Cisco Firepower 4115机箱出现意外重新启动,无法恢复运行状态。观察到以下症状:
FMC UI将FTD状态显示为“Disabled”。
机箱管理器UI显示状态为Status:安全模块故障。

机箱管理器UI将安全引擎显示为Degraded。

DDR4/DIMM内存、安全模块和存储的多个相关故障显示在FXOS CLI中。
fxos# show fault
Severity Code Last Transition Time ID Description
--------- -------- ------------------------ -------- -----------
Critical F1236 2026-06-26T05:50:35.387 2443029 Health LED of server 1/1 shows error. Reason: DDR4_P1_A1_ECC:Sensor Threshold Crossed;
Major F1546 2026-06-26T22:11:30.870 2443026 Security Module 1 is in failed state. Error: Security module is downgraded (or) not acknowledged. Reason: DIMM or CPU degraded
Major F0317 2026-06-26T22:05:08.375 2443211 Server 1/1 (service profile: org-root/ls-ssp-sprof-1) health: inoperable
Major F1761 2026-06-26T05:52:40.467 2443450 Physical memory size 180224 on server 1/1 is smaller than expected.
Major F0185 2026-06-26T05:31:08.858 2442844 DIMM DIMM_A1 on server 1/1 operability: inoperable
Info F0461 2025-08-26T04:24:40.271 1895361 Log capacity on Management Controller on server 1/1 is very-low
机箱服务器和内存状态详细信息显示无法操作的DIMM组件。
fxos# show server status detail
Server 1/1:
Slot Status: Equipped
Equipped Conn Path: A
Equipped Conn Status: A
Equipped Managing Instance: A
Availability: Unavailable
Admin State: In Service
Overall Status: Degraded
Oper Qualifier: Memory Inoperable
Discovery: Complete
Current Task:
Check Point: Discovered
fxos# show server memory detail
Server 1/1:
Array 1:
CPU ID: 1
Current Capacity (MB): 180224
Error Correction: Undisc
Max Capacity (MB): 9437184
Max Devices: 24
Populated: 12
DIMMS:
ID 1:
Location: DIMM_A1
Presence: Equipped
Overall Status: Inoperable
Visibility: No
Vendor: NO DIMM
Vendor Part Number: NO DIMM
Vendor Serial (SN): NO DIMM
HW Revision: 0
Form Factor: Unknown
Type: Unknown
Capacity (MB): Unknown
Clock: Unknown
Latency: 2917376161116564280513419804672.000000
Width: 14400
思科Firepower 4100安全设备(FPR-4115-K9)
首次在FXOS版本中看到:2.14(1.167)
FTD版本:7.4.7.50(运行)、6.4.0.102(启动)
通过FMC管理实现高可用性配置
内存配置:12个16GB 2666 MHz DDR4模块
受影响的DIMM:内存插槽1中的DIMM_A1
1.执行机箱重新引导以尝试内存故障恢复:
fxos# scope chassis
fxos /chassis # reboot
fxos /chassis* # commit-buffer
2.分配系统完全启动的时间后,在FXOS CLI和机箱管理器UI中重新验证组件状态故障状态。
3.如果DIMM故障在完全重启后仍然存在,则需要通过Cisco RMA更换硬件。
诊断程序确认了一个严重内存子系统故障,其中DDR4_P1_A1_ECC传感器阈值已超过,表明在意外机箱重新启动后模块发生故障。DIMM A1报告了“不可操作”状态,所有SPD(串行存在检测)数据都不可读,确认不可逆的硬件故障,而不是通过平稳重启无法恢复的暂时性错误。内存故障导致安全模块和FTD逻辑实例无法正确初始化,导致在机箱重新启动后保持的“无法操作”机箱状态。
| 版本 | 发布日期 | 备注 |
|---|---|---|
1.0 |
02-Nov-2026
|
初始版本 |