Viewing Server Properties
This chapter includes the following sections:
- Viewing Server Properties
- Viewing CPU Properties
- Viewing Memory Properties
- Viewing Power Supply Properties
- Viewing Storage Properties
- Viewing PCI Adapter Properties
- Viewing Power Policy Statistics
- Viewing Hard Drive Presence
Viewing Server Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters chassis command mode. |
| Step 2 | Server /chassis # show detail | Displays server properties. |
This example displays server properties:
Server# scope chassis
Server /chassis # show detail
Chassis:
Power: on
Power Button: unlocked
IOS Lockout: unlocked
Serial Number: FOC16161F1P
Product Name: E160D
PID : UCS-E160D-M1/K9
UUID: 1255F7F0-9F17-0000-E312-94B74999D9E7
Description
Viewing CPU Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters chassis command mode. |
| Step 2 | Server /chassis # show cpu [detail] | Displays CPU properties. |
This example displays CPU properties:
Server# scope chassis Server /chassis # show cpu Name Cores Version ------------ -------- -------------------------------------------------- CPU1 4 Intel(R) Xeon(R) CPU E5-2418L 0 @ 2.00GHz Server /chassis #
Viewing Memory Properties
The server must be powered on, or the properties will not display.
This example displays memory properties:
Server# scope chassis Server /chassis # show dimm Name Capacity Channel Speed (MHz) Channel Type -------------------- --------------- ------------------- --------------- Node0_Dimm0 8192 MB 1333 DDR3 Node0_Dimm1 8192 MB 1333 DDR3 Node0_Dimm2 8192 MB 1333 DDR3
This example displays detailed information about memory properties:
Server# scope chassis Server /chassis # show dimm detail Name Node0_Dimm0: Capacity: 8192 MB Channel Speed (MHz): 1333 Channel Type: DDR3 Memory Type Detail: Registered (Buffered) Bank Locator: Node0_Bank0 Visibility: Yes Operability: Operable Manufacturer: Samsung Part Number: M393B1K70DH0- Serial Number: 86A7D514 Asset Tag: Dimm0_AssetTag Data Width: 64 bits Name Node0_Dimm1: Capacity: 8192 MB
This example displays DIMM summary information:
Server# scope chassis Server /chassis # show dimm-summary DIMM Summary: Memory Speed: 1334 MHz Total Memory: 24576 MB Effective Memory: 24576 MB Redundant Memory: 0 MB Failed Memory: 0 MB Ignored Memory: 0 MB Number of Ignored Dimms: 0 Number of Failed Dimms: 0 Memory RAS possible: Reserved Memory Configuration: Maximum Performance
Viewing Power Supply Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope power-cap | Enters the power cap command mode. |
| Step 2 | Server /power-cap # show [detail] | Displays the server power consumption information. |
This example displays the detailed power supply properties for a single-wide E-Series Server:
Server# scope power-cap Server /power-cap # show detail Cur Consumption (W): 36.10 W Max Consumption (W): 075 Min Consumption (W): 36.10 W Server /power-cap #
This example displays the detailed power supply properties for a double-wide E-Series Server:
Server# scope power-cap Server /power-cap # show detail Cur Consumption (W): 43.1 W Max Consumption (W): 160 Min Consumption (W): 43.1 W Server /power-cap #
Viewing Storage Properties
Viewing Storage Adapter Properties
The server must be powered on, or the properties will not display.
This example displays storage properties:
Server# scope chassis
Server /chassis # show storageadapter
Controller Product Name Firmware Package Build Product ID Cache Memory Size
---------- --------------------------- ---------------------- -------------- -----------------
SLOT-5 LSI MegaRAID SAS 2004 ROMB 20.10.1-0092 LSI Logic 0 MB
Viewing Physical Drive Properties
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # scope storageadapter SLOT-slot-number | Enters command mode for an installed storage card. |
| Step 3 | Server /chassis/storageadapter # show physical-drive [slot-number] [detail] | Displays physical drive information for the storage card. |
| Step 4 | Server /chassis/storageadapter # show physical-drive-count [detail] | Displays the number of physical drives on the storage card. |
| Step 5 | Server /chassis/storageadapter # scope physical-drive slot-number | Enters command mode for the specified physical drive. |
| Step 6 | Server /chassis/storageadapter/physical-drive # show general [detail] | Displays general information about the specified physical drive. |
| Step 7 | Server /chassis/storageadapter/physical-drive # show security [detail] | Displays inquiry data about the specified physical drive. |
| Step 8 | Server /chassis/storageadapter/physical-drive # show status [detail] | Displays status information about the specified physical drive. |
This example displays general information about the physical drive number 1 on the storage card named SLOT-5:
Server# scope chassis
Server /chassis # scope storageadapter SLOT-5
Server /chassis/storageadapter # scope physical-drive 1
Server /chassis/storageadapter/physical-drive # show general
Slot Number 1:
Controller: SLOT-5
Enclosure Device ID: 64
Device ID: 3
Sequence Number: 2
Media Error Count: 0
Other Error Count: 12
Predictive Failure Count: 0
Link Speed: 6.0 Gb/s
Interface Type: SATA
Media Type: HDD
Block Size: 512
Block Count: 1953525168
Raw Size: 953869 MB
Non Coerced Size: 953357 MB
Coerced Size: 952720 MB
SAS Address 0: 4433221100000000
SAS Address 1:
Connected Port 0:
Connected Port 1:
Connected Port 2:
Connected Port 3:
Connected Port 4:
This example provides status information about the physical drive number 1 on the storage card named SLOT-5:
Server# scope chassis Server /chassis # scope storageadapter SLOT-5 Server /chassis/storageadapter # scope physical-drive 1 Server /chassis/storageadapter/physical-drive # show status Slot Number 1: Controller: SLOT-5 State: system Online: true Fault: false
Viewing Virtual Drive Properties
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # scope storageadapter SLOT-slot-number | Enters command mode for an installed storage card. |
| Step 3 | Server /chassis/storageadapter # show virtual-drive [drive-number] [detail] | Displays virtual drive information for the storage card. |
| Step 4 | Server /chassis/storageadapter # show virtual-drive-count [detail] | Displays the number of virtual drives configured on the storage card. |
| Step 5 | Server /chassis/storageadapter # scope virtual-drive drive-number | Enters command mode for the specified virtual drive. |
| Step 6 | Server /chassis/storageadapter/virtual-drive # show physical-drive [detail] | Displays physical drive information about the specified virtual drive. |
This example displays power supply properties:
Server# scope chassis Server /chassis # scope storageadapter SLOT-5 Server /chassis/storageadapter # show virtual-drive Virtual Drive Status Name Size RAID Level -------------- -------------------- ------------------------ ---------- ---------- 0 Optimal 571250 MB RAID 1 Server /chassis/storageadapter # show virtual-drive-count PCI Slot SLOT-5: Virtual Drive Count: 1 Degraded Virtual Drive Count: 0 Offline Virtual Drive Count: 0 Server /chassis/storageadapter # scope virtual-drive 0 Server /chassis/storageadapter/virtual-drive # show physical-drive Span Physical Drive Status Starting Block Number Of Blocks ----- -------------- ---------- -------------- ---------------- 0 2 online 0 1169920000 0 1 online 0 1169920000
Viewing PCI Adapter Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # show pci-adapter [detail] | Displays PCI adapter properties. |
This example displays PCI adapter properties:
Server# scope chassis Server /chassis # show pci-adapter Name Slot Vendor ID Device ID Product Name ---------------- ----- ------------ ------------ ------------------------- PCIe Adapter1 1 0x1137 0x0042 Cisco UCS P81E Virtual... PCIe Adapter2 5 0x1077 0x2432 Qlogic QLE2462 4Gb dua... Server /chassis #
Viewing Power Policy Statistics
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# show power-cap detail | Displays the server power consumption statistics and the power cap policy. |
The displayed fields are described in the following table:
| Name | Description |
|---|---|
| Current Consumption |
The power currently being used by the server, in watts. |
| Maximum Consumption |
The maximum number of watts consumed by the server since the last time it was rebooted. |
| Minimum Consumption |
The minimum number of watts consumed by the server since the last time it was rebooted. |
This example displays the detailed power statistics for a single-wide E-Series Server:
Server# scope power-cap Server /power-cap # show detail Cur Consumption (W): 36.10 W Max Consumption (W): 075 Min Consumption (W): 36.10 W Server /power-cap #
This example displays the detailed power statistics for a double-wide E-Series Server:
Server# scope power-cap Server /power-cap # show detail Cur Consumption (W): 43.1 W Max Consumption (W): 160 Min Consumption (W): 43.1 W Server /power-cap #
Viewing Hard Drive Presence
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # show hdd | Displays the hard drives. |
This example displays power supply properties:
Server# scope chassis Server /chassis # show hdd Name Status -------------------- -------------------- HDD1_PRS inserted HDD2_PRS inserted HDD3_PRS inserted
Feedback