22
|
141.13
|
481.96
|
WS-X6516-GBIC 16-port 1000BASE-X Gigabit Ethernet module
|
3.40
|
142.80
|
178.50
|
609.58
|
191.94
|
655.46
|
WS-X6516A-GBIC 16-port 1000BASE-X Gigabit Ethernet module
|
3.62
|
152.04
|
190.05
|
649.02
|
204.35
|
697.87
|
WS-X6724-SFP 24-Port 1000BASE-X Ethernet module
|
2.23
|
99.66
|
117.08
|
399.81
|
125.89
|
429.90
|
WS-X6748-SFP 48-Port 1000BASE-X Ethernet module
|
5.32
|
223.44
|
279.30
|
953.81
|
300.32
|
1025.60
|
WS-X6816-GBIC 16-Port1000BASE-X Gigabit Ethernet module
|
3.84
|
161.28
|
201.60
|
688.46
|
216.77
|
740.28
|
Table 2-10 lists the power and the heat numbers for the 10/100/1000 Ethernet switching modules.
Table 2-10 Power Requirements and Heat Dissipation—10/100/1000 Ethernet Switching Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6148-GE-TX 48-port 10/100/1000 Ethernet module
|
2.47
|
104.0
|
130.0
|
443.0
|
139.0
|
476.0
|
WS-X6148V-GE-TX 48-port 10/100/1000 Ethernet module with WS-F6K-VPWR-GE PoE daughter card
|
2.89
|
121.38
|
151.72
|
518.14
|
163.15
|
557.14
|
WS-X6148-GE-45AF 48-port 10/100/1000 Ethernet module with WS-F6K-GE48-AF PoE daughter card
|
2.65
|
111.30
|
139.13
|
475.11
|
149.60
|
510.87
|
WS-X6148A-GE-TX 48-port 10/100/1000 Ethernet module
|
2.5
|
105.0
|
131.25
|
448.22
|
141.13
|
481.96
|
WS-X6148A-GE-45AF 48-port 10/100/1000 Ethernet module with WS-F6K-GE48-AF PoE daughter card
|
2.68
|
112.56
|
140.70
|
480.49
|
151.29
|
516.66
|
WS-X6516-GE-TX 16-port 10/100/1000 Ethernet module
|
3.45
|
144.90
|
181.13
|
618.54
|
194.76
|
665.10
|
WS-X6548-GE-TX 48-port 10/100/1000 Ethernet module
|
2.98
|
125.16
|
156.45
|
534.28
|
168.23
|
574.49
|
WS-X6548V-GE-TX 10/100/1000 Ethernet module with WS-F6K-VPWR-GE PoE daughter card
|
3.40
|
142.80
|
178.50
|
609.58
|
191.94
|
655.46
|
WS-X6548-GE-45AF 48-port 10/100/1000 Ethernet module with WS-F6K-GE48-AF PoE daughter card
|
3.16
|
132.72
|
165.90
|
566.55
|
178.39
|
609.19
|
WS-X6748-GE-TX 10/100/1000 Ethernet module
|
7.00
|
294.00
|
367.50
|
1255.01
|
395.16
|
1349.48
|
Table 2-11 lists the power and the heat numbers for the Fast Ethernet switching modules.
Table 2-11 Power Requirements and Heat Dissipation—Fast Ethernet Switching Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6148-FE-SFP 48-port 100BASE-X module
|
2.3
|
96.60
|
120.75
|
412.36
|
129.84
|
443.40
|
WS-X6224-100FX-MT 24-port 100BASE-FX Ethernet module, MMF
|
1.90
|
79.8
|
99.75
|
340.65
|
107.26
|
366.3
|
WS-X6324-100FX-MM 24-port 100BASE-FX Ethernet module, MMF
|
1.52
|
63.84
|
79.8
|
272.52
|
85.81
|
293.03
|
WS-X6324-100FX-SM 24-port 100BASE-FX Ethernet module, SMF
|
1.52
|
63.84
|
79.8
|
272.52
|
85.81
|
293.03
|
WS-X6524-100FX-MM 24-port 100BASE-FX Ethernet module
|
1.90
|
79.8
|
99.75
|
340.65
|
107.3
|
366.3
|
Table 2-12 lists the power and the heat numbers for the 10/100 Ethernet switching modules.
Table 2-12 Power Requirements and Heat Dissipation—10/100 Ethernet Switching Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6148-RJ-21 48-port 10/100 Ethernet module
|
2.39
|
100.38
|
125.48
|
428.5
|
134.92
|
460.75
|
WS-X6148-RJ21V 48-port 10/100 Ethernet module with WS-F6K-VPWR PoE daughter card
|
2.39
|
100.38
|
125.48
|
428.50
|
134.02
|
460.75
|
WS-X6148-21AF 48-port 10/100 Ethernet module with WS-F6K-FE48-AF PoE daughter card
|
2.57
|
107.94
|
134.93
|
460.77
|
145.08
|
495.45
|
WS-X6148-RJ-45 48-port 10/100 Ethernet module
|
2.39
|
100.38
|
125.48
|
428.50
|
134.92
|
460.75
|
WS-X6148-RJ45V 48-port 10/100 Ethernet module with WS-F6K-VPWR PoE daughter card
|
2.39
|
100.38
|
125.48
|
428.50
|
134.92
|
460.75
|
WS-X6148-45AF 48-port 10/100 Ethernet module with WS-F6K-FE48-AF PoE daughter card
|
2.57
|
107.94
|
134.93
|
460.77
|
145.08
|
495.45
|
WS-X6148A-RJ-45 48-port 10/100 Ethernet module
|
1.00
|
42.0
|
52.5
|
179.29
|
56.45
|
192.78
|
WS-X6148A-45AF 48-port 10/100 Ethernet module
|
2.57
|
107.94
|
134.93
|
460.77
|
145.08
|
495.45
|
WS-X6148X2-RJ-45 96-port 10/100 Ethernet module
|
2.65
|
111.30
|
139.13
|
475.11
|
149.60
|
510.87
|
WS-X6148X2-45AF 96-port 10/100 Ethernet module with WS-F6K-FE48X2-AF PoE daughter card
|
3.07
|
128.94
|
161.18
|
550.41
|
173.31
|
591.84
|
WS-X6196-RJ-21 96-port 10/100 Ethernet module
|
2.74
|
115.08
|
143.85
|
491.25
|
154.68
|
528.22
|
WS-X6196-21AF 96-port 10/100 Ethernet module with WS-F6K-FE48X2-AF PoE daughter card
|
3.16
|
132.72
|
165.90
|
566.55
|
178.39
|
609.19
|
WS-X6248A-TEL 48-port 10/100 Ethernet module (telco)
|
2.69
|
113
|
141.23
|
482.28
|
151.85
|
518.58
|
WS-X6348-RJ21V 48-port 10/100 Ethernet module with WS-F6K-VPWR PoE daughter card
|
2.39
|
100.38
|
125.48
|
428.5
|
134.92
|
460.75
|
WS-X6348-RJ-45 48-port 10/100 Ethernet module
|
2.39
|
100.38
|
125.48
|
428.5
|
134.92
|
460.75
|
WS-X6348-RJ-45V 48-port 10/100 Ethernet module with WS-F6K-VPWR PoE daughter card
|
2.39
|
100.38
|
125.48
|
428.5
|
134.92
|
460.75
|
WS-X6548-RJ-21 48-port 10/100 Ethernet module
|
2.90
|
121.80
|
152.25
|
519.93
|
163.71
|
559.07
|
WS-X6548-RJ-45 48-port 10/100 Ethernet module
|
2.90
|
121.80
|
152.25
|
519.93
|
163.71
|
559.07
|
Table 2-13 lists the power and the heat numbers for the 10BASE Ethernet switching modules.
Table 2-13 Power Requirements and Heat Dissipation—10BASE Ethernet Switching Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6024-10FL-MT 24-port 10BASE-FL Ethernet module
|
1.52
|
63.84
|
79.8
|
272.52
|
85.81
|
293.0
|
Table 2-14 lists the power and the heat numbers for the FlexWAN and the enhanced FlexWAN modules.
Table 2-14 Power Requirements and Heat Dissipation—FlexWAN and Enhanced FlexWAN Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6182-2PA FlexWAN module
|
2.38
|
99.96
|
125
|
426.7
|
134.35
|
458.82
|
WS-X6582-2PA Enhance FlexWAN module
|
2.50
|
105.00
|
131.25
|
448.22
|
141.13
|
481.96
|
Table 2-15 lists the power and the heat numbers for the available service modules.
Table 2-15 Power Requirements and Heat Dissipation—Service Modules
Model Number/ Module Type
|
Module Current (A)
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
ACE10-6500-K9 Applications Control Engine (ACE) module
|
5.23
|
219.66
|
274.58
|
937.67
|
295.24
|
1008.25
|
WS-SVC-ADM-1-K9 Traffic Anomaly Detector Module
|
4.00
|
168.00
|
210.00
|
717.15
|
225.81
|
771.13
|
WS-SVC-AGM-1-K9 Anomaly Guard Module
|
4.00
|
168.00
|
210.00
|
717.15
|
225.81
|
771.13
|
WS-SVC-AON-1-K9 Application-Oriented Networking (AON) module
|
4.00
|
168.00
|
210.00
|
717.15
|
225.81
|
771.31
|
WS-SVC-CMM Communications Media Module
|
6.00
|
252.0
|
315.0
|
1075.73
|
338.71
|
1156.69
|
WS-SVC-CSG-1 Content Services Gateway module
|
3.00
|
126.0
|
157.5
|
537.86
|
169.35
|
578.35
|
WS-SVC-FWM-1-K9 Firewall Services Module
|
4.09
|
171.78
|
214.73
|
733.29
|
230.89
|
788.48
|
WS-SVC-IDSM2-K9 Intrusion Detection System Module 2
|
2.50
|
105.00
|
131.25
|
448.22
|
141.13
|
481.96
|
WS-SVC-IPSEC-1 IPSec VPN Services module
|
1.89
|
79.38
|
99.23
|
338.85
|
106.69
|
364.36
|
WS-SVC-MWAM-1 Multiprocessor WAN Application Module
|
3.57
|
149.94
|
187.43
|
640.06
|
201.53
|
688.23
|
WS-SVC-NAM-1 Network Analysis Module 1
|
2.89
|
121.38
|
151.73
|
518.14
|
163.15
|
557.14
|
WS-SVC-NAM-2 Network Analysis Module 2
|
3.47
|
145.74
|
182.18
|
622.13
|
195.89
|
668.95
|
WS-SVC-PSD-1 Persistent Storage Device module
|
4.00
|
168.0
|
210.0
|
717.15
|
225.81
|
771.13
|
WS-SVC-WEBVPN-K9 WebVPN Services module
|
2.94
|
123.48
|
154.35
|
527.11
|
165.97
|
566.78
|
WS-SVC-WISM-1-K9 Wireless Services Module (WiSM)
|
6.07
|
254.94
|
318.68
|
1088.25
|
342.66
|
1170.19
|
WS-SVC-WLAN-1-K9 Wireless LAN Services module
|
3.10
|
130.20
|
162.75
|
555.79
|
175.0
|
597.63
|
WS-X6066-SLB-S-K9 Content Switching module with SSL
|
2.15
|
90.30
|
112.88
|
385.47
|
121.37
|
414.48
|
Table 2-16 lists the power and the heat numbers for SIP modules.
Table 2-16 Power Requirements and Heat Dissipation—SIPs
Model Number/ Module Type
|
Module Current (A) @ 42 VDC
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
7600-SIP-200
|
5.69
|
239
|
299
|
1021
|
322
|
1100
|
7600-SIP-400
|
5.95
|
250
|
312
|
1065
|
338
|
1154
|
7600-SIP-600
|
6.42
|
270
|
338
|
1153
|
363
|
1240
|
Table 2-17 lists the power and the heat numbers for Ethernet Services modules.
Table 2-17 Power Requirements and Heat Dissipation—Ethernet Services
Model Number/ Module Type
|
Module Current (A) @ 42 VDC
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
7600-ES20-10G3CXL
|
8.11
|
341
|
426
|
1454
|
458
|
1563
|
7600-ES20-10G3C
|
8.11
|
341
|
426
|
1454
|
458
|
1563
|
7600-ES20-GE3CXL
|
8.11
|
341
|
426
|
1454
|
458
|
1563
|
7600-ES20-GE3C
|
8.11
|
341
|
426
|
1454
|
458
|
1563
|
7600-ES+2TGCXL
|
7.06
|
297
|
371.25
|
1267.81
|
399.19
|
1363.24
|
7600-ES+2TG3C
|
6.38
|
268
|
335
|
1144.02
|
360.21
|
1230.13
|
7600-ES+4TGCXL
|
9.49
|
399
|
498.75
|
1703.23
|
536.29
|
1831.43
|
7600-ES+4TG3C
|
8.82
|
370
|
362
|
1236.23
|
497.31
|
1698.31
|
7600-ES+40G3C
|
9.3
|
391
|
488.75
|
1669.08
|
122.31
|
417.69
|
7600-ES+20G3CXL
|
7.25
|
305
|
381.25
|
1301.96
|
409.94
|
1399.96
|
7600-ES+20G3C
|
6.58
|
276
|
345
|
1178.17
|
370.96
|
1266.85
|
7600-ES+40G3CXL
|
9.97
|
419
|
523.75
|
1788.60
|
563.17
|
1923.23
|
Table 2-18 lists the power and the heat numbers for Optical Service modules (OSMs).
Table 2-18 Power Requirements and Heat Dissipation—OSMs
Model Number/ Module Type
|
Module Current (A) @ 42 VDC
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
OSM-2OC12-POS-MM, -SI, -SL OC-12 POS, 2-port
|
3.35
|
141
|
176
|
602
|
190
|
648
|
OSM-2OC12-POS-MM+, -SI+ OC-12 POS, 2-port
|
3.35
|
141
|
176
|
816
|
190
|
648
|
OSM-4OC12-POS-MM, -SI, -SL OC-12 POS, 4-port
|
4.78
|
201
|
251
|
857
|
270
|
921
|
OSM-4OC12-POS-SI+ OC-12 POS, 4-port
|
4.54
|
191
|
239
|
816
|
257
|
877
|
OSM-4OC3-POS-SI OC-3 POS, 4-port
|
2.42
|
102
|
128
|
437
|
138
|
4.70
|
OSM-4OC3-POS-SI+ OC-3 POS, 4-port
|
2.42
|
102
|
128
|
437
|
138
|
4.70
|
OSM-8OC3-POS-SI, -SL OC-3 POS, 8-port
|
3.57
|
150
|
187
|
640
|
202
|
688
|
OSM-8OC3-POS-SI+, -SL+ OC-3 POS, 8-port
|
3.57
|
150
|
187
|
640
|
202
|
688
|
OSM-16OC3-POS-SI, -SL OC-3 POS, 16-port
|
5.09
|
214
|
267
|
913
|
287
|
981
|
OSM-16OC3-POS-SI+ OC-3 POS, 16-port
|
4.83
|
203
|
254
|
868
|
271
|
925
|
OSM-2OC12-ATM-MM, -SI OC-12 ATM, 2-port
|
3.61
|
152
|
190
|
649
|
204
|
698
|
OSM-2OC12-ATM-MM+, -SI+ OC-12 ATM, 2-port
|
4.00
|
168
|
210
|
717
|
226
|
771
|
OSM-1OC48-POS-SS, -SI, -SL OC-48 POS, 1-port
|
4.26
|
179
|
223
|
762
|
240
|
819
|
OSM-1OC48-POS-SS+, -SI+, -SL+ OC-48 POS, 1-port
|
3.90
|
164
|
205
|
699
|
220
|
752
|
OSM-12CT3/DS0 Channelized T-3 to DS-0, 12-port
|
2.80
|
118
|
147
|
502
|
158
|
540
|
OSM-1CHOC12/T1-SI Channelized OC-12/STM-4 to DS-0, 1 port
|
2.80
|
118
|
147
|
502
|
158
|
540
|
OSM-1CHOC12/T3-SI Channelized OC-12, 1-port
|
3.76
|
158
|
231
|
789
|
248
|
848
|
OSM-1CHOC48/T3-SS Channelized OC-48, 1-port
|
5.76
|
242
|
197
|
672
|
212
|
723
|
OSM-2OC48/1DPT-SS, -SI, -SL OC-48 DPT1 /POS, 2-ports
|
3.59
|
151
|
302
|
1031
|
325
|
1108
|
OSM-4GE-WAN-GBIC2 Gigabit Ethernet WAN Services Module, 4-port
|
5.07
|
213
|
188
|
644
|
203
|
692
|
OSM-2+4GE-WAN+ Gigabit Ethernet WAN Services Module, 2+4-port
|
3.76
|
158
|
267
|
911
|
287
|
979
|
Table 2-19 lists the power and the heat numbers for miscellaneous modules.
Table 2-19 Power Requirements and Heat Dissipation—Miscellaneous Modules
Model Number/ Module Type
|
Module Current (A) @ 42 VDC
|
Module Power (Watts)
|
AC
|
DC
|
AC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
DC-Input Power (Watts)
|
Heat Diss. (BTU/HR)
|
WS-X6066-SLB-APC Content Switching Module
|
3.0
|
126.0
|
157.5
|
537.9
|
169.35
|
578.35
|
Table 2-20 provides a sample calculation of power and heat dissipation for the following router configuration:
•
Cisco 7603 Router chassis (including AC-input power supplies)
•
One WS-X6K-S2U-MSFC2 supervisor engine
•
Two 4-port OC-12 POS modules
Table 2-20 Sample Calculation of Router Configuration
Model Number/ Module Type
|
AC-Input Power (Watts)
|
DC-Output Power (Watts)
|
Heat Diss. (BTU/HR)
|
Input Current
|
90 VAC (Amps)
|
120 VAC (Amps)
|
180 VAC (Amps)
|
240 VAC (Amps)
|
Cisco 7603 Router chassis (with fans)
|
88
|
34
|
302
|
0.98
|
0.74
|
0.49
|
0.37
|
WS-X6K-S2U-MSFC2
|
182
|
145
|
620
|
2.02
|
1.57
|
1.01
|
0.76
|
OSM-4OC12-POS-MM OC-12 module 4-port
|
502
|
402
|
1714
|
5.58
|
4.18
|
2.78
|
2.10
|
Total
|
751
|
565
|
2565
|
8.35
|
6.26
|
4.16
|
3.14
|
Power Requirements
 |
Warning Read the installation instructions before connecting the system to the power source.
|
Follow these requirements when preparing your site for the router installation:
•
The redundant power option provides a second, identical power supply to ensure that power to the chassis continues uninterrupted if one power supply fails or input power on one line fails.
•
In systems configured with the redundant power option, connect each of the two power supplies to a separate input power source. If you fail to do this, your system might be susceptible to total power failure due to a fault in the external wiring or a tripped circuit breaker.
•
To prevent a loss of input power, be sure that the total maximum load on each circuit supplying the power supplies is within the current ratings of the wiring and breakers.
•
In some systems, you might use an uninterruptible power supply (UPS) to protect against power failures at your site. Avoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems like the Cisco 7600 series router, which can have substantial current draw fluctuations due to bursty data traffic patterns.
Use the information in Table 2-3 through Table 2-19 to estimate the power requirements and heat dissipation of a Cisco 7600 series router based on a given configuration of the router. Table 2-20 provides a sample calculation. Determining power requirements might be useful for planning the power distribution system needed to support the router.
Power Connection Guidelines
This section provides the guidelines for connecting the Cisco 7600 series router AC and DC power supplies to the site power source.
AC-Powered Systems
Basic guidelines for AC-powered systems include the following:
•
Each chassis power supply should have its own dedicated branch circuit.
•
The circuit must be protected by a dedicated two-pole circuit breaker. For North America, the circuit breaker should be rated as follows:
–
15A for the 950 W power supply
–
15A or 20A for the 1400 W power supply
–
20A for the 1900 W power supply
–
20A for the 2700 W power supply
–
20A for the 3000 W power supply
–
30A for the 4000 W power supply.
–
20A for the 6000 W power supply (one for each of two inputs)
For everywhere else, the circuit breaker should be sized according to the power supply input rating and local or national code requirements.
•
The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment.
 |
Warning Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available.
|
 |
Warning The plug-socket combination must be accessible at all times because it serves as the main disconnecting device.
|
 |
Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations.
|
Table 2-21 lists the AC-input power cord options, specifications, and Cisco product numbers for the 950 W, 1400 W, 1900 W, 3000 W, 4000 W, and the 6000 W AC-input power supplies. Table 2-21 also references power cord illustrations.
Table 2-21 AC-Input Power Cord Options
Locale
|
Part Number
|
Length
|
Plug Rating
|
Power Cord Reference Illustration
|
950 W Power Supply (PWR-950-AC=)
|
North America
|
CAB-AC15A-90L-US(=)
|
8 feet (2.5m)
|
125VAC, 15A
|
Figure 2-1
|
Europe
|
CAB-AC10A-90L-EU(=)
|
8 feet (2.5m)
|
250VAC, 10A
|
Figure 2-2
|
United Kingdom
|
CAB-AC10A-90L-UK(=)
|
8 feet (2.5m)
|
250VAC, 10A
|
Figure 2-3
|
Italy
|
CAB-AC10A-90L-IT(=)
|
8 feet (2.5m)
|
250VAC, 10A
|
Figure 2-4
|
Australia
|
CAB-AC10A-90L-AU(=)
|
8 feet (2.5m)
|
250VAC, 10A
|
Figure 2-5
|
1400 W Power Supply (PWR-1400-AC=)
|
Argentina
|
CAB-7513ACR=
|
14 feet (4.3 m)
|
10 A, 250 VAC
|
Figure 2-6
|
Australia, New Zealand
|
CAB-7513ACA=
|
14 feet (4.3 m)
|
15 A, 250 VAC
|
Figure 2-7
|
Continental Europe
|
CAB-7513ACE=
CAB-2500W-EU=
|
14 feet (4.3 m)
|
16 A, 250 VAC
16 A, 250 VAC
|
Figure 2-8'
Figure 2-9
|
International
|
CAB-AC-2500W-INT
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-10
|
Italy
|
CAB-7513ACI=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-11
|
Japan, North America
|
CAB-7513AC=
CAB-AC-2500W-US1=
CAB-AC-C6K-TWLK=
|
14 feet (4.3 m)
|
20 A, 125 VAC
16 A, 250 VAC
16 A, 250 VAC
|
Figure 2-12
Figure 2-19
Figure 2-13
|
South Africa
|
CAB-7513ACSA=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-14
|
Switzerland
|
CAB-ACS-16=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-15
|
Switzerland
|
CAB-ACS-10=
|
7 feet (2.3 m)
|
10 A, 250 VAC
|
Figure 2-22
|
United Kingdom
|
CAB-7513ACU=
|
14 feet (4.3 m)
|
13 A, 250 VAC
|
Figure 2-16
|
China
|
CAB-AC16A-CH
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-23
|
1900 W Power Supply (PWR-1900-AC/6=)
|
North America (locking)
|
CAB-GSR16-US(=)
|
14 feet (4.3m)
|
250VAC, 20A
|
Figure 2-17
|
Europe
|
CAB-GSR16-EU(=)
|
14 feet (4.3m)
|
250VAC, 16A
|
Figure 2-17
|
International
|
CAB-AC16A-90L-IN(=)
|
14 feet (4.3m)
|
250VAC, 16A
|
Figure 2-17
|
2700 W Power Supply (PWR-2700-AC)
|
North America (locking)
|
CAB-GSR16-US(=)
|
14 feet (4.3m)
|
250VAC, 20A
|
Figure 2-17
|
Europe
|
CAB-GSR16-EU(=)
|
14 feet (4.3m)
|
250VAC, 16A
|
Figure 2-17
|
International
|
CAB-AC16A-90L-IN(=)
|
14 feet (4.3m)
|
250VAC, 16A
|
Figure 2-17
|
China
|
CAB-AC16A-CH=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-23
|
Continental Europe
|
CAB-AC-2500W-EU=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-18
|
International
|
CAB-AC-2500W-INT=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-10
|
Israel
|
CAB-AC-2500W-ISRL=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-24
|
Japan, North America (nonlocking plug) 200-240VAC operation
|
CAB-AC-2500W-US1=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-19
|
Japan, North America (locking plug) 200-240VAC operation
|
CAB-AC-C6K-TWLK=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-13
|
Japan, North America 100-120VAC operation1
|
CAB-7513AC=
|
14 feet (4.3 m)
|
20 A, 125 VAC
|
Figure 2-12
|
South Africa
|
CAB-7513ACSA=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-14
|
Switzerland
|
CAB-ACS-16=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-15
|
Australia, New Zealand
|
CAB-AC-16A-AUS=
|
14 feet (4.3 m)
|
16A,250 VAC
|
Figure 2-25
|
Power Distribution Unit (PDU(=) 2
|
CAB-C19-CBN
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-26
|
3000 W Power Supply (WS-CAC-3000W)
|
|
Continental Europe
|
CAB-AC-2500W-EU=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-18
|
International
|
CAB-AC-2500W-INT=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-10
|
Japan, North America (nonlocking plug) 200-240VAC operation
|
CAB-AC-2500W-US1=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-19
|
Japan, North America (locking plug) 200-240VAC operation
|
CAB-AC-C6K-TWLK=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-13
|
Japan, North America 100-120VAC operation3
|
CAB-7513AC=
|
14 feet (4.3 m)
|
20 A, 125 VAC
|
Figure 2-12
|
Switzerland
|
CAB-ACS-16=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-15
|
China
|
CAB-AC16A-CH=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-23
|
Australia, New Zealand
|
CAB-AC-16A-AUS=
|
14 feet (4.3 m)
|
16A,250 VAC
|
Figure 2-25
|
4000 W Power Supply
|
North America
|
WS-CAC-4000W-US=
|
12 feet (3.6m)
|
250VAC, 30A
|
Figure 2-20
|
International
|
WS-CAC-4000W-INT=
|
12 feet (3.6m)
|
250VAC, 30A
|
Figure 2-21
|
6000 W Power Supply
|
People's Republic of China
|
CAB-AC16A-CH=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-23
|
Continental Europe
|
CAB-AC-2500W-EU=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-18
|
International
|
CAB-AC-2500W-INT=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-10
|
Israel
|
CAB-AC-2500W-ISRL=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-24
|
Japan, North America (nonlocking plug) 200-240VAC operation
|
CAB-AC-2500W-US1=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-19
|
Japan, North America (locking plug) 200-240VAC operation
|
CAB-AC-C6K-TWLK=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-13
|
Japan, North America 100-120 VAC 4
|
CAB-7513AC= 4
|
14 feet (4.3 m)
|
20 A, 125 VAC
|
Figure 2-12
|
Switzerland
|
CAB-ACS-16=
|
14 feet (4.3 m)
|
16 A, 250 VAC
|
Figure 2-15
|
Australia, New Zealand
|
CAB-AC-16A-AUS=
|
14 feet (4.3 m)
|
16A,250 VAC
|
Figure 2-25
|
AC Power Cord Illustrations
This section contains the AC power cord illustrations. Note that an AC power cord may be used with several power supplies. See the power supply specifications tables for the correct AC power cord illustrations for your power supply.
Figure 2-1 CAB-AC15A-90L-US(=)
Figure 2-2 CAB-AC10A-90L-EU(=)
Figure 2-3 CAB-AC10A-90L-UK(=)
Figure 2-4 CAB-AC10A-90L-IT(=)
Figure 2-5 CAB-AC10A-90L-AU(=)
Figure 2-6 CAB-7513ACR=
Figure 2-7 CAB-7513ACA=
Figure 2-8 CAB-7513ACE=
Figure 2-9 CAB-2500W-EU=
Figure 2-10 CAB-AC-2500W-INT=
Figure 2-11 CAB-7513ACI=
Figure 2-12 CAB-7513AC=
Figure 2-13 CAB-AC-C6K-TWLK=
Figure 2-14 CAB-7513ACSA=
Figure 2-15 CAB-ACS-16=
Figure 2-16 CAB-7513ACU=
Figure 2-17 AC Power Cord Plugs and Appliance Coupler for the 1900 W Power Supply
Figure 2-18 CAB-AC-2500W-EU=
Figure 2-19 CAB-AC-2500W-US1=
Figure 2-20 WS-CAC-4000W-US=
Figure 2-21 WS-CAC-4000W-INT=
Figure 2-22 CAB-ACS-10=
Figure 2-23 CAB-AC16A-CH=
Figure 2-24 CAB-AC-2500W-ISRL=
Figure 2-25 CAB-AC-16A-AUS
Figure 2-26 CAB-C19-CBN
DC-Powered Systems
Basic guidelines for DC-powered systems include the following:
•
Each chassis power supply should have its own dedicated input power source. The source must comply with the safety extra-low voltage (SELV) requirements in the UL 60950, CSA 60950, EN 60950, IEC 60950 standards.
•
The circuit must be protected by a dedicated two-pole circuit breaker. The circuit breaker should be sized according to the power supply input rating and local or national code requirements.
•
The circuit breaker is considered the disconnect device and should be easily accessible.
•
The system ground is the power supply and chassis ground.
Caution 
Do not connect the DC-return wire to the system frame or to the system grounding equipment.
Site Planning Checklist
Table 2-22 lists the site planning activities that you should perform prior to installing the Cisco 7600 series router. Completing each activity helps ensure a successful router installation.
Table 2-22 Site Planning Checklist
Task No.
|
Planning Activity
|
Verified By
|
Time
|
Date
|
1
|
Space evaluation:
Space and layout Floor covering Impact and vibration Lighting Maintenance access
|
|
|
|
2
|
Environmental evaluation:
Ambient temperature Humidity Altitude Atmospheric contamination Airflow
|
|
|
|
3
|
Power evaluation:
Input power type Power receptacles (15A/20A/30A)) Receptacle proximity to the equipment Dedicated (separate) circuits for redundant power supplies UPS for power failures DC systems: Proper gauge wire and lugs
|
|
|
|
4
|
Grounding evaluation:
Circuit breaker size CO ground (AC- and DC-powered systems)
|
|
|
|
5
|
Cable and interface equipment evaluation:
Cable type Connector type Cable distance limitations Interface equipment (transceivers)
|
|
|
|
6
|
EMI evaluation:
Distance limitations for signaling Site wiring RFI levels
|
|
|
|