This chapter provides general reference information to help you understand how to operate the Cisco Billing and Measurements Server (BAMS) using Man-Machine Language (MML) commands. See Chapter 5, "Using BAMS Tag IDs" for the information about the tag IDs that you use in conjunction with MML commands to modify BAMS tables.
Note MML commands are differentiated from the surrounding text by being set in a Courier typeface. This makes them appear as they would on a computer screen. User input is shown in a bold font, and system responses are shown in a plain font. Text strings that you enter with MML commands are enclosed in quotes. Integers are shown without quotes.
Command Notation
The command notation follows the Backus-Naur conventions.
Command Syntax
The command syntax follows the Bellcore TL1 conventions.
Starting and Stopping BAMS
The following sections describe the system-level MML commands that you use to start and stop BAMS.
Starting the System
To start the system from the MML system prompt, use the sta-softw (start software) command.
Example:
sta-softw
or
start_system (from UNIX)
Stopping the System or OOS
To stop the system or bring it out-of-service (OOS), use the stp-softw (stop software) command.
Example:
stp-softw::confirm
or stop_system (from UNIX)
Starting an MML Session
To start an MML session, and to get information about MML commands, perform the following steps:
Step 1 Log in to BAMS using your user ID and password.
When MML is started, the system prompt changes to mml:sys>.
The system is now ready to accept command-line instructions.
Note This is an alternate method for starting the command-line interface: In the BAMS bin directory, type mml in lowercase letters at the UNIX system prompt. Certain environment variables must be defined before MML can run. To define these variables, run . sym_defs in the profile of authorized users. The UNIX prompts and scripts follow the conventions for the UNIX Korn shell.
Step 2 Type help.
The system displays a list of available MML commands. One screen of information is presented. Press Enter to display additional information.
These MML commands are discussed in more detail in the following sections.
Help—Help Command
Purpose
Displays a list of available commands or help on a specified command.
Format
help[:commandname]
Description
The Help function provides syntax and other general command information. At the node level, the Help function provides command information for the current node. At the system level, the Help function provides command information for the system as a whole, as well as for each node.
Example
mml:sys>help
Billing and Measurements Server - BAMS-00 2004-09-22 15:28:46
Available commands (in alphabetical order):
<command name>:?: Displays a list of possible tagIDs
<command name>:<tagID>:? Displays a list of possible field names
Starts a provisioning session. <dirname>=active | default | new | dirname
prov-stp::[force] Stops the current provisioning session
prov-sync:: Copies active parameters from the current unit to the remote unit
quit Quit the session
r::[n] Executes a previously entered command
rtrv-alms Displays the active alarms
rtrv-circuit:<all>:<trunkgrp>="nnn"> Displays number of circuits/trunkgrp
rtrv-configs Displays available configurations
rtrv-file::<file name> Displays the contents of a Unix text file
rtrv-ne Displays attributes of the Network Element
rtrv-session Displays the current session
rtrv-softw:<process name>|all Displays the status of system modules
rtrv-syslog::[cont] Displays syslog continuously
set-alm:taskname:msgnumber="<nnn>",level=<n>
Generates an alarm message level n can be 0 | 1 | 2
set-node:<node #>|<node_name>|sys: Sets node number
set-nodename::name=<node name> Sets the nodename of a node
sw-ovr Forces a manual rotation
Note Variables such as tag ID, field name, and so on, are shown in brackets.
Note Strings must be enclosed in quotes, for example "string". Anything enclosed in brackets, for example [:command name] is an option. Colons are used to separate major command components, for example the command name from the tag ID, and the tag ID from the field name. Fields are separated by commas. When modifying field name values, do not enter spaces before or after the equal sign (=) or commas.
command name:?:—Help on Tag IDs
Purpose
Displays a list of tag IDs that can be used with the specified MML command.
Format
command name:?:
Description
The value of command name is any valid MMLcommand.
Type help to display a list of available commands.
Example
mml:sys>prov-add:?:
Billing and Measurements Server - BAMS-00 2004-09-22 11:33:04
B COMPLD
ALM-PARMS
MSC-PARMS
MSC-THRES
;
Note In the preceding example, the specified command displays three valid tag IDs at the system level prompt. When a node is set, the tag IDs are displayed, as shown in the example below:
mml:1:boston>prov-add:?: Billing and Measurements Server - BAMS-00 2004-09-22 11:26:35 B COMPLD ZONE-INFO TRUNKGRP ALM-PARMS BIN1110 COUNTRY MAPTYPE NODEPARMS NPANXX P01FILTER POLL RATING-TYPE RATE-EXC SIGPATH SKIPCDB SKIPCDE SWITCHINFO TCA-TBL TOLLFREE TKGPREFIX ;
command name:tagID:?—Help on Field Names
Purpose
Obtains a list of field names for a specified table.
Format
command name:tagID:?
Description
The value of command name is any valid MML command.
The value of tag ID is any valid tag ID.
Type command name:?to obtain a listing of valid tag IDs.
Example
mml:sys>prov-add:MSC-THRES:?
Billing and Measurements Server - BAMS-00 2004-08-06 13:50:13
B COMPLD
interval (numeric)
put (numeric)
plt (numeric)
uut (numeric)
iut (numeric)
mil (numeric)
mal (numeric)
crl (numeric)
;
Note In the example above, the specified command and tag ID display the field names for the MSC-THRES table. See the "Tag IDs and Field Names" section on page 5-1 for a description of the fields in each BAMS table.
MML Session Logs
The /opt/CiscoBAMS/data/logs directory contains daily MML session logs.
The log contains the time stamp of all user activity on BAMS and can be used for audits and troubleshooting.
MML Commands
To use the Man-Machine Language (MML) commands, define your user profile by typing .sym_defs in the /opt/CiscoBAMS/bin directory. Next, type mml to start the MML program. The UNIX system prompt changes to mml:sys> and allows you to enter MML commands, which are listed in the following sections.
chgno—Change Number
Purpose
Changes the polling sequence numbers
Format
chgno::[seqno1=#],[seqno2=#]
Description
The value of seqno1 is the value of the first polling sequence number.
The value of seqno2 is the value of the second polling sequence number.
Note This command can be executed only at the node level.
Example
mml:3>chgno::seqno1=1,seqno2=1
Billing and Measurements Server - BAMS-00 2004-09-08 14:11:09
B COMPLD
;
clr-alm—Clear Alarm
Purpose
Clears a previously set alarm that was written to the alarm history file. These alarms are generally set for test purposes, for example, to test the alarm trapping. This command sends an alarm trap clear to the SNMP agent. (For details about setting alarms, see the "set-alm—Set Alarm" section.)
The value of taskname is any valid BAMS task name.
The value of msgnumber can be any three-digit number. This number corresponds to the number of the message to be cleared. For ACC227 and POL402 alarms, you need to specify the full msgtext value to clear the alarm, because the message text for these alarms can vary. For ACC227, the msgtext includes the timestamp.
Example
mml:3>clr-alm:MSC:msgnumber="030"
mml:3>clr-alm:POL:msgnumber="402",msgtext="Cannot connect to unit
bams0-a"
mml:3>clr-alm:ACC:msgnumber="227",msgtext="TTL CALL ROUTING III, TG1, 0
is equal to 0 @ 20021102220000 UTC"
Billing and Measurements Server - BAMS-00 2004-09-08 14:11:09
The value of filename is a UNIX filename. This command is used to create a special log file that is stored in the /opt/CiscoBAMS/files/mml directory in the format filename.dlog when you quit MML. This log is different from the MML daily session log files stored in the /opt/CiscoBAMS/data/log/mml directory, which are prefixed with "mml."
Example
mml:sys>dialog:test:
Billing and Measurements Server - BAMS-00 2004-09-08 09:37:30
B COMPLD
;
get-nodenames—Get Node Names
Purpose
Lists all node names.
Format
get-nodenames::
Description
Displays a list of all defined node names. The system default values for the node names are node01, node02, ... node08.
Example
mml:sys>get-nodenames::
Billing and Measurements Server - BAMS-00 2004-09-15 17:47:37
node 1: "newyork"
node 2: "sanfrancisco"
node 3: "baltimore"
node 4: "richmond"
node 5: "washingtondc"
node 6: ""
node 7: "miami"
node 8: ""
h—History
Purpose
Displays commands in the history buffer.
Format
h::[number[,number]]
Description
The value of number is a numeric value. h:: is equivalent to h::1,15, which displays the last 15 commands in the history buffer. The first number option represents the nth command in the history list. The second number represents the number of commands in the list (a maximum of 15).
Example
mml:sys>h::1
Billing and Measurements Server - BAMS-00 2004-09-08 09:40:38
B COMPLD
1 h::1
;
prov-add—Provision Add
Purpose
Adds a new record to the table specified by the tag ID.
Format
prov-add:tagID:field name1=["]value1["], ... field
nameN=["]valueN["][range1 - range2]
Description
The value of tagID is any valid tag ID.
The value of field name1 is a first field name.
The value of value1 is a first value.
The value of field nameN is an Nth field name.
The value of valueN is an Nth value.
The value of range1 is a first value of a desired field range.
The value of range2 is a second value of a desired field range.
Billing and Measurements Server - BAMS-00 2004-09-08 11:06:53
B COMPLD
"SIGPATH"
;
prov-cpy—Provision Copy
Purpose
Copies a table or tables from one node to the current node.
Format
prov-cpy:[<tagid>|all]:srcnode=<1..8> | <nodename>,srcver=active |
default | new | <dirname>
Description
The value of tagID is any valid tag ID.
The value of srcnode is a node identifier (1 through 8).
The value of nodename must be a valid UNIX filename because this name is used to create a directory link in the /data directory.
The value of srcver is one of the following:
•Active—Use this value to copy the table from the source node's active configuration.
•Default—Use this value to copy the table from the source node's default configuration. This could be used if the prov-sta command does not use the srcver=default setting. In this case, use prov-cpy to copy the default table for one table only.
•New—Use this value to empty the table. This could be used if the prov-sta command does not use srcver=new. In this case, use prov-cpy to copy an empty table into the current session.
The value of dirname specifies that the table is copied from the source node's MML directory. This is the same as the prov-sta command's dstver argument.
Example
mml:sys>set-node:2:
Billing and Measurements Server - BAMS-00 2004-09-26 18:19:04
Billing and Measurements Server - BAMS-00 2004-09-26 18:23:06
B COMPLD
/* The measurements interval (interval-minutes) has been modified in
the NODEPARMS table. */
/* This node will be dynamically restarted for the local unit if it
is currently running. */ ;
prov-diff—Provision Compare
Purpose
Compares active parameters between BAMS units.
Format
prov-diff::
Description
No variables need to be specified.
Example
mml:sys>prov-diff::
Billing and Measurements Server - BAMS-00 2004-09-21 17:38:28
B COMPLD
/* Table ALM-PARMS matches for both BAMS units */
/* Table MSC-PARMS matches for both BAMS units */
/* Table MSC-THRES matches for both BAMS units */
;
mml:sys>set-node:1:
Billing and Measurements Server - BAMS-00 2004-09-21 09:45:20
B COMPLD
;
mml:1:node01>prov-diff::
Billing and Measurements Server - BAMS-00 2004-09-21 09:45:24
B COMPLD
/* Table ZONE-INFO matches for both BAMS units */
/* Table TRUNKGRP matches for both BAMS units */
/* Table ALM-PARMS matches for both BAMS units */
/* Table BIN1110 matches for both BAMS units */
/* Table COUNTRY matches for both BAMS units */
/* Table MAPTYPE matches for both BAMS units */
/* Table NODEPARMS matches for both BAMS units */
/* Table NPANXX matches for both BAMS units */
/* Table P01FILTER matches for both BAMS units */
/* Table POLL matches for both BAMS units */
/* Table RATING-TYPE matches for both BAMS units */
/* Table RATE-EXC matches for both BAMS units */
/* Table SIGPATH matches for both BAMS units */
/* Table SKIPCDB matches for both BAMS units */
/* Table SKIPCDE matches for both BAMS units */
/* Table SWITCHINFO matches for both BAMS units */
/* Table TCA-TBL matches for both BAMS units */
/* Table TOLLFREE matches for both BAMS units */
/* Table TKGPREFIX matches for both BAMS units */
;
Note If two (or more) tables are not identical across units, you will receive a message similar to the following:
/* Table <table name> DOES NOT MATCH across BAMS units. Examine this table on both BAMS units. Execute prov-sync from correct unit. */
After you determine which BAMS unit has the correctly configured table, execute the prov-sync command for the appropriate node of the correctly configured BAMS unit. For more information, see "prov-sync—Provision Synchronize" section.
prov-dlt—Provision Delete
Purpose
Deletes a record from the table specified by the tag ID.
Format
prov-dlt:tagID:field name1=["]value1["], ... field
nameN=["]valueN["][range1-range2]
Description
The value of tagID is any valid tag ID.
The value of field name1 is a first field name.
The value of value1 is a first value.
The value of fieldnameN is an Nth field name.
The value of valueN is an Nth value.
The value of range1 is a first value of a desired field range.
The value of range2 is a second value of a desired field range.
Billing and Measurements Server - BAMS-00 2004-09-08 11:25:03
B COMPLD
"SIGPATH"
;
prov-dply—Provision Deploy
Purpose
Implements changes specified during an active provisioning session.
Format
prov-dply::[srcver=dirname]
Description
The value of dirname is the directory name; if you are in a provisioning session, you can deploy another session from within the active directory. prov-dply:: copies the changes in the current provisioning session to the active session (directory). If a directory name is specified with the prov-dply command, the files in that directory are copied to the active session.
Note When you execute a prov-dply command in a redundant BAMS configuration, all the tables at the same level (node or system) are synchronized with the remote unit (i.e., they are transferred to that unit). This is the same behavior as when you execute the prov-sync command. The following message indicates that an MML table has been successfully transferred to the remote BAMS unit:
/* Transferring file <filename> ... */
If an SXF error message is displayed instead, the MML tables may not be synchronized if this table was edited in this session. For more information, refer to the specific message in the "Send File Transfer Task Messages" section on page A-64.
Example
mml:2>prov-dply::srcver=test
Billing and Measurements Server - BAMS-00 2004-09-08 11:29:15
B COMPLD
;
Note When you execute prov-dply at the node level, if the values to be provisioned for the NODEPARMS parameters nailed-cfg and interval-minutes are different from those in the current active configuration, the processing tasks for this node automatically restart so that these parameter changes can take effect. The restart of the node tasks generates MGR801 alarms, which indicate that certain processes are being terminated and restarted. Since changing these parameters has a significant effect on how the data is processed, the measurements data produced might show some incongruities with previously generated measurements data.
prov-ed—Provision Edit
Purpose
Modifies one or more provisioning records in the table specified by the tag ID.
Format
prov-ed:tagID:field name1=["]value1["], ... field
name>=["]valueN["][range1-range2]
Description
The value of tagID is any valid tag ID.
The value of field name1 is a first field name.
The value of value1 is a first value.
The value of fieldnameN is an Nth field name.
The value of valueN is an Nth value.
The value of range1 is a first value of a desired field range.
The value of range2 is a second value of a desired field range.
Note Execute the prov-rtrv command first, to see the existing configuration.
Billing and Measurements Server - BAMS-00 2004-09-08 11:33:47
B COMPLD
"SIGPATH"
;
prov-exp—Provision Export
Purpose
Exports a list of parameters for a specific table or all tables. The parameters are the field names and values of the table or tables.
This command can be executed at the system or node level. When executed at the system level, the command generates a file that contains all of the commands to provision the system and all of the nodes. When executed at the node level, the command generates a file that contains all of the commands to provision the indicated node.
Format
prov-exp:[tagID|all]:dirname=mml subdirectory
Description
The value of tagID is any valid tag ID.
The value of dirname is the directory name that is created under the /opt/CiscoBAMS/files/mml directory. The all option exports all tag IDs.
Example
mml:3>prov-exp:sigpath:dirname=testbackup
Billing and Measurements Server - BAMS-00 2004-09-08 11:51:11
B COMPLD
;
prov-rtrv—Provision Retrieve
Purpose
Retrieves the configuration for the specified tag ID.
Format
prov-rtrv:tagID:
Description
The value of tagID is any valid tag ID.
Example
mml:3>prov-rtrv:sigpath:
Billing and Measurements Server - BAMS-00 2004-09-08 11:54:15
B RTRV
"SIGPATH:sigpath=0x40,trunkgrp=16
"SIGPATH:sigpath=0x41,trunkgrp=16
"SIGPATH:sigpath=0x42,trunkgrp=16
"SIGPATH:sigpath=0x43,trunkgrp=16
"SIGPATH:sigpath=0x44,trunkgrp=16
"SIGPATH:sigpath=0x45,trunkgrp=16
"SIGPATH:sigpath=0x46,trunkgrp=16
"SIGPATH:sigpath=0x47,trunkgrp=16
"SIGPATH:sigpath=0x48,trunkgrp=16
"SIGPATH:sigpath=0x49,trunkgrp=16
"SIGPATH:sigpath=0x4a,trunkgrp=16
"SIGPATH:sigpath=0x4b,trunkgrp=16
"SIGPATH:sigpath=0x4c,trunkgrp=16
"SIGPATH:sigpath=0x4d,trunkgrp=16
"SIGPATH:sigpath=0x4e,trunkgrp=16
"SIGPATH:sigpath=0x4f,trunkgrp=16
"SIGPATH:sigpath=0x50,trunkgrp=16
;
prov-sta—Provision Start
Purpose
Starts a provisioning session.
Format
prov-sta::srcver=dirname,dstver=dirname[,confirm]
Description
In order to modify the contents of BAMS tables, you must execute the prov-sta command to start a provisioning session.
You specify the source of the tables to be used in the provisioning session with the srcver parameter. The value of dirname is the name of the source or destination directory. Setting srcver=new sets the configuration tables to empty. Setting srcver=default sets the configuration tables to the default values. Setting srcver=active retrieves the currently provisioned tables.
The dstver parameter defines the name of the provisioning session. This parameter creates a separate directory containing the tables for the provisioning session.
Note You must specify the confirm command option if the destination directory (dstver) already exists.
Once you start a provisioning session by executing the prov-sta command, you can modify the BAMS tables by using the MML editing commands prov-add, prov-dlt, and prov-ed, in conjunction with tag IDs.
Once all edits have been made, you execute the prov-dply command to make the tables of the provisioning session the current active tables at either the BAMS system level or node level (defined by the set-node command). If you do not wish to deploy the edited tables, use the prov-stp command to quit the provisioning session.
Billing and Measurements Server - BAMS-00 2004-09-08 14:32:49
B COMPLD
;
Note When you execute the prov-sta command, it creates a working directory with the same name as the dstver parameter value. These directories are saved so that a user can retrieve tables from this directory at a later time. (In this case the user would execute prov-sta where the srcver is the name of a previously created dstver value.) Over time, these MML working directories can accumulate if many different values are used for the dstver parameter. A maintenance script, clean_mml.sh, should be executed periodically on the BAMS unit so that the MML working directories do not use up too much disk space. This script prompts you, at the system level and for each BAMS node, to delete an MML directory or not. The newest working directory of each node is automatically saved.
To run this script, log in as the BAMS user and execute the following:
$ clean_mml.sh
** clean_mml.sh will clean up the mml working directories. The latest
** directory for each node will automatically be saved.
** Examining mml directories in BAMS system level:
Remove directory /opt/CiscoBAMS/files/mml/bams_system ?(y/n) y
You use this command if you do not want to deploy the changes made in your provisioning session to the active session. Use the force argument to force a provisioning session to stop (that is, when you must clear a lock on a prov-sta session).
Example
mml:3>prov-stp::
Billing and Measurements Server - BAMS-00 2004-09-08 11:55:57
B COMPLD
;
prov-sync—Provision Synchronize
Purpose
Copies active parameters from the current unit to the remote unit.
Format
prov-sync::
Description
No arguments are required.
Example
mml:sys>prov-sync::
Billing and Measurements Server - BAMS-00 2004-09-08 16:56:18
Billing and Measurements Server - BAMS-00 2004-09-22 14:12:03
r—Repeat
Purpose
Executes a previously entered command.
Format
r::[n]
Description
Here n is a numeric value.
Example
mml:3>r::2
Billing and Measurements Server - BAMS-00 2004-09-08 11:58:36
B COMPLD
;
mml:3>prov-rtrv:sigpath:
Billing and Measurements Server - BAMS-00 2004-09-08 11:58:36
B RTRV
;
rtrv-alms—Retrieve Alarms
Purpose
Displays the active alarms or events at the system level (for system-level alarms) or at the node level (for node-level alarms).
Format
rtrv-alms
Description
This command retrieves only clearable alarms currently maintained in the alarm history file and defined with the alarmslist configuration. It does not retrieve event information generated, for example, by table lookup and other configuration errors. No tag IDs are required, just the command verb.
Example
mml:3>rtrv-alms
Billing and Measurements Server - BAMS-00 2004-09-08 13:20:09
B RTRV
08/05/04 13:20:03 *C MSC030: Alarm/Event test message
;
B COMPLD
;
rtrv-circuit—Retrieve Circuits
This command is only available at node level, and only on systems that have been configured in PGW Dynamic Mode (i.e., where PGW_DYNAMIC_UPDATE=TRUE). For more information, see the "Setting the PGW Dynamic Update Mode" section on page 2-20.
Purpose
Displays the available circuits (at node level).
Format
rtrv-circuit
Description
No tag IDs are required, just the command verb.
Example
mml:1:node01>rtrv-circuit:all:
Billing and Measurements Server - BAMS-00 2004-09-28 15:43:36
B RTRV
"CKTS:trunkgrp=1,circuits=124"
"CKTS:trunkgrp=2,circuits=124"
"CKTS:trunkgrp=3,circuits=124"
"CKTS:trunkgrp=4,circuits=96"
"CKTS:trunkgrp=5,circuits=96"
"CKTS:trunkgrp=6,circuits=96"
"CKTS:trunkgrp=7,circuits=96"
"CKTS:trunkgrp=8,circuits=96"
;
mml:1:node01>rtrv-circuit::trunkgrp="2"
Billing and Measurements Server - BAMS-00 2004-09-28 15:43:43
B RTRV
"CKTS:trunkgrp=2,circuits=124"
;
mml:1:node01>rtrv-circuit::trunkgrp=7
Billing and Measurements Server - BAMS-00 2004-09-28 15:43:48
B RTRV
"CKTS:trunkgrp=7,circuits=96"
;
rtrv-configs—Retrieve Configuration
Purpose
Displays the available configurations.
Format
rtrv-configs
Description
The configurations are maintained in the /opt/CiscoBAMS/files/mml subdirectory. When you start a provisioning session, your changes are written to this directory. You can use this command to retrieve the current configuration. No tag IDs are required, just the command verb.
Example
mml:3>rtrv-configs
Billing and Measurements Server - BAMS-00 2004-09-12 13:23:08
The value of filename is any existing filename. You need to specify the full UNIX filename that includes the directory path, unless the file exists in the current directory (/opt/CiscoBAMS/bin).
Example
mml:sys>rtrv-file::collect_defs
Billing and Measurements Server - BAMS-00 2004-09-08 13:42:53
B RTRV
#
# Collection variables
#
REDUNDANCY_MODE=1; export REDUNDANCY_MODE
;
rtrv-ne—Retrieve Network
Purpose
Displays attributes (for example, polling status) of the network elements.
Note There is an 8-second interval between system start and POL task start. Within this interval, the status shows ACTIVE or STANDBY, even though the POL task has not started. Once the POL task starts, the polling status is accurate.
Format
rtrv-ne
Description
No tag IDs are required, just the command verb.
Example
mml:sys>rtrv-ne
Billing and Measurements Server - BAMS-00 2004-10-07 11:15:03
B RTRV
"Type: BAMS"
"Hardware platform: sun4u sparc SUNW,Ultra-250"
"Vendor: "Cisco Systems, Inc.""
"Location: Billing and Measurements Server - BAMS-00"
"Version: "3.20""
"System Status: OOS"
"Polling Status[s01 (test01)]: OOS"
"s01 (test01) Node Status: ACTIVATED"
"Polling Status[s02 (test02)]: OOS"
"s02 (test02) Node Status: ACTIVATED"
"Polling Status[s03 (node03)]: OOS"
"s03 (node03) Node Status: DEACTIVATED"
"Polling Status[s04 (node04)]: OOS"
"s04 (node04) Node Status: DEACTIVATED"
"Polling Status[s05 (node05)]: OOS"
"s05 (node05) Node Status: DEACTIVATED"
"Polling Status[s06 (node06)]: OOS"
"s06 (node06) Node Status: DEACTIVATED"
"Polling Status[s07 (node07)]: OOS"
"s07 (node07) Node Status: DEACTIVATED"
"Polling Status[s08 (node08)]: OOS"
"s08 (node08) Node Status: DEACTIVATED"
"Local hostname: "
"Unit ID: BAMS-00"
"BAMS-00 hostname: "
"BAMS-01 hostname: "
"Mode: Simplex"
;
Example
mml:node01>rtrv-ne
Billing and Measurements Server - BAMS-00 2004-09-06 14:43:17
B RTRV
"Type: BAMS"
"Hardware platform: sun4u sparc SUNW,Ultra250"
"Vendor: "Cisco Systems, Inc.""
"Location: Billing and Measurements Server - BAMS-00"
"Version: "3.20""
"Polling Status[s01 (node01)]: OOS"
"s02 (node02) Node Status: ACTIVATED"
"VSC1 seqno: 000001"
"VSC2 seqno: 000001"
"Local hostname: "
"Unit ID: BAMS-00"
"BAMS-00 hostname: "
"BAMS-01 hostname: "
"Measurement Interval: 10 minutes"
"VSC Configuration: Switched"
;
rtrv-session—Retrieve Session
Purpose
Displays the current provisioning session.
Format
rtrv-session
Description
No tag IDs are required, just the command verb.
Example
mml:3>rtrv-session
Billing and Measurements Server - BAMS-00 2004-09-08 13:56:52
B COMPLD
/* Current Session: active */
;
rtrv-softw—Retrieve Software
Purpose
Displays the status of software processes.
Format
rtrv-softw:[process name|all]
Description
The value of process name is any valid task name.
Example
mml:3>rtrv-softw:all
Billing and Measurements Server - BAMS-00 2004-08-06 14:45:00
B RTRV
"MGR-03 RUNNING"
"ALM-03 RUNNING"
"POL-03 RUNNING"
"FMT-03 RUNNING"
"COR-03 RUNNING"
"AGB-03 RUNNING"
"ASC-03 RUNNING"
"EXT-03 RUNNING"
"CTB-03 RUNNING"
"P01-03 RUNNING"
"NIC-03 RUNNING"
"BIN-03 RUNNING"
"ACC-03 RUNNING"
B COMPLD
;
Example
mml:sys>rtrv-softw:all
Billing and Measurements Server - BAMS-00 2004-09-22 14:25:18
NODE: system
------------
B RTRV
"MGR-00 RUNNING"
"ALM-00 RUNNING"
"bamsP3MIBagt-00 RUNNING"
"NNL-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MGR-00 RUNNING"
"MSCmain-00 RUNNING"
"mscParmP3MIBagt-00 RUNNING"
"mscP3MIBagt-00 RUNNING"
"pollP3MIBagt-00 RUNNING"
"nodeParmP3MIBagt-00 RUNNING"
NODE: 1
--------
B RTRV
"MGR-01 RUNNING"
"ALM-01 RUNNING"
"POL-01 RUNNING"
"FMT-01 RUNNING"
"COR-01 RUNNING"
"AGB-01 RUNNING"
"ASC-01 RUNNING"
"EXT-01 RUNNING"
"CTB-01 RUNNING"
"P01-01 RUNNING"
"NIC-01 RUNNING"
"BIN-01 RUNNING"
"ACC-01 RUNNING"
B COMPLD
rtrv-syslog—Retrieve Syslog
Purpose
Displays the system log (syslog) continuously.
Format
rtrv-syslog::[cont]
Description
No tag IDs are required, just the command verb.
Note The cont command option displays the system log continuously. Press Ctrl-C to escape out of the display.
Example
mml:sys>rtrv-syslog::
Billing and Measurements Server - BAMS-00 2004-09-08 17:22:39
08/06/04 23:35:51 MSC233: Executing system command: '/opt/CiscoBAMS/bin/msc_
08/06/04 23:35:51 MSC233:+pre_del.sh ebaf*'
08/06/04 23:35:51 MSC233: Executing system command: '/opt/CiscoBAMS/bin/msc_
08/06/04 23:35:51 MSC233:+pre_del.sh ext*csv'
08/06/04 23:35:51 MSC233: Executing system command: '/opt/CiscoBAMS/bin/msc_
08/06/04 23:35:51 MSC906: Inodes matching path(s) and prefix(es) in partitio
08/06/04 23:35:51 MSC906:+n /opt: 28
08/06/04 23:45:50 MSC001: MSC version W3.02 (CISCO) cleaning disk
set-alm—Set Alarm
Purpose
Generates an alarm message. Use this command to set a test alarm that is written to the syslog. (For details about clearing alarms, see the "clr-alm—Clear Alarm" section.)
Format
set-alm:taskname:msgnumber=nnn,level=n
Description
The value of taskname is any valid BAMS task name.
The value of nnn is a three-character message number.
The value of n is a valid single-character threshold level (0, 1, or 2).
Note This command works only for alarms maintained in the alarmslist.CTL file in the /opt/CiscoBAMS/files directory.
Example
mml:3>set-alm:MSC:msgnumber="030",level=0
Billing and Measurements Server - BAMS-00 2004-09-08 14:13:13
B COMPLD
;
set-node—Set Node
Purpose
Sets the node number. Use this command to change from the system level to the node level, or to change from one node to another node.
Format
set-node:node#|nodename|sys:
Description
The value of node# is any integer between 1 and 8.
The value of nodename is any valid node name.
sys displays the system level.
Note When 1 is specified as the node number, the MML prompt changes from mml:sys> to mml:1>. Exit out of any provisioning sessions before changing the node number. The prompt displays the node name when it is defined. The prompt always displays the node number, except when system is specified.
Example
mml:sys>set-node:1:
Billing and Measurements Server - BAMS-00 2004-09-08 14:45:27
mml:1:node01>
set-nodename—Set Node Name
Purpose
Sets the node name for a node.
Format
set-nodename:node#:name=nodename
Description
The value of node# is any integer between 1 and 8.
The value of nodename must be a valid UNIX filename, because this name is used to create a directory link in the data directory. The maximum length of nodename is 40 characters.
This command must be executed within an MML editing session at the node level.
Note You can use the set-nodename command to modify any existing node names. You cannot use the command to modify the system name.
Example
mml:sys>set-nodename:1:name="boston"
Billing and Measurements Server - BAMS-00 2004-09-08 14:45:27
mml:1>
sta-softw—Start Software
Purpose
Starts the system application.
Format
sta-softw
Description
No tag IDs are required, just the command verb.
Note An alternative way to start the software is to use the UNIX start_system command, which is found in the /opt/CiscoBAMS/bin directory.
Example
mml:sys>sta-softw
Billing and Measurements Server - BAMS-00 2004-09-08 14:14:41
B COMPLD
;
stp-softw—Stop Software
Purpose
Stops the system application.
Format
stp-softw::confirm
Description
No tag IDs are required, just the command verb.
Note You can execute this command only at the system level.
Note An alternative way to stop the software is to use the UNIX stop_system command, which is found in the /opt/CiscoBAMS/bin directory.
Example
mml:sys>stp-softw::confirm
Billing and Measurements Server - BAMS-00 2004-09-08 14:16:34
B COMPLD
Terminating BAMS
waiting for MGR to shut down...
;
sw-ovr—Switch Over
Purpose
Forces a manual rotation of the BAMS unit designated to poll the VSC. (You can execute this command only on the active polling unit.)
Format
sw-ovr
Description
You can use the sw-ovr command to rotate polling from the active BAMS unit to the standby unit in the event of a switch failover. The command is executed immediately on the local BAMS unit. On the remote BAMS unit, the rotation takes effect at the next poll attempt. Poll attempts are typically set at 5-minute intervals.
Caution Do not execute this command while polling is taking place; it will fail.