Table C-2 Supervisor Module LEDs
LED
|
Status
|
Description
|
STATUS
|
Green
|
All diagnostics pass. The module is operational (normal initialization sequence).
|
Red
|
The module has detected a slot ID parity error and will not power on or boot up.
or
The module is not fully inserted and does not have a reliable connection to the midplane.
or
The diagnostic test has failed.
|
Blinking red
|
The inlet air temperature of the system has exceeded the safe operating temperature limits of the card (a major environmental warning). The card has been shut down to prevent permanent damage. The system will be shut down after two minutes if this condition is not cleared.
or
The module is resetting, and both ejector levers are out.
|
Off
|
The module is not receiving power.
|
ID
|
Blinking blue
|
The operator has activated this LED to identify this module in the chassis.
|
Off
|
This module is not being identified.
|
SYSTEM
|
Green
|
All chassis environmental monitors are reporting okay.
|
Amber
|
At least one power supply has failed or the power supply fan has failed.
|
Red
|
The temperature of the supervisor engine major threshold has been exceeded.
|
Off
|
The slot has detected a slot ID parity error.
|
ACTIVE
|
Green
|
The supervisor module is operational and active.
|
Amber
|
The supervisor module is in standby mode.
|
PWR MGMT
|
Green
|
Sufficient power is available for all of the installed modules.
|
Amber
|
Insufficient power is available for all of the installed modules.
|
MGMT ETH
|
Green
|
The management port is operational.
|
Amber
|
The management port link has been disabled through the software.
|
Flashing Amber
|
The management port link is bad and has been disabled due to a hardware failure.
|
Off
|
The module has not detected a signal.
|
LINK
|
Green
|
The module has detected a link.
|
Off
|
The module does not detect a link.
|
ACT
|
Flashing green
|
The module is transmitting or receiving.
|
Off
|
The module is not transmitting or receiving.
|
ACT LOG FLASH
|
Green
|
The log flash CompactFlash is being accessed. Do not remove the Compact Flash until the LED is off.
|
Off
|
The expansion flash CompactFlash is not being accessed. You can remove the CompactFlash while this LED is off.
|
ACT EXPANSION FLASH
|
Green
|
The expansion flash CompactFlash is being accessed. Do not remove the Compact Flash until the LED is off.
|
Off
|
The log flash CompactFlash is not being accessed. You can remove the CompactFlash while this LED is off.
|
CMP MGMT ETH
|
Green
|
The management port is operational.
|
| |
Amber
|
The management port link has been disabled through the software.
|
| |
Flashing amber
|
The management port link is bad and has been disabled due to a hardware failure.
|
| |
Off
|
The module does not detect a signal.
|
CMP STATUS
|
Green
|
All diagnostics pass. The CMP is operational (normal initialization sequence).
|
Amber
|
Sufficient power is not available for all modules.
|
Flashing amber
|
The diagnostic test has failed.
or
The CMP is not operational because a fault has occurred during the initialization sequence.
|
Red
|
The module has detected a slot ID parity error.
|
Off
|
The CMP is not receiving power.
|
LINK
|
Green
|
The module has detected a link.
|
Off
|
The module has not detected a link.
|
ACT
|
Flashing green
|
The module is transmitting or receiving.
|
Off
|
The module is not transmitting or receiving.
|