Cisco UCS Faults
This chapter provides information about the faults that may be raised in a Cisco UCS instance.
fltFabricComputeSlotEpMisplacedInChassisSlot
Fault Code: F0156
Message
Server, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricComputeSlotEpMisplacedInChassisSlot
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltFabricComputeSlotEpServerIdentificationProblem
Fault Code: F0157
Message
Problem identifying server in slot [chassisId]/[slotId]
Explanation
Recommended Action
Fault Details
Cause: server-identification-problem
mibFaultName: fltFabricComputeSlotEpServerIdentificationProblem
moClass: fabric:ComputeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
fltVnicEtherConfig-failed
Fault Code: F0169
Message
Eth vNIC [name], service profile [name] failed to apply configuration
Explanation
Recommended Action
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicEtherConfigFailed
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltVnicFcConfig-failed
Fault Code: F0170
Message
FC vHBA [name], service profile [name] failed to apply configuration
Explanation
Recommended Action
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicFcConfigFailed
Affected MO: org-[name]/ls-[name]/fc-[name]
Affected MO: org-[name]/san-conn-pol-[name]/fc-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/fc-[name]
fltProcessorUnitInoperable
Fault Code: F0174
Message
Processor [id] on server [chassisId]/[slotId] operability: [operability]Processor [id] on rack server [id] operability: [operability]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltProcessorUnitInoperable
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalNonCritical
Fault Code: F0175
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltProcessorUnitThermalNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalThresholdCritical
Fault Code: F0176
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltProcessorUnitThermalThresholdCritical
Callhome Type: environmental
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitThermalThresholdNonRecoverable
Fault Code: F0177
Message
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltProcessorUnitThermalThresholdNonRecoverable
Callhome Type: environmental
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdNonCritical
Fault Code: F0178
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdCritical
Fault Code: F0179
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltProcessorUnitVoltageThresholdNonRecoverable
Fault Code: F0180
Message
Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltProcessorUnitVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltStorageLocalDiskInoperable
Fault Code: F0181
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageLocalDiskInoperable
moClass: storage:LocalDisk
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageItemCapacityExceeded
Fault Code: F0182
Message
Disk usage for partition [name] on fabric interconnect [id] exceeded 70%
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageItemCapacityExceeded
Affected MO: sys/switch-[id]/stor-part-[name]
fltStorageItemCapacityWarning
Fault Code: F0183
Message
Disk usage for partition [name] on fabric interconnect [id] exceeded 90%
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageItemCapacityWarning
Affected MO: sys/switch-[id]/stor-part-[name]
fltMemoryUnitDegraded
Fault Code: F0184
Message
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltMemoryUnitDegraded
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitInoperable
Fault Code: F0185
Message
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltMemoryUnitInoperable
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdNonCritical
Fault Code: F0186
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdCritical
Fault Code: F0187
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdCritical
Callhome Type: environmental
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryUnitThermalThresholdNonRecoverable
Fault Code: F0188
Message
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryUnitThermalThresholdNonRecoverable
Callhome Type: environmental
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltMemoryArrayVoltageThresholdNonCritical
Fault Code: F0189
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]Memory array [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltMemoryArrayVoltageThresholdCritical
Fault Code: F0190
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]Memory array [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltMemoryArrayVoltageThresholdNonRecoverable
Fault Code: F0191
Message
Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]Memory array [id] on server [chassisId]/[slotId]/[serverInstanceId] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryArrayVoltageThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]
fltAdaptorUnitUnidentifiable-fru
Fault Code: F0200
Message
Adapter [id] in server [id] has unidentified FRUAdapter [id] in server [chassisId]/[slotId] has unidentified FRUAdapter [id] in server [chassisId]/[slotId]/[serverInstanceId] has unidentified FRU
Explanation
Recommended Action
Fault Details
Cause: unidentifiable-fru
mibFaultName: fltAdaptorUnitUnidentifiableFru
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorUnitMissing
Fault Code: F0203
Message
Adapter [id] in server [id] presence: [presence]Adapter [id] in server [chassisId]/[slotId] presence: [presence]Adapter [id] in server [chassisId]/[slotId]/[serverInstanceId] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorUnitMissing
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorUnitAdaptorReachability
Fault Code: F0206
Message
Adapter [id]/[id] is unreachableAdapter [chassisId]/[slotId]/[id] is unreachable
Explanation
Recommended Action
Fault Details
Cause: connectivity-problem
mibFaultName: fltAdaptorUnitAdaptorReachability
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]
fltAdaptorHostIfLink-down
Fault Code: F0207
Message
Adapter [transport] host interface [id]/[id]/[id] link state: [linkState]Adapter [transport] host interface [chassisId]/[slotId]/[id]/[id] link state: [linkState]Adapter [transport] host interface [chassisId]/[slotId]/[serverInstanceId] link state: [linkState]
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorHostIfLinkDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-scsi-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-scsi-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-scsi-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]
fltAdaptorExtIfLink-down
Fault Code: F0209
Message
Adapter uplink interface [id]/[id]/[id] link state: [linkState]. Please verify connectivity to Fabric Interconnect. Acknowledging FEX might be required.Adapter uplink interface [chassisId]/[slotId]/[id]/[id] link state: [linkState]. Please verify connectivity to Fabric Interconnect. Acknowledging chassis might be required.
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorExtIfLinkDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltPortPIoLink-down
Fault Code: F0276
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPortPIoLinkDown
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoFailed
Fault Code: F0277
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPortPIoFailed
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoHardware-failure
Fault Code: F0278
Message
[transport] port [portId] on chassis [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure
Explanation
Recommended Action
Fault Details
mibFaultName: fltPortPIoHardwareFailure
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltPortPIoSfp-not-present
Fault Code: F0279
Message
[transport] port [portId] on chassis [id] oper state: [operState][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPortPIoSfpNotPresent
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltFabricExternalPcDown
Fault Code: F0282
Message
[type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual][type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual]
Explanation
Recommended Action
Fault Details
Cause: operational-state-down
mibFaultName: fltFabricExternalPcDown
moClass: fabric:ExternalPc
Affected MO: fabric/eth-estc/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]
Affected MO: fabric/eth-estc/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/fc-estc/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/fc-estc/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]
Affected MO: fabric/lan/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
Affected MO: fabric/san/[id]/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/pc-[portId]
Affected MO: fabric/san/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/net-[name]/pc-switch-[switchId]-pc-[portId]
fltDcxVcDown
Fault Code: F0283
Message
[transport] VIF [id] on server [chassisId] / [slotId] of switch [switchId] down, reason: [stateQual][transport] VIF [id] on server [id] of switch [switchId] down, reason: [stateQual][transport] VIF [id] on server [chassisId]/[slotId]/[serverInstanceId] of switch [switchId] down, reason: [stateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltDcxVcDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]
fltNetworkElementInoperable
Fault Code: F0291
Message
Fabric Interconnect [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltNetworkElementInoperable
Callhome Type: diagnostic
Affected MO: sys/switch-[id]
fltMgmtEntityDegraded
Fault Code: F0293
Message
Fabric Interconnect [id], HA Cluster interconnect link failure
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtEntityDegraded
Callhome Type: diagnostic
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDown
Fault Code: F0294
Message
Fabric Interconnect [id], HA Cluster interconnect total link failure
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtEntityDown
Callhome Type: diagnostic
Affected MO: sys/mgmt-entity-[id]
fltDcxNsFailed
Fault Code: F0304
Message
Server [chassisId]/[slotId] (service profile: [assignedToDn]) virtual network interface allocation failed.Server [id] (service profile: [assignedToDn]) virtual network interface allocation failed.Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) virtual network interface allocation failed.
Explanation
Recommended Action
Fault Details
Cause: insufficient-resources
mibFaultName: fltDcxNsFailed
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/dcxns-[switchId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/dcxns-[switchId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/dcxns-[switchId]
fltComputePhysicalInsufficientlyEquipped
Fault Code: F0305
Message
Server [id] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has insufficient number of DIMMs and/or CPUs
Explanation
Recommended Action
Fault Details
Cause: insufficiently-equipped
mibFaultName: fltComputePhysicalInsufficientlyEquipped
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalIdentityUnestablishable
Fault Code: F0306
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRUServer [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRUServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has an invalid FRU
Explanation
Recommended Action
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalIdentityUnestablishable
moClass: compute:Physical
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputeBoardPowerError
Fault Code: F0310
Message
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [id] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) power: [operPower]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeBoardPowerError
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputePhysicalPowerProblem
Fault Code: F0311
Message
Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) oper state: [operState]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalPowerProblem
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalThermalProblem
Fault Code: F0312
Message
Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) oper state: [operState]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalThermalProblem
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalBiosPostTimeout
Fault Code: F0313
Message
Server [id] (service profile: [assignedToDn]) BIOS failed power-on self testServer [chassisId]/[slotId] (service profile: [assignedToDn]) BIOS failed power-on self testServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) BIOS failed power-on self test
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputePhysicalBiosPostTimeout
moClass: compute:Physical
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalDiscoveryFailed
Fault Code: F0314
Message
Server [id] (service profile: [assignedToDn]) discovery: [discovery]Server [chassisId]/[slotId] (service profile: [assignedToDn]) discovery: [discovery]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) discovery: [discovery]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalDiscoveryFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssociationFailed
Fault Code: F0315
Message
Service profile [assignedToDn] failed to associate with server [id]Service profile [assignedToDn] failed to associate with server [chassisId]/[slotId]Service profile [assignedToDn] failed to associate with server [chassisId]/[slotId]/[serverInstanceId]
Explanation
Recommended Action
Fault Details
Cause: association-failed
mibFaultName: fltComputePhysicalAssociationFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalInoperable
Fault Code: F0317
Message
Server [id] (service profile: [assignedToDn]) health: [operability]Server [chassisId]/[slotId] (service profile: [assignedToDn]) health: [operability]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) health: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputePhysicalInoperable
moClass: compute:Physical
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnassignedMissing
Fault Code: F0318
Message
Server [id] (no profile) missingServer [chassisId]/[slotId] (no profile) missingServer [chassisId]/[slotId]/[serverInstanceId] (no profile) missing
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalUnassignedMissing
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssignedMissing
Fault Code: F0319
Message
Server [id] (service profile: [assignedToDn]) missingServer [chassisId]/[slotId] (service profile: [assignedToDn]) missingServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) missing
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalAssignedMissing
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnidentified
Fault Code: F0320
Message
Server [id] (service profile: [assignedToDn]) has an invalid FRU: [presence]Server [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU: [presence]Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has an invalid FRU: [presence]
Explanation
Recommended Action
Fault Details
Cause: identity-unestablishable
mibFaultName: fltComputePhysicalUnidentified
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalUnassignedInaccessible
Fault Code: F0321
Message
Server [id] (no profile) inaccessibleServer [chassisId]/[slotId] (no profile) inaccessibleServer [chassisId]/[slotId]/[serverInstanceId] (no profile) inaccessible
Explanation
Recommended Action
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalUnassignedInaccessible
moClass: compute:Physical
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalAssignedInaccessible
Fault Code: F0322
Message
Server [id] (service profile: [assignedToDn]) inaccessibleServer [chassisId]/[slotId] (service profile: [assignedToDn]) inaccessibleServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) inaccessible
Explanation
Recommended Action
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltComputePhysicalAssignedInaccessible
moClass: compute:Physical
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltLsServerFailed
Fault Code: F0324
Message
Service profile [name] failed
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsServerFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerDiscoveryFailed
Fault Code: F0326
Message
Service profile [name] discovery failed
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsServerDiscoveryFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerConfigFailure
Fault Code: F0327
Message
Service profile [name] configuration failed due to [configQualifier]
Explanation
Recommended Action
Fault Details
Cause: configuration-failure
mibFaultName: fltLsServerConfigFailure
Callhome Type: diagnostic
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerMaintenanceFailed
Fault Code: F0329
Message
Service profile [name] maintenance failed
Explanation
Recommended Action
Fault Details
Cause: maintenance-failed
mibFaultName: fltLsServerMaintenanceFailed
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerRemoved
Fault Code: F0330
Message
Service profile [name] underlying resource removed
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsServerRemoved
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerInaccessible
Fault Code: F0331
Message
Service profile [name] cannot be accessed
Explanation
Recommended Action
Fault Details
Cause: server-inaccessible
mibFaultName: fltLsServerInaccessible
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerAssociationFailed
Fault Code: F0332
Message
Service profile [name] association failed for [pnDn]
Explanation
Recommended Action
Fault Details
Cause: association-failed
mibFaultName: fltLsServerAssociationFailed
Callhome Type: diagnostic
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerUnassociated
Fault Code: F0334
Message
Service profile [name] is not associated
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsServerUnassociated
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsServerServer-unfulfilled
Fault Code: F0337
Message
Server [pnDn] does not fulfill Service profile [name] due to [configQualifier]
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsServerServerUnfulfilled
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltEtherSwitchIntFIoSatellite-connection-absent
Fault Code: F0367
Message
No link between NIF port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]
Explanation
Recommended Action
Fault Details
Cause: satellite-connection-absent
mibFaultName: fltEtherSwitchIntFIoSatelliteConnectionAbsent
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEtherSwitchIntFIoSatellite-wiring-problem
Fault Code: F0368
Message
Invalid connection between IOM port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]
Explanation
Recommended Action
Fault Details
Cause: satellite-mis-connected
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringProblem
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltEquipmentPsuPowerSupplyProblem
Fault Code: F0369
Message
Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuPowerSupplyProblem
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanDegraded
Fault Code: F0371
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltEquipmentFanDegraded
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanInoperable
Fault Code: F0373
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentFanInoperable
Callhome Type: environmental
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentPsuInoperable
Fault Code: F0374
Message
Power supply [id] in chassis [id] operability: [operability]Power supply [id] in fabric interconnect [id] operability: [operability]Power supply [id] in fex [id] operability: [operability]Power supply [id] in server [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentPsuInoperable
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentIOCardRemoved
Fault Code: F0376
Message
[side] IOM [chassisId]/[id] ([switchId]) is removed
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardRemoved
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleMissing
Fault Code: F0377
Message
Fan module [tray]-[id] in chassis [id] presence: [presence]Fan module [tray]-[id] in server [id] presence: [presence]Fan module [tray]-[id] in fabric interconnect [id] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFanModuleMissing
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuMissing
Fault Code: F0378
Message
Power supply [id] in chassis [id] presence: [presence]Power supply [id] in fabric interconnect [id] presence: [presence]Power supply [id] in fex [id] presence: [presence]Power supply [id] in server [id] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuMissing
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentIOCardThermalProblem
Fault Code: F0379
Message
[side] IOM [chassisId]/[id] ([switchId]) operState: [operState]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardThermalProblem
moClass: equipment:IOCard
Callhome Type: environmental
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleThermalThresholdNonCritical
Fault Code: F0380
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdNonCritical
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdNonCritical
Fault Code: F0381
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanModuleThermalThresholdCritical
Fault Code: F0382
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdCritical
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdCritical
Fault Code: F0383
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdCritical
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanModuleThermalThresholdNonRecoverable
Fault Code: F0384
Message
Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFanModuleThermalThresholdNonRecoverable
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuThermalThresholdNonRecoverable
Fault Code: F0385
Message
Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuThermalThresholdNonRecoverable
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdNonCritical
Fault Code: F0387
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdCritical
Fault Code: F0389
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdCritical
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuVoltageThresholdNonRecoverable
Fault Code: F0391
Message
Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuVoltageThresholdNonRecoverable
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdNonCritical
Fault Code: F0392
Message
Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdNonCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdCritical
Fault Code: F0393
Message
Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdCritical
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPerfThresholdNonRecoverable
Fault Code: F0394
Message
Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentPsuPerfThresholdNonRecoverable
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentFanPerfThresholdNonCritical
Fault Code: F0395
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdNonCritical
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanPerfThresholdCritical
Fault Code: F0396
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdCritical
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentFanPerfThresholdNonRecoverable
Fault Code: F0397
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdNonRecoverable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentIOCardFirmwareUpgrade
Fault Code: F0398
Message
Chassis controller in IOM [chassisId]/[id] ([switchId]) firmware upgrade problem: [upgradeStatus]
Explanation
Recommended Action
Fault Details
Cause: firmware-upgrade-problem
mibFaultName: fltEquipmentIOCardFirmwareUpgrade
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisUnsupportedConnectivity
Fault Code: F0399
Message
Current connectivity for chassis [id] does not match supported topology
Explanation
Recommended Action
Fault Details
Cause: unsupported-connectivity-configuration
mibFaultName: fltEquipmentChassisUnsupportedConnectivity
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisUnacknowledged
Fault Code: F0400
Message
Chassis [id] connectivity configuration: [configState]
Explanation
Recommended Action
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentChassisUnacknowledged
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentIOCardUnsupportedConnectivity
Fault Code: F0401
Message
IOM [chassisId]/[id] ([switchId]) current connectivity does not match discovery policy or connectivity is unsupported: [configState]
Explanation
Recommended Action
Fault Details
Cause: unsupported-connectivity-configuration
mibFaultName: fltEquipmentIOCardUnsupportedConnectivity
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardUnacknowledged
Fault Code: F0402
Message
IOM [chassisId]/[id] ([switchId]) connectivity configuration: [configState]
Explanation
Recommended Action
Fault Details
Cause: equipment-unacknowledged
mibFaultName: fltEquipmentIOCardUnacknowledged
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardPeerDisconnected
Fault Code: F0403
Message
IOM [chassisId]/[id] ([switchId]) peer connectivity: [peerCommStatus]
Explanation
Recommended Action
Fault Details
Cause: equipment-disconnected
mibFaultName: fltEquipmentIOCardPeerDisconnected
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisIdentity
Fault Code: F0404
Message
Chassis [id] has a mismatch between FRU identity reported by Fabric/IOM vs. FRU identity reported by CMC
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentChassisIdentity
moClass: equipment:Chassis
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]
fltEquipmentIOCardIdentity
Fault Code: F0405
Message
[side] IOM [chassisId]/[id] ([switchId]) has a malformed FRU
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardIdentity
moClass: equipment:IOCard
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanModuleIdentity
Fault Code: F0406
Message
Fan Module [tray]-[id] in chassis [id] has a malformed FRUFan Module [tray]-[id] in server [id] has a malformed FRUFan Module [tray]-[id] in fabric interconnect [id] has a malformed FRU
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFanModuleIdentity
moClass: equipment:FanModule
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentPsuIdentity
Fault Code: F0407
Message
Power supply [id] on chassis [id] has a malformed FRUPower supply [id] on server [id] has a malformed FRU
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuIdentity
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentChassisPowerProblem
Fault Code: F0408
Message
Power state on chassis [id] is [power]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentChassisPowerProblem
moClass: equipment:Chassis
Callhome Type: environmental
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdCritical
Fault Code: F0409
Message
Thermal condition on chassis [id] is [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdCritical
moClass: equipment:Chassis
Callhome Type: environmental
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdNonCritical
Fault Code: F0410
Message
Thermal condition on chassis [id] is [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdNonCritical
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentChassisThermalThresholdNonRecoverable
Fault Code: F0411
Message
Thermal condition on chassis [id] is [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentChassisThermalThresholdNonRecoverable
moClass: equipment:Chassis
Callhome Type: environmental
Affected MO: sys/chassis-[id]
fltComputeBoardCmosVoltageThresholdCritical
Fault Code: F0424
Message
Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId]/[serverInstanceId] is [cmosVoltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeBoardCmosVoltageThresholdCritical
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputeBoardCmosVoltageThresholdNonRecoverable
Fault Code: F0425
Message
Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId]/[serverInstanceId] is [cmosVoltage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeBoardCmosVoltageThresholdNonRecoverable
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltMgmtEntityElection-failure
Fault Code: F0428
Message
Fabric Interconnect [id], election of primary managemt instance has failed
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtEntityElectionFailure
Callhome Type: diagnostic
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityHa-not-ready
Fault Code: F0429
Message
Fabric Interconnect [id], HA functionality not ready
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtEntityHaNotReady
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityVersion-incompatible
Fault Code: F0430
Message
Fabric Interconnect [id], management services, incompatible versions
Explanation
Recommended Action
Fault Details
Cause: version-incompatible
mibFaultName: fltMgmtEntityVersionIncompatible
Callhome Type: diagnostic
Affected MO: sys/mgmt-entity-[id]
fltEquipmentFanMissing
Fault Code: F0434
Message
Fan [id] in fabric interconnect [id] presence: [presence]Fan [id] in fex [id] presence: [presence]Fan [id] in Fan Module [tray]-[id] under server [id] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFanMissing
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltEquipmentIOCardAutoUpgradingFirmware
Fault Code: F0435
Message
IOM [chassisId]/[id] ([switchId]) is auto upgrading firmware
Explanation
Recommended Action
Fault Details
Cause: auto-firmware-upgrade
mibFaultName: fltEquipmentIOCardAutoUpgradingFirmware
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltFirmwarePackItemImageMissing
Fault Code: F0436
Message
[type] image with vendor [hwVendor], model [hwModel] and version [version] is deleted
Explanation
Recommended Action
Fault Details
mibFaultName: fltFirmwarePackItemImageMissing
moClass: firmware:PackItem
Affected MO: org-[name]/fw-catalog-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-host-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-infra-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-mgmt-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/pack-image-[hwVendor]|[hwModel]|[type]
fltEtherSwitchIntFIoSatellite-wiring-numbers-unexpected
Fault Code: F0440
Message
Chassis discovery policy conflict: Link IOM [chassisId]/[slotId]/[portId] to fabric interconnect [switchId]:[peerSlotId]/[peerPortId] not configured
Explanation
Recommended Action
Fault Details
Cause: unexpected-number-of-links
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringNumbersUnexpected
moClass: ether:SwitchIntFIo
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltMgmtEntityManagement-services-failure
Fault Code: F0451
Message
Fabric Interconnect [id], management services have failed
Explanation
Recommended Action
Fault Details
Cause: management-services-failure
mibFaultName: fltMgmtEntityManagementServicesFailure
Callhome Type: diagnostic
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityManagement-services-unresponsive
Fault Code: F0452
Message
Fabric Interconnect [id], management services are unresponsive
Explanation
Recommended Action
Fault Details
Cause: management-services-unresponsive
mibFaultName: fltMgmtEntityManagementServicesUnresponsive
Callhome Type: diagnostic
Affected MO: sys/mgmt-entity-[id]
fltEquipmentChassisInoperable
Fault Code: F0456
Message
Chassis [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentChassisInoperable
moClass: equipment:Chassis
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]
fltEtherServerIntFIoHardware-failure
Fault Code: F0458
Message
IOM [transport] interface [portId] on chassis [id] oper state: [operState], reason: [stateQual]Fabric Interconnect [transport] interface [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]IOM [transport] interface [portId] on fex [id] oper state: [operState], reason: [stateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEtherServerIntFIoHardwareFailure
moClass: ether:ServerIntFIo
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/diag/port-[portId]
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/rack-unit-[id]/diag/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltDcxVcMgmt-vif-down
Fault Code: F0459
Message
IOM [chassisId] / [slotId] ([switchId]) management VIF [id] down, reason [stateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltDcxVcMgmtVifDown
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]
fltSysdebugMEpLogMEpLogLog
Fault Code: F0460
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId]/[serverInstanceId] is [capacity]
Explanation
Recommended Action
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogLog
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltSysdebugMEpLogMEpLogVeryLow
Fault Code: F0461
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId]/[serverInstanceId] is [capacity]
Explanation
Recommended Action
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogVeryLow
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltSysdebugMEpLogMEpLogFull
Fault Code: F0462
Message
Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId]/[serverInstanceId] is [capacity]
Explanation
Recommended Action
Fault Details
mibFaultName: fltSysdebugMEpLogMEpLogFull
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltComputePoolEmpty
Fault Code: F0463
Message
server pool [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePoolEmpty
Affected MO: org-[name]/compute-pool-[name]
fltUuidpoolPoolEmpty
Fault Code: F0464
Message
UUID suffix pool [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltUuidpoolPoolEmpty
Affected MO: org-[name]/uuid-pool-[name]
fltIppoolPoolEmpty
Fault Code: F0465
Message
IP pool [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltIppoolPoolEmpty
Affected MO: fabric/lan/network-sets/ip-pool-[name]
Affected MO: org-[name]/ip-pool-[name]
fltMacpoolPoolEmpty
Fault Code: F0466
Message
MAC pool [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltMacpoolPoolEmpty
Affected MO: org-[name]/mac-pool-[name]
fltFirmwareUpdatableImageUnusable
Fault Code: F0470
Message
backup image is unusable. reason: [operStateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFirmwareUpdatableImageUnusable
moClass: firmware:Updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/mgmt/fw-updatable
Affected MO: sys/switch-[id]/mgmt/fw-updatable
fltFirmwareBootUnitCantBoot
Fault Code: F0471
Message
unable to boot the startup image. End point booted with backup image
Explanation
Recommended Action
Fault Details
mibFaultName: fltFirmwareBootUnitCantBoot
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltFcpoolInitiatorsEmpty
Fault Code: F0476
Message
FC pool [purpose] [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltFcpoolInitiatorsEmpty
moClass: fcpool:Initiators
Affected MO: org-[name]/wwn-pool-[name]
fltEquipmentIOCardInaccessible
Fault Code: F0478
Message
[side] IOM [chassisId]/[id] ([switchId]) is inaccessible
Explanation
Recommended Action
Fault Details
Cause: equipment-inaccessible
mibFaultName: fltEquipmentIOCardInaccessible
moClass: equipment:IOCard
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltDcxVIfLinkState
Fault Code: F0479
Message
Virtual interface [id] link state is down
Explanation
Recommended Action
Fault Details
mibFaultName: fltDcxVIfLinkState
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-service-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vif-[id]
fltEquipmentFanModuleDegraded
Fault Code: F0480
Message
Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltEquipmentFanModuleDegraded
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltEquipmentIOCardPost-failure
Fault Code: F0481
Message
[side] IOM [chassisId]/[id] ([switchId]) POST failure
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardPostFailure
moClass: equipment:IOCard
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentFanPerfThresholdLowerNonRecoverable
Fault Code: F0484
Message
Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]
Explanation
Recommended Action
Fault Details
Cause: performance-problem
mibFaultName: fltEquipmentFanPerfThresholdLowerNonRecoverable
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]
fltMemoryUnitIdentity-unestablishable
Fault Code: F0502
Message
DIMM [location] on server [chassisId]/[slotId] has an invalid FRUDIMM [location] on server [id] has an invalid FRUDIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] has an invalid FRU
Explanation
Recommended Action
Fault Details
Cause: identity-unestablishable
mibFaultName: fltMemoryUnitIdentityUnestablishable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltComputePhysicalPost-failure
Fault Code: F0517
Message
Server [id] POST or diagnostic failureServer [chassisId]/[slotId] POST or diagnostic failureServer [chassisId]/[slotId]/[serverInstanceId] POST or diagnostic failure
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalPostFailure
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltEquipmentPsuOffline
Fault Code: F0528
Message
Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuOffline
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltStorageRaidBatteryInoperable
Fault Code: F0531
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageRaidBatteryInoperable
moClass: storage:RaidBattery
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltSysdebugMEpLogTransferError
Fault Code: F0532
Message
Server [chassisId]/[slotId] [type] transfer failed: [operState]Server [id] [type] transfer failed: [operState]
Explanation
Recommended Action
Fault Details
Cause: file-transfer-failed
mibFaultName: fltSysdebugMEpLogTransferError
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]
fltComputeRtcBatteryInoperable
Fault Code: F0533
Message
RTC Battery on server [chassisId]/[slotId] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltComputeRtcBatteryInoperable
moClass: compute:RtcBattery
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/rtc-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/rtc-battery
Affected MO: sys/rack-unit-[id]/board/rtc-battery
fltMemoryBufferUnitThermalThresholdNonCritical
Fault Code: F0535
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]Buffer Unit [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdNonCritical
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltMemoryBufferUnitThermalThresholdCritical
Fault Code: F0536
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]Buffer Unit [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdCritical
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltMemoryBufferUnitThermalThresholdNonRecoverable
Fault Code: F0537
Message
Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]Buffer Unit [id] on server [chassisId]/[slotId]/[serverInstanceId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMemoryBufferUnitThermalThresholdNonRecoverable
moClass: memory:BufferUnit
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]
fltComputeIOHubThermalNonCritical
Fault Code: F0538
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeIOHubThermalNonCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltComputeIOHubThermalThresholdCritical
Fault Code: F0539
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeIOHubThermalThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltComputeIOHubThermalThresholdNonRecoverable
Fault Code: F0540
Message
IO Hub on server [chassisId]/[slotId] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeIOHubThermalThresholdNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub
fltEquipmentChassisIdentity-unestablishable
Fault Code: F0543
Message
Chassis [id] has an invalid FRU
Explanation
Recommended Action
Fault Details
Cause: identity-unestablishable
mibFaultName: fltEquipmentChassisIdentityUnestablishable
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltSwVlanPortNsResourceStatus
Fault Code: F0549
Message
Vlan-Port Resource exceeded
Explanation
Recommended Action
Fault Details
mibFaultName: fltSwVlanPortNsResourceStatus
Callhome Type: diagnostic
Affected MO: sys/switch-[id]/vlan-port-ns
fltFabricLanPinGroupEmpty
Fault Code: F0621
Message
LAN Pin Group [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricLanPinGroupEmpty
moClass: fabric:LanPinGroup
Affected MO: fabric/lan/lan-pin-group-[name]
fltFabricSanPinGroupEmpty
Fault Code: F0622
Message
SAN Pin Group [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricSanPinGroupEmpty
moClass: fabric:SanPinGroup
Affected MO: fabric/san/san-pin-group-[name]
fltAdaptorExtEthIfMisConnect
Fault Code: F0625
Message
Adapter [id] eth interface [id] in server [id] mis-connected
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorExtEthIfMisConnect
moClass: adaptor:ExtEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltAdaptorHostEthIfMisConnect
Fault Code: F0626
Message
Adapter [id] eth interface [id] in server [id] mis-connected
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorHostEthIfMisConnect
moClass: adaptor:HostEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
fltPowerBudgetPowerBudgetCmcProblem
Fault Code: F0635
Message
Power cap application failed for chassis [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetCmcProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerBudgetPowerBudgetBmcProblem
Fault Code: F0637
Message
Power cap application failed for server [chassisId]/[slotId]Power cap application failed for server [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetBmcProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerBudgetPowerBudgetDiscFail
Fault Code: F0640
Message
Insufficient power available to discover server [chassisId]/[slotId]Insufficient power available to discover server [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerBudgetPowerBudgetDiscFail
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerGroupPowerGroupInsufficientBudget
Fault Code: F0642
Message
insufficient budget for power group [name]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerGroupPowerGroupInsufficientBudget
Affected MO: sys/power-ep/group-[name]
fltPowerGroupPowerGroupBudgetIncorrect
Fault Code: F0643
Message
admin committed insufficient for power group [name], using previous value [operCommitted]
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerGroupPowerGroupBudgetIncorrect
Affected MO: sys/power-ep/group-[name]
fltLicenseInstanceGracePeriodWarning1
Fault Code: F0670
Message
license for [feature] on fabric-interconnect [scope] has entered into the grace period.
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-entered
mibFaultName: fltLicenseInstanceGracePeriodWarning1
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning2
Fault Code: F0671
Message
license for [feature] on fabric-interconnect [scope] is running in the grace period for more than 10 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-10days
mibFaultName: fltLicenseInstanceGracePeriodWarning2
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning3
Fault Code: F0672
Message
license for [feature] on fabric-interconnect [scope] is running in the grace period for more than 30 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-30days
mibFaultName: fltLicenseInstanceGracePeriodWarning3
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning4
Fault Code: F0673
Message
license for [feature] on fabric-interconnect [scope] is running in the grace period for more than 60 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-60days
mibFaultName: fltLicenseInstanceGracePeriodWarning4
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning5
Fault Code: F0674
Message
license for [feature] on fabric-interconnect [scope] is running in the grace period for more than 90 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-90days
mibFaultName: fltLicenseInstanceGracePeriodWarning5
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning6
Fault Code: F0675
Message
license for [feature] on fabric-interconnect [scope] is running in the grace period for more than 119 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-119days
mibFaultName: fltLicenseInstanceGracePeriodWarning6
moClass: license:Instance
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseInstanceGracePeriodWarning7
Fault Code: F0676
Message
Grace period for [feature] on fabric-interconnect [scope] is expired. Please acquire a license for the same.
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-expired
mibFaultName: fltLicenseInstanceGracePeriodWarning7
moClass: license:Instance
Callhome Type: environmental
Affected MO: sys/license/feature-[name]-[vendor]-[version]/inst-[scope]
fltLicenseFileBadLicenseFile
Fault Code: F0677
Message
license file [name] on fabric-interconnect [scope] can not be installed
Explanation
Recommended Action
Fault Details
Cause: license-file-uninstallable
mibFaultName: fltLicenseFileBadLicenseFile
Affected MO: sys/license/file-[scope]:[id]
fltLicenseFileFileNotDeleted
Fault Code: F0678
Message
license file [name] from fabric-interconnect [scope] could not be deleted
Explanation
Recommended Action
Fault Details
Cause: license-file-not-deleted
mibFaultName: fltLicenseFileFileNotDeleted
Affected MO: sys/license/file-[scope]:[id]
fltMgmtIfMisConnect
Fault Code: F0688
Message
Management Port [id] in server [id] is mis connected
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtIfMisConnect
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltLsComputeBindingAssignmentRequirementsNotMet
Fault Code: F0689
Message
Assignment of service profile [name] to server [pnDn] failed
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsComputeBindingAssignmentRequirementsNotMet
moClass: ls:ComputeBinding
Affected MO: org-[name]/ls-[name]/pn
Affected MO: org-[name]/ls-[name]/pn-req
Affected MO: org-[name]/tier-[name]/ls-[name]/pn
Affected MO: org-[name]/tier-[name]/ls-[name]/pn-req
fltEquipmentFexPost-failure
Fault Code: F0702
Message
fex [id] POST failure
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFexPostFailure
Callhome Type: diagnostic
Affected MO: sys/fex-[id]
fltEquipmentFexIdentity
Fault Code: F0703
Message
Fex [id] has a malformed FRU
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFexIdentity
Callhome Type: diagnostic
Affected MO: sys/fex-[id]
fltAdaptorHostEthIfMissing
Fault Code: F0708
Message
Connection to Adapter [id] eth interface [id] in server [id] missing
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorHostEthIfMissing
moClass: adaptor:HostEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
fltPortPIoInvalid-sfp
Fault Code: F0713
Message
[transport] port [portId] on chassis [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType]
Explanation
Recommended Action
Fault Details
Cause: unsupported-transceiver
mibFaultName: fltPortPIoInvalidSfp
Affected MO: sys/chassis-[id]/shared-io-module/[type]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]
fltMgmtIfMissing
Fault Code: F0717
Message
Connection to Management Port [id] in server [id] is missing
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtIfMissing
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltFabricEthLanPcEpDown
Fault Code: F0727
Message
[type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricEthLanPcEpDown
moClass: fabric:EthLanPcEp
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltFabricFcSanPcEpDown
Fault Code: F0728
Message
[type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcSanPcEpDown
moClass: fabric:FcSanPcEp
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltEquipmentIOCardThermalThresholdNonCritical
Fault Code: F0729
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdNonCritical
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardThermalThresholdCritical
Fault Code: F0730
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdCritical
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentIOCardThermalThresholdNonRecoverable
Fault Code: F0731
Message
[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentIOCardThermalThresholdNonRecoverable
moClass: equipment:IOCard
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]
fltEquipmentChassisSeeprom-inoperable
Fault Code: F0733
Message
Device [id] SEEPROM operability: [seepromOperState]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentChassisSeepromInoperable
moClass: equipment:Chassis
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]
fltFabricFcSanPcEpIncompatibleSpeed
Fault Code: F0734
Message
Member [slotId]/[portId] cannot be added to SAN Port-Channel [portId] on fabric interconnect [id], reason: [membership]
Explanation
Recommended Action
Fault Details
Cause: incompatible-speed
mibFaultName: fltFabricFcSanPcEpIncompatibleSpeed
moClass: fabric:FcSanPcEp
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltFabricFcSanPcIncompatibleSpeed
Fault Code: F0735
Message
Cannot set admin speed to the requested value, Speed incompatible with member ports in the port-channel
Explanation
Recommended Action
Fault Details
Cause: incompatible-speed
mibFaultName: fltFabricFcSanPcIncompatibleSpeed
Affected MO: fabric/san/[id]/pc-[portId]
fltExtmgmtIfMgmtifdown
Fault Code: F0736
Message
Management interface on Fabric Interconnect [id] is [operState]
Explanation
Recommended Action
Fault Details
mibFaultName: fltExtmgmtIfMgmtifdown
Callhome Type: diagnostic
Affected MO: sys/switch-[id]/extmgmt-intf
fltPowerChassisMemberPowerGroupCapInsufficient
Fault Code: F0740
Message
Chassis [id] cannot be capped as group cap is low. Please consider raising the cap.
Explanation
Recommended Action
Fault Details
Cause: group-cap-insufficient
mibFaultName: fltPowerChassisMemberPowerGroupCapInsufficient
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisFirmwareProblem
Fault Code: F0741
Message
Chassis [id] cannot be capped as at least one of the CMC or CIMC or BIOS firmware version is less than 1.4. Please upgrade the firmware for cap to be applied.
Explanation
Recommended Action
Fault Details
Cause: old-chassis-component-firmware
mibFaultName: fltPowerChassisMemberChassisFirmwareProblem
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisPsuInsufficient
Fault Code: F0742
Message
Chassis [id] cannot be capped as at least two PSU need to be powered
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerChassisMemberChassisPsuInsufficient
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerChassisMemberChassisPsuRedundanceFailure
Fault Code: F0743
Message
Chassis [id] was configured for redundancy, but running in a non-redundant configuration.
Explanation
Recommended Action
Fault Details
Cause: psu-redundancy-fail
mibFaultName: fltPowerChassisMemberChassisPsuRedundanceFailure
moClass: power:ChassisMember
Affected MO: sys/power-ep/group-[name]/ch-member-[id]
fltPowerBudgetPowerCapReachedCommit
Fault Code: F0744
Message
P-State lowered as consumption hit power cap for server [chassisId]/[slotId]P-State lowered as consumption hit power cap for server [id]
Explanation
Recommended Action
Fault Details
Cause: power-consumption-hit-limit
mibFaultName: fltPowerBudgetPowerCapReachedCommit
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
Fault Code: F0747
Message
Auto core transfer failure at remote server [hostname]:[path] [exportFailureReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
moClass: sysdebug:AutoCoreFileExportTarget
Affected MO: sys/sysdebug/file-export
fltFabricMonSpanConfigFail
Fault Code: F0757
Message
Configuration for traffic monitor [name] failed, reason: [configFailReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricMonSpanConfigFail
Affected MO: fabric/lanmon/[id]/eth-mon-[name]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]
fltPowerBudgetChassisPsuInsufficient
Fault Code: F0764
Message
Chassis [id] has had PSU failures. Please correct the problem by checking input power or replace the PSU
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerBudgetChassisPsuInsufficient
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerBudgetTStateTransition
Fault Code: F0765
Message
Blade [chassisId]/[slotId] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliantRack server [id] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerBudgetTStateTransition
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltPowerPolicyPowerPolicyApplicationFail
Fault Code: F0766
Message
Insufficient budget to apply no-cap priority through policy [name]. Blades will continue to be capped
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerPolicyPowerPolicyApplicationFail
Affected MO: org-[name]/power-policy-[name]
fltMgmtIfNew
Fault Code: F0772
Message
New connection discovered on Management Port [id] in server [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtIfNew
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]
fltAdaptorExtEthIfMissing
Fault Code: F0775
Message
Connection to Adapter [id] eth interface [id] in server [id] missing
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorExtEthIfMissing
moClass: adaptor:ExtEthIf
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]
fltStorageLocalDiskSlotEpUnusable
Fault Code: F0776
Message
Local disk [id] on server [serverId] is not usable by the operating system
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageLocalDiskSlotEpUnusable
moClass: storage:LocalDiskSlotEp
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/disk-[id]
Affected MO: sys/rack-unit-[id]/board/disk-[id]
fltFabricEthEstcPcEpDown
Fault Code: F0777
Message
[type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricEthEstcPcEpDown
moClass: fabric:EthEstcPcEp
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltEquipmentFexIdentity-unestablishable
Fault Code: F0778
Message
Fex [id] has an invalid FRU
Explanation
Recommended Action
Fault Details
Cause: identity-unestablishable
mibFaultName: fltEquipmentFexIdentityUnestablishable
Affected MO: sys/fex-[id]
fltEquipmentFanModuleInoperable
Fault Code: F0794
Message
Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltEquipmentFanModuleInoperable
moClass: equipment:FanModule
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]
fltLsmaintMaintPolicyUnresolvableScheduler
Fault Code: F0795
Message
Schedule [schedName] referenced by maintenance policy [name] does not exist
Explanation
Recommended Action
Fault Details
Cause: non-existent-scheduler
mibFaultName: fltLsmaintMaintPolicyUnresolvableScheduler
moClass: lsmaint:MaintPolicy
Affected MO: org-[name]/maint-[name]
fltFabricVsanErrorDisabled
Fault Code: F0796
Message
VSAN [name] is [operState]
Explanation
Recommended Action
Fault Details
Cause: vsan-misconfigured
mibFaultName: fltFabricVsanErrorDisabled
Affected MO: fabric/fc-estc/[id]/net-[name]
Affected MO: fabric/fc-estc/net-[name]
Affected MO: fabric/san/[id]/net-[name]
Affected MO: fabric/san/net-[name]
fltFabricVsanEpErrorDisabled
Fault Code: F0797
Message
[type] Port [slotId]/[portId] on fabric interconnect [switchId] has VSAN [id] in error disabled statePort channel [portId] on fabric interconnect [switchId] has VSAN [id] in error disabled state
Explanation
Recommended Action
Fault Details
Cause: vsan-misconfigured
mibFaultName: fltFabricVsanEpErrorDisabled
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/pc-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsan-[id]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]/vsan-[id]
fltPowerBudgetFirmwareMismatch
Fault Code: F0798
Message
Firmware on blade [chassisId]/[slotId] does not allow chassis level power capping. Please consider upgrading to at least 1.4 version
Explanation
Recommended Action
Fault Details
mibFaultName: fltPowerBudgetFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/budget
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget
fltProcessorUnitIdentity-unestablishable
Fault Code: F0801
Message
Processor [id] on server [chassisId]/[slotId] has an invalid FRUProcessor [id] on server [id] has an invalid FRUProcessor [id] on server [chassisId]/[slotId]/[serverInstanceId] has an invalid FRU
Explanation
Recommended Action
Fault Details
Cause: identity-unestablishable
mibFaultName: fltProcessorUnitIdentityUnestablishable
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltIqnpoolPoolEmpty
Fault Code: F0821
Message
iqn pool [name] is empty
Explanation
Recommended Action
Fault Details
mibFaultName: fltIqnpoolPoolEmpty
Affected MO: org-[name]/iqn-pool-[name]
fltFabricDceSwSrvPcEpDown
Fault Code: F0831
Message
[type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricDceSwSrvPcEpDown
moClass: fabric:DceSwSrvPcEp
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltFabricEpMgrEpTransModeFail
Fault Code: F0832
Message
Port constraint violation on switch [id]: [confQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricEpMgrEpTransModeFail
fltFabricVlanMisconfigured
Fault Code: F0833
Message
VLAN [name] is [operState] because of conflicting vlan-id with a fcoe-vlan
Explanation
Recommended Action
Fault Details
Cause: vlan-misconfigured
mibFaultName: fltFabricVlanMisconfigured
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricPIoEpErrorMisconfigured
Fault Code: F0834
Message
Interface [name] is [operState]. Reason: [operStateReason]
Explanation
Recommended Action
Fault Details
Cause: interface-misconfigured
mibFaultName: fltFabricPIoEpErrorMisconfigured
Affected MO: fabric/eth-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/cart-ep-ven-[vendor]-mod-[model]-ser-[serial]
Affected MO: fabric/server/chassis-[chassisId]
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]/ins-[serverInstanceId]
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
Affected MO: fabric/server/chassis-ep-ven-[vendor]-mod[model]-ser-[serial]
Affected MO: fabric/server/compute-ep-ven-[vendor]-mod-[model]-ser-[serial]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-port-[portId]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/eth-target-[name]
fltFabricEthLanEpMissingPrimaryVlan
Fault Code: F0835
Message
Primary vlan missing from fabric: [switchId], port: [slotId]/[portId].
Explanation
Recommended Action
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltFabricEthLanEpMissingPrimaryVlan
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcMissingPrimaryVlan
Fault Code: F0836
Message
Primary vlan missing from fabric: [switchId], port-channel: [portId].
Explanation
Recommended Action
Fault Details
Cause: missing-primary-vlan
mibFaultName: fltFabricEthLanPcMissingPrimaryVlan
Affected MO: fabric/lan/[id]/pc-[portId]
fltVnicEtherPinningMismatch
Fault Code: F0840
Message
Hard pinning target for eth vNIC [name], service profile [name] does not have all the required vlans configured
Explanation
Recommended Action
Fault Details
mibFaultName: fltVnicEtherPinningMismatch
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltVnicEtherPinningMisconfig
Fault Code: F0841
Message
Hard pinning target for eth vNIC [name], service profile [name] is missing or misconfigured
Explanation
Recommended Action
Fault Details
mibFaultName: fltVnicEtherPinningMisconfig
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltProcessorUnitDisabled
Fault Code: F0842
Message
Processor [id] on server [chassisId]/[slotId] operState: [operState]Processor [id] on server [id] operState: [operState]Processor [id] on server [chassisId]/[slotId]/[serverInstanceId] operState: [operState]
Explanation
Recommended Action
Fault Details
Cause: equipment-disabled
mibFaultName: fltProcessorUnitDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]
fltMemoryUnitDisabled
Fault Code: F0844
Message
DIMM [location] on server [chassisId]/[slotId] operState: [operState]DIMM [location] on server [id] operaState: [operState]DIMM [location] on server [chassisId]/[slotId]/[serverInstanceId] operState: [operState]
Explanation
Recommended Action
Fault Details
Cause: equipment-disabled
mibFaultName: fltMemoryUnitDisabled
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]
fltFirmwareBootUnitActivateStatusFailed
Fault Code: F0856
Message
Activation failed and Activate Status set to failed.
Explanation
Recommended Action
Fault Details
mibFaultName: fltFirmwareBootUnitActivateStatusFailed
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltFabricInternalPcDown
Fault Code: F0858
Message
[type] port-channel [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]
Explanation
Recommended Action
Fault Details
Cause: operational-state-down
mibFaultName: fltFabricInternalPcDown
moClass: fabric:InternalPc
Affected MO: fabric/server/sw-[id]/pc-[portId]
fltMgmtEntityDevice-1-shared-storage-error
Fault Code: F0863
Message
device [chassis1], error accessing shared-storage
Explanation
Recommended Action
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice1SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-2-shared-storage error
Fault Code: F0864
Message
device [chassis2], error accessing shared-storage
Explanation
Recommended Action
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice2SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityDevice-3-shared-storage error
Fault Code: F0865
Message
device [chassis3], error accessing shared-storage
Explanation
Recommended Action
Fault Details
Cause: device-shared-storage-error
mibFaultName: fltMgmtEntityDevice3SharedStorageError
Affected MO: sys/mgmt-entity-[id]
fltMgmtEntityHa-ssh-keys-mismatched
Fault Code: F0866
Message
Fabric Interconnect [id], management services, mismatched SSH keys
Explanation
Recommended Action
Fault Details
Cause: ha-ssh-keys-mismatched
mibFaultName: fltMgmtEntityHaSshKeysMismatched
Affected MO: sys/mgmt-entity-[id]
fltMgmtPmonEntryUCSM process failure
Fault Code: F0867
Message
UCSM process [name] failed on FI [switchId]
Explanation
Recommended Action
Fault Details
Cause: ucsm-process-failure
mibFaultName: fltMgmtPmonEntryUCSMProcessFailure
Affected MO: sys/mgmt-entity-[id]/[name]
fltComputeBoardPowerFail
Fault Code: F0868
Message
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [power]Motherboard of server [id] (service profile: [assignedToDn]) power: [power]Motherboard of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) power: [power]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeBoardPowerFail
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/rack-unit-[id]/board
fltComputeABoardThermalProblem
Fault Code: F0869
Message
Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) thermal: [thermal]Motherboard of server [id] (service profile: [assignedToDn]) thermal: [thermal]Motherboard [faultQualifier] of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) thermal: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeABoardThermalProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltVmVifLinkState
Fault Code: F0876
Message
Virtual interface [vifId] link is down; reason [stateQual]
Explanation
Recommended Action
Fault Details
mibFaultName: fltVmVifLinkState
Affected MO: vmm/computeEp-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/hv-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/vm-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
fltEquipmentPsuPowerSupplyShutdown
Fault Code: F0881
Message
Power supply [id] in chassis [id] shutdown reason:[powerStateQualifier]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuPowerSupplyShutdown
Callhome Type: environmental
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuPowerThreshold
Fault Code: F0882
Message
Power supply [id] on chassis [id] has exceeded its power thresholdPower supply [id] on server [id] has exceeded its power threshold
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuPowerThreshold
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentPsuInputError
Fault Code: F0883
Message
Power supply [id] on chassis [id] has disconnected cable or bad input voltagePower supply [id] on server [id] has disconnected cable or bad input voltage
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentPsuInputError
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]
fltEquipmentSwitchCardPowerOff
Fault Code: F0884
Message
Switch card is powered down.
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentSwitchCardPowerOff
moClass: equipment:SwitchCard
Affected MO: sys/switch-[id]/slot-[id]
fltNetworkElementInventoryFailed
Fault Code: F0885
Message
Fabric Interconnect [id] inventory is not complete [inventoryStatus]
Explanation
Recommended Action
Fault Details
mibFaultName: fltNetworkElementInventoryFailed
Callhome Type: diagnostic
Affected MO: sys/switch-[id]
fltAdaptorUnitExtnUnidentifiable-fru
Fault Code: F0900
Message
Adapter extension [id] in server [chassisId]/[slotId] has unidentified FRU
Explanation
Recommended Action
Fault Details
Cause: unidentifiable-fru
mibFaultName: fltAdaptorUnitExtnUnidentifiableFru
moClass: adaptor:UnitExtn
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]
fltAdaptorUnitExtnMissing
Fault Code: F0901
Message
Adapter extension [id] in server [chassisId]/[slotId] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltAdaptorUnitExtnMissing
moClass: adaptor:UnitExtn
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]
fltEquipmentFexFex-unsupported
Fault Code: F0902
Message
Fex [id] with model [model] is unsupported
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFexFexUnsupported
Affected MO: sys/fex-[id]
fltVnicIScsiConfig-failed
Fault Code: F0903
Message
iSCSI vNIC [name], service profile [name] has duplicate iqn name [initiatorName]
Explanation
Recommended Action
Fault Details
Cause: configuration-failed
mibFaultName: fltVnicIScsiConfigFailed
Affected MO: org-[name]/ls-[name]/iscsi-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/iscsi-[name]
fltPkiKeyRingStatus
Fault Code: F0909
Message
[name] Keyring’s certificate is invalid, reason: [certStatus].
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-certificate
mibFaultName: fltPkiKeyRingStatus
Affected MO: sys/pki-ext/keyring-[name]
fltPkiTPStatus
Fault Code: F0910
Message
[name] Trustpoint’s cert-chain is invalid, reason: [certStatus].
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-trustpoint-cert-chain
mibFaultName: fltPkiTPStatus
Affected MO: sys/pki-ext/tp-[name]
fltComputePhysicalDisassociationFailed
Fault Code: F0915
Message
Failed to disassociate server [id]Failed to disassociate server [chassisId]/[slotId]Failed to disassociate server [chassisId]/[slotId]/[serverInstanceId]
Explanation
Recommended Action
Fault Details
Cause: disassociation-failed
mibFaultName: fltComputePhysicalDisassociationFailed
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltComputePhysicalNetworkMisconfigured
Fault Code: F0916
Message
Server [id] (service profile: [assignedToDn]) has mis-configured network vif resourcesServer [chassisId]/[slotId] (service profile: [assignedToDn]) has mis-configured network vif resourcesServer [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) has mis-configured network vif resources
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalNetworkMisconfigured
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltVnicProfileProfileConfigIncorrect
Fault Code: F0917
Message
The Port Profile [name] has an invalid configuration.
Explanation
Recommended Action
Fault Details
Cause: profile-config-incorrect
mibFaultName: fltVnicProfileProfileConfigIncorrect
Affected MO: fabric/lan/profiles/vnic-[name]
fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
Fault Code: F0918
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
Fault Code: F0919
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageUpperThresholdCritical
Fault Code: F0920
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageUpperThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltComputeABoardMotherBoardVoltageLowerThresholdCritical
Fault Code: F0921
Message
Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId]/[serverInstanceId] is [voltage]
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltComputeABoardMotherBoardVoltageLowerThresholdCritical
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltVnicEtherIfVlanAccessFault
Fault Code: F0932
Message
The named vlan [name] for vNIC [name] cannot be accessed from org [name]
Explanation
Recommended Action
Fault Details
Cause: inaccessible-vlan-referenced
mibFaultName: fltVnicEtherIfVlanAccessFault
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfVlanUnresolvable
Fault Code: F0933
Message
The named vlan [name] for vNIC [name] cannot be resolved
Explanation
Recommended Action
Fault Details
Cause: referenced-vlan-unresolvable
mibFaultName: fltVnicEtherIfVlanUnresolvable
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicEtherIfInvalidVlan
Fault Code: F0934
Message
Invalid Vlan in the allowed vlan list
Explanation
Recommended Action
Fault Details
Cause: invalid-vlan-in-the-allowed-vlan-list
mibFaultName: fltVnicEtherIfInvalidVlan
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltFabricVlanVlanConflictPermit
Fault Code: F0935
Message
There are multiple vlans with id [id] have different accessability configured.
Explanation
Recommended Action
Fault Details
Cause: vlan-conflict-permit
mibFaultName: fltFabricVlanVlanConflictPermit
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanReqVlanPermitUnresolved
Fault Code: F0936
Message
The VLAN permit does not reference any existing vlans.
Explanation
Recommended Action
Fault Details
Cause: vlan-permit-unresolved
mibFaultName: fltFabricVlanReqVlanPermitUnresolved
Affected MO: org-[name]/vlan-req-[name]
fltFabricVlanGroupReqVlanGroupPermitUnresolved
Fault Code: F0937
Message
The VLAN permit does not reference any existing net groups.
Explanation
Recommended Action
Fault Details
Cause: group-permit-unresolved
mibFaultName: fltFabricVlanGroupReqVlanGroupPermitUnresolved
moClass: fabric:VlanGroupReq
Affected MO: org-[name]/vlan-group-req-[name]
fltExtpolClientClientLostConnectivity
Fault Code: F0988
Message
UCS has lost connectivity with UCS Central
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: client-lost-connectivity
mibFaultName: fltExtpolClientClientLostConnectivity
Affected MO: extpol/reg/clients/client-[id]
fltStorageLocalDiskDegraded
Fault Code: F0996
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageLocalDiskDegraded
moClass: storage:LocalDisk
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageRaidBatteryDegraded
Fault Code: F0997
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryDegraded
moClass: storage:RaidBattery
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageRaidBatteryRelearnAborted
Fault Code: F0998
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryRelearnAborted
moClass: storage:RaidBattery
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageRaidBatteryRelearnFailed
Fault Code: F0999
Message
RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]RAID Battery on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageRaidBatteryRelearnFailed
moClass: storage:RaidBattery
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/chassis-[id]/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery
fltStorageADefConfiguration-error
Fault Code: F1000
Message
Vsan trunking is not supported on Vhbas. Targets with overlapping path should have same vsan.
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltStorageADefConfigurationError
Affected MO: org-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/fc-group/storage-conndef
Affected MO: org-[name]/storage-connpolicy-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef
fltStorageInitiatorConfiguration-error
Fault Code: F1001
Message
Initiator [name] either cannot be resolved or does not match with one of the storage targets. No zones are deployed for this initiator and the target.
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltStorageInitiatorConfigurationError
moClass: storage:Initiator
Affected MO: org-[name]/ls-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/ini-[name]
fltStorageVsanRefVsanUnresolvable
Fault Code: F1002
Message
The named vsan [name] for storage target cannot be resolved
Explanation
Recommended Action
Fault Details
Cause: referenced-vsan-unresolvable
mibFaultName: fltStorageVsanRefVsanUnresolvable
Affected MO: org-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef/fc-target-ep-[targetwwpn]/vsan-ref
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/fc-group/storage-conndef/fc-target-ep-[targetwwpn]/vsan-ref
Affected MO: org-[name]/storage-connpolicy-[name]/fc-target-ep-[targetwwpn]/vsan-ref
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/fc-group/storage-conndef/fc-target-ep-[targetwwpn]/vsan-ref
fltStorageControllerPatrolReadFailed
Fault Code: F1003
Message
Controller [id] on server [chassisId]/[slotId] had a patrol read failure. Reason: [operQualifierReason]Controller [id] on server [id] had a patrol read failure. Reason: [operQualifierReason]Controller [id] on chassis [id] had a patrol read failure. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageControllerPatrolReadFailed
moClass: storage:Controller
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageControllerInoperable
Fault Code: F1004
Message
Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]Controller [id] on server [id] is inoperable. Reason: [operQualifierReason]Controller [id] on chassis [id] is inoperable. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageControllerInoperable
moClass: storage:Controller
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageLocalDiskRebuildFailed
Fault Code: F1005
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageLocalDiskRebuildFailed
moClass: storage:LocalDisk
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageLocalDiskCopybackFailed
Fault Code: F1006
Message
Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageLocalDiskCopybackFailed
moClass: storage:LocalDisk
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageVirtualDriveInoperable
Fault Code: F1007
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageVirtualDriveInoperable
moClass: storage:VirtualDrive
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveDegraded
Fault Code: F1008
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveDegraded
moClass: storage:VirtualDrive
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveReconstructionFailed
Fault Code: F1009
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveReconstructionFailed
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveConsistencyCheckFailed
Fault Code: F1010
Message
Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on chassis [id] operability: [operability]. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageVirtualDriveConsistencyCheckFailed
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltAaaProviderGroupProvidergroup
Fault Code: F1026
Message
For [dn]: Server Group with name [name] already exist, You need to specify a unique name for this object.
Explanation
Recommended Action
Fault Details
Cause: provider-group-already-exists
mibFaultName: fltAaaProviderGroupProvidergroup
moClass: aaa:ProviderGroup
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]
fltAaaConfigServergroup
Fault Code: F1027
Message
For [dn]: [realm] Server Group with name [providerGroup] doesn’t exist or is not deployed.
Explanation
Recommended Action
Fault Details
Cause: invalid-server-group
mibFaultName: fltAaaConfigServergroup
Affected MO: sys/auth-realm/console-auth
Affected MO: sys/auth-realm/default-auth
Affected MO: sys/auth-realm/domain-[name]/domain-auth
fltAaaRoleRoleNotDeployed
Fault Code: F1028
Message
Role [name] can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltAaaRoleRoleNotDeployed
Affected MO: sys/user-ext/role-[name]
fltAaaLocaleLocaleNotDeployed
Fault Code: F1029
Message
Locale [name] can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
Cause: locale-config-error
mibFaultName: fltAaaLocaleLocaleNotDeployed
Affected MO: sys/user-ext/locale-[name]
fltAaaUserRoleUserRoleNotDeployed
Fault Code: F1030
Message
For user: [name] role [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] role [name] can’t be assigned. Error: [configStatusMessage].
Explanation
Recommended Action
Fault Details
Cause: user-role-config-error
mibFaultName: fltAaaUserRoleUserRoleNotDeployed
Affected MO: sys/ldap-ext/ldapgroup-[name]/role-[name]
Affected MO: sys/user-ext/remoteuser-[name]/role-[name]
Affected MO: sys/user-ext/user-[name]/role-[name]
fltAaaUserLocaleUserLocaleNotDeployed
Fault Code: F1031
Message
For user: [name] locale [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] locale [name] can’t be assigned. Error: [configStatusMessage].
Explanation
Recommended Action
Fault Details
Cause: user-locale-config-error
mibFaultName: fltAaaUserLocaleUserLocaleNotDeployed
Affected MO: sys/ldap-ext/ldapgroup-[name]/locale-[name]
Affected MO: sys/user-ext/remoteuser-[name]/locale-[name]
Affected MO: sys/user-ext/user-[name]/locale-[name]
fltPkiKeyRingKeyRingNotDeployed
Fault Code: F1032
Message
Keyring [name] can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
Cause: keyring-config-error
mibFaultName: fltPkiKeyRingKeyRingNotDeployed
Affected MO: sys/pki-ext/keyring-[name]
fltCommSnmpSyscontactEmpty
Fault Code: F1033
Message
UCS Manager cannot deploy an empty value of SNMP Syscontact when Callhome is enabled. The previous value [sysContact] for SNMP Syscontact has been retained.
Explanation
Recommended Action
Fault Details
mibFaultName: fltCommSnmpSyscontactEmpty
Affected MO: sys/svc-ext/snmp-svc
fltCommDateTimeCommTimeZoneInvalid
Fault Code: F1034
Message
Timezone:[timezone] is invalid
Explanation
Recommended Action
Fault Details
Cause: timezone-file-not-exists
mibFaultName: fltCommDateTimeCommTimeZoneInvalid
Affected MO: sys/svc-ext/datetime-svc
fltAaaUserLocalUserNotDeployed
Fault Code: F1035
Message
Local User [name] can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltAaaUserLocalUserNotDeployed
Affected MO: sys/user-ext/user-[name]
fltCommSnmpUserSnmpUserNotDeployed
Fault Code: F1036
Message
SNMP User [name] can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
Cause: snmp-user-config-error
mibFaultName: fltCommSnmpUserSnmpUserNotDeployed
Affected MO: sys/svc-ext/snmp-svc/snmpv3-user-[name]
fltCommSvcEpCommSvcNotDeployed
Fault Code: F1037
Message
Communication Service configuration can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
Cause: comm-svc-config-error
mibFaultName: fltCommSvcEpCommSvcNotDeployed
fltComputeABoardPowerUsageProblem
Fault Code: F1040
Message
Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) powerUsage: [powerUsage]Motherboard of server [id] (service profile: [assignedToDn]) powerUsage: [powerUsage]Motherboard [faultQualifier] of server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) powerUsage: [powerUsage]
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeABoardPowerUsageProblem
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]
fltSwVlanPortNsVLANCompNotSupport
Fault Code: F1056
Message
VLAN Port Count Optimization is not supported
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: no-vlan-optimization
mibFaultName: fltSwVlanPortNsVLANCompNotSupport
Affected MO: sys/switch-[id]/vlan-port-ns
fltPolicyControlEpSuspendModeActive
Fault Code: F1057
Message
UCSM is suspended from receiving updates from UCS Central.
Explanation
Recommended Action
Fault Details
Cause: suspend-mode-entered
mibFaultName: fltPolicyControlEpSuspendModeActive
moClass: policy:ControlEp
Affected MO: sys/control-ep-[type]
fltNetworkElementThermalThresholdCritical
Fault Code: F1080
Message
Fabric Interconnect [id] temperature: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltNetworkElementThermalThresholdCritical
Callhome Type: environmental
Affected MO: sys/switch-[id]
fltFabricFcoeSanPcEpDown
Fault Code: F1081
Message
[type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcoeSanPcEpDown
moClass: fabric:FcoeSanPcEp
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
fltFabricFcoeSanEpDown
Fault Code: F1082
Message
FCoE uplink port [slotId]/[portId] is down
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcoeSanEpDown
moClass: fabric:FcoeSanEp
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
fltFabricVsanMembershipDown
Fault Code: F1083
Message
FCoE or FC uplink is down on Vsan [vsanId]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricVsanMembershipDown
moClass: fabric:VsanMembership
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/pc-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]/vsanmember-[vsanId]
fltFabricFcoeSanEpUnsupported
Fault Code: F1084
Message
FCoE uplink port [slotId]/[portId] cannot be supported on springfields when FI is in eth endhost mode and FC switching mode
Explanation
Recommended Action
Fault Details
Cause: fcoe-uplink-unsupported-fi-settings
mibFaultName: fltFabricFcoeSanEpUnsupported
moClass: fabric:FcoeSanEp
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
fltFabricFcoeSanPcDown
Fault Code: F1085
Message
FCoE uplink port channel [portId] is down
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcoeSanPcDown
moClass: fabric:FcoeSanPc
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
fltFabricFcoeSanPcUnsupported
Fault Code: F1086
Message
FCoE uplink port channel [portId] cannot be supported on springfields when FI is in eth endhost mode and FC switching mode
Explanation
Recommended Action
Fault Details
Cause: fcoe-uplink-port-channel-unsupported-fi-settings
mibFaultName: fltFabricFcoeSanPcUnsupported
moClass: fabric:FcoeSanPc
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
fltFabricFcoeEstcEpDown
Fault Code: F1087
Message
FCoE storage port [slotId]/[portId] is down
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcoeEstcEpDown
moClass: fabric:FcoeEstcEp
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
fltFabricPinTargetDown
Fault Code: F1088
Message
Pin target is a non-existent interface
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricPinTargetDown
moClass: fabric:PinTarget
Affected MO: fabric/lan/lan-pin-group-[name]/target-[fabricId]
Affected MO: fabric/san/san-pin-group-[name]/target-[fabricId]
fltFabricExternalEpFcZoningEnable
Fault Code: F1089
Message
FC zoning is not supported from FI when connected to an uplink FC switch. Fabric: [switchId], Port: [slotId]/[portId].
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricExternalEpFcZoningEnable
moClass: fabric:ExternalEp
Affected MO: fabric/eth-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/fc-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/sanmon/[id]/fc-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/eth-target-[name]
fltFabricEthLanEpOverlapping-vlan
Fault Code: F1090
Message
On Fabric: [switchId], Port: [slotId]/[portId] following overlapping VLANs detected: [overlappingVlans]
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltFabricEthLanEpOverlappingVlan
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcOverlapping-vlan
Fault Code: F1091
Message
Overlapping VLANs detected on Fabric: [switchId], Port: [portId] in configured VLANs: [overlappingVlans]
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltFabricEthLanPcOverlappingVlan
Affected MO: fabric/lan/[id]/pc-[portId]
fltFabricFcEstcEpFc-storage-port-invalid
Fault Code: F1092
Message
FC storage port should not be created in NPV mode
Explanation
Recommended Action
Fault Details
Cause: fc-storageport-npv-mode
mibFaultName: fltFabricFcEstcEpFcStoragePortInvalid
Affected MO: fabric/fc-estc/[id]/phys-fc-slot-[slotId]-port-[portId]
fltFabricFcoeEstcEpFcoe-storage-port-invalid
Fault Code: F1093
Message
FCOE storage port should not be created in NPV mode
Explanation
Recommended Action
Fault Details
Cause: fcoe-storageport-npv-mode
mibFaultName: fltFabricFcoeEstcEpFcoeStoragePortInvalid
moClass: fabric:FcoeEstcEp
Affected MO: fabric/fc-estc/[id]/phys-fcoe-slot-[slotId]-port-[portId]
fltFabricFcSanPcFc-portchannel-members-invalid
Fault Code: F1094
Message
FC port channel member ports should have same max speed
Explanation
Recommended Action
Fault Details
Cause: fc-portchannel-members-inconsistent-speed
mibFaultName: fltFabricFcSanPcFcPortchannelMembersInvalid
Affected MO: fabric/san/[id]/pc-[portId]
fltFabricVlanMisconfigured-mcast-policy
Fault Code: F1095
Message
VLAN [name] multicast policy [mcastPolicyName] is non-default.
Explanation
Recommended Action
Fault Details
Cause: vlan-mcast-policy-misconfigured
mibFaultName: fltFabricVlanMisconfiguredMcastPolicy
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltMgmtConnectionDisabled
Fault Code: F1097
Message
Management Connection [type] in server [id] is not operational
Explanation
Recommended Action
Fault Details
Cause: another-connection-already-enabled
mibFaultName: fltMgmtConnectionDisabled
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltMgmtConnectionUnused
Fault Code: F1098
Message
Management Connection [type] in server [id] is unused
Explanation
Recommended Action
Fault Details
mibFaultName: fltMgmtConnectionUnused
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltMgmtConnectionUnsupportedConnectivity
Fault Code: F1099
Message
Unsupported connectivity for management connection [type] in server [id]
Explanation
Recommended Action
Fault Details
Cause: unsupported-connectivity
mibFaultName: fltMgmtConnectionUnsupportedConnectivity
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]
fltCallhomeEpNoSnmpPolicyForCallhome
Fault Code: F1102
Message
UCS Manager cannot apply Callhome policy if SNMP Policy is not configured or if SNMP Syscontact has an empty value. The Callhome policy from UCS Central has not been applied.
Explanation
Recommended Action
Fault Details
Cause: callhome-config-error
mibFaultName: fltCallhomeEpNoSnmpPolicyForCallhome
fltCapabilityCatalogueLoadErrors
Fault Code: F1103
Message
Load errors: File parse errors: [fileParseFailures], provider load failures: [providerLoadFailures], XML element load errors: [loadErrors].
Explanation
Recommended Action
Fault Details
Cause: load-catalog-failed
mibFaultName: fltCapabilityCatalogueLoadErrors
moClass: capability:Catalogue
Affected MO: capabilities
fltExtmgmtArpTargetsArpTargetsNotValid
Fault Code: F1114
Message
Invalid ARP Targets configured for Management Interface Polling. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
Cause: arp-targets-config-error
mibFaultName: fltExtmgmtArpTargetsArpTargetsNotValid
moClass: extmgmt:ArpTargets
Callhome Type: diagnostic
Affected MO: sys/extmgmt-intf-monitor-policy/arp-target-policy
fltVnicFcPinningMisconfig
Fault Code: F1209
Message
Hard pinning target for vHBA [name], service profile [name] is missing or misconfigured
Explanation
Recommended Action
Fault Details
mibFaultName: fltVnicFcPinningMisconfig
Affected MO: org-[name]/ls-[name]/fc-[name]
Affected MO: org-[name]/san-conn-pol-[name]/fc-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/fc-[name]
fltExtpolClientGracePeriodWarning
Fault Code: F1211
Message
UCS domain [name] registered with UCS Central has entered into the grace period.
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-entered
mibFaultName: fltExtpolClientGracePeriodWarning
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning2
Fault Code: F1212
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 10 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-10days
mibFaultName: fltExtpolClientGracePeriodWarning2
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning3
Fault Code: F1213
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 30 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-30days
mibFaultName: fltExtpolClientGracePeriodWarning3
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning4
Fault Code: F1214
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 60 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-60days
mibFaultName: fltExtpolClientGracePeriodWarning4
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning5
Fault Code: F1215
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 90 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-90days
mibFaultName: fltExtpolClientGracePeriodWarning5
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning6
Fault Code: F1216
Message
UCS Domain [name] registered with UCS Central is running in the grace period for more than 119 days
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-119days
mibFaultName: fltExtpolClientGracePeriodWarning6
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning7
Fault Code: F1217
Message
Grace period for UCS Domain [name] registered with UCS Central has expired. Please acquire a license for the same.
Explanation
Recommended Action
Fault Details
Cause: license-graceperiod-expired
mibFaultName: fltExtpolClientGracePeriodWarning7
Callhome Type: environmental
Affected MO: extpol/reg/clients/client-[id]
fltExtpolClientGracePeriodWarning1
Fault Code: F1218
Message
UCS Domain [name] is registered with UCS Central without a valid license.
Explanation
Recommended Action
Fault Details
Cause: license-insufficient
mibFaultName: fltExtpolClientGracePeriodWarning1
Affected MO: extpol/reg/clients/client-[id]
fltStorageItemFilesystemIssues
Fault Code: F1219
Message
Partition [name] on fabric interconnect [id] has file system errors
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageItemFilesystemIssues
Affected MO: sys/switch-[id]/stor-part-[name]
fltStorageInitiatorDuplicate-fc-zone
Fault Code: F1220
Message
Duplicate FC zones are created for initiator [name], because the same target wwpn [duplicateTarget] is duplicately configured in both boot and storage connection policy.
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltStorageInitiatorDuplicateFcZone
moClass: storage:Initiator
Affected MO: org-[name]/ls-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/ini-[name]
fltStorageIniGroupSwitch-mode-disabled
Fault Code: F1221
Message
FC zones cannot be deployed because FI is not running in FC switch mode.
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltStorageIniGroupSwitchModeDisabled
moClass: storage:IniGroup
Affected MO: org-[name]/ls-[name]/grp-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]
fltPkiKeyRingModulus
Fault Code: F1222
Message
[name] Keyring’s key modulus is invalid.
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: invalid-keyring-modulus
mibFaultName: fltPkiKeyRingModulus
Affected MO: sys/pki-ext/keyring-[name]
fltAaaOrgLocaleOrgNotPresent
Fault Code: F1223
Message
Locale Org [name] can’t be deployed. Error: [configStatusMessage]
Explanation
Recommended Action
Fault Details
Cause: locale-org-config-error
mibFaultName: fltAaaOrgLocaleOrgNotPresent
Affected MO: sys/user-ext/locale-[name]/org-[name]
fltNetworkOperLevelExtraprimaryvlans
Fault Code: F1229
Message
Fabric Interconnect [id]: Number of primary vlans exceeds the max limit on the FI: Number of Primary Vlans: [primaryVlanCount] and Max primary vlans allowed: [maxPrimaryVlanCount]
Explanation
Recommended Action
Fault Details
Cause: extra-primary-vlans
mibFaultName: fltNetworkOperLevelExtraprimaryvlans
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltEquipmentHealthLedCriticalError
Fault Code: F1236
Message
[dn] shows error. Reason [healthLedStateQualifier]
Explanation
Recommended Action
Fault Details
Cause: health-led-amber-blinking
mibFaultName: fltEquipmentHealthLedCriticalError
moClass: equipment:HealthLed
Callhome Type: environmental
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led
fltEquipmentHealthLedMinorError
Fault Code: F1237
Message
[dn] shows error. Reason: [healthLedStateQualifier]
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentHealthLedMinorError
moClass: equipment:HealthLed
Callhome Type: environmental
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led
fltVnicEtherIfRemoteVlanUnresolvable
Fault Code: F1249
Message
The named vlan [name] for vNIC [name] cannot be resolved remotely
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: referenced-remote-vlan-unresolvable
mibFaultName: fltVnicEtherIfRemoteVlanUnresolvable
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: fabric/lanmon/eth-flow-monitoring/flow-exporter-profile-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]
fltVnicFcIfRemoteVsanUnresolvable
Fault Code: F1250
Message
The named vsan [name] for vNIC [name] cannot be resolved remotely
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: referenced-remote-vsan-unresolvable
mibFaultName: fltVnicFcIfRemoteVsanUnresolvable
Affected MO: org-[name]/ls-[name]/fc-[name]/if-default
Affected MO: org-[name]/san-conn-pol-[name]/fc-[name]/if-default
Affected MO: org-[name]/san-conn-templ-[name]/if-default
Affected MO: org-[name]/tier-[name]/ls-[name]/fc-[name]/if-default
fltVnicEtherVirtualization-conflict
Fault Code: F1251
Message
Multiple connection policies cannot be assigned to the same Eth vNIC
Explanation
Recommended Action
Fault Details
Cause: multiple-connection-policies
mibFaultName: fltVnicEtherVirtualizationConflict
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltLsIssuesIscsi-config-failed
Fault Code: F1252
Message
Service Profile [name] configuration failed due to iSCSI issue [iscsiConfigIssues]
Explanation
Recommended Action
Fault Details
Cause: configuration-failed
mibFaultName: fltLsIssuesIscsiConfigFailed
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue
fltStorageLocalDiskMissing
Fault Code: F1256
Message
Local disk [id] missing on server [chassisId]/[slotId]Local disk [id] missing on server [id]Local disk [id] missing on chassis [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageLocalDiskMissing
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageFlexFlashControllerInoperable
Fault Code: F1257
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashControllerInoperable
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltStorageFlexFlashCardInoperable
Fault Code: F1258
Message
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]FlexFlash Card [slotNumber] on server [id] is inoperable. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashCardInoperable
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltStorageFlexFlashCardMissing
Fault Code: F1259
Message
FlexFlash Card [slotNumber] missing on server [chassisId]/[slotId]FlexFlash Card [slotNumber] missing on server [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageFlexFlashCardMissing
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltStorageFlexFlashVirtualDriveDegraded
Fault Code: F1260
Message
FlexFlash Virtual Drive RAID degraded on server [chassisId]/[slotId]. Reason: [raidState]FlexFlash Virtual Drive RAID degraded on server [id]. Reason: [raidState]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageFlexFlashVirtualDriveDegraded
moClass: storage:FlexFlashVirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]
fltStorageFlexFlashVirtualDriveInoperable
Fault Code: F1261
Message
FlexFlash Virtual Drive on server [chassisId]/[slotId] is inoperable. Reason: [raidState]FlexFlash Virtual Drive on server [id] is inoperable. Reason: [raidState]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageFlexFlashVirtualDriveInoperable
moClass: storage:FlexFlashVirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]
fltStorageFlexFlashControllerUnhealthy
Fault Code: F1262
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]
Explanation
Recommended Action
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashControllerUnhealthy
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltAaaProviderGroupProvidergroupsize
Fault Code: F1279
Message
For [dn]: Server Group [name] has [size] provider references. Authentication might fail, if this provider group is used with auth-domain.
Explanation
Recommended Action
Fault Details
Cause: provider-group-size-empty
mibFaultName: fltAaaProviderGroupProvidergroupsize
moClass: aaa:ProviderGroup
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]
fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
Fault Code: F1284
Message
Default host firmware package is missing or deleted.
Explanation
Recommended Action
Fault Details
Cause: default-hostpack-missing
mibFaultName: fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
moClass: firmware:AutoSyncPolicy
Affected MO: org-[name]/fw-auto-sync
fltFirmwareAutoSyncPolicyDefaultHostPackageMissingVersions
Fault Code: F1285
Message
B-series,C-series and M-series package versions are empty in default host firmware package
Explanation
Recommended Action
Fault Details
Cause: default-hostpack-missing-versions
mibFaultName: fltFirmwareAutoSyncPolicyDefaultHostPackageMissingVersions
moClass: firmware:AutoSyncPolicy
Affected MO: org-[name]/fw-auto-sync
fltFabricNetflowMonSessionFlowMonConfigFail
Fault Code: F1304
Message
Configuration for traffic flow monitor [name] failed, reason: [configFailReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricNetflowMonSessionFlowMonConfigFail
moClass: fabric:NetflowMonSession
Affected MO: fabric/lanmon/eth-flow-monitoring/netflow-mon-[name]
fltFabricNetflowMonSessionNetflowSessionConfigFail
Fault Code: F1305
Message
Netflow session configuration failed because [configQualifier]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltFabricNetflowMonSessionNetflowSessionConfigFail
moClass: fabric:NetflowMonSession
Affected MO: fabric/lanmon/eth-flow-monitoring/netflow-mon-[name]
fltFabricPooledVlanNamedVlanUnresolved
Fault Code: F1306
Message
VLAN [name] for VLAN group [name] cannot be resolved to any existing vlans.
Explanation
Recommended Action
Fault Details
Cause: named-vlan-unresolved
mibFaultName: fltFabricPooledVlanNamedVlanUnresolved
moClass: fabric:PooledVlan
Affected MO: fabric/lan/[id]/net-group-[name]/net-[name]
Affected MO: fabric/lan/net-group-[name]/net-[name]
fltExtvmmVMNDRefVmNetworkReferenceIncorrect
Fault Code: F1320
Message
VM Network [name] references [vmNetworkDefName] that is already being referenced by another VM Network
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: vm-network-reference-incorrect
mibFaultName: fltExtvmmVMNDRefVmNetworkReferenceIncorrect
Affected MO: fabric/lan/vm-network-sets/vm-network-[name]/vm-network-def-ref[name]
fltExtmgmtNdiscTargetsNdiscTargetsNotValid
Fault Code: F1321
Message
Invalid NDISC Targets configured for Management Interface Polling. Error: [configStatusMessage]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: ndisc-targets-config-error
mibFaultName: fltExtmgmtNdiscTargetsNdiscTargetsNotValid
moClass: extmgmt:NdiscTargets
Callhome Type: diagnostic
Affected MO: sys/extmgmt-intf-monitor-policy/ndisc-target-policy
fltFirmwareBootUnitPowerCycleRequired
Fault Code: F1325
Message
Board controller upgraded, manual a/c power cycle required on server [serverId]
Explanation
None set.
Recommended Action
Fault Details
Cause: board-ctrl-upgraded
mibFaultName: fltFirmwareBootUnitPowerCycleRequired
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltMgmtControllerUnsupportedDimmBlacklisting
Fault Code: F1328
Message
Dimm blacklisting is not supported on server [chassisId]/[slotId]Dimm blacklisting is not supported on server [id]
Explanation
Recommended Action
Fault Details
Cause: incompatible-server-firmware
mibFaultName: fltMgmtControllerUnsupportedDimmBlacklisting
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt
Affected MO: sys/chassis-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt
Affected MO: sys/chassis-[id]/mgmt
Affected MO: sys/chassis-[id]/shared-io-module/mgmt
Affected MO: sys/chassis-[id]/slot-[id]/mgmt
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt
Affected MO: sys/fex-[id]/mgmt
Affected MO: sys/fex-[id]/slot-[id]/mgmt
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt
Affected MO: sys/rack-unit-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt
Affected MO: sys/rack-unit-[id]/mgmt
Affected MO: sys/switch-[id]/mgmt
fltFabricEthLanEpUdldLinkDown
Fault Code: F1358
Message
UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricEthLanEpUdldLinkDown
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
fltFabricEthLanPcEpUdldLinkDown
Fault Code: F1359
Message
UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricEthLanPcEpUdldLinkDown
moClass: fabric:EthLanPcEp
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
fltFabricFcoeSanEpUdldLinkDown
Fault Code: F1360
Message
UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcoeSanEpUdldLinkDown
moClass: fabric:FcoeSanEp
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
fltFabricFcoeSanPcEpUdldLinkDown
Fault Code: F1361
Message
UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricFcoeSanPcEpUdldLinkDown
moClass: fabric:FcoeSanPcEp
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
fltFirmwareStatusCimcFirmwareMismatch
Fault Code: F1365
Message
Aggregate blade CIMC firmware mismatch. Firmware: [cimcVersion]
Explanation
Recommended Action
Fault Details
Cause: cimc-firmware-mismatch
mibFaultName: fltFirmwareStatusCimcFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fw-status
Affected MO: sys/chassis-[id]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status
fltFirmwareStatusPldFirmwareMismatch
Fault Code: F1366
Message
Aggregate blade board controller firmware mismatch. Firmware: [pldVersion]
Explanation
Recommended Action
Fault Details
Cause: pld-firmware-mismatch
mibFaultName: fltFirmwareStatusPldFirmwareMismatch
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fw-status
Affected MO: sys/chassis-[id]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status
fltSysdebugLogExportStatusLogExportFailure
Fault Code: F1369
Message
Log export to remote server failed from [switchId]:[exportFailureReason]
Explanation
Recommended Action
Fault Details
mibFaultName: fltSysdebugLogExportStatusLogExportFailure
moClass: sysdebug:LogExportStatus
Affected MO: sys/sysdebug/log-export-policy/log-export-status-[switchId]
fltVnicEtherVirtualization-netflow-conflict
Fault Code: F1380
Message
Netflow and VMQ/SRIOV-USNIC policies cannot be assigned to the same Eth vNIC
Explanation
Recommended Action
Fault Details
Cause: multiple-connection-policies
mibFaultName: fltVnicEtherVirtualizationNetflowConflict
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]
fltFabricVlanPrimaryVlanMissingForIsolated
Fault Code: F1382
Message
Primary Vlan can not be resolved for isolated vlan [name]
Explanation
Recommended Action
Fault Details
Cause: primary-vlan-missing-for-isolated
mibFaultName: fltFabricVlanPrimaryVlanMissingForIsolated
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanPrimaryVlanMissingForCommunity
Fault Code: F1383
Message
Primary Vlan can not be resolved for community vlan [name]
Explanation
Recommended Action
Fault Details
Cause: primary-vlan-missing-for-community
mibFaultName: fltFabricVlanPrimaryVlanMissingForCommunity
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanMismatch-a
Fault Code: F1384
Message
VLAN [name] has [overlapStateForA] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect A
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricVlanMismatchA
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanMismatch-b
Fault Code: F1385
Message
VLAN [name] has [overlapStateForB] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect B
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricVlanMismatchB
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltFabricVlanErrorAssocPrimary
Fault Code: F1386
Message
VLAN [name] is in error state because the associated primary vlan [assocPrimaryVlanState]
Explanation
Recommended Action
Fault Details
Cause: vlan-error-assoc-primary
mibFaultName: fltFabricVlanErrorAssocPrimary
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]
fltLsServerSvnicNotPresent
Fault Code: F1388
Message
Service profile [name] does not contain service vnics for netflow.
Explanation
Recommended Action
Fault Details
mibFaultName: fltLsServerSvnicNotPresent
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]
fltLsIssuesKvmPolicyUnsupported
Fault Code: F1389
Message
Kvm mgmt policy not supported by current CIMC version
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: unsupported-cimc-firmware
mibFaultName: fltLsIssuesKvmPolicyUnsupported
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue
fltMgmtBackupPolicyConfigConfiguration backup outdated
Fault Code: F1392
Message
Config backup may be outdated
Explanation
Recommended Action
Fault Details
Cause: config-backup-outdated
mibFaultName: fltMgmtBackupPolicyConfigConfigurationBackupOutdated
moClass: mgmt:BackupPolicyConfig
Affected MO: sys/bkup-policy-cfg
fltNetworkOperLevelExtrasecondaryvlans
Fault Code: F1396
Message
Fabric Interconnect [id]: Number of secondary vlans exceeds the max limit on the FI: Number of secondary vlans: [secondaryVlanCount] and Max secondary vlans allowed: [maxSecondaryVlanCount]
Explanation
Recommended Action
Fault Details
Cause: extra-secondary-vlans
mibFaultName: fltNetworkOperLevelExtrasecondaryvlans
moClass: network:OperLevel
Affected MO: sys/switch-[id]/oper-level
fltSwVlanExtrasecondaryvlansperprimary
Fault Code: F1397
Message
Number of secondary vlans associated with the primary vlan [id] in Fabric Interconnect [switchId] exceeds the max limit: Number of secondary vlans: [secVlanPerPrimaryVlanCount] and Max secondary vlans allowed in a primary vlan: 30
Explanation
Recommended Action
Fault Details
Cause: extra-secondary-vlans-per-primary
mibFaultName: fltSwVlanExtrasecondaryvlansperprimary
Affected MO: fabric/lan/profiles/vnic-[name]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/vnic-[name]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoeestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/vlan-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/flowexporter-netflow-[name]/vlan-[id]
Affected MO: sys/switch-[id]/ethlanflowmon/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/fcoesan-pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/sanmon-fc/mon-[name]/vc-[id]/vlan-[id]
fltCimcvmediaActualMountEntryVmediaMountFailed
Fault Code: F1404
Message
Server [chassisId]/[slotId] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.Server [id] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.Server [chassisId]/[slotId]/[serverInstanceId] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.
Explanation
None set.
Recommended Action
Fault Details
Cause: vmedia-mount-inaccessible
mibFaultName: fltCimcvmediaActualMountEntryVmediaMountFailed
moClass: cimcvmedia:ActualMountEntry
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/switch-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
fltEquipmentTpmSlaveTpm
Fault Code: F1439
Message
Server [chassisId]/[slotId], has a Tpm present on the Slave Board.
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: tpm-on-slave-board
mibFaultName: fltEquipmentTpmSlaveTpm
Affected MO: sys/chassis-[id]/blade-[slotId]/board/Tpm-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/Tpm-[id]
Affected MO: sys/rack-unit-[id]/board/Tpm-[id]
fltStorageMezzFlashLifeConfiguration-error
Fault Code: F1448
Message
Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]
Explanation
Recommended Action
Fault Details
Cause: configuration-error
mibFaultName: fltStorageMezzFlashLifeConfigurationError
moClass: storage:MezzFlashLife
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-
fltStorageMezzFlashLifeDegraded
Fault Code: F1449
Message
Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]
Explanation
Recommended Action
Fault Details
Cause: equipment-degraded
mibFaultName: fltStorageMezzFlashLifeDegraded
moClass: storage:MezzFlashLife
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/chassis-[id]/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-
fltStorageFlexFlashControllerMismatch
Fault Code: F1450
Message
FlexFlash Controller [id] on server [chassisId]/[slotId] has SD cards with different sizes.FlexFlash Controller [id] on server [id] has SD cards with different sizes.
Explanation
Recommended Action
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashControllerMismatch
moClass: storage:FlexFlashController
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]
fltStorageFlexFlashDriveUnhealthy
Fault Code: F1451
Message
FlexFlash Drive [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [operationState]FlexFlash Drive [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [operationState]
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashDriveUnhealthy
moClass: storage:FlexFlashDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
fltStorageFlexFlashCardUnhealthy
Fault Code: F1452
Message
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is unhealthy. Reason: [cardHealth]FlexFlash Card [slotNumber] on server [id] is unhealthy. Reason: [cardHealth]
Explanation
Recommended Action
Fault Details
Cause: equipment-unhealthy
mibFaultName: fltStorageFlexFlashCardUnhealthy
moClass: storage:FlexFlashCard
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]
fltPoolElementDuplicatedAssigned
Fault Code: F1453
Message
ID is duplicated assigned for multiple servers(Check UCSC for details)
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
Cause: duplicated-assigned
mibFaultName: fltPoolElementDuplicatedAssigned
fltMgmtInterfaceNamedInbandVlanUnresolved
Fault Code: F1454
Message
[configMessage]
Explanation
Recommended Action
Fault Details
Cause: named-inband-vlan-unresolved
mibFaultName: fltMgmtInterfaceNamedInbandVlanUnresolved
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltMgmtInterfaceInbandUnsupportedServer
Fault Code: F1455
Message
[configMessage]
Explanation
Recommended Action
Fault Details
Cause: inband-unsupported-server
mibFaultName: fltMgmtInterfaceInbandUnsupportedServer
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltMgmtInterfaceInbandUnsupportedFirmware
Fault Code: F1456
Message
[configMessage]
Explanation
Recommended Action
Fault Details
Cause: unsupported-cimc-firmware
mibFaultName: fltMgmtInterfaceInbandUnsupportedFirmware
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]
fltSwVlanPortNsResourceStatusWarning
Fault Code: F1464
Message
Total Available Vlan-Port Count on switch [switchId] is below 10%
Explanation
None set.
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltSwVlanPortNsResourceStatusWarning
Callhome Type: diagnostic
Affected MO: sys/switch-[id]/vlan-port-ns
fltNetworkElementMemoryerror
Fault Code: F1465
Message
Fabric Interconnect [id] memory less than expected! Total Memory: [totalMemory] and Expected Memory: [expectedMemory]
Explanation
Recommended Action
Fault Details
mibFaultName: fltNetworkElementMemoryerror
Callhome Type: diagnostic
Affected MO: sys/switch-[id]
fltComputePhysicalAdapterMismatch
Fault Code: F1467
Message
Server [id] (service profile: [assignedToDn]) has invalid adapter combinatonServer [chassisId]/[slotId] (service profile: [assignedToDn]) has invalid adapter combination
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputePhysicalAdapterMismatch
moClass: compute:Physical
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]
Affected MO: sys/rack-unit-[id]
fltStorageLocalDiskThermalIssueCritical
Fault Code: F1604
Message
Local disk [id] on server [chassisId]/[slotId] has thermal issue: [thermal]Local disk [id] on server [id] has thermal issue: [thermal]Local disk [id] on chassis [id] has thermal issue: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageLocalDiskThermalIssueCritical
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageLocalDiskThermalIssueNonRecoverable
Fault Code: F1605
Message
Local disk [id] on server [chassisId]/[slotId] has thermal issue: [thermal]Local disk [id] on server [id] has thermal issue: [thermal]Local disk [id] on chassis [id] has thermal issue: [thermal]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageLocalDiskThermalIssueNonRecoverable
moClass: storage:LocalDisk
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltStorageLocalDiskNot-supported
Fault Code: F1606
Message
Local disk [id] is not supported on server [chassisId]/[slotId]Local disk [id] is not supported on server [id]Local disk [id] is not supported on chassis [id]
Explanation
Recommended Action
Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.
Fault Details
mibFaultName: fltStorageLocalDiskNotSupported
moClass: storage:LocalDisk
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]
fltFabricComputeMSlotEpMisplacedInChassisSlot
Fault Code: F1616
Message
Server, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId]/[serverInstanceId] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricComputeMSlotEpMisplacedInChassisSlot
moClass: fabric:ComputeMSlotEp
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]/ins-[serverInstanceId]
fltFabricComputeMSlotEpServerIdentificationProblem
Fault Code: F1617
Message
Problem identifying server [serverInstanceId] in slot [chassisId]/[slotId]
Explanation
Recommended Action
Fault Details
Cause: server-identification-problem
mibFaultName: fltFabricComputeMSlotEpServerIdentificationProblem
moClass: fabric:ComputeMSlotEp
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]/ins-[serverInstanceId]
fltFabricCartridgeSlotEpMisplacedInChassisSlot
Fault Code: F1618
Message
Cartridge, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId] presence: [presence]
Explanation
Recommended Action
Fault Details
mibFaultName: fltFabricCartridgeSlotEpMisplacedInChassisSlot
moClass: fabric:CartridgeSlotEp
Affected MO: fabric/server/chassis-[chassisId]/cart-slot-[slotId]
fltStorageControllerNot-supported
Fault Code: F1620
Message
Controller [id] is not supported on chassis [id]
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageControllerNotSupported
moClass: storage:Controller
Callhome Type: diagnostic
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]
fltStorageVirtualDriveDeployment-failure
Fault Code: F1621
Message
Virtual drive [name] deployment failure. Reason: [configQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: equipment-inoperable
mibFaultName: fltStorageVirtualDriveDeploymentFailure
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveMissing
Fault Code: F1622
Message
Virtual drive [name] missing
Explanation
Recommended Action
Fault Details
mibFaultName: fltStorageVirtualDriveMissing
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVirtualDriveMismatch
Fault Code: F1623
Message
Virtual drive [name] mismatch. Reason: [configQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: configuration-mismatch
mibFaultName: fltStorageVirtualDriveMismatch
moClass: storage:VirtualDrive
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]
fltStorageVDMemberEpMismatch
Fault Code: F1624
Message
Virtual drive member [id] in a mismatched state. Reason: [operQualifierReason]
Explanation
Recommended Action
Fault Details
Cause: configuration-mismatch
mibFaultName: fltStorageVDMemberEpMismatch
moClass: storage:VDMemberEp
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/vd-[id]/member-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]/member-[id]
fltFirmwareBootUnitFirmwareBootFailed
Fault Code: F1627
Message
Endpoint firmware went faulty.
Explanation
Recommended Action
Fault Details
mibFaultName: fltFirmwareBootUnitFirmwareBootFailed
moClass: firmware:BootUnit
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/cartridge-[slotId]/server-[serverInstanceId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/shared-io-module/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]
fltEquipmentChassisMajorError
Fault Code: F1634
Message
Chassis [model] is not supported in this version of UCS Manager
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentChassisMajorError
moClass: equipment:Chassis
Affected MO: sys/chassis-[id]
fltEquipmentFexMajorError
Fault Code: F1635
Message
Fex [model] is not supported in this version of UCS Manager
Explanation
Recommended Action
Fault Details
mibFaultName: fltEquipmentFexMajorError
Affected MO: sys/fex-[id]
fltComputeRackUnitMajorError
Fault Code: F1654
Message
Server [model] is not supported in this version of UCS Manager
Explanation
Recommended Action
Fault Details
mibFaultName: fltComputeRackUnitMajorError
moClass: compute:RackUnit
Affected MO: sys/rack-unit-[id]