Revised August 11, 2005
August 4, 2005
Products Affected
-
15454 - 15454-TCC2=
Problem Description
In less than 0.02% of cases, a MFGMEM alarm is raised incorrectly against the backplane (BP) on an ONS 15454 node using the 15454-SA-HD (high density) or 15454-SA-ANSI chassis with TCC2 cards. The alarm is raised due to the inability of the TCC2 card to correctly read the EEPROM. In Release 5.0.2, when using the TCC2 in combination with the 15454-SA-HD, and the DS3/EC1-48 card, failure of the TCC2 to correctly read the EEPROM can cause a loss of traffic.
This issue has not been seen with the TCC/TCC+/TCC2P
Background
The scenario can occur because, while using the ONS 15454 high density (HD) shelf, the inability to read the EEPROM correctly leads the TCC2 to incorrectly identify the shelf as an ONS 15454 ANSI shelf, and, in Release 5.0.2, when using DS3/EC1-48 cards, this may result in the DS3/EC1-48 cards being deleted from the database. This aspect of the issue only occurs in Release 5.0.2. The alarm itself is not service affecting in releases prior to Release 5.0. This issue is attributed to a failure to check and verify the correct content in the EEPROM. This issue is most likely to occur during turn-up of a new node. The issue can also occur if a new TCC2 is installed in the shelf, or during a first switchover operation. This issue can be tracked using DDTS CSCei37835.
Problem Symptoms
This issue is most likely to occur during turn-up of a new node. This issue can also occur during the first switchover operation. Less than 0.02% of nodes in this configuration are known to be affected.
Workaround/Solution
Cisco recommends upgrading to Release 5.0.4 if you deploy the DS3/EC1-48 to avoid this issue. To recover from this issue, side switch the affected TCC2 back to the protect card. If the issue persists, call the Cisco TAC. This issue is resolved in Releases 5.0.4, 5.0.5, and 6.0.
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.
|
DDTS |
Description |
|---|---|
|
CSCei37835 (registered customers only) |
EEPROM BP Failure |
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.