Viewing Server Properties

This chapter includes the following sections:

Viewing Server Properties

Before You Begin

The server must be powered on, or the properties will not display.

Procedure
      Command or Action Purpose
    Step 1 Server# scope chassis  

    Enters chassis command mode.

     
    Step 2 Server /chassis # show detail  

    Displays server properties.

     

    This example displays server properties:

    Server# scope chassis
    Server /chassis # show detail
    Chassis:
        Power: on
        Power Button: unlocked
        IOS Lockout: unlocked
        Serial Number: FOC16161F1P
    				Product Name: E160D
    				PID : UCS-E160D-M1/K9
    				UUID: 1255F7F0-9F17-0000-E312-94B74999D9E7
    				Description
     
    

    Viewing CPU Properties

    Before You Begin

    The server must be powered on, or the properties will not display.

    Procedure
        Command or Action Purpose
      Step 1 Server# scope chassis  

      Enters chassis command mode.

       
      Step 2 Server /chassis # show cpu [detail]  

      Displays CPU properties.

       

      This example displays CPU properties:

      Server# scope chassis
      Server /chassis # show cpu
      Name         Cores    Version                                            
      ------------ -------- -------------------------------------------------- 
      CPU1         4        Intel(R) Xeon(R) CPU     E5-2418L 0 @ 2.00GHz     
      
      Server /chassis #  
      

      Viewing Memory Properties

      Before You Begin

      The server must be powered on, or the properties will not display.

      Procedure
          Command or Action Purpose
        Step 1 Server# scope chassis  

        Enters chassis command mode.

         
        Step 2 Server /chassis # show dimm [detail]  

        Displays memory properties.

         
        Step 3 Server /chassis # show dimm-summary  

        Displays DIMM summary information.

         

        This example displays memory properties:

        Server# scope chassis
        Server /chassis # show dimm
        Name         								Capacity        Channel Speed (MHz) Channel Type    
        -------------------- --------------- ------------------- --------------- 
        
        Node0_Dimm0 									8192 MB 								1333 															DDR3 
        Node0_Dimm1 									8192 MB 								1333 															DDR3 
        Node0_Dimm2 									8192 MB 								1333 															DDR3 
         
        

        This example displays detailed information about memory properties:

        Server# scope chassis
        Server /chassis # show dimm detail
        Name Node0_Dimm0:
        	Capacity: 8192 MB
        	Channel Speed (MHz): 1333
        	Channel Type: DDR3
        	Memory Type Detail: Registered (Buffered)
        	Bank Locator: Node0_Bank0
        	Visibility: Yes
        	Operability: Operable
        	Manufacturer: Samsung
        	Part Number: M393B1K70DH0-
        	Serial Number: 86A7D514
        	Asset Tag: Dimm0_AssetTag
        	Data Width: 64 bits
        	Name Node0_Dimm1:
        	Capacity: 8192 MB
        
        

        This example displays DIMM summary information:

        Server# scope chassis
        Server /chassis # show dimm-summary
        DIMM Summary:
        	Memory Speed: 1334 MHz
        	Total Memory: 24576 MB
        	Effective Memory: 24576 MB
        	Redundant Memory: 0 MB
        	Failed Memory: 0 MB
        	Ignored Memory: 0 MB
        	Number of Ignored Dimms: 0
        	Number of Failed Dimms: 0
        	Memory RAS possible: Reserved
        	Memory Configuration: Maximum Performance
        
        

        Viewing Power Supply Properties

        Before You Begin

        The server must be powered on, or the properties will not display.

        Procedure
            Command or Action Purpose
          Step 1 Server# scope power-cap  

          Enters the power cap command mode.

           
          Step 2 Server /power-cap # show [detail]  

          Displays the server power consumption information.

           

          This example displays the detailed power supply properties for a single-wide E-Series Server:

          		Server# scope power-cap
          		Server /power-cap # show detail
          			Cur Consumption (W): 36.10 W
          			Max Consumption (W): 075
          			Min Consumption (W): 36.10 W
          	Server /power-cap #  
          
          

          This example displays the detailed power supply properties for a double-wide E-Series Server:

          		Server# scope power-cap
          		Server /power-cap # show detail
          			Cur Consumption (W): 43.1 W
          			Max Consumption (W): 160
          			Min Consumption (W): 43.1 W
          	Server /power-cap #
            
          

          Viewing Storage Properties

          Viewing Storage Adapter Properties

          Before You Begin

          The server must be powered on, or the properties will not display.

          Procedure
              Command or Action Purpose
            Step 1 Server# scope chassis  

            Enters the chassis command mode.

             
            Step 2 Server /chassis # show storageadapter [slot] [detail]  

            Displays installed storage cards.

            Note   

            This command displays all MegaRAID controllers on the server that can be managed through CIMC. If an installed controller or storage device is not displayed, then it cannot be managed through CIMC.

             
            Step 3 Server /chassis # scope storageadapter SLOT-slot-number  

            Enters command mode for an installed storage card.

             
            Step 4 Server /chassis/storageadapter # show capabilites [detail]  

            Displays RAID levels supported by the storage card.

             
            Step 5 Server /chassis/storageadapter # show error-counters [detail]  

            Displays number of errors seen by the storage card.

             
            Step 6 Server /chassis/storageadapter # show firmware-versions [detail]  

            Displays firmware version information for the storage card.

             
            Step 7 Server /chassis/storageadapter # show hw-config [detail]  

            Displays hardware information for the storage card.

             
            Step 8 Server /chassis/storageadapter # show pci-info [detail]  

            Displays adapter PCI information for the storage card.

             
            Step 9 Server /chassis/storageadapter # show running-firmware-images [detail]  

            Displays running firmware information for the storage card.

             
            Step 10 Server /chassis/storageadapter # show settings [detail]  

            Displays adapter firmware settings for the storage card.

             

            This example displays storage properties:

            Server# scope chassis
            Server /chassis # show storageadapter
            
            Controller Product Name                Firmware Package Build Product ID     Cache Memory Size 
            ---------- --------------------------- ---------------------- -------------- ----------------- 
            SLOT-5     LSI MegaRAID SAS 2004 ROMB  20.10.1-0092           LSI Logic      0 MB           
            
                        
            

            Viewing Physical Drive Properties

            Procedure
                Command or Action Purpose
              Step 1 Server# scope chassis  

              Enters the chassis command mode.

               
              Step 2 Server /chassis # scope storageadapter SLOT-slot-number  

              Enters command mode for an installed storage card.

               
              Step 3 Server /chassis/storageadapter # show physical-drive [slot-number] [detail]  

              Displays physical drive information for the storage card.

               
              Step 4 Server /chassis/storageadapter # show physical-drive-count [detail]  

              Displays the number of physical drives on the storage card.

               
              Step 5 Server /chassis/storageadapter # scope physical-drive slot-number  

              Enters command mode for the specified physical drive.

               
              Step 6 Server /chassis/storageadapter/physical-drive # show general [detail]  

              Displays general information about the specified physical drive.

               
              Step 7 Server /chassis/storageadapter/physical-drive # show security [detail]  

              Displays inquiry data about the specified physical drive.

               
              Step 8 Server /chassis/storageadapter/physical-drive # show status [detail]  

              Displays status information about the specified physical drive.

               

              This example displays general information about the physical drive number 1 on the storage card named SLOT-5:

              Server# scope chassis
              Server /chassis # scope storageadapter SLOT-5
              Server /chassis/storageadapter # scope physical-drive 1
              Server /chassis/storageadapter/physical-drive # show general
              Slot Number 1:
                  Controller: SLOT-5
              				Enclosure Device ID: 64
              				Device ID: 3
              				Sequence Number: 2
              				Media Error Count: 0
              				Other Error Count: 12
              				Predictive Failure Count: 0
              				Link Speed: 6.0 Gb/s
              				Interface Type: SATA
              				Media Type: HDD
              				Block Size: 512
              				Block Count: 1953525168
              				Raw Size: 953869 MB
              				Non Coerced Size: 953357 MB
              				Coerced Size: 952720 MB
              				SAS Address 0: 4433221100000000
              				SAS Address 1: 
              				Connected Port 0: 
              				Connected Port 1: 
              				Connected Port 2: 
              				Connected Port 3: 
              				Connected Port 4: 
                           
              

              This example provides status information about the physical drive number 1 on the storage card named SLOT-5:

              Server# scope chassis
              Server /chassis # scope storageadapter SLOT-5
              Server /chassis/storageadapter # scope physical-drive 1
              Server /chassis/storageadapter/physical-drive # show status
              Slot Number 1:
              			Controller: SLOT-5
              			State: system
              			Online: true
              			Fault: false
              

              Viewing Virtual Drive Properties

              Procedure
                  Command or Action Purpose
                Step 1 Server# scope chassis  

                Enters the chassis command mode.

                 
                Step 2 Server /chassis # scope storageadapter SLOT-slot-number  

                Enters command mode for an installed storage card.

                 
                Step 3 Server /chassis/storageadapter # show virtual-drive [drive-number] [detail]  

                Displays virtual drive information for the storage card.

                 
                Step 4 Server /chassis/storageadapter # show virtual-drive-count [detail]  

                Displays the number of virtual drives configured on the storage card.

                 
                Step 5 Server /chassis/storageadapter # scope virtual-drive drive-number  

                Enters command mode for the specified virtual drive.

                 
                Step 6 Server /chassis/storageadapter/virtual-drive # show physical-drive [detail]  

                Displays physical drive information about the specified virtual drive.

                 

                This example displays power supply properties:

                Server# scope chassis
                Server /chassis # scope storageadapter SLOT-5
                Server /chassis/storageadapter # show virtual-drive
                Virtual Drive  Status               Name                     Size       RAID Level 
                -------------- -------------------- ------------------------ ---------- ---------- 
                0              Optimal                                       571250 MB  RAID 1     
                
                Server /chassis/storageadapter # show virtual-drive-count
                PCI Slot SLOT-5:
                    Virtual Drive Count: 1
                    Degraded Virtual Drive Count: 0
                    Offline Virtual Drive Count: 0
                Server /chassis/storageadapter # scope virtual-drive 0
                Server /chassis/storageadapter/virtual-drive # show physical-drive 
                Span  Physical Drive Status     Starting Block Number Of Blocks 
                ----- -------------- ---------- -------------- ---------------- 
                0     2              online     0              1169920000       
                0     1              online     0              1169920000       
                
                 
                

                Viewing PCI Adapter Properties

                Before You Begin

                The server must be powered on, or the properties will not display.

                Procedure
                    Command or Action Purpose
                  Step 1 Server# scope chassis  

                  Enters the chassis command mode.

                   
                  Step 2 Server /chassis # show pci-adapter [detail]  

                  Displays PCI adapter properties.

                   

                  This example displays PCI adapter properties:

                  Server# scope chassis
                  Server /chassis # show pci-adapter
                  Name             Slot  Vendor ID    Device ID    Product Name              
                  ---------------- ----- ------------ ------------ ------------------------- 
                  PCIe Adapter1    1     0x1137       0x0042       Cisco UCS P81E Virtual... 
                  PCIe Adapter2    5     0x1077       0x2432       Qlogic QLE2462 4Gb dua... 
                  
                  Server /chassis # 
                  

                  Viewing Power Policy Statistics

                  Procedure
                      Command or Action Purpose
                    Step 1 Server# show power-cap detail 

                    Displays the server power consumption statistics and the power cap policy.

                     

                    The displayed fields are described in the following table:

                    Name Description

                    Current Consumption

                    The power currently being used by the server, in watts.

                    Maximum Consumption

                    The maximum number of watts consumed by the server since the last time it was rebooted.

                    Minimum Consumption

                    The minimum number of watts consumed by the server since the last time it was rebooted.

                    This example displays the detailed power statistics for a single-wide E-Series Server:

                    		Server# scope power-cap
                    		Server /power-cap # show detail
                    			Cur Consumption (W): 36.10 W
                    			Max Consumption (W): 075
                    			Min Consumption (W): 36.10 W
                    	Server /power-cap #  
                    
                    

                    This example displays the detailed power statistics for a double-wide E-Series Server:

                    		Server# scope power-cap
                    		Server /power-cap # show detail
                    			Cur Consumption (W): 43.1 W
                    			Max Consumption (W): 160
                    			Min Consumption (W): 43.1 W
                    	Server /power-cap #
                      
                    

                    Viewing Hard Drive Presence

                    Before You Begin

                    The server must be powered on, or the properties will not display.

                    Procedure
                        Command or Action Purpose
                      Step 1 Server# scope chassis  

                      Enters the chassis command mode.

                       
                      Step 2 Server /chassis # show hdd  

                      Displays the hard drives.

                       

                      This example displays power supply properties:

                      Server# scope chassis
                      Server /chassis # show hdd
                      				Name 												Status 
                      -------------------- -------------------- 
                      HDD1_PRS 												inserted 
                      HDD2_PRS 												inserted 
                      HDD3_PRS 												inserted