Cisco CRS-1 Carrier Routing System 8-Slot Line Card Chassis Installation Guide
Cisco CRS-1 8-Slot Line Card Chassis Specifications

Table Of Contents

CRS-1 8-Slot Line Card Chassis Specifications


CRS-1 8-Slot Line Card Chassis Specifications


The following table lists the specifications for the Cisco CRS-1 Carrier Routing System 8-Slot Line Card Chassis.

Table A-1 Cisco CRS-1 8-Slot Line Card Chassis Component and Power Specifications 

Supported Cards and Modules

8 modular services cards (MSCs

8 physical layer interface modules (PLIMs),
one for each MSC

4 switch fabric cards (SFCs)

2 route processors (RPs)

2 fan trays

1 air filter

Power Distribution Units

2 AC or 2 DC power distribution units (PDUs)
(cannot mix AC and DC PDUs in the chassis)

DC PDU

Supports 1 DC power entry module (PEM)

AC PDU

Supports 1 AC rectifier module

Maximum Power Consumption

This represents total input power.

Maximum DC

8.0 kW

Maximum AC

8.75 kW (Delta or Wye 3-phase)

 

Note Proper grounding is also required at the site to ensure that equipment is not damaged by lightning or power surges.

DC Power Lug Torque Ranges
 

Minimum torque

20 in-lb (2.2 N-m)

Maximum torque

30 in-lb (3.3 N-m)

Power Redundancy
 

DC

2N (three "A" battery plant feeds for one PDU, and three "B" battery plant feeds for the other PDU)

AC (Delta or Wye 3-phase)

2N (two independent Delta or Wye 3-phase power sources required)

DC Input
 

Nominal input voltage

-48 VDC North America
-54 VDC Telco (RBOC)
-60 VDC International
(range -40.5 to -75 VDC)

Input current
(PDU rated for 60 A)

56 A (nominal)
66 A at -40.5 VDC (maximum)

AC Input, Delta 3-phase

3W + PE

Input voltage

3-phase 200 to 240 VAC (nominal)
(range 170 to 264 VAC, phase-to-phase)

Line frequency

50 to 60 Hz
(range 47 to 63 Hz)

Recommended AC service
(PDU rated for 24 A)

30 A

AC Input, Wye 3-phase

3W + N + PE

Input voltage

3-phase 200 to 240 VAC (nominal)
(range 170 to 264 VAC, phase-to-neutral)
(range 295 to 457 VAC, phase-to-phase)

Line frequency

50 to 60 Hz (nominal)
(range 47 to 63 Hz)

Recommended AC service
(PDU rated for 14 A)

16 A International
20 A North America


The following table lists the environmental specifications for the Cisco CRS-1 8-slot line card chassis.

Table A-2 Cisco CRS-1 8-Slot Routing System Environmental Specifications 

Description
Value

Temperature

Operating, nominal: 41° to 104°F (5° to 40°C)
Operating, short-term: 23° to 122°F (-5° to 50°C)
Nonoperating: -40° to 158°F (-40° to 70°C)

Humidity

Operating: 5 to 85% noncondensing
Nonoperating: 5 to 90% noncondensing, short-term operation

Altitude

1 to 5,906 ft (-60 to 1,800 m) at 122°F (50°C), short-term
Up to 13,123 ft (4,000 m) at 104°F (40°C) or below

Heat dissipation

27,350 BTUs/hr

External cooling requirements

2.3 tons

Acoustic noise

74 dB at 3.28 ft. (1 meter) in front of chassis
(nominal reading at room temperature)

Shock

Operating: 5 to 500 Hz, 0.5g1 (0.1 oct/min)2
Nonoperating: 5 to 100 Hz, 1 g (0.1 oct/min)
100 to 500 Hz, 15 g (0.2 oct/min)
500 to 1000 Hz, 1.5 g (0.2 oct/min)

Vibration

Operating: 0.35 Grms3 from 3 to 500 Hz
Nonoperating: 1.0 Grms from 3 to 500 Hz

1 g = Gravity

2 oct/min = Octave per minute

3 Grms = The root mean square value of acceleration, where 1G equals 32.17 ft/sec (9.81 m/sec).