Supported Cisco IMC Faults on Server
Fault Code |
Fault Name |
Message |
Severity |
Cause |
---|---|---|---|---|
F0174 |
fltProcessorUnitInoperable |
Processor [id] on server [chassisId]/[slotId] operability: [operability] |
Major |
Equipment Inoperable |
F0176 |
fltProcessorUnitThermalThreshold Critical |
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal] |
Major |
Thermal Problem |
F0177 |
fltProcessorUnitThermalThreshold NonRecoverable |
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal] |
Critical |
Thermal Problem |
F0185 |
fltMemoryUnitInoperable |
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability] |
Major |
Equipment Inoperable |
F0187 |
fltMemoryUnitThermalThreshold Critical |
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal] |
Major |
Thermal Problem |
F0188 |
fltMemoryUnitThermalThreshold NonRecoverable |
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal] |
Critical |
Thermal Problem |
F0203 |
fltAdaptorUnitMissing |
Adapter [id] in server [id] presence: [presence]Adapter [id] in server [chassisId]/[slotId] presence: [presence] |
Warning |
Equipment Missing |
F0310 |
fltComputeBoardPowerError |
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [id] (service profile: [assignedToDn]) power: [operPower] |
Major |
Power Problem |
F0313 |
fltComputePhysicalBiosPostTimeout |
Server [id] (service profile: [assignedToDn]) BIOS failed power-on self testServer [chassisId]/[slotId] (service profile: [assignedToDn]) BIOS failed power-on self test |
Critical |
Equipment Inoperable |
F0409 |
fltEquipmentChassisThermalThreshold Critical |
Thermal condition on chassis [id] cause: [thermalStateQualifier] |
Major |
Thermal Problem |
F0411 |
fltEquipmentChassisThermalThreshold NonRecoverable |
Thermal condition on chassis [id] cause:[thermalStateQualifier |
Critical |
Thermal Problem |
F0842 |
fltProcessorUnitDisabled |
Processor [id] on server [chassisId]/[slotId] operState: [operState]Processor [id] on server [id] operState: [operState] |
Info |
Equipment Disabled |
F0844 |
fltMemoryUnitDisabled |
DIMM [location] on server [chassisId]/[slotId] operState: [operState]DIMM [location] on server [id] operaState: [operState] |
Major |
Equipment Disabled |
F0868 |
fltComputeBoardPowerFail |
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [power]Motherboard of server [id] (service profile: [assignedToDn]) power: [power] |
Critical |
Power Problem |
F0869 |
fltComputeABoardThermalProblem |
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) thermal: [thermal]Motherboard of server [id] (service profile: [assignedToDn]) thermal: [thermal] |
Minor |
Thermal Problem |
F0918 |
fltComputeABoardMotherBoardVoltage ThresholdUpperNonRecoverable |
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/ [slotId]/[serverInstanceId] is [voltage] |
Major |
Voltage Problem |
F0920 |
fltComputeABoardMotherBoardVoltage UpperThresholdCritical |
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/ [slotId]/[serverInstanceId] is [voltage] |
Minor |
Voltage Problem |
F1257 |
fltStorageFlexFlashControllerInoperable |
FlexFlash Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth] |
Major |
Equipment Inoperable |
F1258 |
fltStorageFlexFlashCardInoperable |
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] FlexFlash Card [slotNumber] on server [id] is inoperable. Reason: [operQualifierReason] |
Major |
Equipment Inoperable |
F1259 |
fltStorageFlexFlashCardMissing |
FlexFlash Card [slotNumber] missing on server [chassisId]/[slotId]FlexFlash Card [slotNumber] missing on server [id] |
Info |
Equipment Missing |
F1260 |
fltStorageFlexFlashVirtual DriveDegraded |
FlexFlash Virtual Drive RAID degraded on server [chassisId]/[slotId]. Reason: [raidState]FlexFlash Virtual Drive RAID degraded on server [id]. Reason: [raidState] |
Minor |
Equipment Degraded |
F1261 |
fltStorageFlexFlashVirtualDrive Inoperable |
FlexFlash Virtual Drive on server [chassisId]/[slotId] is inoperable. Reason: [raidState]FlexFlash Virtual Drive on server [id] is inoperable. Reason: [raidState] |
Major |
Equipment Inoperable |
F1262 |
fltStorageFlexFlashControllerUnhealthy |
FlexFlash Controller [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth] |
Minor |
Equipment Inoperable |
F1004 |
fltStorageControllerInoperable |
Storage Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth] |
Major |
Equipment Inoperable |
F1003 |
fltStorageControllerPatrolReadFailed |
Storage Controller [id] on server [chassisId]/[slotId] patrolReadFailed Reason: [operQualifierReason] Status: [controllerHealth] |
Warning |
Equipment Unhealthy |
F181 |
fltStorageLocalDiskInoperable |
Storage LocalDisk on slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] StorageLocalDisk [slotNumber] on server [id] is inoperable. |
Major |
Equipment Inoperable |
F996 |
fltStorageLocalDiskDegraded |
StorageLocalDisk [slotNumber] Degraded on server [chassisId]/ [slotId]StorageController [slotNumber] Degraded on server [id] |
Warning |
Equipment Degraded |
F1256 |
fltStorageLocalDiskMissing |
StorageLocalDiskMissing on server [chassisId]/[slotId]. Reason: StorageLocalDisk missing |
Warning |
Equipment Missing |
F1005 |
fltStorageLocalDiskRebuildFailed |
StorageLocalDiskon server [chassisId]/[slotId] failed Rebuild. Reason: StorageLocalDisk on server [id] failed rebuild |
Warning |
Equipment Unhealthy |
F1006 |
fltStorageLocalDiskCopybackFailed |
StorageLocalDiskon server [chassisId]/[slotId] failed Rebuild. Reason: StorageLocalDisk on server [[id] failed copyback |
Warning |
Equipment Unhealthy |
F1007 |
fltStorageVirtulDriveInoperable |
Storage VirtualDrive on slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] StorageLocalDisk [slotNumber] on server [id] is inoperable |
Major |
Equipment Inoperable |
F1008 |
fltStorageVirtualDriveDegraded |
Virtual drive [id] on Storage Controller [id] operability: [operability] |
Warning |
Equipment Degraded |
F1010 |
fltStorageVirtualDriveConsistency CheckFailed |
Virtual drive [id] on Storage Controller [id] operability: [operability] |
Warning |
Equipment Unhealthy |
F997 |
fltStorageRaidBatteryDegraded |
Storage Controller [id] on server [chassisId]/[slotId] RaidBattery is Degraded Reason: [operQualifierReason] Status: [controllerHealth] |
Warning |
Equipment Degraded |
F999 |
fltStorageRaidBatteryRelearnFailed |
Storage Controller [id] on server [chassisId]/[slotId] RaidBattery RelearnFailed Degraded Reason: [operQualifierReason] Status: [controllerHealth]. |
Warning |
Equipment Unhealthy |
F1783 |
fltEquipmentTpmTpmMismatch |
Installed TPM is currently in-operable for server configuration |
Warning |
Equipment Inoperable |
F1934 |
fltComputeBoardFailedSecure FuseValidation |
Intel PCH Secure Fuse Verification Failed. Please contact Cisco TAC |
Critical |
Equipment Unhealthy |
F1935 |
fltBiosUnitFD0FailedSecurity Verification |
BIOS FD0 Verification Failed. Please update and reactivate BIOS. |
Critical |
BIOS-Image-Corrupted |
F0305 |
fltComputePhysicalInsufficiently Equipped |
Server [id] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adapters |
Critical |
Insufficiently Equipped |
F0470 |
fltFirmwareUpdatableImageUnusable |
backup image is unusable. reason: [operStateQual] |
Major |
Image Unusable |
F0744 |
fltPowerBudgetPowerCapReached Commit |
P-State lowered as consumption hit power cap for server [chassisId]/[slotId]P-State lowered as consumption hit power cap for server [id] |
Info |
Power Consumption Hit Limit |
F1707 |
fltMgmtHealthStatusHealthCriticalIssue |
Intel ME Node Manager is unhealthy or unresponsive. |
Critical |
Equipment Unhealthy |
F531 |
fltStorageRaidBatteryInoperable |
Storage Raid Battery %s is inoperable: Check Controller battery |
Minor |
Equipment Inoperable |
F1003 |
fltStorageLocalDiskPatrolReadFailed |
%s Local disk %s PatrolRead failed: Please check the storage drive %s |
Warning |
Equipment Inoperable |
F1009 |
fltStorageVirtualDriveReconstruction Failed |
%s Virtual Drive %s reconstruction failed: Reconstruction failed due to configuration mismatch |
Major |
Equipment Degraded |
F2012 |
fltStorageControllerPciEquipSlot Unsecure |
Storage controller %s unable to secure critical: SPDM communication not secure |
Major |
Equipment Unsecure |