Technical Specifications

The most current technical specifications for the IE 2000 series switches can be found in the IE 2000 Data Sheet. Additional specs and detail not in the Data Sheet, are found in this section.

Enclosure Specifications

Table 14 lists enclosure specifications for the Cisco IE 2000 switches.

 

Table 14 Enclosure Specifications for the Cisco IE 2000 Switches

 
Industrial Automation and Hazardous Locations
Substation
Traffic Signal

Enclosure types

Sealed enclosures

For example: NEMA4, NEMA4X, NEMA12, NEMA13, IP54, and IP66.

Vented enclosures

For example: NEMA1, IP20, and IP21.

Fan or blower-equipped enclosures

For example: NEMA TS-2.

Note: The minimum airflow is 150 lfm1.

1 lfm = linear feet per minute.

Note:

blank.gifThe maximum ambient temperature of the IE-2000-16TC-G-X and IE-2000-16PTC-G-NX model is +65°C due to its conformal coating feature. The maximum ambient temperature of the IE-2000-16PTC-G-L, IE-2000-16PTC-G-E, and IE-2000-16PTC-G-NX model is +65°C if powering four PoE+ ports of 30 Watt each.

blank.gifThe safety certifications apply only to ambient temperatures under 140°F (60°C). However, the
Cisco IE 2000 switch can function in the substation and traffic signal installations under the environmental conditions shown in Table 14.

Alarm Ratings

Table 15 lists the alarm ratings for the Cisco IE 2000 switches.

Table 15 Alarm Input and Output Ratings

Alarm Ratings
Specification

Alarm input electrical specification

No power required—open or closed state detected.

Alarm output electrical specification

1.0 A @ 24 VDC or 0.5 A @ 48 VDC

Hazardous Locations Standards

Table 16 lists the hazardous location standards for the Cisco IE 2000 switches.

Table 16 Hazardous Locations Standards

The following standards were used for the hazardous locations approvals and certifications:

Les normes suivantes ont été appliquées pour les approbations et les certifications dans le cadre d'environnements dangereux :

ANSI/ASA 12.12.01-2013

ANSI/ASA 12.12.01-2013

CAN/CSA C22.2 No. 60079-0: 11

CAN/CSA C22.2 n° 60079-0 : 11

CAN/CSA C22.2 No. 60079-15:12

CAN/CSA C22.2 n° 60079-15 :12

CSA C22.2 No. 213-M1987

CSA C22.2 n° 213-M1987

EN 60079-0:2012

EN 60079-0:2012

EN 60079-15:2010

EN 60079-15:2010

IEC 60079-0 6th Edition

IEC 60079-0, 6e édition

IEC 60079-15 4th Edition

IEC 60079-15, 4e édition

UL 60079-0, 5th Ed, 2009-10-21

UL 60079-0, 5e éd., 21-10-2009

UL 60079-15, 3rd Ed, 2009-7-17

UL 60079-15, 3e éd., 17-07-2009