本文档介绍如何在Catalyst 9800无线局域网控制器(WLC)上配置离线(气隙)许可。
有关9800 WLC和思科许可证中心门户基本操作的建议知识。
本文档中的信息基于以下软件和硬件版本,但适用于17.3之后的所有版本:
本文档中的信息都是基于特定实验室环境中的设备编写的。本文档中使用的所有设备最初均采用原始(默认)配置。如果您的网络处于活动状态,请确保您了解所有命令的潜在影响。

1.将许可连接模式设置为AirGap,并将AirGap功能设置为Enabled:

The CLI equivalent is:
9800-17-09-05(config)#license smart transport off
2.从WLC导出RUM报告。这会将您当前的许可证使用量保存到文件:
9800-17-09-05#license smart save usage all file bootflash:rum.txt
1.登录您的思科许可证中心帐户。
2.依次导航至Reports选项卡和Usage Data Files。单击Usage Data Files:

3.单击Browse,然后选择从WLC获取的RUM报告。单击Upload Data:

4.将RUM报告上传到思科许可证中心后,确认列下会显示下载按钮。单击Download:

在WLC上导入ACK:
9800-17-09-05#license smart import bootflash:ACK_rum.txt
Import Data Successful
注意:重置许可证工厂后,必须至少等待1小时生成RUM报告。
应用上述配置步骤后,WLC将显示在思科许可证中心的资产>产品实例下。
如果注册了HA对中的活动WLC,则活动和备用WLC都会显示在思科许可证中心的产品实例选项卡下。
成功配置的WLC的输出示例:
------------------ show license status ------------------
Utility:
Status: DISABLED
Smart Licensing Using Policy:
Status: ENABLED
Account Information:
Smart Account: As of Feb 29 15:24:40 2024 UTC
Virtual Account:
Data Privacy:
Sending Hostname: yes
Callhome hostname privacy: DISABLED
Smart Licensing hostname privacy: DISABLED
Version privacy: DISABLED
Transport:
Type: Transport Off
Policy:
Policy in use: Merged from multiple sources.
Reporting ACK required: yes (CISCO default)
Unenforced/Non-Export Perpetual Attributes:
First report requirement (days): 365 (CISCO default)
Reporting frequency (days): 0 (CISCO default)
Report on change (days): 90 (CISCO default)
Unenforced/Non-Export Subscription Attributes:
First report requirement (days): 90 (CISCO default)
Reporting frequency (days): 90 (CISCO default)
Report on change (days): 90 (CISCO default)
Enforced (Perpetual/Subscription) License Attributes:
First report requirement (days): 0 (CISCO default)
Reporting frequency (days): 0 (CISCO default)
Report on change (days): 0 (CISCO default)
Export (Perpetual/Subscription) License Attributes:
First report requirement (days): 0 (CISCO default)
Reporting frequency (days): 0 (CISCO default)
Report on change (days): 0 (CISCO default)
Miscellaneous:
Custom Id:
Usage Reporting:
Last ACK received: Feb 29 15:27:53 2024 UTC
Next ACK deadline: May 29 15:27:54 2024 UTC
Reporting push interval: 30 days
Next ACK push check:
Next report push: Mar 30 15:27:54 2024 UTC
Last report push: Feb 29 15:27:54 2024 UTC
Last report file write:
Trust Code Installed:
Active: PID:C9800-CL-K9,SN:
INSTALLED on Feb 29 15:27:53 2024 UTC
Standby: PID:C9800-CL-K9,SN:
INSTALLED on Feb 29 15:27:53 2024 UTC
如果RUM上传到思科许可证中心门户失败,可能是因为WLC已通过门户上的直接连接注册。从思科许可证中心资产中删除设备。然后您可以上传RUM报告。