VLAN Configuration
Note
|
Use separate subnet and VLANs for each of the following networks.
|
|
VLAN for Hypervisor and HyperFlex management
|
VLAN Name
VLAN ID
|
Name: hx-inband-mgmt
Default VLAN ID: 3091
|
VLAN for HyperFlex storage traffic
|
VLAN Name
VLAN ID
|
Name: hx-storage-data
Default VLAN ID: 3092
|
VLAN for VM vMotion
|
VLAN Name
VLAN ID
|
Name: hx-vmotion
Default VLAN ID: 3093
|
VLAN for VM Network
|
VLAN Name
VLAN ID(s)
|
Name: vm-network
Default VLAN ID: 3094
A comma-separated list of guest VLANs.
|
MAC Pool
|
MAC Pool Prefix
|
Configure MAC Pool prefix by adding in two more hex characters (0-F).
For example, 00:25:B5:A0.
|
'hx-ext-mgmt' IP Pool for Out-of-Band CIMC
|
IP Blocks
|
The range of IP addresses designated for the HyperFlex nodes. This can be a comma-separated list of values for the guest VLANs.
For example, 10.193.211.124-127, 10.193.211.158-163
|
Subnet Mask
|
Set the subnet to the appropriate level to limit and control IP addresses.
For example, 255.255.0.0.
|
Gateway
|
IP address.
For example, 10.193.0.1.
|
iSCSI Storage
Note
|
This must be configured upfront if you want to use external storage at any point in the future.
|
|
Enable iSCSI Storage checkbox
|
Check to configure iSCSI storage. |
VLAN A Name
|
Name of the VLAN associated with the iSCSI vNIC, on the primary fabric interconnect (FI-A).
|
VLAN A ID
|
ID of the VLAN associated with the iSCSI vNIC, on the primary fabric interconnect (FI-A).
|
VLAN B Name
|
Name of the VLAN associated with the iSCSI vNIC, on the subordinate fabric interconnect (FI-B).
|
VLAN B ID
|
ID of the VLAN associated with the iSCSI vNIC, on the subordinate fabric interconnect (FI-A).
|
FC Storage
Note
|
This must be configured upfront if you want to use external storage at any point in the future.
|
|
Enable FC Storage checkbox
|
Check to enable FC Storage.
|
WWxN Pool
|
A WWN pool that contains both WW node names and WW port names. For each fabric interconnect, a WWxN pool is created for WWPN
and WWNN.
|
VSAN A Name
|
The name of the VSAN for the primary fabric interconnect (FI-A). By default, this is set to hx-ext-storage-fc-a .
|
VSAN A ID
|
The unique identifier assigned to the network for the primary fabric interconnect (FI-A).
Caution
|
Do not enter VSAN IDs that are currently used on the UCS or HyperFlex system. If you enter an existing VSAN ID in the installer
which utilizes UCS zoning, zoning will be disabled in your existing environment for that VSAN ID.
|
|
VSAN B Name
|
The name of the VSAN for the subordinate fabric interconnect (FI-B). By default, this is set to hx-ext-storage-fc-b .
|
VSAN B ID
|
The unique identifier assigned to the network for the subordinate fabric interconnect (FI-B).
Caution
|
Do not enter VSAN IDs that are currently used on the UCS or HyperFlex system. If you enter an existing VSAN ID in the installer
which utilizes UCS zoning, zoning will be disabled in your existing environment for that VSAN ID.
|
|
Advanced
|
UCS Firmware Version
|
Select the UCS firmware version to associate with the HX servers from the drop-down list. The UCS firmware version must match
the UCSM version. See the latest Cisco HX Data Platform Release Notes for more details.
For example, 3.2(1d).
|
HyperFlex Cluster Name
|
The name applied to a group of HX Servers in a given cluster. This is a user-defined name. The HyperFlex cluster name adds
a label to service profiles for easier identification.
|
Org Name
|
Specify a unique Org Name. This ensures isolation of the HyperFlex environment from the rest of the UCS domain.
|