Table Of Contents
show diagnostic interface ethernet
show fc srp initiator-wwpn-view
Show Commands
This chapter documents the following commands:
•
show diagnostic interface ethernet
•
show fc srp initiator-wwpn-view
•
show ib pm connection counter
•
show ib pm connection monitor
•
show ib-agent channel-adapter
show arp ethernet
To display entries in the Ethernet ARP routing table, enter the show arp ethernet command in User Exec mode or Privileged Exec mode.
show arp ethernet
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Ethernet read-only user.
Your Server Switch dynamically creates ARP connections on an as-needed basis and removes ARP entries from ARP routing tables when connections drop.
Table 6-1 describes the fields in the show arp ethernet command output.
Examples
The following example displays the entries in the Ethernet ARP routing table of the Server Switch.
SFS-7000P# show arp ethernet===============================================================ARP Information===============================================================port physical-address net-address type----------------------------------------------------------------------------4/1 00:05:ad:00:10:41 20.45.0.1 staticRelated Commands
show authentication
To display how your system authenticates logins, enter the show authentication command in Privileged Exec mode.
show authentication
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
General read-only user.
Use this command to determine if your Server Switch uses a RADIIUS server, along with the local database, to authenticate CLI user logins. If your Server Switch uses both resources, the command output displays the order in which your Server Switch authenticates logins.
Table 6-2 describes the fields in the show authentication command output.
Examples
The following example displays the authentication method that the Server Switch uses.
SFS-7000P# show authenticationauthentication method: local----------------------------Related Commands
show backplane
To display a breakdown of Serial Electrically Erasable and Programmable Read-Only Memory (SEEPROM) details of your Server Switch, enter the show backplane command in User Exec mode or Privileged Exec mode.
show backplane
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012
Privilege Level:
General read-only user.
The output of the show backplane command assists product support personnel.
Table 6-3 describes the fields in the show backplane command output.
Examples
The following example displays the SEEPROM details of the Server Switch backplane.
SFS-270> show backplane================================================================================Backplane Seeprom================================================================================base-mac-addr chassis-id chassis-guid--------------------------------------------------------------------------------0:5:ad:0:0:0 0x5ad000000197d 0x5ad000000197d================================================================================Backplane Seeprom================================================================================product pca pca fruserial-number serial-number number number--------------------------------------------------------------------------------0 PY-0405-00044 SFS-7000P 248show boot-config
To display the active system image that runs when your Server Switch boots, enter the show boot-config command in User Exec mode or Privileged Exec mode.
show boot-config
Syntax Description
This command has no arguments or keywords.
Defaults
No default behavior or values
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
General read-only user.
The show boot-config command displays the image that initializes chassis firmware and configures the interfaces.
This command lists the files that were used to bring up the system, the files to use the next time the system reboots, and the backup files to use in the event that the primary boot files are not available.
Table 6-4 describes the fields in the show boot-config command output.
Examples
The following example displays the image that the Server Switch boots.
SFS-7000P# show boot-config============================================================================System Boot Configuration============================================================================slot-id : 1sw-version : OS-1.1.3/build255last-image-source : OS-1.1.3/build255primary-image-source : OS-1.1.3/build255Related Commands
boot-config
install
reload
show versionshow bridge-forwarding
To display the subnets to which bridge groups forward traffic, enter the show bridge-forwarding command in User Exec mode or Privileged Exec mode.
show bridge-forwarding [integer] [subnet subnet-prefix prefix-length]
Syntax Description
Defaults
This command has no default settings.
Command Modes:
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Unrestricted read-write user.
Table 6-7 explains the fields that appear in the show bridge-subnets command output.
Examples
The following example provides sample output of the show bridge-subnets command:
SFS-7000P# show bridge-subnets================================================================================Bridge Subnets================================================================================bridge subnet-prefix subnet-prefix-len--------------------------------------------------------------------------------1 192.168.0.0 222 192.168.13.32 29Related Commands
show bridge-group
To display the attributes of bridge groups, enter the show bridge-group command in User Exec mode or Privileged Exec mode.
show bridge-group [bridge-groupID#]
Syntax Description
bridge-groupID#
(Optional) Integer value that represents a bridge group. Use the bridge-group ID number to view the attributes of one specific bridge group.
Defaults
Without an argument, the show bridge-group command shows all bridge groups.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines:
Privilege Level:
General read-only user.
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Table 6-6 describes the fields in the show bridge-group command output.
Examples
The following example (output abridged) shows all bridge groups on the Server Switch.
SFS-7000P# show bridge-group================================================================================Bridge Groups================================================================================bridge-group-id : 1bridge-group-name :eth-bridge-port : trunk 1 (not tagged)ib-bridge-port : 5/2(gw) (pkey: ff:ff)broadcast-forwarding : falsebroadcast-forwarding-mode : inherit-from-redundancy-grouploop-protection-method : onemulticast : falsemulticast-mode : inherit-from-redundancy-groupredundancy-group : 1status-in-redundancy-group : primaryRelated Commands
show bridge-subnets
To display the subnets that a particular bridge group bridges, enter the show bridge-subnets command in User Exec mode or Privileged Exec mode.
show bridge-subnets [bridge-group-number]
Syntax Description
bridge-group-number
(Optional) Limits the command output to the subnets of one particular bridge group.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Unrestricted read-write user.
Table 6-7 explains the fields that appear in the show bridge-subnets command output.
Examples
The following example provides sample output of the show bridge-subnets command:
SFS-7000P# show bridge-subnets================================================================================Bridge Subnets================================================================================bridge subnet-prefix subnet-prefix-len--------------------------------------------------------------------------------1 192.168.0.0 222 192.168.13.32 29Related Commands
show card
To display the configuration, status, and Serial Electrically Erasable and Programmable Read Only Memory (SEEPROM) details of interface cards, enter the show card command in User Exec mode or Privileged Exec mode.
show card {card-selection | all}
Syntax Description
card-selection
Card, list of cards, or range of cards to view.
all
Displays the details of all interface cards in your Server Switch.
Defaults
The show card command displays all cards by default.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
General read-only user.
•
Use the following syntax format to display the details of one card:
show card 5
•
Use the following syntax format to display the details of a list of cards:
show card 5,9,14
•
Use the following syntax format to display the details of a range of cards:
show card 5-9
•
Use the following syntax format to display the details of a list with ranges of cards:
show card 5, 7-9, 14
Table 6-8 describes the fields in the show card command output.
Note
When you run the show card command on a Cisco SFS 7008, as asterisk (*) next to the slot number identifies the controller card on which you executed this command. The asterisk does not identify the normal or standby controllers. That information appears in the "oper code" column.
Examples
To display the configuration and status information for cards 5, 9, 14, and 16:
SFS-7000P# show card 5,9,14,16============================================================================Card Information============================================================================admin oper admin oper operslot type type status status code----------------------------------------------------------------------------5 en4port1G en4port1G up up normal9 fc2port2G fc2port2G up up normal14 controller controller up up normal16 ib12port4x ib12port4x up up normal============================================================================Card Boot Information============================================================================boot boot bootslot stage status image----------------------------------------------------------------------------5 done success OS-1.1.2/build0849 done success OS-1.1.2/build08414 done success OS-1.1.2/build08416 done success OS-1.1.2/build084============================================================================Card Seeprom============================================================================product pca pca fruslot serial-number serial-number number number----------------------------------------------------------------------------5 00024 1234 95-00007-01 12349 1234 1234 95-00008-01 123414 00002 00002 95-00005-01 123416 1234 1234 95-00006-01 1234SFS-7000P#On the Cisco SFS 7008, an asterisk (*) designates the active controller card from which you have initiated your CLI session.
SFS-270# show card=========================================================================Card Information=========================================================================admin oper admin oper operslot type type status status code-------------------------------------------------------------------------11* controllerFabric12x controllerFabric12x up up normal12 controllerFabric12x controllerFabric12x up up standbyRelated Commands
action
boot-config
card
install
shutdown
typeshow card-inventory
To display the system resources and image data of interface cards, enter the show card-inventory command in User Execute mode or Privileged Execute mode.
Note
The show card-inventory command only displays cards with an oper-status of up.
show card-inventory [card-selection | all]
Syntax Description
card-selection
(Optional) Card, list of cards, or range of cards to view.
all
(Optional) Displays resources and data of all cards in the chassis.
Defaults
The show card-inventory defaults to show card-inventory all.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
General read-only user.
Each interface card is a system in itself. The following comprise system resources:
•
available and used memory
•
available and used flash memory
•
active system image on the interface card
•
CPU name and version
The active system image should match the active image that runs on the controller card. Occasions may occur when you update the system image on the controller but not on an interface card, such as when you swap interface cards between chassis or update the system image on the controller when an interface card goes down. Disk space may be an issue if you try to update the system image on the controller but cannot propagate this data to the interface card because the interface card has no free space.
The CPU description may be requested by support personnel in the event you are experience difficulties with a controller or interface card.
Table 6-9 describes the fields in the show card-inventory command output.
Examples
The following example displays the configuration and status information for the cards on the Server Switch.
SFS-7000P# show card-inventory================================================================================Card Resource/Inventory Information================================================================================slot-id : 1used-memory : 18928 (kbytes)free-memory : 108900 (kbytes)used-disk-space : 47111 (kbytes)free-disk-space : 48646 (kbytes)last-image-source : OS-2.5.0/build092primary-image-source : OS-2.5.0/build092image : OS-2.5.0/build092image : OS-2.5.0/build096cpu-descr : PPC 440GP Rev. C - Rev 4.129 (pvr 4012 0481)fpga-firmware-rev : a7pic-firmware-rev : 036036ib-firmware-rev : 00050122da (hw-rev b924 1a1)hw-rev-level : xxx <= NEWmfg-date-code : xxx <= NEWcard-part-num : xxx <= NEWcard-fru-num : xxx <= NEWuuid : xxx <= NEWguid : xxx <= NEWRelated Commands
show cdp
To display the Cisco Discovery Protocol (CDP) advertisement information, enter the show cdp command in User Exec mode or Privileged Exec mode.
show cdp
Syntax Description
This command has no arguments or keywords.
Defaults
CDP is running when the chassis boots.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Unrestricted read-write user.
The Cisco Discovery Protocol (CDP) is used to obtain protocol addresses of neighboring devices and discover the platform of those devices. Using it with the MIB database allows applications to learn the device and the SNMP agent address of neighboring devices. CDP uses the CISCO-CDP-MIB.
Each device configured for CDP sends periodic messages, known as advertisements, to a multicast address. Each device advertises at least one address at which it can receive SNMP messages. The advertisements also contain time-to-live, or holdtime, information, which indicates the length of time a receiving device should hold CDP information before discarding it. Each device also listens to the periodic CDP messages sent by others in order to learn about neighboring devices and determine when their interfaces to the media go up or down.
CDP Version-2 is the most recent release of the protocol. With CDP Version-2, detailed information is provided on the VLAN Trunking Protocol (VTP) management domain and duplex modes of neighbor devices, CDP-related counters, and VLAN IDs of connecting ports. This can help the Ethernet gateway configuration. CDP is run on server switches over both management-Ethernet and management-IB interfaces.
Examples
The following example displays the CDP advertisement informaton.
SFS-7000P# show cdp================================================================================CDP Information================================================================================run : falsemessage-interval : 60hold-time : 180device-id : SFS(00:05:ad:01:5f:f2)Related Commands
show cdp entry
show cdp neighbors
show clockshow cdp entry
To display the Cisco Discovery Protocol (CDP) information for a specific neighbor, enter the show cdp entrycommand in User Exec mode or Privileged Exec mode.
show cdp entry entry-name [protocol | version]
Syntax Description
entry-name
Specifies the entry name
protocol
(Optional) Specifies the protocol.
version
(Optional) Specifies the version
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Unrestricted read-write user.
Examples
The following example displays the CDP entry information.
SFS-7000P# show cdp entry================================================================================CDP entry================================================================================device-id : svbu-h46-c2950.svbu-h46-c2950.cisco.complatform : cisco WS-C2950T-24capabilities : switchdevice-port : FastEthernet0/1224version : Cisco Internetwork OS C2950 Software(C2950-I6Q4L2-M) Version 12.1(22)native-vlan : 230duplex : halfRelated Commands
show cdp
show cdp neighbors
show clockshow cdp neighbors
To display the information for neighbors CDP has discovered, enter the show cdp neighbors command in User Exec mode or Privileged Exec mode.
show cdp neighbors [type number] [detail]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Unrestricted read-write user.
Examples
The following example displays the CDP neighbors information.
SFS-7000P# show cdp neighbors================================================================================CDP neighbors================================================================================Capability Codes: R - Router, T - Trans Bridge, B - Source Route BridgeS - Switch, H - Host, I - IGMP, r - Repeater, P - Phonedevice-id hold-time capability platform port-id--------------------------------------------------------------------------------svbu-q8-c2950.svbu-q8-c2950.cisco.com²(- 180 S cisco WS-C2950T-24FastEthernet0/4-24Related Commands
show cdp
show cdp entry
show clockshow clock
To display the current system time, enter the show clock command in User Exec mode or Privileged Exec mode.
show clock
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Unrestricted read-write user.
If you have not set the clock, system time begins at 00:00:00, January 1, 1970.
Examples
The following example displays the clock settings of the Server Switch.
SFS-7000P# show clockMon Mar 17 02:26:32 2003 (UTC)SFS-7000P#Related Commands
show config
To display the startup configuration, enter the show config command in User Exec mode or Privileged Exec mode.
show config
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Unrestricted read-write user.
The show config command displays the current configuration as a series of commands in the format that you use when you execute commands in a CLI session. This command queries all active service components to collect their current configuration data and translates the data into a CLI command format.
This record of the configuration may be saved, edited, and reused to replicate a configuration.
Note
ITLs (see the <Link><bold>fc srp itl<Link> command on page 9<Link>) with default attributes (see the <Link><bold>fc srp-global itl<Link> command on page 19<Link>) do not appear in the show config command output.
Examples
The following example displays the running configuration on the Server Switch:
SFS-7000P# show configenableconfig terminalcard 2type en4port1Gno shutdownib sm subnet-prefix fe:80:00:00:00:00:00:00 priority 0interface gateway 2ip address 192.168.2.1 255.255.255.0interface ethernet 2/1ip address 192.168.1.1 255.255.255.0interface ethernet 2/2ip address 192.168.3.1 255.255.255.0arp ib 192.168.2.2 gid fe:80:00:00:00:00:00:00:00:02:c9:00:00:13:68:c3 qpn 2 2/0arp ib 192.168.2.3 gid fe:80:00:00:00:00:00:00:00:02:c9:00:00:16:af:d3 qpn 2 2/0SFS-7000P#Related Commands
show diagnostic
To display diagnostics, enter the show diagnostic command in User Exec mode or Privileged Exec mode.
show diagnostic
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
General read-only user.
Examples
The following example displays the system diagnostics available.
SFS-270# diagnostic ?SFS-7000P# show diag ?card - Show card specific diagnostic testchassis - Show chassis specific diagnostic testfan - Show fan specific diagnostic testfru-error - Show the last hardware error (if any) detectedinterface - Show interface specific diagnostic testpost - Show POST status of all FRUs in the systempower-supply - Show power supply specific diagnostic testrack-locator - Show rack locator specific diagnostic testRelated Commands
show diagnostic card
show diagnostic chassis
show diagnostic fan
show diagnostic fru-error
show diagnostic interface ethernet
show diagnostic interface fc
show diagnostic interface ib
show diagnostic post
show diagnostic power-supply
show diagnostic rack-locatorshow diagnostic card
To display completed or ongoing diagnostic tests for cards, enter the show diagnostic card command in User Exec mode or Privileged Exec mode.
show diagnostic card {all | card-selection}
Syntax Description
all
Specifies all cards on the Server Switch.
card-selection
Card or cards whose tests you want to view.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Unrestricted read-write user.
Table 6-10 lists and describes the fields in the show diagnostic card command.
Examples
The following example displays the completed and ongoing diagnostic tests on card 3.
SFS-7000P# show diag card 3================================================================================Diagnostic Tests For Cards================================================================================test : ledslot-id : 3iterations : 1action : stopresult : successpercentage-completed : 100result-string : Card LED Test, Final report : PASSEDThe following example displays the available test parameters:
SFS-7000P(config)# diagnostic card 16SFS-7000P(config-diag-card-16)# ?diagnostic Configuration Commands:exit - Exit current modehelp - Show command helphistory - Show command historystart - Initiate a teststop - Stop a testtest - Configure test typeSFS-7000P(config-diag-card-16)# test ?> led - Test type is LED test> self-test - Test type is self-testRelated Commands
show diagnostic chassis
To display completed or ongoing diagnostic tests the chassis, enter the show diagnostic chassis command in User Exec mode or Privileged Exec mode.
show diagnostic chassis
Syntax Description
This command has no arguments or keywords.
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Privilege Level:
Unrestricted read-write user.
Examples
The following example displays the completed and ongoing diagnostic tests on card 3.
SFS-120# show diagnostic chassis================================================================================Diagnostic Tests For Chassis================================================================================module-type : chassismodule-number : 1test : self-testiterations : 1option : stopOnErroraction : startresult : successpercentage-completed : 100result-string : Self Test, Final report : PASSED; Please reboot systemSFS-120#Related Commands
show diagnostic fan
To display completed or ongoing diagnostic tests for fans, enter the show diagnostic fan command in User Exec mode or Privileged Exec mode.
show diagnostic fan {all | fan-selection}
Syntax Description
all
Specifies all fans on the Server Switch.
fan-selection
Fan or fans whose tests you want to view.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
Unrestricted read-write user.
Table 6-11 lists and describes the fields in the show diagnostic fan command.
Examples
The following example displays diagnostic test results for a fan.
SFS-120# show diag fan================================================================================Diagnostic Tests For Fan================================================================================module-type : fanmodule-number : 3test : self-testiterations : 1action : stopresult : successpercentage-completed : 100result-string : Fan Self Test Completed, Final report : Passed=1, Failed=0, Total=1Related Commands
show diagnostic fru-error
To display field-replaceable unit (FRU) run-time errors, enter the show diagnostic fru-error command in User Exec mode or Privileged Exec mode.
show diagnostic fru-error
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes:
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
Unrestricted read-write user.
Table 6-12 lists and describes the fields in the show diagnostic fru-error command.
Table 6-12 show diagnostic card Command Field Descriptions
Field Descriptionfru-slot
FRU type (such as fan or power supply) and slot.
fru-error
FRU error, if any.
Examples
The following example displays FRU errors on a Cisco SFS 7000.
SFS-270# show diagnostic fru-error================================================================================Fru-Error================================================================================fru-slot fru-error--------------------------------------------------------------------------------card(1) nonecard(2) nonecard(9) nonecard(11) _FRU_ETHERNET_ERRcard(12) _FRU_ETHERNET_ERRcard(15) nonecard(16) nonefan(1) nonefan(2) nonefan(3) nonefan(4) nonepower-supply(1) nonepower-supply(2) noneRelated Commands
show diagnostic interface ethernet
To display completed or ongoing diagnostic tests for Ethernet gateway ports, enter the show diagnostic interface ethernet command in User Exec mode or Privileged Exec mode.
show diagnostic interface ethernet {port | all}
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Ethernet read-only user.
Table 6-13 lists and describes the fields in the show diagnostic interface ethernet command.
Examples
The following example displays the completed and ongoing diagnostic tests on port 1 of Ethernet gateway 9.
SFS-7000P# show diagnostic interface ethernet 9/1================================================================================Diagnostic Tests For Ethernet Interfaces================================================================================test : ledport : 9/1validation : enableddata-size : 0data-pattern : 00:00:00:00iterations : 0action : stopresult : nonepercentage-completed : 0result-string : Unknown Test Unknown status, Current report : Passed=0, Failed=0, Total=0The following example displays the diagnostic tests available:
SFS-7000P# (config)# diagnostic interface ethernet 2/1SFS-7000P# (config-diag-if-ether-2/1)# ?>diagnostic Configuration Commands:data-pattern - Configure a data pattern to use in traffic testcasesdata-size - Configure size (in octects) of payload dataexit - Exit current modehelp - Show command helphistory - Show command historyiterations - Configure number of iterations the test caseshould be runno - Disable a configuration or set defaultstart - Initiate a teststop - Stop a testtest - Configure the test case to runvalidate - Enable data validation to be performed onreceived packetsSFS-7000P# (config-diag-if-ether-2/1)# test ?ext-loopback - Configure External-Loopback testled - Configure LED testRelated Commands
show diagnostic interface fc
To display completed or ongoing diagnostic tests for Fibre Channel gateway ports, enter the show diagnostic interface fc command in User Exec mode or Privileged Exec mode.
show diagnostic interface fc {port | all}
Syntax Description
Defaults
This command has no default settings.
Command Modes:
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Table 6-14 lists and describes the fields in the show diagnostic interface fc command.
Examples
The following example displays the completed and ongoing diagnostic tests on all Ethernet ports.
SFS-7000P# show diagnostic interface ethernet all================================================================================Diagnostic Tests For Ethernet Interfaces================================================================================test : external-loopbackport : 6/3validation : enableddata-size : 0data-pattern : 00:00:00:00iterations : 0action : stopresult : nonepercentage-completed : 0result-string : External Loopback Test In-progress, Current report : Passed=0, Failed=0, Total=0The following example displays the diagnostic tests available:
SFS-7000P(config)# diagnostic interface fc 6/1SFS-7000P(config-diag-if-fc-6/1)# ?> diagnostic Configuration Commands:> data-pattern - Configure a data pattern to use in traffic test> cases> data-size - Configure size (in octects) of payload data> exit - Exit current mode> help - Show command help> history - Show command history> iterations - Configure number of iterations the test case> should be run> no - Disable a configuration or set default> source-id - Specify source identifier for use with FC Echo test> start - Initiate a test> stop - Stop a test> target-id - Specify target identifier for use with FC Echo test> test - Configure the test case to run> validate - Enable data validation to be performed on> received packets> Topspin-360(config-diag-if-fc-6/1)# test ?> echo - Configure Echo test> ext-loopback - Configure External-Loopback test> int-loopback - Configure Internal-Loopback testRelated Commands
show diagnostic interface ib
To display completed or ongoing diagnostic tests for InfiniBand switch ports, enter the show diagnostic interface ib command in User Exec mode or Privileged Exec mode.
show diagnostic interface ib {port | all}
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Table 6-15 lists and describes the fields in the show diagnostic interface ib command.
Examples
The following example displays the completed and ongoing diagnostic tests on port 1 of InfiniBand switch card 16.
SFS-7000P> show diagnostic interface ib 16/1================================================================================Diagnostic Tests For IB Interfaces================================================================================test : external-loopbackport : 16/1validation : enableddata-size : 0data-pattern : 00:00:00:00iterations : 0source-id : 00:00:00target-id : 00:00:00action : stopresult : nonepercentage-completed : 0result-string : External Loopback Test Unknown status, Current report : Passed=0, Failed=0, Total=0The following example displays the available diagnostics tests:
SFS-7000P(config)# diagnostic interface ib 16/1> SFS-7000P(config-diag-if-ib-16/1)# ?> diagnostic Configuration Commands:> data-pattern - Configure a data pattern to use in traffic test> cases> exit - Exit current mode> help - Show command help> history - Show command history> iterations - Configure number of iterations the test case> should be run> no - Disable a configuration or set default> start - Initiate a test> stop - Stop a test> test - Configure the test case to run> validate - Enable data validation to be performed on> received packets> SFS-7000P(config-diag-if-ib-16/1)# test ?> ext-cable - Configure External-Cable test> ext-loopback - Configure External-Loopback test> int-loopback - Configure Internal-Loopback testRelated Commands
show diagnostic post
To display POST error messages, enter the show diagnostic post command in User Exec mode or Privileged Exec mode.
show diagnostic post
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
Unrestricted read-write user.
Table 6-16 lists and describes the fields in the show diagnostic post command.
Examples
The following example displays POST error messages on a Cisco SFS 7000.
SFS-270# show diagnostic post================================================================================Post Status================================================================================fru-slot post-status post-error--------------------------------------------------------------------------------card(1) passed nonecard(2) passed nonecard(9) passed nonecard(11) failed _FRU_ETHERNET_ERRcard(12) failed _FRU_ETHERNET_ERRcard(15) passed nonecard(16) passed nonefan(1) passed nonefan(2) passed nonefan(3) passed nonefan(4) passed nonepower-supply(1) passed nonepower-supply(2) passed noneRelated Commands
show diagnostic power-supply
To display completed or ongoing diagnostic tests for power supplies, enter the show diagnostic power-supply command in User Exec mode or Privileged Exec mode.
show diagnostic power-supply {all | power-supply-selection}
Syntax Description
all
Specifies all fans on the Server Switch.
power-supply-selection
Power supply or supplies whose tests you want to view.
Defaults
This command has no default settings.
Command Modes:
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
Unrestricted read-write user.
Table 6-11 lists and describes the fields in the show diagnostic power-supply command.
Examples
The following example displays the completed and ongoing diagnostic tests on all power supplies.
SFS-270> show diagnostic power-supply all================================================================================Diagnostic Tests For Power Supplies================================================================================module-number : 1test : noneiterations : 1action : stopresult : nonepercentage-completed : 0result-string :show diagnostic rack-locator
To display the results of the rack locator test, enter the show diagnostic rack-locator command in User Exec mode or Privileged Exec mode.
show diagnostic rack-locator
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
Unrestricted read-write user.
Table 6-18 lists and describes the fields in the show diagnostic rack-locator command.
Examples
The following example displays rack locator test results.
SFS-7000P# show diagnostic rack-locator================================================================================Diagnostic Tests For Rack Locator================================================================================module-type : rack-locatormodule-number : 1test : lediterations : 1action : stopresult : successpercentage-completed : 100result-string : LED Test, Final report : PASSEDRelated Commands
show fan
To display the status of the fans in your Server Switch, enter the show fan command in User Exec mode or Privileged Exec mode.
show fan
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012
Privilege Level:
General read-only user.
For the health of your Server Switch, you want both fans to function while your Server Switch runs. If the operational status of a fan appears as down, contact customer support for a fan module replacement.
Table 6-19 describes the fields in the show fan command output.
Examples
The following example displays the fan settings on the Server Switch.
SFS-7000P# show fan===============================================================================Fan Information===============================================================================fan oper-status speed(%)-------------------------------------------------------------------------------1 up 932 up 913 up 894 up 85===============================================================================Fan Seeprom===============================================================================product pca pca frufan serial-number serial-number number number-------------------------------------------------------------------------------1 PY-0323-000055 PY-0323-000055 95-00011-01 98-00004-012 PY-0323-000055 PY-0323-000055 95-00011-01 98-00004-013 PY-0323-000059 PY-0323-000059 95-00011-01 98-00004-014 PY-0323-000059 PY-0323-000059 95-00011-01 98-00004-01Related Commands
show fc srp initiator
To display the attributes of initiators that you have configured on your Server Switch, enter the show fc srp initiator command in User Exec mode or Privileged Exec mode.
show fc srp initiator [guid extension]
Syntax Description
Defaults
Enter the show fc srp initiator command with no arguments to display all initiators.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
This command displays active and inactive initiators.
Enter this command without any arguments to display the initiator information for all configured SRP initiators. If you specify a GUID, you must also specify the extension.
Note
Initiators do not need to connect to the Server Switch to appear in the show output. As long as you configured them, they appear in the command output.
Examples
The following example displays the initiators that users have configured on the Server Switch.
SFS-7000P# show fc srp initiator================================================================================SRP Initiators================================================================================guid: 00:05:ad:00:00:01:29:c5extension: 00:00:00:00:00:00:00:00description: Benderwwnn: 20:01:00:05:ad:00:40:00credit: 0active-ports: 6/1pkeys:action: noneresult: nonewwpns: port wwpn fc-addr2/1 20:01:00:05:ad:20:40:00 00:00:002/2 20:01:00:05:ad:24:40:00 00:00:003/1 20:01:00:05:ad:30:40:00 00:00:003/2 20:01:00:05:ad:34:40:00 00:00:004/1 20:01:00:05:ad:40:40:00 00:00:004/2 20:01:00:05:ad:44:40:00 00:00:005/1 20:01:00:05:ad:50:40:00 00:00:005/2 20:01:00:05:ad:54:40:00 00:00:006/1 20:01:00:05:ad:60:40:00 00:00:026/2 20:01:00:05:ad:64:40:00 00:00:007/1 20:01:00:05:ad:70:40:00 00:00:007/2 20:01:00:05:ad:74:40:00 00:00:008/1 20:01:00:05:ad:80:40:00 00:00:008/2 20:01:00:05:ad:84:40:00 00:00:009/1 20:01:00:05:ad:90:40:00 00:00:009/2 20:01:00:05:ad:94:40:00 00:00:0010/1 20:01:00:05:ad:a0:40:00 00:00:0010/2 20:01:00:05:ad:a4:40:00 00:00:0011/1 20:01:00:05:ad:b0:40:00 00:00:0011/2 20:01:00:05:ad:b4:40:00 00:00:0012/1 20:01:00:05:ad:c0:40:00 00:00:0012/2 20:01:00:05:ad:c4:40:00 00:00:0013/1 20:01:00:05:ad:d0:40:00 00:00:0013/2 20:01:00:05:ad:d4:40:00 00:00:0014/1 20:01:00:05:ad:e0:40:00 00:00:0014/2 20:01:00:05:ad:e4:40:00 00:00:00Total: 1 initiators.Related Commands
fc srp initiator auto-bind
fc srp initiator-wwpn
fc srp it
fc srp itl
fc srp lu
fc srp target
fc srp-global gateway-portmask-policy restricted
fc srp-global lun-policy restricted
speedshow fc srp initiator-wwpn-view
To display SRP targets that an initiator can access through one of its virtual ports, enter the show fc srp initiator-wwpn-view command in User Exec mode or Privileged Exec mode.
show fc srp initiator-wwpn-view wwpn target
Syntax Description
wwpn
World-wide port name (WWPN) of the virtual port of the initiator.
target
Displays the targets that your initiator can access through the virtual port.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Use this command to verify that your initiator connects to all of the targets that you configured for it.
Table 6-21 lists and describes the fields in the show fc srp initiator-wwpn-view command output.
Examples
The following example displays the targets that the initiator can access through the specified virtual port.
SFS-7000P> show fc srp initiator-wwpn-view 20:03:00:05:ad:21:5a:5c target================================================================================SRP Targets Accessible to Initiator Via Port WWN 20:03:00:05:ad:51:5a:5c================================================================================wwpn: 20:01:00:60:45:17:36:1cwwnn: 20:09:00:60:45:17:36:1cdescription: SRP.T10:200100604517361Cioc-guid: 00:05:ad:00:00:01:38:80service-name: SRP.T10:200100604517361Cprotocol-ids: 04:00:00:00:00:00:00:00:00:00fc-address: 61:1b:13mtu: 0connection-type: nl-portphysical-access: 5/1-5/2,7/1Related Commands
fc srp initiator
fc srp-global lun-policy restricted
show fc srp initiatorshow fc srp it
To display initiator-target pairs that you have configured or that your Server Switch has discovered, enter the show fc srp it command in User Exec mode or Privileged Exec mode.
show fc srp it [guid extension target-wwpn]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Unrestricted read-write user.
Use this command to verify you successfully created IT pairs on your Server Switch.
Examples
The following example displays the details of an IT pair.
SFS-7000P# show fc srp it================================================================================SRP IT================================================================================guid: 00:02:c9:02:00:40:0e:d4extension: 00:00:00:00:00:00:00:00target-wwpn: 21:00:00:04:cf:86:a0:1fdescription: itnon-restricted-ports: 2/1-2/4,3/1-3/4,4/1-4/4,5/1-5/4,: 6/1-6/4,7/1-7/4,8/1-8/4,9/1-9/4,: 10/1-10/4,11/1-11/4,12/1-12/4,13/1-13/4active-ports: 5/1-5/2physical-access: 5/1-5/2,7/2mode: normal-modeaction: noneresult: noneRelated Commands
fc srp-global gateway-portmask-policy restricted
fc srp it
show interface fcshow fc srp itl
To display all ITLs that run through your Server Switch, enter the show fc srp itl command in User Exec mode or Privileged Exec mode.
show fc srp itl [guid extension wwpn LUN]
Syntax Description
Defaults
Enter the show fc srp itl command with not arguments to display all ITLs on your Server Switch.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Unrestricted read-write user.
Enter this command without arguments to display the ITL information for all connected Fibre Channel devices. This command displays active and inactive ITLs.
Table 6-23 describes the fields in the show fc srp itl command output.
Examples
The following example displays the ITLs in the configuration file on the Server Switch.
SFS-7000P# show fc srp itl================================================================================SRP ITL================================================================================guid: 00:05:ad:00:00:01:29:c5extension: 00:00:00:00:00:00:00:00target-wwpn: 21:00:00:04:cf:f6:c2:abfc-lunid: 00:00:00:00:00:00:00:00srp-lunid: 00:00:00:00:00:00:00:00logical-id (raw 64 bytes): 01:03:00:08:20:00:00:04:cf:f6:c2:ab:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00logical-id (formatted display): 2000000000000000description: itldevice-category: randomlun-policy: non restrictednon-restricted-ports: noneactive-ports: 6/1physical-access: 6/1hi-mark: 16max-retry: 5min-io-timeout: 10dynamic-path-affinity: falsedynamic-gateway-port-loadbalancing: truedynamic-storage-port-loadbalancing:dynamic-gateway-port-failover: falsedynamic-storage-port-failover:active-slots: 6Total: 1 itls.Related Commands
fc srp itl
fc srp lu
show fc srp it
show interface fcshow fc srp itl-statistics
To display ITL I/O statistics, enter the show fc srp itl-statistics command in User Exec mode or Privileged Exec mode.
show fc srp itl-statistics [guid extension wwpn LUN]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Enter this command without any arguments to display the SRP/Fibre Channel statistics for every ITL.
Table 6-24 lists and describes the output of the show fc srp itl-statistics command.
Examples
The following example displays ITL traffic statistics for the ITLs in the configuration file on the Server Switch.
SFS-7000P# show fc srp itl-statistics===========================================================================SRP ITL statistics===========================================================================guid: 00:02:c9:00:01:1d:aa:00extension: 00:00:00:00:00:00:00:00target-wwpn: 20:01:00:60:45:17:36:1csrp-lunid: 00:00:00:00:00:00:00:00slot-id: 5srp-cmds-outstanding: 0srp-errors: 0srp-initiated-ios: 0srp-bytes-read: 0srp-bytes-written: 0fcp-cmds-outstanding: 0fcp-cmds-completed: 0fcp-errors: 0fcp-initiated-ios: 0fcp-bytes-read: 0fcp-bytes-written: 0Related Commands
fc srp itl
show fc srp statisticsshow fc srp lu
To display attributes of logical units, enter the show fc srp lu command in User Exec mode or Privileged Exec mode.
show fc srp lu [logical-id]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Table 6-25 describes the fields in the show fc srp lu command output.
Examples
The following example displays the LUs (storage disks) that connect to the Server Switch.
SFS-7000P# show fc srp lu================================================================================SRP LUs================================================================================logical-id (raw 64 bytes): 01:03:00:08:20:00:00:04:cf:f6:c2:ab:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00logical-id (formatted display): 2000000000000000description: lu-SEAGATE -ST336753FC -0005device-category: randomtargets: 21:00:00:04:cf:f6:c2:abhi-mark: 16max-retry: 5min-io-timeout: 10dynamic-path-affinity: falsedynamic-gateway-port-loadbalancing: truedynamic-gateway-port-failover: falsevendor-id: SEAGATEproduct-id: ST336753FCproduct-revision: 0005physical-access: 6/1Total: 1 lus.The following example displays details about one LU.
SFS-7000P# show fc srp lu 0103000820000004cf86a01f000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000================================================================================SRP LUs================================================================================logical-id (raw 64 bytes): 01:03:00:08:20:00:00:04:cf:86:a0:1f:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00logical-id (formatted display): 2000000000000000description: lu-SEAGATE -ST336753FC -0005device-category: randomtargets: 21:00:00:04:cf:86:a0:1fhi-mark: 16max-retry: 5min-io-timeout: 10dynamic-path-affinity: falsedynamic-gateway-port-loadbalancing: truedynamic-gateway-port-failover: falsevendor-id: SEAGATEproduct-id: ST336753FCproduct-revision: 0005physical-access: 5/1-5/2,7/2SFS-7000P#Related Commands
fc srp lu
show fc srp initiator
show fc srp itl
show interface fcshow fc srp statistics
To display aggregate SRP I/O statistics for all ITLs on your Server Switch, enter the show fc srp statistics command in User Exec mode or Privileged Exec mode.
show fc srp statistics
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes:
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Use the show fc srp statistics command to determine load and error count.
The statistical information consists of the following:
•
SRP and Fibre Channel commands initiated, outstanding, and completed.
•
SRP and Fibre Channel bytes read and written.
•
SRP and Fibre Channel errors reported.
Table 6-26 describes the fields in the show fc srp statistics command output.
Examples
The following example displays traffic statistics for all of the ITLs on your Server Switch.
SFS-7000P# show fc srp statistics================================================================================SRP Global Statistics================================================================================link-events: 1410805srp-cmds-outstanding: 0srp-cmds-completed: 4srp-errors: 0srp-initiated-ios: 4srp-bytes-read: 288srp-bytes-written: 0srp-connections: 2fcp-cmds-outstanding: 0fcp-cmds-completed: 2fcp-errors: 0fcp-initiated-ios: 2fcp-bytes-read: 0fcp-bytes-written: 0Related Commands
show fc srp initiator
show fc srp itl
show interface fcshow fc srp target
To display the properties of targets (that you manually configured or your Server Switch discovered), enter the show fc srp target command in User Exec mode or Privileged Exec mode.
show fc srp target [wwpn]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Enter this command without any arguments to display all the target devices known to the Server Switch.
Table 6-27 describes the fields in the show fc srp target command output.
Examples
The following example displays the targets that connect to the Server Switch.
SFS-7000P# show fc srp target============================================================================SRP Targets============================================================================wwpn: 20:01:00:60:45:17:36:1cwwnn: 20:09:00:60:45:17:36:1cdescription: SRP.T10:200100604517361Cioc-guid: 00:05:ad:00:00:01:38:80service-name: SRP.T10:200100604517361Cprotocol-ids: 04:00:00:00:00:00:00:00:00:00fc-address: 61:1b:13mtu: 0connection-type: nl-portphysical-access: 5/1-5/2Related Commands
fc srp target
show fc srp initiatorshow fc srp-global
To display the permissions that automatically apply to all new ITs and ITLs, enter the show fc srp-global command in User Exec mode or Privileged Exec mode.
show fc srp-global
Syntax Description
This command has no arguments or keywords.
Defaults
See the fc srp-global itl command for defaults.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
Fibre Channel read-only user.
Examples:
The following example displays the default attributes of new ITLs:
SFS-7000P# show fc srp-global================================================================================SRP Global Information================================================================================default-gateway-portmask-policy : restricteddefault-lun-policy : restricteddefault-itl-hi-mark : 16default-itl-max-retry : 5default-itl-min-io-timeout : 10default-itl-dynamic-path-affinity : falsedefault-itl-dynamic-gateway-port-load-balancing : truedefault-itl-dynamic-gateway-port-failover : falsedefault-seq-itl-hi-mark : 1default-seq-itl-max-retry : 1default-seq-itl-min-io-timeout : 60default-seq-itl-dynamic-path-affinity : falsedefault-seq-itl-dynamic-gateway-port-load-balancing : falsedefault-seq-itl-dynamic-gateway-port-failover : trueRelated Commands
fc srp-global gateway-portmask-policy restricted
fc srp-global itl
fc srp-global lun-policy restrictedshow host
To display the DNS name servers and domain name that your Server Switch uses, enter the show host command in User Exec mode or Privileged Exec mode.
show host
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
Fibre Channel read-only user.
Use this command to display the network domain of the chassis and the DNS servers that your Server Switch uses to resolve network names to IP addresses.
Table 6-28 lists and describes the fields in the show host command output.
Examples
The following example displays the IP addresses of the DNS servers that the Server Switch uses to resolve host names.
SFS-7000P# show host============================================================================ Host Information============================================================================name-server-one : 10.3.106.20name-server-two : 0.0.0.0domain-name : shastaSFS-7000P#Related Commands
show ib dm ioc
To display the Device Manager input/output controller (IOC) configuration, enter the show ib dm ioc command in User Exec mode or Privileged Exec mode.
show ib dm ioc [ioc-guid | all] [services]
Syntax Description
ioc-guid
(Optional) GUID of the controller that you want to view.
all
(Optional) Displays all controllers on the IB fabric.
services
(Optional) Displays the services that run on the IOC(s).
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 3012
Privilege Level:
General read-only user.
Table 6-29 describes the fields in the show ib dm ioc command output.
Table 6-30 describes the fields in the services keyword output.
Examples
The following example displays the configuration of all IOCs on the fabric.
SFS-7000P> show ib dm ioc================================================================================IB Device Manager I/O Controller================================================================================guid: 00:05:ad:00:00:00:14:fedescription:vendor-id: 0x5adioc-device-id: 0x5addevice-version: 1subsystem-vendor-id: 0x5adsubsystem-id: 0x5adio-class: 256io-subclass: 24734protocol: 264protocol-version: 1send-msg-q-depth: 65535rdma-read-q-depth: 65535send-msg-size: -1rdma-transfer-size: -1controller-op-cap: 255service-entries: 14The following example displays all of the services on all of the IOCs in the fabric (output abridged).
SFS-7000P> show ib dm ioc services================================================================================IB Device Manager Services================================================================================ioc-guid: 00:05:ad:00:00:00:14:feservice-name: SRP.T10:2200000C5002CA21service-id: 00:00:00:00:00:00:00:66ioc-guid: 00:05:ad:00:00:00:14:feservice-name: SRP.T10:2200000C50056281service-id: 00:00:00:00:00:00:00:66Related Commands
show ib dm iou
To display the Device Manager input/output unit (IOU) configuration, enter the show ib dm iou command in User Exec mode or Privileged Exec mode.
show ib dm iou
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012
Privilege Level:
General read-only user.
Table 6-31 describes the fields in the show ib dm command output.
Examples
The following example displays the DM I/O details for the Server Switch.
SFS-7000P> show ib dm iou================================================================================IB Device Manager I/O Unit================================================================================change-id: 2352max-controllers: 1diag-device-id: 0option-rom: absentcontrollers: slot-1 IOC presentRelated Commands
show ib pm config
To view the performance monitoring configuration on an IB subnet, enter the show ib pm config command in User Execute mode or Privileged Execute mode.
show ib pm config subnet-prefix prefix
Syntax Description
subnet-prefix
Specifies the subnet prefix of the IB subnet for which you want to view performance monitoring.
prefix
Subnet prefix of the IB subnet for which you want to view performance monitoring
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
General read-only user.
Table 6-32 lists and describes the fields in the show ib pm config command output.
Examples
The following example displays the output of the show ib pm config command.
SFS-120# show ib pm config subnet-prefix fe:80:00:00:00:00:00:00================================================================================IB PM Configuration================================================================================subnet-prefix : fe:80:00:00:00:00:00:00state : enablepolling-period : 10start-delay : 60Related Commands
show ib pm connection counter
To view the performance monitoring counters on a connection, enter the show ib pm connection counter command in User Execute mode or Privileged Execute mode.
show ib pm connection counter subnet-prefix prefix src-lid source dst-lid destination
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
General read-only user.
Examples
The following example displays performance monitoring counters on a connection.
SFS-120# show ib pm connection counter subnet-prefix fe:80:00:00:00:00:00:00 src-lid 2 dst-lid 2================================================================================IB PM Port Counter Table================================================================================subnet-prefix : fe:80:00:00:00:00:00:00node-guid : 00:05:ad:00:00:01:73:bfport-num : 1chassis-guid : 00:05:ad:00:00:01:73:bfslot-num : 1ext-port-num : 1data-is-valid : falsesymbol-errors : 0link-recovery-errors : 0link-downs : 0rcv-errors : 0rcv-remote-phy-errors : 0rcv-switch-relay-errors : 0xmit-discards : 0xmit-constraint-errors : 0rcv-constraint-errors : 0local-link-integrity-errors : 0excessive-buf-overrun-errors : 0vl15-droppeds : 0xmit-data : 0rcv-data : 0xmit-pkts : 0rcv-pkts : 0Related Commands
show ib pm connection monitor
To view the performance monitoring connection monitor, enter the show ib pm connection monitor command in User Execute mode or Privileged Execute mode.
show ib pm connection monitor subnet-prefix prefix src-lid source dst-lid destination
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
General read-only user.
Examples
The following example displays the connection monitor table of a connection.
SFS-120# show ib pm connection monitor subnet-prefix fe:80:00:00:00:00:00:00 src-lid 2 dst-lid 2================================================================================IB PM Connection Monitor Table================================================================================subnet-prefix : fe:80:00:00:00:00:00:00src-lid : 2dst-lid : 2error-status : unknownutil-status : unknownRelated Commands
show ib pm port counter
To show the performance monitoring port counter configuration, enter the show ib pm port counter command in User Execute mode or Privileged Execute mode.
show ib pm port counter [config] subnet-prefix prefix
Syntax Description
config
(Optional) Displays the port counter configuration.
subnet-prefix
Specifies the subnet prefix of the counters to view.
prefix
Subnet prefix of the counters to view.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
General read-only user.
Examples
The following example shows the configuration of the performance monitoring port counter.
SFS-120# show ib pm port counter config subnet-prefix fe:80:00:00:00:00:00:00================================================================================IB PM Port Counter Configuration================================================================================subnet-prefix : fe:80:00:00:00:00:00:00state : enabledshow ib pm port monitor
To show the performance monitoring port monitor configuration, enter the show ib pm port monitor command in User Execute mode or Privileged Execute mode.
show ib pm port monitor [config | error-counter] subnet-prefix prefix [node-guid guid]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
General read-only user.
Examples
The following example displays the port monitor configuration.
SFS-120# show ib pm port monitor subnet-prefix fe:80:00:00:00:00:00:00================================================================================IB PM Port Monitor Configured Ports Table================================================================================subnet-prefix : fe:80:00:00:00:00:00:00node-guid : 00:05:ad:00:00:01:73:bfport-num : 2subnet-prefix : fe:80:00:00:00:00:00:00node-guid : 00:05:ad:00:00:01:73:bfport-num : 3Related Commands
show ib pm threshold
To view performance monitoring thresholds, enter the show ib pm threshold command in User Execute mode or Privileged Execute mode.
show ib pm threshold subnet-prefix prefix
Syntax Description
subnet-prefix
Specifies the subnet prefix of the thresholds to view.
prefix
Subnet prefix of the thresholds to view.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 7000, Cisco SFS 7008
Privilege Level:
General read-only user.
Examples
The following example displays performance monitoring thresholds.
SFS-120# show ib pm threshold subnet-prefix fe:80:00:00:00:00:00:00================================================================================IB PM Thresholds================================================================================subnet-prefix : fe:80:00:00:00:00:00:00symbol-errors : nonelink-recovery-errors : nonelink-downs : 1rcv-errors : nonercv-remote-phy-errors : nonercv-switch-relay-errors : nonexmit-discards : nonexmit-constraint-errors : nonercv-constraint-errors : nonelocal-link-integrity-errors : noneexcessive-buf-overrun-errors : nonevl15-droppeds : nonexmit-rate : 1rcv-rate : 1Related Commands
show ib sm configuration
To display information about the subnet managers on your InfiniBand fabric, enter the show ib sm configuration command in User Exec mode or Privileged Exec mode.
show ib sm configuration {subnet-prefix prefix | all} [summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Table 6-33 describes the fields in the show ib sm configuration command output.
Examples
The following example shows the detailed configuration of a subnet manager.
SFS-7000P# show ib sm configuration subnet-prefix fe:80:00:00:00:00:00:00================================================================================Subnet Manager Information================================================================================subnet-prefix : fe:80:00:00:00:00:00:00guid : 00:05:ad:00:00:00:13:f5priority : 10sm-key : 00:00:00:00:00:00:00:00oper-status : masteract-count : 787224sweep-interval(sec) : 10response-timeout(msec) : 400master-poll-intval(sec) : 3master-poll-retries : 2max-active-sms : 0LID-mask-control : 0switch-life-time : 20switch-hoq-life-time : 20host-hoq-life-time : 20The following example shows the summary configuration of a subnet manager.
SFS-7000P# show ib sm configuration subnet-prefix fe:80:00:00:00:00:00:00 summary================================================================================Subnet Manager Configuration Summary================================================================================subnet-prefix guid priority sm-key--------------------------------------------------------------------------------fe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1e:82 10 00:00:00:00:00:00:00:00Related Commands
ib sm
ib-agent
show ib-agent switch
nameshow ib sm db-sync
To display subnet manager synchronization information, enter the show ib sm db-sync command in User Exec mode or Privileged Exec mode.
show ib sm db-sync subnet-prefix {prefix | all}
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Exec mode, Privileged Exec mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Use this command to determine
•
If the database of the master subnet manager synchronizes with one or more standby databases.
•
The frequency with which the databases synchronize.
Examples
the following example displays subnet manager synchronization information.
show ib sm db-sync subnet-prefix fe:80:00:00:00:00:00:00================================================================================Subnet Manager Database Synchronization Information================================================================================subnet-prefix : fe:80:00:00:00:00:00:00enable : falsemax-backup-sms : 1session-timeout : 10poll-interval : 3cold-sync-timeout : 10cold-sync-limit : 2cold-sync-period : 900new-session-delay : 120resync-interval : 3600state : not in-syncRelated Commands
show ib sm sm-info
To display subnet manager information maintained by the SM on this device, enter the show ib sm sm-info command in User Exec mode or Privileged Exec mode.
show ib sm sm-info subnet-prefix subnet-prefix [port-guid port-guid] [summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Exec mode, Privileged Exec mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Use this command to display the SM information data maintained by the Subnet Managers on this device.
Examples
This example displays subnet manager information.
SFS-270# show ib sm sm-info subnet-prefix fe:80:00:00:00:00:00:00 summary================================================================================Summary of Discovered Subnet Managers in Fabric================================================================================subnet-prefix port-guid priority state--------------------------------------------------------------------------------Related Commands
show ib sm multicast
To display attributes of the multicast groups on your Server Switch, enter the show ib sm multicast command in User Exec or Privileged Exec mode.
show ib sm multicast {subnet-prefix prefix [mgid multicast-group-GID] [summary] | summary}
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Troubleshoot with this command when a host does not receive a broadcast packet. Use this command to verify that the multicast group includes the host. The subnet manager dynamically configures all multicast groups.
Table 6-36 describes the fields in the show ib sm configuration command output.
Examples
The following example displays a summary of the multicast groups on the Server Switch.
SFS-7000P# show ib sm multicast summary==============================================================================Summary of Multicast-Groups on Device==============================================================================subnet-prefix : fe:80:00:00:00:00:00:00MGID : ff:12:40:1b:ff:f1:00:00:00:00:00:00:ff:ff:ff:ffmulticast-group-members :port-GID : fe:80:00:00:00:00:00:00:00:05:ad:00:00:00:12:bfmember-join-state : full-memberproxy-join-status : falseRelated Commands
show ib sm neighbor
To display the InfiniBand devices that directly connect to your Server Switch, enter the show ib sm neighbor command in User Exec mode or Privileged Exec mode.
show ib sm neighbor
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Table 6-37 describes the fields in the show ib sm neighbor command output.
Examples
The following example displays the GUIDs that connect to your Server Switch and the GUIDs within your Server Switch.
Note
Truncated output appears here.
SFS-7000P# show ib sm neighbor============================================================================Subnet Management Neighbors============================================================================subnet-prefix : fe:80:00:00:00:00:00:00local-node-guid : 00:05:ad:00:00:00:11:97local-port-id : 2local-node-type : channel-adapterremote-node-guid : 00:05:ad:00:00:00:13:daremote-port-id : 1remote-node-type : switchlink-state : activelink-width-active : width4xRelated Commands
show ib sm node
To display the configuration and attributes of subnet management nodes in a subnet, enter the show ib sm node command in User Exec mode or Privileged Exec mode.
show ib sm node subnet-prefix prefix [node-guid guid] [summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
All nodes that the subnet manager on your Server Switch actively manages qualify as subnet management nodes.
Use this command to display the configuration of all the nodes on a subnet, or to display the configuration of an individual node. The output may also be displayed in summary form. The summary comprises the subnet-manager prefix, the node GUID and type, and vendor identification.
Table 6-38 describes the fields in the show ib sm node command output.
Examples
The following example (output abridged) displays the configuration of all the nodes on all the subnets on the InfiniBand fabric.
SFS-7000P# show ib sm node subnet-prefix fe:80:00:00:00:00:00:00================================================================================Subnet Management Nodes================================================================================subnet-prefix : fe:80:00:00:00:00:00:00node-guid : 00:00:2c:90:01:1b:ba:80description : swfc5 HCA-1 (Topspin HCA)base-version : 1class-version : 1type : channel adapternum-ports : 2port-guid : 00:00:2c:90:01:1b:ba:81partition-cap : 64device-id : 0revision : 0local-portnum : 1vendor-id : 00:2c:90system-image-guid : 00:00:00:00:00:00:00:00subnet-prefix : fe:80:00:00:00:00:00:00node-guid : 00:05:ad:00:00:00:13:dadescription : Topspin Switch - U1base-version : 1class-version : 1type : switchnum-ports : 8port-guid : 00:05:ad:00:00:00:13:dapartition-cap : 32device-id : 0revision : 0local-portnum : 6vendor-id : 00:05:adsystem-image-guid : 00:00:00:00:00:00:00:00The following example displays a node configuration in summary form.
SFS-7000P# show ib sm node subnet-prefix fe:80:00:00:00:00:00:00 node-guid 00:05:ad:00:00:00:13:80 summary============================================================================Subnet Manager Node Summary============================================================================subnet-prefix node-guid node-type vendor-id----------------------------------------------------------------------------fe:80:00:00:00:00:00:00 00:05:ad:00:00:00:13:80 channel adapter 00:05:adSFS-7000P#Related Commands
show ib sm partition
To display the partitions that the subnet manager on your Server Switch manages, enter the show ib sm partition command in User Exec mode or Privileged Exec mode.
show ib sm partition
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
In the output, ff:ff refers to the default partition, which cannot be altered. Members of partitions are identified by their Node GUID and port-number, as displayed below.
A single partition can have members that have full-membership, as well as members that have limited membership.
Refer to the Element Manager User Guide for more detailed partition information.
Table 6-39 lists and describes the fields in the show ib sm partition command output.
Examples
The following example displays the configuration of all nodes on all subnets on the InfiniBand fabric.
SFS-7000P# show ib sm partition===============================================================================Partitions Managed By The Subnet Managers===============================================================================subnet-prefix : fe:80:00:00:00:00:00:00p_key : ff:ffpartition-members :node-guid : 00:05:ad:00:00:00:02:40port-number : 0member-type : full-membernode-guid : 00:05:ad:00:00:00:02:42port-number : 0member-type : full-memberRelated Commands
show ib sm port
To display all InfiniBand ports on the fabric, the nodes to which the ports belong, the capabilities of the ports, and the link statistics of the ports, enter the show ib sm port command in User Exec mode or Privileged Exec mode.
show ib sm port subnet-prefix prefix [node-guid guid] [summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Use this command to verify that all of the ports in your fabric came up when the SM initialized them.
Port information may be reported for all the ports on a specific subnet or all the ports comprising a specific node. The output may also be displayed in summary form.
Table 6-40 describes the fields in the show ib sm port command output.
Examples
The following example displays the details of the ports that the specified subnet manager manages.
SFS-7000P> show ib sm port subnet-prefix fe:80:00:00:00:00:00:00================================================================================Subnet Management Ports================================================================================subnet-prefix : fe:80:00:00:00:00:00:00node-guid : 00:02:c9:01:07:e4:41:d0if-index : 1mkey : 00:00:00:00:00:00:00:00gid-prefix : fe:80:00:00:00:00:00:00lid : 2master-sm-lid : 1cap-mask : 00:10:02:48diag-code : 10:26mkey-lease-period : 15link-width-enabled : 3link-width-supported : 3link-width-active : 2link-speed-supported : 1state : activephy-state : no state changelink-down-def-state : pollingmkey-prot-bits : 0lmc : 0link-speed-active : 1link-speed-enabled : 1neighbor-mtu : 2048master-sm-SL : 0VL-cap : vl0-vl7VL-high-limit : 0VL-arb-high-cap : 8VL-arb-low-cap : 8mtu-cap : 2048VL-stall-count : 16HOQ-life : 7oper-VL : vl0-vl7in-part-enforce : falseout-part-enforce : falsein-filter-raw-pkt-enf : falseout-filter-raw-pkt-enf : falsemkey-violation : 0pkey-violation : 0qkey-violation : 0guid-cap : 32subnet-timeout : 8resp-time : 8local-phy-error : 0local-overrun-error : 0The following example displays a summary of the ports that the specified subnet manager manages.
SFS-7000P> show ib sm port subnet-prefix fe:80:00:00:00:00:00:00 summary================================================================================Subnet Manager Port Summary================================================================================subnet-prefix node-guid if-index lid state--------------------------------------------------------------------------------fe:80:00:00:00:00:00:00 00:02:c9:01:07:e4:41:d0 1 2 activefe:80:00:00:00:00:00:00 00:02:c9:01:07:e4:41:d0 2 3 activefe:80:00:00:00:00:00:00 00:02:c9:01:07:e4:57:b0 1 6 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 0 1 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 1 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 2 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 3 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 4 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 5 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 6 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 7 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:60 8 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 0 4 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 1 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 2 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 3 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 4 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 5 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 6 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 7 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:62 8 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 0 5 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 1 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 2 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 3 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 4 0 activefe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 5 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 6 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 7 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:1c:64 8 0 downfe:80:00:00:00:00:00:00 00:05:ad:00:00:01:29:8f 1 7 activeSFS-7000P>Related Commands
ib sm
show ib sm configuration
show ib sm multicast
show ib sm neighbor
show ib sm partition
show ib sm portshow ib sm service
To display services on your subnet, enter the show ib sm service command in User Exec mode or Privileged Exec mode.
show ib sm service [subnet-prefix {prefix | all} [p_key pkey | service-gid GID | service-id ID]] [summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
User Execute mode, Privileged Execute mode.
Privilege Level:
InfiniBand read-only user.
Services represent actions or functions that a node can perform across the network at the request of another node. Nodes register their services with the subnet manager so other nodes can discover and use these services. The GID of a service matches the GID of the host that provides the service.
Switch information may be reported for all the switches on a specific subnet or for a specific switch. The output may also be displayed in summary form.
Table 6-41 lists and describes the fields in the show ib sm service command output.
Examples
The following example displays the services on the Server Switch.
SFS-120# show ib sm service subnet-prefix fe:80:00:00:00:00:00:00================================================================================Summary of Services on Device================================================================================subnet-prefix : fe:80:00:00:00:00:00:00service-id : 10:00:0c:e1:00:41:54:53GID : fe:80:00:00:00:00:00:00:00:02:c9:02:00:00:24:41p_key : ff:fflease : indefiniteservice-key : 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00service-name : DAPL Address Translation Serviceservice-data :data-8 : 00:00:00:00:00:00:00:00:00:00:00:00:c0:a8:01:02data-16 : 0000:0000:0000:0000:0000:0000:0000:0000data-32 : 00000000:00000000:00000000:00000000data-64 : 0000000000000000:0000000000000000subnet-prefix : fe:80:00:00:00:00:00:00service-id : 10:00:0c:e1:00:41:54:53GID : fe:80:00:00:00:00:00:00:00:02:c9:02:00:00:24:7dp_key : ff:fflease : indefiniteservice-key : 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00service-name : DAPL Address Translation Serviceservice-data :data-8 : 00:00:00:00:00:00:00:00:00:00:00:00:c0:a8:01:01data-16 : 0000:0000:0000:0000:0000:0000:0000:0000data-32 : 00000000:00000000:00000000:00000000data-64 : 0000000000000000:0000000000000000The following example displays a summary of the services on the Server Switch.
SFS-120# show ib sm service subnet-prefix fe:80:00:00:00:00:00:00 summary================================================================================Summary of Services on Device================================================================================subnet-prefix : fe:80:00:00:00:00:00:00service-id : 10:00:0c:e1:00:41:54:53GID : fe:80:00:00:00:00:00:00:00:02:c9:02:00:00:24:41service-data :data-8 : 00:00:00:00:00:00:00:00:00:00:00:00:c0:a8:01:02data-16 : 0000:0000:0000:0000:0000:0000:0000:0000data-32 : 00000000:00000000:00000000:00000000data-64 : 0000000000000000:0000000000000000subnet-prefix : fe:80:00:00:00:00:00:00service-id : 10:00:0c:e1:00:41:54:53GID : fe:80:00:00:00:00:00:00:00:02:c9:02:00:00:24:7dservice-data :data-8 : 00:00:00:00:00:00:00:00:00:00:00:00:c0:a8:01:01data-16 : 0000:0000:0000:0000:0000:0000:0000:0000data-32 : 00000000:00000000:00000000:00000000data-64 : 0000000000000000:0000000000000000Related Commands
ib sm
show ib sm configuration
show ib sm multicast
show ib sm neighbor
show ib sm partition
show ib sm portshow ib sm subscription
To display event subscriptons or information records managed by yourssubnet manager on this device, enter the show ib sm subscription command in User Exec mode or Privileged Exec mode.
show ib sm subscripton [subnet-prefix {subnet-prefix} [lid LID] [node-guid GUID [port-num port-num]] [summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Subscriptions represent The LID of a node matches the LID of the host that provides the service.The GID of a service matches the GID of the host that provides the service.
Switch information may be reported for all the switches on a specific subnet or for a specific switch. The output may also be displayed in summary form.
Table 6-41 lists and describes the fields in the show ib sm service command output.
Examples
The following example displays a summary of the event subscriptions managed on the Server Switch.
SFS-120#
The following example displays a summary of the event subscriptions managed on the Server Switch.
SFS-120# show ib sm subscription subnet-prefix fe:80:00:00:00:00:00:00 node-guid aa:aa:aa:aa:aa:aa:aa:aa summary================================================================================Summary of Event Subscriptions Managed================================================================================LID node-guid port-num LID-range is-generic trap-num-device-id--------------------------------------------------------------------------------Related Commands
ib sm
show ib sm configuration
show ib sm multicast
show ib sm neighbor
show ib sm partition
show ib sm portshow ib sm switch
To display the attributes of all IB switches in your fabric (for debug purposes), enter the show ib sm switch command in User Exec mode or Privileged Exec mode.
show ib sm switch {subnet-prefix prefix | all} [node-guid guid][summary]
Syntax Description
Defaults
This command has no default settings.
Command Modes
User Execute mode, Privileged Execute mode.
Usage Guidelines
Platform Availability:
Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, IB Server Switch Module
Privilege Level:
InfiniBand read-only user.
Switch information may be reported for all the switches on a specific subnet or all the switches comprising a specific node. The output may also be displayed in summary form.
Table 6-43 lists and describes the fields in the show ib sm switch command output.