Configuring Online Diagnostics
This chapter contains the following sections:
- Information About Online Diagnostics
- Configuring Online Diagnostics
- Verifying the Online Diagnostics Configuration
- Default Settings for Online Diagnostics
- Parity Error Diagnostics
Information About Online Diagnostics
Online diagnostics provide verification of hardware components during switch bootup or reset, and they monitor the health of the hardware during normal switch operation.
Cisco Nexus Series switches support bootup diagnostics and runtime diagnostics. Bootup diagnostics include disruptive tests and nondisruptive tests that run during system bootup and system reset.
Runtime diagnostics (also known as health monitoring diagnostics) include nondisruptive tests that run in the background during normal operation of the switch.
Bootup Diagnostics
Bootup diagnostics detect faulty hardware before bringing the switch online. Bootup diagnostics also check the data path and control path connectivity between the supervisor and the ASICs. The following table describes the diagnostics that are run only during switch bootup or reset.
|
Diagnostic |
Description |
|---|---|
|
PCIe |
Tests PCI express (PCIe) access. |
|
NVRAM |
Verifies the integrity of the NVRAM. |
|
In band port |
Tests connectivity of the inband port to the supervisor. |
|
Management port |
Tests the management port. |
|
Memory |
Verifies the integrity of the DRAM. |
Bootup diagnostics also include a set of tests that are common with health monitoring diagnostics.
Bootup diagnostics log any failures to the onboard failure logging (OBFL) system. Failures also trigger an LED display to indicate diagnostic test states (on, off, pass, or fail).
You can configure Cisco Nexus device to either bypass the bootup diagnostics or run the complete set of bootup diagnostics.
Health Monitoring Diagnostics
Health monitoring diagnostics provide information about the health of the switch. They detect runtime hardware errors, memory errors, software faults, and resource exhaustion.
Health monitoring diagnostics are nondisruptive and run in the background to ensure the health of a switch that is processing live network traffic.
The following table describes the health monitoring diagnostics for the switch.
|
Diagnostic |
Description |
|---|---|
|
LED |
Monitors port and system status LEDs. |
|
Power Supply |
Monitors the power supply health state. |
|
Temperature Sensor |
Monitors temperature sensor readings. |
|
Test Fan |
Monitors the fan speed and fan control. |
![]() Note | When the switch reaches the intake temperature threshold and does not go within the limits in 120 seconds, the switch will power off and the power supplies will have to be re-seated to recover the switch |
The following table describes the health monitoring diagnostics that also run during system boot or system reset.
|
Diagnostic |
Description |
|---|---|
|
SPROM |
Verifies the integrity of backplane and supervisor SPROMs. |
|
Fabric engine |
Tests the switch fabric ASICs. |
|
Fabric port |
Tests the ports on the switch fabric ASIC. |
|
Forwarding engine |
Tests the forwarding engine ASICs. |
|
Forwarding engine port |
Tests the ports on the forwarding engine ASICs. |
|
Front port |
Tests the components (such as PHY and MAC) on the front ports. |
![]() Note | When the switch exceeds the intake temperature threshold of 40 degrees Celsius and does not decrease to within the threshold limits in 120 seconds, the switch powers off and the power supplies must be re-seated to recover the switch. |
Expansion Module Diagnostics
During the switch bootup or reset, the bootup diagnostics include tests for the in-service expansion modules in the switch.
When you insert an expansion module into a running switch, a set of diagnostics tests are run. The following table describes the bootup diagnostics for an expansion module. These tests are common with the bootup diagnostics. If the bootup diagnostics fail, the expansion module is not placed into service.
|
Diagnostic |
Description |
|---|---|
|
SPROM |
Verifies the integrity of backplane and supervisor SPROMs. |
|
Fabric engine |
Tests the switch fabric ASICs. |
|
Fabric port |
Tests the ports on the switch fabric ASIC. |
|
Forwarding engine |
Tests the forwarding engine ASICs. |
|
Forwarding engine port |
Tests the ports on the forwarding engine ASICs. |
|
Front port |
Tests the components (such as PHY and MAC) on the front ports. |
Health monitoring diagnostics are run on in-service expansion modules. The following table describes the additional tests that are specific to health monitoring diagnostics for expansion modules.
|
Diagnostic |
Description |
|---|---|
|
LED |
Monitors port and system status LEDs. |
|
Temperature Sensor |
Monitors temperature sensor readings. |
Configuring Online Diagnostics
You can configure the bootup diagnostics to run the complete set of tests, or you can bypass all bootup diagnostic tests for a faster module boot up time.
![]() Note | We recommend that you set the bootup online diagnostics level to complete. We do not recommend bypassing the bootup online diagnostics. |
The following example shows how to configure the bootup diagnostics level to trigger the complete diagnostics:
switch# configure terminal
switch(config)# diagnostic bootup level complete
Verifying the Online Diagnostics Configuration
Use the following commands to verify online diagnostics configuration information:
|
Command |
Purpose |
|---|---|
| show diagnostic bootup level |
Displays the bootup diagnostics level. |
| show diagnostic result module slot |
Displays the results of the diagnostics tests. |
Default Settings for Online Diagnostics
The following table lists the default settings for online diagnostics parameters.
|
Parameters |
Default |
|---|---|
|
Bootup diagnostics level |
complete |
Parity Error Diagnostics
Clearing Parity Errors
You can clear a corresponding Layer 2 or Layer 3 table entry (with 0s) when a parity error is detected by using the hardware profile parity-error {l2-table | l3-table} clear command. This command is effective when it is present in the running configuration and the system is booting up. In addition, the command must be enabled and after the configuration is saved, the system should be rebooted for the command to take effect.
- L2_Entry table, with no static L2_entry table entries If the L2_Entry table entry is cleared, the entry should be dynamically learned through the traffic pattern. It should not be learned through IGMP or multicast.
- L3_Entry_only (host) table Customers should not use the host table. The hardware profile unicast enable-host-ecmp command should be enabled. In this case, the customer node does not have any valid entries in the L3_Entry_only table, so clearing the L3_Entry_only entry table should not have any impact.
| Command or Action | Purpose |
|---|
This example shows how to clear parity errors in a Layer 2 table:
switch# configure terminal switch(config)# hardware profile parity-error l2-table clear switch(config)# copy running-config startup-config switch(config)# reload
This example shows how to clear parity errors in a Layer 3 table:
switch# configure terminal switch(config)# hardware profile parity-error l3-table clear switch(config)# copy running-config startup-config switch(config)# reload

Feedback