- NTP-G168 Performing the Terminal or Hub Node with 40-MUX-C and 40-DMX-C Cards Acceptance Test
- NTP-G42 Performing the Terminal Node with 32WSS and 32DMX Cards Acceptance Test
- NTP-G167 Performing the Terminal Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test
- NTP-G43 Performing the ROADM Node with 32WSS and 32DMX Cards Acceptance Test
- NTP-G180 Performing the ROADM Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test
- NTP-G276 Performing the 80-Channel n-degree ROADM Node Acceptance Tests
- NTP-G44 Performing the Anti-ASE Hub Node Acceptance Test
- NTP-G45 Performing the C-Band and L-Band Line Amplifier Node with OSCM Cards Acceptance Test
- NTP-G46 Performing the C-Band Line Amplifier Node with OSC-CSM Cards Acceptance Test
- NTP-G156 Performing the L-Band Line Amplifier Node with OSC-CSM Cards Acceptance Test
- NTP-G47 Performing the C-Band Line Amplifier Node with OSCM and OSC-CSM Cards Acceptance Test
- NTP-G157 Performing the L-Band Line Amplifier Node with OSCM and OSC-CSM Cards Acceptance Test
- NTP-G49 Performing the Active OADM Node Acceptance Test on a Symmetric Node with OSC-CSM Cards
- NTP-G50 Performing the Passive OADM Node Acceptance Test on a Symmetric Node with OSC-CSM Cards
- NTP-G186 Performing the Four-Degree and Eight-Degree Mesh Patch Panel Acceptance Test
- NTP-G187 Performing the Multiring Site Acceptance Test
- NTP-G188 Performing the Native Mesh Node Acceptance Test
- NTP-G189 Performing the Node Upgrade Acceptance Test
- NTP-G243 Performing the Two-Degree ROADM Node with 40-SMR-1-C and OPT-AMP-17-C Cards Acceptance Test
- NTP-G244 Performing the Four Degree ROADM Node with 40-SMR-2-C Cards Acceptance Test
Performing Node Acceptance Tests
This chapter provides test procedures to verify that installed cards are operating correctly in a NCS 2002 and NCS 2006 node. The procedures are optional.
![]() Note | The procedures and tasks described in this chapter are applicable to the Cisco NCS 2002 and Cisco NCS 2006 platforms, unless noted otherwise. |
- NTP-G168 Performing the Terminal or Hub Node with 40-MUX-C and 40-DMX-C Cards Acceptance Test
- NTP-G42 Performing the Terminal Node with 32WSS and 32DMX Cards Acceptance Test
- NTP-G167 Performing the Terminal Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test
- NTP-G43 Performing the ROADM Node with 32WSS and 32DMX Cards Acceptance Test
- NTP-G180 Performing the ROADM Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test
- NTP-G276 Performing the 80-Channel n-degree ROADM Node Acceptance Tests
- NTP-G44 Performing the Anti-ASE Hub Node Acceptance Test
- NTP-G45 Performing the C-Band and L-Band Line Amplifier Node with OSCM Cards Acceptance Test
- NTP-G46 Performing the C-Band Line Amplifier Node with OSC-CSM Cards Acceptance Test
- NTP-G156 Performing the L-Band Line Amplifier Node with OSC-CSM Cards Acceptance Test
- NTP-G47 Performing the C-Band Line Amplifier Node with OSCM and OSC-CSM Cards Acceptance Test
- NTP-G157 Performing the L-Band Line Amplifier Node with OSCM and OSC-CSM Cards Acceptance Test
- NTP-G49 Performing the Active OADM Node Acceptance Test on a Symmetric Node with OSC-CSM Cards
- NTP-G50 Performing the Passive OADM Node Acceptance Test on a Symmetric Node with OSC-CSM Cards
- NTP-G186 Performing the Four-Degree and Eight-Degree Mesh Patch Panel Acceptance Test
- NTP-G187 Performing the Multiring Site Acceptance Test
- NTP-G188 Performing the Native Mesh Node Acceptance Test
- NTP-G189 Performing the Node Upgrade Acceptance Test
- NTP-G243 Performing the Two-Degree ROADM Node with 40-SMR-1-C and OPT-AMP-17-C Cards Acceptance Test
- NTP-G244 Performing the Four Degree ROADM Node with 40-SMR-2-C Cards Acceptance Test
NTP-G168 Performing the Terminal or Hub Node with 40-MUX-C and 40-DMX-C Cards Acceptance Test
This procedure tests a DWDM terminal or hub node with 40-MUX-C and 40-DMX-C cards installed. |
|
![]() Note |
|
Step 1 | From the View menu, choose Go to Network View. | ||
Step 2 | Click the
Alarms tab.
| ||
Step 3 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Verify that all statuses under Link Status are listed as Success - Changed or Success - Unchanged. If a different status appears, complete the NTP-G37 Running Automatic Node Setup task. | ||
Step 4 | Create a physical loopback on
the Side A (or terminal) OPT-BST or OPT-BST-E amplifier by using a patchcord
with 10-dB bulk attenuators to connect the LINE TX port to the LINE RX port.
| ||
Step 5 | Verify that the OSC link becomes active on the Side A OSCM or OSC-CSM card. (The OSC termination must already be provisioned. If not, complete the NTP-G38 Provisioning OSC Terminations task. | ||
Step 6 | Set the tunable laser or the TXP_MR_10E_C card to the first wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm). Refer to the tunable laser manufacturer’s documentation or the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. | ||
Step 7 | Connect the tunable laser transmitter or TXP_MR_10E_C card DWDM TX port to the CHAN RX 01 port on the Side A (or terminal) 40-MUX-C card using the available patch panel. | ||
Step 8 | Display the Side A (or terminal) 40-MUX-C card in card view. | ||
Step 9 | Click the tabs. | ||
Step 10 | Change the Port 1 administrative state to OOS,MT (ANSI) or Locked,maintenance (ETSI). | ||
Step 11 | Verify that the Port 1 power
level reaches the provisioned VOA Power Ref set point.
| ||
Step 12 | If an OPT-BST, OPT-BST-E, or OPT-BST-L card is installed, complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task on the Side A (or terminal) OPT-BST, OPT-BST-E, or OPT-BST-L to ensure that the amplifier is working properly. | ||
Step 13 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task on the Side A (or terminal) OPT-PRE card to ensure that the amplifier is working properly. | ||
Step 14 | Complete the “DLP-G78 Verifying the 32MUX-O or 40-MUX-C Card Power” task to verify that the 40-MUX-C card is powered correctly. | ||
Step 15 | Complete the “DLP-G269 Verifying the 32DMX-O or 40-DMX-C Card Power” task to verify that the 40-DMX-C card is powered correctly. | ||
Step 16 | Restore the default IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) administrative state to the 40-MUX-C port that was changed to OOS,MT (ANSI) or Locked,maintenance (ETSI) in step 10. | ||
Step 17 | Repeat steps 6 through 16 for the remaining 31 wavelengths of the 100-GHz grid to verify the correct behavior of all variable optical attenuators (VOAs) inside the 40-MUX-C card. | ||
Step 18 | Remove the loopback created in step 4. | ||
Step 19 | If the node is a hub node, repeat steps 4 through 18 for the Side B cards. | ||
Step 20 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 21 | Click the
Alarms tab.
|
NTP-G42 Performing the Terminal Node with 32WSS and 32DMX Cards Acceptance Test
Step 1 | Display the terminal node in node view (single-shelf mode) or multishelf view (multishelf mode). | ||
Step 2 | Click the
Alarms tab.
| ||
Step 3 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Verify that all statuses under Link Status are listed as Success - Changed or Success - Unchanged. If a different status appears, or if errors (indicated in red) appear, delete the OSC channels and complete the "NTP-G37 Run Automatic Node Setup” procedure in "Manage the Shelf" chapter. Provision the OSC channels when automatic node setup (ANS) is complete. | ||
Step 4 | Create a physical loopback on
the OPT-BST, OPT-BST-E, or OSC-CSM card by using a patchcord with 10-dB bulk
attenuators to connect the LINE TX port to the LINE RX port.
| ||
Step 5 | Wait approximately two minutes, then verify that the OSC link is active on the Side A OSCM or OSC-CSM card by observing whether or not the loss of signal (LOS) alarm on the OSCM or OSC-CSM (and the OPT-BST or OPT-BST-E card, if present) clears. (The OSC termination must already be provisioned. If not, complete the "NTP-G38 Provision OSC Terminations” procedure in "Manage the Shelf" chapter.) | ||
Step 6 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following
substeps. If you are using a TXP_MR_10E_C card, continue with
Step 7.
| ||
Step 7 | If you are using a TXP_MR_10E_C card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task on page 15-23 for the TXP containing the wavelength you will test. Refer to Table 15-1 on page 15-40, if needed. | ||
Step 8 | Using the available patch
panel, connect the tunable laser transmitter or the TXP_MR_10E_C card DWDM TX
port to the CHAN RX 01 port on the 32WSS card.
| ||
Step 9 | Display the 32WSS card in card view. | ||
Step 10 | Click the Provisioning > Optical Chn Optical Connectorn > Parameters tabs, where n = the optical connector number that carries the wavelengths you will test. Refer to Table 15-1 on page 15-40, if needed. | ||
Step 11 | Click the Admin State table cell for the add (CHAN-RX) port carrying the tested wavelength, then choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the drop-down list. For example, if the tested wavelength is 1530.33 nm (shown as 1530.3), you would click the Port 1 (CHAN-RX) Admin State field and choose OOS,MT or Locked,maintenance from the drop-down list. | ||
Step 12 | Change the administrative state of the pass-through port corresponding to the port in Step 8 to OOS,MT (ANSI) or Locked,maintenance (ETSI). For example, if the tested wavelength is 1530.33 nm (shown as 1530.3), you would click the Port 33 (PASS-THROUGH) Admin State field and choose OOS,MT or Locked,maintenance from the drop-down list. Refer to Table 15-1 on page 15-40, if needed. | ||
Step 13 | Click Apply, then click Yes. | ||
Step 14 | Click the Maintenance tab. | ||
Step 15 | For Channel #1, change the Operating Mode to Add Drop. | ||
Step 16 | Click Apply, then click Yes. | ||
Step 17 | Click the Provisioning> Optical Chn Optical Connectorn> Parameters tabs, where n = the optical connector number that carries the wavelength under test. | ||
Step 18 | Verify that the actual power coming from the tunable laser or TXP_MR_10E_C card shown under the Power column is equal to the specified VOA Power Ref power (+/– 0.2 dB) shown in the same row. | ||
Step 19 | Click the Optical Line tab. | ||
Step 20 | Verify that the Port 83 (COM-TX) Power column value is the same as the VOA Power Ref set point in Step 18 (+/– 0.5 dB). This verifies that the optical signal is traveling correctly through the 32WSS card. | ||
Step 21 | If an OPT-BST or OPT-BST-E card is installed, complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task on page 15-4 on the OPT-BST or OPT-BST-E to ensure that the amplifier is working properly. | ||
Step 22 | If an OSC-CSM is installed,
continue with
Step 24. If an OPT-BST
is installed, verify the connection between Port 67 (COM-TX) on the 32WSS and
Port 1 (COM-RX) on the OPT-BST or OPT-BST-E cards:
| ||
Step 23 | If an OPT-BST, OPT-BST-E, or OPT-BST-L card is installed on the Side A or terminal side, complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task on page 15-4 to ensure that the amplifier is working properly. | ||
Step 24 | Complete the following
steps to verify the connection between Port 67 (COM-TX) on the 32WSS and Port 2
(COM-RX) on the OSC-CSM card:
| ||
Step 25 | Complete the following
steps to verify the connection between Port 2 (COM-TX) on the OPT-PRE card and
Port 33 (COM-RX) on the 32DMX card:
| ||
Step 26 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task on page 15-5 on the OPT-PRE to ensure that the amplifier is working properly. | ||
Step 27 | Complete the “DLP-G270 Verify the 32DMX or 40-DMX-C Power” task on page 15-14 to verify that the 32DMX card is powered correctly. | ||
Step 28 | Display the 32WSS in card view. | ||
Step 29 | Click the Maintenance tab. | ||
Step 30 | For the circuit (channel) under test, click the Operating Mode table cell and choose Not Assigned from the drop-down list. | ||
Step 31 | Click Apply, then Yes. | ||
Step 32 | Click the tabs, where n = the optical connector number that carries the wavelength under test. | ||
Step 33 | Click the Admin State table cell. Choose IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) from the drop-down list for all ports that were changed to OOS,MT or Locked,maintenance. | ||
Step 34 | Click Apply, then Yes. | ||
Step 35 | Repeat Steps 6 through 34 for the remaining 31 wavelengths of the 100-Ghz grid to verify the correct behavior of all VOAs inside the 32WSS card. | ||
Step 36 | Disconnect the TXP card or tunable laser from the 32WSS card. | ||
Step 37 | Remove the loopback created in Step 4. | ||
Step 38 | Complete the "NTP-G37 Run Automatic Node Setup” procedure in "Manage the Shelf" chapter to restore the original configuration. | ||
Step 39 | Click the
Alarms tab.
|
DLP-G270 Verifying the 32DMX or 40-DMX-C Power
This task verifies that the 32DMX or 40-DMX-C card is provisioned to the correct power. |
|
NTP-G167 Performing the Terminal Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test
![]() Note |
|
Step 1 | Display the terminal node in node view (single-shelf mode) or multishelf view (multishelf mode). | ||
Step 2 | Click the
Alarms tab.
| ||
Step 3 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Verify that all statuses under Link Status are listed as Success - Changed or Success - Unchanged. If other statuses appear, or if errors (indicated in red) appear, delete the OSC channels and complete the NTP-G37 Running Automatic Node Setup task. Provision the OSC channels when ANS is complete. | ||
Step 4 | If no OSC terminations are present, complete the NTP-G38 Provisioning OSC Terminations task. | ||
Step 5 | Create a physical loopback on
the OPT-BST, OPT-BST-E, OPT-AMP-17, or OSC-CSM card by connecting a fiber optic
jumper between the LINE TX and RX ports. For OPT-BST or OPT-BST-E cards,
connect a 10 dB bulk attenuator to each end of the jumper. The OSC-CSM card
does not require attenuation.
| ||
Step 6 | Provision OSC terminations. Complete the NTP-G38 Provisioning OSC Terminations task. | ||
Step 7 | Wait approximately two minutes, then verify that the OSC link is active on the Side A OSCM or OSC-CSM card by observing whether or not the LOS alarm on the OSCM or OSC-CSM (and the OPT-BST or OPT-BST-E card, if present) clears. (The OSC termination must already be provisioned. If not, complete the NTP-G38 Provisioning OSC Terminations task. | ||
Step 8 | If you are using a tunable laser, follow the manufacturer’s instructions to complete the following substeps. If you are using a TXP_MR_10E_C card, continue with step 9. | ||
Step 9 | If you are using a TXP_MR_10E_C card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task for the TXP containing the wavelength you will test. Refer to Table 1, if needed. | ||
Step 10 | Using the available patch
panel, connect the tunable laser transmitter or the TXP_MR_10E_C card DWDM TX
port to the correct CHAN RX port on the 40-WSS-C card for the wavelength that
you want to test. Refer to Table 4-1 on page 4-28, if needed. For example, if
the tested wavelength is 1530.33 nm (shown as 1530.3), then connect the
TXP_MR_10E_C card DWDM TX port to the Optical Connector 1, CHAN RX 01 port on
the 40-WSS-C card.
| ||
Step 11 | Display the 40-WSS-C card in card view. | ||
Step 12 | Click the tabs, where n = the optical connector number that carries the wavelengths you will test. Refer to Table 1, if needed. | ||
Step 13 | Click the Admin State table cell for the add (CHAN-RX) port carrying the tested wavelength, then choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the drop-down list. For example, if the tested wavelength is 1530.33 nm (shown as 1530.3), you would click the Port 1 (CHAN-RX) Admin State field and choose OOS,MT or Locked,maintenance from the drop-down list. | ||
Step 14 | Change the administrative state of the pass-through port corresponding to the port in step 10 to OOS,MT (ANSI) or Locked,maintenance (ETSI). For example, if the tested wavelength is 1530.33 nm (shown as 1530.3), you would click the Port 41 (PASS-THROUGH) Admin State field and choose OOS,MT or Locked,maintenance from the drop-down list. Refer to Table 1, if needed. | ||
Step 15 | Click Apply, then click Yes. | ||
Step 16 | Click the Maintenance tab. | ||
Step 17 | For Channel #1, change Operating Mode to Add Drop. | ||
Step 18 | Click Apply, then click Yes. | ||
Step 19 | Click the tabs, where n = the optical connector number that carries the wavelength under test. | ||
Step 20 | Verify that the actual power coming from the tunable laser or TXP_MR_10E_C card shown under the Power column is equal to the specified VOA Power Ref power (+/– 0.2 dB) shown in the same row. | ||
Step 21 | Click the Optical Line tab. | ||
Step 22 | Verify that the Port 83 (COM-TX) Power column value is the same as the VOA Power Ref set point in Step 20 (+/– 0.5 dB). This verifies that the optical signal is traveling correctly through the 40-WSS-C card. | ||
Step 23 | If an OPT-BST, OPT-BST-E, or OPT-BST-L card is installed, complete the DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power on the OPT-BST or OPT-BST-E to ensure that the amplifier is working properly. If an OSC-CSM is installed, complete the “DLP-G84 Verifying the OSC-CSM Incoming Power” task. | ||
Step 24 | If an OSC-CSM is installed,
continue with
Step 26. If an OPT-BST
is installed, verify the connection between Port 83 (COM-TX) on the 40-WSS-C
and Port 1 (COM-RX) on the OPT-BST or OPT-BST-E cards:
| ||
Step 25 | If an OPT-BST, OPT-BST-E, or OPT-BST-L card is installed on the Side A or terminal side, complete the DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power to ensure that the amplifier is working properly. Continue with step 28. | ||
Step 26 | Complete the following
steps to verify the connection between Port 83 (COM-TX) on the 40-WSS-C and the
Port 2 (COM-RX) on the OSC-CSM card:
| ||
Step 27 | Complete the following
steps to verify the connection between Port 2 (COM-TX) on the OPT-PRE card and
Port 41 (COM-RX) on the 40-DMX-C card:
| ||
Step 28 | If an OPT-PRE card is installed on the Side A or terminal side, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task on the OPT-PRE card to ensure that the amplifier is working properly. If OSC-CSM cards are installed, complete the “DLP-G84 Verifying the OSC-CSM Incoming Power” task. | ||
Step 29 | Complete the “DLP-G270 Verify the 32DMX or 40-DMX-C Power” to verify that the 40-DMX-C card is powered correctly. | ||
Step 30 | Display the 40-WSS-C card in card view. | ||
Step 31 | Click the Maintenance tab. | ||
Step 32 | For the circuit (channel) under test, click the Operating Mode table cell and choose Not Assigned from the drop-down list. | ||
Step 33 | Click Apply, then click Yes. | ||
Step 34 | Click the tabs, where n = the optical connector number that carries the wavelength under test. | ||
Step 35 | Click the Admin State table cell. Choose IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) from the drop-down list for all ports that were changed to OOS,MT or Locked,maintenance in steps 12 and 13 of this procedure. For example, if the tested wavelength is 1430-33 nm (shown as 1530.3), you would click the Admin State field and choose IS,ANSI (ANSI) or Unlocked,AutomaticInService (ETSI) from the drop-down list for both Port 1 (CHAN-RX) and Port 41 (PASS-THROUGH). | ||
Step 36 | Repeat steps 8 through 35 for the remaining 39 wavelengths of the 100-Ghz grid to verify the correct behavior of all VOAs inside the 40-WSS-C card. | ||
Step 37 | Disconnect the TXP card or tunable laser from the 40-WSS-C card. | ||
Step 38 | Remove the loopback created in Step 5. | ||
Step 39 | Complete the NTP-G37 Running Automatic Node Setup to restore the original configuration. | ||
Step 40 | Click the
Alarms tab.
|
NTP-G43 Performing the ROADM Node with 32WSS and 32DMX Cards Acceptance Test
![]() Note |
|
Step 1 | Display the ROADM node in node view (single-shelf mode) or multishelf view (multishelf mode). |
Step 2 | Import the Xml file to fully configure node: layout, patchcords, parameters. See the NTP-G143 Importing the Cisco Transport Planner NE Update Configuration File as necessary. |
Step 3 | Install the cards and fiber up the node according with the xml file settings. |
Step 4 | Run the ANS at node level and verify no errors are present. See NTP-G37 Running Automatic Node Setup task as necessary. In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Verify that all statuses under Link Status are either Success - Changed, or Success - Unchanged. If any are not, complete the following step: NTP-G37 Running Automatic Node Setup task. |
Step 5 | Create the OSC channels using the NTP-G38 Provisioning OSC Terminations task chapter. |
Step 6 | Click the
Alarms tab.
|
Step 7 | Complete the “DLP-G310 Verifying ROADM Node C-Band Pass-Through Channels with 32WSS and 40-WSS-C Cards” task. |
Step 8 | Complete the DLP-G311 Verifying the Side A or Side B ROADM C-Band Add/Drop Channels with 32WSS and 40-WSS-C Cards tasks for channels that will be added or dropped on the node. |
Step 9 | Delete both OSC channels using the “DLP-G186 Delete an OSC Termination” task. |
Step 10 | Complete the NTP-G37 Running Automatic Node Setup task. |
Step 11 | Create the two OSC channels using the NTP-G38 Provisioning OSC Terminations task. |
Step 12 | Click the
Alarms tab.
|
DLP-G310 Verifying ROADM Node C-Band Pass-Through Channels with 32WSS and 40-WSS-C Cards
![]() Note | Throughout this task, Side A refers to Slots 1 through 8, and Side B refers to Slots 10 through 17. |
Step 1 | Create a physical loopback on
the Side A OPT-BST, OPT-BST-E, or OSC-CSM card by connecting the LINE TX port
to its LINE RX port. For OPT-BST or OPT-BST-E cards, connect a 10-dB bulk
attenuator to the fiber. (OSC-CSM cards do not require attenuation.)
| ||
Step 2 | If an OPT-PRE amplifier or
OSC-CSM card is installed on Side A (where the physical loopback was created),
perform the following steps. If not, continue with
step 3.
| ||
Step 3 | If an OPT-PRE or OSC-CSM card
is installed on Side B, complete the following steps. If not, continue with
step 4.
| ||
Step 4 | Wait 2 to 3 minutes, then in
node view (single-shelf mode) or multishelf view (multishelf mode) click the
Alarms tab. Verify that the LOS alarms on the Side A OSCM or
OSC-CSM card and the OPT-BST or OPT-BST-E card have cleared. The clearing of
the LOS alarms indicates that the OSC link is active on Side A. If the alarms
do not clear, contact your next level of support.
| ||
Step 5 | Create an OCH-DCN circuit for channel 1 on side A related to EXP path. The circuit is bidirectional and goes from LINE-RX port of the OPT-BST (or OSC-CSM) side B to the LINE-TX port of the OPT-BST (or OSC-CSM) on the opposite side A. | ||
Step 6 | Connect the tunable laser
transmitter or the TXP_MR_10E_C card TRUNK-TX port to the Side B OPT-BST,
OPT-BST-E, or OSC-CSM LINE RX port. If a Side B OPT-PRE is installed, insert a
10-dB attenuator on the fiber coming from the TXP_MR_10E_C card.
| ||
Step 7 | If you are using a tunable laser, follow the manufacturer’s instructions to complete the following steps. If you are using a TXP_MR_10E_C card, continue with step 8. | ||
Step 8 | If you are using a TXP_MR_10E_C card, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task for the TXP transmitting the wavelength you will test. | ||
Step 9 | If an OPT-PRE card is
installed on Side B, complete the following steps. If not, continue with
step 10.
| ||
Step 10 | If an MMU card is
installed on Side B, complete the following steps, then continue with
step 12. If an MMU
card is not installed, continue with
step 11.
| ||
Step 11 | Verify the Side B 32WSS or
40-WSS-C card to OPT-BST, OPT-PRE, or OSC-CSM card cable connection:
| ||
Step 12 | Verify the EXPRESS cable
connection between the two 32WSS or two 40-WSS-C cards:
| ||
Step 13 | Display the Side A 32WSS or 40-WSS-C card in card view. Click the tabs, where n = the connector number containing the wavelength you are testing. Refer to Table 2, if needed. Wait 60 to 70 seconds (or click Reset), then locate the Power and VOA Power Ref parameters for the tested PASS-THROUGH port. Verify that the Power value is equal to the VOA Power Ref value, +/– 1.5 dBm. If the Power value is not equal to the VOA Power Ref value +/–1.5 dBm, contact your next level of support. | ||
Step 14 | If an MMU card is
installed on Side A, complete the following steps. If an MMU card is not
installed on Side A, continue with
step 15.
| ||
Step 15 | For OPT-BST, OPT-BST-E, or
OSC-CSM card is installed on Side A, complete the following steps.
| ||
Step 16 | If on Side A an OPT-BST or OPT-BST-E card is installed, complete the DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power task. If instead an OSC-CSM is installed, no action is needed. | ||
Step 17 | Repeat steps from 9 to 16 for the same wavelength running on opposite direction (side A-> side B). | ||
Step 18 | Complete step 13 for the additional wavelengths that you want to test. If you have tested all the wavelengths, continue with step 19. | ||
Step 19 | Delete the OCH-DCN circuit created on step 5. | ||
Step 20 | If you used a tunable laser or an installed TXP_MR_10E_C card for this test, disconnect it from the Side A OPT-BST, OPT-BST-E, or OSC-CSM line side RX ports. | ||
Step 21 | Remove the loopback fiber from the line RX and TX in the Side A OPT-BST, OPT-BST-E, or OSC-CSM card. | ||
Step 22 | Return to your originating procedure (NTP). |
DLP-G311 Verifying the Side A or Side B ROADM C-Band Add/Drop Channels with 32WSS and 40-WSS-C Cards
This task verifies the signal flow through Side A or Side B of a ROADM node for C-band add/drop channels. |
|
Step 1 | In node view (single-shelf mode) or multishelf view (multishelf mode), display the Alarms tab. | ||
Step 2 | Create a physical loopback on
the Side X OPT-BST, OPT-BST-E, or OSC-CSM card by connecting the LINE TX port
to its LINE RX port. For OPT-BST or OPT-BST-E cards, connect a 10-dB bulk
attenuator to the fiber. (OSC-CSM cards do not require attenuation.)
| ||
Step 3 | Wait 2 to 3 minutes, then
click the
Alarms
tab. Verify that the LOS alarms on the Side X OSCM or
OSC-CSM card and the OPT-BST or OPT-BST-E card have cleared. The clearing of
the LOS alarms indicates that the OSC link is active on Side X.
| ||
Step 4 | Create an OCH-DCN circuit for channel 1 on Side X related to ADD/DROP path. The circuit is bidirectional and goes from CHAN-RX port (Add) of the 32WSS or 40-WSS-C Side X to the LINE-TX port of the OPT-BST (or OSC-CSM) on the same side and backward from LINE-RX port of the OPT-BST (or OSC-CSM) on Side Y to the CHAN-TX port (Drop) of the 32DMX or 40-WSS-C card belonging to Side X. | ||
Step 5 | If you are using a tunable laser, follow the manufacturer’s instructions to complete the following steps. If you are using a TXP_MR_10E_C card, continue with . | ||
Step 6 | If you are using a TXP_MR_10E_C card, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task for the TXP transmitting the wavelength you will test. Refer to the table 42 10G Data Muxponder Card Settings in "Provision Transponder and Muxponder Cards" chapter, if needed. | ||
Step 7 | If you are using a TXP_MR_10E_C card, complete the following steps. If you are using a tunable laser continue with step 8. | ||
Step 8 | Connect the tunable laser transmitter or the TXP_MR_10E_C card DWDM TX port to the Side X fiber patch panel MUX port that is connected to the Side X 32WSS or 40-WSS-C card CHAN RX port carrying the tested wavelength. (If the TXP_MR_10E_C card was installed during Turn Up a Node chapter, simply verify the cable connection.) | ||
Step 9 | Connect the TXP_MR_10E_C DWDM RX port or the power meter RX port to the Side X fiber patch panel DMX port that is connected with the Side X 32DMX or 40-DMX-C card CHAN-TX port carrying the tested wavelength. (If the TXP_MR_10E_C card was installed during Turn Up a Node chapter, simply verify the cable connection.) | ||
Step 10 | Click the tabs, where n = the optical connector number that carries the wavelengths you will test. Refer to table 42 10G Data Muxponder Card Settings in "Provision Transponder and Muxponder Cards" chapter, if needed. | ||
Step 11 | Find the tested wavelength CHAN RX port, then scroll to the right until you see the Power Add parameter. Verify that the Power Add value for the tested port CHAN RX is equal to the output power level of the tunable laser or the TXP_MR_10E_C card measured in step 7, +/– 1.0 dBm. | ||
Step 12 | Click the tabs and record the value in the Power table cell for Port 67 (COM-TX) for the wavelength under test. | ||
Step 13 | Verify that the power value
from step 12 reaches the
Shelf
i Slot
i (32WSS or
40-WSS-C).Port COM-TX. Power set point +/– 1.0 dBm on Side X. To view this set
point:
| ||
Step 14 | If an MMU card is installed
on Side X, complete the following steps. If an MMU card is not installed on
Side X, continue with
step 15.
| ||
Step 15 | Verify the connection
between the 32WSS or 40-WSS-C card and the OPT-BST, OPT-BST-E or OSC-CSM cards:
| ||
Step 16 | If an OPT-PRE card is
installed on Side X, complete the following steps. If not, continue with
step 17.
| ||
Step 17 | If an MMU card is
installed on Side X, complete the following steps. If an MMU card is not
installed on Side X, continue with
Step 18.
| ||
Step 18 | Verify the connection
between the Side X 32WSS or 40-WSS-C card and the OPT-BST, OPT-BST-E, OPT-PRE,
or OSC-CSM card:
| ||
Step 19 | Verify the Side X 32WSS or
40-WSS-C and 32DMX or 40-DMX-C connection:
| ||
Step 20 | Display the Side X 32DMX or 40-DMX-C card in card view. | ||
Step 21 | Click the tab. Record the CHAN-TX port value under the Power parameter for the wavelength under test. | ||
Step 22 | Verify that the power value
from
step 21 reaches the
Shelf
i Slot
i (32DMX or
40-DMX-C).Port CHAN-TX.Power set point +/– 2 dBm on Side X. To view this set
point:
| ||
Step 23 | If you are using a TXP_MR_10E_C card, display it in card view. If not, read the values called for in Step 25 from the optical test set or tunable laser you are using. | ||
Step 24 | Click the tabs. | ||
Step 25 | In the Port 2 (Trunk)
column, locate the RX Optical Power value. Verify that the value matches the
power recorded in
Step 21, +/– 2 dBm.
If the power values do not match (+/– 2 dBm), complete the following steps:
| ||
Step 26 | Repeat Steps 5 through 25 for the remaining wavelengths. | ||
Step 27 | Delete the OCH-DCN circuit created on Step 4. | ||
Step 28 | If you used a tunable laser or installed a TXP_MR_10E_C card for this test, disconnect it from the Side X patch panel. | ||
Step 29 | Unplug the physical loopback fiber from the line TX and RX in the OPT-BST, OPT-BST-E, or OSC-CSM card. | ||
Step 30 | Return to your originating procedure (NTP). |
NTP-G180 Performing the ROADM Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test
![]() Note |
|
Step 1 | Make a copy of Table 2 and place it in a convenient location for reference throughout this procedure. The table shows the 40-WSS-C ports and the wavelengths assigned to them. The 40 wavelengths are divided among five physical multi-fiber push on (MPO) connectors on the 40-WSS-C card. Each MPO connector is assigned eight wavelengths. In Cisco Transport controller (CTC), the MPO connector appears in the card view Provisioning > Optical Chn:Optical Connector tab. Each Optical Connector subtab represents an MPO connector. Ports 1 through 40 are the channel (CHAN) RX (add) ports; Ports 41 through 80 are the pass-through ports. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 2 | Display the ROADM node in node view (single-shelf mode) or multishelf view (multishelf mode). | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 3 | Click the
Alarms tab.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 4 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Verify that all statuses under
Link Status are either Success - Changed or Success - Unchanged. If any are
not, complete the following steps:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 5 | If MMU cards are installed,
complete the following steps. If not, continue with
Step 6.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 6 | Display the Side B 40-WSS-C in card view. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 7 | Click the tabs, where n = the optical connector number that carries the wavelengths you will test. Refer to Table 15-2, if needed. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 8 | Click the Admin State table cell for the add port carrying the tested wavelength, then choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the drop-down list. For example, if the tested wavelength is 1530.33 nm (shown as 1530.3), you would click the Port 1 (CHAN-RX) Admin State field and choose OOS,MT or Locked,maintenance from the drop-down list. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 9 | Change the administrative
state of the pass-through port corresponding to the port in
Step 8 to
OOS,MT (ANSI)
or
Locked,maintenance (ETSI). For example, if the
tested wavelength is 1530.33 nm (shown as 1530.3), you would click the Port 33
(PASS-THROUGH) Admin State field and choose OOS,MT or Locked,maintenance from
the drop-down list. Refer to
Table 2, if needed.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 10 | Click Apply, then click Yes to confirm. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 11 | Repeat Steps 7 through 10 for each wavelength that you will test. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 12 | Display the Side A 40-WSS-C in card view. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 13 | Repeat Steps 7 through 11 for the Side A 40-WSS-C card. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 14 | Display the Side B 40-DMX-C card in card view and complete the following steps: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 15 | Repeat Step 14 for the Side A 40-DMX-C card. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 16 | Complete the “DLP-G310 Verifying ROADM Node C-Band Pass-Through Channels with 32WSS and 40-WSS-C Cards” task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 17 | Complete the following tasks for channels that will be added or dropped on the node. DLP-G311 Verifying the Side A or Side B ROADM C-Band Add/Drop Channels with 32WSS and 40-WSS-C Cards task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 18 | If MMU cards are installed,
complete the following steps. If not, continue with
Step 19.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 19 | Display the Side B 40-WSS-C in card view. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 20 | Click the tabs, where n = the optical connector number that carries the wavelengths you tested. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 21 | Click the Admin State table cell then choose IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) from the drop-down list for all ports that were changed to OOS,MT or Locked,Maintenance in Steps 8 and 9. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 22 | Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 23 | Repeat Steps 20 through 22 for all the ports that are in OOS,MT or Locked,maintenance state on the Side B 40-WSS-C card. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 24 | Display the Side A 40-WSS-C in card view. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 25 | Repeat Steps 20 through 22 for all ports on the Side A 40-WSS-C card. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 26 | Display the Side B 40-DMX-C in card view. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 27 | Choose the tabs. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 28 | For Port 33, click the Admin State table cell and choose IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) from the drop-down list. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 29 | Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 30 | Display the Side A 40-DMX-C card in card view. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 31 | Repeat Steps 27 through 29 for the Side A 40-DMX-C card. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 32 | Delete both OSC channels using the “DLP-G186 Delete an OSC Termination” task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 33 | Complete the NTP-G37 Running Automatic Node Setup task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 34 | Create the two OSC channels using the task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 35 | Click the
Alarms tab.
|
NTP-G276 Performing the 80-Channel n-degree ROADM Node Acceptance Tests
This procedure checks the power values and the optical connections for an 80 channel n-degree ROADM node. Use this test for both existing and new installations of 80 channel ROADM nodes. Use this procedure to also test the installation of a new side to a node. This procedure cannot be performed on the node on which the OPT-RAMP-C or OPT-RAMP-CE card is installed. |
|
|
|
![]() Note | Identify the sides that are already carrying traffic and the sides that are going to be tested. |
Step 1 | From the View menu, choose Go to Network View. | ||
Step 2 | Click the
Alarms tab.
| ||
Step 3 | Insert a full C-band tunable
transponder into an available slot on the side that you want to test.
| ||
Step 4 | Connect the TX port of the transponder to the EAD i (where i=1) port of the 80-WXC-C card on the side to be tested. | ||
Step 5 | Select a wavelength that is not already used by a side carrying traffic. Select 1530.33 nm for a new installation. Set the transponder wavelength to the selected wavelength yyyy.yy by completing the “DLP-G432 Setting the Transponder Wavelength” task. | ||
Step 6 | Place the trunk port of the transponder in the In-Service (IS) state. | ||
Step 7 | In node view, click the tabs and record the Power value of the COM port of the 80-WXC-C card for the side you are verifying. | ||
Step 8 | On Side
x, go to the card view of the 80-WXC-C card and
complete the following steps:
| ||
Step 9 | To check the
wavelengths for the EAD1 port, repeat from step 5 and step 8d for the remaining
79 wavelengths.
| ||
Step 10 | Disconnect the transponder from EAD i port and restore the fiber connection to the EAD i port. | ||
Step 11 | Repeat step 4 through step 10 for the remaining EAD i ports where i = 2 to 8. | ||
Step 12 | Plug a 15-dB LC attenuator into the trunk TX port of the transponder card. | ||
Step 13 | Select a wavelength that is not already used by a side carrying traffic. Select 1530.33 nm for a new installation. Set the transponder wavelength to the selected wavelength yyyy.yy by completing the “DLP-G432 Setting the Transponder Wavelength” task on page 15-123. | ||
Step 14 | Connect the optical power meter to the trunk TX port of the transponder card. | ||
Step 15 | Complete the “DLP-G433 Recordinging Transponder Optical Power” task. | ||
Step 16 | Disconnect the optical power meter from the TX port of the transponder card. | ||
Step 17 | In card view, display the OPT-AMP-C card configured as LINE for Side x (slot 1 or 17) and complete the following steps: | ||
Step 18 | Make the
following connections:
| ||
Step 19 | Create an OCHNC DCN circuit for wavelength yyyy.yy from LINE amplifier of Side x to local add/drop ports of the 80-WXC-C card of Side x using the DLP-G105 Provisioning Optical Channel Network Connections task and wait till all the alarms clear. | ||
Step 20 | In card view, display the booster amplifier card for Side x. Click the tabs and record the IL02 (LINE RX->COM TX) insertion loss value. | ||
Step 21 | In card view, display the transponder card and click the OOS,MT (ANSI) or Locked,maintenance (ETSI) from the Admin State drop-down list and click Apply. tabs. For the trunk port, choose | ||
Step 22 | In card view, display the booster amplifier card for Side x, and complete the following steps: | ||
Step 23 | In card view,
display the preamplifier card (OPT-AMP-C configured as PRE in slot 2 or 16) for
Side
x and complete the
following steps:
| ||
Step 24 | In card view,
display the 80-WXC-C card for Side
x and complete the
following steps:
| ||
Step 25 | In card view,
display the 80-WXC-C card for a side different from Side
x and complete the following steps:
This step must be performed for a single wavelength yyyy.yy only that is not used on any of the installed sides.
| ||
Step 26 | In card view,
display the booster amplifier card for Side
x, and complete the following:
| ||
Step 27 | Delete the OCHNC DCN circuit on wavelength yyyy.yy from LINE amplifier of Side x to local add/drop ports of the 80-WXC-C card of Side x using the DLP-G106 Deleting Optical Channel Network Connections task. | ||
Step 28 | In card view, display the transponder card and click the OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list and click Apply. tabs. For the trunk port, choose | ||
Step 29 | To test all wavelengths, repeat step 5 through step 28 for each wavelength. In step 5, set the wavelength to the next wavelength. | ||
Step 30 | Remove the fiber jumper connected between the DROP-TX port and the AD port in the 80-WXC-C card on Side x. | ||
Step 31 | Restore the original connections between the AD and DROP-TX ports of the 80-WXC-C card and the respective ports of the 15216 40 or 48-channel mux/demux patch panel according to the Cisco Transport Planner Internal Connections Report. | ||
Step 32 | Use a fiber jumper to connect the TX port to the RX port associated to the wavelength yyyy.yy to be tested in the 15216-MD-40-ODD, 15216-EF-40-ODD, or 15216-MD-48-ODD or in the 15216-MD-40-EVEN, 15216-EF-40-EVEN, or 15216-MD-48-EVEN unit for Side x (depending on which 15216 40 or 48-channel mux/demux patch panel the wavelength yyyy.yy is managed). | ||
Step 33 | Select a wavelength yyyy.yy on the full C band tunable transponder. Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder for the selected wavelength yyyy.yy. | ||
Step 34 | Create an OCHNC DCN circuit on wavelength yyyy.yy from LINE amplifier of side x to local add/drop ports of the 80-WXC-C card of Side x using the DLP-G105 Provisioning Optical Channel Network Connections task and wait till all the alarms clear on the node. | ||
Step 35 | In card view, display the 80-WXC-C card for Side x and complete the following steps: | ||
Step 36 | Delete the OCHNC DCN circuit on wavelength yyyy.yy from LINE amplifier of Side x to local add/drop ports of the 80-WXC-C card of Side x using theDLP-G106 Deleting Optical Channel Network Connections task. | ||
Step 37 | In card view, display the transponder card and click the OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list and click Apply. tabs. For the trunk port, choose | ||
Step 38 | Remove the fiber jumper that was connected in step 32 between the TX and RX ports associated to the tested wavelength yyyy.yy on the 15216-MD-40-ODD, 15216-EF-40-ODD, or 15216-MD-48-ODD or the 15216-MD-40-EVEN, 15216-EF-40-EVEN, or 15216-MD-48-EVEN unit for Side x. | ||
Step 39 | To verify all the 40 ports of the 15216-MD-40-ODD, 15216-EF-40-ODD, or 15216-MD-48-ODD unit and the 40 ports of the 15216-MD-40-EVEN, 15216-EF-40-EVEN, or 15216-MD-48-EVEN unit, repeat the previous steps from step 32 through step 37 by changing the wavelength yyyy.yy to cover all other 79 available wavelengths. | ||
Step 40 | Disconnect the optical power meter from the LINE-TX port of the booster amplifier of the Side x. | ||
Step 41 | Disconnect the transponder output port (with the 15-dB attenuator) from the LINE-RX port of the booster amplifier of the Side x. | ||
Step 42 | Repeat step 3 through step 41 for all the others sides that are being installed. | ||
Step 43 | In card view,
display the OPT-AMP-C card configured as LINE for Side
x (slot 1 or 17) and complete the following:
|
NTP-G44 Performing the Anti-ASE Hub Node Acceptance Test
A tunable laser or a TXP_MR_10E_C card |
|
Step 1 | From the View menu, choose Go to Network View. |
Step 2 | Click the
Alarms tab.
|
Step 3 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
Provisioning >
WDM-ANS >
Port Status tabs.
Verify that all statuses under Link Status are Success - Changed or
Success - Unchanged. If any are not, complete the following steps:
|
Step 4 | From your Cisco TransportPlanner site configuration file, identify the dropped and added channels that are configured in pass-through mode in both directions. |
Step 5 | Create a loopback on the Side A OPT-BST or OPT-BST-E amplifier by connecting a patchcord from the LINE TX port to the LINE RX port with a 10-dB bulk attenuator. |
Step 6 | Verify that the OSC link becomes active on the Side A OSCM or OSC-CSM card. (The OSC termination must already be provisioned. If not, complete the NTP-G38 Provisioning OSC Terminations task.) |
Step 7 | For pass-through channels, continue with Step 8. For add and drop channels, continue with Step 17. |
Step 8 | Verify the first channel
connection configured in pass-through mode in both directions:
|
Step 9 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task for the Side B OPT-PRE amplifier. |
Step 10 | Complete the “DLP-G269 Verifying the 32DMX-O or 40-DMX-C Card Power” task for the Side A 32MUX-O or 40-MUX-C cards. |
Step 11 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the Side A OPT-BST or OPT-BST-E amplifier. |
Step 12 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task for the Side A OPT-PRE amplifier. |
Step 13 | Complete the “DLP-G269 Verifying the 32DMX-O or 40-DMX-C Card Power” task for the Side A 32DMX-O or 40-DMX-C cards. |
Step 14 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the Side B OPT-BST or OPT-BST-E amplifier. |
Step 15 | Repeat Steps 8 through 14 for the remaining wavelengths on the 100-GHz grid that are pass-through wavelengths. |
Step 16 | If you have add and drop channels, continue with Step 17 to verify the channels. If not, continue with Step 29. |
Step 17 | Set the tunable laser or TXP_MR_10E_C card to the first wavelength of the 100-GHz ITU-T grid that is not a pass-through wavelength. Refer to the tunable laser manufacturer’s documentation or the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. |
Step 18 | Connect the tunable laser or TXP_MR_10E_C card to the CHAN RX nn port on the Side A 32MUX-O card, where nn is the first add or drop channel. |
Step 19 | Display the Side A 32MUX-O or 40-MUX-C card in card view. |
Step 20 | Click the tabs. |
Step 21 | Change the administrative state of Port nn to OOS,MT (ANSI) orLocked,maintenance (ETSI). |
Step 22 | Check that the power value on Port nn reaches the provisioned set point (VOA Power Ref). |
Step 23 | Display the Side A 32DMX-O/32DMX OR 40-DMX-C card in card view. |
Step 24 | Click the tabs. |
Step 25 | Change the administrative state of Port nn to OOS,MT (ANSI) orLocked,maintenance (ETSI). |
Step 26 | Check that the power value on Port nn reaches the provisioned set point (VOA Power Ref). |
Step 27 | Connect a power meter to the CHAN TX nn port through the patch panel and verify that the physical optical power coming out of drop Port nn on the Side A 32DMX-O/32DMX or 40-DMX-C card is consistent with the value read on the meter within 0.5 dB. |
Step 28 | Repeat Steps 17 through 27 for the remaining wavelengths on the 100-GHz grid that are not pass-through wavelengths. |
Step 29 | Remove the loopback connection on the Side A OPT-BST or OPT-BST-E card. |
Step 30 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. |
Step 31 | Create a loopback on the Side B OPT-BST or OPT-BST-E amplifier by connecting a patchcord from the LINE TX port to the LINE RX port with 10-dB bulk attenuator. |
Step 32 | Verify that the OSC link becomes active on the Side B OSCM card. (The OSC termination must be already provisioned. If not, complete the NTP-G38 Provisioning OSC Terminations task.) |
Step 33 | Repeat 17 through 30 for Side B add and drop cards. |
Step 34 | Remove the loopback on the Side B OPT-BST or OPT-BST-E card. |
Step 35 | Restore the default administrative state (IS,AINS/Unlocked,automaticInService) on all the ports previously set to OOS,MT (ANSI) orLocked,maintenance (ETSI). Stop. You have completed this procedure. |
NTP-G45 Performing the C-Band and L-Band Line Amplifier Node with OSCM Cards Acceptance Test
This procedure tests the C-band and L-band line amplifier node with OSCM cards installed on both the Side B and Side A sides of the shelf by looping a single wavelength through the shelf. |
|
![]() Note |
|
Step 1 | If you are using TXP_MR_10E_C cards, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” If not, continue with Step 2. | ||
Step 2 | From the View menu, choose Go to Home View. | ||
Step 3 | Click the
Alarms tab.
| ||
Step 4 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Verify that all statuses under
Link Status are listed as Success - Changed or Success - Unchanged. If any are
not, complete the following steps:
| ||
Step 5 | Create a loopback on the Side A OPT-BST or OPT-BST-E card by using a fiber with a 10-dB bulk attenuator to connect the LINE TX port to the LINE RX port. | ||
Step 6 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_C card, continue with
Step 7.
| ||
Step 7 | If you are using a TXP_MR_10E_C card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task, for the TXP transmitting the wavelength you will test. Refer to Table11-42 10G Data Muxponder Card Settings in "Provision Transponder and Muxponder Cards" chapter, if needed. | ||
Step 8 | Connect the tunable laser
transmitter, the TXP_MR_10E_C card, or DWDM TX port to the LINE RX port of the
Side B OPT-BST or OPT-BST-E card using a 10-dB bulk attenuator.
| ||
Step 9 | Wait 90 to 100 seconds, then
in node view (single-shelf mode) or multishelf view (multishelf mode) click the
Alarms tab.
Verify that the LOS alarms on the Side A OPT-BST or OPT-BST-E and OSCM cards
have cleared. The clearing of the LOS alarms indicates that the OSC link is
active on Side A.
| ||
Step 10 | If an OPT-PRE card or an OPT-AMP-L card (provisioned as an OPT-PRE) is installed on Side B, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. If not, continue with Step 11. | ||
Step 11 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the Side A OPT-BST or OPT-BST-E amplifier. | ||
Step 12 | If an OPT-PRE amplifier or an OPT-AMP-L amplifier (provisioned as an OPT-PRE) is installed on Side A, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. It not, continue with continue with Step 13. | ||
Step 13 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the Side B OPT-BST or OPT-BST-E amplifier. | ||
Step 14 | Disconnect the TXP card or tunable laser from the Side B OPT-BST or OPT-BST-E card. | ||
Step 15 | Remove the loopback on the Side A OPT-BST or OPT-BST-E card created in Step 5. | ||
Step 16 | Create a loopback on the Side B OPT-BST or OPT-BST-E card by connecting a patchcord from the LINE TX port to the LINE RX port with a 10-dB bulk attenuator. | ||
Step 17 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_C card, continue with
Step 18.
| ||
Step 18 | If you are using a TXP_MR_10E_C card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task, for the TXP transmitting the wavelength you will test. Refer to Table11-42 10G Data Muxponder Card Settings in "Provision Transponder and Muxponder Cards" chapter, if needed. | ||
Step 19 | Connect the tunable laser
transmitter, the TXP_MR_10E_C card, or DWDM TX port to the LINE RX port of the
Side A OPT-BST or OPT-BST-E card using a 10-dB bulk attenuator.
| ||
Step 20 | Wait 90 to 100 seconds,
then in node view (single-shelf mode) or multishelf view (multishelf mode)
click the
Alarms tab.
Verify that the LOS alarms on the Side B OPT-BST or OPT-BST-E card and the
Side B OSCM cards have cleared. The clearing of the LOS alarms indicates that
the OSC link is active on Side B.
| ||
Step 21 | If an OPT-PRE card or an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on Side A, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. If not, continue with Step 22. | ||
Step 22 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the Side B OPT-BST or OPT-BST-E amplifier. | ||
Step 23 | If an OPT-PRE amplifier or an OPT-AMP-L (provisioned in OPT-PRE mode) amplifier is installed on Side B, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. It not, continue with continue with Step 24. | ||
Step 24 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the Side A OPT-BST or OPT-BST-E amplifier. | ||
Step 25 | Disconnect the TXP or tunable laser from the Side A OPT-BST or OPT-BST-E card. | ||
Step 26 | Remove the loopback on the Side B OPT-BST or OPT-BST-E amplifier created in Step 16. | ||
Step 27 | Delete both OSC channels using the “DLP-G186 Delete an OSC Termination” task. | ||
Step 28 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 29 | Create the two OSC channels
using the
NTP-G38 Provisioning OSC
Terminations
task.
Stop. You have completed this procedure |
NTP-G46 Performing the C-Band Line Amplifier Node with OSC-CSM Cards Acceptance Test
This procedure tests a C-band line amplifier node with OSC-CSM cards installed on both Side B and Side A of the shelf by looping a single wavelength through the shelf. |
|
Step 1 | If you are using TXP_MR_10E_C cards, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. If not, continue with Step 2. | ||
Step 2 | From the View menu, choose Go to Home View. | ||
Step 3 | Click the
Alarms tab.
| ||
Step 4 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Verify that all statuses under
Link Status are listed as Success - Changed or Success - Unchanged. If any are
not, complete the following:
| ||
Step 5 | Create a physical loopback on
the Side A OSC-CSM card by connecting the LINE TX port to the LINE RX port with
a fiber and 10-dB bulk attenuator.
| ||
Step 6 | Wait 90 to 100 seconds, then
in node view (single-shelf mode) or multishelf view (multishelf mode) click the
Alarms tab.
Verify that the LOS alarm on the Side A OSC-CSM card has cleared. The clearing
of the LOS alarm indicates that the OSC link is active on Side A.
| ||
Step 7 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_C card, continue with
Step 8.
| ||
Step 8 | If you are using a TXP_MR_10E_C card, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task for the TXP containing the wavelength you will test. Refer to Table 1, if needed. | ||
Step 9 | Connect the tunable laser
transmitter or the TXP_MR_10E_C card DWDM TX port to the Side B OSC-CSM LINE RX
port using a 10-dB bulk attenuator.
| ||
Step 10 | If an OPT-PRE card is installed on Side B, complete the DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power task. If not, continue with Step 11. | ||
Step 11 | Display the Side A OSC-CSM card in card view. | ||
Step 12 | Click the tabs. Locate the Port 3 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the NTP-L22 Cleaning Fiber Connectors task. If this does not change the power value, consult your next level of support. | ||
Step 13 | If an OPT-PRE card is installed on Side A of the shelf, complete the DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power task. If not, continue with Step 14. | ||
Step 14 | Display the Side B OSC-CSM card in card view. | ||
Step 15 | Click the tabs. Locate the Port 2 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the NTP-L22 Cleaning Fiber Connectors task. If this does not change the power value, consult your next level of support. | ||
Step 16 | Disconnect the TXP or tunable laser from the Side B OSC-CSM card. | ||
Step 17 | Remove the physical loopback created on the Side A OSC-CSM card in Step 5. | ||
Step 18 | Create a loopback on the
Side B OSC-CSM card by connecting the LINE TX port with LINE RX port using a
patchcord and 10-dB bulk attenuator.
| ||
Step 19 | Wait 90 to 100 seconds,
then in node view (single-shelf mode) or multishelf view (multishelf mode)
click the
Alarms tab.
Verify that the LOS alarm on the Side B OSC-CSM card has cleared. The clearing
of the LOS alarm indicates that the OSC link is active on Side B.
| ||
Step 20 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_C card, continue with
Step 21.
| ||
Step 21 | If you are using a TXP_MR_10E_C card, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task for the TXP containing the wavelength you will test. Refer to Table 1, if needed. | ||
Step 22 | Connect the tunable laser
transmitter or the TXP_MR_10E_C card DWDM TX port to the Side A OSC-CSM LINE RX
port using a 10-dB bulk attenuator.
| ||
Step 23 | If an OPT-PRE card is installed on Side A, complete the DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power task. If not, continue with Step 24. | ||
Step 24 | Display the Side B OSC-CSM card in card view. | ||
Step 25 | Click the tabs. Locate the Port 3 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the NTP-L22 Cleaning Fiber Connectors task. If this does not change the power value, consult your next level of support. | ||
Step 26 | If an OPT-PRE is installed on Side B of the shelf, complete the DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power task for the Side B OPT-PRE amplifier. If not, continue with Step 27. | ||
Step 27 | Display the Side A OSC-CSM card in card view. | ||
Step 28 | Click the tabs and locate the Power value for Port 2. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the NTP-L22 Cleaning Fiber Connectors task. If this does not change the power value, consult your next level of support. | ||
Step 29 | Disconnect the TXP card or tunable laser from the Side A OSC-CSM card. | ||
Step 30 | Remove the loopback created on the Side B OSC-CSM card in Step 18. | ||
Step 31 | Delete both OSC channels. See the “DLP-G186 Delete an OSC Termination” task. | ||
Step 32 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 33 | Create the OSC channels
using the
NTP-G38 Provisioning OSC
Terminations
task.
Stop. You have completed this procedure. |
NTP-G156 Performing the L-Band Line Amplifier Node with OSC-CSM Cards Acceptance Test
This procedure tests a L-band line amplifier node with OSC-CSM cards installed on both Side B and Side A of the shelf by looping a single wavelength through the shelf. |
|
![]() Note | Optical power measurements require either a tunable laser or a multirate transponder to generate the proper optical wavelength. If multirate transponders were installed during completion of Turn Up a Node chapter, they can be used for this procedure. No additional cabling changes are needed. |
Step 1 | If you are using TXP_MR_10E_L cards, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task. If not, continue with Step 2. | ||
Step 2 | From the View menu, choose Go to Home View. | ||
Step 3 | Click the
Alarms tab.
| ||
Step 4 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Verify that all statuses under
Link Status are listed as Success - Changed or Success - Unchanged. If any are
not, complete the following:
| ||
Step 5 | Create a physical loopback on
the Side A OSC-CSM by connecting the LINE TX port to the LINE RX port with a
fiber and 10-dB bulk attenuator.
| ||
Step 6 | Wait 90 to 100 seconds, then
in node view (single-shelf mode) or multishelf view (multishelf mode) click the
Alarms tab.
Verify that the LOS alarm on the Side A OSC-CSM card has cleared. The clearing
of the LOS alarm indicates that the OSC link is active on Side A.
| ||
Step 7 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_L card, continue with
Step 8.
| ||
Step 8 | If you are using a TXP_MR_10E_L card, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task for the wavelength you will test. | ||
Step 9 | Connect the tunable laser
transmitter or the TXP_MR_10E_L card DWDM TX port to the Side B OSC-CSM LINE RX
port using a 10-dB bulk attenuator.
| ||
Step 10 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on Side B, complete the DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power task. If not, continue with Step 11. | ||
Step 11 | Display the Side A OSC-CSM card in card view. | ||
Step 12 | Click the tabs. Locate the Port 3 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the Cisco NCS 2000 Series Troubleshooting Guide task. If this does not change the power value, consult your next level of support. | ||
Step 13 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on Side A of the shelf, complete the DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power task. If not, continue with Step 14. | ||
Step 14 | Display the Side B OSC-CSM card in card view. | ||
Step 15 | Click the tabs. Locate the Port 2 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the Cisco NCS 2000 Series Troubleshooting Guide task. If this does not change the power value, consult your next level of support. | ||
Step 16 | Disconnect the TXP card or tunable laser from the Side B OSC-CSM card. | ||
Step 17 | Remove the physical loopback created on the Side A OSC-CSM card in Step 5. | ||
Step 18 | Create a loopback on the
Side B OSC-CSM by connecting the LINE TX port with LINE RX port using a
patchcord and 10-dB bulk attenuator.
| ||
Step 19 | Wait 90 to 100 seconds,
then in node view (single-shelf mode) or multishelf view (multishelf mode)
click the
Alarms tab.
Verify that the LOS alarm on the Side B OSC-CSM card has cleared. The clearing
of the LOS alarm indicates that the OSC link is active on Side B.
| ||
Step 20 | AlarmsIf you are using a
tunable laser, follow the manufacturer’s instructions to complete the following
steps. If you are using a TXP_MR_10E_L card, continue with
Step 21.
| ||
Step 21 | If you are using a TXP_MR_10E_L card, complete the DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing task for the wavelength you will test. | ||
Step 22 | Connect the tunable laser
transmitter or the TXP_MR_10E_L card DWDM TX port to the Side A OSC-CSM LINE RX
port using a 10-dB bulk attenuator.
| ||
Step 23 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on Side A, complete the DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power task. If not, continue with Step 24. | ||
Step 24 | Display the Side B OSC-CSM card in card view. | ||
Step 25 | Click the tabs. Locate the Port 3 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the Cisco NCS 2000 Series Troubleshooting Guide task. If this does not change the power value, consult your next level of support. | ||
Step 26 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on Side B, complete the DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power task. If not, continue with Step 27. | ||
Step 27 | Display the Side A OSC-CSM card in card view. | ||
Step 28 | Click the tabs and locate the Power value for Port 2. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the Cisco NCS 2000 Series Troubleshooting Guide task. If this does not change the power value, consult your next level of support. | ||
Step 29 | Disconnect the TXP card or tunable laser from the Side A OSC-CSM card. | ||
Step 30 | Remove the loopback created on the Side B OSC-CSM card in Step 18. | ||
Step 31 | Delete both OSC channels. See the “DLP-G186 Delete an OSC Termination” task. | ||
Step 32 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 33 | Create the OSC channels using the NTP-G38 Provisioning OSC Terminations task. |
NTP-G47 Performing the C-Band Line Amplifier Node with OSCM and OSC-CSM Cards Acceptance Test
![]() Note |
|
Step 1 | If you are using TXP_MR_10E_C cards, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. If not, continue with Step 2. | ||
Step 2 | Display the terminal node in node view (single-shelf mode) or multishelf view (multishelf mode). | ||
Step 3 | Click the
Alarms tab.
| ||
Step 4 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Verify that all statuses under
Link Status are listed as
Success
- Changed or
Success
- Unchanged. If any are not, complete the following:
| ||
Step 5 | Create a loopback on the
OSC-CSM card by connecting the LINE TX port to the LINE RX port using a
patchcord and 10-dB bulk attenuator.
| ||
Step 6 | Wait 90 to 100 seconds, then
in node view (single-shelf mode) or multishelf view (multishelf mode) click the
Alarms tab.
Verify that the LOS alarm on the OSC-CSM card has cleared. The clearing of the
LOS alarm indicates that the OSC link is active for this side of the shelf.
| ||
Step 7 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_C card, continue with
Step 8.
| ||
Step 8 | If you are using a TXP_MR_10E_C card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task for the TXP containing the wavelength you will test. Refer to Table 15-1 on page 15-40, if needed. | ||
Step 9 | Measure the TXP output power by connecting the TXP DWDM TX port to a test meter. Record the results for future reference. | ||
Step 10 | Connect the tunable laser
transmitter or the TXP_MR_10E_C card DWDM TX port to the OPT-BST or OPT-BST-E
LINE RX port using a fiber patchcord and 10-dB bulk attenuator.
| ||
Step 11 | If an OPT-PRE card is installed on the side opposite the OSC-CSM, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. If not, continue with Step 12. | ||
Step 12 | Display the OSC-CSM card in card view. | ||
Step 13 | Click the tabs and locate the Port 2 (COM-RX) Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the NTP-L22 Cleaning Fiber Connectors task. If this does not change the power value, consult your next level of support. | ||
Step 14 | If an OPT-PRE card is installed on the same Side As the OSC-CSM, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. If not, continue with Step 15. | ||
Step 15 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the OPT-BST or OPT-BST-E card. | ||
Step 16 | Disconnect the TXP or tunable laser from the OPT-BST or OPT-BST-E card. | ||
Step 17 | Remove the loopback fiber on the OSC-CSM card. | ||
Step 18 | Delete both OSC channels. See the “DLP-G186 Delete an OSC Termination” task. | ||
Step 19 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 20 | Create the OSC channels using the NTP-G38 Provisioning OSC Terminations task. | ||
Step 21 | Create a loopback on the OPT-BST or OPT-BST-E card by connecting the LINE TX port with LINE RX port using a patchcord and 10-dB bulk attenuator. | ||
Step 22 | Wait 90 to 100 seconds,
then in node view (single-shelf mode) or multishelf view (multishelf mode)
click the
Alarms tab.
Verify that the LOS alarms on the OPT-BST or OPT-BST-E card and the OSCM card
have cleared. The clearing of the LOS alarms indicates that the OSC link is
active for this side of the shelf.
| ||
Step 23 | Connect the tunable laser transmitter or the TXP_MR_10E_C card DWDM TX port to the OSC-CSM LINE RX port using a fiber patchcord and 10-dB bulk attenuator. | ||
Step 24 | If an OPT-PRE is installed on the same side of the shelf as the OSC-CSM, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. If not, continue with Step 25. | ||
Step 25 | Complete the “DLP-G79 Verifying the OPT-BST, OPT-BST-E, or OPT-BST-L Amplifier Laser and Power” task for the OPT-BST or OPT-BST-E card. | ||
Step 26 | Display the OSC-CSM card in card view. | ||
Step 27 | Click the tabs. Verify that the power value on Port 3 (COM-TX) is equal to the optical power from the tunable laser or TXP_MR_10E_C card (measured in Step 9) –10 dB, +/– 2 dB. If not, check your connections and clean the fibers using the NTP-L22 Cleaning Fiber Connectors task. If this does not change the power value, consult your next level of support. | ||
Step 28 | If an OPT-PRE card is installed on the side opposite the OSC-CSM, complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task. If not, continue with Step 29. | ||
Step 29 | Disconnect the TXP or tunable laser from the OSC-CSM card. | ||
Step 30 | Remove the loopback fiber on the OPT-BST or OPT-BST-E amplifier card. | ||
Step 31 | Delete both OSC channels. See the “DLP-G186 Delete an OSC Termination” task. | ||
Step 32 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 33 | Create the OSC channels using the NTP-G38 Provisioning OSC Terminations task. Stop. You have completed this procedure. |
NTP-G157 Performing the L-Band Line Amplifier Node with OSCM and OSC-CSM Cards Acceptance Test
This procedure tests a L-band line amplifier node with an OSC-CSM card installed on one side of the shelf and an OSCM card installed on the other. |
|
![]() Note | Optical power measurements require either a tunable laser or a multirate transponder to generate the proper optical wavelength. If multirate transponders were installed during completion of Chapter 14, Turn Up a Node task they can be used for this procedure. No additional cabling changes are needed. |
Step 1 | If you are using TXP_MR_10E_L cards, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. If not, continue with Step 2. | ||
Step 2 | From the View menu, choose Go to Home View. | ||
Step 3 | Click the
Alarms tab.
| ||
Step 4 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Verify that all statuses under
Link Status are listed as
Success
- Changed or
Success
- Unchanged. If any are not, complete the following:
| ||
Step 5 | Create a loopback on the
OSC-CSM card by connecting the LINE TX port to the LINE RX port using a fiber
patchcord and 10-dB bulk attenuator.
| ||
Step 6 | Wait 90 to 100 seconds, then
in node view (single-shelf mode) or multishelf view (multishelf mode) click the
Alarms tab.
Verify that the LOS alarm on the OSC-CSM card has cleared. The clearing of the
LOS alarm indicates that the OSC link is active for this side of the shelf.
| ||
Step 7 | If you are using a tunable
laser, follow the manufacturer’s instructions to complete the following steps.
If you are using a TXP_MR_10E_L card, continue with
Step 8.
| ||
Step 8 | If you are using a TXP_MR_10E_L card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task for the wavelength you will test. | ||
Step 9 | Measure the TXP card output power by connecting the TXP card DWDM TX port to a test meter. Record the results for future reference. | ||
Step 10 | Connect the tunable laser
transmitter or the TXP_MR_10E_L card DWDM TX port to the OPT-BST-L LINE RX port
using a 10-dB bulk attenuator.
| ||
Step 11 | Display the OPT-BST-L card in card view. | ||
Step 12 | Click the tabs. Verify that the power value on Port 2 (Out Com) is equal to the optical power from the tunable laser or TXP_MR_10E_L card (measured in Step 9), +/– 1.0 dBm. | ||
Step 13 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on the side opposite the OSC-CSM card, complete the “DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power” task. If not, continue with Step 14. | ||
Step 14 | Display the OSC-CSM card in card view. | ||
Step 15 | Click the tabs and locate the Port 3 Power value. Verify that the value is higher than –30 dBm. If the power value is not higher than –30 dBm, check your connections and clean the fibers using the “NTP-L22 Cleaning Fiber Connectors” procedure in the Cisco NCS 2000 Series Hardware Installation Guide. If this does not change the power value, consult your next level of support. | ||
Step 16 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on the same Side As the OSC-CSM, complete the “DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power” task. If not, continue with Step 17. | ||
Step 17 | Complete the DLP-G359 Verifying the OPT-BST-L or OPT-AMP-L (OPT-Line Mode) Amplifier Laser and Power for the OPT-BST-L card. | ||
Step 18 | Disconnect the TXP card or tunable laser from the OPT-BST-L card. | ||
Step 19 | Remove the loopback fiber on the OSC-CSM card. | ||
Step 20 | Delete both OSC channels. See the “DLP-G186 Delete an OSC Termination” task. | ||
Step 21 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 22 | Create the OSC channels using the NTP-G38 Provisioning OSC Terminations task. | ||
Step 23 | Create a loopback on the OPT-BST-L card by connecting the LINE TX port with LINE RX port using a patchcord and 10-dB bulk attenuator. | ||
Step 24 | Wait 90 to 100 seconds,
then in node view (single-shelf mode) or multishelf view (multishelf mode)
click the
Alarms tab.
Verify that the LOS alarms on the OPT-BST-L and OSCM cards have cleared. The
clearing of the LOS alarms indicates that the OSC link is active for this side
of the shelf.
| ||
Step 25 | Connect the tunable laser transmitter or the TXP_MR_10E_L card DWDM TX port to the OSC-CSM LINE RX port using a 10-dB bulk attenuator. | ||
Step 26 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on the same side of the shelf as the OSC-CSM, complete the “DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power” task. If not, continue with Step 27. | ||
Step 27 | Complete the DLP-G359 Verifying the OPT-BST-L or OPT-AMP-L (OPT-Line Mode) Amplifier Laser and Power for the OPT-BST-L card. | ||
Step 28 | Display the OSC-CSM card in card view. | ||
Step 29 | Click the tabs. Verify that the power value on Port 3 (Out Com) is equal to the optical power from the tunable laser or TXP_MR_10E_L card (measured in Step 9), +/– 1.0 dBm. | ||
Step 30 | If an OPT-AMP-L card (provisioned in OPT-PRE mode) is installed on the side opposite the OSC-CSM, complete the “DLP-G360 Verifying the OPT-AMP-L (OPT-PRE Mode) Amplifier Laser and Power” task. If not, continue with step 31. | ||
Step 31 | Disconnect the TXP card or tunable laser from the OSC-CSM card. | ||
Step 32 | Remove the loopback fiber on the OPT-BST-L amplifier card. | ||
Step 33 | Delete both OSC channels. See the “DLP-G186 Delete an OSC Termination” task. | ||
Step 34 | Complete the NTP-G37 Running Automatic Node Setup task to restore the original configuration. | ||
Step 35 | Create the OSC channels using the NTP-G38 Provisioning OSC Terminations task. |
NTP-G49 Performing the Active OADM Node Acceptance Test on a Symmetric Node with OSC-CSM Cards
![]() Note | Optical power measurements require either a tunable laser or a multirate transponder to generate the proper optical wavelength. If multirate transponders were installed during completion of Turn Up a Node chapter, they can be used for this procedure. No additional cabling changes are needed. |
Step 1 | from the View menu, choose Go to Network View. | ||
Step 2 | Click the
Alarms tab.
| ||
Step 3 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Verify that all statuses under Link Status are Success - Changed or Success - Unchanged. If not, complete the NTP-G37 Running Automatic Node Setup task. | ||
Step 4 | Check the Cisco TransportPlanner site configuration file to verify the presence of added and dropped bands (including four channels at 100 GHz) configured in pass-through mode in either direction. | ||
Step 5 | If no bands are configured in pass-through mode, continue with Step 7. If a band is configured in pass-through mode, mark it and skip the related optical test for the express, add, and drop sections. Band pass-through connections are verified separately. | ||
Step 6 | Check the site configuration file from Cisco TransportPlanner to verify the presence of dropped or added channels configured in pass-through mode in either direction. | ||
Step 7 | If no channels are configured in pass-through mode, continue with Step 8. If a channel is configured in pass-through mode, mark it and skip the related optical test for the express, add, and drop sections. Channel pass-through connections are verified separately. | ||
Step 8 | Create a loopback on the Side A OSC-CSM card by connecting the LINE TX port to the LINE RX port using a patchcord and a 10-dB bulk attenuator. | ||
Step 9 | Verify that the OSC link
becomes active on the Side A OSC-CSM card. (The OSC termination must be already
provisioned. If not, complete the
NTP-G38 Provisioning OSC
Terminations
task.)
| ||
Step 10 | If the OSC link becomes
active, continue with
Step 11. If the OSC
link does not turn up, perform the following troubleshooting steps:
| ||
Step 11 | If the node has express bands or channels, complete the NTP-G86 Verifying Express Channel Connections on an OADM Node with OSC-CSM Cards“NTP-G86 Verifying Express Channel Connections on an OADM Node with OSC-CSM Cards” task. If the node does not have express bands or channels, continue with Step 12. | ||
Step 12 | If connections configured in pass-through mode are present (noted in Steps 5 and 7), complete the DLP-G89 Verifying OADM Node Pass-Through Channel Connections. If not, continue with Step 13. | ||
Step 13 | If connections have add/drop connections, complete the “DLP-G94 Verifying Add and Drop Connections on an OADM Node with OSC-CSM Cards” task. Stop. You have completed this procedure |
DLP-G86 Verifying Express Channel Connections on an OADM Node with OSC-CSM Cards
This task verifies the express channel connections for an OADM node with OSC-CSM cards during a node acceptance test. |
|
Step 1 | If you are using a tunable laser, set the output power to a nominal value, such as –3 dBm. If not, continue with step 2. | ||
Step 2 | Connect the tunable laser transmitter or the TXP_MR_10E_C card DWDM TX port to the LINE RX port of the Side B OSC-CSM card. | ||
Step 3 | If an OPT-PRE amplifier card is installed on Side B, install a 10-dB bulk attenuator on the COM RX port. | ||
Step 4 | Based on the Cisco TransportPlanner site configuration file, tune the tunable laser or TXP_MR_10E_C card to a wavelength (on the 100-GHz ITU-T grid) that runs on the express path of all AD-xB-xx.x and AD-xC-xx.x cards on the Side B-to-Side A and Side A-to-Side B directions. Refer to the tunable laser manufacturer’s documentation or the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. | ||
Step 5 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task for the OPT-PRE amplifier card installed on Side A. | ||
Step 6 | If AD-xB-xx.x cards are
installed on Side B, complete the
DLP-G87 Verifying the AD-xB-xx.x Output Express Power
for each Side B card. If not, continue with step 7.
| ||
Step 7 | If AD-xC-xx.x cards are installed on Side B, complete the DLP-G88 Verifying the AD-xC-xx.x Output Express Power“DLP-G88 Verifying the AD-xC-xx.x Output Express Power” task for each Side B card. If not, continue with step 8. | ||
Step 8 | If AD-xC-xx.x cards are installed on Side A, complete the DLP-G271 Verifying the AD-xC-xx.x Output Common Power“DLP-G271 Verifying the AD-xC-xx.x Output Common Power” task for each Side A card. If not, continue with step 9. | ||
Step 9 | If AD-xB-xx.x cards are installed on Side A, complete the DLP-G272 Verifying the AD-xB-xx.x Output Common Power“DLP-G272 Verifying the AD-xB-xx.x Output Common Power” task for each Side A card. If not, continue with step 10. | ||
Step 10 | Complete the “DLP-G83 Verifying the OSC-CSM Power on OADM Nodes” task for the OSC-CSM card installed on Side A. | ||
Step 11 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task for the OPT-PRE card installed on Side B. | ||
Step 12 | Repeat steps 6 through 11 for the AD-xB-xx.x and AD-xC-xx.x cards along the Side A-to-Side B direction. | ||
Step 13 | Return to your originating procedure (NTP). |
DLP-G83 Verifying the OSC-CSM Power on OADM Nodes
DLP-G94 Verifying Add and Drop Connections on an OADM Node with OSC-CSM Cards
This task verifies the add and drop channel connections for an OADM node with OSC-CSM cards installed. |
|
Step 1 | Based on the Cisco TransportPlanner site configuration file, tune the tunable laser or TXP_MR_10E_C card to a wavelength (belonging to the 100-GHz ITU-T grid) of the channel running on the first add path of the first Side A AD-xC-xx.x or Side A 4MD-xx.x card on the Side B-to-Side A direction. Refer to the tunable laser manufacturer’s documentation or the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. | ||
Step 2 | Connect the tunable laser transmitter or the TXP_MR_10E_C card DWDM TX port to the corresponding 15xx.x RX port (on the card front panel) of the Side A AD-xC-xx.x or 4MD-xx.x card. | ||
Step 3 | Verify the Side A AD-xC-xx.x
or 4MD-xx.x card (Side B-to-Side A):
| ||
Step 4 | Complete the “DLP-G80 Verifying the OPT-PRE Amplifier Laser and Power” task on the Side A OPT-PRE amplifier to verify that the added wavelength turns on the laser. | ||
Step 5 | If the add connection uses a 4MD-xx.x card, continue with Step 6. If the add connection uses an AD-xC-xx.x card, move to Step 10. | ||
Step 6 | Verify the Side A AD-xB-xx.x
card:
| ||
Step 7 | Display the related AD-xB-xx.x card (Side A-to-Side B direction) in card view. | ||
Step 8 | Change the administrative state of the drop BAND TX port related to the wavelength selected on the tunable laser to OOS,MT (ANSI) or Locked,maintenance (ETSI). | ||
Step 9 | (Optional) Connect a power meter to the proper 15xx.xx TX port on the front panel (the dual port compared with the port where the tunable laser is connected). Verify that the physical optical power value from that port is consistent with the value displayed on the Provisioning > Optical Chn > Parameters tab for the proper CHAN TX power value, +/– 0.5 dB. | ||
Step 10 | Verify the Side A AD-xC-xx.x
(Side A-to-Side B) card:
| ||
Step 11 | (Optional) Connect a power meter to the proper 15xx.xx TX port on the front panel (the dual port compared with the port where the tunable laser is connected). Verify that the physical optical power value from that port is consistent with the value on Provisioning > Optical Chn > Parameters tab for the proper CHAN TX power value, +/– 0.5 dB. | ||
Step 12 | Repeat steps 10 through 11 for all add paths of any Side A AD-xC-xx.x cards along the Side B-to-Side A direction. | ||
Step 13 | Remove the loopback on the Side A OSC-CSM card. | ||
Step 14 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. | ||
Step 15 | Click Launch ANS. | ||
Step 16 | Create a loopback on the Side B OSC-CSM card by connecting the OSC-CSM LINE RX and LINE TX ports using a patchcord and 10-dB bulk attenuator. | ||
Step 17 | Verify that the OSC link
becomes active on the Side A OSC-CSM card. (The OSC termination must be already
provisioned. If not, complete the
NTP-G38 Provisioning OSC
Terminations task.)
| ||
Step 18 | If the OSC link becomes
active, continue with Step 19. If the OSC link does not turn up, perform the
following troubleshooting steps:
| ||
Step 19 | Check the site configuration file from Cisco TransportPlanner and identify the wavelength (belonging to the 100 Ghz ITU-T grid) of the channel running on the first add path of the first AD-xC-xx.x or 4MD-xx.x card on the Side A-to-Side B direction. | ||
Step 20 | Connect the tunable laser to the corresponding 15xx.x RX port (on the card front panel) of the Side B AD-xC-xx.x or Side B 4MD-xx.x card. | ||
Step 21 | Repeat Steps 3 through 20, applying the steps to the Side B-to-Side A direction. | ||
Step 22 | Restore the default administrative state (IS,AINS/Unlocked,automaticInService) on all the ports previously set to OOS,MT (ANSI) or Locked,maintenance (ETSI). | ||
Step 23 | Complete the NTP-G37 Running Automatic Node Setup task to recover the correct node configuration. | ||
Step 24 | Return to your originating procedure (NTP). |
NTP-G50 Performing the Passive OADM Node Acceptance Test on a Symmetric Node with OSC-CSM Cards
This procedure checks the integrity of all the optical connections inside an OADM node with OSC-CSM cards and no OPT-BST or OPT-BST-E cards installed on Side B and Side A of the shelf. Three connection types are tested: |
|
A tunable laser or a TXP_MR_10E_C card |
|
![]() Note | Optical power measurements require either a tunable laser or a multirate transponder to generate the proper optical wavelength. If multirate transponders were installed during completion of Turn Up a Node chapter, they can be used for this procedure. No additional cabling changes are needed. |
Step 1 | From the View menu, choose Go to Network View. | ||
Step 2 | Click the
Alarms tab.
| ||
Step 3 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Verify that all statuses under Link Status are Success - Changed or Success - Unchanged. If not, complete the NTP-G37 Running Automatic Node Setup task. | ||
Step 4 | Check the Cisco
TransportPlanner site configuration file to verify the presence of a dropped or
added bands (including four channels at 100 GHz) configured in pass-through
mode in either direction.
| ||
Step 5 | If no bands are configured in pass-through mode, continue with Step 7. If a band is configured in pass-through mode, mark it and skip the related optical test for the express, add, and drop sections. Band pass-through connections are verified separately. | ||
Step 6 | Check the site configuration
file from Cisco TransportPlanner to verify the presence of dropped or added
channels configured in pass-through mode in either direction.
| ||
Step 7 | If no channels are configured in pass-through mode, continue with step 8. If a channel is configured in pass-through mode, mark it and skip the related optical test for the express, add, and drop sections. Channel pass-through connections are verified separately. | ||
Step 8 | Create a loopback on the Side A OSC-CSM card by connecting the LINE TX port to the LINE RX port using a patchcord and 10-dB bulk attenuator. | ||
Step 9 | Verify that the OSC link
becomes active on the Side A OSC-CSM card. (The OSC termination must be already
provisioned. If not, complete the NTP-G38 Provisioning OSC
Terminations task.)
| ||
Step 10 | If the OSC link becomes
active, continue with step 11. If the OSC link does not turn up, perform the
following troubleshooting steps:
| ||
Step 11 | If the node has express bands or channels, complete the “NTP-G86 Verifying Express Channel Connections on an OADM Node with OSC-CSM Cards” task. If the node does not have express bands or channels, continue with step 12. | ||
Step 12 | If connections configured in pass-through mode are present (noted in Steps 5 through 7), complete the DLP-G89 Verifying OADM Node Pass-Through Channel Connections “DLP-G89 Verifying OADM Node Pass-Through Channel Connections” task. If not, continue with step 13. | ||
Step 13 | If connections have add/drop connections, complete the “DLP-G94 Verifying Add and Drop Connections on an OADM Node with OSC-CSM Cards” task. Stop. You have completed this procedure |
NTP-G186 Performing the Four-Degree and Eight-Degree Mesh Patch Panel Acceptance Test
This procedure checks the insertion loss for a four-degree or eight-degree patch panel. |
|
1 fully-tunable transponder or tunable laser source with an LC patchcord 1 optical power meter with LC input connector 1 MPO-LC multicable (LC if the optical power meter has LC input) |
|
![]() Note | Optical power measurements require either a tunable laser or a multirate transponder to generate the proper optical wavelength. If multirate transponders were installed during completion of Turn Up a Node chapter, they can be used for this procedure. No additional cabling changes are needed. |
Step 1 | From the View menu, choose Go to Network View. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 2 | Click the
Alarms tab.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 3 | If you are installing a TXP_MR_10E_C card, complete the “DLP-G358 Provisioning TXP_MR_10E_L and TXP_MR_10E_C Cards for Acceptance Testing” task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 4 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder to a wavelength not used in any of the sides already carrying traffic (1530.33 nm, for example). | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 5 | Complete the “DLP-G433 Recordinging Transponder Optical Power” task. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 6 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 7 | Connect the transponder to the COM-RX A port of the four-degree or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 8 | In card view for the transponder card, click the tabs and choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 9 | Verify the COM-RX port power
results for Side A (Table 3).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 10 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 11 | Connect the transponder to the COM-RX B port of the four-degree or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 12 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 13 | Verify the COM-RX port
power results for Side B (Table 4).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 14 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 15 | Connect the transponder to the COM-RX C port of the four-degree or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 16 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 17 | Verify the COM-RX port
power results for Side C (Table 5).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 18 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 19 | Connect the transponder to the COM-RX D port of the four-degree or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 20 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 21 | Verify the COM-RX port
power results for Side D (Table 6).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 22 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 23 | If you are testing a four-degree patch panel, continue with Step 76. If you are testing an eight-degree patch panel, continue with Step 24. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 24 | Connect the transponder to the COM-RX E port of the eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 25 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 26 | Verify the COM-RX port
power results for Side E (Table 15-7).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 27 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 28 | Connect the transponder to the COM-RX F port of the eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 29 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 30 | Verify the COM-RX port
power results for Side F (Table 8).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 31 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 32 | Connect the transponder to the COM-RX G port of the eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 33 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 34 | Verify the COM-RX port
power results for Side G (Table 9).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 35 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 36 | Connect the transponder to the COM-RX H port of the eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 37 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 38 | Verify the COM-RX port
power results for Side H (Table 10).
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 39 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 40 | Connect the transponder to
the test access RX port of the four- or eight-degree patch panel.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 41 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 42 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP A TX port of the four- or eight-degree patch-panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 43 | Connect the optical power meter to the fan-out cable 1. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 44 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 45 | Verify the IL is less than 11dB for an 8-degree patch panel or less than 8dB for a 4-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 46 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP B TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 47 | Connect the optical power meter to the fan-out cable 2. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 48 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 49 | Verify the IL is less than 11dB for an 8-degree patch panel or less than 8dB for a 4-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 50 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP C TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 51 | Connect the optical power meter to the fan-out cable 3. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 52 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 53 | Verify the IL is less than 11dB for an 8-degree patch panel or less than 8dB for a 4-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 54 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP D TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 55 | Connect the optical power meter to the fan-out cable 4. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 56 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 57 | Verify the IL is less than 11dB for an 8-degree patch panel or less than 8dB for a 4-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 58 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP E TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 59 | Connect the optical power meter to the fan-out cable 5. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 60 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 61 | Verify the IL is less than 11dB for an 8-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 62 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP F TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 63 | Connect the optical power meter to the fan-out cable 6. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 64 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 65 | Verify the IL is less than 11dB for an 8-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 66 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP G TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 67 | Connect the optical power meter to the fan-out cable 7. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 68 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 69 | Verify the IL is less than 11dB for an 8-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 70 | Connect the MPO connector of the MPO-LC (FC or SC) multifiber fan-out to EXP H TX port of the four- or eight-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 71 | Connect the optical power meter to the fan-out cable 8. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 72 | Collect the actual reading from the optical power meter. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 73 | Verify the IL is less than 11dB for an 8-degree patch panel. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 74 | In card view for the transponder card, click the tabs and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 75 | Repeat Steps 40 through 74 for the right side Local Access RX port. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Step 76 | Complete the
“NTP-G188
Performing the Native Mesh Node Acceptance Test” task.
The tables below are used for verification in Steps 9 through 38 of this procedure. |
DLP-G432 Setting the Transponder Wavelength
Fully C-band tunable transponder or tunable laser source with an LC patchcord |
|
Step 1 | In card view, display the transponder card. |
Step 2 | Click the tabs. |
Step 3 | In the Wavelength field, choose the desired wavelength (C-Band, odd) from the drop-down list. |
Step 4 | Click Apply. |
Step 5 | Click the tabs and click Create to preprovision a pluggable port module (PPM), if necessary. |
Step 6 | Click Ok, then Apply. |
Step 7 | Return to your originating procedure (NTP). |
DLP-G433 Recordinging Transponder Optical Power
Fully C-band tunable transponder or tunable laser source with an LC patchcord |
|
Step 1 | Connect the optical power meter to the transponder output. |
Step 2 | Display card view for the transponder card. |
Step 3 | Click the tabs, and choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the Admin State drop-down list. |
Step 4 | Record the optical power meter value. |
Step 5 | Choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. |
Step 6 | Disconnect the optical power meter from the TX port of the transponder card. |
Step 7 | Return to your originating procedure (NTP). |
NTP-G187 Performing the Multiring Site Acceptance Test
This procedure checks the connections and the output power values for a multiring node. A multiring node connects two existing in-service two-sides ROADM nodes with two sides (each equipped with MMU cards). |
|
Fully C-band tunable transponder or tunable laser source 1 optical power meter with LC input connector 1 MPO-LC multicable (LC if the optical power meter has LC input) |
|
|
|
![]() Note | Optical power measurements require either a tunable laser or a multirate transponder to generate the proper optical wavelength. If multirate transponders were installed during completion of Turning Up a Node, they can be used for this procedure. No additional cabling changes are needed. |
Step 1 | From the View menu, choose Go to Network View. |
Step 2 | Click the
Alarms tab.
|
Step 3 | Insert a full C-band tunable transponder card into an available slot. |
Step 4 | Plug a 15 dB LC attenuator to the TX port of the transponder card. |
Step 5 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder to a wavelength yyyy.yy (1530.33 nm, for example). |
Step 6 | Complete the “DLP-G433 Recordinging Transponder Optical Power” task. |
Step 7 | Disconnect the optical power meter from the TX port of the transponder card. |
Step 8 | Make the following
connections:
|
Step 9 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Complete the
following:
|
Step 10 | In card view, display the transponder card and click the tabs. Choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. |
Step 11 | In card view, display the
40-WXC-C card for Side A and complete the following:
|
Step 12 | In card view, display the OPT-AMP-17 card for Side A and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value” task. |
Step 13 | In card view, display the
40-WXC-C card for Side B and complete the following:
|
Step 14 | In card view, display the OPT-AMP-17 card for Side B and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value” task. |
Step 15 | In card view, display the
40-WXC-C card for Side C and complete the following:
|
Step 16 | In card view, display the OPT-AMP-17 card for Side C and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value” task. |
Step 17 | In card view, display the
40-WXC-C card for Side D and complete the following:
|
Step 18 | In card view, display the OPT-AMP-17 card for Side D and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value” task. |
Step 19 | In card view, display the 40-WXC-C card for Side A and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 2. |
Step 20 | In card view, display the OPT-AMP-17 card for Side A and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value” task. |
Step 21 | Record the optical power meter value and verify that the optical power meter value matches the value recorded in the “DLP-G433 Recordinging Transponder Optical Power” task (+\– 1dB). |
Step 22 | In card view, display the 40-WXC-C card for Side A. Click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. Repeat for Sides B, C, and D of the 40-WXC-C card. |
Step 23 | To test all wavelengths, repeat Steps 5, 10, 17, and 19 for all supported wavelengths. |
Step 24 | In card view, display the transponder card and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. |
Step 25 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port for Side B of the 40-WXC-C card. |
Step 26 | Connect, using an LC-LC adapter, the patchcord from the COM-TX port with the patchcord in the COM-RX port for Side A of the 40-WXC-C card. |
Step 27 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder card to the wavelength set in Step 5. |
Step 28 | Connect the transponder card output port (with the 15-dB-attenuator) to the COM-RX port of the 40-WXC-C card for Side B. |
Step 29 | In card view, display the transponder card. Click the tabs, and choose IS (ANSI) or Unlocked(ETSI) from the Admin State drop-down list. |
Step 30 | Complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task for Sides C and D of the 40-WXC-C card. Set the Input Port on the tabs to 2. |
Step 31 | Complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task for Side B of the 40-WXC-C card. Set the Input Port on the tabs to 3. |
Step 32 | In card view, display the 40-WXC-C card for Side B. Click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. Repeat for Sides A, C, and D. |
Step 33 | To test all wavelengths, repeat Steps 27 through 32 (omit Step 28) for all supported wavelengths. |
Step 34 | In card view, display the transponder card. Click the tabs, and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. |
Step 35 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side C of the 40-WXC-C card. |
Step 36 | Connect, using an LC-LC adapter, the patchcord from the COM-TX port to the patchcord in the COM-RX port for Side B of the 40-WXC-C card. |
Step 37 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder card to the wavelength set in Step 5. |
Step 38 | Connect the transponder card output port (with the 15-dB attenuator) to the COM-RX port of the 40-WXC-C card for Side C. |
Step 39 | In card view for the transponder card, click the tabs and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. |
Step 40 | Complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task for Sides A and D of the 40-WXC-C card. Set the Input Port on the tabs to 3. |
Step 41 | Complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task for Side C of the 40-WXC-C card. Set the Input Port on the tabs to 4. |
Step 42 | In card view, display the 40-WXC-C card and click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. Repeat for Sides A, B, and D. |
Step 43 | To test all wavelengths, repeat Steps 37 through 42 (omit Step 38) for all supported wavelengths. |
Step 44 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side D of the 40-WXC-C card. |
Step 45 | Connect, using an LC-LC adapter, the patchcord from the COM-TX port to the patchcord in the COM-RX of Side C of the 40-WXC-C card. |
Step 46 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder card to the desired wavelength for testing. |
Step 47 | Connect the transponder card output port (with the 15-dB attenuator) to the COM-RX port of the 40-WXC-C card of Side D. |
Step 48 | In card view, display the transponder card. Click the tabs, and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. |
Step 49 | Complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task for Sides A and B of the 40-WXC-C card. Set the Input Port on the tabs to 4. |
Step 50 | Complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task for Side C of the 40-WXC-C card. Set the Input Port on the tabs to 1. |
Step 51 | In card view, display the 40-WXC-C card for Side D. Click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. Repeat for Sides A, B, and C of the 40-WXC-C card. |
Step 52 | To test all wavelengths, repeat Steps 46 through 51 for all supported wavelengths, except Step 47. |
Step 53 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Restore the values recorded in Step 9a for the following parameters: |
Step 54 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Click Launch ANS. |
Step 55 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side A of the 40-WXC-C card. |
Step 56 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side B of the 40-WXC-C card. |
Step 57 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side C of the 40-WXC-C card. |
Step 58 | Restore the connections to
the MMU cards of the eight sides using the patchcords tested in this procedure:
|
DLP-G434 Recording the OPT-AMP-17-C Power Value
Step 1 | In card view for the OPT-AMP-17 card for Side x, complete the following:
|
Step 2 | Return to your originating procedure (NTP). |
DLP-G435 Setting the 40-WXC-C OCHNC Parameters
DLP-G436 Recording the 40-WXC-C Power Value
This task records the power value of the 40-WXC-C card for a multiring configuration. |
|
DLP-G433 Recordinging Transponder Optical Power |
|
Step 1 | In card view for the 40-WXC-C card for Side x, complete the following:
|
Step 2 | Return to your originating procedure (NTP). |
NTP-G188 Performing the Native Mesh Node Acceptance Test
This procedure checks the power values and the optical connections for a native mesh node. Use this test for both new installations and directional upgrades of native mesh nodes. Use this to also test the installation of a new side n to a node. |
|
|
|
Step 1 | Identify the sides that are already carrying traffic and which sides are going to be tested. |
Step 2 | From the View menu, choose Go to Network View. |
Step 3 | Click the
Alarms tab.
|
Step 4 | Insert a full C-band tunable transponder into an available slot of the side that you want to test (Side A through H, referred to as Side x in this procedure). |
Step 5 | Plug a 15-dB LC attenuator into the trunk TX port of the transponder card. |
Step 6 | Select a wavelength that is not used on any of the sides for carrying traffic (or 1530.33 nm if it is a new installation). Complete the “DLP-G432 Setting the Transponder Wavelength” to tune the transponder for the selected wavelength yyyy.yy. |
Step 7 | Connect the optical power meter to the trunk TX port of the transponder card. |
Step 8 | Complete the “DLP-G433 Recordinging Transponder Optical Power”. |
Step 9 | Disconnect the optical power meter from the TX port of the transponder card. |
Step 10 | In card view, display the OSC-CSM or OSCM card for Side x and complete the following: |
Step 11 | Make the following
connections:
|
Step 12 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Complete the
following:
|
Step 13 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Click Launch ANS. |
Step 14 | In card view, display the 40-DMX-C card for Side x and complete the following: |
Step 15 | In card view, display the 40-MUX-C card for Side x. Click the tabs, and choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the Admin State drop-down list. Click Apply. |
Step 16 | In card view, display the booster amplifier card for Side x. Click the tabs and record the IL02 (LINE RX->COM TX) insertion loss value. |
Step 17 | In card view, display the transponder card and click the tabs. For trunk port, choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the Admin State drop-down list and click Apply. |
Step 18 | In card view, display the booster amplifier card for Side x, and complete the following: |
Step 19 | In card view, display the preamplifier card (OPT-PRE, OPT-AMP-C, or OPT-AMP-17C) for Side x and complete the following: |
Step 20 | In card view, display the
40-WXC-C card for Side x and complete the following:
|
Step 21 | In card view, display the
40-DMX-C card for Side x and complete the following:
|
Step 22 | In card view, display the
40-MUX-C card for Side x and complete the following:
|
Step 23 | In card view, display the
40-WXC-C card for Side x and complete the following:
|
Step 24 | In card view, display the
booster amplifier card for Side x, and complete the following:
|
Step 25 | Select the 40-WXC-C card on
Side
n where
n is A, B, C, D, E, F, G, or H but n is not equal to
x, go to the card view and complete the following:
|
Step 26 | Repeat Step 25 for all the others of Side n, where n is A, B, C, D, E, F, G, or H but n not equal to x. |
Step 27 | In card view, display the 40-WXC-C card for Side x and click the Maintenance > OCHNC tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. |
Step 28 | In card view, display the transponder card and click the tabs. For trunk port, choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. Click Apply. |
Step 29 | To test all wavelengths, repeat Step 6 through Step 28 for each wavelength. In Step 6, set the wavelength to the next odd wavelength. |
Step 30 | Disconnect the optical power meter from the LINE-TX port of the booster amplifier of the Side x. |
Step 31 | Disconnect the transponder output port (with the 15-dB attenuator) from the LINE-RX port of the booster amplifier of the Side x. |
Step 32 | In card view, display the 40-DMX-C card for Side x and click the Provisioning > Optical Line > Parameters tabs. Complete the following: |
Step 33 | In card view, display the 40-MUX-C card for Side x and click the Provisioning > Optical Line > Parameters tabs. Choose IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) from the Admin State drop-down list and click Apply. |
Step 34 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs and restore the values recorded in Step 12a for the following parameters: |
Step 35 | Repeat Steps 4 through 34 for all the others sides that are being installed. |
Step 36 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Click Launch ANS. Stop. You have completed this procedure. |
NTP-G189 Performing the Node Upgrade Acceptance Test
This procedure checks the connections and the output power values for a node in an upgraded ring. The upgraded node connects an existing in-service ROADM node with two sides (each equipped with MMU cards) to a native mesh node with two sides. |
|
Fully C-band tunable transponder or tunable laser source with an LC patchcord 1 optical power meter with LC input connector |
|
|
|
Step 1 | From the View menu, choose Go to Network View. |
Step 2 | Click the
Alarms tab.
|
Step 3 | Insert a full C-band tunable transponder into an available slot for the node that you want to test. |
Step 4 | Plug a 15-dB LC attenuator to the TX port of the transponder. |
Step 5 | Complete the “DLP-G432 Setting the Transponder Wavelength” to tune the transponder to a wavelength yyyy.yy that is not used in any of the sides already carrying traffic (or 1530.33 nm if it is a new installation). |
Step 6 | Complete the “DLP-G433 Recordinging Transponder Optical Power”. |
Step 7 | Disconnect the optical power meter from the TX port of the transponder card. |
Step 8 | Make the following
connections:
|
Step 9 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs. Complete the following:
|
Step 10 | Display card view for the OPT-AMP-17 card on Side A and click the tabs. From the Working Card Mode drop-down list, verify that OPT-PRE appears and if not, choose it. Click Apply. Repeat for Side B. |
Step 11 | Display card view for the transponder card and click the tabs. Choose IS (ANSI) or Unlocked(ETSI) from the Admin State drop-down list and click Apply. |
Step 12 | In card view, display the
40-WXC-C card of Side A and complete the following:
|
Step 13 | In card view, display the OPT-AMP-17 card for Side A and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value”. |
Step 14 | In card view, display the
40-WXC-C card for Side B and complete the following:
|
Step 15 | In card view, display the OPT-AMP-17 card for Side B and complete the “DLP-G434 Recording the OPT-AMP-17-C Power Value” task. |
Step 16 | In card view, display the 40-WXC-C for Side A and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 2. |
Step 17 | In card view, display the 40-WXC-C for Side C and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 1. |
Step 18 | In card view, display the 40-WXC-C for Side D and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 1. |
Step 19 | In card view, display the 40-WXC-C for Side A and click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. Repeat for Sides B, C, and D of the 40-WXC-C card. |
Step 20 | Display card view for the transponder card and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. |
Step 21 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side B of the 40-WXC-C card. |
Step 22 | Connect, using the LC-LC adapter, the patchcord from the COM-TX port with the patchcord in the COM-RX port for Side A of the 40-WXC-C card. |
Step 23 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder to the wavelength set in Step 5. |
Step 24 | Connect the transponder card output port (with the 15-dB attenuator) to the COM-RX port of the 40-WXC-C card on Side B. |
Step 25 | Display card view for the transponder card. Click the tabs, and choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list. |
Step 26 | In card view, display the 40-WXC-C card for Side A and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 2. |
Step 27 | In card view, display the 40-WXC-C for Side B and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 1. |
Step 28 | In card view, display the 40-WXC-C for Side C and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 2. |
Step 29 | In card view, display the 40-WXC-C for Side D and complete the “DLP-G435 Setting the 40-WXC-C OCHNC Parameters” task. Set the Input Port on the tabs to 2. |
Step 30 | In card view, display the 40-WXC-C for Side B and click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. Repeat for Sides A, C, and D of the 40-WXC-C card. |
Step 31 | Display the card view for the transponder card. Click the tabs, and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. |
Step 32 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Restore the values recorded in Step 9a for the following parameters: |
Step 33 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Click Launch ANS. |
Step 34 | Disconnect the patchcord in the COM-TX port from the patchcord in the COM-RX port of Side A of the 40-WXC-C card. |
Step 35 | Make the following
connections:
|
Step 36 | In node view (single-shelf
mode) or multishelf view (multishelf mode), click the
tabs and complete the following:
|
Step 37 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Click Launch ANS. |
Step 38 | In card view, display the 40-DMX-C card for Side C and complete the following: |
Step 39 | In card view, display the 40-MUX-C card for Side C and click the tabs. Choose OOS,MT (ANSI) or Locked,maintenance (ETSI) from the Admin State drop-down list and click Apply. |
Step 40 | In card view, display the booster amplifier card for Side C. Click the tabs and record the LINE-RX -> COM TX insertion loss. |
Step 41 | Display the transponder card in card view and click the tabs. Choose IS (ANSI) or Unlocked (ETSI) from the Admin State drop-down list and click Apply. |
Step 42 | In card view, display the
booster amplifier card for Side C and complete the following:
|
Step 43 | In card view, display the
preamplifier card for Side C and complete the following:
|
Step 44 | In card view, display the
40-WXC-C card for Side C and complete the following:
|
Step 45 | In card view, display the
40-DMX-C card for Side C and complete the following:
|
Step 46 | In card view, display the
40-MUX-C card for Side C and complete the following:
|
Step 47 | In card view, display the
40-WXC-C card for Side C, and complete the following:
|
Step 48 | In card view, display the
booster amplifier card for Side C, and complete the following:
|
Step 49 | In card view, display the 40-WXC-C card for Side C, and click the tabs. In the Return Value COM-TX on selected Wavelength area, click Refresh and then Delete. |
Step 50 | Display Side A of the
40-WXC-C card in card view, and complete the following:
|
Step 51 | Repeat Step 50 for the 40-WXC-C card of Side B. |
Step 52 | Repeat Step 50 for the 40-WXC-C card of Side D. |
Step 53 | Display card view for the transponder card and choose OOS,DSBLD (ANSI) or Locked,disabled (ETSI) from the Admin State drop-down list. |
Step 54 | Connect the transponder output port (with the 15-dB attenuator) to the Line RX port of the booster amplifier of Side D. |
Step 55 | Complete the “DLP-G432 Setting the Transponder Wavelength” task to tune the transponder to the next odd wavelength after yyyy.yy nm. |
Step 56 | Disconnect the patchcord between the client TX of lambda yyyy.yy from the client RX of lambda yyyy.yy on the Side C patch panel. Use this patchcord to connect the client TX of lambda yyyy.yy to the client RX of lambda yyyy.yy on the Side D patch panel. Note that yyyy.yy was recorded in Step 5. |
Step 57 | Repeat Steps 36 to 50 for Side D. |
Step 58 | Display Side A of the
40-WXC-C card in card view, and complete the following:
|
Step 59 | Repeat Step 58 for the 40-WXC-C card of Side B. |
Step 60 | Repeat Step 58 for the 40-WXC-C card of Side C. |
Step 61 | Disconnect the optical power meter from the LINE-TX port of the booster amplifier of Side D. |
Step 62 | Disconnect the transponder output port (with the 15-dB attenuator) from the LINE-RX port of the booster amplifier of the Side x. |
Step 63 | In card view, display the 40-DMX-C card for Side C, and complete the following: |
Step 64 | In card view, display the 40-MUX-C card for Side C and click the tabs. Choose IS,AINS (ANSI) or Unlocked,automaticInService (ETSI) from the Admin State drop-down list and click Apply. |
Step 65 | Repeat Steps 63 and 64 for Side D. |
Step 66 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs and restore the values recorded in Step 36a for the following parameters for Sides C and D: |
Step 67 | In node view (single-shelf mode) or multishelf view (multishelf mode), click the tabs. Click Launch ANS. |
Step 68 | Restore the connections to
the MMU cards of the four sides using the patchcords tested in this procedure:
|
NTP-G243 Performing the Two-Degree ROADM Node with 40-SMR-1-C and OPT-AMP-17-C Cards Acceptance Test
This procedure tests a two-degree ROADM node with 40-SMR-1-C and OPT-AMP-17-C cards installed. |
|
Step 1 | On the 40-SMR-1-C card on Side A, do the following steps: |
Step 2 | Retrieve the power set point
of the DROP-TX port of the 40-SMR-1-C card on Side A. To view this set point,
do the following:
|
Step 3 | Display the OPT-AMP-17-C on Side A in card view, and complete the following steps: |
Step 4 | Connect a tunable laser or a fully tunable TXP_DME_10E_C card to the LINE RX port of the OPT-AMP-17-C card on Side A. Connect a 10dB bulk attenuator to the fiber or regulate the output power of the tunable laser to -10dBm. |
Step 5 | Create an OCHNC DCN for channel 1 on Side A related to the ADD-DROP path using the DLP-G105 Provisioning Optical Channel Network Connections task. The circuit must be bidirectional connecting the ADD-RX port of the 40-SMR-1-C card to the LINE-TX port of the OPT-AMP-17-C card and vice-versa (LINE-RX port of the OPT-AMP-17-C card to the DROP-TX port of the 40-SMR-1-C card) |
Step 6 | Set the tunable laser or the TXP_DME_10E_C card to the first wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm) and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state. |
Step 7 | Verify the power levels of
channel 1 by performing the following steps:
|
Step 8 | Delete the OCHNC DCN circuit for channel 1 on Side A that is related to the ADD-DROP path created in Step 5 using the DLP-G106 Deleting Optical Channel Network Connections task. |
Step 9 | Create an OCHNC DCN circuit for channel 1 on Side A related to the EXP path using the DLP-G105 Provisioning Optical Channel Network Connections task. The circuit must be bidirectional and connects the LINE-RX port of the OPT-AMP-17-C card on Side A to the LINE-TX port of the OPT-AMP-17-C card on Side B. |
Step 10 | Verify the power levels of
channel 1 by performing the following steps:
|
Step 11 | Turn off the laser or place the trunk port of the TXP card in OutofService (OOS) state and delete the OCHNC DCN circuit on Side A related to channel 1 created in Step 9 using the DLP-G106 Deleting Optical Channel Network Connections task. |
Step 12 | Set the tunable laser or the TXP_DME_10E_C card to the second wavelength of the 100-GHz ITU-T C-band grid and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state. Repeat Step 5 through Step 11 for the second wavelength. |
Step 13 | Repeat Step 12 for the remaining 38 wavelengths on Side A. |
Step 14 | Delete the OCHNC DCN circuit related to channel 40 using the DLP-G106 Deleting Optical Channel Network Connections task, and turn off the laser or place the trunk port of the TXP_DME_10E_C card in OutofService (OOS) state. |
Step 15 | On the 40-SMR-1-C card on
Side A, do the following steps:
|
Step 16 | On the 15216-MD-40-ODD,
15216-EF-40-ODD, or 15216-MD-48-ODD unit on Side A, do the following steps:
|
Step 17 | Create an OCHNC DCN for channel 1 on Side A related to the ADD-DROP path as done in Step 5. |
Step 18 | Set the tunable laser or the TXP_DME_10E_C card to the first wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm) and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state. |
Step 19 | To verify the insertion
loss on the optical path of the 15216-MD-40-ODD, 15216-EF-40-ODD, or
15216-MD-48-ODD unit, do the following steps:
|
Step 20 | Turn off the laser or place the trunk port of the TXP card in OutofService (OOS) state and delete the OCHNC DCN circuit on Side A related to channel 1 using the DLP-G106 Deleting Optical Channel Network Connections task. |
Step 21 | Set the tunable laser or the TXP_DME_10E_C card to the next wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm) and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state and repeat Step 17 through Step 20 for the new wavelength. |
Step 22 | Restore the initial
configuration after checking all the 40 available wavelengths:
|
Step 23 | Repeat all the steps from Step 1 through Step 22 related to Side B. Stop. You have completed this procedure. |
NTP-G244 Performing the Four Degree ROADM Node with 40-SMR-2-C Cards Acceptance Test
This procedure tests a four-degree ROADM node with 40-SMR-2-C cards installed. |
|
Step 1 | On the 40-SMR-2-C card on Side A, do the following steps: |
Step 2 | Retrieve the power set point
of the DROP-TX port of the 40-SMR-2-C card on Side A. To view this set point,
do the following:
|
Step 3 | Display the 40-SMR-2-C card for Side A in card view and complete the following steps: |
Step 4 | Connect a tunable laser or a fully tunable TXP_DME_10E_C to the LINE RX port of the 40-SMR-2-C card on Side A. Connect a bulk attenuator to the fiber or regulate the output power of the tunable laser to -10dBm. |
Step 5 | Create an OCHNC DCN on Side A related to the ADD-DROP path of channel 1 using the DLP-G105 Provisioning Optical Channel Network Connections task. The circuit must be bidirectional connecting the ADD-RX port to the LINE-TX port of the 40-SMR-2-C card and vice-versa (LINE-RX port to the DROP-TX port of the 40-SMR-2-C card) |
Step 6 | Set the tunable laser or the TXP_DME_10E_C card to the first wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm) and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state. |
Step 7 | Verify the power levels of
channel 1 by performing the following steps:
|
Step 8 | Delete the OCHNC DCN circuit for channel 1 on Side A related to the ADD-DROP path that was created in Step 5 using the DLP-G106 Deleting Optical Channel Network Connections task. |
Step 9 | Create an OCHNC DCN circuit for channel 1 on Side A related to the EXP-TX path towards Side B using the DLP-G105 Provisioning Optical Channel Network Connections task. The circuit must be bidirectional and connects the LINE-RX port of the 40-SMR-2-C card on Side A to the LINE-TX port of the 40-SMR-2-C card on Side B. |
Step 10 | Verify the power levels of
channel 1 by performing the following steps:
|
Step 11 | Delete the OCHNC DCN circuit towards Side B related to channel 1 created in Step 9 using the DLP-G106 Deleting Optical Channel Network Connections task. |
Step 12 | Create the OCHNC DCN circuit for channel 1 on Side A related to EXP-TX path towards Side C using the DLP-G105 Provisioning Optical Channel Network Connections task. Repeat Step 10 and Step 11 for the circuit that is created. |
Step 13 | Repeat Step 12 towards Side D, turn off the laser or place the trunk port of the TXP_DME_10E_C card in OutofService (OOS) state. |
Step 14 | Set the tunable laser or the TXP_DME_10E_C card to the second wavelength of the 100-GHz ITU-T C-band grid and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state. Repeat Step 5 through Step 13 for the second wavelength. |
Step 15 | Repeat Step 14 for the remaining 38 wavelengths on Side A. |
Step 16 | Delete the OCHNC DCN circuit related to channel 40 using the DLP-G106 Deleting Optical Channel Network Connections task, and turn off the laser or place the trunk port of the TXP_DME_10E_C card in OutofService (OOS) state. |
Step 17 | On the 40-SMR-2-C card on
Side A, do the following steps:
|
Step 18 | On the15216-MD-40-ODD unit on Side A, do the following steps: |
Step 19 | Create an OCHNC DCN for channel 1 on Side A related to the ADD-DROP path as done in Step 5. |
Step 20 | Set the tunable laser or the TXP_DME_10E_C card to the first wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm) and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state. |
Step 21 | To verify the insertion
loss on the optical path of the 15216-MD-40-ODD unit on Side A, do the
following steps:
|
Step 22 | Turn off the laser or place the trunk port of the TXP_DME_10E_C card in OutofService (OOS) state and delete the OCHNC DCN circuit on Side A related to channel 1 using the DLP-G106 Deleting Optical Channel Network Connections task. |
Step 23 | Set the tunable laser or the TXP_DME_10E_C card to the next wavelength of the 100-GHz ITU-T C-band grid (1530.33 nm) and place the trunk port of the TXP_DME_10E_C card in the In-Service (IS) state and repeat Step 19 through Step 22 for the new wavelength. |
Step 24 | Restore the initial
configuration after checking all the 40 available wavelengths:
|
Step 25 | Repeat all the steps from Step 1 through Step 24 related to Side B. |
Step 26 | Repeat all the steps from Step 1 through Step 24 related to Side C. |
Step 27 | Repeat all the steps from Step 1 through Step 24 related to Side D. Stop. You have completed this procedure. |