Cisco Nexus 7000 Series NX-OS System Management Configuration Guide, Release 5.x
Configuring Online Diagnostics
Downloads: This chapterpdf (PDF - 195.0KB) The complete bookPDF (PDF - 9.3MB) | Feedback

Configuring Online Diagnostics

Table Of Contents

Configuring Online Diagnostics

Information About Online Diagnostics

Online Diagnostic Overview

Bootup Diagnostics

Runtime or Health Monitoring Diagnostics

On-Demand Diagnostics

High Availability

Virtualization Support

Licensing Requirements for Online Diagnostics

Prerequisites for Online Diagnostics

Guidelines and Limitations

Default Settings

Configuring Online Diagnostics

Setting the Bootup Diagnostic Level

Activating a Diagnostic Test

Setting a Diagnostic Test as Inactive

Starting or Stopping an On-Demand Diagnostic Test

Clearing Diagnostic Results

Simulating Diagnostic Results

Verifying the Online Diagnostics Configuration

Configuration Examples for Online Diagnostics

Additional References

Related Documents

Standards

Feature History for Online Diagnostics


Configuring Online Diagnostics


This chapter describes how to configure the generic online diagnostics (GOLD) feature on Cisco NX-OS devices.

This chapter includes the following sections:

Information About Online Diagnostics

Licensing Requirements for Online Diagnostics

Prerequisites for Online Diagnostics

Guidelines and Limitations

Default Settings

Configuring Online Diagnostics

Verifying the Online Diagnostics Configuration

Configuration Examples for Online Diagnostics

Additional References

Feature History for Online Diagnostics


Note For complete syntax and usage information for the commands in this chapter, see the
Cisco Nexus 7000 Series NX-OS System Management Command Reference.


Information About Online Diagnostics

Online diagnostics help you verify that hardware and internal data paths are operating as designed so that you can rapidly isolate faults.

This section includes the following topics:

Online Diagnostic Overview

Bootup Diagnostics

Runtime or Health Monitoring Diagnostics

On-Demand Diagnostics

High Availability

Virtualization Support

Online Diagnostic Overview

With online diagnostics, you can test and verify the hardware functionality of the device while the device is connected to a live network.

The online diagnostics contain tests that check different hardware components and verify the data path and control signals. Disruptive online diagnostic tests (such as the disruptive loopback test) and nondisruptive online diagnostic tests (such as the ASIC register check) run during bootup, line module online insertion and removal (OIR), and system reset. The nondisruptive online diagnostic tests run as part of the background health monitoring, and you can run these tests on demand.

Online diagnostics are categorized as bootup, runtime or health-monitoring diagnostics, and on-demand diagnostics. Bootup diagnostics run during bootup, health-monitoring tests run in the background, and on-demand diagnostics run once or at user-designated intervals when the device is connected to a live network.

Bootup Diagnostics

Bootup diagnostics run during bootup and detect faulty hardware before Cisco NX-OS brings a module online. For example, if you insert a faulty module in the device, bootup diagnostics test the module and take it offline before the device uses the module to forward traffic.

Bootup diagnostics also check the connectivity between the supervisor and module hardware and the data and control paths for all the ASICs. Table 13-1 describes the bootup diagnostic tests for a module and a supervisor.

Table 13-1 Bootup Diagnostics  

Diagnostic
Description
Module

EOBCPortLoopback

Disruptive test, not an on-demand test

Ethernet out of band

OBFL

Verifies the integrity of the onboard failure logging (OBFL) flash.

PortLoopback1

Disruptive test, not an on-demand test

Sends and receives data on the same port to verify that the port is operational.

FIPS2

Disruptive test; run only when FIPS is enabled on the system

An internal test that runs during module bootup to validate the security device on the module.

BootupPortLoopback

Disruptive test, not an on-demand test

A PortLoopback test that runs only during module bootup.

Supervisor

USB

Nondisruptive test

Checks the USB controller initialization on a module.

CryptoDevice

Nondisruptive test

Checks the Cisco Trusted Security (CTS) device initialization on a module.

ManagementPortLoopback

Disruptive test, not an on-demand test

Tests loopback on the management port of a module.

EOBCPortLoopback

Disruptive test, not an on-demand test

Ethernet out of band

OBFL

Verifies the integrity of the onboard failure logging (OBFL) flash.

1 The PortLoopback test is supported on all modules except the 48-port 1G copper Ethernet module.

2 F1 Series modules do not support the FIPS test.


Bootup diagnostics log failures to onboard failure logging (OBFL) and syslog and trigger a diagnostic LED indication (on, off, pass, or fail).

You can configure Cisco NX-OS to either bypass the bootup diagnostics or run the complete set of bootup diagnostics. See the "Setting the Bootup Diagnostic Level" section.

Runtime or Health Monitoring Diagnostics

Runtime diagnostics are also called health monitoring (HM) diagnostics. These diagnostics provide information about the health of a live device. They detect runtime hardware errors, memory errors, the degradation of hardware modules over time, software faults, and resource exhaustion.

Health monitoring diagnostics are nondisruptive and run in the background to ensure the health of a device that is processing live network traffic. You can enable or disable health monitoring tests or change their runtime interval. Table 13-2 describes the health monitoring diagnostics and test IDs for a module and a supervisor.

Table 13-2 Health Monitoring Nondisruptive Diagnostics  

Diagnostic
Default Interval
Default Setting
Description
Module

ASICRegisterCheck

1 minute

active

Checks read/write access to scratch registers for the ASICs on a module.

PrimaryBootROM

30 minutes

active

Verifies the integrity of the primary boot device on a module.

SecondaryBootROM

30 minutes

active

Verifies the integrity of the secondary boot device on a module.

PortLoopback1

15 minutes

active

Verifies connectivity through every port that is administratively down on every module in the system.

RewriteEngineLoopback

1 minute

active

Verifies the integrity of the nondisruptive loopback for all ports up to the Rewrite Engine ASIC device.

SnakeLoopback test2

20 minutes

active

Performs a nondisruptive loopback on all ports, even those ports that are not in the shut state. The ports are formed into a snake during module bootup, and the supervisor checks the snake connectivity periodically.

Note This test is deprecated in Cisco NX-OS Release 5.2.

FIPS3

Not applicable

Not applicable

Runs on CTS-enabled ports when the interface is enabled with a no shut command. This internal test validates the security device on the module.

Supervisor

ASICRegisterCheck

20 seconds

active

Checks read/write access to scratch registers for the ASICs on the supervisor.

NVRAM

5 minutes

active

Verifies the sanity of the NVRAM blocks on a supervisor.

RealTimeClock

5 minutes

active

Verifies that the real-time clock on the supervisor is ticking.

PrimaryBootROM

30 minutes

active

Verifies the integrity of the primary boot device on the supervisor.

SecondaryBootROM

30 minutes

active

Verifies the integrity of the secondary boot device on the supervisor.

CompactFlash

30 minutes

active

Verifies access to the internal compact flash devices.

ExternalCompactFlash

30 minutes

active

Verifies access to the external compact flash devices.

PwrMgmtBus

30 seconds

active

Verifies the standby power management control bus.

SpineControlBus4

30 seconds

active

Verifies the availability of the standby spine module control bus.

SystemMgmtBus

30 seconds

active

Verifies the availability of the standby system management bus.

StatusBus

30 seconds

active

Verifies the status transmitted by the status bus for the supervisor, modules, and fabric cards.

StandbyFabricLoopback

30 seconds

active

Verifies the connectivity of the standby supervisor to the crossbars on the spine card.

1 The PortLoopback test is supported on all modules except the 48-port 1G copper Ethernet module.

2 Only F1 Series modules support the SnakeLoopback test.

3 F1 Series modules do not support the FIPS test.

4 Beginning with Cisco NX-OS Release 5.2, the SpineControlBus test is enabled by default on the standby supervisor.


On-Demand Diagnostics

On-demand tests help localize faults and are usually needed in one of the following situations:

To respond to an event that has occurred, such as isolating a fault.

In anticipation of an event that may occur, such as a resource exceeding its utilization limit.

You can run all the health monitoring tests on demand.

You can schedule on-demand diagnostics to run immediately. See the "Starting or Stopping an On-Demand Diagnostic Test" section for more information.

You can also modify the default interval for a health monitoring test. See the "Activating a Diagnostic Test" section for more information.

High Availability

A key part of high availability is detecting hardware failures and taking corrective action while the device runs in a live network. Online diagnostics in high availability detect hardware failures and provide feedback to high availability software components to make switchover decisions.

Cisco NX-OS supports stateless restarts for online diagnostics. After a reboot or supervisor switchover, Cisco NX-OS applies the running configuration.

Virtualization Support

Cisco NX-OS supports online diagnostics in the default virtual device context (VDC). By default, Cisco NX-OS places you in the default VDC. See the Cisco Nexus 7000 Series NX-OS Virtual Device Context Configuration Guide, Release 5.x for more information.

Online diagnostics are virtual routing and forwarding (VRF) aware. You can configure online diagnostics to use a particular VRF to reach the online diagnostics SMTP server.

Licensing Requirements for Online Diagnostics

Product
License Requirement

Cisco NX-OS

Online diagnostics require no license. Any feature not included in a license package is bundled with the Cisco NX-OS system images and is provided at no extra charge to you. For a complete explanation of the Cisco NX-OS licensing scheme, see the Cisco NX-OS Licensing Guide.


Prerequisites for Online Diagnostics

Online diagnostics have the following prerequisite:

If you configure VDCs, install the Advanced Services license and go to the VDC that you want to configure. For more information, see the Cisco Nexus 7000 Series NX-OS Virtual Device Context Configuration Guide, Release 5.x.

Guidelines and Limitations

You cannot run disruptive online diagnostic tests on demand.

The F1 Series modules support only these tests: ASICRegisterCheck, PrimaryBootROM, SecondaryBootROM, EOBCPortLoopback, PortLoopback, BootupPortLoopback, and SnakeLoopback.

Only F1 Series modules support the SnakeLoopback test.

The SnakeLoopback test is deprecated in Cisco NX-OS Release 5.2.

Default Settings

Table 13-3 lists the default settings for online diagnostic parameters.

Table 13-3 Default Online Diagnostic Parameters 

Parameters
Default

Bootup diagnostics level

complete

Nondisruptive tests

active


Configuring Online Diagnostics

This section includes the following topics:

Setting the Bootup Diagnostic Level

Activating a Diagnostic Test

Setting a Diagnostic Test as Inactive

Starting or Stopping an On-Demand Diagnostic Test

Clearing Diagnostic Results

Simulating Diagnostic Results


Note Be aware that the Cisco NX-OS commands for this feature may differ from those commands used in Cisco IOS.


Setting the Bootup Diagnostic Level

You can configure the bootup diagnostics to run the complete set of tests, or you can bypass all bootup diagnostic tests for a faster module bootup time.


Note We recommend that you set the bootup online diagnostics level to complete. We do not recommend bypassing the bootup online diagnostics.


BEFORE YOU BEGIN

Make sure that you are in the correct VDC. To change the VDC, use the switchto vdc command.

SUMMARY STEPS

1. config t

2. diagnostic bootup level {complete | bypass}

3. (Optional) show diagnostic bootup level

4. (Optional) copy running-config startup-config

DETAILED STEPS

 
Command
Purpose

Step 1 

config t

Example:

switch# config t

Enter configuration commands, one per line. End with CNTL/Z.

switch(config)#

Places you in global configuration mode.

Step 2 

diagnostic bootup level {complete | bypass}

Example:

switch(config)# diagnostic bootup level complete

Configures the bootup diagnostic level to trigger diagnostics as follows when the device boots:

complete—Perform all bootup diagnostics. The default is complete.

bypass—Do not perform any bootup diagnostics.

Step 3 

show diagnostic bootup level

Example:

switch(config)# show diagnostic bootup level

(Optional) Displays the bootup diagnostic level (bypass or complete) that is currently in place on the device.

Step 4 

copy running-config startup-config

Example:

switch(config)# copy running-config startup-config

(Optional) Copies the running configuration to the startup configuration.

Activating a Diagnostic Test

You can set a diagnostic test as active and optionally modify the interval (in hours, minutes, and seconds) at which the test runs.

BEFORE YOU BEGIN

Make sure that you are in the correct VDC. To change the VDC, use the switchto vdc command.

SUMMARY STEPS

1. config t

2. (Optional) diagnostic monitor interval module slot test [test-id | name | all] hour hour min minutes second sec

3. diagnostic monitor module slot test [test-id | name | all]

4. (Optional) show diagnostic content module {slot | all}

DETAILED STEPS

 
Command
Purpose

Step 1 

config t

Example:

switch# config t

Enter configuration commands, one per line. End with CNTL/Z.

switch(config)#

Places you in global configuration mode.

Step 2 

diagnostic monitor interval module slot test [test-id | name | all] hour hour min minutes second sec

Example:

switch(config)# diagnostic monitor interval module 6 test 3 hour 1 min 0 sec 0

(Optional) Configures the interval at which the specified test is run. If no interval is set, the test runs at the interval set previously, or the default interval.

The argument ranges are as follows:

slot—The range is from 1 to 10.

test-id—The range is from 1 to 14.

name—Can be any case-sensitive alphanumeric string up to 32 characters.

hour —The range is from 0 to 23 hours.

minute—The range is from 0 to 59 minutes.

second —The range is from 0 to 59 seconds.

Step 3 

diagnostic monitor module slot test [test-id | name | all]

Example:

switch(config)# diagnostic monitor interval module 6 test 3

Activates the specified test.

The argument ranges are as follows:

slot—The range is from 1 to 10.

test-id—The range is from 1 to 14.

name—Can be any case-sensitive alphanumeric string up to 32 characters.

Step 4 

show diagnostic content module {slot | all}

Example:

switch(config)# show diagnostic content module 6

(Optional) Displays information about the diagnostics and their attributes.

Setting a Diagnostic Test as Inactive

You can set a diagnostic test as inactive. Inactive tests keep their current configuration but do not run at at the scheduled interval.

Use the following command in global configuration mode to set a diagnostic test as inactive:

Command
Purpose

no diagnostic monitor module slot test [test-id | name | all]

Example:

switch(config)# no diagnostic monitor interval module 6 test 3

Inactivates the specified test.

The argument ranges are as follows:

slot—The range is from 1 to 10.

test-id—The range is from 1 to 14.

name—Can be any case-sensitive alphanumeric string up to 32 characters.


Starting or Stopping an On-Demand Diagnostic Test

You can start or stop an on-demand diagnostic test. You can optionally modify the number of iterations to repeat this test, and the action to take if the test fails.

We recommend that you only manually start a disruptive diagnostic test during a scheduled network maintenance time.

BEFORE YOU BEGIN

Make sure that you are in the correct VDC. To change the VDC, use the switchto vdc command.

SUMMARY STEPS

1. (Optional) diagnostic ondemand iteration number

2. (Optional) diagnostic ondemand action-on-failure {continue failure-count num-fails | stop}

3. diagnostic start module slot test [test-id | name | all | non-disruptive] [port port-number | all]

4. diagnostic stop module slot test [test-id | name | all]

5. (Optional) show diagnostic status module slot

DETAILED STEPS

 
Command
Purpose

Step 1 

diagnostic ondemand iteration number

Example:

switch# diagnostic ondemand iteration 5

(Optional) Configures the number of times that the on-demand test runs. The range is from 1 to 999. The default is 1.

Step 2 

diagnostic ondemand action-on-failure {continue failure-count num-fails | stop}

Example:

switch# diagnostic ondemand action-on-failure stop

(Optional) Configures the action to take if the on-demand test fails. The num-fails range is from 1 to 999. The default is 1.

Step 3 

diagnostic start module slot test [test-id | name | all | non-disruptive] [port port-number | all]

Example:

switch# diagnostic start module 6 test all

Starts one or more diagnostic tests on a module. The module slot range is from 1 to 10. The test-id range is from 1 to 14. The test name can be any case-sensitive alphanumeric string up to 32 characters. The port range is from 1 to 48.

Step 4 

diagnostic stop module slot test [test-id | name | all]

Example:

switch# diagnostic stop module 6 test all

Stops one or more diagnostic tests on a module. The module slot range is from 1 to 10. The test-id range is from 1 to 14. The test name can be any case-sensitive alphanumeric string up to 32 characters.

Step 5 

show diagnostic status module slot

Example:

switch# show diagnostic status module 6

(Optional) Verifies that the diagnostic has been scheduled.

Clearing Diagnostic Results

You can clear diagnostic test results.

Use the following command in any mode to clear the diagnostic test results:

Command
Purpose

diagnostic clear result module [slot | all] test {test-id | all}

Example:

switch# diagnostic clear result module 2 test all

Clears the test result for the specified test.

The argument ranges are as follows:

slot—The range is from 1 to 10.

test-id—The range is from 1 to 14.


Simulating Diagnostic Results

You can simulate a diagnostic test result.

Use the following command in any mode to simulate a diagnostic test result:

Command
Purpose

diagnostic test simulation module slot test test-id {fail | random-fail | success} [port number | all]

Example:

switch# diagnostic test simulation module 2 test 2 fail

Simulates a test result. The test-id range is from 1 to 14. The port range is from 1 to 48.


Use the following command in any mode to clear the simulated diagnostic test result:

Command
Purpose

diagnostic test simulation module slot test test-id clear

Example:

switch# diagnostic test simulation module 2 test 2 clear

Clears the simulated test result. The test-id range is from 1 to 14.


Verifying the Online Diagnostics Configuration

To display online diagnostics configuration information, perform one of the following tasks:

Command
Purpose

show diagnostic bootup level

Displays information about bootup diagnostics.

show diagnostic content module {slot | all}

Displays information about diagnostic test content for a module.

show diagnostic description module slot test [test-name | all]

Displays the diagnostic description.

show diagnostic events [error | info]

Displays diagnostic events by error and information event type.

show diagnostic ondemand setting

Displays information about on-demand diagnostics.

show diagnostic result module slot [test [test-name | all]] [detail]

Displays information about the results of a diagnostic.

show diagnostic simulation module slot

Displays information about a simulated diagnostic.

show diagnostic status module slot

Displays the test status for all tests on a module.

show hardware capacity [eobc | fabric-utilization | forwarding | interface | module | power]

Displays information about the hardware capabilities and current hardware utilization by the system.

show module

Displays module information including the online diagnostic test status.


Configuration Examples for Online Diagnostics

This example shows how to start all on-demand tests on module 6:

diagnostic start module 6 test all

This example shows how to activate test 2 and set the test interval on module 6:

conf t

 diagnostic monitor module 6 test 2

 diagnostic monitor interval module 6 test 2 hour 3 min 30 sec 0

Additional References

For additional information related to implementing online diagnostics, see the following sections:

Related Documents

Standards

Related Documents

Related Topic
Document Title

Online diagnostics CLI commands

Cisco Nexus 7000 Series NX-OS System Management Command Reference

VDCs and VRFs

Cisco Nexus 7000 Series NX-OS Virtual Device Context Configuration Guide, Release 5.x


Standards

Standards
Title

No new or modified standards are supported by this feature, and support for existing standards has not been modified by this feature.


Feature History for Online Diagnostics

Table 13-4 lists the release history for this feature.

Table 13-4 Feature History for Online Diagnostics

Feature Name
Releases
Feature Information

Online diagnostics (GOLD)

5.2(1)

Enabled the SpineControlBus test on the standby supervisor.

Online diagnostics (GOLD)

5.2(1)

Deprecated the SnakeLoopback test on F1 Series modules.

Online diagnostics (GOLD)

5.1(2)

Added support for the SnakeLoopback test on F1 Series modules.

Online diagnostics (GOLD)

5.1(1)

Added support for the FIPS and BootupPortLoopback tests.

Online diagnostics (GOLD)

5.0(2)

No change from Release 4.2.

Online diagnostics (GOLD)

4.2(1)

Added support for the PortLoopback, StatusBus, and StandbyFabricLoopback tests.

Online diagnostics (GOLD)

4.0(1)