The PowerKEY encrypted VOD LED is active and communicates with the external SRM device after configuring the encryption type
on the line card, VCGs, binding of SDGs, and LED with GQI protocol are completed.
To verify the Logical Edge Device configuration, use the show cable video logical-edge-device name led name command or the
show cable video logical-edge-device id led number command as shown in the example below:show cable video logical-edge-device name pkvodled
Logical Edge Device: pkvodled
Id: 1
Protocol: gqi
Service State: Active
Discovery State: Disable
Management IP: 1.23.2.10
MAC Address: 54a2.740d.dc99
Number of Servers: 1
Server 1: 1.200.3.75
Reset Interval: 8
Keepalive Interval: 10
Retry Count:3
Number of Virtual Carrier Groups: 1
Number of Share Virtual Edge Input: 1
Number of Physical Qams: 20
Number of Sessions: 0
No Reserve PID Range
Virtual Edge Input:
Input Port VEI Slot/Bay Bundle Gateway
ID IP ID IP
-----------------------------------------------------------------
1 174.10.2.1 7/0 - -
Verify the following:
-
The service state of the LED should be active and the other fields must be same as the configured values.
-
The connection to the remote SRM should be displayed to ensure that there is a valid network connection to the SRM.
-
Execute the show cable video gqi connections command. The following is the sample output when the connection is not established
to the SRM:
LED Management Server Connection Version Event Reset Encryption
ID IP IP Status Pending Indication Discovery
---------------------------------------------------------------------------------
1 1.23.2.10 1.200.3.75 Not Connected 0 0 Not Sent Not Sent
The following is the sample output when the connection is established to the SRM:
LED Management Server Connection Version Event Reset Encryption
ID IP IP Status Pending Indication Discovery
---------------------------------------------------------------------------------
1 1.23.2.10 1.200.3.75 Not Connected 2 0 ACKED ACKED
After the connection is established, the SRM may create encrypted sessions on the carriers of the LED.
-
To view the encrypted sessions, use the show cable video session logical-edge-device id led name summary command as shown
in the example below:
show cable video session logical-edge-device id 1summary
Video Session Summary:
Active : 1 Init : 0 Idle : 0
Off : 0 Blocked : 0 PSI-Ready : 1
UDP : 1 ASM : 0 SSM : 0
Remap : 1 Data : 0 Passthru : 0
Total Sessions: 1
-
The individual session information can be displayed for the entire LED, for a particular port or line card. The details of
a single session may be displayed by specifying a session-id or session-name. To display all the sessions on the LED, use
the show cable video session logical-edge-device name led name command as shown in the example below:
show cable video session logical-edge-device name pkvodled
Total Sessions = 1
Session Output Streaming Session Destination UDP Output Input Output Input
Id Port Type Type Port Program State State Bitrate
---------------------------------------------------------------------------------
1048576 1 Remap UDP 174.101.1.1 4915 1 ACTIVE-PSI ON 732788
Output Encrypt Encrypt Session
Bitrate Type Status Name
-----------------------------------
1715446 PowerKey Encrypted 0x0000000000001
If the session is encrypted and transmitted properly, the session is displayed as shown in the above example. The input state
is "ACTIVE-PSI". The output state is "ON". For PowerKEY encrypted sessions, the Encrypt Type will be "PowerKey" and the Encrypt
Status will be "Encrypted".
If the session is created as a clear session, then the Encrypt Type will be "CLEAR" and the Encrypt Status will be "-".