Field Notice: *Expired* FN - 27595 - WS-SUP720 May Experience NVRAM Corruption


Revised February 23, 2006

February 20, 2004


NOTICE:


THIS FIELD NOTICE HAS BEEN ARCHIVED AND IS NO LONGER MAINTAINED OR UPDATED BY CISCO.

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE, WARRANTY OR SUPPORT. USE OF THE INFORMATION ON THIS FIELD NOTICE OR MATERIALS LINKED FROM THIS FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.

Products Affected

Product Top Assembly Printed Circuit Assembly Comments HW Rev.
Part Number Rev. Part Number Rev.
WS-SUP720 (=)   68-1916-12 and below   A0-B0   73-7404-10 and below   A0   PCA 73-9269-xx is not affected. 1.0 -1.4  

Serial Numbers

Random #
SAD0739xxxx and below are affected. 

Problem Description

The WS-SUP720 may experience NVRAM corruption due to a faulty crystal oscillator.  

Background

The Supervisor may experience NVRAM corruption which results in the inability to boot the operating system. Internal testing has verified that this problem is due to a faulty crystal on the hardware versions specified in the Products Affected section above.  

Problem Symptoms

NVRAM Corruption:

SP Console:
System Bootstrap, Version 7.7(1)
Copyright (c) 1994-2003 by cisco Systems, Inc.

Testing lower main memory - data equals address
Testing lower main memory - checkerboard
Testing lower main memory - inverse checkerboard
Clearing lower 16K memory for cache initialization
Clearing bss
Reading monitor variables from NVRAM
Warning: Rommon NVRAM area is corrupted. Initialize the area to default values
environment checksum in NVRAM failed
environment checksum in NVRAM failed

Enabling interrupts
Initializing TLB
Initializing cache
Initializing required TLB entries
Initializing main memory
Sizing NVRAMWarning: NVRAM size is 0

Initializing PCMCIA controller
Exiting init
Cat6k-Sup720/SP processor with 524288 Kbytes of main memory


*** TLB (Load/Fetch) Exception ***
Access address = 0xffffffff
PC = 0xbfc29f44, Cause = 0x8, Status Reg = 0x30409003

System Bootstrap, Version 7.7(1)
Copyright (c) 1994-2003 by cisco Systems, Inc.

Testing lower main memory - data equals address
Testing lower main memory - checkerboard
Testing lower main memory - inverse checkerboard
Clearing lower 16K memory for cache initialization
Clearing bss
Reading monitor variables from NVRAM
Warning: Rommon NVRAM area is corrupted. Initialize the area to default values
environment checksum in NVRAM failed

Enabling interrupts
Initializing TLB
Initializing cache
Initializing required TLB entries
Initializing main memory
*** Reserved General Exception ***
PC = 0x80006edc, Cause = 0x80000060, Status Reg = 0x30619001
ROM Monitor Can Not Recover From Exception
A Board Reset Is Issued

Sizing NVRAMWarning: NVRAM size is 0

Initializing PCMCIA controller
Exiting init
Cat6k-Sup720/SP processor with 524288 Kbytes of main memory


*** Unknown External Interrupt ***
Stacked Cause = 0x0, Stacked Status Reg = 0x30609001
Current Cause IP[15..0] = 0x0, Current SREG IM[7..0] = 0x90
System Bootstrap, Version 7.7(1)
Copyright (c) 1994-2003 by cisco Systems, Inc.

Testing lower main memory - data equals address
Testing lower main memory - checkerboard
Testing lower main memory - inverse checkerboard
Clearing lower 16K memory for cache initialization
Clearing bss
Reading monitor variables from NVRAM
Warning: Rommon NVRAM area is corrupted. Initialize the area to default values
environment checksum in NVRAM failed

Enabling interrupts
Initializing TLB
Initializing cache
Initializing required TLB entries
Initializing main memory
*** Reserved General Exception ***
PC = 0x80006edc, Cause = 0x80000060, Status Reg = 0x30619001
ROM Monitor Can Not Recover From Exception
A Board Reset Is Issued

Sizing NVRAMWarning: NVRAM size is 0

Initializing PCMCIA controller
Exiting init
Cat6k-Sup720/SP processor with 524288 Kbytes of main memory


*** Reserved General Exception ***
PC = 0xbfc29f48, Cause = 0x60, Status Reg = 0x30609001

System Bootstrap, Version 7.7(1)
Copyright (c) 1994-2003 by cisco Systems, Inc.

Testing lower main memory - data equals address
Testing lower main memory - checkerboard
Testing lower main memory - inverse checkerboard
Clearing lower 16K memory for cache initialization
Clearing bss
Reading monitor variables from NVRAM
Warning: Rommon NVRAM area is corrupted. Initialize the area to default values
environment checksum in NVRAM failed

Enabling interrupts
Initializing TLB
Initializing cache
Initializing required TLB entries
Initializing main memory
*** Reserved General Exception ***
PC = 0x80006edc, Cause = 0x80000060, Status Reg = 0x30619001
ROM Monitor Can Not Recover From Exception
A Board Reset Is Issued

Sizing NVRAMWarning: NVRAM size is 0

Initializing PCMCIA controller
Exiting init
Cat6k-Sup720/SP processor with 524288 Kbytes of main memory


*** Unknown External Interrupt ***
Stacked Cause = 0x0, Stacked Status Reg = 0x30609001
Current Cause IP[15..0] = 0x0, Current SREG IM[7..0] = 0x90
System Bootstrap, Version 7.7(1)
Copyright (c) 1994-2003 by cisco Systems, Inc.

Testing lower main memory - data equals address
Testing lower main memory - checkerboard
Testing lower main memory - inverse checkerboard
Clearing lower 16K memory for cache initialization
Clearing bss
Reading monitor variables from NVRAM
Warning: Rommon NVRAM ar?


RP Console
rommon 2 > i

System Bootstrap, Version 12.2(14r)S1, RELEASE SOFTWARE (fc1)
TAC Support: http://www.cisco.com/tac
Copyright (c) 2003 by cisco Systems, Inc.

Warning: Rommon NVRAM area is corrupted. Initialize the area to default values
environment write to NVRAM failed
Write to NVRAM addr failed
environment write to NVRAM failed
Cat6k-Sup720/RP platform with 524288 Kbytes of main memory

Download Start

Workaround/Solution

The affected crystal has been replaced on the supervisor. HW versions 1.5 and above and serial numbers SAD0740xxxx and above of any MSFC3 Daughter Boards will NOT exhibit this problem.


Confirm the Supervisor is within the serial number range and hardware version specified in the Products Affected section above. If the product is within the serial number range but at a higher HW version than specified above, it is NOT affected.
 

DDTS

DDTS Description
CSCec34824(registered customers only) C2:NVRAM corruption/exception at rommon

How To Identify Hardware Levels

To identify the hardware version and serial number of your Supervisor, use the following commands:

CatOS:
Console> sh mod
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- ---
--------
5 5 2 1000BaseX Supervisor WS-SUP720-BASE yes ok
15 5 1 Multilayer Switch Feature WS-SUP720 no ok
6 6 2 1000BaseX Supervisor WS-SUP720-BASE yes standby

16 6 1 Multilayer Switch Feature WS-SUP720 no standby


Mod Module-Name Serial-Num
--- -------------------- -----------
5 SAD01112222
15 SAD01234567 <---- SERIAL NUMBER
6 SAD02221111
16 SAD07654321 <---- SERIAL NUMBER


Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ----------
-----------------
5 00-05-9a-3b-da-ce to 00-05-9a-3b-da-cf 1.5 7.7(1)
8.2(0.80)DEL
00-05-9a-3b-da-cc to 00-05-9a-3b-da-cf
00-e0-40-04-ff-00 to 00-e0-40-05-02-ff
15 00-e0-40-05-02-fc to 00-e0-40-05-02-fd 1.2 12.2(14)SX 12.2(14)SX2 <---- HW VERSION

6 00-40-0b-f0-1d-e6 to 00-40-0b-f0-1d-e7 1.5 7.7(1)
8.2(0.80)DEL
00-40-0b-f0-1d-e4 to 00-40-0b-f0-1d-e7
16 00-e0-40-05-02-fc to 00-e0-40-05-02-fd 1.2 12.2(14)SX 12.2(14)SX2 <---- HW VERSION


Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
Sub-Sw
--- ----------------------- ------------------- ----------- ------
------
5 L3 Switching Engine III WS-F6K-PFC3A SAD071700AR 0.401
6 L3 Switching Engine III WS-F6K-PFC3A SAD070502G4 0.401

Console>

IOS:
Console#sh mod
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
5 2 Supervisor Engine 720 (Active) WS-SUP720-BASE SAD072403FP

Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
5 000c.ce64.0f64 to 000c.ce64.0f67 2.1 8.1(3-Eng) 12.2(17b)SXA Ok

Mod Sub-Module Model Serial Hw Status
--- --------------------------- ------------------ ------------ ------- -------
5 Policy Feature Card 3 WS-F6K-PFC3A SAD072402F9 1.1 Ok
5 MSFC3 Daughterboard WS-SUP720 SAD01234567 1.2 Ok <---- SERIAL NUMBER AND HW VERSION

Mod Online Diag Status
--- -------------------
5 Pass
Router
Router#sh idprom rp 5
IDPROM for RP #5
(FRU is 'MSFC3 Daughterboard')
OEM String = 'Cisco Systems'
Product Number = 'WS-SUP720'
Serial Number = 'SAD01234567' <---- SERIAL NUMBER
Manufacturing Assembly Number = '73-7404-08'
Manufacturing Assembly Revision = 'E0'
Hardware Revision = 1.2 <---- HW VERSION
Current supplied (+) or consumed (-) = -0.75A

Revision History

Revision Date Comment
1.7 23-FEB-2006 Remove Upgrade Program and Expire
1.6 26-OCT-2005 Maintenance update
1.5 08-JUN-2004 Maintenance update
1.4 02-JUN-2004 Maintenance update
1.3 26-APR-2004 Maintenance update
1.2 09-APR-2004 Maintenance update
1.1 26-FEB-2004 Maintenance update
1.0 20-FEB-2004 Initial Public Release

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods: