Q. What is the purpose of the Cisco® Redundant Power System 2300
(Cisco RPS 2300)?
A. The Cisco RPS 2300 is a redundant power system that provides users with uninterrupted network services in the event of an internal power supply failure. The Cisco RPS 2300 is used with fixed-configuration Cisco Catalyst® switches including the Cisco Catalyst 3750-E switches, and routers like the Cisco Integrated Services Routers. The Cisco RPS 2300 helps ensure failover from internal power supply failures for one or two of up to six connected switches or routers. It automatically senses when a connected device has experienced an internal power supply failure and immediately begins to supply power to the device, providing continuous uptime with no device reboot.
Q. Is the Cisco RPS 2300 the same as an uninterruptible power supply (UPS)?
A. No. A redundant power system protects network devices against internal power supply failures and failure of an AC circuit (a circuit breaker tripping, for example). A UPS protects these devices against interruption of utility power. For maximum availability, the Cisco RPS 2300 should always be used in conjunction with a UPS.
Q. Will the failover mechanism in the Cisco RPS 2300 prevent a switch reboot?
A. Yes. The Cisco RPS 2300 is designed to provide continued operation of the connected switch or router in the event of a power supply failure.
Q. How many devices can be connected to the Cisco RPS 2300?
A. Up to six devices may be connected to the Cisco RPS 2300.
Q. How many of the connected switches can be actively backed up with a single Cisco RPS 2300?
A. The number of switches actively backed up by the Cisco RPS 2300 depends on the number and capacity of power supply modules in the RPS and the types of devices they are backing up (Table 1).
Table 1. Number of Switches Actively Backed Up by the Cisco RPS 2300
Cisco RPS 2300 Power Supply Configuration
1 x 750W
2 x 750W
1 x 1150W
2 x 1150W
Cisco Catalyst 3750-E or 3560-E switches with 1150W PS
Not supported
1
1
2
All other supported network devices
1
2
1
2
Q. Can the Cisco RPS 2300 support Power-over-Ethernet (PoE) switches as well as data-only switches?
A. Yes; it supports both. However, the total power available to the switches depends on the number and capacity of power supply modules in the Cisco RPS 2300. Please refer to Table 1 for details.
Q. What switches and routers does the Cisco RPS 2300 support?
A. The following switches and routers are supported:
Q. Can the switch and the Cisco RPS 2300 be attached to separate power circuits?
A. Yes. The Cisco RPS 2300 and the switch can be on separate circuits. As long as at least one circuit is in service and providing power, the attached switch will receive power.
Operation and Installation
Q. Can we connect a running device to the RPS 2300, without service interruption?
A. Yes. You should place the RPS port in "Standby" mode, then connect the device, then place the RPS port in "Active" mode. This will prevent the device from rebooting when connected to the RPS. This is optional for the Catalyst 3750-E and Catalyst 3560-E switches.
Q. Why does a device continue to draw power from the RPS even after its internal power is restored?
A. This is expected behaviour for all devices, other than the Catalyst E series switches. The device might reboot when reverting back to its own power supply. Hence, it continues to draw power from the RPS, so that the device can be switched back to its own power supply at a convenient time. In order to switch the device back to its own power supply, place the RPS port in "Standby" mode until the device reverts back to its own power supply, then place the RPS port in "Active" mode again. The Catalyst E Series switches are capable of reverting back to their own power supplies without service interruption.
Q. Can a device revert back to its own power supply without rebooting?
A. A Catalyst E Series switch is capable of reverting back to its own power supply without rebooting. All other devices might reboot when reverting back to their own power supplies.
Q. For a Cisco RPS 2300 installed in a wiring closet, what are the recommended best practices for rack-mount placement and cable management?
A. Cisco recommends the following when rack-mounting the Cisco RPS 2300:
• Install the Cisco RPS 2300 at the bottom of the rack, before installing any other switches or routers above it.
• Connect all the RPS cables to the Cisco RPS 2300, before rack-mounting other switches or routers.
• Rack-mount all the supported switches above the Cisco RPS 2300. Leave a one-half RU space between the Cisco RPS 2300 and the switch immediately above it, to allow room for the cabling (leaving this space is not mandatory).
• Connect the RPS cable(s) to the switch above the Cisco RPS 2300, before connecting any Cisco StackWise® or StackWise Plus cables.
• The maximum RPS cable length is 4.9 ft. (1.5 meters). Take this into account while deciding on the placement of network devices in the rack. Switches or routers using the Cisco RPS 2300 should be placed closest to the RPS.
Q. What is the maximum length of the RPS cable for the Cisco RPS 2300? Is a longer RPS cable available from Cisco or other vendors?
A. The CAB-RPS2300= and CAB-RPS2300-E= are the only RPS cables that are compatible with the Cisco RPS 2300. No other RPS cables are currently recommended by Cisco for use with the RPS 2300. Both these cables are 4.9 ft. (1.5 meters) in length.
Q. On a Cisco switch or router with an RPS slot, can a cable other than a Cisco RPS cable be inserted into that slot?
A. No. This RPS slot must only be used to connect to the Cisco RPS 2300 with the appropriate Cisco RPS cable.
Q. In the event of near-simultaneous power supply failures on all the switches connected to a Cisco RPS 2300, can certain switches be configured to receive higher priority from the RPS?
A. Yes. The Cisco RPS 2300 allows users to configure DC port priorities. Cisco devices connected to the higher priority ports will fail over to the Cisco RPS 2300 first.
Q. When a Cisco Catalyst 3750-E or 3560-E Series Switch's power supply fails, is it possible to change the power supply of the switch, while it is being backed up by the Cisco RPS 2300, without affecting the flow of switched traffic?
A. Yes. It is possible to change the power supply on a Cisco Catalyst 3750-E or 3560-E being powered by the Cisco RPS 2300 without causing any switch downtime. The only exception to this is with DC power supplies like the C3K-PWR-265WDC. It is recommended the switch using a DC power supply is turned off, when changing power supplies, for safety reasons.
Q. When the failed power supply of a Cisco Catalyst 3750-E or 3560-E switch is reinstated, will the switch automatically revert back to its own power supply?
A. Yes. The Cisco RPS 2300 will detect that the switch's power supply has been reinstated and will hand off the power to the switch's supply.
Q. From a remote location, is it possible to put the Cisco RPS 2300 or individual RPS ports into active or standby mode?
A. Yes. It is possible to remotely put all or selected Cisco RPS 2300 ports in active or standby mode via the command line interface (CLI) or the Cisco Network Assistant network management tool. However, this is only possible if at least one of the Cisco RPS 2300 DC ports is connected to a Cisco Catalyst 3750-E or 3560-E Series Switch.
Q. What is the purpose of the Cisco RPS 2300 power bay insert? When should it be used?
A. The Cisco RPS 2300 power bay insert should be used at all times, when the Cisco RPS 2300 is operating with only one power supply. The insert helps ensures that the aerodynamics within the Cisco RPS 2300 will provide proper cooling. Operating the Cisco RPS 2300 without this insert in the empty power supply bay may result in serious RPS 2300 faults, due to overheating. This insert is provided with all RPS 2300s ordered with one power supply. For a Cisco RPS 2300 ordered with two power supplies, this insert is not included and needs to be ordered separately as a spare.
Management
Q. Does the Cisco RPS 2300 offer enhanced management features when connected to Cisco switches?
A. Yes. The Cisco RPS 2300 offers enhanced management capabilities when attached to Cisco Catalyst 3750-E and 3560-E Series Switches.
Q. What new management features are available on the Cisco RPS 2300?
A. Provided the Cisco RPS 2300 is connected to a Cisco Catalyst 3750-E or 3560-E Series Switch, it provides users with the following additional management features:
• The ability to remotely place the RPS (and all six DC ports) in active or standby mode.
• The ability to report if one or two RPS power supply modules are present in the Cisco RPS 2300, as well as their status.
• The ability to report a list of connected switches and their power requirements.
• The ability to report which switches are being supplied power from the Cisco RPS 2300.
• The ability to configure switch priority.
Power Supplies and Spares
Q. What power supply options are available for the Cisco RPS 2300?
A. The Cisco RPS 2300 works with the power supplies listed in Table 2. These are also compatible with Cisco Catalyst 3750-E or 3560-E Series Switches.
Table 2. Cisco RPS 2300 Power Supplies
Power Supply
Output Power
C3K-PWR-1150WAC
1150W AC
C3K-PWR-750WAC
750W AC
Q. Will the entire Cisco RPS 2300 unit need to be replaced if it experiences power supply or blower problems?
A. No. Cisco RPS 2300 users can replace the faulty power supplies or blowers. The product IDs for the spares are shown in Table 3.
Table 3. Product IDs for Individual Cisco RPS 2300 Spares
Model Number
Product Description
PWR-RPS2300
RPS 2300 chassis
C3K-PWR-1150WAC
Catalyst 3750-E/3560-E 1150W AC power supply
C3K-PWR-750WAC
Catalyst 3750-E/3560-E 750W AC power supply
BLWR-RPS2300=
Spare 45CFM Blower for Cisco Redundant Power System 2300
CAB-RPS2300-E=
Spare RPS Cable RPS 2300 Cat 3750E/3560E Switches
CAB-RPS2300=
Spare RPS Cable for Cisco Redundant Power System 2300
BLNK-RPS2300=
Spare Bay Insert for Cisco Redundant Power System 2300
ACC-RPS2300=
Spare Accessory Kit for Cisco Redundant Power System 2300
Table 4. Cisco SMARTnet® maintenance contracts for the Cisco RPS 2300
Model Number
Product Description
CON-SNT-RPS2300
SMARTnet 8x5xNext Business Day Advance Replacement Service
CON-SNTE-RPS2300
SMARTnet 8x5x4hr Advance Replacement Service
CON-SNTP-RPS2300
SMARTnet 24x7x4hr Advance Replacement Service
CON-S2P-RPS2300
SMARTnet 24x7x2hr Advance Replacement Service
CON-OS-RPS2300
SMARTnet 8x5xNext Business Day Onsite Replacement Service
Q. Can the power supply modules used for the Cisco RPS 2300 be re-used in other Cisco networking devices?
A. The Cisco RPS 2300 power supplies are compatible with the power supplies found in the Cisco Catalyst 3750-E and 3560-E Series.
Q. Why are there two different RPS cable options when ordering a Cisco RPS 2300 on Cisco.com?
A. There are two RPS cables available for the Cisco RPS 2300. Both of them have a 22-pin connector on the RPS end. However, there are two connector varieties on the switch end. There is a 22-pin connector for Cisco Catalyst 3750-E or 3560-E Series Switches (CAB-RPS2300-E=); this connector facilitates the additional management capabilities available with these switches. A 14-pin connector is available for all other switches and routers (CAB-RPS2300=).
For More Information
For more information about the Cisco RPS 2300 contact your local account representative.