Feedback
|
Table Of Contents
Environmental Specifications for the Cisco UCS Equipment
Physical Specifications for the Cisco UCS Equipment
Power Specifications for the Cisco UCS 5108 Blade Server Chassis Power Supply Units
Power Specifications for the Cisco UCS 6100 Fabric Interconnects
Power Specifications for the Cisco UCS 6200 Fabric Interconnects
Power Supply Configuration Modes
Blade Server Chassis and Fabric Interconnect Clearances
Technical Specifications
This chapter describes the technical specifications for the Cisco UCS components and includes these sections:
•
Environmental Specifications for the Cisco UCS Equipment
•
Physical Specifications for the Cisco UCS Equipment
•
Blade Server Chassis and Fabric Interconnect Clearances
•
Facility Cooling Requirements
Environmental Specifications for the Cisco UCS Equipment
For the environmental specifications of the Cisco UCS 5108 Blade Server Chassis, see Table 3-1. For the environmental specifications of the Cisco UCS 6100 Fabric Interconnect, see Table 3-2.
Table 3-1 Environmental Specifications for the Cisco UCS 5108 Blade Chassis
Description Cisco UCS 5108 Blade ChassisTemperature
•
Operating
–
0 to 10,000 feet (0 to 3000 m)
–
Above 10,000 feet (3,000 m)
50 to 95ºF (10 to 35ºC)
Subtract 1ºC (1.8ºF) for each 1000 feet above 10,000 feet
•
Nonoperating
–
0 to 40,000 feet (0 to 12,190 m)
-40 to 149ºF (-40 to 65ºC)
Relative humidity (noncondensing)
10 to 90%
Noise (Sound power levels1 )
83 dBA at normal operating conditions
1 Based on ISO 3744.
Table 3-2 Environmental Specifications for the Cisco UCS 6100 Series or
UCS 6200 Series Fabric Interconnect Description Cisco UCS 6100 Fabric InterconnectTemperature
•
Operating
–
0 to 10,000 feet (0 to 3000 m)
–
Above 10,000 feet (3,000 m)
50 to 95ºF (10 to 35ºC)
Subtract 1ºC (1.8ºF) for each 1000 feet above 10,000 feet
•
Nonoperating
–
0 to 40,000 feet (0 to 12,190 m)
-40 to 149ºF (-40 to 65ºC)
Relative humidity (noncondensing)
10 to 90%
Noise (Sound pressure levels1 )
68 dBA at normal operating conditions
1 Based on ISO 7779.
Physical Specifications for the Cisco UCS Equipment
The Cisco UCS 5108 Blade Server Chassis ships in a package that includes the following components:
•
One blade chassis
•
Up to eight half-width or four full-width blade servers
•
Up to two fabric extenders
•
Eight fan modules
•
Up to four AC or DC power supply units
•
Accessory kit
•
Blanking panels for any chassis slots not filled with blade servers, fabric extenders, or power supply units
The Cisco UCS 6100 Series Fabric Interconnect ships in a package that includes the following components:
•
One fabric interconnect chassis
•
One expansion module
•
Up to two power supply units
•
Two fan modules
•
Accessory kit
•
Blanking panels for any power supply slot not filled
The Cisco UCS 6200 Series Fabric Interconnect ships in a package that includes the following components:
•
One fabric interconnect chassis
•
One expansion module
•
Up to two power supply units
•
Two fan modules
•
Accessory kit
•
Blanking panels for any power supply slot not filled
For the size of the packages containing these systems, see Table 3-3. For the sizes of these chassis after they are unpacked and ready to install, see Table 3-4.
Table 3-4 lists the physical specifications for the unpacked Cisco UCS equipment.
For the weights and quantities for each type of Cisco UCS equipment, see Table 3-5 for the Cisco UCS 5108 Blade Server Chassis Series and see Table 3-6 for the Cisco 6100 Fabric Interconnect. These tables do not include weights for the rack that holds the Cisco UCS equipment or the interface and power cables. For those weights, see the documentation provided by the manufacturers of those components.
Table 3-5 Weights and Quantities for the Cisco UCS 5108 Blade Server Chassis Components
Component Weight per Unit QuantityChassis (empty)
90 lbs. (40.8 kg)
1
B200 Blade Server
13.5 lbs (6.1 kg) 1
1 to 8
B230 Blade Server
18.0 lbs (8.16 kg) 1
1 to 8
B250 Blade Server
25 lbs (11.34 kg) 1
1 to 4
B440 Blade Server
34.5 lbs (15.65 kg) 1
1 to 4
Fabric Extender
2.5 lbs. (1.1 kg)
1 or 2
Power distribution unit
5 lbs. (2.3 kg)
1
Fan module
1.8 lbs. (0.8 kg)
8
Hard disk drive module
0.8 lbs. (0.4 kg)
2 per blade server
Power supply unit
7 lbs. (3.2 kg)
1 to 4
1 The system weight listed here is an estimate for a fully configured system and will vary depending on peripheral devices installed.
Power Specifications
The Cisco UCS Blade Server Chassis and Cisco UCS Fabric Interconnect use different power supply units. You can find their specifications in the following sections:
•
Power Specifications for the Cisco UCS 5108 Blade Server Chassis Power Supply Units
•
Power Specifications for the Cisco UCS 6100 Fabric Interconnects
Power Specifications for the Cisco UCS 5108 Blade Server Chassis Power Supply Units
To determine the number of power supply units needed for the blade server, remember that each single slot server is budgeted a max 550 W and each full width server is budgeted a max 1100 W. For a more detailed estimate, contact Cisco Sales. Table 3-9 lists the specifications for each Cisco UCS chassis AC power supply. Table 3-10 lists the specifications for each Cisco UCS chassis DC power supply.
DC wiring must meet your local codes and regulations, we recommend using a licensed local electrician to install the DC wiring needed.
The AC power supply connector on the blade server chassis is an IEC 320 C20 socket. The power cord that you use to connect the blade server power supply units to an AC power outlet will have an IEC 320 C19 plug on one end a plug on the other end that conforms to the AC power outlet specifications for your country. To determine which cord to order for your blade server chassis power supply units, see Table 3-11. When you determine which power cord you need to order, you can verify that its plugs conform to the power outlets for your facility by clicking on its reference link.
Figure 3-1 CAB-AC-16A-AUS Power Cord for the Cisco UCS 5108 Blade Server Chassis
Figure 3-2 CAB-AC-16A-CH Power Cord for the Cisco UCS 5108 Blade Server Chassis
Figure 3-3 CAB-AC-2500W-EU Power Cord for the UCS 5108 Blade Server Chassis
Figure 3-4 CAB-AC-2500W-INT Power Cord for the UCS 5108 Blade Server Chassis
Figure 3-5 CAB-AC-2500W-ISRL Power Cord for the UCS 5108 Blade Server Chassis
Figure 3-6 CAB-AC-2500W-US1 Power Cord for the UCS 5108 Blade Server Chassis
Figure 3-7 CAB-AC-C6K-TWLK Power Cord for the UCS 5108 Blade Server Chassis
Figure 3-8 CAB-C19-CBN Power Cord for the UCS 5108 Blade Server Chassis
Figure 3-9 CAB-ACS-16 Power Cord for the UCS 5108 Blade Server Chassis
Power Specifications for the Cisco UCS 6100 Fabric Interconnects
Table 3-12 lists the power supply unit specifications for the Cisco UCS 6120XP Fabric Interconnect. One power supply is required for basic operation, two power supplies provides redundancy.
Table 3-13 lists the power supply unit specifications for the Cisco UCS 6140XP Fabric Interconnect.
4
The AC power supply connector on the UCS 6100 series fabric interconnect chassis is an IEC 320 C13 socket. The power cable that you use to connect the fabric interconnect power supply units to an AC power outlet will have an IEC 320 C14 plug on one end and a plug on the other end that conforms to the AC power outlet specifications for your country. To determine which cable to order for your fabric interconnect power supply units, see Table 3-14. When you determine which power cord you need to order, you can verify that its plugs conform to the power outlets for your facility by clicking on its reference link.
Figure 3-10 SFS-250V-10A-AR Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-11 CAB-9K10A-AU Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-12 SFS-250V-10A-CN Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-13 CAB-9K10A-EU Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-14 SFS-250V-10A-ID Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-15 SFS-250V-10A-IS Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-16 CAB-9K10A-IT Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-17 CAB-AC-250V/13A Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-18 CAB-N5K6A-NA Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-19 CAB-C13-C14-JMPR Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-20 CAB-9K10A-SW Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Figure 3-21 CAB-9K10A-UK Power Cord for the Cisco UCS 6100 Series Fabric Interconnect
Power Specifications for the Cisco UCS 6200 Fabric Interconnects
Table 3-15 lists the AC power supply unit specifications for the Cisco UCS 6248 UP Fabric Interconnect. One power supply is required for basic operation, two power supplies provides redundancy.
Table 3-16 lists the DC power supply unit specifications for the Cisco UCS 6248 UP Fabric Interconnect. One power supply is required for basic operation, two power supplies provides redundancy.
Table 3-16 Specifications for the Cisco UCS 6248UP DC Power Supply (UCS-PSU-6248UP-DC=)
DC Power Supply Properties Cisco UCS 6248UP fabric interconnectMaximum output power
750 W
Input voltage
-40 to -72 VDC
DC-input current at max voltage
25 A maximum @ -40 VDC input
Efficiency
88 to 92% (50 to 100% load)
Maximum input KVA rating
820
DC input terminal block
If a replacement DC connector is needed, a Phoenix Contact part number PC 5/ 2-STF-7,62, order number 1975697 or direct equivalent. Connector information is available at:
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1975697
Output holdup time
4 ms
RoHS compliance
Yes
Hot swappable
Yes
Heat dissipation
2497 BTU/hr (750 W)
Each power supply has a separate power cord. Standard power cords or jumper power cords are available for connection to a power distribution unit having IEC 60320 C19 outlet receptacles. The jumper power cords, for use in cabinets, are available as an optional alternative to the standard power cords.
The standard power cords have an IEC C19 connector on the end that plugs into the power supplies. The optional jumper power cords have an IEC C19 connector on the end that plugs into the power supplies, and an IEC C20 connector on the end that plugs into an IEC C19 outlet receptacle.
Note
Only the regular power cords or jumper power cords provided with the chassis are supported.
Table 3-17 lists the power cords for the Cisco UCS 6200 Series Fabric Interconnect and provides their lengths in feet and meters.
AC Power Cord Illustrations
This section contains the AC power cord illustrations.
Figure 3-22 SFS-250V-10A-AR
Figure 3-23 CAB-9K10A-AU
Figure 3-24 SFS-250V-10A-CN
Figure 3-25 CAB-9K10A-EU
Figure 3-26 SFS-250V-10A-ID
Figure 3-27 SFS-250V-10A-IS
Figure 3-28 CAB-9K10A-IT
Figure 3-29 CAB-9K10A-SW
Figure 3-30 CAB-9K10A-UK
Figure 3-31 CAB-AC-250V/13A
Figure 3-32 CAB-N5K6A-NA
Figure 3-33 shows the plug connector on the optional jumper power cord for the Cisco UCS 6200 Series Fabric Interconnect. The plug plugs in to the Cisco UCS 6200 Series Fabric Interconnect power supply, while the connector plugs into the receptacle of a power distribution unit for a cabinet.
Figure 3-33 CAB-C13-C14-JMPR, Jumper Power Cord
Power Supply Configuration Modes
You can configure power modes to either use the combined power provided by the installed power supply units or to provide power redundancy when there is a power outage.
The power supplies are all operated in parallel output. You should connect two separate input sources (grids) to have the highest level of availability (grid redundancy). The system will operate on two power supplies (2+2 redundancy) for the Cisco UCS 5108 blade server chassis and one power supply (1+1 redundancy) for the Cisco UCS 6100 Series Fabric Interconnect. More detail is at:
•
http://www.cisco.com/en/US/docs/unified_computing/ucs/hw/chassis/install/overview.html#wp1245307
Blade Server Chassis and Fabric Interconnect Clearances
You must provide adequate clearance for installing the chassis, replacing modules, and allowing airflow to and from the equipment. The blade server chassis and fabric interconnect require at least 36.0 inches (91.4 cm) of clearance in front to replace a blade or a fabric interconnect. They also require at least 16 inches (40.6 cm) of clearance in back of the equipment to install and replace their components. No side clearance is required because there are no components to replace on the sides of the chassis. No clearance or empty rack units are required between the equipment.
Note
If you need more space for the mechanical lift, include the additional space with the clearance for the front of the chassis.
For the blade server chassis and fabric interconnect, the clearances for installation and replacement of components is adequate for the cooling airflow. Side clearance is not needed for installation, replacement, or airflow.
Facility Cooling Requirements
The Cisco UCS components dissipate considerable power and generate considerable heat. The major components require the following heat dissipation:
•
Cisco UCS 6120XP Fabric Interconnect dissipates up to 1534 BTUs per hour
•
Cisco UCS 6140XP Fabric Interconnect dissipates up to 2561 BTUs per hour
•
Cisco UCS 6248UP Fabric Interconnect dissipates up to 1998 BTUs per hour
•
Cisco UCS 5108 Blade Server Chassis dissipates up to 1364 BTUs per hour
•
Each Cisco B200 or B230 Blade Server dissipates up to 1347 BTUs per hour
Chassis Airflow
The Cisco UCS 5108 chassis and the Cisco UCS 6100 Series Fabric Interconnect each use front-to-back airflow for cooling, and both components are designed to work in a hot-aisle/cold-aisle environment.
Cable management can be an important factor in preventing overheating issues. In Figure 3-34, the "before" illustration shows cables blocking the rear of the chassis, and preventing the fans from exhausting warm air from the chassis. This situation causes failed DIMMs in the blade servers, and seemingly random server shutdowns when internal temperatures exceed specification. Use cable ties and other wiring practices to keep the rear of the chassis unobstructed as shown in the "after" illustration.
Figure 3-34 Cable Management