Cisco ONS 15310-CL Reference Manual, Release 6.0
Chapter 10, Alarm Monitoring and Management

Table Of Contents

Alarm Monitoring and Management

10.1  Overview

10.2  Viewing Alarms

10.2.1  Viewing Alarms With Each Node's Time Zone

10.2.2  Controlling Alarm Display

10.2.3  Filtering Alarms

10.2.4  Viewing Alarm-Affected Circuits

10.2.5  Conditions Tab

10.2.6  Controlling the Conditions Display

10.2.7  Viewing History

10.3  Alarm Severities

10.4  Alarm Profiles

10.4.1  Creating and Modifying Alarm Profiles

10.4.2  Alarm Profile Buttons

10.4.3  Alarm Profile Editing

10.4.4  Alarm Severity Options

10.4.5  Row Display Options

10.4.6  Applying Alarm Profiles

10.5  Alarm Suppression

10.6  External Alarms and Controls

10.6.1  External Alarm Input

10.6.2  External Control Output


Alarm Monitoring and Management


This chapter describes Cisco Transport Controller (CTC) alarm management. To troubleshoot specific alarms, refer to the Cisco ONS 15310-CL Troubleshooting Guide. Chapter topics include:

Overview

Viewing Alarms

Alarm Severities

Alarm Profiles

Alarm Suppression

External Alarms and Controls

10.1  Overview

Cisco Transport Controller (CTC) detects and reports SONET alarms generated by the Cisco ONS 15310-CL and the larger SONET network. You can use CTC to monitor and manage alarms at the card, node, or network level. Default alarm severities conform to the Telcordia GR-253 standard, but you can set alarm severities in customized alarm profiles or suppress CTC alarm reporting. For a detailed description of the standard Telcordia categories employed by Optical Networking System (ONS) nodes, refer to the Cisco ONS 15310-CL Troubleshooting Guide.


Note ONS 15310-CL alarms can also be monitored and managed through Transaction Language One (TL1) or a network management system (NMS).


10.2  Viewing Alarms

You can use the Alarms tab to view card, node, or network-level alarms. The Alarms window shows alarms in conformance with Telcordia GR-253. This means that if a network problem causes two alarms, such as loss of frame (LOF) and loss of signal (LOS), CTC only shows the LOS alarm in this window because it supersedes the LOF and replaces it.

The Path Width column in the Alarms and Conditions tabs expands upon alarmed object information contained in the access identifier (AID) string (such as "STS-4-1-3") by giving the number of synchronous transport signals (STSs) contained in the alarmed path. For example, the Path Width will tell you whether a Critical alarm applies to an STS1 or an STS48c. The column reports the width as a 1, 3, 6, 12, 48, etc. as appropriate, understood to be "STS-N."

Table 10-1 lists the Alarms tab column headings and the information recorded in each column.

Table 10-1 Alarms Column Descriptions 

Column
Information Recorded

New

Indicates a new alarm. To change this status, click either the Synchronize button or the Delete Cleared Alarms button.

Date

Date and time of the alarm.

Node

Node where the alarm occurred (appears only in network view).

Object

TL1 AID for the alarmed object. For an STSmon or VTmon, this is the monitored STS or VT object, which is explained in Table 10-3.

Eqpt Type

Card type in this slot.

Slot

Slot where the alarm occurred (appears only in network and node view).

Port

Port where the alarm is raised. For STSTerm and VTTerm, the port refers to the upstream card it is partnered with.

Path Width

Indicates how many STSs are contained in the alarmed path. This information compliments the alarm object notation, which is explained in Table 10-3.

Sev

Severity level: CR (Critical), MJ (Major), MN (Minor), NA (Not-Alarmed), NR (Not-Reported).

ST

Status: R (raised), C (clear).

SA

When checked, indicates a service-affecting alarm.

Cond

The error message/alarm name. These names are alphabetically defined in the "Alarm Troubleshooting" chapter of the Cisco ONS 15310-CL Troubleshooting Guide.

Description

Description of the alarm.

Num

Num (number) is the quantity of alarm messages received and is increments automatically as alarms occur to display the current total of received error messages.

Ref

Ref (reference) is a unique identification number assigned to each alarm to reference a specific alarm message that is displayed.


Table 10-2 lists the color codes for alarm and condition severities. In addition to the severities listed in the table, CTC alarm profiles list inherited (I) and unset (U) severities. These are only listed in the network view Provisioning > Alarm Profiles tab and are not currently implemented.

Table 10-2 Color Codes for Alarm and Condition Severities 

Color
Description

Red

Raised Critical (CR) alarm

Orange

Raised Major (MJ) alarm

Yellow

Raised Minor (MN) alarm

Magenta

Raised Not-Alarmed (NA) condition

Blue

Raised Not-Reported (NR) condition

White

Cleared (C) alarm or condition


In network view, CTC identifies STS and VT alarm objects using a TL1-type AID, as shown in Table 10-3.

Table 10-3 STS and Alarm Object Identification

STS and VT Alarm Numbering (ONS 15310-CL)
MON Object
(Optical)
Syntax and Examples

OC3/OC12 STS

Syntax: STS-<Slot>-<Ppm>-<Port>-<STS>
Ranges: STS-{2}-{1-2}-{1}-{1-n}1

Example: STS-2-1-1-6

OC3/OC12 VT

Syntax: VT1-<Slot>-<Ppm>-<Port>-<STS>-<VT Group>-<VT>
Ranges: VT1-{2}-{1-2}-{1}-{1-n1}-{1-7}-{1-4}

Example: VT1-2-1-1-6-1-1

EC1 STS

Syntax: STS-<Slot>-<Port>-<STS>
Ranges: STS-{2}-{1-3}-{1-n}1

Example: STS-2-1-6

EC1 VT

Syntax: VT1-<Slot>-<Port>-<STS>-<VT Group>-<VT>
Ranges: VT1-{2}-{1-3}-{1-n}1-{1-7}-{1-4}

Example: VT1-2-1-6-1-1

TERM Object
(Electrical)
Syntax and Examples

T1 STS

Syntax: STS-<Slot>-<STS>
Ranges: STS-{2}-{1-n}1

Example: STS-2-6

T1 VT

Syntax: VT1-<Slot>-<STS>-VT Group>-<VT>
Ranges: VT1-{2}-{1-n}1-{1-7}-{1-3}

Example: VT1-2-6-1-1

T3 STS

Syntax: STS-<Slot>-<Port>-<STS>
Ranges: STS-{2}-{1-3}-{1-n}1

Example: STS-2-1-6

T3 VT

VT not supported

1 The maximum number of STSs depends on the rate and size of the STS.


10.2.1  Viewing Alarms With Each Node's Time Zone

By default, alarms and conditions are displayed with the time stamp of the CTC workstation where you are viewing them. But you can set the node to report alarms (and conditions) using the time zone where the node is located by clicking Edit > Preferences, and clicking the Display Events Using Each Node's Timezone check box.

10.2.2  Controlling Alarm Display

You can control the display of the alarms shown in the Alarms window. Table 10-4 shows the actions you can perform in the Alarms window.

Table 10-4 Alarm Display 

Button/Check box/Tool
Action

Filter button

Allows you to change the display in the Alarms window to show only alarms that meet a certain severity level, occur in a specified time frame, and/or reflect specific conditions. For example, you can set the filter so that only Critical alarms are displayed in the window.

If you enable the Filter feature by clicking the Filter tool in one CTC view, such as node view, it is enabled in the others as well (card view and network view).

Synchronize button

Updates the alarm display. Although CTC displays alarms in real time, the Synchronize button allows you to verify the alarm display. This is particularly useful during provisioning or troubleshooting.

Delete Cleared Alarms button

Deletes alarms that have been cleared.

AutoDelete Cleared Alarms check box

If checked, CTC automatically deletes cleared alarms.

Filter tool

Enables or disables alarm filtering in the card, node, or network view. When enabled or disabled, this state applies to other views for that node and for all other nodes in the network. For example, if the Filter tool is enabled in the node (default login) view Alarms window, the network view Alarms window and card view Alarms window also show the tool enabled. All other nodes in the network also show the tool enabled.


10.2.3  Filtering Alarms

The alarm display can be filtered to prevent the display of alarms with certain severities or alarms that occurred between certain dates. You can set the filtering parameters by clicking the Filter button at the bottom-left of the Alarms window. You can turn the filter on or off by clicking the Filter tool at the bottom-right of the window. CTC retains your filter activation setting. For example, if you turn the filter on and then log out, CTC keeps the filter active the next time you log in.

10.2.4  Viewing Alarm-Affected Circuits

To view which ONS 15310-CL circuits are affected by a specific alarm, right-clicking an alarm in the Alarm window. A shortcut menu appears (Figure 10-1). When you select the Select Affected Circuits option, the Circuits window opens to show the circuits that are affected by the alarm.

Figure 10-1 Select Affected Circuits Option

10.2.5  Conditions Tab

The Conditions window displays retrieved fault conditions. A condition is a fault or status detected by ONS 15310-CL hardware or software. When a condition occurs and continues for a minimum period, CTC raises a condition, which is a flag showing that this particular condition currently exists on the ONS 15310-CL.

The Conditions window shows all conditions that occur, including those that are superseded. For instance, if a network problem causes two alarms, such as LOF and LOS, CTC shows both the LOF and LOS conditions in this window (even though LOS supersedes LOF). Having all conditions visible can be helpful when troubleshooting the ONS 15310-CL. If you want to retrieve conditions that obey a root-cause hierarchy (that is, LOS supersedes and replaces LOF), you can exclude the same root causes by checking a check box in the window.

Fault conditions include reported alarms and Not-Reported or Not-Alarmed conditions. Refer to the trouble notifications information in the Cisco ONS 15310-CL Troubleshooting Guide for more information about alarm and condition classifications.

10.2.6  Controlling the Conditions Display

You can control the display of the conditions on the Conditions window. Table 10-5 shows the actions you can perform in the window.

Table 10-5 Conditions Display 

Button
Action

Retrieve

Retrieves the current set of all existing fault conditions, as maintained by the alarm manager, from the ONS 15310-CL.

Filter

Allows you to change the Conditions window display to only show the conditions that meet a certain severity level or occur in a specified time. For example, you can set the filter so that only Critical conditions display on the window.

There is a Filter tool on the lower-right of the window that allows you to enable or disable the filter feature.


10.2.6.1  Retrieving and Displaying Conditions

The current set of all existing conditions maintained by the alarm manager can be seen when you click the Retrieve button. The set of conditions retrieved is relative to the view. For example, if you click the button while displaying the node view, node-specific conditions appear. If you click the button while displaying the network view, all conditions for the network (including ONS 15310 nodes and other connected nodes) appear, and the card view shows only card-specific conditions.

You can also set a node to display conditions using the time zone where the node is located, rather than the time zone of the PC where they are being viewed. See the "Viewing Alarms With Each Node's Time Zone" section for more information.

10.2.6.2  Conditions Column Descriptions

Table 10-6 lists the Conditions window column headings and the information recorded in each column.

Table 10-6 Conditions Column Description 

Column
Information Recorded

New

Indicates a new condition.

Date

Date and time of the condition.

Object

TL1 AID for the condition object. For an STSmon or VTmon, this is the monitored STS or VT object, which is explained in Table 10-3.

Eqpt Type

Card type in this slot.

Slot

Slot where the condition occurred (appears only in network and node view).

Port

Port where the condition occurred. For STSTerm and VTTerm, the port refers to the upstream card it is partnered with.

Sev1

Severity level: CR (Critical), MJ (Major), MN (Minor), NA (Not-Alarmed), NR (Not-Reported).

SA1

Indicates a service-affecting alarm (when checked).

Cond

The error message/alarm name; these names are alphabetically defined in the Cisco ONS 15310-CL Troubleshooting Guide.

Description

Description of the condition.

Node

Node where the alarm occurred (appears only in network view).

1 All alarms, their severities, and service-affecting statuses are also displayed in the Condition tab unless you choose to filter the alarm from the display using the Filter button.


10.2.6.3  Filtering Conditions

The condition display can be filtered to prevent the appearance of conditions (including alarms) with certain severities or that occurred between certain dates. You can set the filtering parameters by clicking the Filter button at the bottom-left of the Conditions window. You can turn the filter on or off by clicking the Filter tool at the bottom-right of the window. CTC retains your filter activation setting. For example, if you turn the filter on and then log out, CTC keeps the filter active the next time you log in.

10.2.7  Viewing History

The History window displays historic alarm or condition data for the node or for your login session. You can chose to display only alarm history, only events, or both by checking check boxes in the History > Node window. You can view network-level alarm and condition history, such as for circuits, at that level. At the node level, you can see all port (facility), card, STS, and system-level history entries. For example, protection-switching events or performance-monitoring threshold crossings appear here. If you double-click a card, you can view all port, card, and STS alarm or condition history that directly affects the port.

The ONS 15310-CL can store up to 640 Critical alarm messages, 640 Major alarm messages, 640 Minor alarm messages, and 640 condition messages. When any of these limits is reached, the ONS 15310-CL discards the oldest events in that category.


Note In the Preference dialog General tab, the Maximum History Entries value only applies to the Session window.


Different views of CTC display different kinds of history:

The History > Session window is shown in network view, node view, and card view. It shows alarms and conditions that occurred during the current user CTC session.

The History > Node window is only shown in node view. It shows the alarms and conditions that occurred on the node since CTC software was operated on the node.

The History > Card window is only shown in card view. It shows the alarms and conditions that occurred on the card since CTC software was installed on the node.


Tip Double-click an alarm in the History window to display the corresponding view. For example, double-clicking a card alarm takes you to card view. In network view, double-clicking a node alarm takes you to node view.


If you check the History window Alarms check box, you display the node history of alarms. If you check the Events check box, you display the node history of Not Alarmed and transient events (conditions). If you check both check boxes, you retrieve node history for both.

10.2.7.1  History Column Descriptions

Table 10-7 lists the History window column headings and the information recorded in each column.

Table 10-7 History Column Description 

Column
Information Recorded

Num

An incrementing count of alarm or condition messages. (The column is hidden by default; to view it, right-click a column and choose Show Column > Num.)

Ref

The reference number assigned to the alarm or condition. (The column is hidden by default; to view it, right-click a column and choose Show Column > Ref.)

Date

Date and time of the condition.

Object

TL1 AID for the condition object. For an STSmon or VTmon, this is the monitored STS or VT object, which is explained in Table 10-3.

Sev

Severity level: Critical (CR), Major (MJ), Minor (MN), Not-Alarmed (NA), Not-Reported (NR).

Eqpt Type

Card type in this slot (only displays in network view and node view).

ST

Status: raised (R), cleared (C), or transient (T).

Description

Description of the condition.

Port

Port where the condition occurred. For STSTerm and VTTerm, the port refers to the upstream card it is partnered with.

Cond

Condition name.

Slot

Slot where the condition occurred (only displays in network view and node view).

SA

A service-affecting alarm (when checked).


10.2.7.2  Retrieving and Displaying Alarm and Condition History

You can retrieve and view the history of alarms and conditions, as well as transients (passing notifications of processes as they occur) in the CTC history window. The information in this window is specific to the view where it is shown (that is, network history in the network view, node history in the node view, and card history in the card view).

The node and card history views are each divided into two tabs. In node view, when you click the Retrieve button, you can see the history of alarms, conditions, and transients that have occurred on the node in the History > Node window, and the history of alarms, conditions, and transients that have occurred on the node during your login session in the History > Session window. In the card-view history window, after you retrieve the card history, you can see the history of alarms, conditions, and transients on the card in the History > Card window, or a history of alarms, conditions, and transients that have occurred during your login session in the History > Session window. You can also filter the severities and occurrence period in these history windows.

10.3  Alarm Severities

The ONS 15310-CL alarm severities follow the Telcordia GR-253 standard, so a condition may be Alarmed at a severity of Critical (CR), Major (MJ), or Minor (MN) with a severity of Not Alarmed (NA) or Not Reported (NR). These severities are reported in the CTC software Alarms, Conditions, and History windows at all levels: network, node, and card.

ONS equipment provides a standard profile named "Default" that lists all alarms and conditions with severity settings based on Telcordia GR-253-CORE and other standards, but users can create their own profiles with different settings for some or all conditions and apply these wherever needed. (See the "Alarm Profiles" section for more information.) For example, in a custom alarm profile, the default severity of a carrier loss (CARLOSS) alarm on an Ethernet port can be changed from Major to Critical.

Critical and Major severities are only used for service-affecting alarms. If a condition is set as Critical or Major by profile, it will raise as a Minor alarm in the following situations:

In a protection group, if the alarm is on a standby entity (side not carrying traffic)

If the alarmed entity has no traffic provisioned on it, so no service is lost

Because the alarm might be raised at two different levels, the alarm profile pane shows Critical as "CR / MN" and Major as "MJ / MN."

10.4  Alarm Profiles

The alarm profiles feature allows you to change default alarm severities by creating unique alarm profiles for individual ONS 15310-CL ports, cards, or nodes. A created alarm profile can be applied to any node on the network. Alarm profiles can be saved to a file and imported elsewhere in the network, but the profile must be stored locally on a node before it can be applied to the node, cards, or ports.

CTC can store up to ten active alarm profiles at any time to apply to the node. Custom profiles can take eight of these active profile positions. Two other profiles, Default profile and Inherited profile, are reserved by the NE, and cannot be edited. The reserved Default profile contains Telcordia GR-253 severities. The reserved Inherited profile allows port alarm severities to be governed by the card-level severities, or card alarm severities to be determined by the node-level severities.

If one or more alarm profiles is stored as files from elsewhere in the network onto the local PC or server hard drive where CTC resides, you can use as many profiles as you can physically store by deleting and replacing them locally in CTC so that only eight are active at any given time.

10.4.1  Creating and Modifying Alarm Profiles

Alarm profiles are created in the network view using the Provisioning > Alarm Profiles tabs. A default alarm severity following Telcordia GR-253 standards is preprovisioned for every alarm. After loading the default profile or another profile on the node, you can use the Clone feature to create custom profiles. After the new profile is created, the Alarm Profiles window shows the original profile—frequently Default—and the new profile.


Note All default or user-defined severity settings that are Critical (CR) or Major (MJ) are demoted to Minor (MN) in non-service affecting situations as defined in Telcordia GR-474.



Tip To see the full list of profiles including those available for loading or cloning, click the Available button. You must load a profile before you can clone it.


Wherever it is applied, the Default alarm profile sets severities to standard Telcordia GR-253 settings. In the Inherited profile, alarms inherit, or copy severity from the next-highest level. For example, a card with an Inherited alarm profile copies the severities used by the node housing the card. If you choose the Inherited profile from the network view, the severities at the lower levels (node and card) are copied from this selection.

You do not have to apply a single severity profile to the node, card, and port level alarms. Different profiles can be applied at different levels. For example, you could use the inherited or default profile on a node and on all cards and ports, but apply a custom profile that downgrades an alarm on one particular card. Or you might choose to downgrade an OC-N unequipped path alarm (UNEQ-P) from Critical (CR) to Not Alarmed (NA) on an optical card because this alarm is raised and then clears every time you create a circuit. UNEQ-P alarms for the card with the custom profile would not display on the Alarms tab (but they would still be recorded on the Conditions and History tabs).

When you modify severities in an alarm profile:

All Critical (CR) or Major (MJ) default or user-defined severity settings are demoted to Minor (MN) in Non-Service-Affecting (NSA) situations as defined in Telcordia GR-474.

Default severities are used for all alarms and conditions until you create a new profile and apply it.

10.4.2  Alarm Profile Buttons

The Alarm Profiles window displays six buttons at the bottom. Table 10-8 lists and describes each of the alarm profile buttons and their functions.

Table 10-8 Alarm Profile Buttons 

Button
Description

New

Adds a new alarm profile.

Load

Loads a profile from a node or a file.

Store

Saves profiles on a node (or nodes) or in a file.

Delete

Deletes profiles from a node.

Compare

Displays differences between alarm profiles (for example, individual alarms that are not configured equivalently between profiles).

Available

Displays all profiles available on each node.

Usage

Displays all entities (nodes and alarm subjects) present in the network and which profiles contain the alarm. Can be printed.


10.4.3  Alarm Profile Editing

Table 10-9 lists and describes the five profile-editing options available when you right-click an alarm item in the profile column (such as Default).

Table 10-9 Alarm Profile Editing Options 

Button
Description

Store

Saves a profile in a node or in a file.

Rename

Changes a profile name.

Clone

Creates a profile that contains the same alarm severity settings as the profile being cloned.

Reset

Restores a profile to its previous state or to the original state (if it has not yet been applied).

Remove

Removes a profile from the table editor.


10.4.4  Alarm Severity Options

To change or assign alarm severity, left-click the alarm severity you want to change in the alarm profile column. Seven severity levels appear for the alarm:

Not-reported (NR)

Not-alarmed (NA)

Minor (MN)

Major (MJ)

Critical (CR)

Use Default

Inherited (I)

Inherited and Use Default severity levels only appear in alarm profiles. They do not appear when you view alarms, history, or conditions.

10.4.5  Row Display Options

In the network view, the Alarm Profiles window displays two check boxes at the bottom of the window:

Hide reference values—Highlights alarms with non-default severities by clearing alarm cells with default severities.

Hide identical rows—Hides rows of alarms that contain the same severity for each profile.

10.4.6  Applying Alarm Profiles

In CTC node view, the Alarm Behavior window displays alarm profiles for the node. In card view, the Alarm Behavior window displays the alarm profiles for the selected card. Alarm profiles form a hierarchy. A node alarm profile applies to all cards in the node except cards that have their own profiles. A card alarm profile applies to all ports on the card except ports that have their own profiles.

At the node level, you can apply profile changes on a card-by-card basis or set a profile for the entire node. At the card view, you can apply profile changes on a port-by-port basis or set alarm profiles for all ports on that card. Figure 10-2 shows the CE-100T-8 card alarm profiles.

Figure 10-2 Alarm Profiles for a CE-100T-8 Card

10.5  Alarm Suppression

ONS 15310 nodes have an alarm suppression option that clears raised alarm messages for the node, chassis, one or more slots (cards), or one or more ports. After they are cleared, these alarms change appearance from their normal severity color to white and they can be cleared from the display by clicking Synchronize. Alarm suppression itself raises an alarm called AS-CMD that is shown in applicable Alarms windows. Node-level suppression is shown in the node-view Alarms window, and card or port level suppression is shown in all views. The AS-CMD alarm itself is not cleared by the suppress command. Each instance of this alarm indicates its object separately in the Object column.

A suppression command applied at a higher level does not supersede a command applied at a lower level. For example, applying a node-level alarm suppression command makes all raised alarms for the node appear cleared, but it does not cancel card level or port level suppression. Each of these conditions can exist independently and must be cleared independently.

Suppression causes the entity alarm to behave like a Not-Reported event. This means that the alarms, having been suppressed from view in the Alarms window, are now only shown in the Conditions window. The suppressed alarms are displayed with their usual visual characteristics (service-affecting status and color-coding) in the window. The alarms still appear in the History window.


Note Use alarm suppression with caution. If multiple CTC or TL1 sessions are open, suppressing the alarms in one session suppresses the alarms in all other open sessions.


10.6  External Alarms and Controls

External alarm physical connections are made with the 15310-CL ALARM port. However, the alarms are provisioned using the 15310-CL-CTX card view for external sensors such as an open door and flood sensors, temperature sensors, and other environmental conditions. External control outputs on the 15310-CL-CTX card allow you to drive external visual or audible devices such as bells and lights. They can control other devices such as generators, heaters, and fans.

Provision external alarms in the 15310-CL-CTX card view Provisioning > External Alarms tab and provision controls in the 15310-CL-CTX card view Provisioning > External Controls tab. Up to 32 alarm contact inputs and 8 alarm contact outputs are available with the CTX2500 cards and 15310-CL-CTX cards report some of these alarms.

10.6.1  External Alarm Input

You can provision each alarm input separately. Provisionable characteristics of external alarm inputs include:

Alarm type

Alarm severity (CR, MJ, MN, NA, and NR)

Alarm-trigger setting (open or closed); open means that the normal condition is to have current flowing through the contact, and the alarm is generated when the current stops flowing; closed means that normally no current flows through the contact, and the alarm is generated when current does flow.

Virtual wire associated with the alarm

CTC alarm log description (up to 63 characters)


Note If you provision an external alarm to raise when a contact is open, and you have not attached the alarm cable, the alarm will remain raised until the alarm cable is connected.



Note When you provision an external alarm, the alarm object is ENV-IN-nn. The variable nn refers to the external alarm's number, regardless of the name you assign.


10.6.2  External Control Output

You can provision each alarm output separately. Provisionable characteristics of alarm outputs include:

Control type

Trigger type (alarm or virtual wire)

Description for CTC display

Closure setting (manually or by trigger). If you provision the output closure to be triggered, the following characteristics can be used as triggers:

Local NE alarm severity—A chosen alarm severity (for example, Major) and any higher-severity alarm (in this case, Critical) causes output closure

Remote NE alarm severity—Similar to local NE alarm severity trigger setting, but applies to remote alarms

Virtual wire entities—You can provision an alarm that is input to a virtual wire to trigger an external control output