November 4, 2009
NOTICE:
THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision History
Revision Date Comment 1.0 04-NOV-2009 Initial Public Release.
Products Affected
Products Affected MDS NX-OS - 4.1MDS NX-OS - 4.2(1b) MDS SAN OS - 3.3(4)
Problem Description
Executing any of the following commands on a MDS switch or collecting the same information via Fabric Manager may cause a kernel panic on the supervisor:
Version Offending Commands 3.3(4) show hardware internal mgmt0 stats
show hardware internal eobc stats
show tech-support
show tech-support details
tac-pac
4.1(x)
4.2(2) or below
show hardware internal mgmt0 stats
show hardware internal eobc stats
show tech-support
show tech-support details
tac-pac
show tech-support ha
show tech-support sysmgr
This issue is only applicable to switches with Supervisor 2 in MDS9506, MDS9509 or MDS9513 chassis. In a dual supervisor switch this will force a supervisor switchover. In single supervisor systems the switch will reload.
Issuing the commands in succession on a dual supervisor switch will cause a switch reload if the command is executed the second time before it is in a ha-standby state.
Background
The kernel panic is caused by running either of the following statistics commands:
show hardware internal mgmt0 stats
show hardware internal eobc stats
This issue only affects removable supervisor 2 modules.
Problem Symptoms
In a dual supervisor switch this will force a supervisor switchover. In single supervisor systems the switch will reload.
Workaround/Solution
Refrain from using "show hardware internal mgmt0 stats" and "show hardware internal eobc stats".
Before running "show tech-support", "show tech-support details" or "tacpac" (from FM/DM or CLI), load a plugin (available at www.cisco.com) which will patch the offending commands. The plug-in should be loaded on the standby supervisor also. The plug-in is not persistent across switchovers and should be loaded any time a switchover occurs.
Upgrade to one of the following software releases when it becomes available.
3.3(4a) or above
4.2(3) or above
Using the Debug Plug-in
Commands to issue are in italics.
- Download the plug in from the Cisco Software Download Center: http://tools.cisco.com/support/downloads/go/Redirect.x?mdfid=282764109 and select release "1.0"
- Make a copy of the downloaded gplug
copy bootflash:m9500-sup2-showtech-FN63288-plugin-1.0.bin bootflash:gplug_copy
- Copy the copy of the gplug to standby supervisor as well
copy bootflash:gplug_copy bootflash://sup-remote/
- Load the gplug on active supervisor
load bootflash:gplug_copy
- Attach to standby supervisor
attach module <standby-sup-slot>
- Load gplug on standby supervisor
load bootflash:gplug_copy
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered customer and you must be logged in.
DDTS Description CSCtc48338 (registered customers only) Executing any of the following commands on a MDS switch or collecting the same information via Fabric Manager/device manager may cause a kernel panic on the supervisor:
show hardware internal mgmt0 stats
show hardware internal eobc stats
show tech-support
tac-pacIn a dual supervisor switch this will force a supervisor switchover. In single supervisor systems the switch will reload.