Cisco MDS 9100 Series Hardware Installation Guide
Technical Specifications

Table Of Contents

Technical Specifications

Switch Specifications

Power Specifications

General Power Supply Specifications

Power Supply Requirements and Heat Dissipation Specifications

Connection Guidelines for AC-Powered Systems

SFP Transceiver Specifications

Cisco Fibre Channel SFP Transceivers

General Specifications for Cisco Fibre Channel SFP Transceivers

Environmental and Electrical Specifications for Cisco Fibre Channel SFP Transceivers

Cisco Gigabit Ethernet/Fibre Channel Transceivers

General Specifications for Cisco GE/FC SFP Transceivers

Environmental and Electrical Specifications for Cisco GE/FC SFP Transceivers

Cisco CWDM SFP Transceivers

General Specifications for Cisco CWDM SFP Transceivers

Environmental and Electrical Specifications for Cisco CWDM SFP Transceivers

Optical Specifications for Cisco CWDM SFP Transceivers

X2 Transceiver Specifications


Technical Specifications


This appendix includes the following technical specifications for the Cisco MDS 9100 Series Fixed Configuration Fabric Switch:

Switch Specifications

Power Specifications

SFP Transceiver Specifications

X2 Transceiver Specifications

Switch Specifications

Table B-1 lists the environmental specifications for the Cisco MDS 9100 Series.

Table B-1 Environmental Specifications for the Cisco MDS 9100 Series

Description
Specification

Temperature, ambient operating

32 to 104°F (0 to 40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10 to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5 to 95%

Altitude, operating

-197 to 6500 ft (-60 to 2000 m)

Noise levels

60 dB


Table B-2 lists the physical specifications for the Cisco MDS 9100 Series.

Table B-2 Cisco MDS 9100 Series Switch Specifications 

Description
Specification

Cisco MDS 9134 Switch Dimensions

Width = 17.16 in. (43.59 cm)

Height = 1.72 in. (4.47 cm)

Depth = 18.89 in. (47.98 cm)

Cisco MDS 9124 Switch Dimensions

Width = 17.16 in. (44.45 cm)

Height = 1.72 in. (4.45 cm)

Depth = 16 in. (40.64 cm)

Cisco MDS 9140 and MDS 9120 Switch Dimensions

Width = 17.2 in. (43.69 cm)

Height = 1.75 in. (4.45 cm)

Depth = 23.1 in. (58.67 cm)

Depth with cable guide = 28.1 in. (71.37 cm)

Rack Unit (RU)

Chassis requires 1 RU (1.75 in. or 4.45 cm)

Weight

25 lb (Cisco MDS 9140 Switch and Cisco MDS 9120 Switch chassis with two fan modules and two power supplies installed)

20 lb Cisco MDS 9134 Switch with two power supplies installed

16.5 lb (Cisco MDS 9124 Switch with a single power supply installed)

18.5 lb (Cisco MDS 9124 Switch with two power supplies installed)

Power Supply (fixed)

300-W AC for each power supply

Power Supply (optional redundant power supply)

300-W AC for each power supply

Part Number: DS-CAC-300W (Cisco MDS 9140 Switch and Cisco MDS 9120 Switch)

Part Number: DS-C49-300AC (Cisco MDS 9124 Switch)

Airflow

Front to back.

250 lfm1 or 42 cfm2 through the system. A minimum clearance of 2.5 in. (6.4 cm) is required between the chassis air vents and any walls.

1 lfm = linear feet per minute

2 cfm = cubic feet per minute


Power Specifications

This section includes the following information:

General Power Supply Specifications

Power Supply Requirements and Heat Dissipation Specifications

Connection Guidelines for AC-Powered Systems

General Power Supply Specifications

Table B-3 lists the specifications for the Cisco MDS 9100 Series AC input power supply.

Table B-3 Cisco MDS 9100 Series AC Input Power Supply Specifications

AC-Input Power Supply
Specification

AC-input voltage

Minimum = 85 VAC

Nominal = 100 to 240 VAC

Maximum = 264 VAC

AC-input current rating (maximum)

4.7 A at 85 VAC
3.6 A at 110 VAC
1.8 A at 220 VAC

Note For plug current rating, see the "Jumper Power Cord" section on page C-5.

AC-input frequency

Minimum = 47 Hz

Nominal = 50 to 60 Hz

Maximum = 63 Hz

Power supply output capacity

300 W

Power supply output voltage

12 V +/- 6% up to 25 A

Output holdup time

20 ms when input > 100 VAC


Power Supply Requirements and Heat Dissipation Specifications

Table B-4 provides a sample calculation of power and heat dissipation for the Cisco MDS 9100 Series.

Table B-4 Power and Heat Dissipation 

Model Number/
AC-Input Power (watts)
Heat Diss. (BTU/hr)
Input Current
85 VAC (amps)
110 VAC (amps)
220 VAC (amps)

Cisco MDS 9134 Switch (with fan modules)

96 maximum

330

1.41

1.10

.55

Cisco MDS 9124 Switch (with fan modules)

96 maximum

330

1.41

1.10

.55

Cisco MDS 9140 Switch (with fan modules)

204 maximum

870

3.0

2.32

1.16

Cisco MDS 9120 Switch (with fan modules)

180 maximum

752

2.65

2.05

1.02



Tip To prevent a loss of input power, ensure the total maximum load on each circuit supplying the power supply is within the current ratings of the wiring and breakers.


Connection Guidelines for AC-Powered Systems

For connecting the Cisco MDS 9100 Series switch AC power supplies to the site power source, follow these basic guidelines

Each power supply should have its own dedicated branch circuit.

For international, circuits should be sized according to local and national codes.

The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment.

SFP Transceiver Specifications

The Cisco MDS 9100 Series is compatible with SFP transceivers and cables that have LC connectors. Each transceiver must match the transceiver on the other end of the cable in terms of wavelength, and the cable must not exceed the stipulated cable length for reliable communications.

Cisco SFP transceivers provide the uplink interfaces, laser transmit (TX), and laser receive (RX), and they support 850 to 1610 nm nominal wavelengths, depending upon the transceiver.

Use only Cisco SFP transceivers on the Cisco MDS 9100 Series. Each Cisco SFP transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch. For the list of supported SFP transceivers, see the release notes.

This section provides the following information:

Cisco Fibre Channel SFP Transceivers

Cisco Gigabit Ethernet/Fibre Channel Transceivers

Cisco CWDM SFP Transceivers

For information about safety, regulatory, and standards compliance, see the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

Cisco Fibre Channel SFP Transceivers

Table B-5 lists the Fibre Channel SFP transceivers available through Cisco Systems for the Cisco MDS 9124 Switch.

Table B-5 Cisco Fibre Channel SFP Transceivers for the Cisco MDS 9124 Switch

Part Number
Description
Type

DS-SFP-FC4G-SW

4-Gbps/2-Gbps/1-Gbps Fibre Channel-short wavelength SFP

Short wavelength

DS-SFP-FC4G-MR

4-Gbps/2-Gbps/1-Gbps Fibre Channel-long wavelength SFP

Long wavelength

DS-SFP-FC4G-LW

4-Gbps/2-Gbps/1-Gbps Fibre Channel-long wavelength SFP

Long wavelength


Table B-6 lists the Fibre Channel SFP transceivers available through Cisco Systems for the Cisco MDS 9140 Switch and the Cisco MDS 9120 Switch.

Table B-6 Cisco Fibre Channel SFP Transceivers for the Cisco MDS 9140 Switch and the Cisco MDS 9120 Switch

Part Number
Description
Type

DS-SFP-FC2G-SW

2-Gbps/1-Gbps Fibre Channel-short wavelength SFP

Short wavelength

DS-SFP-FC2G-LW

2-Gbps/1-Gbps Fibre Channel-long wavelength SFP

Long wavelength


General Specifications for Cisco Fibre Channel SFP Transceivers

Table B-7 lists general specifications for Cisco Fibre Channel SFP transceivers at 4 Gbps.


Note The cable distances provided are for 4 Gbps.


Table B-7 General Specifications for Cisco Fibre Channel SFP Transceivers at 4 Gbps

Description
Short wavelength
Long wavelength

Connector type

LC

LC

Wavelength

850 nm

1310 nm

Fiber type

MMF

SMF

Core size

50 microns

62.5 microns

9/125 microns

Cable distance1

328.08 yd (300 m)

164.04 yd (150 m)

6.2 miles (10 km)

Transmit power

-9 to -2.5 dBm

-8.4 to -2 dBm

1 Approximate; actual distance may vary depending on fiber quality and other factors.


Table B-8 lists general specifications for Cisco Fibre Channel SFP transceivers at 2 Gbps.


Note The cable distances provided are for 2 Gbps.


Table B-8 General Specifications for Cisco Fibre Channel SFP Transceivers

Description
Short wavelength
Long wavelength

Connector type

LC

LC

Wavelength

850 nm

1310 nm

Fiber type

MMF

SMF

Core size

50 microns

62.5 microns

9/125 microns

Cable distance1

300 m

150 m

10 km

Transmit power

-10 to -1.5 dBm

-9.5 to -3 dBm

1 Approximate; actual distance may vary depending on fiber quality and other factors.


Environmental and Electrical Specifications for Cisco Fibre Channel SFP Transceivers

Table B-9 provides the maximum environmental and electrical ratings for Cisco Fibre Channel SFP transceivers.

Table B-9 Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP Transceivers

Parameter
Symbol
Min.
Max.
Unit
Storage temperature1

TS

-40

85

°C

Case temperature1, 2

TC

0

70

°C

Relative humidity1,

RH

5

95

%

Module supply voltage1,

VCCT,R

3.1

3.5

V

1 Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period of time. See Reliability Data Sheet for specific reliability performance.

2 Functional performance is not intended, device reliability is not implied, and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions.


Cisco Gigabit Ethernet/Fibre Channel Transceivers

Table B-10 lists the combination Gigabit Ethernet/Fibre Channel (GE/FC) SFP transceivers available through Cisco Systems for the Cisco MDS 9140 Switch and the Cisco MDS 9120 Switch.

Table B-10 Cisco Gigabit Ethernet / Fibre Channel SFP Transceivers

Part Number
Description
Type

DS-SFP-FCGE-SW

1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-short wavelength SFP

Short wavelength

DS-SFP-FCGE-LW

1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel-long wavelength SFP

Long wavelength

DS-SFP-GE-T

1-Gbps Ethernet SFP

 

General Specifications for Cisco GE/FC SFP Transceivers

Table B-11 lists general specifications for Cisco combination Gigabit Ethernet/Fibre Channel SFP transceivers.


Note The cable distances provided are for 2-Gbps.


Table B-11 General Specifications for Cisco Gigabit Ethernet/Fibre Channel SFP Transceivers  

Description
Short wavelength
Long wavelength

Connector type

LC

LC

Wavelength

850 nm

1310 nm

Fiber type

MMF

SMF

Core size

50 microns

62.5 microns

9/125 microns

Cable distance1

300 m

150 m

10 km

Transmit power

-1.5 to -9.5 dBm

-3 to -9.5 dBm

1 Approximate; actual distance may vary depending on fiber quality and other factors.


Environmental and Electrical Specifications for Cisco GE/FC SFP Transceivers

Table B-12 provides the maximum environmental and electrical ratings for Cisco GE/FC SFP transceivers.

Table B-12 Maximum Environmental and Electrical Ratings for Cisco GE/FC SFP Transceivers

Parameter
Symbol
Min.
Max.
Unit

Storage temperature1

TS

-40

100

°C

Case temperature1, 2

TC

0

85

°C

Relative humidity1

RH

5

95

%

Module supply voltage1

VCCT,R

3.1

3.5

V

1 Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period of time. See Reliability Data Sheet for specific reliability performance.

2 Functional performance is not intended, device reliability is not implied, and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions.


Cisco CWDM SFP Transceivers

Table B-13 lists the CWDM SFP transceivers available through Cisco Systems. These SFP transceivers are supported by the Cisco MDS 9140 and Cisco MDS 9120 switch.

Table B-13 Cisco CWDM SFP Transceivers

Part Number
Description

DS-CWDM-xxxx

Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps Fibre Channel SFP LC interface xxxx where xxxx = 1470, 1490, 1510, 1530, 1550, 1570, 1590, or 1610 nm.

DS-CWDM-MUX-4

Add/drop multiplexer for four CWDM wavelengths.

DS-CWDM-MUX-8

Add/drop multiplexer for eight CWDM wavelengths.

DS-CWDMCHASSIS

Two slot chassis for CWDM add/drop multiplexers.


Table B-14 Cisco CWDM SFP Transceivers Color Codes 

Description
Color

Cisco CWDM SFP 1470 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Gray

Cisco CWDM SFP 1490 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Violet

Cisco CWDM SFP 1510 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Blue

Cisco CWDM SFP 1530 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Green

Cisco CWDM SFP 1550 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Yellow

Cisco CWDM SFP 1570 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Orange

Cisco CWDM SFP 1590 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Red

Cisco CWDM SFP 1610 nm; Gigabit Ethernet and 1-Gbps/2-Gbps/4-Gbps FC

Brown


General Specifications for Cisco CWDM SFP Transceivers

Table B-15 lists general specifications for Cisco CWDM SFP transceivers.

Table B-15 General Specifications for Cisco CWDM SFP Transceivers

Description
Specification

Connector type

LC

Wavelength

1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 nm

Fiber type

SMF

Core size

9/125 microns

Cable distance1

100 km

Transmit power

0 to 5 dBm

Receive sensitivity

-28 to -7 dBm

1 Approximate; actual distance may vary depending on fiber quality and other factors.


Environmental and Electrical Specifications for Cisco CWDM SFP Transceivers

Table B-16 provides the environmental specifications for CWDM SFP transceivers.

Table B-16 Environmental Specifications for Cisco CWDM SFP Transceivers  

Description
Specification

Temperature, ambient operating

32 to 122°F (0 and 50°C)

Temperature, ambient nonoperating and storage

-40 to 185°F (-40 to 85°C)


Table B-17 provides the electrical specifications for CWDM SFP transceivers.

Table B-17 Electrical Specifications for Cisco CWDM SFP Transceivers 

Parameter
Symbol
Minimum
Typical
Maximum
Units

Supply Current

|s

 

220

300

mA

Surge Current

|surge

   

+30

mA

Input voltage

Vmax

3.1

3.3

3.6

V


Optical Specifications for Cisco CWDM SFP Transceivers

Table B-18 provides the optical specifications for CWDM SFP transceivers. CWDM SFP transceivers have an optical link budget of 28 decibels (db).


Note The parameters are specified over temperature and at end of life unless otherwise noted.



Note When shorter distances of single-mode fiber are used, it might be necessary to insert an inline optical attenuator in the link to avoid overloading the receiver.

Table B-18 Optical Specifications for Cisco CWDM SFP Transceivers 

Parameter
Symbol
Min.
Typical
Max.
Units
Notes

Transmitter central wavelength

lc

(x-4)

(x+1)

(x+7)

nm

Available center wavelengths:
1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 nm

Wavelength temperature dependence

   

0.08

0.1

nm/°C

 

Side-mode suppression ratio

SMSR

30

   

dB

 

Transmitter optical output power

Pout

0.0

 

5.0

dBm

Average power coupled into single-mode fiber

Receiver optical input power (BER <10-12 with PRBS 2-7-1)

Pin

-28.0

 

-7.0

dBm

@ 2.12 Gbps, 140°F (60°C) case temp.

Receiver optical input wavelength

lin

1450

 

1620

Nm

 

Transmitter extinction ratio

OMI

9

   

dB

 

Dispersion penalty at 60 km

     

2

dB

 

Dispersion penalty at 100 km

     

2

db

@ 1.25 Gbps

3

dB

@ 2.12 Gbps



X2 Transceiver Specifications

The Cisco MDS 9134 Switch is compatible with X2 transceivers and cables that have SC connectors. Each transceiver must match the transceiver on the other end of the cable in terms of wavelength, and the cable must not exceed the stipulated cable length for reliable communications.

Use only Cisco X2 transceivers with the Cisco MDS 9134 Switch. Each Cisco X2 transceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch.

For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

Table B-19 lists the 10-Gigabit/Ethernet X2 transceiver module available through Cisco.

Table B-19 10-Gigabit X2 Transceiver Modules

X2 Transceiver Module Product Number
Description

DS-X2-FC10G-SR

Cisco 10GFC-SR X2 transceiver module for MMF, dual SC connector

DS-X2-FC10G-LR

Cisco 10GFC-LR X2 transceiver module for SMF, dual SC connector

DS-X2-FC10G-ER

Cisco 10GFC-ER X2 transceiver module for SMF, dual SC connector

DS-X2-FC10G-CX4

Cisco 10GFC-CX4 X2 copper transceiver module, CX4 connector


Table B-20 lists the port cabling specifications for the 10-Gigabit X2 transceiver modules. Table B-21 lists the X2 transceiver optical transmit and receive specifications.

Table B-20 X2 Transceiver Port Cabling Specifications 

X2 Product Number
Wavelength (nm)
Cable Type
Core Size (microns)
Modal Bandwidth (MHz/km)
Maximum Cabling Distance

DS-X2-FC10G-SR

850

MMF

62.5

62.5

50.0

50.0

50.0

160

200

400

500

2000

26 m (85.3 ft.)

33 m (108.3 ft.)

66 m (216.5 ft.)

82 m (269 ft.)

300 m (984.3 ft.)

DS-X2-FC10G-LR

1310

SMF

G.652 fiber

10 km (6.21 miles)

DS-X2-FC10G-ER

1550

SMF

G.652 fiber

40 km (24.8 miles)

DS-X2-FC10G-CX4

Copper

CX4

Copper

15 m (49.2 ft.)


Table B-21 X2 Transceiver Optical Transmit and Receive Specifications

X2 Product Number
Transceiver Type
Transmit Power (dBm)
Receive Power (dBm)
Transmit and Receive Wavelength (nm)

DS-X2-FC10G-SR

10GFC-SR,
850-nm MMF

— (Max)
-7.3 (Min)

-1.0 (Max)
-9.9 (Min)

840 to 860

DS-X2-FC10G-LR

10GFC-LR,
1310-nm SMF

0.5 (Max)
-8.2 (Min)

0.5 (Max)
-14.4 (Min)

1260 to 1355

DS-X2-FC10G-ER

10GFC-ER,
1550-nm SMF

4.0 (Max)
-4.7 (Min)

-1.0 (Max)
-15.8 (Min)

1550

DS-X2-FC10G-CX4

10GFC-CX4,
Copper