Service provider networks are under tremendous pressure as traffic from video, mobile, and collaboration applications grow exponentially. To meet these demands, they need a transport platform that can cost-effectively scale with operational ease. The Cisco® ONS 15454 M6 Multiservice Transport Platform (MSTP) sets the industry benchmark for compact, easy to operate, fast, and intelligent DWDM solutions. It includes a unique set of integrated features and its low power consumption reduces capital and operating expenses. The flexible Cisco ONS 15454 M6 platform supports a broad range of solutions, from edge aggregation solutions to metro core and long haul applications.
Key Features and Benefits
The Cisco ONS 15454 M6 chassis has two slots for redundant control cards and six slots for service cards (Figure 2). These six line card slots provide increased power and cooling capability over the original Cisco ONS 15454 chassis and a high-speed backplane for card-to-card interconnection. You can configure the Cisco ONS 15454 M6 with integrated and redundant DC or AC power inputs or a single power module for low-power and low-cost configurations. The Electrical Connection Unit (ECU, Figure 3) is a narrow, front-facing termination panel for all management, alarm, and multi-shelf connections. With all connections to the Cisco ONS 15454 M6 located on the front, this platform is ideal for cabinet installations and ETSI front connection requirements, making it truly global in its appeal. The ECU comes in two versions; the ECU2 version includes an RJ-45 connector for time-of-day (ToD) input and pulse-per-second (PPS) input.
Although the node can be configured with redundant control or processor cards, simplex mode or single control-card operation is permitted. The Cisco ONS 15454 M6 has a built-in memory module to back up the software package, IP address, and circuit database, making simplex mode more attractive in cost-sensitive applications. This built-in backup memory improves mean time to repair (MTTR) and increases operational simplicity. The Cisco ONS 15454 M6 can connect via USB to up to 12 Cisco ONS passive devices for inventory management. Some Cisco ONS 15216 passive devices, such as the single-module reconfigurable optical add-drop multiplexer (ROADM) patch panel, have an erasable programmable ROM (EEPROM) in the device that the Cisco ONS 15454 M6 can read, so it appears in the Cisco Transport Controller inventory management pane.
You can mount the Cisco ONS 15454 M6 MSTP into 19-inch, 21-inch, or 23-inch racks or cabinets. Brackets come with the shelf assembly and can also be ordered as spares. Optional air deflectors can be used in 21-inch and 23-inch installations. With 19-inch brackets, the airflow is right to left. With 21-inch brackets, you can select the airflow as right to left; right front in, and left front out; left up out; or left back out. With 23-inch brackets, airflow is from right front in to left back out.
The Cisco ONS 15454 M6 MSTP has a single high-capacity fan tray assembly where the three fans are individually monitored and controlled. If a single fan fails, a fan fail alarm is raised and the other fans increase in speed to provide sufficient airflow to give you time to safely replace the fan tray.
Doors are optional and hence do not come with the shelf assembly. They can be ordered as spares.
Specifically designed for the Cisco ONS 15454 M6 MSTP are control cards that consolidate the functions of the shelf processor, optical service channel (OSC) termination, multi-shelf switch, and external alarm contacts into just one card. The OSC also supports Fast Ethernet and Gigabit Ethernet connections, in addition to OC-3/STM-1, providing more bandwidth for use with the user data channel (UDC).
Product Specifications
Table 1 lists the modules that make up the Cisco ONS 15454 M6 MSTP.
Table 1. Cisco ONS 15454 M6 Modules
Module |
Part Number |
Common Equipment for the Cisco ONS 15454 M6 |
|
Shelf Assembly with brackets Chassis door (optional), and Deep Door |
15454-M6-SA 15454-M6-DR, 15454-M6-DDR |
Fan Tray Assembly Chassis air filter |
15454-M6-FTA, 15454-M6-FTA2 15454-M6-FTF |
External Connection Unit Integrated multishelf connection Cisco Element Management System connection UDC connection Voice-over-IP (VoIP) connection Alarms connection USB connection to passive Cisco ONS devices for inventory management Building Integrated Timing Supply (BITS) 1 and BITS 2 input and output (ANSI and ETSI) Time of Day (ToD)/Pulse Per Second (PPS) |
15454-M6-ECU
15454-M6-ECU2 |
LCD Status and Backup Memory |
15454-M6-LCD |
Power Options DC power module with ANSI and ETSI connectors AC power module with universal IEC power connector |
15454-M6-DC, 15454-M6-DC20 15454-M6-AC, 15454-M6-AC2 |
Brackets and Air Deflectors (Optional spares) 19-in., 21-in., and 23-in. brackets 21-in. air deflectors 23-in. air deflectors |
15454-M6-BRKT 15454-M6-DEFL21 15454-M6-DEFL23 |
Common Equipment for the Cisco ONS 15454 M6 and M2 |
|
Transport Node Controller card (TNC) Transport Shelf Controller card (TSC) Enhanced TNC card Enhanced TSC card |
15454-M-TNC 15454-M-TSC 15454-M-TNCE 15454-M-TSCE |
Slot-Filler Cards Line-card blank Line-card slot-detectable filler Control-card slot-detectable filler Cisco ONS 15454 M6 Power Module blank filler |
15454-BLANK 15454-M-FILLER 15454-M-T-FILLER 15454-M6-PWRFLR |
Table 2. Cisco ONS 15454 M6 Cables for Original AC power Supply (15454-M6-AC)
Product Part Number |
Description |
Length |
Gauge |
Connector 1 |
Connector 2 |
15454-M2-DCCBL-LE(=) |
DC power cable for ETSI left exit |
10 m |
12 AWG |
Power D-Sub 2 poles |
none |
15454-M6-DCCBL-LE(=) |
DC power cable for ETSI left exit |
10 m |
8 AWG |
Power D-Sub 3 poles |
none |
15454-M6-DCCBL-RE(=) |
DC power cable for ETSI right exit |
10 m |
8 AWG |
Power D-Sub 3 poles |
none |
15454-M-ACCBL-L(=) |
AC power cable ANSI 110Vac left exit |
3 m |
15A - 125V |
C13 |
NEMA 5-15P |
15454-M-ACCBL-L2(=) |
AC power cable ANSI 220Vac left exit |
3 m |
15A - 250V |
C13 |
NEMA 6-15P |
15454-M-ACCBL-R(=) |
AC power cable ANSI 110Vac right exit |
3 m |
15A - 125V |
C13 |
NEMA 5-15P |
15454-M-ACCBL-R2(=) |
AC power cable ANSI 220Vac right exit |
3 m |
15A - 250V |
C13 |
NEMA 6-15P |
15454-M-ACL6-L(=) |
AC power cable for Data Center |
3 m |
15A - 250V |
C13 |
NEMA WD 6 L6-20P |
15454-M-ACL6-R(=) |
AC power cable for Data Center |
3 m |
15A - 250V |
C13 |
NEMA WD 6 L6-20P |
15454-M-CBL-LARG(=) |
AC power cable - ARG left exit |
3 m |
10A - 250V |
C13 |
IRAM 2073 - IEC 60884-1 |
15454-M-CBL-LAUS(=) |
AC power cable - AUS left exit |
3 m |
10A - 250V |
C13 |
AS/NZS 3112: 2000 |
15454-M-CBL-L-CHI(=) |
AC power cable - China left exit |
3 m |
10A - 250V |
C13 |
GB2099.1/GB1002 |
15454-M-CBL-L-EU(=) |
AC power cable - EU left exit |
3 m |
10A - 250V |
C13 |
CEE 7 STANDARD SHEET VII |
15454-M-CBL-L-IND(=) |
AC power cable - India left exit |
3 m |
10A - 250V |
C13 |
IS 1293 |
15454-M-CBL-L-JPN(=) |
AC power cable - Japan left exit |
3 m |
15A - 125V |
C13 |
JIS C8303 & JIS C8306 |
15454-M-CBL-LKOR(=) |
AC power cable - KOR left exit |
3 m |
10A - 250V |
C13 |
K60884-01 |
15454-M-CBL-L-UK(=) |
AC power cable - UK left exit |
3 m |
10A - 250V |
C13 |
BS 1363/A & SS145/A |
15454-M-CBL-RARG(=) |
AC power cable - ARG right exit |
3 m |
10A - 250V |
C13 |
IRAM 2073 - IEC 60884-1 |
15454-M-CBL-RAUS(=) |
AC power cable - AUS right exit |
3 m |
10A - 250V |
C13 |
AS/NZS 3112: 2000 |
15454-M-CBL-R-CHI(=) |
AC power cable - China right exit |
3 m |
10A - 250V |
C13 |
GB2099.1/GB1002 |
15454-M-CBL-R-EU(=) |
AC power cable - EU right exit |
3 m |
10A - 250V |
C13 |
CEE 7 STANDARD SHEET VII |
15454-M-CBL-R-IND(=) |
AC power cable - India right exit |
3 m |
10A - 250V |
C13 |
IS 1293 |
15454-M-CBL-R-JPN(=) |
AC power cable - Japan right exit |
3 m |
15A - 125V |
C13 |
JIS C8303 & JIS C8306 |
15454-M-CBL-RKOR(=) |
AC power cable - KOR right exit |
3 m |
10A - 250V |
C13 |
K60884-01 |
15454-M-CBL-R-UK(=) |
AC power cable - UK right exit |
3 m |
10A - 250V |
C13 |
BS 1363/A & SS145/A |
Table 3. Cisco ONS 15454 M6 Cables for AC2 Power Supply (15454-M6-AC2)
Product Part Number |
Description |
Length |
Gauge |
Connector 1 |
Connector 2 |
15454-M-ACCBL2-L(=) |
AC2 power cable ANSI 110Vac left exit |
3 m |
20A - 125V |
C19 |
NEMA 5-20P |
15454-M-ACCBL2-L2(=) |
AC2 power cable ANSI 220Vac left exit |
3 m |
20A - 250V |
C19 |
NEMA 6-20P |
15454-M-ACCBL2-R(=) |
AC2 power cable ANSI 110Vac right exit |
3 m |
20A - 125V |
C19 |
NEMA 5-20P |
15454-M-ACCBL2-R2(=) |
AC2 power cable ANSI 220Vac right exit |
3 m |
20A - 250V |
C19 |
NEMA 6-20P |
15454-M-CBL2-LARG(=) |
AC2 power cable - ARG left exit |
3 m |
16A - 250V |
C19 |
IRAM 2073 - IEC 60884-1 |
15454-M-CBL2-LAUS(=) |
AC2 power cable - AUS left exit |
3 m |
16A - 250V |
C19 |
AS/NZS 3112: 2000 |
15454-M-CBL2L-CHI(=) |
AC2 power cable - China left exit |
3 m |
16A - 250V |
C19 |
GB2099.1/GB1002 |
15454-M-CBL2-L-EU(=) |
AC2 power cable - EU left exit |
3 m |
16A - 250V |
C19 |
CEE 7 STANDARD SHEET VII |
15454-M-CBL2L-IND(=) |
AC2 power cable - India left exit |
3 m |
16A - 250V |
C19 |
IS 1293 |
15454-M-CBL2L-JPN(=) |
AC2 power cable - Japan left exit |
3 m |
20A - 125V |
C19 |
JIS C8303 & JIS C8306 |
15454-M-CBL2-LKOR(=) |
AC2 power cable - KOR left exit |
3 m |
16A - 250V |
C19 |
K60884-01 |
15454-M-CBL2-L-UK(=) |
AC2 power cable - UK left exit |
3 m |
13A - 250V |
C19 |
BS 1363/A & SS145/A |
15454-M-CBL2-RARG(=) |
AC2 power cable - ARG right exit |
3 m |
16A - 250V |
C19 |
IRAM 2073 - IEC 60884-1 |
15454-M-CBL2-RAUS(=) |
AC2 power cable - AUS right exit |
3 m |
16A - 250V |
C19 |
AS/NZS 3112: 2000 |
15454-M-CBL2R-CHI(=) |
AC2 power cable - China right exit |
3 m |
16A - 250V |
C19 |
GB2099.1/GB1002 |
15454-M-CBL2-R-EU(=) |
AC2 power cable - EU right exit |
3 m |
16A - 250V |
C19 |
CEE 7 STANDARD SHEET VII |
15454-M-CBL2R-IND(=) |
AC2 power cable - India right exit |
3 m |
16A - 250V |
C19 |
IS 1293 |
15454-M-CBL2R-JPN(=) |
AC2 power cable - Japan right exit |
3 m |
20A - 125V |
C19 |
JIS C8303 & JIS C8306 |
15454-M-CBL2-RKOR(=) |
AC2 power cable - KOR right exit |
3 m |
16A - 250V |
C19 |
K60884-01 |
15454-M-CBL2-R-UK(=) |
AC2 power cable - UK right exit |
3 m |
13A - 250V |
C19 |
BS 1363/A & SS145/A |
Table 4. Cisco ONS 15454 M6 Miscellaneous Cables
Product Part Number |
Description |
Length |
Gauge |
Connector 1 |
Connector 2 |
15454-M2-DCCBL-LE(=) |
DC power cable for ETSI left exit |
10 m |
12 AWG |
Power D-Sub 2 poles |
none |
15454-M6-DCCBL-LE(=) |
DC power cable for ETSI left exit |
10 m |
8 AWG |
Power D-Sub 3 poles |
none |
15454-M6-DCCBL-RE(=) |
DC power cable for ETSI right exit |
10 m |
8 AWG |
Power D-Sub 3 poles |
none |
15454-M-120TMGCBL(=) |
BITS IN/OUT cable for ANSI |
0.6 m |
COAX 23 AWG |
DIN 1.0/2.3 |
2 WIRE WRAP PINS |
15454-M-ALMCBL(=) 15454-M-ALMCBL2(=) |
SCSI Alarm cable SCSI Alarm cable limited to 8 inputs |
20 m 20 m |
28 AWG 24 AWG |
Mini SCSI Mini SCSI |
None None |
15454-M-TMGCBL(=) |
BITS IN/OUT cable for ETSI |
20 m |
COAX 23 AWG |
DIN 1.0/2.3 |
none |
15454-M-USBCBL(=) |
USB cable for passive devices |
3 m |
28#/1P + 24#/2C + AEB |
USB "A" MALE |
USB "A" MALE |
Table 5 provides details about physical and operational specifications for the Cisco ONS 15454 M2 MSTP.
Table 5. Product Specifications
Item |
Specification |
Power Requirements |
Maximum |
M6 AC power configuration |
1400W |
M6 DC power configuration |
1400W |
Power Consumption |
|
M6 fan tray assemblies |
120W |
M6 AC power module |
Original AC power supply: 15% of the sum of the max consumption of all populated cards AC2 power supply: 15% of the sum of the max consumption of all populated cards |
M6 DC power modules |
40W |
Physical Dimensions |
|
Rack mounting |
19- or 23-in. (483- or 584-mm) EIA rack mounting |
Shelf assembly |
|
Cisco ONS 15454 M6 shelf assembly |
(H x W x D): 10.45 x 17.45 x 11.02 in. (265.4 x 443.3 x 280 mm) |
Environmental conditions |
|
Storage temperature |
-40 to 158ºF (-40 to 70ºC) |
Operating temperature
● Normal
● Short-term1
|
32 to 131ºF (0 to 55ºC) 23 to 131ºF (-5 to 55ºC) |
Relative humidity
● Normal
● Short-term2
|
5 to 85%, noncondensing 5 to 90% but not to exceed 0.024 kg water/kg of dry air |
Regulatory Standards Compliance
Table 6 summarizes regulatory standard compliance and agency approvals.
Table 6. Regulatory Standard Compliance and Agency Approvals
ANSI (Cisco ONS 15454) System |
ETSI (Cisco ONS 15454E) System |
Supported Countries |
|
● Canada
● United States
● Korea
|
● Europe
● Latin America
● Japan
● Asia Pacific
● Middle East and Africa
|
EMC (Class A) |
|
● ICES-003 Issue 4(2004)
● GR-1089-CORE, Issue 4
(Type 2 and Type 4 equipment)
● GR-1089-CORE - Issue 03 (Oct 2002)
(Objective O3-2 - Section 3.2.1 - Radiated Emissions requirements with all doors open)
● FCC 47CFR15, Class A subpart B (2006)
|
● EN 300 386 v1.3.3 (2005) and v1.4.1 (2007)
● CISPR 22 - Fifth edition (2005-04) Class A and the amendment 1 (2005-07)
● CISPR 24 - First edition (1997-09) and amendment 1 (2001-07) and amendment 2 (2002-10).
● EN 55022:1998 Class A - CENELEC Amendment A2:2003
● EN 55024:1998 - CENELEC Amendment A1:2001 and Amendment A2:2003
● Resolution 237 (Brazil)
● VCCI V-3/2006.04
● EN 61000-6-1:2001
● EN 61000-6-2:1999
|
Safety |
|
● UL/CSA 60950-1 2nd Ed. 2011
● GR-1089-CORE, Issue 4 (Type 2 and Issue 6 equipment) |
● UL/CSA 60950-1 2nd Ed. 2011
● IEC 60950-1 2nd Ed. + Amendment 1:2009, EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011 (with all country deviations)
|
Environmental |
|
● GR-63-CORE, Issue 3 (2006)
|
● ETS 300-019-2-1 V2.1.2 (Storage, Class 1.1)
● ETS 300-019-2-2 V2.1.2 (Transportation, Class 2.3)
● ETS 300-019-2-3 V2.1.2 (Operational, Class 3.1E)
● EU WEEE regulation
● EU RoHS regulation
|
Power and Grounding |
|
● GR-1089-CORE, Issue 4
|
● ETS 300 132-2
|
Optical Safety |
|
● EN or IEC-60825-2 Third edition (2004-06)
● EN or IEC 60825-1 Consol. Ed. 1.2 - incl. am1+am2 (2001-08)
● 21CFR1040 (2004/04) (Accession Letter and CDRH Report)
● IEC-60825-2 Third edition (2004-06)
● ITU-T G.664 (2006)
|
|
Miscellaneous |
|
● Acoustic noise
◦ GR-63-CORE, Issue 3 (2006)
◦ ETS 300 753 ed.1 (1997-10)
● Rain, sand, dust, and moisture proofing
◦ AS 1939-1990, 4.2, IP 53
● Mechanical shock and bumps
◦ AS1099-2.27
● Customer-specific requirements
◦ AT&T Network Equipment Development Standards (NEDS) Generic Requirements, AT&T 802-900-260
◦ SBC TP76200MP
◦ Verizon SIT.NEBS.NPI.2002.010
|
Ordering Information
To place an order, visit the Cisco Ordering homepage and refer to Table 7. To download software, visit the Cisco Software Center: http://www.cisco.com/cisco/software/type.html?mdfid=278281788&i=rm.
Table 7. Ordering Information
Warranty
The following warranty terms apply to the Cisco ONS 15454 M6 MSTP as well as services you may use during the warranty period. Your formal warranty statement appears in the Cisco information packet that accompanies your Cisco product.
● Hardware warranty duration: Five years
● Software warranty duration: One year
● Hardware replacement, repair, or refund procedure: Cisco or our service center will use commercially reasonable efforts to ship a replacement part for delivery within 15 working days after receipt of the defective product at Cisco's site. Actual delivery times of replacement products may vary depending on customer location.
Product warranty terms and other information applicable to Cisco products are available at: http://www.cisco.com/go/warranty.
Service and Support
Cisco Services make networks, applications, and the people who use them work better together.
Today, the network is a strategic platform in a world that demands better integration among people, information, and ideas. The network works better when services, together with products, create solutions aligned with business needs and opportunities.
The unique Cisco Lifecycle approach to services defines the requisite activities at each phase of the network lifecycle to help ensure service excellence. With a collaborative delivery methodology that joins the resources of Cisco, our skilled network of partners, and our customers, we achieve the best results.
For More Information
For more information about the Cisco ONS 15454 Multiservice Transport Platform, contact your local Cisco account representative or visit Cisco at: http://www.cisco.com/go/optical or http://www.cisco.com/go/IPoDWDM.