UCS Server BIOS Tokens

Server BIOS Tokens in Release 4.2(3b)

Cisco UCS Manager continues to support the following servers in 4.2(3b):

  • C220 M6

  • C240 M6

  • C225 M6

  • C245 M6

  • B200 M6

For Cisco UCS C-series and B-series BIOS tokens supported on M4 and M5 servers, refer Cisco UCS Server BIOS Tokens, Release 4.1.

New and Changed BIOS Tokens for 4.2(3b)

Name

Default Value

M6 Server Supported Values

Platform

Dependencies

New/Changed

X2APIC Opt Out

Disabled

Disabled, Enabled

C220M6, C240M6, B200M6

New

Security Dev. Support

Enabled

Disabled, Enabled

C220M6, C240M6, C225M6, C245M6, B200M6

New

Server BIOS Tokens in Release 4.2(2c)

Cisco UCS Manager supports the following servers in 4.2(2c) release:

  • C220 M6

  • C240 M6

For Cisco UCS C-series and B-series BIOS tokens supported on M4 and M5 servers, refer Cisco UCS Server BIOS Tokens, Release 4.1.

BIOS Tokens for C220 M6 and C240 M6 in 4.2(2c)

The following table lists the new BIOS tokens for 4.2(2c) release:

Name

Default Value

M6 Server Supported Values

Platform

New/Changed

TPM Minimal Physical Presence

Disabled

Disabled, Enabled

C220 M6 and C240 M6

New

DMA Control Opt-In Flag

Disabled

Disabled, Enabled

C220 M6 and C240 M6

New

Server BIOS Tokens in Release 4.2(1m)

Cisco UCS Manager continues to support the following servers in 4.2(1m):

  • C220 M6

  • C240 M6

  • C225 M6

  • C245 M6

  • B200 M6

For Cisco UCS C-series and B-series BIOS tokens supported on M4 and M5 servers, refer Cisco UCS Server BIOS Tokens, Release 4.1.

New and Changed BIOS Tokens for 4.2(1m)

Name

Default Value

M6 Server Supported Values

Platform

Dependencies

New/Changed

Execute Disable Bit

Enabled

Disabled, Enabled

C220 M6, C240 M6, C225 M6, C245 M6, B200 M6

New

Server BIOS Tokens in Release 4.2(1l)

Cisco UCS Manager introduces support for the following servers in 4.2(1l):

  • C225 M6

Cisco UCS Manager continues to support the following servers in 4.2(1l):

  • C220 M6

  • C240 M6

  • C245 M6

  • B200 M6

For Cisco UCS C-series and B-series BIOS tokens supported on M4 and M5 servers, refer Cisco UCS Server BIOS Tokens, Release 4.1.

BIOS Tokens for C225 M6 in 4.2(1l)

Name

Default Value

M6 Server Supported Values

Platform

Dependencies

MLOM Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C225 M6

MLOM OptionROM

Enabled

Disabled, Enabled

C225 M6

PCIe Slot n Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C225 M6

The n refers to an integer from 1 to 3.

PCIe Slot n OptionROM

Enabled

Enabled, Disabled

C225 M6

The n refers to an integer from 1 to 3.

MRAID Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C225 M6

MRAID OptionROM

Enabled

Disabled, Enabled

C225 M6

Front NVME n Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C225 M6

The n refers to an integer from 1 to 10.

Front NVME-n OptionROM

Enabled

Enabled, Disabled

C225 M6

The n refers to an integer from 1 to 10.

PCIe Slot MSTOR Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C225 M6

PCIe Slot MSTOR RAID OptionROM

Enabled

Enabled, Disabled

C225 M6

Core Performance Boost

Auto

Disabled, Auto

C225 M6

Global C-state Control

Auto

Disabled, Enabled, Auto

C225 M6

L1 Stream HW Prefetcher

Auto

Disabled, Enabled, Auto

C225 M6

L2 Stream HW Prefetcher

Auto

Disabled, Enabled, Auto

C225 M6

NUMA Nodes per Socket

Auto

NPS0, NPS1, NPS2, NPS4, Auto

C225 M6

Memory Interleaving Size

Auto

256 Bytes, 512 Bytes, 1 KB, 2 KB, 4 KB, Auto

C225 M6

Chipselect Interleaving

Auto

Disabled, Auto

C225 M6

Bank Group Swap

Auto

Enabled, Disabled, Auto

C225 M6

Determinism Slider

Auto

Power, Performance, Auto

C225 M6

IOMMU

Auto

Disabled, Enabled, Auto

C225 M6

SMT Mode

Enabled

Disabled, Enabled, Auto

C225 M6

SVM Mode

Enabled

Disabled, Enabled

C225 M6

Efficiency Mode Enable

Auto

Auto, Enabled

C225 M6

SNP Memory Coverage

Auto

Auto, Enabled, Disabled, Custom

C225 M6

SNP Memory Size to Cover in MB

0

0-1048576

C225 M6

CPPC

Auto

Auto, Enabled, Disabled

C225 M6

SEV-SNP Support

Disabled

Enabled, Disabled

C225 M6

SMEE

Auto

Auto, Enabled, Disabled

C225 M6

CPU Downcore control 7xx3

Auto

Auto, ONE (1 + 0), TWO (2 + 0), THREE (3 + 0), FOUR (4 + 0), FIVE (5 + 0), SIX (6 + 0), SEVEN (7 + 0)

C225 M6

Downcore control 7xx2

Auto

Auto, TWO (1 + 1), FOUR (2 + 2), SIX (3 + 3)

C225 M6

Fixed SOC P-State

Auto

P0, P1, P2, P3, Auto

C225 M6

APBDIS

Auto

0, 1, Auto

C225 M6

CCD Control

Auto

Auto, 2 CCDs, 3 CCDs, 4 CCDs, 6 CCDs

C225 M6

Cisco xGMI Max Speed

Disabled

Disabled, Enabled

C225 M6

ACPI SRAT L3 Cache As NUMA Domain

Auto

Disabled, Enabled, Auto

C225 M6

Streaming Stores Control

Auto

Disabled, Enabled, Auto

C225 M6

DF C-States

Auto

Disabled, Enabled, Auto

C225 M6

Burst and Postponed Refresh

Disabled

Enabled, Disabled

C225 M6

SR-IOV Support

Enabled

Enabled, Disabled

C225 M6

PCIe ARI Support

Auto

Auto, Enabled, Disabled

C225 M6

TSME

Auto

Auto, Enabled, Disabled

C225 M6

BIOS Techlog Level

Minimum

Maximum, Normal, Minimum

C225 M6

OptionROM Launch Optimization

Enabled

Enabled, Disabled

C225 M6

Above 4GB Decoding

Enabled

Enabled, Disabled

C225 M6

SMEE

Enabled

Enabled, Disabled

C225 M6

SMT Mode

Off

Auto, Off

C225 M6

SR-IOV Support

Enabled

Enabled, Disabled

C225 M6

SVM Mode

Enabled

Enabled, Disabled

C225 M6

Terminal type

VT 100

PC-ANSI,VT100, VT100-PLUS, VT-UTF8

C225 M6

SHA-1 PCR Bank

Enabled

Enabled, Disabled

C225 M6

SHA256 PCR Bank

Enabled

Enabled, Disabled

C245 M6

FRB 2 Timer

Enabled

Enabled, Disabled

C225 M6

OS Boot Watchdog Timer

Enabled

Enabled, Disabled

C225 M6

OS Boot Watchdog Timer Policy

Power Off

Power Off, Reset

C225 M6

OS Boot Watchdog Timer Timeout

10 minutes

5 minutes, 10 minutes, 15 minutes, 20 minutes

C225 M6

Flow Control

None

None, RTS-CTS

C225 M6

Baud rate

115.2k

9.6k, 9.2k, 38.4k, 57.6k, 115.2k

C225 M6

Terminal type

VT100

PC-ANSI, VT100, VT100-PLUS, VT-UTF8

C225 M6

Applicable only when Console Redirection COM 0

Console redirection

Disabled

Disabled, COM0, COM1 or serial-port-b

C225 M6

Server BIOS Tokens in Release 4.2(1i)

Cisco UCS Manager introduces support for the following servers in 4.2(1i):

  • C245 M6

Cisco UCS Manager continues to support the following servers in 4.2(1i):

  • C220 M6

  • C240 M6

  • B200 M6

For Cisco UCS C-series and B-series BIOS tokens supported on M4 and M5 servers, refer Cisco UCS Server BIOS Tokens, Release 4.1.

BIOS Tokens for C245 M6 in 4.2(1i)

Name

Default Value

M6 Server Supported Values

Platform

Dependencies

MLOM Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C245 M6

MLOM OptionROM

Enabled

Disabled, Enabled

C245 M6

PCIe Slot n Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C245 M6

The n refers to an integer from 1 to 8.

PCIe Slot n OptionROM

Enabled

Enabled, Disabled

C245 M6

The n refers to an integer from 1 to 8.

MRAIDn Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C245 M6

The n refers to an integer 1 or 2.

MRAIDn OptionROM

Enabled

Disabled, Enabled

C245 M6

The n refers to an integer 1 or 2.

Front NVME n Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C245 M6

The n refers to an integer from 1 to 4.

Front NVME-n OptionROM

Enabled

Enabled, Disabled

C245 M6

The n refers to an integer from 1 to 4.

Rear NVME n Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C245 M6

The n refers to an integer from 1 to 4.

Rear NVME n OptionROM

Enabled

Enabled, Disabled

C245 M6

The n refers to an integer from 1 to 4.

PCIe Slot MSTOR Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3, GEN4

C245 M6

PCIe Slot MSTOR RAID OptionROM

Enabled

Enabled, Disabled

C245 M6

FRB 2 Timer

Enabled

Enabled, Disabled

C245 M6

OS Boot Watchdog Timer Policy

Power Off

Power Off, Reset

C245 M6

Flow Control

None

None, RTS-CTS

C245 M6

Baud rate

115.2k

9.6k, 9.2k, 38.4k, 57.6k, 115.2k

C245 M6

Terminal type

VT100

PC-ANSI, VT100, VT100-PLUS, VT-UTF8

C245 M6

Applicable only when Console Redirection COM 0

Console redirection

Disabled

COM 0, COM 1, Disabled

C245 M6

Applicable only when Console Redirection COM 0

Trusted Platform Module State

Enabled

Enabled, Disabled

C245 M6

SHA-1 PCR Bank

Enabled

Enabled, Disabled

C245 M6

SHA256 PCR Bank

Enabled

Enabled, Disabled

C245 M6

Post Package Repair

Hard PPR

Disabled, Hard PPR

C245 M6

Above 4G Decoding

Enabled

Enabled, Disabled

C245 M6

CDN Control

Enabled

Enabled, Disabled

C245 M6

OptionROM Launch Optimization

Enabled

Enabled, Disabled

C245 M6

BIOS Techlog Level

Minimum

Maximum, Normal, Minimum

C245 M6

Power ON Password

Disabled

Enabled, Disabled

C245 M6

IPV6 PXE Support

Disabled

Enabled, Disabled

C245 M6

BME DMA Mitigation

Disabled

Enabled, Disabled

C245 M6

Network Stack

Enabled

Enabled, Disabled

C245 M6

IPv4 PXE Support

Enabled

Enabled, Disabled

C245 M6

IPv4 HTTP Support

Enabled

Enabled, Disabled

C245 M6

IPv6 HTTP Support

Enabled

Enabled, Disabled

C245 M6

Core Performance Boost

Auto

Disabled, Auto

C245 M6

Global C-state Control

Auto

Disabled, Enabled, Auto

C245 M6

L1 Stream HW Prefetcher

Auto

Disabled, Enabled, Auto

C245 M6

L2 Stream HW Prefetcher

Auto

Disabled, Enabled, Auto

C245 M6

NUMA Nodes per Socket

Auto

NPS0, NPS1, NPS2, NPS4, Auto

C245 M6

Memory Interleaving Size

Auto

256 Bytes, 512 Bytes, 1 KB, 2 KB, 4 KB, Auto

C245 M6

Chipselect Interleaving

Auto

Disabled, Auto

C245 M6

Bank Group Swap

Auto

Enabled, Disabled, Auto

C245 M6

Determinism Slider

Auto

Power, Performance, Auto

C245 M6

IOMMU

Auto

Disabled, Enabled, Auto

C245 M6

SMT Mode

Enabled

Disabled, Enabled, Auto

C245 M6

SVM Mode

Enabled

Disabled, Enabled

C245 M6

Efficiency Mode Enable

Auto

Auto, Enabled

C245 M6

SNP Memory Coverage

Auto

Auto, Enabled, Disabled, Custom

C245 M6

SNP Memory Size to Cover in MB

0

0-1048576

C245 M6

CPPC

Auto

Auto, Enabled, Disabled

C245 M6

SEV-SNP Support

Disabled

Enabled, Disabled

C245 M6

SMEE

Auto

Auto, Enabled, Disabled

C245 M6

CPU Downcore control 7xx3

Auto

Auto, ONE (1 + 0), TWO (2 + 0), THREE (3 + 0), FOUR (4 + 0), FIVE (5 + 0), SIX (6 + 0), SEVEN (7 + 0)

C245 M6

Fixed SOC P-State

Auto

P0, P1, P2, P3, Auto

C245 M6

APBDIS

Auto

0, 1, Auto

C245 M6

CCD Control

Auto

Auto, 2 CCDs, 3 CCDs, 4 CCDs, 6 CCDs

C245 M6

Cisco xGMI Max Speed

Disabled

Disabled, Enabled

C245 M6

ACPI SRAT L3 Cache As NUMA Domain

Auto

Disabled, Enabled, Auto

C245 M6

Streaming Stores Control

Auto

Disabled, Enabled, Auto

C245 M6

DF C-States

Auto

Disabled, Enabled, Auto

C245 M6

Post Package Repair

Hard PPR

Disabled, Hard PPR

C245 M6

Burst and Postponed Refresh

Disabled

Enabled, Disabled

C245 M6

SR-IOV Support

Enabled

Enabled, Disabled

C245 M6

PCIe ARI Support

Auto

Auto, Enabled, Disabled

C245 M6

TSME

Auto

Auto, Enabled, Disabled

C245 M6

BIOS Techlog Level

Minimum

Maximum, Normal, Minimum

C245 M6

OptionROM Launch Optimization

Enabled

Enabled, Disabled

C245 M6

Above 4GB Decoding

Enabled

Enabled, Disabled

C245 M6

SMEE

Enabled

Enabled, Disabled

C245 M6

SMT Mode

Off

Auto, Off

C245 M6

SR-IOV Support

Enabled

Enabled, Disabled

C245 M6

SVM Mode

Enabled

Enabled, Disabled

C245 M6

Terminal type

VT 100

PC-ANSI,VT100, VT100-PLUS, VT-UTF8

C245 M6

OS Boot Watchdog Timer

Enabled

Enabled, Disabled

C245 M6

OS Boot Watchdog Timer Timeout

10 minutes

5 minutes, 10 minutes, 15 minutes, 20 minutes

C245 M6

Server BIOS Tokens in Release 4.2(1f)

Cisco UCS Manager supports the following servers in 4.2(1f) release:

  • C220 M6

  • C240 M6

  • B200 M6

The following table lists the new and updated BIOS tokens for 4.2(1f) release.

Table 1. New and Updated BIOS Tokens 4.2(1f)

Name

Default Value

Server Supported Values

Platform

New/Changed

Enhanced CPU Performance

Disabled

Disabled, Auto

C220 M6, C240 M6, and B200 M6

New

UPI Link Enablement

Auto

Auto, 1, 2

C220 M6, C240 M6, and B200 M6

New

Virtual Numa

Disabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

LLC Dead Line

Enabled

Auto, Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

C1 Auto Demotion

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

C1 Auto UnDemotion

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

XPT Remote Prefetch

Auto

Auto, Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

UPI Power Management

Disabled

Disabled, Enabled

C220 M6, C240 M6, and B200 M6

New

SHA-1 PCR Bank

Enabled

Disabled, Enabled

C220 M6, C240 M6, and B200 M6

New

SHA256-PCR-Bank

Enabled

Disabled, Enabled

C220 M6, C240 M6, and B200 M6

New

FRB 2 Timer

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

OS Boot Watchdog Timer Policy

Power Off

Power Off, Reset

C220 M6, C240 M6, and B200 M6

New

OS Boot Watchdog Timer

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

Flow Control

None

None, RTS-CTS

C220 M6, C240 M6, and B200 M6

New

Legacy USB Support

Enabled

Enabled, Disabled, Auto

C220 M6, C240 M6, and B200 M6

New

Baud rate

115.2k

9.6k, 9.2k, 38.4k, 57.6k, 115.2k

C220 M6, C240 M6, and B200 M6

New

Terminal type

VT100

PC-ANSI, VT100, VT100-PLUS, VT-UTF8

C220 M6, C240 M6, and B200 M6

New

Console redirection

Disabled

Disabled, COM0, COM1 or serial-port-b

C220 M6, C240 M6, and B200 M6

New

Trusted Platform Module Support

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

TPM Pending operation

None

None, TpmClear

C220 M6, C240 M6, and B200 M6

New

Intel VT for directed IO

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

Intel VTD coherency support

Disabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

Intel Trusted Execution Technology Support

Disabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

Intel Virtualization Technology

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

MLOM OptionROM

Enabled

Disabled, Enabled

C220 M6, C240 M6, and B200 M6

New

OS Boot Watchdog Timer Timeout

10 minutes

5 minutes, 10 minutes, 15 minutes, 20 minutes

C220 M6, C240 M6, and B200 M6

New

Select Memory RAS Configuration

ADDDC Sparing

Maximum-performance, Mirror-mode-1lm, ADDDC Sparing, Partial-mirror-mode-1lm

C220 M6, C240 M6, and B200 M6

New

Turbo Mode

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

EIST PSD Function

HW all

HW all, SW all

C220 M6, C240 M6, and B200 M6

New

Uncore Frequency Scaling

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

SpeedStep (Pstates)

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

New

LIMIT CPU PA to 46 Bits

Enabled

Enabled, Disabled

C220 M6, C240 M6, and B200 M6

Changed

Virtual NUMA

Disabled

Enabled, Disabled, Auto

C220 M6, C240 M6, and B200 M6

Changed

LLC Dead Line

Enabled

Enabled, Disabled, Auto

C220 M6, C240 M6, and B200 M6

Changed

XPT Remote Prefetch

Auto

Enabled, Disabled, Auto

C220 M6, C240 M6, and B200 M6

Changed

Slot 9 State

Disabled

Enabled, Disabled, UEFI Only, Legacy Only

C220 M6, C240 M6, and B200 M6

Changed

Server BIOS Tokens in Release 4.2(1d)

Cisco UCS Manager introduces support for the following servers in 4.2(1d):

Cisco UCS Manager continues to support the following servers in 4.2(1d):

  • B200 M5

  • B480 M5

  • C220 M5

  • C240 M5

  • C240 SD M5

  • C480 M5

  • S3260 M5

  • C125 M5

  • C480 M5 ML

  • C220 M4

  • C240 M4

  • C460 M4

  • S3260 M4

For Cisco UCS C-series and B-series BIOS tokens supported on M4 and M5 servers, refer Cisco UCS Server BIOS Tokens, Release 4.1. In addition, refer the following New and Changed BIOS Tokens for M5 servers in 4.2(1d) for updated M5 server support.

BIOS Tokens for C220 M6 and C240 M6 in 4.2(1d)

Name

Default Value

Server Supported Values

Platform

Dependencies

Core Multi Processing

All

All, 1 to 48

C220 M6 and C240 M6

CR QoS

Mode 0 - Disable the PMem QoS Feature

Recipe 1, Recipe 2, Recipe 3, Disabled, Mode 0 - Disable the PMem QoS Feature, Mode 1 - M2M QoS Enable ;CHA QoS Disable, Mode 2 - M2M QoS Enable;CHA QoS Enable

C220 M6 and C240 M6

IIO eDPC Support

OnFatal and Non-Fatal Errors

On Fatal Error, Disabled, OnFatal and Non-Fatal Errors

C220 M6 and C240 M6

Multikey Total Memory Encryption (MK-TME)

Disabled

Enabled, Disabled

C220 M6 and C240 M6

SW Guard Extensions (SGX)

Disabled

Enabled, Disabled

C220 M6 and C240 M6

Total Memory Encryption (TME)

Disabled

Enabled, Disabled

C220 M6 and C240 M6

Select Owner EPOCH input type

Manual User Defined Owner EPOCHs

SGX Owner EPOCH activated, Change to New Random Owner EPOCHs, Manual User Defined Owner EPOCHs

C220 M6 and C240 M6

UPI Prefetch

Auto

Auto, Enabled, Disabled

C220 M6 and C240 M6

Partial Cache Line Sparing

Enabled

Enabled, Disabled

C220 M6 and C240 M6

Select PPR type configuration

Hard PPR

Hard PPR, Soft PPR, Disabled

C220 M6 and C240 M6

SGX Auto MP Registration Agent

Disabled

Enabled, Disabled

C220 M6 and C240 M6

SProcessor Epochn

0

n

C220 M6 and C240 M6

SGX Factory Reset

Disabled

Enabled, Disabled

C220 M6 and C240 M6

SGX PUBKEY HASHn

0

SGX PUBKEY HASH0-Between 7-0, SGX PUBKEY HASH1-Between 15-8, SGX PUBKEY HASH2-Between 23-16, SGX PUBKEY HASH3-Between 31-24

C220 M6 and C240 M6

SGX Write Enable

Enabled

Enabled, Disabled

C220 M6 and C240 M6

SGX Pkg info In-Band Access

Disabled

Enabled, Disabled

C220 M6 and C240 M6

SGX QoS

Enabled

Enabled, Disabled

C220 M6 and C240 M6

Enhanced Memory Test

Auto

Auto, Disabled, Enabled

C220 M6 and C240 M6

Intel Dynamic Speed Select

Disabled

Enabled, Disabled

C220 M6 and C240 M6

Intel Speed Select

Base

Base, Config 1, Config 2, Config 3, Config 4

C220 M6 and C240 M6

UPI Link Frequency Select

Auto

9.6GT/s, 10.4GT/s, 11.2GT/s, Auto, Use Per Link Setting

C220 M6 and C240 M6

UMA Clustering

Hemisphere(2-clusters)

Hemisphere(2-clusters), Disable(All-2-All)

C220 M6 and C240 M6

MLOM Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C220 M6 and C240 M6

PCIe Slot MSTOR-RAID Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C220 M6 and C240 M6

MRAID Link Speed

Auto

Auto, Disabled, Enabled, GEN1, GEN2, GEN3,GEN4

C220 M6

MRAID-n Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C240 M6

The n refers to an integer from 1 to 2.

MRAID-n OptionROM

Enabled

Enabled, Disabled

C240 M6

The n refers to an integer from 1 to 2.

Front Nvme-n OptionROM

Enabled

Disabled, Enabled

For nranging from 1 to 10 supports C220 M6 and C240 M6

nranging 11 and 24 supports C240 M6

Front NVMEn Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

For nranging from 1 to 10 supports C220 M6 and C240 M6

nranging 11 and 10 supports C240 M6

The n refers to an integer from 1 to 12.

PCIe Slot n Link Speed

Auto

Auto, Disabled, GEN1,GEN2, GEN3, GEN4

C240 M6

The n refers to an integer from 4 to 8.

PCIe Slot n OptionROM

Enabled

Enabled, Disabled

C240 M6

The n refers to an integer from 4 to 8.

Rear NVMEn Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C240 M6

The n refers to an integer from 1 to 4.

Rear NVMEn Option ROM

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C240 M6

The n refers to an integer from 1 to 4.

eADR Support

Disabled

Auto, Enabled, Disabled

C220 M6 and C240 M6

Volatile Memory Mode

2LM

2LM, 1LM

C220 M6 and C240 M6

Memory Bandwidth Boost

Enabled

Enabled, Disabled

C220 M6 and C240 M6

CR FastGo Config

Auto

Auto, Default, Option 1, Option 2, Option 3, Option 4, Option 5, Enable Optimization, Disable Optimization

C220 M6 and C240 M6

Memory Refresh Rate

2x Refresh

1x Refresh, 2x Refresh

C220 M6 and C240 M6

Console redirection

Disabled

Disabled, COM0, COM1 or serial-port-b

C220 M6 and C240 M6

BIOS Tokens for B200 M6 in 4.2(1d)

Name

Default Value

Server Supported Values

Platform

Dependencies

Core Multi Processing

All

All, 1 to 48

B200 M6

CR QoS

Mode 0 - Disable the PMem QoS Feature

Recipe 1, Recipe 2, Recipe 3, Disabled, Mode 0 - Disable the PMem QoS Feature, Mode 1 - M2M QoS Enable ;CHA QoS Disable, Mode 2 - M2M QoS Enable;CHA QoS Enable

B200 M6

IIO eDPC Support

OnFatal and Non-Fatal Errors

On Fatal Error, Disabled, OnFatal and Non-Fatal Errors

B200 M6

Multikey Total Memory Encryption (MK-TME)

Disabled

Enabled, Disabled

B200 M6

SW Guard Extensions (SGX)

Disabled

Enabled, Disabled

B200 M6

Total Memory Encryption (TME)

Disabled

Enabled, Disabled

B200 M6

Select Owner EPOCH input type

Manual User Defined Owner EPOCHs

SGX Owner EPOCH activated, Change to New Random Owner EPOCHs, Manual User Defined Owner EPOCHs

B200 M6

UPI Prefetch

Auto

Auto, Enabled, Disabled

B200 M6

Partial Cache Line Sparing

Enabled

Enabled, Disabled

B200 M6

Select PPR type configuration

Hard PPR

Hard PPR, Soft PPR, Disabled

B200 M6

SGX Auto MP Registration Agent

Disabled

Enabled, Disabled

B200 M6

SProcessor Epochn

0

n

B200 M6

SGX Factory Reset

Disabled

Enabled, Disabled

B200 M6

SGX PUBKEY HASHn

0

SGX PUBKEY HASH0-Between 7-0, SGX PUBKEY HASH1-Between 15-8, SGX PUBKEY HASH2-Between 23-16, SGX PUBKEY HASH3-Between 31-24

B200 M6

SGX Write Enable

Enabled

Enabled, Disabled

B200 M6

SGX Pkg info In-Band Access

Disabled

Enabled, Disabled

B200 M6

SGX QoS

Enabled

Enabled, Disabled

B200 M6

Enhanced Memory Test

Auto

Auto, Disabled, Enabled

B200 M6

Intel Dynamic Speed Select

Disabled

Enabled, Disabled

B200 M6

Intel Speed Select

Base

Base, Config 1, Config 2, Config 3, Config 4

B200 M6

UPI Link Frequency Select

Auto

9.6GT/s, 10.4GT/s, 11.2GT/s, Auto, Use Per Link Setting

B200 M6

UMA Clustering

Hemisphere(2-clusters)

Hemisphere(2-clusters), Disable(All-2-All)

B200 M6

eADR Support

Disabled

Auto, Enabled, Disabled

B200 M6

Volatile Memory Mode

2LM

2LM, 1LM

B200 M6

Memory Bandwidth Boost

Enabled

Enabled, Disabled

B200 M6

CR FastGo Config

Auto

Auto, Default, Option 1, Option 2, Option 3, Option 4, Option 5, Enable Optimization, Disable Optimization

B200 M6

Memory Refresh Rate

2x Refresh

1x Refresh, 2x Refresh

B200 M6

Console redirection

Disabled

Disabled, COM0, COM1 or serial-port-b

B200 M6

Terminal type

VT100

PC-ANSI, VT100, VT100-PLUS, VT-UTF8

B200 M6

TPM Support

Enabled

Enabled, Disabled

B200 M6

TPM Pending operation

None

None, TpmClear

B200 M6

SHA-1 PCR Bank

Enabled

Enabled, Disabled

B200 M6

SHA256 PCR Bank

Enabled

Enabled, Disabled

B200 M6

Flow Control

None

None, RTS-CTS

B200 M6

Baud rate

115.2k

9.6k, 9.2k, 38.4k, 57.6k, 115.2k

B200 M6

OS Boot Watchdog Timer

Enabled

Enabled, Disabled

B200 M6

OS Boot Watchdog Timer Timeout

10 minutes

5 minutes, 10 minutes, 15 minutes, 20 minutes

B200 M6

OS Boot Watchdog Timer Policy

Power Off

Power Off, Reset

B200 M6

Intel VT for directed IO

Enabled

Enabled, Disabled

B200 M6

Intel VTD coherency support

Disabled

Enabled, Disabled

B200 M6

Intel Trusted Execution Technology Support

Disabled

Enabled, Disabled

B200 M6

Intel Virtualization Technology

Enabled

Enabled, Disabled

B200 M6

Legacy USB Support

Enabled

Enabled, Disabled, Auto

B200 M6

New and Changed BIOS Tokens for M5 servers in 4.2(1d)

Name

Default Value

Server Supported Values

Platform

Dependencies

New/Changed

MRAID Link Speed

Auto

Auto, Disabled, Enabled, GEN1, GEN2, GEN3,GEN4

C220 M5 and C240 M5

Changed

RAID-n Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C480 M5

Changed

PCIe Slot MRAID-n OptionROM

Enabled

Enabled, Disabled

C220 M5 and C240 M5

Changed

Front NVMEn Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C220 M5 and C240 M5

Changed

PCIe Slot n Link Speed

Auto

Auto, Disabled, GEN1,GEN2, GEN3, GEN4

C220 M5, C240 M5, C480 M5, and C125 M5

Changed

Rear NVMEn Link Speed

Auto

Auto, Disabled, Enabled, GEN1,GEN2, GEN3, GEN4

C240 M5

Changed

Select Memory RAS Configuration

ADDDC Sparing

Maximum-performance, Mirror-mode-1lm, ADDDC Sparing, Partial-mirror-mode-1lm

C240 M5

Changed

Turbo Mode

Enabled

Enabled, Disabled

C240 M5

Changed

EIST PSD Function

HW all

HW all, SW all

C240 M5

Changed

Uncore Frequency Scaling

Enabled

Enabled, Disabled

C240 M5

Changed

SpeedStep (Pstates)

Enabled

Enabled, Disabled

C240 M5

Changed