Table A-1 Cisco 819 ISR Specifications
Description
|
Hardened Design Specification
(Cisco 819HG and Cisco 819HG-4G ISRs)
|
Non-Hardened Design Specifications
(Cisco 819G and Cisco 819G-4G ISRs)
|
Hardened Design Specifications
(C819HGW and C819HWD ISRs)
|
Physical Characteristics
|
|
Dimensions (H x W x D)
|
1.73 x 7.7 x 8.1 in
(44 x 196 x 206 mm)
|
1.67 x 7.7 x 7.2 in
(42 x 196 x 183 mm)
|
1.73 x 7.7 x 9.0 in
(44 x 196 x 229 mm)
|
Weight
|
3.2 lb (1.5 kg)
|
2.3 lb (1.0 kg)
|
3.4 lb (1.54 kg)
|
Maximum Power Consumption
|
11 W
|
20 W
|
Environmental Operating Ranges
|
|
Operating Temperature and Altitude
|
-13 to 140°F
(-25 to 60°C)
|
32 to 104°F
(0 to 40°C)
|
-13 to 140°F
(-25 to 60°C)
|
Derate max operating temperature 1.5°C per 1000 feet above 5000 ft
|
10,000 ft maximum
|
Humidity
|
Maximum 95% non-condensing RH
|
Maximum 85% non-condensing RH
|
Maximum 95% non-condensing RH
|
Environmental Tests
|
Ingress Protection Rating
|
IP 41 per IEC 60529 for Vertical Falling Water, Pollution Degree 3
|
IP 20 per IEC 60529
|
IP 41 per IEC 60529 for Vertical Falling Water, Pollution Degree 3
|
Humidity
|
Non-condensing Relative Humidity: 5% to 95%
|
Pollution
|
Pollution 3 for Dust
|
Military Standard
|
MIL-STD-810G Method 514.6: Procedure 1 Category 4, Secured Cargo - Common Carrier
|
MIL-STD-810G Method 514.6: Procedure 1 Category 20, Ground Vehicles
|
MIL-STD-810G Method 516.6. Procedure 1, Functional Shock
|
MIL-STD-810G Method 516.6. Procedure 5, Crash Hazard
|
MIL-STD-810G Method 516.6. Procedure 6, Bench Handling
|
Vibration and Shock (Railway Vehicles)
|
EN61373 Functional Random Vibe - Category 1, Class B
|
EN61373 Simulated Non-op Long-life Vibe - Category 1, Class B
|
EN61373 Non-op Shock, Class B
|
Heavy-Duty Vehicle Applications
|
SAE J1455 Operating Random Vibe, Cab Mounted Truck
|
SAE J1455 Operating Sinusoidal Vibe, Category 3
|
SAE J1455 Non-operating Sinusoidal Vibe, Category 3
|
SAE J1455 Handling Drop Test
|
Certifications
|
Standard Safety Certifications
|
UL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1, 2nd edition, EN 60950-1, 2nd edition; CB to IEC 60950-1, 2nd edition with all group differences and national deviations
|
UL 60950-1, 2nd edition; CAN/CSA C22.2 No. 60950-1, 2nd edition, EN 60950-1, 2nd edition; CB to IEC 60950-1, 2nd edition with all group differences and national deviations; S/NZS 60950-1, first edition (Australia/New Zealand)
|
EMC Emissions
|
EN55022/CISPR22, CFR 47 Part 15, ICES003, VCCI-V-3, AS/NZS CISPR22, CNS13438, CISPR22, CNS13438, EN300-386, EN61000-3-2, EN61000-3-3, and EN61000-6-1
|
EMC Immunity
|
EN55024/CISPR24, (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11), and EN300-386
|
Radio Immunity
|
EN301 489-1, EN 301 489-7, and EN301 489-24
|
Transportation/Storage Conditions
|
Temperature
|
-40 to158°F (-40 to 70°C)
|
-40 to185°F
(-40 to 85°C)
|
Humidity
|
5-95%
|
Altitude
|
4570 m (15,000 ft)
|
|
|
Input Voltage
|
85-264 VAC
100-240 VAC nominal
|
Maximum Power Consumption
|
25 W
|
Maximum Output Power Rating
|
20 W
(5 VDC, 4 Amps)
|
Router DC Power Adapter
|
Input Voltage
|
12 VDC nominal
PWRx-20W-12VDC (10 VDC to 36 VDC operating range)
|
24 VDC nominal
PWRx-20W-24VDC (18 VDC to 75 VDC operating range)
|
Maximum Power Consumption
|
25 W
|
Maximum Output Power Rating
|
20 W
(5 VDC, 4 Amps)
|
Altitude
|
Operating: -500 to 10,000 ft, de-rating operating temperature 1°C per 1,000 feet
|
Non-operating: -1,000 to 30,000 ft
|
Cable Length
|
Input cable: 1 m
Output cable: 1.3 m
|
Inrush Current
|
50 A @ 25°C
|
Temperature
|
Operating: -30 to 60°C, still air condition
|
Non-operating: -40 to 85°C
|
Humidity
|
Operating: 10% to 95%, non-condensing
|
Non-operating: 10% to 95%, non-condensing
|
Thermal Shock
|
Operating: -20 to 60°C at 0.5°C per minute
|
Non-operating: -40 to 85°C with change over time between 2 and 3 minutes.
|
Vibration
|
Operating: 0.41 grms from 3 to 500 Hz with spectral break points of 0.0005 g2/Hz at 10 Hz and 200 Hz and 5 dB/octave roll off at each end; 2 hours per axis.
|
Non-Operating: 1.12 grms from 3 to 500 Hz with spectral break points of 0.0065 g2/Hz at 10 Hz and 100 Hz and 5 dB/octave roll off at each end; 30 minutes per axis.
|
Shock
|
Half sine (operating): Duration = <2ms Velocity = 2.11m/s Number of shocks: a series of 6 shocks one on each side
Trapezoidal shock (non-operating): Duration = 12 to 25 ms Number of shocks: a series of 6 shocks one on each side
|
Martek Railway Power Adapters 2
|
Nominal Input Voltages
|
—
|
—
|
24 V
52 V
72 V
|
In-ceiling Plenum
|
—
|
—
|
No
|
IP 65
|
—
|
—
|
Yes
|
Extended Shock-vibe
|
—
|
—
|
Yes
EN50155 (EN61373) and RIA20
|
Maximum Power Consumption
|
—
|
—
|
25 W
|
Maximum Output Power Rating
|
—
|
—
|
20 W
|
Operating Temperature
|
—
|
—
|
-13 to 140°F
(-25 to 60°C)
|
Antenna (Diversity and Antenna 3G-ANTM1919D)
|
Antenna Dimensions
|
7.63 x 0.94 x 0.63 in (19.38 x 2.39 x 1.60 cm)
|
Frequency Range
|
806 to 960 MHz and 1710 to 2170 MHz
|
Gain
|
0 decibels relative to isotropic (dBi) (806 to 960 MHz) and 0 dBi (1710 to 2170 MHz)
|
Maximum Power
|
25 W
|
Connector
|
TNC male
|
Voltage Standing Wave Ratio
|
< 2.5:1
|
Nominal Impedance
|
50 ohms
|