Cisco ONS 15310-CL Reference Manual, Release 6.0
Appendix A, Specifications

Table Of Contents

Specifications

A.1  Shelf Specifications

A.1.1  Bandwidth

A.1.2  Expansion Slot

A.1.3  Internal Cards

A.1.4  15310-CL-CTX

A.1.5  Configurations

A.1.6  Cisco Transport Controller

A.1.7  TL1 Craft Interface

A.1.8  LEDs

A.1.9  Alarm Interface

A.1.10  DS1 Interface

A.1.11  DS3/EC1 Interface

A.1.12  Nonvolatile Memory

A.1.13  BITS Interface

A.1.14  RJ-45 Connector Pin Assignments

A.1.15  Pushbuttons

A.1.16  System Timing

A.1.17  Power Specifications

A.1.18  Environmental Specifications

A.1.19  Shelf Dimensions

A.2  Card Specifications

A.2.1  CE-100T-8 and ML-100T-8 Cards

A.2.2  Filler Card

A.3  SFP Specifications


Specifications



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This appendix contains shelf, card, and small-form factor pluggable (SFP) specifications for the Cisco ONS 15310-CL.

A.1  Shelf Specifications

This section includes hardware and software specifications.

A.1.1  Bandwidth

Total bandwidth: 2.054 Gbps

Optical: 1.24 Gbps (2 x OC-12)

Electrical: 188 Mbps

Expansion: 622 Mbps (OC-12)

A.1.2  Expansion Slot

Total card slots: 1 expansion slot for CE-100T-8 and ML-100T-8 cards. A blank card (15310-EXP-FILLER) can also be plugged into the expansion slot.

A.1.3  Internal Cards

Common Control, Timing, Cross-Connect Customer-Located (15310-CL-CTX)

Interconnect card

Connector expansion card

A.1.4  15310-CL-CTX

Optical Ports

Two user upgradeable and hot swappable SFPs with SONET interface support

Support for multirate SFPs (155.520 Mbps and 622.080 Mbps)

Support for operating the two optical facilities at different line rates in unprotected facility mode (non 1+1 Automatic Protection Switching [APS] operation)

T1 Ports

Supports GR499-compliant 1.544 Mbps (T1) interface

Performance monitoring is provided via the interface to allow validation of signal quality.

Any outgoing T1 signal can be retimed to eliminate accumulated jitter and wander at the point of egress from a synchronous network.

Any incoming T1 signal from the transport element can also be used as a timing source.

T3/EC1 Ports

Supports GR499-compliant 44.736 Mbps (DS3) interfaces or EC1.

Performance monitoring is provided via the interface to allow validation of signal quality. Each port can be provisioned in any combination of T3 or EC1.

BITS

Supports one BITS input and one BITS output

The BITS I/O ports support a 100-ohm termination for external 1.544 Mbps DS1 timing signals.

Alarm

The alarm system provides three alarm inputs and two contacts for alarm outputs.

LAN

Supports a 10/100 Mbps Ethernet interface for CTC/TL1 provisioning.

For node access in secure mode, SSL (for TL1) and HTTPS (for CTC) security protocols are supported.

Craft Interface

An RS-232 Craft interface is provided and is used for TL1 provisioning.

The Craft interface is set to 9600 baud, no parity, and 1 stop bit by default.

64 kbps User Data Channel (UDC) Digital Interface

The 64 kbps Digital Interface provides a digital input and output.

Any F1 byte that is accessible on the system is interfaced at the UDC connector.

The UDC provides a simplex interface. Protection for UDC overhead channel(s) follows interface line protection for traffic.

The UDC can be enabled or disabled through the management interfaces. The default state is disabled.

The UDC supports a 64 kbps serial interface adaptation function to overhead byte F1.

The physical interface is defined in G.703 as a 120-ohm, twisted pair connection. The jitter specification is defined in G.823.

The UDC supports a serial port interface adaptation function to overhead bytes F1. This is an RS-232 interface capable of 9.6, 19.2, 38.4, and 56 kbps operation. The rate is selectable through the management interface. The default is 56 kbps with no parity and 1 stop bit.

A.1.5  Configurations

Two-fiber path protection

1+1 protection

Path protected mesh network (PPMN)

Add-drop multiplexer

Point-to-point terminal mode

A.1.6  Cisco Transport Controller

10/100 Base-T

15310-CL-CTX access: RJ-45 connector

A.1.7  TL1 Craft Interface

Speed: 9600 baud, no parity, 1 stop bit

15310-CL-CTX: RS-232 with RJ-45 type connector

A.1.8  LEDs

Table A-1 describes the possible LED colors and their significance.

Table A-1 LED Description

LED
Color

FAIL

Red for system failure or during initialization

ALARM

Red (Major and Critical)

Amber (Minor)

PWR

Green (AC source present or both DC sources present)

Amber (one DC source present)

SYNC

Green (primary and secondary reference sync)

Amber (only one reference)

Red (loss of both references)


A.1.9  Alarm Interface

Visual: Critical (red LED), Major (red LED), Minor (amber LED)

Three alarm inputs and two alarm contacts, all on the same RJ-45 connector (ALARM port)

A.1.10  DS1 Interface

21 DS-1 (1.544 Mbps) ports

Connector: LFH96 (100-ohm balanced)

Any two ports can be used as primary and secondary timing sources

A DS01 output can be retimed to system clock on a per-port basis

The DS-1 connector pin assignments are shown in Table A-2.

Table A-2 DS-1 Connector Pin Assignments 

Pin
Transmit Cable Signal Connection
Conductor Color
Pin
Receive Cable Signal Connection
Conductor Color

1

TX11-

blue-black

49

TX21-

blue-violet

2

TX11+

black-blue

50

TX21+

violet-blue

3

TX10-

gray-red

51

TX20-

gray-yellow

4

TX10+

red-gray

52

TX20+

yellow-gray

5

TX9-

brown-red

53

TX19-

brown-yellow

6

TX9+

red-brown

54

TX19+

yellow-brown

7

TX8-

green-red

55

TX18-

green-yellow

8

TX8+

red-green

56

TX18+

yellow-green

9

TX7-

orange-red

57

TX17-

orange-yellow

10

TX7+

red-orange

58

TX17+

yellow-orange

11

TX6-

blue-red

59

TX16-

blue-yellow

12

TX6+

red-blue

60

TX16+

yellow-blue

13

TX5-

gray-white

61

TX15-

gray-black

14

TX5+

white-gray

62

TX15+

black-gray

15

TX4-

brown-white

63

TX14-

brown-black

16

TX4+

white-brown

64

TX14+

black-brown

17

TX3-

green-white

65

TX13-

green-black

18

TX3+

white-green

66

TX13+

black-green

19

TX2-

orange-white

67

TX12-

orange-black

20

TX2+

white-orange

68

TX12+

black-orange

21

TX1-

blue-white

69

Unused

22

TX1+

white-blue

70

Unused

23

Unused

71

Unused

24

Unused

72

Unused

25

RX11-

blue-black

73

RX21-

blue-violet

26

RX11+

black-blue

74

RX21+

violet-blue

27

RX10-

gray-red

75

RX20-

gray-yellow

28

RX10+

red-gray

76

RX20+

yellow-gray

29

RX9-

brown-red

77

RX19-

brown-yellow

30

RX9+

red-brown

78

RX19+

yellow-brown

31

RX8-

green-red

79

RX18-

green-yellow

32

RX8+

red-green

80

RX18+

yellow-green

33

RX7-

orange-red

81

RX17-

orange-yellow

34

RX7+

red-orange

82

RX17+

yellow-orange

35

RX6-

blue-red

83

RX16-

blue-yellow

36

RX6+

red-blue

84

RX16+

yellow-blue

37

RX5-

gray-white

85

RX15-

gray-black

38

RX5+

white-gray

86

RX15+

black-gray

39

RX4-

brown-white

87

RX14-

brown-black

40

RX4+

white-brown

88

RX14+

black-brown

41

RX3-

green-white

89

RX13-

green-black

42

RX3+

white-green

90

RX13+

black-green

43

RX2-

orange-white

91

RX12-

orange-black

44

RX2+

white-orange

92

RX12+

black-orange

45

RX1-

blue-white

93

Unused

46

RX1+

white-blue

94

Unused

47

Unused

95

Unused

48

Unused

96

Unused


A.1.11  DS3/EC1 Interface

Three DS3 (44.736 Mbps)/EC1 (51.84 Mbps) ports

Connector: 75-ohm mini-BNC connector

Ports can be any combination of DS-3 and EC-1

A.1.12  Nonvolatile Memory

128 MB, Compact Flash card

A.1.13  BITS Interface

1 DS-1 BITS input

1 derived DS-1 output

A.1.14  RJ-45 Connector Pin Assignments

Table A-3 details wiring for the BITS.

Table A-3 RJ-45 Connector Pin Assignments

Pin
Connector
 
BITS
ALARM
CRAFT
UDC
LAN
 
RS232 Mode
64K Mode
 

1

BITS Output +

Alarm Contact Port 1 +

RTS

NC

TX +

TX +

2

BITS Output -

Alarm Contact Port 1 -

DTR

DTR

TX -

TX -

3

BITS Input +

Alarm Contact Port 2 +

TXD

TXD

RX +

RX +

4

Alarm Contact Port 2 -

GND

GND

GND

NC

5

Alarm Input Port 1

GND

GND

GND

NC

6

BITS Input -

Alarm Input Port 2

RXD

RXD

RX -

RX -

7

Alarm Input Port 3

DSR

NC

NC

NC

8

Alarm Input Common

CTS

NC

NC

NC


A.1.15  Pushbuttons

Lamp test: when momentarily pushed, lights all LEDs on the ONS 15310-CL front panel. If an LED has more than one color, all the colors will be cycled when the lamp test button is pushed.


Note Another use for the lamp test button is to reset the CTC password to its default value (otbu+1). To reset the password, press the lamp test button for at least five seconds, release it for a maximum of five seconds, then press it again for at least five seconds. After the button is released, the default password is set.


System reset: when pressed, performs a soft reset (does not impact traffic).

A.1.16  System Timing

+/- 20 ppm SONET Minimum Clock (SMC) free-running internal clock

Maintains SMC holdover (+/- 4.6 ppm for first 24 hours) in the event of reference frequency loss

Timing reference: External BITS, line optical port, any DS-1 clock, and internal clock

A.1.17  Power Specifications

Input power: -48 VDC (dual DC power supply model) or 100/240 VAC (AC power model)

Maximum power consumption

DC chassis with no expansion board: 60W

DC chassis with expansion board: 115W

AC chassis with no expansion board: 70W

AC chassis with expansion board: 140W

Power requirements: -42 to -56 VDC or 100/240 VAC (+/- 10%)

Power terminals: Three-prong male locking connector for DC power supply model or three-prong male AC connector for AC power model


Note An ONS 15310-CL that uses DC power is classified as DC-I (DC Isolated). This means that the DC return (RET) conductor at the DC power input connector is not bonded to the chassis frame ground.


A.1.18  Environmental Specifications

Operating Temperature: 0 to +55 degrees Celsius (32 to +131 degrees Fahrenheit) for AC chassis; -40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit) for dual DC chassis.

Operating Humidity: 5 to 95%, non-condensing

A.1.19  Shelf Dimensions

Height: 1 Rack Unit (RU), 1.75 inches (4.45 cm)

Width:

19.0 inches (48.3 cm)

23.0 inches (58.4 cm) including rackmount brackets

Depth:

15.0 inches (38.1 cm) sheet metal only

15.8 inches (40.2) including mini-BNC and DC inlet connectors

Weight:

11.5 lb. empty

12.5 lb. maximum (line card installed)

A.2  Card Specifications

This section provides specifications for the cards that can be installed in the 15310-CL expansion slot: CE-100T-8, ML-100T-8, and Filler cards. For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.2.1  CE-100T-8 and ML-100T-8 Cards

Environmental

Operating temperature

C-Temp: 0 to +55 degrees Celsius (32 to 131 degrees Fahrenheit)

Operating humidity: 5 to 95%, noncondensing

Power consumption: 1.10A, 53 W

Dimensions

Height: 176 mm (6.93 in.)

Width: 34.29 mm (1.35 in.)

Depth: 238.25 mm (9.38 in.)

Weight (not including clam shell): 0.499 kg (1.1 lb)

A.2.2  Filler Card

Environmental

Operating temperature

I-Temp: -40 to +65 degrees Celsius (-40 to 149 degrees Fahrenheit)

Operating humidity: 5 to 95%, noncondensing

Dimensions

Height: 176 mm (6.93 in.)

Width: 34.29 mm (1.35 in.)

Depth: 238.25 mm (9.38 in.)

Card weight (not including clam shell): 0.45 kg (0.9 lb)

A.3  SFP Specifications

Table A-4 lists specifications for available small-form factor pluggables (SFPs) that can be used with the 15310-CL-CTX card. The 15310-CL-CTX card does not have a faceplate because it is located inside the chassis; therefore, the two SFP slots are located on the 15310-CL faceplate, just to the left of the LAN port.

Table A-4 SFP Specifications 

SFP Product ID
Interface
Transmitter Output Power Min/Max (dBm)
Receiver Input Power Min/Max (dBm)

ONS-SI-155-L1

OC-3

-5.0 to 0

-34 to -10

ONS-SI-155-L2

OC-3

-5.0 to 0

-34 to -10

ONS-SI-155-I1

OC-3

-15 to -8.0

-28 to -8

ONS-SI-622-L1

OC-12

-3.0 to 2.0

-28 to -8

ONS-SI-622-L2

OC-12

-3.0 to 2.0

-28 to -8

ONS-SI-622-I1

OC-12/OC-3

-15 to -8.0

-28 to -8


Table A-5 provides cabling specifications for the 15310-CL-CTX single-mode fiber (SMF) SFPs. The ports of the listed SFPs have LC-type connectors.

Table A-5 Single-Mode Fiber SFP Port Cabling Specifications 

SFP Product ID
Wavelength1
Fiber Type
Cable Distance

ONS-SI-155-L1
Long Reach

1310 nm

9 micro SMF

50 km (31.07 miles)

ONS-SI-155-L2
Long Reach

1550 nm

9 micro SMF

100 km (62.15 miles)

ONS-SI-155-I1
Intermediate Reach

1310 nm

9 micro SMF

21 km (13.05 miles)

ONS-SI-622-L1
Long Reach

1310 nm

9 micro SMF

42 km (26.10 miles)

ONS-SI-622-L2
Long Reach

1550 nm

9 micro SMF

85 km (52.82 miles)

ONS-SI-622-I1
Intermediate Reach

1310 nm

9 micro SMF

21 km (13.05 miles)

1 Typical loss on a 1310 nm wavelength SMF is .6 dB/km.