This example shows a sample output of the show environment status command when a power supply with serial number starting with QCS is installed on the C9500-32C switch. In this example, the
second fan displays the state as N/A because the power supply with serial number starting with QCS has a single fan.
Device# show inventory
NAME: "Chassis", DESCR: "Cisco Catalyst 9500 Series Chassis"
PID: C9500-32C , VID: V00 , SN: CAT2202L2M5
NAME: "Power Supply Module 1", DESCR: "Cisco Catalyst 9500 Series 1600W AC Power Supply"
PID: C9K-PWR-1600WAC-R , VID: V01 , SN: QCS2230500J
Device# show environment status
Power Fan States
Supply Model No Type Capacity Status 0 1
------ -------------------- ---- -------- --------- -----------
PS1 C9K-PWR-1600WAC-R AC 1600 W ok good N/A
This example shows a sample output of the show environment status command when a power supply with serial number starting with POG is installed on the C9500-32C switch. In this example, the
second fan displays the state as good because the power supply with serial number starting with POG has a two fans.
Device# show inventory
NAME: "Chassis", DESCR: "Cisco Catalyst 9500 Series Chassis"
PID: C9500-32C , VID: V01 , SN: CAT2344L1N8
NAME: "Power Supply Module 0", DESCR: "Cisco Catalyst 9500 Series 1600W AC Power Supply"
PID: C9K-PWR-1600WAC-R , VID: V01 , SN: POG2319D04K
Device# show environment status
Power Fan States
Supply Model No Type Capacity Status 0 1
------ -------------------- ---- -------- --------- -----------
PS0 C9K-PWR-1600WAC-R AC 1600 W ok good good
This example shows a sample output of the show power detail command when a power supply with serial number starting with QCS is installed on the C9500X-60L4D switch.
Device# show power detail
Power Fan States
Supply Model No Type Capacity Status 0 1
------ -------------------- ---- -------- --------- -----------
PS1 C9K-PWR-1500WAC AC 1500 W active good n.a
PS2 C9K-PWR-1500WAC AC 1500 W active good n.a
Fan Fan states
Tray Status 0 1
------ ----- ------------
FT1 active good good
FT2 active good good
FT3 active good good
FT4 active good good
FT5 active good good
FT6 active good good
This example shows how to set the power supply in slot A to off:
Device# power supply 1 slot A off
Disabling Power supply A may result in a power loss to PoE devices and/or switches ... Continue? (yes/[no]): yes
Device#
Jun 10 04:52:54.389: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 powered off
Jun 10 04:52:56.717: %PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present
Device#
This example shows how to set the power supply in slot A to on:
Device# power supply 1 slot A on
Jun 10 04:54:39.600: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 powered on
This example shows the output of the show env power command:
Table 2. show env power Status Descriptions
Field |
Description |
OK
|
The power supply is present and power is good.
|
Not Present
|
No power supply is installed.
|
No Input Power
|
The power supply is present but there is no input power.
|
Disabled
|
The power supply and input power are present, but power supply is switched off by CLI.
|
Not Responding
|
The power supply is not recognizable or is faulty.
|
Failure-Fan
|
The power supply fan is faulty.
|