High Availability
This chapter describes how to identify and resolve problems related to High Availability.
This chapter includes the following sections:
•Information About High Availability
•Problems with High Availability
•High Availability Troubleshooting Commands
Information About High Availability
The purpose of High Availability (HA) is to limit the impact of failures—both hardware and software— within a system. The Cisco NX-OS operating system is designed for high availability at the network, system, and service levels.
The following Cisco NX-OS features minimize or prevent traffic disruption in the event of a failure:
•Redundancy— redundancy at every aspect of the software architecture.
•Isolation of processes— isolation between software components to prevent a failure within one process disrupting other processes.
•Restartability—Most system functions and services are isolated so that they can be restarted independently after a failure while other services continue to run. In addition, most system services can perform stateful restarts, which allow the service to resume operations transparently to other services.
•Supervisor stateful switchover— Active/standby dual supervisor configuration. State and configuration remain constantly synchronized between two Virtual Supervisor Modules (VSMs) to provide seamless and statefu1 switchover in the event of a VSM failure.
The Cisco Nexus 1000V system is made up of the following:
•Virtual Ethernet Modules (VEMs) running within virtualization servers. These are represented as modules within the VSM.
•A remote management component, for example. VMware vCenter Server.
•One or two VSMs running within Virtual Machines (VMs)
System-Level High Availability
The Cisco Nexus 1000V supports redundant VSM virtual machines — a primary and a secondary — running as an HA pair. Dual VSMs operate in an active/standby capacity in which only one of the VSMs is active at any given time, while the other acts as a standby backup. The state and configuration remain constantly synchronized between the two VSMs to provide a statefu1 switchover if the active VSM fails
Single or Dual Supervisors
The Cisco Nexus 1000V system is made up of the following:
•Virtual Ethernet Modules (VEMs) running within virtualization servers (these are represented as modules within the VSM)
•A remote management component, for example. VMware vCenter Server.
•One or two Virtual Supervisor Modules (VSMs) running within Virtual Machines (VMs)
|
|
•Stateless—Service restarts from the startup configuration •Stateful—Service resumes from previous state. |
•One active VSM and one standby VSM. •The active VSM runs all the system applications and controls the system. •On the standby VSM, the applications are started and initialized in standby mode. They are also synchronized and kept up to date with the active VSM in order to maintain the runtime context of "ready to run." •On a switchover, the standby VSM takes over for the active VSM. |
Network-Level High Availability
The Cisco Nexus 1000V HA at the network level includes port channels and Link Aggregation Control Protocol (LACP). A port channel bundles physical links into a channel group to create a single logical link that provides the aggregate bandwidth of up to eight physical links. If a member port within a port channel fails, the traffic previously carried over the failed link switches to the remaining member ports within the port channel.
Additionally, LACP lets you configure up to 16 interfaces into a port channel. A maximum of eight interfaces can be active, and a maximum of eight interfaces can be placed in a standby state.
For additional information about port channels and LACP, see the Cisco Nexus 1000V Layer 2 Switching Configuration Guide, Release 4.0.
Problems with High Availability
|
|
|
The active VSM does not see the standby VSM. |
Roles are not configured properly. •Check the role of the two VSMs using the show system redundancy status command. |
1. Confirm that the roles are the primary and secondary role, respectively. 2. If needed, use the system redundancy role command to correct the situation. 3. Save the configuration if roles are changed. |
Network connectivity problems. •Check the control and management VLAN connectivity between VSM at the upstream and virtual switches. |
If network problems exist: 1. From the vSphere client, shut down the VSM, which should be in standby mode. 2. From the vSphere client, bring up the standby VSM after network connectivity is restored. |
The active VSM does not complete synchronization with the standby VSM. |
Version mismatch between VSMs. •Check that primary and secondary VSM are using the same image version using show version command. |
If the active and standby VSM software versions differ, reinstall the secondary VSM with the same version used in the primary. |
Fatal errors during gsync process. •Check the gsyncctrl log using the show system internal log sysmgr gsyncctrl command and look for fatal errors. |
Reload the standby VSM using the reload module module-number command, where module-number is the module number for the standby VSM. |
The standby VSM reboots periodically. |
The VSM has connectivity only through the management interface. •When a VSM is able to communicate through the management interface, but not through the control interface, the active VSM detects the situation and resets the standby VSM to prevent the two VSMs from being in HA mode and out of sync. •Check the output of the show system internal redundancy info command and verify if the degraded_mode flag is set to true. |
Check control VLAN connectivity between the primary and secondary VSMs. |
VSMs have different versions. Enter the debug system internal sysmgr all command and look for the active_verctrl entry that indicates a version mismatch, as the following output shows: 2009 May 5 08:34:15.721920 sysmgr: active_verctrl: Stdby running diff version- force download the standby sup . |
Isolate the standby VSM and boot it. Use the show version command to check the software version in both VSMs. Install the image matching the Active VSM on the standby. |
Both VSMs are in active mode. |
Network connectivity problems. •Check for control and management VLAN connectivity between the VSM at the upstream and virtual switches. •When the VSM cannot communicate through any of these two interfaces, they will both try to become active. |
If network problems exist: 1. From the vSphere client, shut down the VSM, which should be in standby mode. 2. From the vSphere client, bring up the standby VSM after network connectivity is restored. |
Different domain IDs in the two VSMs Check domain value using show system internal redundancy info command. |
If needed, update the domain ID and save it to the startup configuration. •Upgrading the domain ID in a dual VSM system must be done following a certain procedure. –Isolate the VSM with the incorrect domain ID so that it cannot communicate with the other VSM. –Change the domain ID in the isolated VSM, save configuration, and power off the VSM. –Reconnect the isolated VSM and power it on. |
High Availability Troubleshooting Commands
This section lists commands that can be used troubleshoot problems related to High Availability.
To list process logs and cores, use the following commands:
•show cores
VDC No Module-num Process-name PID Core-create-time
------ ---------- ------------ --- ----------------
1 1 private-vlan 3207 Apr 28 13:29
•show processes log [pid pid]
n1000V# show processes log
VDC Process PID Normal-exit Stack Core Log-create-time
--- --------------- ------ ----------- ----- ----- ---------------
1 private-vlan 3207 N Y N Tue Apr 28 13:29:48 2009
n1000V# show processes log pid 3207
======================================================
Description: Private VLAN
Started at Wed Apr 22 18:41:25 2009 (235489 us)
Stopped at Tue Apr 28 13:29:48 2009 (309243 us)
Uptime: 5 days 18 hours 48 minutes 23 seconds
Start type: SRV_OPTION_RESTART_STATELESS (23)
Death reason: SYSMGR_DEATH_REASON_FAILURE_SIGNAL (2) <-- Reason for the process abort
Last heartbeat 46.88 secs ago
System image name: nexus-1000v-mzg.4.0.4.SV1.1.bin
System image version: 4.0(4)SV1(1) S25
Exit code: signal 6 (core dumped) <-- Indicates that a cores for the process was
generated.
To check redundancy status, use the following commands:
•show system redundancy status
N1000V# show system redundancy status
administrative: primary <-- Configured redundancy role
operational: primary <-- Current operational redundancy role
Redundancy state: Active <-- Redundancy state of this VSM
Internal state: Active with HA standby
Redundancy state: Standby <-- Redundancy state of the other VSM
Supervisor state: HA standby
Internal state: HA standby <-- The standby VSM is in HA mode and in sync
To check the system internal redundancy status, use the following command:
•show system internal redundancy info
n1000V# show system internal redundancy info
domain: 184 <-- Domain id used by this VSM
role: primary <-- Redundancy role of this VSM
status: RDN_ST_AC <-- Indicates redundancy state (RDN_ST) of the this VSM is Active
(AC)
status: RDN_ST_SB <-- Indicates redundancy state (RDN_ST) of the other VSM is
Standby (SB)
degraded_mode: false <-- When true, it indicates that communication through the
control interface is faulty
Redun Device 0: <-- This device maps to the control interface
tx_set_ver_req_pkts: 11590
tx_heartbeat_req_pkts: 442571
rx_heartbeat_rsp_pkts: 442546 <-- Counter should be increasing, as this indicates
that communication between VSM is working properly.
Redun Device 1: <-- This device maps to the mgmt interface
tx_set_ver_req_pkts: 11589
tx_heartbeat_req_pkts: 12
rx_heartbeat_rsp_pkts: 0 <-- When communication between VSM through the control
interface is interrupted but continues through the mgmt interface, the
rx_heartbeat_rsp_pkts will increase.
To check the system internal sysmgr state, use the following command:
•show system internal sysmgr state
N1000V# show system internal sysmgr state
The master System Manager has PID 1988 and UUID 0x1.
Last time System Manager was gracefully shutdown.
The state is SRV_STATE_MASTER_ACTIVE_HOTSTDBY entered at time Tue Apr 28 13:09:13
2009.
The '-b' option (disable heartbeat) is currently disabled.
The '-n' (don't use rlimit) option is currently disabled.
Hap-reset is currently enabled.
Watchdog checking is currently disabled.
Watchdog kgdb setting is currently enabled.
The trace mask is 0x00000000, the syslog priority enabled is 3.
The '-d' option is currently disabled.
The statistics generation is currently enabled.
cardstate = SYSMGR_CARDSTATE_ACTIVE .
cardstate = SYSMGR_CARDSTATE_ACTIVE (hot switchover is configured enabled).
Configured to use the real platform manager.
Configured to use the real redundancy driver.
Redundancy register: this_sup = RDN_ST_AC, other_sup = RDN_ST_SB.
Remote addresses: MTS - 0x00000201/3 IP - 127.1.1.2
Module online notification received.
Local super-state is: SYSMGR_SUPERSTATE_STABLE
Standby super-state is: SYSMGR_SUPERSTATE_STABLE
Swover Reason : SYSMGR_SUP_REMOVED_SWOVER <-- Reason for the last switchover
Total number of Switchovers: 0 <-- Number of switchovers
>> Duration of the switchover would be listed, if any.
Total latency: 0 Max latency: 0
Total exec: 0 Max exec: 0
To reload a module, use the following command:
•reload module
This command reloads the secondary VSM.
Note Issuing the reload command without specifying a module will reload the whole system.
To attach to the standby VSM console, use the following command.
•attach module
The standby VSM console is not accessible externally, but can be accessed from the active VSM through the attach module module-number command.
This command attaches to the console of the secondary VSM.