Managing the System Time and Date
You can configure the system time and date on your switch manually or automatically by using Network Time Protocol (NTP).
These sections contain this configuration information:
System Clock
The core of the time service is the system clock, which monitors the date and time. This clock starts when the system starts.
The system clock can provide time to these services:
- User show commands
- Logging and debugging messages
The system clock keeps track of time internally based on Universal Time Coordinated (UTC), also known as Greenwich Mean Time (GMT). You can configure information about the local time zone and summer time (daylight saving time) so that the time is correct for the local time zone.
The system clock keeps track of whether the time is authoritative or not (whether it was set by a time source considered to be authoritative). If it is not authoritative, the time is available only for display purposes and is not redistributed. For configuration information, see the “Configuring Time and Date Manually” section.
Understanding Network Time Protocol
The NTP is designed to synchronize a network of devices. NTP runs over User Datagram Protocol (UDP), which runs over IP. NTP is documented in RFC 1305.
An NTP network usually gets its time from an authoritative time source, such as a radio clock or an atomic clock attached to a time server. NTP then distributes this time across the network. NTP is extremely efficient; no more than one packet per minute is necessary to synchronize two devices to within a millisecond of one another.
NTP uses the concept of a stratum to describe how many NTP hops away a device is from an authoritative time source. A stratum 1 time server has a radio or atomic clock directly attached, a stratum 2 time server receives its time through NTP from a stratum 1 time server, and so on. A device running NTP automatically chooses as its time source the device with the lowest stratum number with which it communicates through NTP. This strategy effectively builds a self-organizing tree of NTP speakers.
NTP avoids synchronizing to a device whose time might not have been synchronized. NTP also compares the time reported by several devices and does not synchronize to a device whose time is significantly different than the others, even if its stratum is lower.
The communications between devices running NTP (known as associations) are usually statically configured; each device is given the IP address of all devices with which it should associate. Accurate timekeeping is possible by exchanging NTP messages between each pair of devices with an association. However, in a LAN environment, NTP can be configured to use IP broadcast messages instead. This alternative reduces configuration complexity because each device can be configured to send or receive broadcast messages; however, information flow is one-way only.
The time kept on a device is a critical resource; you should use the security features of NTP to avoid the accidental or malicious setting of an incorrect time. Two mechanisms are available: an access list-based restriction scheme and an encrypted authentication mechanism.
Cisco’s implementation of NTP does not support stratum 1 service; it is not possible to connect to a radio or atomic clock. We recommend that the time service for your network be derived from the public NTP servers available on the IP Internet.
Figure 4-1 shows a typical network example using NTP. Switch A is the NTP master, with Switches B, C, and D configured in NTP server mode, in server association with Switch A. Switch E is configured as an NTP peer to the upstream and downstream switches, Switch B and Switch F, respectively.
Figure 4-1 Typical NTP Network Configuration
If the network is isolated from the Internet, Cisco’s implementation of NTP allows a device to act as if it is synchronized through NTP, when it is not. Other devices then synchronize to that device through NTP.
NTP time overrides the time set by any other method.
Several manufacturers include NTP software for their host systems, and a public version for systems running UNIX and its various derivatives is also available. This software allows host systems to be synchronized as well.
Configuring NTP
These sections contain this configuration information:
Default NTP Configuration
Table 4-1 shows the default NTP configuration.
Table 4-1 Default NTP Configuration
|
|
NTP authentication |
Disabled. No authentication key is specified. |
NTP peer or server associations |
None configured. |
NTP broadcast service |
Disabled; no interface sends or receives NTP broadcast packets. |
NTP access restrictions |
No access control is specified. |
NTP packet source IP address |
The source address is set by the outgoing interface. |
NTP is enabled on all interfaces by default. All interfaces receive NTP packets.
Configuring NTP Authentication
This procedure must be coordinated with the administrator of the NTP server; the information you configure in this procedure must be matched by the servers used by the switch to synchronize its time to the NTP server.
To authenticate the associations (communications between devices running NTP that provide for accurate timekeeping) with other devices for security purposes, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Enables the NTP authentication feature, which is disabled by default. |
Step 3 |
ntp authentication-key
number
md5
value
|
Defines the authentication keys. By default, none are defined.
- For number, specify a key number. The range is 1 to 4294967295.
- md5 specifies that message authentication support is provided by using the message digest algorithm 5 (MD5).
- For value, enter an arbitrary string of up to eight characters for the key.
The switch does not synchronize to a device unless both have one of these authentication keys, and the key number is specified by the ntp trusted-key key-number command. |
Step 4 |
ntp trusted-key
key-number
|
Specifies one or more key numbers (defined in Step 3) that a peer NTP device must provide in its NTP packets for this switch to synchronize to it. By default, no trusted keys are defined. For key-number, specify the key defined in Step 3. This command provides protection against accidentally synchronizing the switch to a device that is not trusted. |
Step 5 |
|
Returns to privileged EXEC mode. |
Step 6 |
|
Verifies your entries. |
Step 7 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
To disable NTP authentication, use the no ntp authenticate global configuration command. To remove an authentication key, use the no ntp authentication-key number global configuration command. To disable authentication of the identity of a device, use the no ntp trusted-key key-number global configuration command.
This example shows how to configure the switch to synchronize only to devices providing authentication key 42 in the device’s NTP packets:
Switch# configure terminal
Switch(config)# ntp authenticate
Switch(config)# ntp authentication-key 42 md5 aNiceKey
Switch(config)# ntp trusted-key 42
Configuring NTP Associations
An NTP association can be a peer association (this switch can either synchronize to the other device or allow the other device to synchronize to it), or it can be a server association (meaning that only this switch synchronizes to the other device, and not the other way around).
To form an NTP association with another device, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
ntp peer
ip-address
[
version
number
] [
key
keyid
] [
source
interface
] [
prefer
]
ntp server
ip-address
[
version
number
] [
key
keyid
] [
source
interface
] [
prefer
]
|
Configures the switch system clock to synchronize a peer or to be synchronized by a peer (peer association). or Configures the switch system clock to be synchronized by a time server (server association). No peer or server associations are defined by default.
- For ip-address in a peer association, specify either the IP address of the peer providing, or being provided, the clock synchronization. For a server association, specify the IP address of the time server providing the clock synchronization.
- (Optional) For number, specify the NTP version number. The range is 1 to 3. By default, Version 3 is selected.
- (Optional) For keyid, enter the authentication key defined by entering the ntp authentication-key global configuration command.
- (Optional) For interface, specify the interface from which to pick the IP source address. By default, the source IP address is taken from the outgoing interface.
- (Optional) Enter the prefer keyword to make this peer or server the preferred one that provides synchronization. This keyword reduces switching back and forth between peers and servers.
|
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
You need to configure only one end of an association; the other device can automatically establish the association. If you are using the default NTP version (Version 3) and NTP synchronization does not occur, try using NTP Version 2. Many NTP servers on the Internet run Version 2.
To remove a peer or server association, use the no ntp peer ip-address or the no ntp server ip-address global configuration command.
This example shows how to configure the switch to synchronize its system clock with the clock of the peer at IP address 172.16.22.44 using NTP Version 2:
Switch# configure terminal
Switch(config)# ntp server 172.16.22.44 version 2
Configuring NTP Broadcast Service
The communications between devices running NTP (known as associations) are usually statically configured; each device is given the IP addresses of all devices with which it should form associations. Accurate timekeeping is possible by exchanging NTP messages between each pair of devices with an association. However, in a LAN environment, NTP can be configured to use IP broadcast messages instead. This alternative reduces configuration complexity because each device can be configured to send or receive broadcast messages. However, the information flow is one-way only.
The switch can send or receive NTP broadcast packets on an interface-by-interface basis if there is an NTP broadcast server, such as a router, broadcasting time information on the network. The switch can send NTP broadcast packets to a peer so that the peer can synchronize to it. The switch can also receive NTP broadcast packets to synchronize its own clock. This section provides procedures for both sending and receiving NTP broadcast packets.
To configure the switch to send NTP broadcast packets to peers so that they can synchronize their clock to the switch, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Specifies the interface to send NTP broadcast packets, and enter interface configuration mode. |
Step 3 |
ntp broadcast
[
version
number
] [
key
keyid
] [
destination-address
]
|
Enables the interface to send NTP broadcast packets to a peer. By default, this feature is disabled on all interfaces.
- (Optional) For number, specify the NTP version number. The range is 1 to 3. If you do not specify a version, Version 3 is used.
- (Optional) For keyid, specify the authentication key to use when sending packets to the peer.
- (Optional) For destination-address, specify the IP address of the peer that is synchronizing its clock to this switch.
|
Step 4 |
|
Returns to privileged EXEC mode. |
Step 5 |
|
Verifies your entries. |
Step 6 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
To disable the interface from sending NTP broadcast packets, use the no ntp broadcast interface configuration command.
This example shows how to configure a port to send NTP Version 2 packets:
Switch# configure terminal
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# ntp broadcast version 2
To configure the switch to receive NTP broadcast packets from connected peers, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Specifies the interface to receive NTP broadcast packets, and enter interface configuration mode. |
Step 3 |
|
Enables the interface to receive NTP broadcast packets. By default, no interfaces receive NTP broadcast packets. |
Step 4 |
|
Returns to global configuration mode. |
Step 5 |
ntp broadcastdelay
microseconds
|
(Optional) Changes the estimated round-trip delay between the switch and the NTP broadcast server. The default is 3000 microseconds; the range is 1 to 999999. |
Step 6 |
|
Returns to privileged EXEC mode. |
Step 7 |
|
Verifies your entries. |
Step 8 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
To disable an interface from receiving NTP broadcast packets, use the no ntp broadcast client interface configuration command. To change the estimated round-trip delay to the default, use the
no ntp broadcastdelay global configuration command.
This example shows how to configure a port to receive NTP broadcast packets:
Switch# configure terminal
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# ntp broadcast client
Configuring NTP Access Restrictions
You can control NTP access on two levels as described in these sections:
Creating an Access Group and Assigning a Basic IP Access List
To control access to NTP services by using access lists, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
ntp access-group
{
query-only
|
serve-onl
y |
serve
|
peer
}
access-list-number
|
Creates an access group, and apply a basic IP access list. The keywords have these meanings:
- query-only —Allows only NTP control queries.
- serve-only —Allows only time requests.
- serve —Allows time requests and NTP control queries, but does not allow the switch to synchronize to the remote device.
- peer —Allows time requests and NTP control queries and allows the switch to synchronize to the remote device.
For access-list-number, enter a standard IP access list number from 1 to 99. |
Step 3 |
access-list
access-list-number
permit
source
[
source-wildcard
]
|
Creates the access list.
- For access-list-number, enter the number specified in Step 2.
- Enter the permit keyword to permit access if the conditions are matched.
- For source, enter the IP address of the device that is permitted access to the switch.
- (Optional) For source-wildcard, enter the wildcard bits to be applied to the source.
Note When creating an access list, remember that, by default, the end of the access list contains an implicit deny statement for everything if it did not find a match before reaching the end. |
Step 4 |
|
Returns to privileged EXEC mode. |
Step 5 |
|
Verifies your entries. |
Step 6 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
The access group keywords are scanned in this order, from least restrictive to most restrictive:
1. peer —Allows time requests and NTP control queries and allows the switch to synchronize itself to a device whose address passes the access list criteria.
2. serve —Allows time requests and NTP control queries, but does not allow the switch to synchronize itself to a device whose address passes the access list criteria.
3. serve-only —Allows only time requests from a device whose address passes the access list criteria.
4. query-only —Allows only NTP control queries from a device whose address passes the access list criteria.
If the source IP address matches the access lists for more than one access type, the first type is granted. If no access groups are specified, all access types are granted to all devices. If any access groups are specified, only the specified access types are granted.
To remove access control to the switch NTP services, use the
no ntp access-group { query-only | serve-only | serve | peer } global configuration command.
This example shows how to configure the switch to allow itself to synchronize to a peer from access list 99. However, the switch restricts access to allow only time requests from access list 42:
Switch# configure terminal
Switch(config)# ntp access-group peer 99
Switch(config)# ntp access-group serve-only 42
Switch(config)# access-list 99 permit 172.20.130.5
Switch(config)# access list 42 permit 172.20.130.6
Disabling NTP Services on a Specific Interface
NTP services are enabled on all interfaces by default.
To disable NTP packets from being received on an interface, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Enters interface configuration mode, and specify the interface to disable. |
Step 3 |
|
Disables NTP packets from being received on the interface. By default, all interfaces receive NTP packets. To reenable receipt of NTP packets on an interface, use the no ntp disable interface configuration command. |
Step 4 |
|
Returns to privileged EXEC mode. |
Step 5 |
|
Verifies your entries. |
Step 6 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
Configuring the Source IP Address for NTP Packets
When the switch sends an NTP packet, the source IP address is normally set to the address of the interface through which the NTP packet is sent. To use a particular source IP address for all NTP packets, use the ntp source global configuration command. The address is taken from the specified interface. This command is useful if the address on an interface cannot be used as the destination for reply packets.
To configure a specific interface from which the IP source address is to be taken, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Specifies the interface type and number from which the IP source address is taken. By default, the source address is set by the outgoing interface. |
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
The specified interface is used for the source address for all packets sent to all destinations. If a source address is to be used for a specific association, use the source keyword in the ntp peer or n tp server global configuration command as described in the “Configuring NTP Associations” section.
Displaying the NTP Configuration
Use the following privileged EXEC commands to display NTP information:
- show ntp associations [ detail ]
- show ntp status
For detailed information about the fields in these displays, see the
Cisco IOS Configuration Fundamentals Command Reference, Release 12.3.
Configuring Time and Date Manually
If no other source of time is available, you can manually configure the time and date after the system is restarted. The time remains accurate until the next system restart. We recommend that you use manual configuration only as a last resort. If you have an outside source to which the switch can synchronize, you do not need to manually set the system clock.
These sections contain this configuration information:
Setting the System Clock
If you have an outside source on the network that provides time services, such as an NTP server, you do not need to manually set the system clock.
To set the system clock, perform this task:
|
|
|
Step 1 |
clock set
hh
:
mm
:
ss
day
month
year
clock set
hh
:
mm
:
ss
month day year
|
Manually sets the system clock using one of these formats.
- For hh : mm : ss, specify the time in hours (24-hour format), minutes, and seconds. The time specified is relative to the configured time zone.
- For day, specify the day by date in the month.
- For month, specify the month by name.
- For year, specify the year (no abbreviation).
|
This example shows how to manually set the system clock to 1:32 p.m. on July 23, 2001:
Switch# clock set 13:32:00 23 July 2001
Displaying the Time and Date Configuration
To display the time and date configuration, use the show clock [ detail ] privileged EXEC command.
The system clock keeps an authoritative flag that shows whether the time is authoritative (believed to be accurate). If the system clock was set by a timing source such as NTP, the flag is set. If the time is not authoritative, it is used only for display purposes. Until the clock is authoritative and the authoritative flag is set, the flag prevents peers from synchronizing to the clock when the peers’ time is invalid.
The symbol that precedes the show clock display has this meaning:
- *—Time is not authoritative.
- (blank)—Time is authoritative.
- .—Time is authoritative, but NTP is not synchronized.
Configuring the Time Zone
To manually configure the time zone, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
clock timezone
zone
hours-offset
[
minutes-offset
]
|
Sets the time zone. To set the time to UTC, use the no clock timezone global configuration command. The switch keeps internal time in universal time coordinated (UTC), so this command is used only for display purposes and when the time is manually set.
- For zone, enter the name of the time zone to be displayed when standard time is in effect. The default is UTC.
- For hours-offset, enter the hours offset from UTC.
- (Optional) For minutes-offset, enter the minutes offset from UTC.
|
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
The minutes-offset variable in the clock timezone global configuration command is available for those cases where a local time zone is a percentage of an hour different from UTC. For example, the time zone for some sections of Atlantic Canada (AST) is UTC-3.5, where the 3 means 3 hours and.5 means 50 percent. The necessary command is clock timezone AST -3 30.
Configuring Summer Time (Daylight Saving Time)
To configure summer time (daylight saving time) in areas where it starts and ends on a particular day of the week each year, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
clock summer-time
zone
recurring
[
week day month hh
:
mm week day month hh
:
mm
[
offset
]]
|
Configures summer time to start and end on the specified days every year. Summer time is disabled by default. If you specify clock summer-time zone recurring without parameters, the summer time rules default to the United States rules.
- For zone, specify the name of the time zone (for example, PDT) to be displayed when summer time is in effect.
- (Optional) For week, specify the week of the month (1 to 5 or last).
- (Optional) For day, specify the day of the week (Sunday, Monday...).
- (Optional) For month, specify the month (January, February...).
- (Optional) For hh : mm, specify the time (24-hour format) in hours and minutes.
- (Optional) For offset, specify the number of minutes to add during summer time. The default is 60.
|
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
The first part of the clock summer-time global configuration command specifies when summer time begins, and the second part specifies when it ends. All times are relative to the local time zone. The start time is relative to standard time. The end time is relative to summer time. If the starting month is after the ending month, the system assumes that you are in the southern hemisphere.
This example shows how to specify that summer time starts on the first Sunday in April at 02:00 and ends on the last Sunday in October at 02:00:
Switch# configure terminal
Switch(config)# clock summer-time PDT recurring 1 Sunday April 2:00 last Sunday October 2:00
If summer time in your area does not follow a recurring pattern (configure the exact date and time of the next summer time events), perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
clock summer-time
zone
date
[
month date year hh
:
mm month date year hh
:
mm
[
offset
]]
clock summer-time
zone
date
[
date
month year hh
:
mm date month year hh
:
mm
[
offset
]]
|
Configures summer time to start on the first date and end on the second date. To disable summer time, use the no clock summer-time global configuration command. Summer time is disabled by default.
- For zone, specify the name of the time zone (for example, PDT) to be displayed when summer time is in effect.
- (Optional) For week, specify the week of the month (1 to 5 or last).
- (Optional) For day, specify the day of the week (Sunday, Monday...).
- (Optional) For month, specify the month (January, February...).
- (Optional) For hh : mm, specify the time (24-hour format) in hours and minutes.
- (Optional) For offset, specify the number of minutes to add during summer time. The default is 60.
|
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
The first part of the clock summer-time global configuration command specifies when summer time begins, and the second part specifies when it ends. All times are relative to the local time zone. The start time is relative to standard time. The end time is relative to summer time. If the starting month is after the ending month, the system assumes that you are in the southern hemisphere.
To disable summer time, use the no clock summer-time global configuration command.
This example shows how to set summer time to start on October 12, 2000, at 02:00, and end on April 26, 2001, at 02:00:
Switch# configure terminal
Switch(config)# clock summer-time pdt date 12 October 2000 2:00 26 April 2001 2:00
Configuring a System Name and Prompt
You configure the system name on the switch to identify it. By default, the system name and prompt are Switch.
If you have not configured a system prompt, the first 20 characters of the system name are used as the system prompt. A greater-than symbol [>] is appended. The prompt is updated whenever the system name changes.
For complete syntax and usage information for the commands used in this section, see the Cisco IOS Configuration Fundamentals Command Reference, Release 12.3 and the Cisco IOS IP Command Reference, Volume 2 of 3: Routing Protocols, Release 12.3.
These sections contain this configuration information:
Configuring a System Name
To manually configure a system name, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Manually configures a system name. The default setting is switch. The name must follow the rules for ARPANET hostnames. They must start with a letter, end with a letter or digit, and have as interior characters only letters, digits, and hyphens. Names can be up to 63 characters. To return to the default hostname, use the no hostname global configuration command. |
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
|
Verifies your entries. |
Step 5 |
copy running-config startup-confi g
|
(Optional) Saves your entries in the configuration file. |
When you set the system name, it is also used as the system prompt.
Understanding DNS
The DNS protocol controls the Domain Name System (DNS), a distributed database with which you can map hostnames to IP addresses. When you configure DNS on your switch, you can substitute the hostname for the IP address with all IP commands, such as ping, telnet, connect, and related Telnet support operations.
IP defines a hierarchical naming scheme that allows a device to be identified by its location or domain. Domain names are pieced together with periods (.) as the delimiting characters. For example, Cisco Systems is a commercial organization that IP identifies by a com domain name, so its domain name is cisco.com. A specific device in this domain, for example, the File Transfer Protocol (FTP) system is identified as ftp.cisco.com.
To keep track of domain names, IP has defined the concept of a domain name server, which holds a cache (or database) of names mapped to IP addresses. To map domain names to IP addresses, you must first identify the hostnames, specify the name server that is present on your network, and enable the DNS.
These sections contain this configuration information:
Default DNS Configuration
Table 4-2 shows the default DNS configuration.
Table 4-2 Default DNS Configuration
|
|
DNS enable state |
Enabled. |
DNS default domain name |
None configured. |
DNS servers |
No name server addresses are configured. |
Setting Up DNS
To set up your switch to use the DNS, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
|
Defines a default domain name that the software uses to complete unqualified hostnames (names without a dotted-decimal domain name). To remove a domain name, use the no ip domain-name name global configuration command. Do not include the initial period that separates an unqualified name from the domain name. At boot time, no domain name is configured; however, if the switch configuration comes from a BOOTP or Dynamic Host Configuration Protocol (DHCP) server, then the default domain name might be set by the BOOTP or DHCP server (if the servers were configured with this information). |
Step 3 |
ip name-server
server-address1
[
server-address2... server-address6
]
|
Specifies the address of one or more name servers to use for name and address resolution. To remove a name server address, use the no ip name-server server-address global configuration command. You can specify up to six name servers. Separate each server address with a space. The first server specified is the primary server. The switch sends DNS queries to the primary server first. If that query fails, the backup servers are queried. |
Step 4 |
|
(Optional) Enables DNS-based hostname-to-address translation on your switch. This feature is enabled by default. To disable DNS on the switch, use the no ip domain-lookup global configuration command. If your network devices require connectivity with devices in networks for which you do not control name assignment, you can dynamically assign device names that uniquely identify your devices by using the global Internet naming scheme (DNS). |
Step 5 |
|
Returns to privileged EXEC mode. |
Step 6 |
|
Verifies your entries. |
Step 7 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
If you use the switch IP address as its hostname, the IP address is used and no DNS query occurs. If you configure a hostname that contains no periods (.), a period followed by the default domain name is appended to the hostname before the DNS query is made to map the name to an IP address. The default domain name is the value set by the ip domain-name global configuration command. If there is a period (.) in the hostname, the Cisco IOS software looks up the IP address without appending any default domain name to the hostname.
Displaying the DNS Configuration
To display the DNS configuration information, use the show running-config privileged EXEC command.
Managing the MAC Address Table
The MAC address table contains address information that the switch uses to forward traffic between ports. All MAC addresses in the address table are associated with one or more ports. The address table includes these types of addresses:
- Dynamic address—A source MAC address that the switch learns and then ages when it is not in use.
- Static address—A manually entered unicast address that does not age and that is not lost when the switch resets.
The address table lists the destination MAC address, the associated VLAN ID, and port number associated with the address and the type (static or dynamic).
Note For complete syntax and usage information for the commands used in this section, see the command reference for this release.
These sections contain this configuration information:
Building the Address Table
With multiple MAC addresses supported on all ports, you can connect any port on the switch to individual workstations, repeaters, switches, routers, or other network devices. The switch provides dynamic addressing by learning the source address of packets it receives on each port and adding the address and its associated port number to the address table. As stations are added or removed from the network, the switch updates the address table, adding new dynamic addresses and aging out those that are not in use.
The aging interval is globally configured. However, the switch maintains an address table for each VLAN, and STP can accelerate the aging interval on a per-VLAN basis.
The switch sends packets between any combination of ports, based on the destination address of the received packet. Using the MAC address table, the switch forwards the packet only to the port associated with the destination address. If the destination address is on the port that sent the packet, the packet is filtered and not forwarded. The switch always uses the store-and-forward method: complete packets are stored and checked for errors before transmission.
MAC Addresses and VLANs
All addresses are associated with a VLAN. An address can exist in more than one VLAN and have different destinations in each. Unicast addresses, for example, could be forwarded to port 1 in VLAN 1 and ports 9, 10, and 1 in VLAN 5.
Each VLAN maintains its own logical address table. A known address in one VLAN is unknown in another until it is learned or statically associated with a port in the other VLAN.
When PVLANs are configured, address learning depends on the type of MAC address:
- Dynamic MAC addresses learned in one VLAN of a PVLAN are replicated in the associated VLANs. For example, a MAC address learned in a private-VLAN secondary VLAN is replicated in the primary VLAN.
- Static MAC addresses configured in a primary or secondary VLAN are not replicated in the associated VLANs. When you configure a static MAC address in a PVLAN primary or secondary VLAN, you should also configure the same static MAC address in all associated VLANs.
For more information about PVLANs, see Chapter39, “Configuring Private VLANs”
Default MAC Address Table Configuration
Table 4-3 shows the default MAC address table configuration.
Table 4-3 Default MAC Address Table Configuration
|
|
Aging time |
300 seconds |
Dynamic addresses |
Automatically learned |
Static addresses |
None configured |
Changing the Address Aging Time
Dynamic addresses are source MAC addresses that the switch learns and then ages when they are not in use. You can change the aging time setting for all VLANs or for a specified VLAN.
Setting too short an aging time can cause addresses to be prematurely removed from the table. When the switch receives a packet for an unknown destination, it floods the packet to all ports in the same VLAN as the receiving port. This unnecessary flooding can impact performance. Setting too long an aging time can cause the address table to be filled with unused addresses, which prevents new addresses from being learned. Flooding results, which can impact switch performance.
To configure the dynamic address table aging time, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
mac address-table aging-time
[
0
|
10-1000000
] [
vlan
vlan-id
]
|
Sets the length of time that a dynamic entry remains in the MAC address table after the entry is used or updated. To return to the default value, use the no mac address-table aging-time global configuration command. The range is 10 to 1000000 seconds. The default is 300. You can also enter 0, which disables aging. Static address entries are never aged or removed from the table. For vlan-id, valid IDs are 1 to 4094. |
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
show mac address-table aging-time
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
Removing Dynamic Address Entries
To remove all dynamic entries, use the clear mac address-table dynamic command in EXEC mode. You can also remove a specific MAC address (clear mac address-table dynamic address mac-address), remove all addresses on the specified physical port or port channel
(clear mac address-table dynamic interface interface-id), or remove all addresses on a specified VLAN (clear mac address-table dynamic vlan vlan-id).
To verify that dynamic entries have been removed, use the show mac address-table dynamic privileged EXEC command.
Configuring MAC Change Notification Traps
MAC change notification allows you to track users on a network by storing the MAC change activity on the switch. Whenever the switch learns or removes a MAC address, an SNMP notification can be generated and sent to the network management system. If you have many users entering and exiting the network, you can set a trap interval time to bundle the notification traps and reduce network traffic. The MAC notification history table stores the MAC address activity for each hardware port for which the trap is enabled. MAC address notifications are generated for dynamic and static MAC addresses; events are not generated for self addresses or multicast addresses.
To send MAC change notification traps to an NMS host, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
snmp-server host
host-addr
[
traps
|
informs
] {
version
{
1
|
2c
|
3
}} [
auth
|
noauth
|
priv
]
community-string [udp-port port] [notification-type]
|
Specifies the recipient of the trap message.
- For host-addr, specify the name or address of the NMS.
- Specify traps (the default) to send SNMP traps to the host. Specify informs to send SNMP informs to the host.
- Specify the SNMP version to support. Version 1, the default, is not available with informs.
- For community-string, specify the string to send with the notification operation. Though you can set this string by using the snmp-server host command, we recommend that you define this string by using the snmp-server community command before using the snmp-server host command.
- For notification-type, use the mac-notification keyword.
|
Step 3 |
snmp-server enable traps mac-notification change
|
Enables the switch to send MAC change traps to the NMS. To disable the switch from sending MAC change notification traps, use the no snmp-server enable traps mac-notification change global configuration command. |
Step 4 |
mac address-table notification change
|
Enables the MAC address change notification feature. |
Step 5 |
mac address-table notification change
[
interval
value
] | [
history-size
value
]
|
Enters the trap interval time and the history table size.
- (Optional) For interval value, specify the notification trap interval in seconds between each set of traps that are generated to the NMS. The range is 0 to 2147483647 seconds; the default is 1 second.
- (Optional) For history-size value, specify the maximum number of entries in the MAC notification history table. The range is 0 to 500; the default is 1.
To disable the MAC change notification feature, use the no mac address-table notification change global configuration command. |
Step 6 |
|
Enters interface configuration mode, and specifies the interface on which to enable the SNMP MAC change notification trap. |
Step 7 |
snmp trap mac-notification change
{
added
|
removed
}
|
Enables the MAC change notification trap.
- Enable the MAC change notification trap whenever a MAC address is added on this interface.
- Enable the MAC change notification trap whenever a MAC address is removed from this interface.
To disable the MAC change notification traps on a specific interface, use the no snmp trap mac-notification change { added | removed } interface configuration command. |
Step 8 |
|
Returns to privileged EXEC mode. |
Step 9 |
show mac address-table notification change interface
|
Verifies your entries. |
Step 10 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
This example shows how to specify 172.69.59.93 as the network management system, enable the switch to send MAC change notification traps to the network management system, enable the MAC change notification feature, set the interval time to 60 seconds, set the history-size to 100 entries, and enable traps whenever a MAC address is added on the specified port:
Switch# configure terminal
Switch(config)# snmp-server host 172.69.59.93 private mac-notification
Switch(config)# snmp-server enable traps mac-notification change
Switch(config)# mac address-table notification change
Switch(config)# mac address-table notification change interval 60
Switch(config)# mac address-table notification change history-size 100
Switch(config)# interface fastethernet0/2
Switch(config-if)# snmp trap mac-notification change added
Switch# show mac address-table notification change interface
MAC Notification Feature is Enabled on the switch
MAC Notification Flags For All Ethernet Interfaces :
----------------------------------------------------
Interface MAC Added Trap MAC Removed Trap
--------- -------------- ----------------
GigabitEthernet1/1 Enabled Enabled
GigabitEthernet1/2 Enabled Enabled
GigabitEthernet1/3 Enabled Enabled
GigabitEthernet1/4 Enabled Enabled
GigabitEthernet1/5 Enabled Enabled
GigabitEthernet1/6 Enabled Enabled
GigabitEthernet1/7 Enabled Enabled
GigabitEthernet1/8 Enabled Enabled
GigabitEthernet1/9 Enabled Enabled
GigabitEthernet1/10 Enabled Enabled
GigabitEthernet1/11 Enabled Enabled
GigabitEthernet1/12 Enabled Enabled
Configuring MAC Move Notification Traps
When you configure MAC move notification, an SNMP notification is generated and sent to the network management system whenever a MAC address moves from one port to another within the same VLAN.
To configure MAC move notification, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
snmp-server host
host-addr
[
traps
|
informs
] {
version
{
1
|
2c
|
3
}} [
auth
|
noauth
|
priv
]
community-string [udp-port port] [notification-type]
|
Specifies the recipient of the trap message.
- For host-addr, specify the name or address of the NMS.
- Specify traps (the default) to send SNMP traps to the host. Specify informs to send SNMP informs to the host.
- Specify the SNMP version to support. Version 1, the default, is not available with informs.
- For community-string, specify the string to send with the notification operation. Though you can set this string by using the snmp-server host command, we recommend that you define this string by using the snmp-server community command before using the snmp-server host command.
- For notification-type, use the mac-notification keyword.
|
Step 3 |
snmp-server enable traps mac-notification move
|
Enables the switch to send MAC move notification traps to the NMS. To disable the switch from sending MAC notification traps, use the no snmp-server enable traps mac-notification move global configuration command. |
Step 4 |
mac address-table notification mac-move
|
Enables the MAC-move notification feature. To disable this feature, use the no mac-address-table notification mac-move global configuration command. |
Step 5 |
|
Returns to privileged EXEC mode. |
Step 6 |
show mac address-table notification mac-move
|
Displays the MAC-move notification status. |
Step 7 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
This example shows how to specify 172.69.59.93 as the network management system, enable the switch to send MAC move notification traps to the NMS, enable the MAC move notification feature, and enable traps whenever a MAC address moves from one port to another:
Switch# configure terminal
Switch(config)# snmp-server host 171.69.59.93 private mac-notification
Switch(config)# snmp-server enable traps mac-notification move
Switch(config)# mac address-table notification mac-move
Switch# show mac address-table notification mac-move
MAC Move Notification: Enabled
Configuring MAC Threshold Notification Traps
When you configure MAC threshold notification, an SNMP notification is generated and sent to the network management system when a MAC address table (MAT) threshold limit is reached or exceeded.
To configure MAC address threshold notification, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
snmp-server host
host-addr
[
traps
|
informs
] {
version
{
1
|
2c
|
3
}} [
auth
|
noauth
|
priv
]
community-string [udp-port port] [notification-type]
|
Specifies the recipient of the trap message.
- For host-addr, specify the name or address of the NMS.
- Specify traps (the default) to send SNMP traps to the host. Specify informs to send SNMP informs to the host.
- Specify the SNMP version to support. Version 1, the default, is not available with informs.
- For community-string, specify the string to send with the notification operation. Though you can set this string by using the snmp-server host command, we recommend that you define this string by using the snmp-server community command before using the snmp-server host command.
- For notification-type, use the mac-notification keyword.
|
Step 3 |
snmp-server enable traps mac-notification threshold
|
Enables the switch to send MAC threshold notification traps to the NMS. To disable the switch from sending MAC threshold notification traps, use the no snmp-server enable traps mac-notification threshold global configuration command. |
Step 4 |
mac address-table notification threshold
|
Enables the MAC address threshold notification feature. To disable this feature, use the no address-table notification threshold global configuration command. |
Step 5 |
mac address-table notification threshold
[
limit
percentage
] | [
interval
time
]
|
Enters the threshold value for the MAT usage monitoring.
- (Optional) For limit percentage, specify the percentage of the MAT utilization; valid values are from 1 to 100 percent. Default is 50 percent.
- (Optional) For interval time, specify the time between notifications; valid values are greater than or equal to 120 seconds. Default is 120 seconds.
|
Step 6 |
|
Returns to privileged EXEC mode. |
Step 7 |
show mac address-table notification threshold
|
Displays the MAC utilization threshold notification status. |
Step 8 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
This example shows how to specify 172.69.59.93 as the network management system, enable the MAC threshold notification feature, enable the switch to send MAC threshold notification traps to the NMS, set the interval to 123 seconds, and set the limit to 78 percent:
Switch# configure terminal
Switch(config)# snmp-server host 171.69.59.93 private mac-notification
Switch(config)# snmp-server enable traps mac-notification threshold
Switch(config)# mac address-table notification threshold
Switch(config)# mac address-table notification threshold interval 123
Switch(config)# mac address-table notification threshold limit 78
Switch# show mac-address-table notification threshold
-------------+-----------+-------------
Adding and Removing Static Address Entries
A static address has these characteristics:
- It is manually entered in the address table and must be manually removed.
- It can be a unicast or multicast address.
- It does not age and is retained when the switch restarts.
You can add and remove static addresses and define the forwarding behavior for them. The forwarding behavior defines how a port that receives a packet forwards it to another port for transmission. Because all ports are associated with at least one VLAN, the switch acquires the VLAN ID for the address from the ports that you specify. You can specify a different list of destination ports for each source port.
A packet with a static address that arrives on a VLAN where it has not been statically entered is flooded to all ports and not learned.
You add a static address to the address table by specifying the destination MAC unicast address and the VLAN from which it is received. Packets received with this destination address are forwarded to the interface specified with the interface-id option.
When you configure a static MAC address in a private-VLAN primary or secondary VLAN, you should also configure the same static MAC address in all associated VLANs. Static MAC addresses configured in a private-VLAN primary or secondary VLAN are not replicated in the associated VLAN. For more information about PVLANs, see Chapter39, “Configuring Private VLANs”
To add a static address, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
mac address-table static
mac-addr
vlan
vlan-id
interface
interface-id
|
Adds a static address to the MAC address table.
- For mac-addr, specify the destination MAC unicast address to add to the address table. Packets with this destination address received in the specified VLAN are forwarded to the specified interface.
- For vlan-id, specify the VLAN for which the packet with the specified MAC address is received. Valid VLAN IDs are 1 to 4094.
- For interface-id, specify the interface to which the received packet is forwarded. Valid interfaces include physical ports or port channels.
You can specify static multicast addresses for multiple interface IDs. However, you cannot assign static unicast MAC address to multiple interfaces with the same MAC address and VLAN ID. To remove static entries from the address table, use the no mac address-table static mac-addr vlan vlan-id [ interface interface-id ] global configuration command. |
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
show mac address-table static
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
This example shows how to add the static address c2f3.220a.12f4 to the MAC address table. When a packet is received in VLAN 4 with this MAC address as its destination address, the packet is forwarded to the specified port:
Switch# configure terminal
Switch(config)# mac address-table static c2f3.220a.12f4 vlan 4 interface gigabitethernet0/1
Configuring Unicast MAC Address Filtering
When unicast MAC address filtering is enabled, the switch drops packets with specific source or destination MAC addresses. This feature is disabled by default and only supports unicast static addresses.
When using unicast address filtering, consider these guidelines:
- Multicast MAC addresses, broadcast MAC addresses, and router MAC addresses are not supported. If you specify one of these addresses when entering the mac address-table static vlan drop global configuration command, one of these messages appears:
% Only unicast addresses can be configured to be dropped
% CPU destined address cannot be configured as drop address
- Packets that are forwarded to the CPU are also not supported.
- If you add a unicast MAC address as a static address and configure unicast MAC address filtering, the switch either adds the MAC address as a static address or drops packets with that MAC address, depending on which command was entered last. The second command that you entered overrides the first command.
For example, if you enter the mac address-table static vlan interface global configuration command followed by the mac address-table static vlan drop command, the switch drops packets with the specified MAC address as a source or destination.
If you enter the mac address-table static vlan drop global configuration command followed by the mac address-table static vlan interface command, the switch adds the MAC address as a static address.
You enable unicast MAC address filtering and configure the switch to drop packets with a specific address by specifying the source or destination unicast MAC address and the VLAN from which it is received.
To configure the switch to drop a source or destination unicast static address, perform this task:
|
|
|
Step 1 |
|
Enters global configuration mode. |
Step 2 |
mac address-table static
mac-addr
vlan
vlan-id
drop
|
Enables unicast MAC address filtering and configure the switch to drop a packet with the specified source or destination unicast static address.
- For mac-addr, specify a source or destination unicast MAC address. Packets with this MAC address are dropped.
- For vlan-id, specify the VLAN for which the packet with the specified MAC address is received. Valid VLAN IDs are 1 to 4094.
To disable unicast MAC address filtering, use the no mac address -table static vlan global configuration command. |
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
show mac address-table static
|
Verifies your entries. |
Step 5 |
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
This example shows how to enable unicast MAC address filtering and to configure the switch to drop packets that have a source or destination address of c2f3.220a.12f4. When a packet is received in VLAN 4 with this MAC address as its source or destination, the packet is dropped:
Switch# configure terminal
Switch(config)# mac address-table static c2f3.220a.12f4 vlan 4 drop
Note To filter MAC addresses on a secondary VLAN, specify the corresponding primary VLAN in the above configuration. If the specified VLAN is a primary VLAN, all matching packets received in this primary VLAN and associated secondary VLANs are dropped.
Disabling MAC Address Learning on a VLAN
By default, MAC address learning is enabled on all VLANs on the switch. By controlling which VLANs can learn MAC addresses, you can manage the available MAC address table space. By disabling learning on a VLAN, you can conserve the MAC address table space because all the MAC addresses seen on this VLAN are not learned.
Before disabling MAC address learning, you should understand the network topology and features deployed. Many Layer 2 features use MAC addresses and may not work properly if learning is disabled. Because disabling learning causes flooding of packets, you need to understand the impact of flooding on the network.
These sections contain this information:
Configuring Disable MAC Address Learning
To disable MAC address learning on a VLAN, perform this task:
|
|
|
Step 1 |
Switch#
configure terminal
|
Enters global configuration mode. |
Step 2 |
Switch(config)#
no mac address-table learning vlan
vlan-id range
|
Disables MAC address learning on the specified VLAN or VLANs. You can specify a single VLAN ID or a range of VLAN IDs separated by a hyphen or comma. Valid VLAN IDs are 1 to 4094. You can reenable MAC address learning on a VLAN by entering the mac address-table learning vlan global configuration command. |
Step 3 |
|
Returns to privileged EXEC mode. |
Step 4 |
Switch#
show mac address-table learning [
vlan
vlan-id range ]
|
Displays the MAC address learning status of all VLANs or a specified VLAN. |
Step 5 |
Switch#
copy running-config startup-config
|
(Optional) Saves your entries in the configuration file. |
This example shows how to disable learning on any VLAN or range of VLANs:
Switch# configure terminal
Switch(config)# no mac address-table learning vlan 9-16
Switch# show mac address-table learning
Learning disabled on vlans: 9-11,13-16
Switch# show mac address-table learning vlan 10-15
Learning disabled on vlans: 10-11,13-15
Usage Guidelines
Note These guidelines are advisory only. Contact the Cisco solution provider team for specific solution implementations.
When disabling MAC address learning on a VLAN, consider these guidelines:
- If learning is disabled on a VLAN with an SVI interface, it floods every IP packet in the Layer 2 domain. Because this flooding may be undesirable, you should disable MAC address learning on a SVI VLAN carefully.
- If you provide a VLAN range that includes reserved VLAN (such as 1000-1006), the command is accepted and disable learning is enabled for all VLANs except for 1002-005 (that is, 1000-1001,1006). However, if you specify an invalid range (such as 1-5000), the command fails and disable learning is not enabled on any of the VLANs.
- With PVLANs, you need to disable learning on the primary VLAN and all secondary VLANs associated with that primary VLANs. Otherwise, you encounter traffic flooding in one direction and unicast flooding in the other direction.
- To disable MAC address learning on a VLAN, consider the flooding implications.
Deployment Scenarios
This section includes these deployment scenarios:
Metro (Point to Point Links)
In this topology, you have two ports on a VLAN; traffic enters one and must exit the other. On a point-to-point link in metro networks, numerous MAC addresses are on these types of ports by disabling learning on the VLAN to which these two ports belong, many entries in the MAC address table space can be saved. Because there is only one egress port for the traffic, you can flood the packet and avoid having to learn all the MAC addresses seen on this port. This process saves considerable space in the MAC address table.
To obtain source learning, packets are bridged as Layer 2 flood packets. Replicated packets use a distinct dedicated bandwidth. Regardless of the number of ports in a flood set, a flood packet always consumes replication packet bandwidth, which consumes some multicast and broadcast packet-processing bandwidth (Figure 4-2).
Figure 4-2 Disabling MAC Address Learning: Point-to-Point Links
Network Load Balancers
In this topology, you have two devices, one active and one standby. To perform load balancing, both devices must receive all packets. You could place both devices on the same VLAN. If learning can be disabled on this VLAN, the packet is flooded and both devices receive all traffic destined to any MAC address on the VLAN. You also can assign a multicast MAC address to both load balancers to ensure that all packets reach them. (Figure 4-3).
Figure 4-3 Disabling MAC Address Learning: Network Load Balancers
Layer 2 Firewall or Cache
In this topology, a rewritten Layer 3 packet is routed back to a Layer 2 firewall (or cache) before exiting. When the packet reenters the switch from the firewall, it possesses the switch’s MAC address because the packet was previously routed. If the ingress port is a switch port, the switch learns the router’s MAC address. For a routed port or SVI, however, the switch does not learn the address. Source misses are generated continuously for all arriving data packets and the switch shows a very high CPU utilization.
By disabling learning on the VLAN that the firewall or cache egress is connected to, you will routinely suppress the source miss and do not observe high CPU utilization (Figure 4-4).
Figure 4-4 Disabling MAC Address Learning: Layer 2 Firewall/Cache
Feature Compatibility
The following features are compatible with disabling MAC address learning on a VLAN:
- EtherChannel—The learning disable feature has no impact on EtherChannel provided that the MAC learning state is either disabled or enabled for a VLAN on EtherChannel ports.
- Switch Virtual Interface (SVI, Layer 3 on a VLAN)— The learning disable feature has no impact on SVI. Although disabling MAC address learning on a SVI VLAN causes flooding, it does not impact any Layer 3 feature.
- REP—The learning disable feature has no impact on REP provided that the MAC learning state is either disabled or enabled for an active VLAN on a port where REP is running.
- Unicast, Multicast, and Broadcast—When you enable learning on a VLAN, learning is disabled on all types of traffic.
- DAI, ESMP, and IGMP snooping— These features do not interact with the learning disable feature.
- Control packets— Control packets arrive at the CPU even if learning is disabled.
- RSPAN— Learning on a VLAN and on an RSPAN are compatible.
- VLAN translation—To disable learning on a VLAN that is being translated, you must disable learning on the translated VLAN.
Feature Incompatibility
The following features are incompatible with disabling MAC address learning and do not work properly when the feature is enabled:
- 802.1X—The 802.1X class of features does not work when learning is disabled because some of these features require source miss, which is ignored.
- Port security— Port security VLANs requires learning to be enabled. To secure MAC addresses, packets must first arrive at the CPU. However, if you disable learning on a VLAN, SA suppression ensures that packets do not operate this way.
- Unicast flood blocking— When unicast flood blocking is enabled on a port, it is removed from the VLAN flood set. If learning is disabled on the same VLAN, the host connected to that port do not receive traffic.
- DHCP snooping—To send the packet out the correct port once a DHCP request has been resolved, DHCP snooping must learn the MAC address. If you disable learning, the switch do not know on which port to exit the packet; the two features are incompatible.
- Broadcast storm control— This feature does not interact with the learning disable feature.
- Flooding of packets in a VLAN domain in which learning is disabled through PVL.
Partial Feature Incompatibility
Although the following features are partially incompatible with disabling MAC address learning, they still retain a large portion of their functionality:
- FlexLink—FlexLink functions and upstream convergence is not impacted. However, downstream fast convergence uses a MAC table to send dummy multicast packets for each learned MAC address upstream to expedite downstream convergence. This situation does not happen if you enabled learning disable. FlexLink downstream convergence occurs naturally, but it is slower if learning is enabled on that VLAN.
- PVLAN—To observe correct behavior, you must disable learning on the primary VLAN and all secondary VLANs associated with the primary VLAN.
Note To avoid confusion, configure PVLAN similarly on both the primary and secondary VLANs in the PVLAN space.
- Spanning Tree (STP)—Except for the UplinkFast feature, per-VLAN spanning tree functionality is not impacted. To achieve faster downstream convergence, UplinkFast forwards dummy multicast packets using learned MAC addresses. This action is not possible unless MAC learning is enabled.
Displaying Address Table Entries
You can display the MAC address table by using one or more of the privileged EXEC commands described in Table 4-4 .
Table 4-4 Commands for Displaying the MAC Address Table
|
|
show ip igmp snooping groups |
Displays the Layer 2 multicast entries for all VLANs or the specified VLAN. |
show mac address-table address |
Displays MAC address table information for the specified MAC address. |
show mac address-table aging-time |
Displays the aging time in all VLANs or the specified VLAN. |
show mac address-table count |
Displays the number of addresses present in all VLANs or the specified VLAN. |
show mac address-table dynamic |
Displays only dynamic MAC address table entries. |
show mac address-table interface |
Displays the MAC address table information for the specified interface. |
show mac address-table notification |
Displays the MAC notification parameters and history table. |
show mac address-table static |
Displays only static MAC address table entries. |
show mac address-table vlan |
Displays the MAC address table information for the specified VLAN. |