Cisco Nexus 7710 Switch Site Preparation and Hardware Installation Guide
Switch Specifications
Downloads: This chapterpdf (PDF - 1.57MB) The complete bookPDF (PDF - 5.65MB) | The complete bookePub (ePub - 2.1MB) | Feedback

Contents

Switch Specifications

This appendix includes the following topics:

Environmental Specifications

Environment

Specification

Temperature

Ambient operating

32 to 104°F (0 to 40°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Relative humidity

Ambient (noncondensing) operating

8 to 80%

Ambient (noncondensing) nonoperating

5 to 90%

Altitude

Operating

–500 to 13,123 feet (–152 to 4,000 meters), agency certified 0 to 6500 feet (0 to 1980 meters)

Storage

–1,000 to 30,000 feet (–305 to 9,144 meters)

Switch Dimensions

Switch Component

Width

Depth

Height

Cisco Nexus 7710 chassis

17.3 inches (43.9 cm)

34.0 inches (86.4 cm)

24.35 inches (61.9 cm) (14 RU)

Cable management system and front door

18.3 inches (46.5 cm)

6.5 inches (16.5 cm)

1

1 The total height of the cable management system is within the height of the chassis. The cable management system is added to the front of the chassis but does not add any height to the chassis.

Power Requirements

Component Quantity Maximum Power Typical Power

Supervisor Modules

1 or 2

 

Supervisor 2 Enhanced (N77-SUP2E)

265 W

137 W

F2 I/O Modules

1 to 8

 

48-port 1- and 10-Gigabit Ethernet I/O module (N77-F248XP-23E)

500 W

450 W

F3 I/O Modules

 

48-port 1- and 10-Gigabit Ethernet I/O module (N77-F348XP-23)

480

450

 

24-port 40-Gigabit Ethernet I/O module (N77-F324FQ-25)

740

650

 

12-port 100-Gigabit Ethernet I/O module (N77-F312CK-26)

730

640

Fabric Modules (N77-C7710-FAB-2)

3 to 6

150 W

122 W

Fan Tray (N77-C7710-FAN)

3

600 W

30 W

Maximum Power Available for 3-kW AC Power Supplies

The maximum power available for operations depends on the input power from your power source, the number and output capabilities of your power supplies, and the power redundancy mode that you use. The following table lists the amount of power available for 3-kW power supplies depending on power inputs, numbers of power supplies, and the mode used.

Power Inputs

Power Supplies

Combined Mode

Power Supply Redundancy Mode

Input Source Redundancy Mode

Full Redundancy Mode

1 input (220 V)

1

3000 W

2

6000 W

3000 W

3000 W

3000 W

3

9000 W

6000 W

3000 W

3000 W

4

12000 W

9000 W

6000 W

6000 W

5

15000 W

12000 W

6000 W

6000 W

6

18000 W

15000 W

9000 W

9000 W

7

21000 W

18000 W

9000 W

9000 W

8

24000 W

21000 W

12000 W

12000 W

1 input (110 V)

1

1450 W

2

2900 W

1450 W

1450 W

1450 W

3

4350 W

2900 W

1450 W

1450 W

4

5800 W

4350 W

2900 W

2900 W

5

7250 W

5800 W

2900 W

2900 W

6

8700 W

7250 W

4350 W

4350 W

7

10150 W

8700 W

4350 W

4350 W

8

11600 W

10150 W

5800 W

5800 W

Maximum Power Available for 3-kW DC Power Supplies

The maximum power available for operations depends on the input power from your power source, the number and output capabilities of your power supplies, and the power redundancy mode that you use. The following table lists the amount of power available for 3-kW DC power supplies depending on power inputs, numbers of power supplies, and the mode used.

Power Inputs

Power Supplies

Combined Mode

Power Supply Redundancy Mode

Input Source Redundancy Mode

Full Redundancy Mode

1 input

1

3000 W

2

6000 W

3000 W

3000 W

3000 W

3

9000 W

6000 W

3000 W

3000 W

4

12000 W

9000 W

6000 W

6000 W

5

15000 W

12000 W

6000 W

6000 W

6

18000 W

15000 W

9000 W

9000 W

7

21000 W

18000 W

9000 W

9000 W

8

24000 W

21000 W

12000 W

12000 W

Weights and Quantities for the Chassis, Modules, Fan Trays, and Power Supplies

Component

Weight per Unit

Quantity

Cisco Nexus 7710 Chassis (N77-C7710)

160.0 lb (72.6 kg)

1

Supervisor module (N77-SUP2E)

8.5 lb (3.9 kg)

1 or 2

F2 Series I/O Modules

1 to 8

 

48-port 1- and 10-Gigabit Ethernet I/O module (N77-F248XP-23E)

17.0 lb (7.7 kg)

F3 Series I/O Modules

 

48-port 1- and 10-Gigabit Ethernet I/O module (N77-F348XP-23)

17.0 lb (7.7 kg)

 

24-port 40-Gigabit Ethernet I/O module (N77-F324FQ-25)

17.0 lb (7.7 kg)

 

12-port 100-Gigabit Ethernet I/O module (N77-F312CK-26)

18.5 lb (8.4 kg)

Fabric Modules

3 to 6

 

Fabric-1 module (N77-C7710-FAB-2)

11.0 lb (5.0 kg)

Fan Trays (N7K-C7710-FAN)

8.5 lb (3.9 kg)

3

Power Supplies

1 to 8

 

3-kW AC power supply (N77-AC-3KW)

5.0 lb (2.3 kg)

3-kW DC power supply (N77-DC-3.0KW)

11.0 lb (5.0 kg)

Optional Components

 

Front door (N77-C7710-FDK)

0 or 1

Transceivers, Connectors, and Cables Used with Each I/O Module

Table 1 F2-Series 48-Port 1- and 10-Gigabit Ethernet with XL (N77-F248XP-23E) Transceivers and Cables
Port Type Transceiver or Connector Cable Type

SFP+

DWDM-SFP10G-xx.xx

FET-10G2

SFP-10G-ER

SFP-10G-LR

SFP-10G-LRM

SFP-10G-SR

SFP-10G-ZR3

Fiber optic

SFP-10G-AOC1M

SFP-10G-AOC3M

SFP-10G-AOC5M

SFP-10G-AOC7M

SFP-10G-AOC10M

Active optical cable assembly

SFP-H10GB-CU1M

SFP-H10GB-CU3M

SFP-H10GB-CU5M

Twinax cable, active assembly

SFP

CWDM-SFP-xxxx

DWDM-SFP-xxxx

GLC-BX-D

GLC-BX-U

GLC-EX-SMD

GLC-LH-SMD

GLC-SX-MMD

GLC-T

GLC-ZX-SM

SFP-GE-T

Fiber Optic

2 FETs are used only when connecting this I/O module to a Fabric Extender (FEX).
3 Requires Version 2 or later version.
Table 2 F3 Series 48-port, 1- and 10-Gigabit Ethernet (N7K-F348XP-23) Transceivers and Cables
Port Type Transceiver or Connector Cable Type

SFP+

SFP-10G-SR

SFP-10G-LRM

FET-10G

Multi-mode fiber (MMF)

DWDM-SFP10G-xx.xx

SFP-10G-ER

SFP-10G-LR

SFP-10G-LRM

SFP-10G-ZR

Single-mode fiber (SMF)

SFP-H10GB-CU1M

SFP-H10GB-CU3M

SFP-H10GB-CU5M

Twinax cable assembly, passive

SFP-H10GB-ACU7M

SFP-H10GB-ACU10M

Twinax cable assembly, active

SFP-10G-AOC1M

SFP-10G-AOC2M

SFP-10G-AOC3M

SFP-10G-AOC5M

SFP-10G-AOC7M

SFP-10G-AOC10M

Optical cable assembly, active

Table 3 F3 Series 24-port, 40-Gigabit Ethernet (N7K-F324FQ-25) Transceivers and Cables
Port Type Transceiver or Connector Cable Type

QSFP+

QSFP-40G-SR4

QSFP-40G-CSR4

QSFP-40G-SR-BD

Multi-mode fiber (MMF)

QSFP-40G-LR4

Single-mode fiber (SMF)

QSFP-H40G-CU1M

QSFP-H40G-CU3M

QSFP-H40G-CU5M

Direct attach copper, passive

QSFP-H40G-ACU7M

QSFP-H40G-ACU10M

Direct attach copper, active

QSFP-4SFP10G-CU1M

QSFP-4SFP10G-CU3M

QSFP-4SFP10G-CU5M

Direct attach breakout copper, passive

QSFP-4SFP10G-ACU7M

QSFP-4SFP10G-ACU10M

Direct attach breakout copper, active

QSFP-H40G-AOC1M

QSFP-H40G-AOC2M

QSFP-H40G-AOC3M

QSFP-H40G-AOC5M

QSFP-H40G-AOC7M

QSFP-H40G-AOC10M

Active optical cable assembly

Table 4 F3 Series 12-port, 100-Gigabit Ethernet (N7K-F312CK-26) Transceivers and Cables
Port Type Transceiver or Connector Cable Type

CPAK

CPAK-100G-SR10

Multi-mode fiber (MMF)

CPAK-100G-LR4

Single-mode fiber (SMF)

100-Gb CPAK Transceiver Specifications

The 100-Gigabit CPAK transceivers are used with the F3-Series 100-Gigabit I/O module (N77-F312CK-26).

For the cable specifications that apply to these transceivers, see the following table.

Transceiver Cable Type Connector Type Wavelength (nm) Core Size (microns) Modal Bandwidth (MHz-km) Maximum Cable Distance

CPAK-100G-LR4

SMF

LC Duplex

1310

G.652

6.21 miles (10 km)

CPAK-100G-SR10

MMF

24-fiber MPO/MTP

850

50.0

50.0

2000 (OM3)

4700 (OM4)

328 feet (100 m)

492 feet (150 m)

For the environmental specifications, see the following table.

Parameter Specification

Storage temperature

–40 to 158°F (–40 to 70°C)

Operating temperature

32 to 104°F (0 to 40°C)

Storage relative humidity

5 to 95 percent, noncondensing

Operating relative humidity

5 to 90 percent, noncondensing

40-Gb QSFP+ Transceiver Specifications

The 40-Gigabit QSFP+ transceivers are used with the M2- and F3-Series 40-Gigabit I/O modules (N7K-M206FQ-23L, N7K-F312CK-26, and N77-F324FQ-25).

The following figure identifies the major features of these transceivers.

1

Optical bore

2

Pull tab

For the cable specifications that apply to these transceivers, see the following table.

Transceiver Cable Type Connector Type Wavelength (nm) Core Size (microns) Modal Bandwidth (MHz-km) Maximum Cable Distance

QSFP-10G-CSR4

MMF

12-fiber MTP/MPO

850

62.5

50.0

50.0

50.0

200

500

2000

4700

108 feet (33 m)

269 feet (82 m)

984 feet (300 m)

1312 feet (400 m)

QSFP-10G-LR4

SMF

LC Duplex

1310

G.652

61 miles (10 km)

QSFP-10G-SR4

MMF

PC or UPC

850

50.0

50.0

50.0

500 (OM2)

2000 (OM3)

4700 (OM4)

98 feet (30 m)

328 feet (100 m)

492 feet (150 m)

QSFP-40G-SR-BD

MMF

LC Duplex

850/900

50.0

50.0

50.0

500 (OM2)

2000 (OM3)

4700 (OM4)

98 feet (30 m)

328 feet (100 m)

328 feet (100 m)

QSFP-H40G-CUxM

Direct attach copper, passive

QSFP+ to QSFP+

3.3 feet (1 m)

9.8 feet (3 m)

16.4 feet (5 m)

QSFP-H40G-ACUxM

Direct attach copper, active

QSFP+ to QSFP+

23 feet (7 m)

33 feet (10 m)

QSFP-4SFP10G-CUxM

Direct attach breakout copper, passive

QSFP+ to QSFP+

3.3 feet (1 m)

9.8 feet (3 m)

16.4 feet (5 m)

QSFP-4X10G-ACUxM

Direct attach breakout copper, active

QSFP+ to QSFP+

23 feet (7 m)

33 feet (10 m)

QSFP-H40G-AOCxM

Active optical cable assembly

QSFP+ to QSFP+

3.3 feet (1 m)

6.6 feet (2 m)

9.8 feet (3 m)

16.4 feet (5 m)

23 feet (7 m)

33 feet (10 m)

For the optical specifications, see the following table.

Transceiver Transceiver Type Transmit Power (dBm) Receive Power (dBm) Transmit and Receive Wavelength (nm)

QSFP-10G-SR4

MPO/MTP multifiber

-1.0 (maximum per lane)

-7.6 (minimum per lane)

2.4 (maximum per lane)

-9.5 (minimum per lane)

840 to 860 nm

For the environmental specifications, see the following table.

Parameter Specification

Storage temperature

–40 to 185°F (–40 to 85°C)

Operating temperature

32 to 104°F (0 to 40°C)

Case temperature

–40 to 158°F (–40 to 70°C)

Storage relative humidity

5 to 95 percent

10-Gb SFP+ Optical Transceivers and Fabric Extender Transceivers

The 10-Gigabit SFP+ transceivers are used with the following I/O modules:

  • F2 Series Enhanced 48-port 1- and 10-Gigabit Ethernet I/O module (N77-F248XP-23E)
  • F3 Series 48-port, 1- and 10-Gigabit Ethernet I/O module (N77-F348XP-23)

You can use the SFP-10G-SR, SFP-10G-LR, and the 10-Gigabit Fabric Extender Transceiver (FET) to connect the following I/O modules to Fabric Extenders (FEXs):

  • F2 Series Enhanced 48-port 1- and 10-Gigabit I/O module (N77-F248XP-23E)
  • F3 Series 48-port, 1- and 10-Gigabit Ethernet I/O module (N77-F348XP-23)

On the other end of the connections using the SFP-10G-SR, SFP-10G-LR, and FET transceivers, you can connect to the following FEXs:

  • Cisco Nexus 2248TP FEX
  • Cisco Nexus 2248TP-E FEX
  • Cisco Nexus 2248PQ-E FEX
  • Cisco Nexus 2232TM-E FEX
  • Cisco Nexus 2232TM FEX
  • Cisco Nexus 2232PP FEX

The following figure identifies the major features of these transceivers.

1

Receive optical bore

4

Clasp shown in open position

2

Transmit optical bore

5

Dust plug

3

Clasp shown in closed position

   

For the cable specifications that apply to these transceivers, see the following table.

Transceiver Cable Type Connector Type Wavelength (nm) Core Size (microns) Modal Bandwidth (MHz-km) Maximum Cable Distance

FET-10G

MMF

Dual LC/PC

850

50.0

50.0

500

2000

82 feet (25 m)

328 feet (100 m)

SFP-10G-ER

SMF

Dual LC/PC

1550

G.652 fiber

24.9 miles (40 km)

SFP-10G-LR

SMF

Dual LC/PC

1310

G.652 fiber

6.2 miles (10 km)

SFP-10G-LRM

MMF

Dual LC/PC

1310

62.5

50

50

500

400

500

722 feet (220 m)

328 feet (100 m)

722 feet (220 m)

SMF

G.652

984 feet (300 m)

SFP-10G-SR

MMF

Dual LC/PC

850

62.5

62.5

50

50

50

160

200

400

500

2000

85 feet (26 m)

108 feet (33 m)

216 feet (66 m)

269 feet (82 m)

984 feet (300 m)

SFP-10G-ZR

SMF

 

1550

G.652

49.7 miles (80 km)

SFP-H10GB-CU1M

Twinax cable, passive, 30-AWG cable assembly

3.3 feet (1 m)

SFP-H10GB-CU3M

Twinax cable, passive, 30-AWG cable assembly

9.8 feet (3 m)

SFP-H10GB-CU5M

Twinax cable, passive, 30-AWG cable assembly

16.4 feet (5 m)

SFP-H10GB-ACU7M

Twinax cable, active, 30-AWG cable assembly

22.8 feet (7 m)

SFP-H10GB-ACU10M

Twinax cable, active, 30-AWG cable assembly

32.5 feet (10 m)

For the optical specifications, see the following table.

Transceiver Transceiver Type Transmit Power (dBm) Receive Power (dBm) Transmit and Receive Wavelength (nm)

SFP-10G-ER

10GBASE-ER, 1550-nm SMF

4.0 (maximum per lane)

-4.7 (minimum per lane)

–1.0 (maximum per lane)

–15.8 (minimum per lane)

1530 to 1565 nm

SFP-10G-LR

10GBASE-LR, 1310-nm SMF

0.5 (maximum per lane)

-8.2 (minimum per lane)

0.5 (maximum per lane)

-14.4 (minimum per lane)

1260 to 1355 nm

SFP-10G-LRM

10GBASE-LRM, 1310-nm MMF and SMF

0.5 (maximum per lane)

-6.5 (minimum per lane)

0.5 (maximum per lane)

-8.4 (minimum per lane) (in average)

-6.4 (minimum per lane) (in OMA)4

1260 to 1355 nm

SFP-10G-SR

10GBASE-SR, 850-nm MMF

–1.2 (maximum per lane)5

–7.3 (minimum per lane)

0.5 (maximum per lane)

-8.2 (minimum per lane)

840 to 860 nm

4 Both the average and the OMA specifications must be met simultaneously.
5 The launch power shall be the lesser of the class 1 safety limit or the maximum receive power. Class 1 laser requirements are defined by IEC 60825-1:2001.

For the environmental specifications, see the following table.

Parameter Specification

Storage temperature

–40 to 185°F (–40 to 85°C)

Operating temperature

32 to 158°F (0 to 70°C)

Case temperature

–40 to 158°F (–40 to 70°C)

Module supply voltage

3.1 to 3.5 V

10BASE-DWDM SFP+ Transceiver Specifications

The Dense Wavelength Division Multiplexing (DWDM) SFP+ transceivers are part of a DWDM optical network to provide high-capacity bandwidth across a fiber-optic network. There are 32 fixed-wavelength DWDM SFP+ transceivers that support the International Telecommunications Union (ITU) 100-GHz wavelength grid. These transceivers have duplex SC connectors. DWDM SFP+ transceivers can transmit and receive optical signals up to 50 miles (80 km) depending on the quality of the fiber-optic cable used.

DWDM SFP+ transceivers look like the typical 10GBASE-X SFP+ transceivers as shown in the following figure.

1

Receive optical bore

4

Clasp shown in open position

2

Transmit optical bore

5

Dust plug

3

Clasp shown in closed position

   

For the specifications that differentiate the 10GBASE-DWDM SFP+ transceivers, see the 10-Gigabit Ethernet Transceiver Modules Compatibility Matrix.

1-Gb SFP Transceiver Specifications

The 1-Gigabit Ethernet SFP transceivers are used with the following 1-Gigabit Ethernet I/O modules:

  • F2 Series 48-port 1- and 10-Gigabit Ethernet I/O modules (N7K-F248XP-23E)

1000BASE-CWDM SFP Transceiver Cables

The Coarse Wavelength Division Multiplexing (CWDM) SFP transceivers are hot-swappable transceivers that you plug into SFP-compatible I/O modules. The CWDM SFP transceiver uses an LC optical connector to connect to a single-mode fiber-optic (SMF) cable. You can connect the CWDM SFPs to CWDM passive optical system optical add/drop multiplexer (OADM) modules or multiplexer/demultiplexer plug-in modules using SMF cables. CWDM SFP transceivers can transmit and receive optical signals up to 61 miles (100 km) depending on the quality of the fiber-optic cable used.

CWDM SFP transceivers are color coded to indicate their designated optical wavelength. The following figure shows the CWDM transceiver, which looks like a standard 1000BASE-X SFP transceiver with a colored arrow and bail clasp to indicate the designated wavelength.

Figure 1. CWDM SFP Transceiver (Yellow Color Code)



1

Colored arrow on label specifies the wavelength

4

Bail clasp

2

Receive optical bore

5

Dust plug

3

Transmit optical bore

   

Whenever the transceiver receive optical bores are not filled with optical cables, you should minimize the chance of contamination by plugging the transceiver with its dust plug.

For the specifications that differentiate the 1000BASE-CWDM SFP transceivers, see the Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix. For specifications and installation information that apply to all CWDM SFP transceivers, see the Cisco SFP and SFP+ Transceiver Module Installation Notes.

1000BASE-DWDM SFP Transceiver Specifications

The Dense Wavelength Division Multiplexing (DWDM) SFP transceivers are part of a DWDM optical network to provide high-capacity bandwidth across a fiber-optic network. There are 40 fixed-wavelength DWDM SFP transceivers that support the International Telecommunications Union (ITU) 100-GHz wavelength grid. These transceivers have duplex SC connectors. DWDM SFP transceivers can transmit and receive optical signals up to 50 miles (80 km) depending on the quality of the fiber-optic cable used.

DWDM SFP transceivers look like the typical 1000BASE-X transceivers as shown in the following figure.

Figure 2. 1000BASE-DWDM SFP Transceiver



1

Receive optical bore

3

Bail clasp

2

Transmit optical bore

4

Dust plug

For the specifications that differentiate the 1000BASE-DWDM SFP transceivers, see the Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix. For specifications and installation information that apply to all CWDM SFP transceivers, see the Cisco SFP and SFP+ Transceiver Module Installation Notes.

1000BASE-X SFP Transceiver Specifications

The 1000BASE-X SFPs are hot-swappable transceivers that you plug into SFP-compatible I/O modules.

The 1000BASE-X transceiver, shown in the following figure, provides an optical connection for fiber-optic cables.

Figure 3. 1000BASE-X SFP Transceiver



1

Receive optical bore

3

Bail clasp

2

Transmit optical bore

4

Dust plug

For the 1000BASE-X transceiver cable specifications, see the following table.

Transceiver Type Cable Type Connector Type Wavelength (nm) Core Size (microns) Modal Bandwidth (MHz-km) Maximum Cable Distance

1000BASE-BX10 (GLC-BX-U)

SMF6

Single LC/PC

1310

G.6527

6.2 miles (10 km)

1000BASE-BX10 (GLC-BX-D)

SMF1

Single LC/PC

1490

G.6522

6.2 miles (10 km)

1000BASE-SX (GLC-SX-MMD, GLC-SX-MM, and SFP-GE-S)

MMF8

LC duplex

850

62.5

62.5

50.0

50.0

160

200

400

500

722 feet (220 m)

902 feet (275 m)

1640 feet (500 m)

1804 feet (550 m)

1000BASE-LX (GLC-LH-SMD, GLC-LH-SM, and SFP-GE-L)

MMF3

LC duplex

1310

62.5

50.0

50.0

500

400

500

1804 feet (550 m)9

1804 feet (550 m)4

1804 feet (550 m)4

SMF1

LC duplex

1310

G.6522

6.2 miles (10 km)

1000BASE-ZX (GLC-ZX-SM and SFP-GE-Z)

SMF1

LC duplex

1550

G.6522

Approximately 43.4 to 60 miles (70 to 100 km) depending on link loss

6 Single-mode fiber optic (SMF)
7 ITU-T G652 SMF as specified by the IEEE 802.32 standard.
8 Multimode fiber optic (MMF)
9 You must use a mode-conditioning patch cord, as specified by the IEEE standard, regardless of the amount of span.

The transceivers that support Digital Optical Monitoring have a greater range of temperatures for operations, as shown in the following table.

Transceiver Type Part Number Digital Optical Monitoring Support Operating Temperature Storage Temperature

1000BASE-SX

GLC-SX-MMD

Yes

EXT10

–40 to 185°F (–40 to 85°C)

GLC-SX-MM

No

COM11

SFP-GE-S

Yes

EXT5

1000BASE-LX

GLC-LH-SMD

Yes

EXT5

GLC-LH-SM

No

COM6

SFP-GE-Z

Yes

EXT5

1000BASE-ZX

GLC-ZX-SM

No

COM6

SFP-GE-Z

Yes

EXT5

10 Extended (EXT) temperature range is 23 to 185°F (-5 to 85°C)
11 Commercial (COM) temperature range is 32 to 158°F (0 to 70°C)

RJ-45 Module Connectors

The RJ-45 connector connects Category 3, Category 5, Category 5e, Category 6, or Category 6A foil twisted-pair or unshielded twisted-pair cable from the external network to the following module interface connectors:

  • Supervisor modules
    • CONSOLE port
    • COM1/AUX port
    • MGMT ETH port
  • Fabric Extenders (Cisco Nexus 2232PP, 2232TM, 2232TM-E, 2248PQ, 2248TP, and 2248TP-E FEXs)
    • 100/1000 downlink ports

Caution


To comply with GR-1089 intrabuilding, lightning immunity requirements, you must use a foil twisted-pair (FTP) cable that is properly grounded at both ends.


The following figure shows the RJ-45 connector.

Figure 4. RJ-45 Connector



1

Pin 1

2

Pin 2

Power Supply Cable Specifications

3-kW AC Power Cord Specifications

Locale Power Cord Part Number Cord Set Rating Power Cord Illustration

Australia and New Zealand

CAB-AC-16A-AUS

16A, 250 VAC

Peoples Republic of China

CAB-AC-16A-CH

16A, 250 VAC

Continental Europe

CAB-AC-2500W-EU

16A, 250 VAC

International

CAB-AC-2500W-INT

16A, 250 VAC

Israel

CAB-AC-2500W-ISRL

16A, 250 VAC

Japan and North America (non locking) 200-240 VAC operation

CAB-AC-2500W-US1

16A, 250 VAC

Japan and North America (locking) 200-240 VAC operation

CAB-AC-C6K-TWLK

16A, 250 VAC

Japan and North America 100-120 VAC operation

CAB-7513AC

16A, 250 VAC

Power distribution unit (PDU)

CAB-C19-CBN

16A, 250 VAC

Switzerland

CAB-ACS-16

16A, 250 VAC

3-kW DC Power Cord Specifications

Locale Part Number Cord Ratings Power Cord Comments

All

12

45 A

6 AWG

12 Power cords used for the 3-kW DC power supply are supplied by the customer.