Introduction
This document ensures that you can provide Cisco Development Engineering with a fully operational disk set from your production environment without compromising your business operation in a Cisco Media Convergence Server (MCS)-7835-I1 or MCS-7845-I1 environment.
Note: Perform a complete back-up of your target Cisco CallManager system before you continue with this procedure.
Prerequisites
Requirements
Cisco recommends that you have knowledge of these topics:
-
Cisco Unified CallManager
-
Cisco MCS
Components Used
The information in this document is based on these software and hardware versions:
-
Cisco Unified CallManager
-
Cisco MCS-7835
-
Cisco MCS-7845
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Backup Sequence
Always start with the Publisher and complete one server at a time. Follow the correct drive removal process for the type of server used for the Publisher first, then follow with the Subscribers one at a time.
For example, if your Publisher is an MCS-7845 and all your Subscribers are MCS-7835s, follow the instructions for the MCS-7845 disk removal for the Publisher only and then follow the instructions for the MCS-7835 disk removal for your Subscribers.
MCS-7845-I1 CallManager Servers
There are two separate Redundant Array of Independent Disks (RAID) arrays on MCS-7845-I1 servers:
-
One disk in slot 0 (RAID Array A)
-
One disk in slot 1 (RAID Array A)
-
One disk in slot 2 (RAID Array B)
-
One disk in slot 3 (RAID Array B)
Complete these steps. Start with the Publisher and then repeat these steps on the Subscribers. With these steps, you check the fallback and the upgrade drives before you continue in order to ensure your fallback scenario is good.
-
Label each drive with the server name and drive slot number they are mounted in.
-
Shut down the server cleanly.
-
Partially remove one drive from each RAID array (referred to as 0 and 2 hereafter). Leave them half in their drive slots.
-
Start up the server and ensure that F5 is selected when you are prompted for HDD recovery.
-
Confirm that Windows boots fully.
-
Shut down the server cleanly.
-
Reinsert the original drives 0 and 2. Do not use replacement disks at this time.
-
Completely remove the drives that were just tested (referred to as drives 1 and 3 hereafter) from each RAID array. Be sure to label each disk with the slot number it was removed from (slots 1 or 3) and the server name.
-
Start the server and ensure that F5 is selected when you are prompted for HDD recovery.
-
Confirm that Windows boots fully.
-
Insert the new replacement disks into drive slot 1 and drive slot 3
MCS-7835-I1 CallManager Servers
There is only one RAID array on MCS-7835-I1 servers:
-
One disk in slot 0 (RAID Array A)
-
One disk in slot 1 (RAID Array A)
Complete these steps. Start with the Publisher and then repeat these steps on the Subscribers. With these steps, you check the fallback and the upgrade drives before you continue in order to ensure your fallback scenario is good.
-
Label each drive with the server name and drive slot number they are mounted in.
-
Shut down the server cleanly.
-
Partially remove the lower drive (referred to as drive 0 hereafter) from the RAID array. Leave it half in its drive slot.
-
Start the server and ensure that F5 is selected when you are prompted for HDD recovery.
-
Confirm that Windows boots fully.
-
Shut down the server cleanly.
-
Reinsert the original drive 0. Do not use replacement disks at this time.
-
Completely remove the drive that was just tested (referred to as drive 1 hereafter) from the RAID array. Be sure to label the disk with the slot number it was just removed from (slots 1) and the server name.
-
Start the server and ensure that F5 is selected when you are prompted for HDD recovery.
-
Confirm that Windows boots fully.
-
Insert the new replacement disks into drive slot 1.
NetPro Discussion Forums - Featured Conversations
| NetPro Discussion Forums - Featured Conversations for Voice |
| Service Providers: Voice over IP |
| Voice & Video: Voice over IP |
| Voice & Video: IP Telephony |
| Voice & Video: IP Phone Services for End Users |
| Voice & Video: Unified Communications |
| Voice & Video: IP Phone Services for Developers |
| Voice & Video: General |
Related Information
-
Recommended Reading:
Troubleshooting Cisco IP Telephony
- Technical Support & Documentation - Cisco Systems
| Updated: Jun 26, 2007 | Document ID: 70994 |