Guest

Cisco Catalyst 6000 Series Switches

Field Notice: Some MultiChannel T1/E1 Port Adapters on FlexWAN Line Cards May Not Be Recognized


Updated January 2, 2002

September 1, 2000


Products Affected

Product

Top Assembly

Printed Circuit Assembly

Comments

Part Number

Rev.

Part Number

Rev.

PA-MC-8T1

800-02984-02

-C0

73-2488-06

-A0

^ASY,ELMECH,PA-POTENT,T1

WS-X6182-2PA

68-0775-04

-A0

73-3869-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-04

-A0

73-3921-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

PA-MC-4T1

800-02986-02

-B0

73-2691-06

-A0

^ASY,ELMECH,PA-POTENT,4T1

PA-MC-2T1

800-04989-01

-B0

73-3927-01

-B0

^ASY,ELMECH,PA-POTENT-2PORT,T1

WS-X6182-2PA

68-0775-04

-A1

73-3869-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

PA-MC-2E1/120

800-05008-01

-D0

73-3926-01

-B0

^ASY,ELMECH,PA-POTENT-2PORT,E1

PA-MC-8DSX1

800-02987-02

-B0

73-2690-06

-A0

^ASY,ELMECH,PA-POTENT,DSX1

PA-MC-8E1/120

800-02985-02

-B0

73-2543-06

-A0

^ASY,ELMECH,PA-POTENT,E1

WS-X6182-2PA

68-0775-04

-A1

73-3921-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-05

-A0

73-3869-05

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-05

-A0

73-3921-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-06

-A0

73-3869-06

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-06

-A0

73-3921-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-07

-A0

73-3869-07

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-07

-A0

73-3869-07

-B0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-07

-A0

73-3921-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-07

-B0

73-3869-07

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-07

-B0

73-3869-07

-B0

^FNLASY,PCA,FLEX WAN MODULE,C6000

WS-X6182-2PA

68-0775-07

-B0

73-3921-04

-A0

^FNLASY,PCA,FLEX WAN MODULE,C6000

Problem Description

FlexWAN line cards with hardware version 1.2 or earlier are affected.

Some MultiChannel port adapters installed on FlexWAN line cards may not power up or be recognized by the system. The port adapters that do not work with the FlexWAN line card are PA-MC-XXX.

To check the hardware version, enter the following commands from the enable prompt:

      console prompt> (enable) show module
      Mod Slot Ports Module-Type               Model               Status
      --- ---- ----- ------------------------- ------------------- --------
      1   1    2     1000BaseX Supervisor      WS-X6K-SUP1A-2GE    ok
      15  1    1     Multilayer Switch Feature WS-F6K-MSFC         ok
      2   2    2     1000BaseX Supervisor      WS-X6K-SUP1A-2GE    standby
      16  2    1     Multilayer Switch Feature WS-F6K-MSFC         ok
      3   3    48    10/100BaseTX Ethernet     WS-X6248-RJ-45      ok
      4   4    8     1000BaseX Ethernet        WS-X6408-GBIC       ok
      5   5    0     FlexWAN Module            WS-X6182-2PA        ok
      7   7    16    1000BaseX Ethernet        WS-X6416-GBIC       ok
     

      Mod Module-Name         Serial-Num
      --- ------------------- -----------
      1                       SAD04010599
      15                      SAD040104ZH
      2                       SAD03423465
      16                      SAD035101AB
      3                       SAD040305C7
      4                       SAD03464719
      5                       SAD041406XB
      7                       SAD03427612
      

      Mod MAC-Address(es)                        Hw     Fw         Sw
      --- -------------------------------------- ------ ---------- -----------------
      1   00-d0-d3-28-f4-f6 to 00-d0-d3-28-f4-f7 3.1    5.3(1)     5.4(2)
          00-d0-d3-28-f4-f4 to 00-d0-d3-28-f4-f5
          00-d0-00-9d-90-00 to 00-d0-00-9d-93-ff
      15  00-d0-d3-28-f4-f8 to 00-d0-d3-28-f5-37 1.3    12.1(1)E,  12.1(1)E,
      2   00-d0-bc-f2-b6-ce to 00-d0-bc-f2-b6-cf 1.0    5.2(1)     5.4(2)
          00-d0-bc-f2-b6-cc to 00-d0-bc-f2-b6-cd
      16  00-30-96-b0-59-c0 to 00-30-96-b0-59-ff 1.2    12.1(1)E,  12.1(1)E,
      3   00-30-19-c2-ee-80 to 00-30-19-c2-ee-af 1.1    4.2(0.24)V 5.4(2)
      4   00-30-96-2b-a1-84 to 00-30-96-2b-a1-8b 2.3    4.2(0.24)V 5.4(2)
      5   00-b0-c2-f2-79-40 to 00-b0-c2-f2-79-7f 1.1    12.1(1)E,  12.1(1)E,
      7   00-d0-97-38-58-38 to 00-d0-97-38-58-47 0.102  5.3(1)     5.4(2)
   

Background

Some MultiChannel port adapters installed on FlexWAN line cards have been reported as not powering on or not being recognized by the Cisco Catalyst system in which they are installed. Only the combination of a FlexWAN line card and specific MultiChannel port adapters exhibit this problem.

Problem Symptoms

When the MultiChannel port adapter installed on a FlexWAN line card is powered on, the port adapter enable LED does not illuminate and the following console message is displayed: Port Adapter card type 65535 is not recognized.

Re-seating the FlexWAN line card does not clear the problem.

Workaround/Solution

Affected units should be replaced using the normal return materials authorization (RMA) process.

For More Information