Cisco UCS C-Series and S-Series Servers
Cisco UCS C-Series and S-Series Servers deliver unified computing in an industry-standard form factor to reduce total cost of ownership and increase agility. Each product addresses varying workload challenges through a balance of processing, memory, I/O, and internal storage resources.
About the Release Notes
This document describes the new features, system requirements, open caveats and known behaviors for C-Series and S-Series software release 3.0(3) including Cisco Integrated Management Controller software and any related BIOS, firmware, or drivers. Use this document in conjunction with the documents listed in the Related Documentation section.
![]() Note |
We sometimes update the documentation after original publication. Therefore, you should also refer to the documentation on Cisco.com for any updates. |
Support for Web UI Interface on Cisco UCS M3 Rack Server Software Post Flash Deprecation
The Cisco Cloud and Compute organization at Cisco expects that the Web UI interface of UCS M3 Standalone Rack Server Software – Cisco IMC – will not be accessible on future versions of web browsers that are going to deprecate support for Flash Player based content.
Cisco started shipping UCS C-Series and S-Series M3 Servers in 2012 and announced in 2015 and 2016 the EOL of all M3 rack server models, before Adobe announced the EOL of Flash Player support in July 2017. While we will continue to provide applicable service and support such as critical security fixes via patch releases for M3 servers through the End of Support date in December 2021, we do not plan to retrofit UCS C-Series and S-Series M3 platforms with HTML5-based Web UI interface for Cisco IMC.
Impacted customers can consider below alternatives for managing their M3 Rack Servers:
-
Use CLI interface of IMC Software to control and configure the standalone M3 rack platforms
-
Use a web browser that will not be deprecating support for Flash
-
Keep web browser on the last version that supports Flash and disable update to future version in order to continue using Web UI to manage M3 rack servers
-
Attach the M3 rack servers to Fabric Interconnects in order to use HTML5-based Web UI interface of a corresponding UCS Manager release
-
Access vKVM through the XML API in case Web UI is not available
Revision History
Revision |
Date |
Description |
---|---|---|
H0 |
September 25, 2020 |
Added notice: Support for Web UI Interface on Cisco UCS M3 Rack Server Software Post Flash Deprecation |
G0 |
November 29, 2017 |
Following changes were made:
|
F0 |
October 16, 2017 |
Following changes were made:
|
E0 |
September 28, 2017 |
Following changes were made:
|
D0 |
September 5, 2017 |
Added a note about a downgrade scenario to the Updating the Firmware section. |
C0 |
July 24, 2017 |
Following changes were made:
|
B0 |
June 29, 2017 |
Following changes were made:
|
A0 |
April 27, 2017 |
Created release notes for Release 3.0(3a). |
Supported Platforms and Release Compatibility Matrix
Overview of the Supported Servers
The following servers are supported in Release 3.0(3c):
-
UCS-C240 M4
-
UCS-C220 M4
The following servers are supported in Release 3.0(3b):
-
UCS-S3260 M3
-
UCS-C3160 M3
-
UCS-C460 M4
-
UCS-C240 M4
-
UCS-C220 M4
The following servers are supported in Release 3.0(3a):
-
UCS-S3260 M4
-
UCS-S3260 M3
-
UCS-C3160 M3
-
UCS-C460 M4
-
UCS-C240 M4
-
UCS-C220 M4
-
UCS-C220 M3
-
UCS-C240 M3
-
UCS-C22 M3
-
UCS-C24 M3
For information about these servers, see Overview of Servers
Cisco IMC and Cisco UCS Manager Release Compatibility Matrix
Cisco UCS C-Series and S-Series Rack-Mount Servers are managed by built-in standalone software—Cisco IMC. However, when a Rack-Mount Server is integrated with Cisco UCS Manager, the Cisco IMC does not manage the server anymore.
The following table lists the supported platforms, Cisco IMC releases, and Cisco UCS Manager releases for Rack-Mount Servers:
Cisco IMC Release |
Cisco UCS Manager Release |
Rack-Mount Servers |
---|---|---|
3.0(3f) |
- |
Cisco UCS C240 M4, and C220 M4 |
3.0(3e) |
3.0(3e) |
Cisco UCS C22 M3, C24 M3, C220 M3, C240 M3, C220 M4, C240 M4, C460 M4, C3160 M3, S3260 M4 and S3260 M3 servers |
3.0(3c) |
3.0(3c) |
Cisco UCS C240 M4, and C220 M4 |
3.0(3b) |
3.0(3b) |
Cisco UCS S3260 M3, C3160 M3, C460 M4, C240 M4, and C220 M4 |
3.0(3a) |
3.1(3a) |
Cisco UCS C22 M3, C24 M3, C220 M3, C240 M3, C220 M4, C240 M4, C460 M4, C3160 M3, S3260 M4 and S3260 M3 servers |
Cisco IMC Release |
Cisco UCS Manager Release |
Rack-Mount Servers |
||
---|---|---|---|---|
3.0(2b) |
No Support
|
C220 M4/C240 M4 only |
Cisco IMC Release |
Cisco UCS Manager Release |
Rack-Mount Servers |
||
---|---|---|---|---|
3.0(1d) |
No Support
|
All M3/M4 except C420 M3 |
||
3.0(1c) |
No Support |
All M3/M4 except C420 M3 |
Cisco IMC Release |
UCS Manager Release |
Rack Mount Servers |
---|---|---|
2.0(13e) |
3.1(2b) |
All M3/M4 except C420 M3 |
2.0(10b) |
3.1(1g) |
C220 M4/C240 M4 only |
2.0(9c) |
3.1(1e) |
All other M3/M4 |
2.0(9f) |
2.2(7b) |
For all other M3/M4 |
2.0(10b) |
2.2(7b) |
C220 M4/C240 M4 only |
1.5(9d) |
2.2(7b) |
C420-M3, C260-M2, C460-M2 only |
1.5(9d) |
2.2(8f) |
C420-M3, C260-M2, C460-M2 only |
2.0(9c) |
2.2(8f) |
For all other M3/M4 |
2.0(10b) |
2.2(8f) |
C220 M4/C240 M4 only |
2.0(12b) |
2.2(8f) |
C460 M4 only |
1.5(8a) |
2.2(6g) |
C420 M3, C260 M2, C460 M2 only |
2.0(8d) |
2.2(6c) |
For all other M3/M4 |
1.5(7f) |
2.2(5b) |
C420 M3, C260 M2, C460 M2 only |
2.0(6d) |
2.2(5a) |
For all other M3/M4 |
1.5(7a)2 |
2.2(4b) |
C420 M3, C260 M2, C460 M2 only |
2.0(4c) |
2.2(4b) |
For all other M3/M4 |
1.5(7c)1 |
2.2(3b) |
C420 M3, C260 M2, C460 M2 only |
2.0(3d)1 |
2.2(3a) |
For all other M3/M4 |
System Requirements
The management client must meet or exceed the following minimum system requirements:
-
Sun JRE 1.8.0_92 or later (Till 1.8.0_121)
-
HTML based interfaces are supported on:
-
Microsoft Internet Explorer 10.0 or 11
-
Mozilla Firefox 30 or higher
-
Google Chrome 38 or higher
-
Safari 7 or higher
Note
If the management client is launched using an unsupported browser, check the help information from the For best results use supported browsers option available in the login window for the supported browser versions.
-
-
For Classic View - all browsers must have Adobe Flash Player 11 plug-in or higher. Supported browsers are:
-
Microsoft Internet Explorer 11 or higher
-
Mozilla Firefox 54 or higher
-
Google Chrome 61 or higher
-
Safari 11 or higher
-
-
Microsoft Windows 7, Microsoft Windows XP, Microsoft Windows Vista, Microsoft Windows 10, Apple Mac OS X v10.6, Red Hat Enterprise Linux 5.0 or higher operating systems
-
Transport Layer Security (TLS) version 1.2.
Hardware and Software Interoperability
For detailed information about storage switch, operating system and adapter, see the Hardware and Software Interoperability Matrix for your release located at:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
![]() Note |
Connectivity is tested between the server and the first connected device. Further connections, such as to storage arrays after a switch are not listed in the Cisco UCS Hardware Compatibility List though they may be highlighted in the vendor support matrix for those devices. |
For details about transceivers and cables that are supported on VIC cards, see the Transceiver Modules Compatibility Matrix
You can also see the VIC data sheets for more compatibility information: Cisco UCS Virtual Interface Card Data Sheets
Upgrade Paths for Release 3.0
The section provides information on the upgrade paths for release 3.0. Refer to the table for upgrade paths for various Cisco UCS C-series IMC versions.
Upgrade From Release |
Upgrade To Release |
Recommended Upgrade Path |
---|---|---|
Incase of C460 M4 for release lesser than 2.0(4c) |
3.0 |
Follow these steps to upgrade from releases less than 2.0(4c) to 3.0: Upgrade from version less than 2.0(4c) to 2.0(4c)
Upgrade from 2.0(4c) to 3.0
|
Incase of C460 M4 for releases greater than 2.0(4c) All other M4 servers from 2.0 |
3.0 |
Follow below upgrade path:
|
For C220 M4 and C240 M4 from 2.0 |
3.0(4a) and 3.0(4d) |
Follow below upgrade path:
|
For M3 servers from 1.4 and releases lesser than 1.5(4) |
3.0 |
Before update, Reboot the bmc. Upgrade from 1.4 to 1.5(4)
Upgrade from 1.5(4) to 2.0(4c)
Upgrade from 2.0(4c) to 3.0
|
For all M3 servers for releases after 1.5(4) |
3.0 |
Upgrade from 1.5 to 2.0(4c)
Upgrade from 2.0(4c) to 3.0
|
Transceivers Specifications
The Cisco UCS C-Series servers supports a wide variety of 10 Gigabit Ethernet connectivity options using Cisco 10GBASE SFP+ modules.
Controllers (LOM and PCIe) | 10GBASE-CU SFP+ Cable 1 Meter, passive | 10GBASE-CU SFP+ Cable 3 Meter, passive | |
SFP-H10GB-CU1M | SFP-H10GB-CU3M | ||
Cisco UCS Virtual Interface Cards | x | x | |
Intel x520 | |||
Broadcom 57712 | x | x | |
Controllers (LOM and PCIe) | 10GBASE-CU SFP+ Cable 5 Meter, passive | 10GBASE-CU SFP+ Cable 7 Meter, active | 10GBASE-CU SFP+ Cable 10 Meter, active |
SFP-H10GB-CU5M | SFP-H10GB-ACU7M | SFP-H10GB-ACU10M | |
Cisco UCS Virtual Interface Cards | x | x | x |
Intel x520 | |||
Broadcom 57712 | x | x | x |
Controllers (LOM and PCIe) | Intel SR Optics | JDSU (PLRXPL-SC-S43-22-N) SFP+ | Cisco SFP-10G-SR |
Cisco UCS Virtual Interface Cards | NA | NA | x |
Intel x520 | x | NA | NA |
Broadcom 57712 | NA | x | x |
Firmware Upgrade Details
Firmware Files
The C-Series software release 3.0(3) includes the following software files:
CCO Software Type | File name(s) | Comment |
Unified Computing System (UCS) Server Firmware |
ucs-s3260-huu-3.0.3.iso ucs-c3160-huu-3.0.3.iso ucs-c240m4-huu-3.0.3.iso ucs-c220m4-huu-3.0.3.iso ucs-c460m4-huu-3.0.3.iso ucs-c220-huu-3.0.3.iso ucs-c240-huu-3.0.3.iso ucs-c2x-huu-3.0.3.iso For release specific ISO versions, see Cisco UCS C-Series Integrated Management Controller Firmware Files, Release 3.0 |
Host Upgrade Utility |
Unified Computing System (UCS) Drivers | ucs-cxxx-drivers.3.0.3.iso | Drivers |
Unified Computing System (UCS) Utilities |
ucs-cxxx-utils-efi.3.0.3.iso ucs-cxxx-utils-linux.3.0.3.iso ucs-cxxx-utils-vmware.3.0.3.iso ucs-cxxx-utils-windows.3.0.3.iso |
Utilities |
![]() Note |
Always upgrade the BIOS, the Cisco IMC and CMC from the HUU ISO. Do not upgrade individual components (only BIOS or only Cisco IMC or CMC), since this could lead to unexpected behavior. If you choose to upgrade BIOS, the Cisco IMC and the CMC individually and not from the HUU ISO, make sure to upgrade both Cisco IMC, BIOS and CMC to the same container release. If the BIOS, CMC and the Cisco IMC versions are from different container releases, it could result in unexpected behavior. Cisco recommends that you use the Update All option from the Host Upgrade Utility to update the firmware versions of Cisco IMC, BIOS, CMC and all other server components (VIC, RAID Controllers, PCI devices, and LOM) together. |
Host Upgrade Utility
The Cisco Host Upgrade Utility (HUU) is a tool that upgrades the Cisco UCS C-Series firmware.
The image file for the firmware is embedded in the ISO. The utility displays a menu that allows you to choose which firmware components to upgrade. For more information on this utility see:
http://www.cisco.com/en/US/products/ps10493/products_user_guide_list.html
For details of firmware files in Cisco Host Upgrade Utility for individual releases, see Cisco UCS C-Series Integrated Management Controller Firmware Files, Release 3.1
Updating the Firmware
Use the Host Upgrade Utility to upgrade the C-Series firmware. Host Upgrade Utility can upgrade the following software components:
-
BIOS
-
Cisco IMC
-
CMC
-
SIOC
-
Cisco VIC Adapters
-
LSI Adapters
-
LAN on Motherboard Settings
-
PCIe adapter firmware
-
HDD firmware
-
SAS Expander firmware
All firmware should be upgraded together to ensure proper operation of your server.
![]() Note |
|
For more information on how to upgrade the firmware using the utility, see:
Supported Features
Supported Software Features
The following new software features are supported in Release 3.0(3):
-
Email Alerts using SMTP—Cisco IMC supports email-based notification of server faults to recipients without relying on the SNMP. The system uses the Simple Mail Transfer Protocol (SMTP) to send server faults as email alerts to the configured SMTP server. A maximum of four recipients is supported. This feature is available on all servers except C220 M3, C240 M3, C22 M3 and C24 M3 servers.
-
Reset to factory defaults—You can now choose to reset specific components such as Cisco IMC, storage, and VIC to factory defaults. This feature is available on all servers except C220 M3, C240 M3, C22 M3 and C24 M3 servers.
-
6G or 12G Mixed Mode on a SAS Expander—You can enable or disable a 6 gigabyte or 12 gigabyte mixed mode speed support for a card. This feature is available only on S3260 M4 and C3160 M3 servers.
-
Single Server Dual Connectivity—S3260 storage server supports a single server with dual connectivity. This features allows you to configure a new single server dual VIC chassis property on the Cisco IMC by enabling it or disabling it using the web UI or command line interface.
-
Key Management Interoperability Protocol (KMIP)—KMIP is a communication protocol that defines message formats to handle keys or classified data on a key management server. KMIP is an open standard and is supported by several vendors. Effective this release, KMIP feature is supported on the S3260 M4 servers.
-
Self Encrypting Drives (SED)—SED comprises special hardware in the drives that encrypts incoming data and decrypts outgoing data in real-time. This feature is also called Full Disk Encryption (FDE). Effective this release, SED feature is supported on the S3260 M4 servers.
-
Storage Enhancements—Clearing and resetting controller configuration actions are added. This feature is available on all servers except C220 M3, C240 M3, C22 M3 and C24 M3 servers.
-
Option ROM Status—Added Option ROM status for PCI adapters.
-
Added support for the following BIOS features:
-
Chassis asset tag— Set server asset tag in BIOS which can be read from the operating system level. This feature is available only on M4 servers.
-
Description field—Setting of a server description through the Cisco IMC, which can be read through the SMBIOS to identify the platform type. This feature is available only on M4 servers.
-
PXE support with VLAN configuration.
-
-
NVMe and RAID Controller support on IO Expander— S3260 M4 servers support NVMe and storage RAID controllers on IOE. This support was available on server nodes in the previous releases; which is now extended to IOE as well.
-
LED Blink Pattern— Ability to identify failed components based on the Fault-LED blink pattern.
Supported Hardware
New Hardware in Release 3.0(3e)
Support for the following new hardware is added in Release 3.0(3e) for the C220 M4, and C240 M4 servers:
-
Cisco 2.5" U.2 800GB HGST SN200 NVMe
-
Cisco 2.5" U.2 1.6TB HGST SN200 NVMe
-
Cisco HHHL AIC 3.2TB HGST SN250 NVMe
-
Cisco HHHL AIC 6.4TB HGST SN250 NVMe
-
Cisco HHHL AIC 7.7TB HGST SN250 NVMe
-
Intel X710-T4 (UCSC-PCIE-IQ10GC)
-
QLogic QL41212H 25GbE (UCSC-PCIE-QD25GF)
-
QLogic QL45212H 40GbE (UCSC-PCIE-QD40GF)
New Hardware in Release 3.0(3a)
The following new hardware is supported in Release 3.0(3a):
-
Intel® X550 adapter
-
NVIDIA M10 Support
-
QLogic QLE2742 dual-port 32G FC
-
Emulex LPe32002 dual-port 32G FC
-
Emulex LPe32000 single-port 32G FC
-
UCS AMD FirePro 7150X2 16GB GPU
-
NVIDIA P100 GPU (16GB, 12GB)
-
UCS S3260 Double Rock Pass through Controller
-
UCS C3000 RAID controller for M4 Servers
Software Utilities
The following standard utilities are available:
-
Host Update Utility (HUU)
-
BIOS and Cisco IMC Firmware Update utilities
-
Server Configuration Utility (SCU)
-
Server Diagnostic Utility (SDU)
The utilities features are as follows:
-
Availability of HUU, SCU on the USB as bootable images. The USB also contains driver ISO, and can be accessed from the host operating system.
SNMP
The supported MIB definition for this release and later releases can be found at the following link:
ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-C-supportlist.html
![]() Note |
The above link is incompatible with IE 9.0. |
Security Fixes
The following Security Fixes were added in Release 3.0(3e):
Release |
Defect ID |
CVE |
Symptom |
---|---|---|---|
3.0(3e) |
CSCvf46099 |
CVE-2016-2183 |
A vulnerability in Cisco Integrated Management Controller (Cisco IMC) version of the DES and triple DES ciphers was addressed. SSL Medium Strength Cipher Suites Supported and SSL 64-bit Block Size Cipher Suites Supported (SWEET32) vulnerabilities were addressed. |
Resolved Caveats
The following section lists resolved caveats.
Resolved Caveats in Release 3.0(3f)
The following defects are resolved in release 3.0(3f):
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvg13628 |
The UCS Java
KVM client experiences the following issues when used with Oracle Java version
9:
|
3.0(3e) |
3.0(3f) |
CSCvg03986 |
Disks on the HyperFlex server are locked after upgrading the C-bundle. This happens when upgrading UCS Manager from 3.1(3c) to 3.2(1d). |
3.0(3e) |
3.0(3f) |
CSCvg13277 |
Cisco IMC syslog timestamp field stops being RFC3164 compliant after upgrading from any 2.0 version to 3.0 version. |
3.0(3c) |
3.0(3f) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvc69549 |
When Patrol Read clear frequency is set incorrectly, you may see the following error messages intermittently: Controller 1 on server 2 is inoperable. Reason: Device reported corrupt data Line 27142: 2016 Dec 19 21:00:48 UCS-FFM-106-B %UCSM-2-EQUIPMENT_INOPERABLE: [F1004][cleared] [equipment-inoperable] [sys/rack-unit-2/board/storage-SAS-1] Controller 1 on server 2 is inoperable. Reason: Device reported corrupt data |
3.0(3c) |
3.0(3f) |
CSCve95795 |
RAID errors seen indication RAID as in degraded state. Error recommends to replace or reseat the RAID controller. Issue persists even after replacing or reseating the controller. |
2.0(13f) |
3.0(3f) |
Resolved Caveats in Release 3.0(3e)
The following defect is resolved in release 3.0(3e):
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCve86161 |
After upgrading the firmware to version 3.0(3a) on the C220 M3 servers, when you enter the login credentials at the login screen of the Cisco IMC web UI, an attempting to authenticate message is displayed but does not log in. After a while you get an incorrect information message. |
3.0(3a) |
3.0(3e) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvf78458 |
System becomes unresponsive or may reboot during OS operation with PROCHOT, MEMHOT, and DMI Timeout related events reported in the System Event Log (SEL). This fix changes the BIOS option Package C-State limit default value from C6 Retention to C0/C1 to help increase system stability and eliminate system crash scenarios. |
3.0(3a) |
3.0(3e) |
CSCvd86049 |
System becomes unresponsive or may reboot during OS operation with PROCHOT, MEMHOT, and DMI Timeout related events reported in the System Event Log (SEL). This fix changes the default BIOS option for ASPM (Active State Power Management) from L1 only to Disabled, and the ASPM setting can no longer be modified. |
3.0(3a) |
3.0(3e) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvb89363 |
The clear boot drive operation fails on the LSI MegaRAID SAS 9266-8i controllers. |
3.0(3a) |
3.0(3e) |
CSCvd54828 |
The LSI 9271-8i MegaRAID SAS HBA controller encounters a fatal error and resets. This happens when you use the SATA SSD. |
3.0(3a) |
3.0(3e) |
Resolved Caveats in Release 3.0(3c)
The following defects are resolved in release 3.0(3c):
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvf03853 |
Bind password is visible in the /var/LDAP_Configuration_Info.txt file that is available in the tech support bundle. This happens when you generate tech support data after the LDAP is configured for version 3.0(3), and the bind password is set. |
3.0(3a) |
3.0(3c) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvd78194 |
cucsStorageRaidBatteryOperability indicates that the BBU or Supercap is operable even when the BBU or Supercap related faults are displayed on Cisco IMC. This may occur when BBU or Supercap is inserted in a degraded state. |
2.0(13e) |
3.0(3c) |
CSCvf17810 |
Critical fault F0883 is visible on the Cisco IMC web UI faults page but is not visible in the SNMP cucsFaultTable when a PSU loses input power: 'Critical F0883 power-problem PSU2_PWRGD: Power supply 2 is in a degraded state, or has bad input voltage: Check Power Supply status' |
3.0(3a) |
3.0(3c) |
Resolved Caveats in Release 3.0(3b)
The following defects are resolved in release 3.0(3b):
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCve42450 |
Updating the TLS Cipher firmware used by the C-Series server to version 3.0(3a) enables a weak TLS Cipher that resulted in the server becoming vulnerable to a logjam attack. |
3.0(3a) |
3.0(3b) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCve32835 |
After creating a login banner, the format of the banner content displayed on the web interface is incorrect. |
3.0(3a) |
3.0(3b) |
Resolved Caveats in Release 3.0(3a)
The following defects are resolved in release 3.0(3a):
Defect ID |
Symptom |
First Affected Release |
Resolved in Release |
CSCvb88997 |
Occasionally, on some C220 M4 and C240 M4 servers, when you upgrade BIOS firmware from an older version to release 2.0(13), some power capping features become unavailable and management engine (ME) SEL event may get logged. |
2.0(13e) |
3.0(3a) |
CSCvc06842 |
On the C220 M4 and C240 M4 servers, processor configuration error occurs when the Broadcom 5709 adapter is present. The VMware ESXi OS remains unresponsive while disconnecting the virtual machine, and triggering SEL events such as PROCHOT(processor hot) and MEMHOT(memory hot). |
2.0(10e) |
3.0(3a) |
CSCva96780 | A server with multiple adapters may fail to boot and appears in the BIOS setup menu. This happens on the first boot up after the placement policy is changed (when the vNIC placement policy is changed between the adapters). | 2.0(13e) | 3.0(3a) |
CSCux47767 | The C220
M4 and C240 M4 servers might become unresponsive during BIOS posting while
configuring the platform hardware.
This happens when one of the PCIe devices stops responding due to Option ROM shadowing. |
2.0(13e) | 3.0(3a) |
CSCup51154 | The HII interface for 9300 is blank when 9300 external LSI adapter is present and ROM mode option is enabled. | 2.0(3d) | 3.0(3a) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvc86588 |
Cisco IMC reports an empty storage controller PCI inventory. This happens due to a communication issue between the controller and Cisco IMC. |
3.0(1c) |
3.0(3a) |
CSCvd20645 |
After upgrading Cisco IMC from release 2.0(13e) to 3.0(1e), the web GUI becomes inaccessible. However, you can ping the Cisco IMC IP address from Secure Shell. |
3.0(1c) |
3.0(3a) |
CSCvd07907 |
On the M4 servers, when
creating a vNIC using HTML5 web UI with a Non-English browser language, the
following error is displayed:
"Validation failed for property coalescing-type:Valid values are [MIN | IDLE]" |
3.0(2b) | 3.0(3a) |
CSCuz61163 | After upgrading the server firmware to 2.0(13e), the P1_THERMTRIP & P2_THERMTRIP sensors assertion critical events and deassertion events might be seen in the System Event Log. These are events are not valid and can be ignored. | 2.0(13e) | 3.0(3a) |
CSCul95481 | The DIMM temperature sensors are not displayed in the Web UI or CLI interfaces. | 2.0(4c) | 3.0(3a) |
CSCvb12936 | On the C460 M4 server, after an HUU firmware update, an NVME drive may not be found in the out-of-band storage configuration. | 2.0(13e) | 3.0(3a) |
CSCuz15634 | When the C460 M4 servers are used in a 2-CPU configuration, any NVMe drive FrontPCIe9 slot is not visible. | 2.0(13e) | 3.0(3a) |
CSCuc83809 |
Repeated VIC adapter resets using Cisco IMC Web UI or CLI adapter-reset can cause VIC card to hang. |
1.4(7) |
3.0(3a) |
CSCvc86706 | In a particular scenario, when you upgrade the firmware from a 1.5(x) version to 3.0(1c) or 2.0(x), downgrade back to 1.5(x) and then upgrade to 3.0(1c) again, Cisco IMC user database is corrupted and all the user IDs are displayed as (-1) in the Web UI and CLI. |
3.0(1c) |
3.0(3a) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvb24327 | On the 3260 servers, when more than 20 drives are zoned to a server while the server is online, it takes a long time (a maximum of 7 minutes) for the drives to be discovered and displayed. | 2.0(13e) | 3.0(3a) |
CSCva61275 | On
activating the firmware on SSDs, the following critical error is displayed:
Controller X on server X is inoperable. Reason: CIMC didn't detect storage controller This happens
when you activate the following following models of HGST NVMe SSDs:
This issue occurs because the active slot firmware on the NVMe SSD reverts to the firmware present on the read-only slot. If the firmware on the read only slot does not support Out-Of-Band, this NVMe is not reported in the Out-Of-Band inventory stage with the following message: "Controller X on server X is inoperable. Reason: CIMC didn't detect storage controller". |
2.0(13e) | 3.0(3a) |
CSCva80462 | The Intel X710 adapter MAC address is displayed as "000000000000". This happens when the system has two Intel X710 cards, one Intel i350 mLOM adapter, and one Intel i350 LOM, and you enable OptionROMs for all these adapters. | 2.0(13e) | 3.0(3a) |
CSCva93943 |
Foreign configuration import fails when a drive group is set to transport ready state and a partial set of drives are removed from the system and re-inserted back into the same system, followed by a system reboot. |
2.0(13e) | 3.0(3a) |
CSCva76667 |
On the 3260 server, the DHSP in transport ready state, after a server reboot, recognizes the DHSP as a foreign configuration. This could occur when drive groups with DHSP are set to transport ready state, and the system reboots with the drives still connected. |
2.0(13e) | 3.0(3a) |
CSCva89367 |
On the 3260 server, the amber LED light switches on when the SSD boot drive in the rear is not present. |
2.0(13e) | 3.0(3a) |
CSCux87057 | On the
3260 servers, the SAS expander firmware update occasionally displays the error
message on the host if MSM is installed:
Communication Lost on enclosure X. A similar error message is also seen in the storage log, in the standalone Cisco IMC web UI. |
2.0(9h) | 3.0(3a) |
CSCva53443 | Qlogic 8442T ISCSI LUN is not visible during SLES 12.1 Installation. This happens when the LUN has an inbox driver (version 2.7.6.2) for ISCSI. | 2.0(13e) | 3.0(3a) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCun71765 | The
10GE LOM port (X540 based) flaps when the host reboots while the CIMC is in
Shared LOM 10G network mode. This event may drop connections to the CIMC
including the Virtual Media and vKVM.
|
2.0(4c) | 3.0(3a) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvc45069 |
While updating the firmware components using Non Interactive HUU, the update may fail with the error message - Firmware update failed for CIMC, Error - Operation failed. The current operation failed. CIMC may be running any critical operation or in error state. Retry after sometime or reboot CIMC if necessary. This happens because of an incomplete firmware update triggered previously. |
3.0(1c) |
3.0(3a) |
CSCvc58466 |
When you update the server firmware using the update-all option of HUU, the Fusion IO 6400 G firmware is not updated. However, HUU's verify update status indicates that the firmware is updated. |
3.0(2b) |
3.0(3a) |
Defect ID | Symptom | First Affected Release | Resolved in Release |
CSCvc56390 |
While accessing Cisco IMC web UI using Google Chrome or Microsoft Edge browsers, some of the options in the drop-down menu do not appear as expected. |
3.0(1c) |
3.0(3a) |
Defect ID |
Symptom |
First Affected Release | Resolved in Release |
---|---|---|---|
CSCvc25363 |
Unable to hide or unhide virtual drives using XML API. |
3.0(2b) |
3.0(3a) |
Open Caveats
The following section lists open caveats.
Open Caveats in Release 3.0(3)
Open Caveats in Release 3.0(3e)
The following defects are open in release 3.0(3e):
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvg05613 |
PID information of the following drives is not reported correctly:
|
Power off the host and update the CMC with the latest S3260 PID catalog. |
3.0(3e) |
Open Caveats in Release 3.0(3a)
The following defects are open in release 3.0(3a):
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvb11910 |
M3 servers may become unresponsive during system BIOS POST at the 'Configuring platform Hardware' stage with a CATERR error in the system event log. |
Enable the Fault Resilient Booting (FRB) timeout for an automatic recovery. |
3.0(3a) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvd84866 |
On the S3260 server with dual controllers, when you hot swap all of the physical drives (56) without AC cycle or rebooting the host, the old physical drive data continues to remain in the web UI and PMCLI. This only happens on systems where all the 56 drives are present, and multiple virtual drives are configured. |
Toggle the server's blade power. |
3.0(3a) |
CSCvb89330 |
On the C460 M4 servers, when you downgrade firmware using NI-HUU to any 2.x release firmware, multiple fan sensor failure events are observed momentarily. This might occur after you manually power cycle the server post the update. |
None. |
3.0(3a) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvd54828 |
The RAID controller encounters an error and resets. This happens when you use an external SATA solid state drive (SSD) and not an SAS SSD. |
None. |
3.0(3a) |
CSCuv67943 |
On the C3160 server, the MSM Application displays a pop-up message reporting a defective slot. However, the error is displayed for one slot number below it. For instance, if slot number 31 is a defective slot, the error displays slot 30 as the defective slot. |
Add a single number to the error message to view the correct slot number. |
3.0(3a) |
CSCva90939 |
On the S3260 server, the physical and logical sectors of physical drives in a MegaRAID Storage Manager (MSM) are shown incorrectly when drives are unzoned from one server and rezoned onto another server on the S3260 server node configurations. |
Refresh the MegaRAID Storage Manager (MSM) screen. This displays the physical drive information correctly. Alternatively, you can use the Cisco IMC storage page to view the physical drive's physical and logical information. |
3.0(3a) |
CSCvd25263 |
In rare situations, the Cisco 12G SAS Modular RAID Controller may encounter a multi-bit ECC error during sustained heavy IO load. |
Replace the controller with a new one and return the old controller. |
3.0(3a) |
CSCvd07355 |
On the S3260 servers, enabling or disabling connection management results in unpredictable I/O performance. This happens when the host is online. |
Move the host offline before enabling or disabling connection management. |
3.0(3a) |
CSCvd18495 |
On the C460 M4 server downgrading the firmware on the 10GE LOM port (X540 based) from release 3.0(3) to an earlier release fails and the following error message is displayed: ERROR LOM Firmware EEupdation failed (Error Code: 2705) |
None. |
3.0(3a) |
CSCvd10359 |
Downgrading the firmware version of the Intel X540 PCIe adapter from 3.0(3) version to any previous versions fails and HUU displays the following failure message: Intel X540 PCI adapter update failed (Error Code: 3115) |
None |
3.0(3a) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvc17387 |
On some C220 M4 servers using a 770 watt power supply unit (PSU) and attached to a UPS, a PSU error is displayed when you upgrade the firmware to release 2.0(13e). The error might occur as a result of noise generated by the UPS. |
None. |
3.0(3a) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvd78351 |
While trying to perform a Cisco IMC configuration import using the UCSCFG utility, importing Cisco IMC data fails and an import failure message is displayed. This happens when the power characterization status is running or if it is required to be run. |
Run power characterization manually before importing or exporting the Cisco IMC configuration. |
3.0(3a) |
Open Caveats in Release 3.0(2b)
The following defects are open in release 3.0(2b):
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvc31545 |
You cannot configure KMIP setting using Cisco IMC Import or Export options. |
Manually configure the KMIP setting on each server using XML API, web UI, CLI. |
3.0(2b) |
Open Caveats in Release 3.0(1c)
The following defects are open in release 3.0(1c):
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvb49288 |
In the web UI, when the field Percentage Life left shows a percentage of below 35%, the status bar is displayed in red, but no fault engine entry is generated. |
None. The Percentage Life Left field in the UI just represents an advisory warning. |
3.0(1c) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvb96598 |
After upgrading the server to release 3.0(1x), when you try to re-insert a boot device using the 'CTRL-C' utility on the SAS HBA controller, the default add key '+' does not function as expected. The Boot Order field accepts a value or 0 or 1, which indicates the presence of multiple controllers. However, currently, you are unable to modify or enter a value in the field. This happens when you upgrade from previous releases such as release 2.0(10) or 2.0(13). |
Use the 'INS' key instead of the default '+' key in the CTRL-C utility to re-insert the boot device. |
3.0(1c) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvc25435 |
HDD firmware continues to show an older version after an upgrade using the host update utility. This happens if you change the firmware to AHCI mode in the advanced BIOS settings. As a result the firmware activation fails. |
Upgrade the firmware in the LSI SW RAID mode. |
3.0(1c) |
Open Caveat in Release 2.0(13h)
The following defect is open in release 2.0(13h):
Defect ID | Symptom | Workaround | First Affected Release | ||
CSCva96401 | On the
C220 M4 and C240 M4 servers, installed with 1227, 1387 or 1385 VIC adapters,
intermittently, upon rebooting the server, the VIC adapters get mapped out.
|
None. | 2.0(13h) |
Open Caveats in Release 2.0(13e)
The following defects are open in release 2.0(13e):
Defect ID | Symptom | Workaround | First Affected Release |
CSCva38014 | On the
C220 M4 and C240 M4 servers, the system could become unresponsive during BIOS
posting, at the 'Configuring and Memory' stage, and logs the following warning:
A warning has been logged! Warning Code = 0x30, Minor Warning Code = 0x13, Data = 0x10100 |
|
2.0(13e) |
CSCuz94596 | DIMMs are mapped out while testing the reboot process. This issue occurs only when Intel Xeon v4 processors and Montage DIMMs are used, where the DIMM round trip time is greater than expected for the DIMM. | None. | 2.0(13e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCva82566 |
The Intel X520 network adapter may not display the vNIC path in the web UI or command line interface after service profile association. |
None. | 2.0(13e) |
CSCuy16602 |
Resetting the storage controller during an ongoing I/O operation results in a BSOD. |
None. | 2.0(13e) |
CSCuy37152 | On the C220 M4 server, the OMB drive is not marked Bad by the Cisco UCSC-P-12Gbps SAS HBA controller after it fails discovery. | None. | 2.0(13e) |
CSCuz21377 | On the C240 M4 servers, the Web UI and command line interface display only one connector display view (CN0) in the expander attached cases. | See the
storage logs and watch out for these strings:
|
2.0(13e) |
CSCva59776 | On the
C240 M4 servers, a recently inserted drive's LED blinks even when another drive
is issued a Locate LED command.
This is observed with any operation with consecutive Locate LED commands, after a drive has been inserted. |
Note down the physical slot of drive before performing drive removal operation. | 2.0(13e) |
CSCvb00471 | Windows OS crashes with a Blue Screen Of Death due to heavy IO. Multi-bit ECC errors found in the logs. | None. | 2.0(13e) |
Open Caveats in Release 2.0(9c)
The following defects are open in release 2.0(9c):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuw17399 | When you check the transceiver details after an active optical cable of length seven meters is connected from the Cisco UCS VIC 1387 adapter to a Nexus 3016Q switch, it fails to detect the QSFP type. When we check the transceiver details, it does not detect the QSFP type of connector. | None. | 2.0(9c) |
Open Caveats in Release 2.0(4c)
The following defects are open in release 2.0(4c):
Defect ID | Symptom | Workaround | First Affected Release |
CSCut37666 | In the JBOD mode, after creating the precision boot order for the HDDs connected to the Cisco 12G Modular SAS Pass through controller, the HDDs do not appear in the created order. This issue applies to LSI controllers with JBOD capability. | Use F6/Setup Boot order control for controlling the System boot order | 2.0(4c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCus94537 | HDD firmware update using HUU takes time as the HDD firmware is updated sequentially. This increases the time to upgrade a server which has many HDD | None | 2.0(3d) |
Open Caveats in Release 2.0(3d)
The following defects are open in release 2.0(3d):
Defect ID |
Symptom |
Workaround |
First Affected Release |
CSCup56423 | Actual boot order does not have the information to identify which LUN is assigned to LSI sSATA, LSI SATA, and different HDDs in AHCI mode. | Set the ROM mode option to UEFI only. | 2.0(3d) |
CSCun24358 | C220 M4 and C240 M4 servers do not reboot on pressing F10 after changing the adapter settings using HII interface from BIOS setup. The servers continues to boot and the new settings do not take effect. | Manually reboot the servers. | 2.0(3d) |
Open Caveats in Release 1.4(7)
The following defects are open in release 1.4(7):
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCud18756 |
LSI storage controllers with external ports (-8e cards) do not show up in CIMC local storage management. |
None. |
1.4(7) |
Known Behaviors
The following section lists known behaviors.
Known Behaviors in Release 3.0(3)
Known Behaviors in Release 3.0(3e)
The following are the known behaviors in release 3.0(3e):
Defect ID | Symptom | Workaround | First Affected Release |
CSCvf96879 |
Activation of HTML based vMedia fails. This happens when you use Google Chrome browser versions 61 or 62. |
Use IE or any other browser. |
3.0(3a) |
Known Behaviors in Release 3.0(3a)
The following are the known behaviors in release 3.0(3a):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuq15528 |
In the legacy boot mode, a few boot options do not appear in the menu or boot override page. This is an intermittent issue and happens when there are multiple boot options with SATA/RAID connected and UEFI boot options are disabled in the boot options. |
If you want to boot from a particular option which does not appear on the menu or the override options, run the policy from Cisco IMC, or press F2 and set the device as the first boot device. All the devices will be listed correctly on the boot options page. |
3.0(3a) |
CSCva57433 | The
Intel Ethernet Converged Network Adapter X710-DA2 PCI Card is unable to launch
the legacy iSCSI option ROM for Port 2. You can view this by searching the SEL
log for the warning message:
Not enough memory available to shadow a legacy option ROM. This happens when the system is configured for legacy boot, and the Intel Ethernet Converged Network Adapter X710-DA2 PCI Card is configured to the iSCSI boot. The card consumes extra runtime Option ROM memory space, and is able to load the Option ROM for only Port 1. Once the Option ROM for Port 1 is loaded, the remaining available Option ROM memory space is insufficient to load the Option ROM for Port 2. |
Use Port 1 for the legacy iSCSI boot with the X710-DA2 PCI card and disable the Option ROM for the rest of the slots and the LOMs. | 2.0(13e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCux43338 |
On the Mozilla Firefox web browser 42.0, when you click the Paste Server Certificate option on the Web UI, the pop-up dialog box eclipses the Save Certificate and Cancel buttons. |
Move the dialog box so as to make the Save Certificate and Cancel buttons visible, or use a different web browser such as Google Chrome or Microsoft Internet Explorer. | 2.0(9c) |
CSCuw76431 |
While installing Red Hat Enterprise Linux 7.1 operating system on the UCS C-Series servers, a critical SEL entry similar to this is created: The 2015-10-12 10:35:07 critical "System Software event: OS Event sensor, unknown event". |
None. | 2.0(9c) |
CSCvd04304 |
When you perform reset to factory defaults after configuring the KMIP certificates and KMIP server details, the existing Cisco IMC and KMIP server certificates are not deleted as expected. |
Scope into any kmip mode in the command line interface and use the restore or delete command. Alternatively, log on to the web UI and use the Delete button on the Secure Key Management tab. |
3.0(3a) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCvc51343 |
C220 M4 and C240 M4 servers with Broadcom 5709 Ethernet PCIe Adapter may crash after heavy network utilization. |
Disable Active State Power Management (ASPM) for PCI devices in BIOS. |
3.0(3a) |
CSCuy05774 |
On the S3260 server, when you attempt to shut down the server on the RedHat Linux OS 7.2, by default the OS boots to the web UI mode (Ctrl+Alt+F7), and the power shutdown command from BMC puts the system to sleep. Any action on the keyboard or the mouse brings the system back to life. The same behavior is observed when the user logs in as root. |
Use the shell prompt interface (Ctrl+Alt+F2)and log in as root. |
3.0(3a) |
CSCvc81096 |
M3 or M4 servers are difficult to detect whenever the server is pulled out. M3 servers need an "S1" display for backward-compatibility since they cannot support multiple controllers, and M4 servers need an "S1-MZ1" display since these support multiple controllers. This happens when you configure zoning on the server and then pull the server out. |
None. |
3.0(3a) |
CSCux20272 | On the C240 M4 servers, Redhat Enterprise Linux OS version 6.5 fails to boot after installation. This happens when you install the OS using a PXE or DVD image. | During the OS installation, do not select the Desktop Packages option. | 2.0(10b) |
CSCva44733 | When Option ROM is disabled in the PCI slot configuration, storelib library is unable to inventory the disks. | Keep the Option ROM enabled. | 2.0(13e) |
CSCvb34628 | On rare
occasions, while updating the firmware of the storage controller, it fails with
a "Flash Programming error" resulting in a failed controller requiring Return
Material Authorization (RMA).
This only happens when the firmware update is issued while there is a battery super capacitor relearn in progress and the relearn completes before the flash write is complete. |
If this
issue occurs, do the following:
|
2.0(13e) |
CSCva55926 | Redhat Enterprise Linux OS version 7.2 fails to install on Qlogic 8442T ISCSI LUN with an 'Unknown error occurred' message. | None. | 2.0(13e) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvd65151 |
RedHat Enterprise Linux operating system version 6.8 does not boot through the iSCSI LUN if you choose desktop packages during the OS installation. This happens only when the OS is installed in an iSCSI target, and not on a local storage or SAN target. |
If desktop packages are mandatory for the installation, use RedHat Enterprise Linux operating system version 6.9. |
3.0(3a) |
CSCuz28948 |
On the C460-M4 servers, due to ESXi vFlash on the SSD LSI driver issue, the RedHat Enterprise Linux virtual machine crashes. This happens when several IOs are running with backup software. |
Disable the vFlash. |
3.0(3a) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvd34692 |
While trying to initiate a Delay firmware update using UCS Configuration Utility, NIHUU fails to trigger the update. This happens when you set the one-time boot order using KVM or web UI. |
Cancel the request and set the one-time boot order using CLI. |
3.0(3a) |
CSCvc78162 |
While configuring a boot order, when you enable IPv6 before exporting the Cisco IMC tokens to a text file (using the UCS CFG tool in Windows), the 'V6-Enabled' token is displayed as 'Disabled' even when IPv6 is displayed as enabled in Cisco IMC. |
Use the web UI, command line interface or XML API interface to get the 'V6-enabled' token status back to 'Enabled'. |
3.0(3a) |
CSCvc78173 |
When you configure a boot order from the web UI use the set command to set the boot order, an error message 'class name tag missing' is displayed. This happens when you import the boot order to a text (input) file using the UEFI shell and the boot order help content is a part of the input file. |
Delete the help content and retain the set parameter data in the input file. |
3.0(3a) |
CSCvc56345 |
On the S3260 servers, when you downgrade release 3.0(3) to an earlier version using the HUU, CMC1 and CMC2 fail to get activated. This happens when the single server dual SIOC function is enabled. |
Disable the single server dual SIOC option before downgrading the server. |
3.0(3a) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuu59408 |
On the Nexus 7018 switch version 7.2.0 (where the fabric extender N2232PP uplink is connected to only one F2 Module port, and the host interface connected to the physical host UCS is shared with the storage virtual device), reloading the F2 module post the module uplink to the host interface results in the DCBX PDU acknowledgment getting lost. |
In the owner virtual device of Nexus 7018 switch, flap the host interface (HIF) port of fabric extender so that the DCBX exchange is initialized. | 2.0(6d) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvd58182 |
On the C220 M3, C240 M3, C22 M3 and C24 M3 servers, the Java based KVM fails to launch. This happens when you use Microsoft Internet Explorer browser with Java version 1.8 (update 121). |
When the security warning pops up on your screen during the launch, click Cancel. The KVM console then launches successfully. |
3.0(3a) |
Known Behaviors in Release 3.0(1c)
The following are the known behaviors in release 3.0(1c):
Defect ID | Symptom | Workaround | First Affected Release |
CSCva99738 | You cannot save the BIOS setting changes using the BIOS option 'Save and Exit' when you are logged in with user privileges. This happens only when you log on to the BIOS setup area in the user mode. | Press the key F10 to save and exit. | 3.0(1c) |
CSCvc14144 | When you update the BIOS with the Enhanced Intel Speedstep Technology (EIST) disabled during setup, power characterization fails to occur, and its status is displayed as 'Not Run'. | None. | 3.0(1c) |
CSCva67765 | On the C460 M4 servers, after you change the VLAN settings using the Cisco IMC F8 configuration menu, the VLAN settings are correctly applied, but do not display completely on the configuration menu. | Wait for two minutes or more before pressing the F5 button to refresh the screen. | 2.0(13e) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvb77846 |
When you launch the HTML based KVM on the Safari browser without installing the certificate properly, the HTML based KVM fails to launch. |
Complete the
following steps to install the certificate:
The certificate is installed. You may use this certificate for all communications with the server. |
3.0(1c) |
CSCva43470 |
Activating virtual media on the HTML based KVM consoles fails on the Mozilla Firefox browser version 32.0. |
Use Mozilla Firefox browser version 38.0 or later, or use different browser such as Google Chrome or Microsoft Internet Explorer. |
3.0(1c) |
CSCva05249 | Virtual Media data transfer on the HTML based KVM console takes a lot of time. | Use Java based virtual media with the encryption disabled. |
3.0(1c) |
CSCuy92283 | LDAP user authentication fails when you download the CA Chain certificate to Cisco IMC, and certificate binding is enabled. | Convert the CA Chain certificate, which is in the .p7b format, to the PEM format before downloading to Cisco IMC. | 2.0(13e) |
CSCuz82915 | When Redhat Linux is in the UI mode, and you enable the scroll key, it is not displayed on the HTML KVM window. | None. Scroll lock is not supported by Redhat in the UI mode. | 2.0(13e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCvc08224 |
Updating the HDD firmware on VMware operating systems using the PMCSSACLI utility fails when you enter the command: pmcssacli ctrl slot=1 pd CN0:1:1 flash file=firmware.bin mode=7 immediate=enable. The firmware update is successful only if you use a forced flag in the command. This happens because a remote connection environment between the server or client SSACLI does not support command prompts in VMware. |
Use a
force flag option as shown in the example:
pmcssacli ctrl slot=1 pd CN0:1:1 flash file=firmware.bin mode=7 immediate=enable forced. |
3.0(1c) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvc06814 |
The latest non-interactive HUU Python script fails to retrieve cookies and update the firmware components in Release 3.0(1). |
Follow
these guidelines to resolve the issue:
|
3.0(1c) |
CSCvc38739 |
After updating firmware using the non-interactive HUU script, the firmware output summary occasionally displays a timeout error such as this: Firmware update failed for CIMC - <IP>, Error - Firmware update failed because it timed out. Check host for details. Despite the error message, the firmware update might be successful. |
Check whether or not all firmware components are updated successfully. |
3.0(1c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCux87650 | On servers with VMware ESXi 5.5.0 or later, the storecli is able to identify the adapter but unable to communicate with the storage controller. | Disable
the affected module from the ESXi command line and use the following command to
communicate with the controller:
|
2.0(10b) |
Defect ID |
Symptom |
Workaround |
First Affected Release |
---|---|---|---|
CSCvb78527 |
When you log on to Cisco IMC using Microsoft Internet Explorer and click the Help button, the page prompts you to enable pop-up windows. After you enable the pop-up window and Internet Explorer reloads, the icons on the page are not displayed, and the Help window fails to open. |
Use the Google Chrome or Mozilla Firefox browser. |
3.0(1c) |
CSCuz83739 |
On the HTML based KVM console, occasionally when you try to map an image in the virtual media using the drop and down method, the virtual media stops responding. |
Use the Browse option to map the virtual media image. |
3.0(1c) |
CSCvb43134 |
After upgrading the firmware to 3.0(1) from a previous version, upon logging in for the first time, the page displays the old web UI instead of the new HTML5 based UI. |
Refresh the web browser. |
3.0(1c) |
CSCvb67922 |
A Native Library error is displayed when you launch the KVM console with multiple (pre-existing) Java versions. |
Complete
the following steps to disable multiple Java versions on your machine:
|
3.0(1c) |
CSCvb66685 |
On the HTML based KVM console, the 'CTRL' and 'ALT' keys do not function. |
Create user-define macros using the option Macro > Manage or use the Java based KVM. |
3.0(1c) |
CSCuz68208 |
Unable to maximize the HTML based KVM console to full-screen mode on the Microsoft Internet Explorer. |
Use the Google Chrome or Mozilla Firefox browser. |
3.0(1c) |
CSCuz39581 |
You cannot launch a Java based KVM on a browser having Java 8 Update 77. |
Use the latest Java version available, which is Java8 Update 92 or 91. Or use Java 8 Update 45 or below. | 2.0(13e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCvb17203 | XML API operations using the commands CURL or POST in a web browser, in release 3.0, do not work with Transport Layer Security (TLS) versions 1.0 and 1.1. | Upgrade to TLS version 1.2. | 3.0(1c) |
Known Behaviors in Release 2.0(13e)
The following defects are known behaviors in release 2.0(13e):
Defect ID | Symptom | Workaround | First Affected Release |
CSCux72847 |
PXE boot from second 10 GE LOM port does not work. This issue may occur when PXE boot is configured to boot from the second 10GE LOM port, and the SAS controller Option ROM is also enabled and loaded. |
Disable the SAS or LOM0 (1GE) Option ROMs to free up enough space to load both the 10GE Option ROMs. |
2.0(13e) |
CSCuy15543 | On the Cisco IMC Web UI and CLI the actual boot order is displayed incorrectly when you configure the IpmiBootOrder from Cisco IMC using the Configpolicy.xml file that is used to configure the precision boot order policy. | None. The incorrect boot order should be ignored. The functionality works as expected and the BIOS setup displays the actual boot order correctly. | 2.0(9e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCux92616 |
With the client system running Java version 1.8 and update 66, KVM crashes while trying to activate vMedia and accept the pop-up prompt for unencrypted vMedia session. |
Enable virtual media encryption using the Cisco IMC Web UI to avoid this pop-up. |
2.0(13e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuy62185 |
Unable to access the Fast Utility option by pressing the Ctrl+Q keys, when the port is configured with iSCSI. |
Enable port 60/64 emulation under USB configuration in BIOS. |
2.0(10b) |
CSCuz55512 |
SLES11 SP3 OS legacy installation becomes unresponsive on the C220 M4 and C240 M4 servers with inbox drivers for UCSC-PSAS12GHBA. |
None. Use async drivers. |
2.0(13e) |
CSCuy12854 |
All Drives except boot drives are marked as Offline by UCSC-PSAS12GHBA on Windows. |
None. |
2.0(13e) |
CSCuv51716 |
The C240 M4 servers connected to a Magma Chassis GPU Expander with Multiple Tesla (k40/K80) cards and running RedHat Enterprise Linux 6.x operating system occasionally become unresponsive during a reboot. |
Hard reboot the server. |
2.0(9c) |
CSCuw86750 | When physical drives containing all virtual drives are removed or replaced, the system displays a fault "configuration lost" which remains unchanged until a virtual drive is created or the configuration is cleared using WebBIOS or Ctrl +R function. |
Reboot to see if the error is cleared. In most cases, it gets cleared. If the error is not cleared, create a virtual drive or clear configuration using Web BIOS or the Ctrl+R function. |
1.5(1) |
CSCux44506 | If a boot virtual drive is marked hidden after setting a different virtual drive as boot drive, and if the system is running from the previously configured boot virtual drive, the system may shut down based on the operating system. | None. | 2.0(9c) |
CSCuz61344 | While trying to login into standalone Cisco IMC version 2.0.9 using CLI or GUI the interface becomes unresponsive. Sometimes an error is displayed, but most times it is unresponsive. Thsi happens due to LDAP group authorization in Cisco IMC. |
Remove the affected LDAP group from the Group Authorization options or resolve the circular loops in the AD database. Modify search-group-depth to a value between 1-3. |
2.0(9d) |
CSCuz93611 | When a Virtual Drive or a Drive Group is set to Transport Ready and a member physical drive is removed, the Virtual Drive or Drive Group cannot be deleted as it is blocked and also Transport Ready state cannot be cleared since Transport Ready is only for Optimal VD or DG. | Remove all members of the VD/DG and reinsert and then continue with next steps. |
2.0(13e) |
CSCva17225 |
Even after the PowerSave command has been sent to all the physical drives, Samsung and SanDisk SAS SSDs will remain active. This is because they do not support the Start Stop Unit (SSU) command. |
None. |
2.0(13e) |
CSCuw55009 |
On the 3260 servers, while upgrading to or downgrading from SAS firmware supporting 240 VD firmware, these issues are seen: During an upgrade, auto-rebuild does not get initiated, and during a downgrade, consistency check and secure erase operations do not resume. |
None. | 2.0(9) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuz48865 |
Unable to downgrade the host firmware from 2.0(13x) version to 2.0(2x) versions. |
Downgrade the firmware from 2.0(13x) to 2.0(6f) first and then downgrade it to 2.0(2x) versions. |
2.0(13e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCun50408 | Creating VD from StorCli and WebBIOS, the default disk policy shown after creation is inconsistent in different UI. MegaRAID Storage Manager shows Unchanged and StorCli shows "Disk's default" | None. Both Unchanged and Disk's Default means the same in this case. Cisco supported Drives have disk cache policy = Disabled so in this case the Disk's Default or Unchanged refer to the same indicating the Disk cache is disabled. | 2.0(4c) |
CSCuq35761 | LSI applications such as StorCli and MSM and CIMC Storage management allows JBOD with Operating system or File system to be converted to Unconfigured Good drives without meaningful error message indicating there could be data loss in such cases. | Users should be aware that there is going to be data loss when JBOD which has OS or File system is converted to Unconfigured Good. LSI Applications like MSM and StorCli prompt users with "Are you sure" message so users need to be careful to understand there will be data loss in such cases if they chose to convert JBOD with OS or File system to Unconfigured good drives. CIMC storage management allows JBOD to be converted to Unconfigured Good without any Warning Pop-Up message. Again users need to be make sure that there is no OS or Filesystem when they choose to convert JBOD to Unconfigured Good drives. | 2.0(4c) |
CSCus82741 | LSI SWRAID driver with RHEL displays "Buffer IO Error" in the messages file when RAID INIT operation is done. | None. | 2.0(4c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCva77821 |
Few components such as BIOS, BMC, CMC fail to get activated while upgrading from 2.0(7e) to 2.0(13e) using non-interactive HUU. |
Upgrade from 2.0(7e) to 2.0(9l), then upgrade to 2.0(13e). |
2.0(13e) |
Known Behaviors in Release 2.0(12b)
Following is the known behavior for Release 2.0(12b):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuz30387 | On the C460 M4 servers, host serial port (PMCLI) does not work when the host is powered off. | Power on the host. | 2.0(12b) |
Known Behaviors in Release 2.0(10e)
Following is the known behavior for Release 2.0(10e):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuy42320 | If firmware is downgraded to legacy firmware, or Transport Ready is disabled in the new firmware, Transport Ready is cleared in NVRAM. But if the firmware is not a legacy firmware or it does not have Transport Ready implementation, Transport Ready is not cleared. In this case if Transport Ready aware firmware is flashed again, Transport Ready DGs will reappear. You are then required to manually clear Transport Ready. | None. | 2.0(10b) |
CSCux62038 | When the Qlogic QLE8362 card is populated in the set-up, the server is unable to boot to BIOS (F2 menu). | Use Cisco IMC to configure all BIOS related settings. | 2.0(10b) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuy46516 | When connected to a Magma chassis with the K80 populated in the chassis, intermittently the server becomes unresponsive during a BIOS POST. | None. | 2.0(10b) |
Known Behaviors in Release 2.0(9d)
Following are the known behaviors for release 2.0(9d):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuu56166 | On the C3260 server, after you perform expansion or raid-level migration operations Virtual Drives (VD) do not display the updated size. | Complete the following steps:
|
2.0.7(d) |
Known Behaviors in Release 2.0(9c)
Following are the known behaviors for release 2.0(9c)
Defect ID | Symptom | Workaround | First Affected Release |
CSCun99348 | When virtual KVM is disabled, the Play Recording action on the Troubleshooting screen fails. | Enable Virtual KVM on the Remote Presence tab. | 2.0(1) |
CSCuv08978 | Management port MTU cannot be configured due to hardware limitations. | None. | 1.5(4) |
CSCuj36245 | After restoring to factory defaults, when you import the BIOS tokens on the target machine, the values remain unchanged. | Power on the target machine and try the import operation after the BIOS post is completed. | 2.0(1) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCun99297 | Cannot select specific USB thumb drive under boot option priorities. | Use F6 from the boot selection menu to select specific USB drives. | 2.0(1) |
CSCuo08591 | System becomes unresponsive in the POST after the SD card removal when the host is powered on. |
|
2.0(4c) |
CSCun91835 | Boot order varies when enabling or disabling the Option ROM. | None. | 2.0(1) |
CSCur61234 | In the secure boot mode, a security violation error is triggered. This issue could also occur while trying to perform an AC power cycle, when the power characterization is enabled in the UEFI secure mode. | None. | 2.0(4) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCum87051 | Random behavior of system freeze at boot @ BIOS POST screen for around 2 minutes followed by "Waiting for Battery Pack" message on LSI Ctrl-R BIOS for another 2 minutes. This only happens if there is a learn cycle pending for the supercap and the host is restarted (either AC/DC/reboot). At all other reboot/power cycle, this does not happen. | There is no work-around at this time. | 2.0(4c) |
CSCuu86314 | On M4 servers, the iMR (Zero-memory) RAID Controller supports up to 32 virtual drives, but the command to create virtual drives in a single drive group allows only 16 virtual drives. | None. The RAID controller supports 32 virtual drives across all drive groups and only 16 drives in a single drive group. | 2.0(6) |
CSCum87232 | Cisco IMC storage BBU info shows the Pack Energy value below the design capacity. This is also seen in the storcli /cX /cv show all command. On the current shipping 6G SAS RAID Controllers with Supercap, the Pack energy is always above the design capacity. This is a change in behavior confuses the user and makes the user think the supercap has or is going bad and gets a worrisome situation of the data integrity. | There is no work-around at this time. This is just a display issue and does not impact the actual functionality or data integrity. | 2.0(4c) |
CSCuw69844 | On the servers with 2008M-8i, the VMware ESXi 5.5 Update 1 install fails while loading the installer. |
|
2.0(7) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuw42070 | The MegaRAID Storage Manager fails to detect a new 6TB HGST drive with yellow amber LED. This happens when the drive is corrupted and displays an SAS link failure. | None. | 2.0(8) |
CSCuw55045 | SAS Flash and MSM utilties are unable to downgrade the IT firmware if the Network Virtualization (NV) data version changes. To downgrade the NV data version, use the FlashOEM tool bundled with the Host Upgrade Utility (HUU). | Do not use SAS Flash and MSM utilities to downgrade the IT firmware. Use these to only use the HUU. | 2.0(9c) |
CSCuw09414 | Powering off Virtual machines (VM) with the Virtual Graphics Processor unit (vGPU) takes 90 to 120 seconds in VMware ESXi 6.0. | Power off smaller number of VMs at one time. | 2.0(4c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuw80507 | According to the knowledge base at https://access.redhat.com/solutions/21322, using IPMI commands on the Red Hat Enterprise Linux results in the over use of CPU resources. | Add the following command at the end of the kernel line in /etc/grub.conf: ipmi_si.kipmid_max_busy_us=<time in microseconds> | 1.5(2) |
Known Behaviors in Release 2.0(8d)
Following are the known behaviors for release 2.0(8d):
Defect ID | Symptom | Workaround | First Affected Release |
CSCul16923 | The fault code F0181 is raised by CIMC when the local disk is removed while the rack server was in use. This fault is visible through CIMC WebUI, CLI and SNMP interfaces. But the same fault is not retrievable through the XML API interface. | None. | 1.5(4) |
CSCuj40520 | Upgrading firmware with Host Upgrade Utility (HUU) can cause temporary storage faults while the upgrade is in progress. These faults are benign and will clear once the upgrade is complete. | None. | 1.5(4) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuq23984 | Cisco IMC does not respond during OOB update of utility virtual drives (SCU/HUU/Drivers) on flex flash. | It is recommended that host reboot actions are not performed while running OOB update of utility virtual drives on flex flash. | 2.0(3d) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuv63101 | User gets logged out of the Web UI occasionally, after upgrading the Cisco IMC firmware from 2.0(6) to 2.0(8). This happens when browser cookies are not cleared. | Clear the browser cookies. | 2.0(7) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCun00121 | Cannot create boot option for partitions in SD card. | None. | 2.0(1) |
CSCul84767 | The system locks up while running memtest86 from memtest.org. The problem is seen only with memtest86 from memtest.org. | Do no use memtest86 from memtest.org on C460 M4. Please use PassMark or any other memory test tools that have the support for IvyBridge EX platforms instead. | 2.0(4c) |
CSCun02543 | Port number attributes are missing in the actual boot order for the FC and FCOE cards. | None. | 2.0(1) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCut92393 | On the C240 M4 servers, on rare occasions, the Cisco 12 Gigabyte SAS Modular RAID Controller displays an error when you try deleting a virtual drive. | None. | 2.0(6) |
CSCuv34371 | When creating new virtual drives of any RAID type, the write cache policy defaults to 'write through' even with a fully functional BBU or super-capacitor battery. When a BBU is present, the default write cache policy should be 'write back with good BBU'. This happens on the C240 M4 and C220 M4 servers with 12 gigabyte SAS mezzanine RAID controllers. | In the standalone mode, on the Ciso IMC storage tab of the Web UI, edit the virtual drive to set the write caching policy to 'write back with good BBU'. You can also modify the setting using the LSI command line option rom config utility . | 2.0(3d) |
CSCuv36714 | The MegaRAID Storage Manager displays consistency check errors on RAID 1 volume in Windows. This happens when you try writing data to the drive 20 to 30 minutes after a consistency check (which appears to be normal). | This is a known Microsoft limitation. For more information, see https://support.microsoft.com/en-us/kb/2713398 | 2.0(4c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuv04922 | On the C240 M4 server, A "PCI Resource Error" message is seen with the Magma Chassis GPU Expander configuration due to a CPU I/O space limitation which supports a maximum of 64K. This happens when all or some of the PCI slots are occupied by different third party adapters. |
For Nvidia Grid K1 configuration: (where one Nvidia Grid K1 is internally connected on the C240 M4, and two Nvidia Grid K1 adapters are externally connected through the Magma Chassis)
For Nvidia Grid K2 configuration: (where one Nvidia GridK2 is internally connected on the C240 M4, and four Nvidia Grid K2 adapters are externally connected through the Magma Chassis)
|
2.0(4c) |
Known Behaviors in Release 2.0(7d)
Following are the known behaviors for release 2.0(7d)
Defect ID | Symptom | Workaround | First Affected Release |
CSCuv34476 | On the 3260 server, KVM fails to launch and displays the following message: "Unable to Launch the application" . This happens after swapping or changing a CMC and making it active or master. | Regenerate the certificate using the Web UI or CLI and reboot the CMC. | 2.0(7d) |
CSCuv28734 | On the 3260 server, boot or crash file download fails with a Network error, when you use the Chrome 43 version browser for downloading. | Use other browsers or use Chrome version 42. | 2.0(7d) |
CSCuu50850 | On the 3260 server, you cannot establish an IPMI session to a BMC when BMC is reset to factory default. | Reconfigure user using active CMC. | 2.0(7d) |
CSCur77980 | On the 3260 server, unable to configure users after resetting CMC to factory defaults. This issue occurs when you attempt to configure a user with a different index number after the reset. | Use the same index number that was used before the reset to configure a user. | 2.0(7d) |
CSCuu43406 | On the 3260 server, the server does not respond and displays an error message when the GUI is idle for a few minutes. This happens when you use Chrome Version 41. | Use other browsers or use Chrome version 42. | 2.0(7d) |
CSCuu43330 | On the 3260 server, unable to login to Web UI when the login screen is left idle for a few minutes. This happens when you use Crome Version 41. | Use other browsers or use Chrome version 42. | 2.0(7d) |
CSCur60690 | On the 3260 server, configuring a user using the CLI or Web UI fails with the following message: "Error: User with same name <username> already exists." When a user is configured using the IPMI on BMC the local user, database may not sync with the active CMC. Hence when the same user is configured with a different index on active CMC this error occurs. | Check for the user index number on the local user database on BMC using IPMI and use the same index number to configure the user using the active CMC's CLI or Web UI. | 2.0(7d) |
Defect ID | Symptom | Workaround | First Affected Release | ||
CSCuu36101 | On the
3260 server, MegaRAID card does not support raid level migration when the card
has maximum allowed number of virtual drives created on it.
|
Do not create maximum number of allowed virtual drives. | 2.0(7d) |
Known Behaviors in Release 2.0(6d)
Following are the known behaviors for release 2.0(6d):
Defect ID | Symptom | Workaround | First Affected Release | ||
CSCui64842 |
Hardware configuration settings of Broadcom 57810 adapters reset after firmware update. This issue happens on all 57810 adapters. The following settings are reset:
|
Reconfigure the settings. | 1.5(3) | ||
CSCuu35160 | While downgrading or upgrading LSI firmware, Cisco IMC log reports several CMD over OOB errors. This is expected behavior and the error messages are due to the controller being briefly unresponsive on out-of-band during firmware update. | None. | 2.0(3e) | ||
CSCuu36101 | MegaRAID
card does not support raid level migration when the card has maximum allowed
number of virtual drives created on it.
|
Do not create maximum number of allowed virtual drives. | 2.0(6d) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuu56903 | Data traffic between VMs where the vNICs have the same uplink on VIC 1225, could not be switched upstream. |
Assign vnic0,vnic1 pinned to Uplink-1 and vnic6,vnic7 to Uplink-2.
|
2.0(3e) |
Known Behaviors in Release 2.0(4c)
Following are the known behaviors for release 2.0(4c):
Defect ID | Symptom | Workaround | First Affected Release |
CSCut76388 | For the C220 M4 and the C240 M4 servers, power consumption with 1400W PSUs fluctuates when power cap enabled and the power cap value is set towards a lower value within the allowed range. | Set a higher power cap value. For example, if the allowed power cap range is 350W-650W, then set a value higher than 500W. | 2.0(4c) |
CSCuq39610 | The following error appears while configuring SD cards: ERROR_METADATA_EXSISTS | Remove and insert the SD card and re-configure. If the error persist, replace the SD card. | 2.0(3d) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCur74413 | Watchdog timer policy values change while upgrading or downgrading the BIOS firmware between 2.0(3d) and 2.0(3f) versions. | Reset the values after the BIOS firmware upgrade or downgrade. | 2.0(3d) |
CSCut05524 | TxT getting disabled after few reboots. | Use the TPM Clear command in the BIOS to reset the counter and start over again. | 2.0(3e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCus54600 | LSI9271-8i shows Storage Controller Inoperable? fault in UCSM (PMU Fault present in event log) | Replace the LSI9271-8i adapter | 2.0(3i) |
CSCus68862 | Ubuntu (all versions available today) does not have the inbox drivers for any of the IT-based adapters. | None | 2.0(3d) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCut78400 | Resetting a VIC adapter to default configuration, using the CLI command adapter-reset-defaults, may result in changing of the default MAC addresses. This may require configuration of the DHCP and OS to correct the changes to the default MAC addresses. The occurs for releases 2.0(4) and later due to moving of the default MAC address range to address certain VIC relates issues. | None. | 2.0(4c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuq75761 | During installation of Red Hat Enterprise Linux 7, SAN LUNs mapped will not be visible. Server experiences kernel panic, when Red Hat Enterprise Linux 7 OS is installed on local storage and a SAN LUN is mapped. | No workaround. A driver update disk may be available later to address this issue. | 2.0(2c) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuq43129 | OL 5.9 and OL 5.10 operating systems do not recognize QLE2672 SAN LUN during installation. | None. | 2.0(3d) |
CSCuq60947 | Citrix XenCenter 6.2 configured VM instances fails to boot when driver is passed and vGPU is disassociated. |
Perform the following steps to disassociate vGPU from VM instance:
|
2.0(3d) |
Known Behaviors in Release 2.0(3d)
Following are the known behaviors for release 2.0(3d):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuq99268 | For the ESXi 5.5 and later updates, you can install the OS on a disk behind Cisco 9300 HBA using the native inbox driver (lsi-msgpt3). However, lsi_msgpt3 is not fully supported. Therefore it must be disabled and the async drivers must be installed. | After
installing the OS, complete the following steps to install the mpt3sas drivers:
|
2.0(3d) |
CSCup89033 | The Power Monitoring graph is displayed on top of all pages if the Power Monitoring page is loading and you navigate to any other page. | Navigate back to the Power Monitoring page and wait till the page loads and then navigate to any other page. | 2.0(3d) |
CSCuq00837 | On C220 M4 and C240 M4 servers, TPM fails to initialize after installing ESXi 5.1 U2 Patch 05, and enabling and activating TPM and TXT. | No workaround. | 2.0(3d) |
CSCuq04009 | ESXi installer does not detect any SD card in xHCI mode. | Disable USB xHCI mode in the BIOS. | 2.0(3d) |
CSCuo28585 | HII Drive Management and Enclosure Management menu displays only one port/connection (0-3) and not the other (4-7) when an expander is connected to a controller through two ports. | No workaround. | 2.0(3d) |
CSCuq14862 | With inbox IGB driver in SLES 11 SP3, ethtool shows incorrect firmware version for Intel i350 LOM after installing the drivers for Intel i350 LOM from 2.0(3d) drivers ISO(5.2.5). | Update the igb version to 5.2.5. Unload and load the igb. | 2.0(3d) |
CSCuq24196 | After installing the Windows Server 2012 to an iSCSI LUN, few network adapters display a yellow bang in the device manager (code 10) with the following description: This device is not working properly because Windows cannot load the drivers required for this device This occurs only on the NICs that are used for iSCSI boot. |
Perform one of the following: A hotfix is available for Windows 8 and Windows Server 2012. Run this fix in the Windows OS image and then perform iSCSI installs. For more information on the fix, see http://support.microsoft.com/kb/2822241 OR Complete the following steps :
|
2.0(3d) |
CSCup82749 | Windows 2K12 R2 iSCSI Boot with Intel i350 and Pinecrest adapters displays BSOD when it is installed using the inbox drivers. | While installing the W2K12 R2 iSCSI, skip the Intel drivers from the drivers ISO. Reboot the server once the installation is finished. | 2.0(3d) |
CSCuq92331 | Bandwidth test fails while running synthetic benchmarks, like the nvqual. This happens when the processor power management is enabled. | Disable the processor power management option using the BIOS setup. | 2.0(3e) |
CSCuo05774 | Setting the boot mode to UEFI or Legacy requires two reboots for the change to reflect. | Reboot the server twice. | 2.0(3e) |
CSCul04884 | Server enters BIOS setup menu when the boot devices that are configured in the service profile are not found. This impacts only C-series servers that are managed by Cisco UCS Manager. | None. | 2.0(3e) |
CSCuj28644 | UEFI PXE boot or UEFI iSCSI boot does not work when the boot mode is set to UEFI. | Use the legacy boot mode when using PXE or iSCSI boot. | 2.0(3e) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuo26946 | When you upgrade from releases 1.5(x) to 2.0(x) or downgrade from 2.0(x) to 1.5(x) or migrate from legacy to precision boot order, and if the SD card has four partitions, BIOS boot order mismatch occurs for the SD cards. | No workaround. You have to re-configure the boot order. | 2.0(3d) |
CSCuq32910 | When the server boots with 2.0.3d release firmware, it fails to update the HUU firmware version and displays the current version of the Emulex OCe14102/Oce11102 as Not . | Reboot the server. | 2.0(3d) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCup87719 | i350 adapter with default factory configuration dispatches the boot protocol Option ROM only for the first port. It does not dispatch Option ROM for the remaining 3 ports of the i350 card. | Enable the boot option for required ports using boot Util. | 2.0(3d) |
Known Behaviors in Release 2.0(1b)
Following are the known behaviors for Release 2.0(1b):
Defect ID | Symptom | Workaround | First Affected Release |
CSCup49368 | When you click Update All to upgrade from version 1.5.7 to 2.x using the Cisco Host Upgrade Utility the chassis firmware does not get updated. |
Using the Web UI, complete these steps to upgrade the chassis firmware:
Using the CLI, complete these steps to upgrade the chassis firmware:
|
2.0(1b) |
CSCup58906 | When you downgrade to 2.0(1a), Cisco IMC Web UI displays warning messages and critical events. | A/C Power cycle the sever. | 2.0(1b) |
Known Behaviors in Release 2.0(1)
Following are the known behaviors for the Release 2.0(1):
Defect ID | Symptom | Workaround | First Affected Release |
CSCth84883 | The LED sensor color is red or amber or blue (or any supported color) even though the LED state is set to OFF. | Ignore the LED color when the LED state is set to OFF. | 2.0(1) |
CSCtt08424 | Cisco IMC power capping is not supported on VMware ESXi 5.0. | When Cisco IMC is upgraded to 1.4(2), the Cisco IMC will automatically disable power capping. Power capping must manually be re-enabled to use it. | 2.0(1) |
CSCun97225 | When you downgrade from release 2.0(1a) to a 1.5(x) release, you see only seven platform event filters instead of 12 filters. | Restore factory default settings or run the Cisco OEM function command on the ipmitool raw 0x36 0x03 0xAA . | 2.0(1) |
CSCuo40835 | When you downgrade from release 2.0(1a) to a 1.5(x) release, if you have set the SNMP port value to anything other than the default value (161), you cannot reset this number. | Before downgrading, set the SNMP port to 161 or after downgrading restore factory defaults. | 2.0(1) |
CSCun10320 | Cannot upgrade Cisco IMC firmware version from 1.5(3d) to 2.0(1a) using FTP. | Use a browser or SCP client upgrade. | 2.0(1) |
CSCum70086 | Downloaded DVR player fails to play offline for Java versions 6 and below on Windows OS. | Edit and update the script_win.bat file with the correct Java version. | 2.0(1) |
CSCun66062 | While using the CLI to define the precision boot order, if multiple devices' orders are changed by scoping to an individual device, the final order of the devices may not appear as what it was changed to. | Use the rearrange-boot-device command to set the boot order for multiple devices. Or use the Cisco IMC Web UI. | 2.0(1) |
CSCum26002 | A delay occurs while pinging to check the connectivity to the DNS servers before a DDNS update is triggered. | You can manually check the connectivity to the preferred and alternate DNS servers for both the IPv4 and IPv6 addresses the using the ping option available in this release. | 2.0(1) |
CSCun11979 | Cannot configure legacy boot order using the Cisco IMC Web UI. | Use CLI or XML API. | 2.0(1) |
CSCuo71634 | After upgrading the Cisco IMC firmware and activating secure boot mode, when you immediately try to reboot Cisco IMC, it does not respond. | After the upgrade, reboot Cisco IMC after about 10 minutes. | 2.0(1) |
Known Behaviors in Release 1.5.7
Following are the known behaviors for Release 1.5(7):
Defect ID | Symptom | Workaround | First Affected Release |
CSCul62033 | During heavy I/O transactions on the SD card, read errors may be seen in CIMC. | Use Cisco FlexFlash 3.0 cards | 1.5(7) |
CSCua94308 | There is no CIMC notification of Closed Loop Thermal Throttling (CLTT) when it occurs. CLTT happens automatically when the DIMM temperature crosses the UC (upper critical) temperature. | None. | 1.5(7) |
CSCuo18891 | UCScfg_X64.exe batch - ignore set t.txt command displays "Error: Invalid Number of Arguments" error message, when the input file is in Unicode format. | Use ANSI format input file. ( | 1.5(7) |
CSCud84978 | SEL has memory entries, but no entries are seen in the fault page. Cisco UCSM fault codes are unavailable for these SEL. | None. SEL has to be used to decode the memory related events. | 1.5(1) |
Defect ID | Symptom | Workaround | First Affected Release | ||
CSCun77988 | After installation of ESXi in UEFI mode, the OS fails to boot up. The installation completes, but on the subsequent reboot, the server does not boot ESXi OS. |
To resolve this issue, complete these steps:
|
1.5(7) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuo39368 | Nvidia GPU cards non functional or erratic behavior on system beyond 1 TB of memory. | This is an Nvidia GPU limiation due to 40 bit addressing on the GPU's. The memory should be 1 TB or less for the GPU's to be functional. | 1.5(7) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCue88244 | Prepare for removal prepares a Hard drive for removal but LED on the HDD does not blink AMBER to indicate the drive is ready to be replaced. This happens only on direct connect C260 M3 configurations. | None. | 1.5(4) |
CSCui29979 | BBU Charging Status shows either Charging or Discharging all the time. This could lead to confusion to customers as Charging or Discharging indicate that battery is not in optimal state. | Customers should use the BBU Status field to determine if the battery is in optimal state. If the BBU status is optimal, it will indicate a good battery. If the BBU status indicates battery needs replacement, then the BBU is bad and needs to be replaced. Charging Status is working as designed and will always indicate Charging or Discharging because Firmware keeps checking the battery charge and ensures that the charge does not fall below the band gap. It charges the battery when it is in lower limits and once it reaches the upper limit of the band, it will stop charging. There can be leakage current which can discharge the battery and bring it back to lower threshold. When this happens, the firmware initiates charging. | 1.5(2) |
Known Behaviors in Release 1.5(4)
Following are the known behaviors for Release 1.5(4):
Defect ID | Symptom | Workaround | First Affected Release |
CSCul36732 |
SAN boot using Emulex adapters may fail on C-series servers managed by Cisco UCS Manager. This behavior occurs only on servers managed by Cisco UCS Manager. |
During the BIOS post, press the hotkey to enter the Emulex Option ROM configuration screen and enable "EDD", save and exit. |
1.5(4) |
CSCub21433 |
UEFI OS install is not supported on Software RAID (Onboard SCU controller). |
None. Use legacy mode OS installs when using Software RAID. |
1.5(4) |
CSCtz11862 |
Continuous beep sound is heard when the system is switched on. |
Do not switch on the CIMC and the host simultaneously. Switch on the host 3 minutes after switching on the power supply. |
1.5(4) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuj89681 |
After moving an SD card to the single partition mode, if you downgrade to releases prior to 1.5(4x), all 4 partitions are visible in the WebUI/CLI. |
None. |
1.5(4) |
CSCuj84718 |
SD card partition sizes appear as trash values for SCU,HUU and drivers during downgrade. |
Upgrade to release 1.5(4x) and create a single partition, and then downgrade to a prior release. The partition sizes then appear to be 2097151 MB. |
1.5(4) |
CSCuj67995 |
Changing multiple configuration with Port parameter fails from CIMC configuration only. |
Complete the following steps:
|
1.5(4) |
CSCuj52943 |
In the transition from 4 partition configuration to a single partition, only configuration details are modified. Data on the SD remains intact. So after migrating to a single partition (HV), the HV partition will retain SCU data only if SCU has a valid file system during configuration migration. |
After migrating to a single partition (HV) configuration, format and install the required OS on the HV partition. |
1.5(4) |
CSCul50285 |
ucs-c220-m3# scope bios/advanced ucs-c220-m3 /bios/advanced # ucs-c220-m3 /bios/advanced # set ConsoleRedir COM_0 ucs-c220-m3 /bios/advanced *# set BaudRate 115200 ucs-c220-m3 /bios/advanced *# set FlowCtrl None ucs-c220-m3 /bios/advanced *# set TerminalType VT100+ ucs-c220-m3 /bios/advanced *# commit ucs-c220-m3 /bios/advanced # |
Use the following process: ucs-c220-m3# scope bios ucs-c220-m3 /bios #scope advanced ucs-c220-m3 /bios/advanced # set ConsoleRedir COM_0 ucs-c220-m3 /bios/advanced # commit Changes to BIOS set-up parameters will require a reboot. Do you want to reboot the system?[y|N] |
1.5(4) |
CSCue10121 |
The PWRGD Sensor's Normal events are logged in the SEL during the CIMC boot and Host boot. |
These are expected events and can be ignored. |
1.5(4) |
CSCuj41445 |
Auto complete for few fields is done. |
Upgrade to 1.5(x) build. |
1.5(4) |
CSCud17092 |
Occasionally after a CIMC upgrade, one may see an error dialog box "Error: Unexpected error" in Web UI on main page upon the very first login. The Storage data may also be blank or invalid. Sometimes occurs during the very first login after a CIMC upgrade. It may be related to upgrade from 1.4x to 1.5. |
Logging out and back in will fix it, but probably just because it takes time; therefore, just waiting a few minutes and refreshing the WebUI may fix the problem, also. |
1.5(4) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCul56178 |
CIMC limits the configurable vNICs, and usNICs to 229. |
None. The remaining vNICs are reserved for the internal adapter usage. Of these remaining vNICs, 4 are mandatory- 2 eNICss, and 2 fNICs. When you configure 16 vNICs (including the 2 mandatory eNICs), you are left with 229-2(fNICs)-16(eNICs)= 211 usNICs. |
1.5(4) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuj83316 |
The battery is in a degraded state because it requires a manual (user initiated) relearn cycle.This is required of batteries that have been in use for over 1 year to accurately measure the battery's remaining capacity. |
A manual (deep cycle) relearn must be started by the user. This can be done via the MegaCLI utility or from the Storage tab of the server CIMC. A relearn can take several hours and up to a day to complete. It the battery still has sufficient capacity after the relearn is complete, it will go to optimal state and the VDs will switch back to WriteBack mode if that is how they configured prior to the relearn. |
1.5(4) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCtx16030 |
The WebUI DIMM "Operability" field in the memory inventory does not indicate failed DIMMs correctly. |
The issue is observed only in the memory inventory reported by the WebUI. The BIOS reports the DIMM status properly in the BIOS Setup. So, if WebUI shows any DIMM as Inoperable, please check the status of all DIMMs on all the memory risers at Advanced -> Memory Configuration page of the BIOS Setup to get the correct status on the DIMMs. |
1.5(4) |
Known Behavior in Release 1.5(3)
Following are the known behaviors for Release 1.5(3):
Defect ID | Symptom | Workaround | First Affected Release |
CSCui82263 | Downgrading from release version 1.5(3) to 1.5(1) release version does not throw an error in Host Upgrade Utility. | This is not an issue. Though an error is not reported, the update will not proceed. | 1.5(3) |
Known Behaviors in Release 1.5(2)
Following are the known behaviors for Release 1.5(2):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuf52723 | C240 M3 does not power up after firmware upgrade to 1.5(1B). While upgrading via HUU from firmware 1.4(6c) to 1.5(1b), HUU did not upgrade CIMC to 1.5(1b) even though it reported as successfully completed. | Manually force CIMC and BIOS update to fix it. | 1.5(2) |
CSCug78887 | Base Distinguished Name (base-dn) parameter syntax is different in new LDAP implementation. | Use the
following syntax: /ldap # set base-dn DC=Scom,DC=msdn,DC=com
instead of /ldap # set base-dn Scom.msdn.com |
1.5(2) |
CSCuh71550 | With Windows Active Directory, the child domain user login will fail with partial login name. | Provide fully qualified login name to make it work. | 1.5(2) |
CSCuh39061 | Intel VTD and ATS are required BIOS setting for usNIC. However, there is no warning message in CIMC if these parameters are not enabled when usNIC is configured. | Make sure Intel VTD and ATS are enabled in BIOS setting when usNIC is configured. | 1.5(2) |
CSCuf08450 | When upgrading the C24 M3 from 1.4.7a to 1.4.7f using the HUU (option to upgrade all), the servers fans run at almost double the speed they were running at on 1.4.7a. | None | 1.5(2) |
CSCug65160 | Sometimes, a VIC link on a SFP+ copper cable goes down after a VIC reboot or CIMC reboot. Cables whose serial number starts with MOC1238 through MOC1309 could be affected. | AC power cycle the chassis to recover. | 1.5(2) |
CSCtx43305 | The PSU firmware revision may only be partially available when the PSU does not have AC power. | Connect the AC power to the PSU. The full firmware revision will be available. | 1.5(2) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCue10144 | When booting a Cisco C22x or C24x server, RAID levels are displayed when loading the LSI Option ROM. However, not all supported RAID levels are displayed. | This is done to distinguish between different 9240 controllers. Some of them support RAID5, and some do not. There are 2 products under the same 9240 name. However, there is not enough space in the name field to list every possible RAID level supported. This is why a partial list of RAID levels is displayed. | 1.5(2) |
CSCug95648 | BBU charging status always shows as Charging and percentage of charging never reaches to 100%. It always shows 67%. | This is the new change in the firmware. The Battery re-learn cycle is completed successfully and battery is charged back to 67% which is in the band gap where charging will be stopped by LSI firmware and battery will be declared optimal. This is the charge needed to retain data upto 48 hours. The Charging Status showing "Charging" as there will be some leakages and battery will slowly loose charge and hence the battery will be charging. | 1.5(2) |
CSCuh82265 | BBU status is showing as discharging and the charge % is stuck at 64%. Battery replacement alerts on the server. Server is showing battery discharging and there is a moderate alert which says Status: Learning Cycle Needed? | None | 1.5(2) |
CSCud13257 | Hang occurs when using 64-bit MSM 12.08.03.03. | Use 32 bit version of MSM. | 1.5(2) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCui09482 | Firmware Update on Emulex LPe16002 will fail when tried from HUU on certain servers. | Emulex LPe16002 is already at the same firmware level of what HUU is carrying. So effectively an update is not needed. alternatively move the card to another server and try update. | 1.5(2) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCug37639 | When
doing a MIB walk on several MIBs, they give a "No more variables left in this
MIB View (It is past the end of the MIB tree)" error at the end. Failing MIBs:
snmpVacmMIB
Sample good output: [root@pebbles-iptv mibs]# snmpwalk -v2c -c public localhost notificationLogMIB NOTIFICATION-LOG- MIB::nlmConfigGlobalAgeOut.0 = Gauge32: 1440 minutes NOTIFICATION-LOG- MIB::nlmStatsGlobalNotificationsLogged.0 = Counter32: 33 notifications NOTIFICATION-LOG- MIB::nlmStatsGlobalNotificationsBumped.0 = Counter32: 33 notifications [root@pebbles-iptv mibs]# ** Notice MIB ends cleanly, and there is no error. ** Sample bad output: [snmp@sv-repo ~]$ snmpwalk -t 120 -v3 -u glasco -l AuthPriv -a MD5 -A enuf4me2do -x DES -X tqbFjotlCow 14.17.2.45 .1.3.6.1.6.3.16.1.5.2.1.6 SNMP-VIEW-BASED-ACM-MIB::vacmViewTreeFamilyStatus."all".1.1 = INTEGER: active(1) SNMP-VIEW-BASED- ACM-MIB::vacmViewTreeFamilyStatus."_all_".1.0 = INTEGER: active(1) SNMP-VIEW-BASED-ACM- MIB::vacmViewTreeFamilyStatus."_all_".1.1 = INTEGER: active(1) SNMP-VIEW-BASED-ACM- MIB::vacmViewTreeFamilyStatus."_all_".1.2 = INTEGER: active(1) SNMP-VIEW-BASED-ACM- MIB::vacmViewTreeFamilyStatus."_none_".1.0 = INTEGER: active(1) SNMP-VIEW-BASED-ACM- MIB::vacmViewTreeFamilyStatus."_none_".1.1 = INTEGER: active(1) SNMP-VIEW-BASED-ACM- MIB::vacmViewTreeFamilyStatus."_none_".1.2 = INTEGER: active(1) SNMP-VIEW-BASED-ACM- MIB::vacmViewTreeFamilyStatus."_none_".1.2 = No more variables left in this MIB View (It is past the end of the MIB tree) [snmp@sv-repo ~]$ To have, "No more variables left in this MIB View" when there are more mibs left to walk. The final oid seen is 1.3.6.1.6.3.16.1.5.2.1.6, and within the error-status of the get-response packet, we get noSuchName(2), and this should be noError(0). |
None. | 1.5(2) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuc19323 | Sometime with Windows 2008 and IE 8.0 CIMC WEB UI login prompt will not be seen | Add CIMC IP to IE 8.0 trusted sites list. In the Internet Explorer browser window, select Tools -> Internet options -> Security -> Trusted Sites -> Sites -> Add | 1.4(7) |
CSCuh76949 | After clicking on "Add Exception", user is prompted with a window which says "certificate is valid" and the "Confirm Security Exception" button is greyed out. | Clear the cache or refresh multiple times the issue will be resolved. | 1.5(2) |
Known Behaviors in Release 1.5(1f)
Following are the known behaviors for Release 1.5(1f):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuf53059 | FlexFlash operational profile is not preserved on downgrade from 1.5(1x), resulting in all FlexFlash partitions being visible to the operating system. | Set the operational profile again after downgrade. | 1.5(1f) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuf02487 | Creating RAID volumes from Intel RSTe software RAID Option ROM (Control-I) is not supported. | Use LSI software RAID, LSI hardware RAID, or OS SW RAID. | 1.5(1f) |
CSCue72256 | Hard drive Critical events are seen in SEL during server bootup when using Intel RSTe. | This is not a real hard drive fault. The HDD Critical events reported becomes normal after system boots up and can be ignored. If real HDD fault, then Critical event generated on HDD will be persistent and does not indicate normal even after server has booted up and in this case, user need to take action to replace that HDD. | 1.5(1f) |
Known Behaviors in Release 1.5(1)
Following are the known behaviors for Release 1.5(1):
Defect ID | Symptom | Workaround | First Affected Release |
CSCuc75369 | LSI Web BIOS may not launch on pressing Ctrl+H. | During BIOS post, press F6 to bringup the boot override list and select the appropriate entry to launch the web bios. | 1.5(1) |
CSCuc60934 | BIOS Boot order is getting changed when a virtual media device is mounted and unmounted through CIMC WebUI vKVM console or CIMC CLI. | After unmounting the virtual media device, restore the boot order by re-configuring the boot order through either BIOS Setup or CIMC. | 1.5(1) |
CSCtf54851 | Serial port B cannot be enabled for console redirection in the Server Management -> Console Redirection page of the BIOS setup. | Serial port B is primarily used for SOL functionality. The BIOS will start redirecting console messages to serial port B if SOL is enabled. You should enable SOL through BMC to get console redirection messages through serial port B. | 1.5(1) |
CSCth71350 | If the current CIMC networking mode is shipping mode, then the BIOS F8 CIMC configuration utility does not allow a new networking mode and IP address to be set at the same time. | Set the new networking mode, save, then set the new IP address and save again. | 1.5(1) |
CSCtq84425 | When BIOS console redirection is enabled, the keyboard can stop working in the Broadcom PCIe Option ROM at some baud rates. | Disable the BIOS console redirection. | 1.5(1) |
CSCtx27907 | Occasionally, when BIOS starts, the following message is displayed: Error on Getting Cisco IMC IP/MAC Address. | This message can be ignored. | 1.5(1) |
CSCtx92042 | When Broadcom 5709 Gigabit Ethernet adapter is plugged into one of the PCIE slots, the server gets stuck at the BIOS post screen during the booting process. | Upgrade the firmware on the Broadcom 5709 Gigabit Ethernet adapter to version 5.2.7 or later. | 1.5(1) |
CSCtr93601 | BIOS downgrade using the iFlash32 utility, from 1.4.x to the older version 1.2.x fails. | Use the startup.nsh script available in the 1.2.x container for the downgrade. This script will execute the BIOS downgrade successfully. | 1.5(1) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuf05110 | CIMC CLI does not report PID of HDD when using Intel RSTe. | None | 1.5(1) |
CSCue54670 | For a server with Virident card (or any card for which fan control has specific modifications), if CIMC is reset to factory defaults when host is on, then the fan control will go back non-card specific settings. This might imply lower fan speeds and can cause heating up of cards if there are cards present that require higher fan speeds (ex: Virident FlashMaxII card). This is because information about cards is available to CIMC from host, and when a factory default is done, this information is erased. | Reboot the host, so that CIMC can get card specific information and bump up fan speeds as required. | 1.5(1) |
CSCtg92856 | When you power on the chassis with some PS power cables disconnected, the system health LED on the front panel stays green, though some power supplies have no input voltage. | Connect all cables from APC power to the power supply securely. | 1.5(1) |
CSCtz52715 | USB Key which is inserted on a Mac can be forced to be read-only. | Mac users
must unmount the removable drive before mapping.
|
1.5(1) |
CSCua63839 | On some Macs with spaces enabled, the vKVM popup notification that the session has ended can not be closed because trying to click the button causes the focus to move away from the space with the popup. | Move the vKVM main window to the same space with the popup notifier. Then, the popup can be dismissed by clicking on the button. | 1.5(1) |
CSCtr37876 | SNMPv1 traps are sent when SNMPv2 and SNMPv3 traps are enabled. | None. | 1.5(1) |
CSCtx00839 | The KVM screen displays a blank screen. | Use the
physical monitor to change the screen resolution. The following resolutions are
supported:
|
1.5(1) |
CSCtx88183 | After firmware updates, the CIMC Web GUI and CLI might not display the Virtual Drive Information under the Virtual Drive tab and might display the Virtual Drive count as zero even though the Virtual Drive tab displays the list of virtual drives present in the system. | Restart the Cisco IMC. | 1.5(1) |
CSCty58229 | The SNMP Hard Disk Inventory starts numbering with 0 while the CIMC HDD sensor starts with 1. | None. This symptom occurs because the SNMP Hard disk inventory matches with the storage inventory and both starts with index 0. The hard disk sensor numbering starts with 1 because it matches with the label in the SKU. You need to be aware of the difference and map it accordingly while browsing for a specific HDD detail across sensors and storage inventory. | 1.5(1) |
CSCty60975 | The HDD presence cannot be viewed through SNMP. | Use either alternate interfaces or do SNMP query again for the HDD inventory after the action. | 1.5(1) |
CSCua11831 | Duplicate SNMP traps are obtained when you insert Fan 2,4 and 5 in Cisco C22. | None. | 1.5(1) |
CSCuc87936 | "Unable to communicate with FlexFlash" error message is seen after downgrading CIMC to version 1.4. | User should select the Reset Flex Controller button twice if the SD card is of type SD253. If not, select the button only once. | 1.5(1) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCuc52172 | When multiple Intel network adapters are present and you enter the iSCSI configuration from one card, it allows you to change the configuration on all Intel cards. After the change, when one of the cards is removed, it appears that the Option ROM of the remaining cards is overwritten by the card that was removed. | Enter the iSCSI configuration of the card that must be modified. Do not modify other cards when they are visible. This issue is only with iSCSI configuration and not with PXE configuration. | 1.5(1) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCtg25373 | If the number of Virtual Drives created in the LSI MegaRAID controller is greater than or equal to 50, the system will not boot from any of these Virtual Drives. | None. The system boots from MegaRAID Virtual Drives only if the number of Virtual Drives are lesser than or equal to 49. | 1.5(1) |
CSCua03604 | RHEL 6.2 Install to iSCSI target hangs when 2008 MEZZ card Option ROM is disabled on C220/C240 M3 servers. | 2008 LSI OPROM must always be enabled in System BIOS when it is present in the server. If users want to disable it, then during OS Installs, depending on the OS, they would need to blacklist the LSI MegaRAID driver for the 2008 MEZZ card so that system will not hang during install. | 1.5(1) |
CSCts37240 | The following error message is displayed in some LSI RAID controllers when you navigate to Cisco IMC > Inventory > Storage > Battery Backup Unit . Error: required HW is missing ( i.e Alarm or BBU ) The server did not have BBU installed on it and it should have confirmed the absence of the unit. | None. This issue is currently under investigation. | 1.5(1) |
Defect ID | Symptom | Workaround | First Affected Release |
CSCtc22985 | Printing from Web UI is not supported. | Print a screenshot of Web UI. | 1.5(1) |
Known Behavior in Release 1.4(3)
Following is the known behavior for Release 1.4(3):
Defect ID | Symptom | Workaround | First Affected Release |
CSCun24570 | Unable to set all numeric CN from the WebUI. | Update the CN from CLI | 1.4(3) |
Recommended Best Practices
Best Practices to Install VMWare
Workaround for Installing VMWare on First Generation (Gen 1) SD Cards in Expert Mode
Once you start the installer application, find the partition where you want to install VMWare. In the following example the partition is vmhba33:C0:T0:L0.
-
Press Alt+F1 to enter the VMWare recovery console.
-
Create a GUID Partition Table (GPT) on the disk:
/dev/disks # partedUtil mklabel mpx.vmhba33:C0:T0:L0 gpt
-
Verify the GPT:
/dev/disks # partedUtil get mpx.vmhba33:C0:T0:L0
3785 255 63 60817408
-
Return to installing VMWare.
Upgrading BIOS and Cisco IMC Firmware
Cisco provides the Cisco Host Upgrade Utility to assist you in upgrading the BIOS, Cisco IMC, CMC LOM, LSI storage controller, and Cisco UCS Virtual Interface Cards firmware to compatible levels. On the C220 M3, C240 M3, C22 M3, and C24 M3 servers, we recommend that you reboot Cisco IMC before performing the Cisco IMC and BIOS firmware update using NIHUU, HUU, web UI, CLI, or XML API.
![]() Note |
When upgrading the Cisco IMC firmware for the UCS C-series platforms, ensure that you update using the full image (for example upd-pkg-cXXX-mx-Cisco IMC.full.*.bin). |
The correct and compatible firmware levels for your server model are embedded in the utility ISO.
To use this utility, use the Cisco Host Upgrade Utility User Guide which includes the instructions for downloading and using the utility ISO. Select the guide from this URL:
http://www.cisco.com/en/US/products/ps10493/products_user_guide_list.html
Related Documentation
Related Documentation
For configuration information for this release, refer to the following:
-
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide
-
Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide
-
Cisco UCS Rack-Mount Servers Cisco IMC API Programmer's Guide
For information about installation of the C-Series servers, refer to the following:
The following related documentation is available for the Cisco Unified Computing System:
-
For information about supported firmware versions and supported UCS Manager versions for the rack servers that are integrated with the UCS Manager for management, refer to Release Bundle Contents for Cisco UCS Software.