- Preface
- Cisco ONS Documentation Roadmap for Release 9.2.1
- Chapter 1, Install the Shelf and Backplane Cable
- Chapter 2, Install Cards and Fiber-Optic Cable
- Chapter 3, Connect the PC and Log Into the GUI
- Chapter 4, Turn Up a Node
- Chapter 5, Turn Up a Network
- Chapter 6, Create Circuits and VT Tunnels
- Chapter 7, Manage Circuits
- Chapter 8, Manage Alarms
- Chapter 9, Monitor Performance
- Chapter 10, Change Card Settings
- Chapter 11, Change Node Settings
- Chapter 12, Upgrade Cards and Spans
- Chapter 13, Upgrade Network and Configurations
- Chapter 14, Add and Remove Nodes
- Chapter 15, Maintain the Node
- Chapter 16, Power Down the Node
- Chapter 17, DLPs A1 to A99
- Chapter 18, DLPs A100 to A199
- Chapter 19, DLPs A200 to A299
- Chapter 20, DLPs A300 to A399
- Chapter 21, DLPs A400 to A499
- Chapter 22, DLPs A500 to A599
- Chapter 23, DLPs A600 to A699
- Appendix A, CTC Information and Shortcuts
Change Card Settings
This chapter explains how to change line provisioning, thresholds, service states, and line rates on Cisco ONS 15454 cards.
Before You Begin
Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide as necessary.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1.
A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards—As needed, complete this procedure to change line and threshold settings for all electrical cards (EC-1, DS-1, DS-3, DS3i-N-12, and DS3XM).
2.
A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards—As needed, complete this procedure to change line and threshold settings for all optical cards.
3.
A118 Modify Alarm Interface Controller–International Settings—As needed, complete this procedure to change external alarms and controls and/or orderwire settings.
4.
A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection—As needed, complete this procedure to change the protection type on DS-1 or DS-3 cards.
5.
A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards—As needed, complete this procedure to change FC_MR-4 card port and threshold settings.
6.
A321 Change Card or PPM Service State—As needed, complete this procedure to change the service state on a card or pluggable port module (PPM).
7.
A322 Manage Pluggable Port Modules—As needed, complete this procedure to provision a multirate PPM, assign the optical line rate, change the optical line rate, and delete PPMs.
8.
A346 Provision the Soak Timer for an ML-Series Card—As needed, complete this procedure to provision the soak timer for an ML-Series card.
9.
A352 View PPM Information on the LCD—As needed, complete this procedure to view wavelength and rate for a PPM on a multirate optical card.
10.
A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards—As needed, complete this procedure to provision the node’s cross-connect mode if mixed mode grooming is required.
NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
This procedure changes the line and threshold settings for electrical cards. |
|
Step 1
Complete the A60 Log into CTC at the node where you want to change the electrical card settings. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the A108 Back Up the Database.
Step 3
Perform any of the following tasks as needed:
- A165 Change Line and Threshold Settings for a DS1-14 or DS1N-14 Card
- A166 Change Line and Threshold Settings for a DS3-12 or DS3N-12 Card
- A167 Change Line and Threshold Settings for a DS3E-12 or DS3N-12E Card
- A168 Change Line and Threshold Settings for the DS3XM-6 Card
- A387 Change Line and Threshold Settings for the DS3XM-12 Card
- A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
- A388 Change Line and Threshold Settings for the DS3/EC1-48 Cards
- A169 Change Line and Threshold Settings for the EC1-12 Card
- A376 Change Line and Threshold Settings for the DS1/E1-56 Cards
Step 4
As needed, complete the A108 Back Up the Database.
Stop. You have completed this procedure.
NTP-A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards
This procedure changes the line and threshold settings for optical (OC-N) cards. |
|
Step 1
Complete the A60 Log into CTC at the node where you want to change the OC-N card settings. If you are already logged in, proceed to Step 2.
Step 2
As needed, complete the A108 Back Up the Database.
Step 3
Perform any of the following tasks as needed:
Step 4
As needed, complete the A108 Back Up the Database.
Stop. You have completed this procedure.
NTP-A118 Modify Alarm Interface Controller–International Settings
This procedure provisions the AIC-I card to receive input from or send output to external devices wired to the backplane (called external alarms and controls or environmental alarms). It also changes orderwire settings. |
|
A258 Provision External Alarms and Controls on the Alarm Interface Controller–International |
|
Step 1
Complete the A60 Log into CTC at the node where you want to change the AIC-I card settings. If you are already logged in, continue with Step 2.
Step 2
As needed, complete the A108 Back Up the Database.
Step 3
Perform any of the following tasks as needed:
Step 4
As needed, complete the A108 Back Up the Database.
Stop. You have completed this procedure.
NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
This procedure converts DS-1 and DS-3 protect cards from 1:1 to 1:N protection. |
|
Step 1
Complete the A60 Log into CTC at the node where you want to convert the DS-1 or DS-3 cards from 1:1 to 1:N protection. If you are already logged in, continue with Step 2.
Step 2
As needed, complete the A108 Back Up the Database.
Step 3
Perform any of the following tasks as needed:
Step 4
As needed, complete the A108 Back Up the Database.
Stop. You have completed this procedure.
NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
This procedure changes the line and threshold settings for storage area network (SAN) cards, including the FC_MR-4. |
|
Step 1
Complete the A60 Log into CTC at the node where you want to change the OC-N card settings. If you are already logged in, continue with Step 2.
Step 2
As needed, complete the A108 Back Up the Database.
Step 3
Perform any of the following tasks as needed:
Step 4
As needed, complete the A108 Back Up the Database.
Stop. You have completed this procedure.
NTP-A321 Change Card or PPM Service State
This procedure changes a card or port’s service state, which is an autonomously generated state that gives the overall condition of the port. |
|
Note
On the OC192-XFP, MRC-12, and MRC-2.5G-4 cards, the PPM is equivalent to an optical port.
Step 1
Complete the A60 Log into CTC at the node where you want to change the card service state.
Step 2
From node view, click the Inventory tab.
Step 3
Choose an Administrative state from the Admin State drop-down list for the card or PPM that you want to change: IS (In-Service) or OOS,MT (Out-of-Service,Maintenance).
Step 5
If an error message appears indicating that the card state cannot be changed from its current state, click OK.
Depending on the Administrative state that you choose, the card or port/PPM transitions to a different service state. For more information about the service states and card state transitions, refer to the “Administrative and Service States” appendix of the Cisco ONS 15454 Reference Manual.
Stop. You have completed this procedure.
NTP-A322 Manage Pluggable Port Modules
This procedure provisions, changes, and deletes PPMs for the MRC-12, MRC-2.5G-4, and OC192-XFP cards. |
|
Step 1
Complete the A60 Log into CTC at the node where you want to provision, change, or delete PPMs. If you are already logged in, continue with Step 2.
Step 2
From the View menu, choose Go to Network View.
a.
Verify that the alarm filter is not turned on. See the A227 Disable Alarm Filtering as necessary.
b.
Verify that no unexplained conditions appear on the network. If unexplained conditions appear, resolve them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide.
c.
Complete the A532 Export CTC Data to export alarm and condition information.
Step 4
As needed, complete the A574 Provision a PPM on the MRC-12 or MRC-2.5G-4 Card. Single-rate PPMs do not require provisioning.
Step 5
As needed, complete the A575 Provision the Optical Line Rate on the MRC-12 or MRC-2.5G-4 Card to assign an OC-3, OC-12, or OC-48 line rate to a multirate PPM.
Step 6
As needed, complete the A576 Change the Optical Line Rate on the MRC-12 or MRC-2.5G-4 Card to change the line rate on a multirate PPM. You cannot change the optical line rate on single-rate PPMs.
Step 7
As needed, complete the A577 Delete a PPM from the MRC-12, MRC-2.5G-4, or OC192-XFP Card.
Stop. You have completed this procedure.
NTP-A346 Provision the Soak Timer for an ML-Series Card
Step 1
Complete the A60 Log into CTC at the node where you want to provision the soak timer for an ML-Series card. If you are already logged in, continue with Step 2.
Step 2
In node view, double-click the ML-Series card that you want to provision.
Step 3
Click the Provisioning tab.
Step 4
Click the Ether Ports or POS Ports subtab and complete the following:
- PSAS—In the appropriate port row, check this check box to enable Pre-Service Alarm Suppression (PSAS), which suppresses all alarms on the port for the time designated in the Soak Time column.
- Soak Time—In the same row, choose the desired soak time (in hours and minutes). Use this column when you have checked PSAS to suppress alarms. When the port detects a signal, the countdown begins for the designated soak time. Soak time hours can be set from 0 to 48. Soak time minutes can be set from 0 to 45 in 15 minute increments.
Stop. You have completed this procedure.
NTP-A352 View PPM Information on the LCD
This procedure displays the line rate and the configured reach for OC-N and MRC cards (MRC-12, MRC-2.5G-4) on the LCD, located on the front of the fan-tray assembly. |
|
Step 1
On the ONS 15454 front panel, repeatedly press the Slot button until the slot number of the card where the PPM resides appears on the LCD.
Step 2
Repeatedly press the Port button. When you see “Status - Lambda” display on the LCD, press the Status button to select that option.
Step 3
Press Status to toggle between “Lambda” and “Line Rate and Reach.”
Step 4
Press Status to select one of those options.
Step 5
Press the Port button as needed to display the information about the desired port.
Stop. You have completed this procedure.s
NTP-A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards
This procedure is used to set or verify cross-connect mode provisioning required for mixed grooming mode. |
|
Step 1
Complete the A60 Log into CTC at the node where you want to change the XC-VXC-10G card settings. If you are already logged in, continue with Step 2.
Step 2
Navigate to the node view in CTC.
Step 3
Click Provisioning > Cross-Connect. The Cross-Connect dialog box is displayed.
Step 4
If necessary, click the Mixed Mode radio button in the Cross-Connect dialog box and click Apply.
Stop. You have completed this procedure.