- Index
- Preface
- Using the Command Line Interface
- Catalyst 2960 Switch Cisco IOS Commands - aaa accounting through rcommand
- Catalyst 2960 Switch Cisco IOS Commands - rmon collection through show vtp
- Catalyst 2960 Switch Cisco IOS Commands - shutdown through vtp
- Catalyst 2960 Switch Bootloader Commands
- Catalyst 2960 Switch Debug Commands
- Catalyst 2960 Switch Show Platform Commands
- shutdown
- shutdown vlan
- snmp-server enable traps
- snmp-server host
- snmp trap mac-notification
- spanning-tree backbonefast
- spanning-tree bpdufilter
- spanning-tree bpduguard
- spanning-tree cost
- spanning-tree etherchannel guard misconfig
- spanning-tree extend system-id
- spanning-tree guard
- spanning-tree link-type
- spanning-tree loopguard default
- spanning-tree mode
- spanning-tree mst configuration
- spanning-tree mst cost
- spanning-tree mst forward-time
- spanning-tree mst hello-time
- spanning-tree mst max-age
- spanning-tree mst max-hops
- spanning-tree mst port-priority
- spanning-tree mst pre-standard
- spanning-tree mst priority
- spanning-tree mst root
- spanning-tree port-priority
- spanning-tree portfast (global configuration)
- spanning-tree portfast (interface configuration)
- spanning-tree transmit hold-count
- spanning-tree uplinkfast
- spanning-tree vlan
- speed
- storm-control
- switchport access
- switchport block
- switchport host
- switchport mode
- switchport nonegotiate
- switchport port-security
- switchport port-security aging
- switchport protected
- switchport trunk
- switchport voice detect
- switchport voice vlan
- system mtu
- test cable-diagnostics tdr
- traceroute mac
- traceroute mac ip
- trust
- udld
- udld port
- udld reset
- vlan (global configuration)
- vlan (VLAN configuration)
- vlan database
- vmps reconfirm (privileged EXEC)
- vmps reconfirm (global configuration)
- vmps retry
- vmps server
- vtp (global configuration)
- vtp (VLAN configuration)
shutdown
Use the shutdown interface configuration command to disable an interface. Use the no form of this command to restart a disabled interface.
shutdown
no shutdown
Syntax Description
This command has no arguments or keywords.
Defaults
The port is enabled (not shut down).
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The shutdown command causes a port to stop forwarding. You can enable the port with the no shutdown command.
The no shutdown command has no effect if the port is a static-access port assigned to a VLAN that has been deleted, suspended, or shut down. The port must first be a member of an active VLAN before it can be re-enabled.
The shutdown command disables all functions on the specified interface.
This command also marks the interface as unavailable. To see if an interface is disabled, use the show interfaces privileged EXEC command. An interface that has been shut down is shown as administratively down in the display.
Examples
These examples show how to disable and re-enable a port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# shutdown
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# no shutdown
You can verify your settings by entering the show interfaces privileged EXEC command.
Related Commands
|
|
---|---|
Displays the statistical information specific to all interfaces or to a specific interface. |
shutdown vlan
Use the shutdown vlan global configuration command to shut down (suspend) local traffic on the specified VLAN. Use the no form of this command to restart local traffic on the VLAN.
shutdown vlan vlan-id
no shutdown vlan vlan-id
Syntax Description
Defaults
No default is defined.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The shutdown vlan command does not change the VLAN information in the VTP database. The command shuts down local traffic, but the switch still advertises VTP information.
Examples
This example shows how to shut down traffic on VLAN 2:
Switch(config)# shutdown vlan 2
You can verify your setting by entering the show vlan privileged EXEC command.
Related Commands
snmp-server enable traps
Use the snmp-server enable traps global configuration command to enable the switch to send Simple Network Management Protocol (SNMP) notifications for various traps or inform requests to the network management system (NMS). Use the no form of this command to return to the default setting.
snmp-server enable traps [bridge [newroot] [topologychange] | cluster | config | copy-config | entity | envmon [fan | shutdown | status | supply | temperature] | errdisable [notification-rate value] | flash | hsrp | ipmulticast | mac-notification | msdp | ospf [cisco-specific | errors | lsa | rate-limit | retransmit | state-change] | pim [invalid-pim-message | neighbor-change | rp-mapping-change] | port-security [trap-rate value] | rtr | snmp [authentication | coldstart | linkdown | linkup | warmstart] | storm-control trap-rate value | stpx [inconsistency] [root-inconsistency] [loop-inconsistency] | syslog | tty | vlan-membership | vlancreate | vlandelete | vtp]
no snmp-server enable traps [bridge [newroot] [topologychange] | cluster | config | copy-config | entity | envmon [fan | shutdown | status | supply | temperature] | errdisable [notification-rate] | flash | hsrp | ipmulticast | mac-notification | msdp | ospf [cisco-specific | errors | lsa | rate-limit | retransmit | state-change] | pim [invalid-pim-message | neighbor-change | rp-mapping-change] | port-security [trap-rate] | rtr | snmp [authentication | coldstart | linkdown | linkup | warmstart] | storm-control trap-rate | stpx [inconsistency] [root-inconsistency] [loop-inconsistency] | syslog | tty | vlan-membership | vlancreate | vlandelete | vtp]
Syntax Description
Note Though visible in the command-line help strings, the cpu [threshold], insertion, and removal keywords are not supported. The snmp-server enable informs global configuration command is not supported. To enable the sending of SNMP inform notifications, use the snmp-server enable traps global configuration command combined with the snmp-server host host-addr informs global configuration command.
Defaults
The sending of SNMP traps is disabled.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Specify the host (NMS) that receives the traps by using the snmp-server host global configuration command. If no trap types are specified, all trap types are sent.
When supported, use the snmp-server enable traps command to enable sending of traps or informs.
Note Informs are not supported in SNMPv1.
To enable more than one type of trap, you must enter a separate snmp-server enable traps command for each trap type.
Examples
This example shows how to send VTP traps to the NMS:
Switch(config)# snmp-server enable traps vtp
You can verify your setting by entering the show vtp status or the show running-config privileged EXEC command.
Related Commands
snmp-server host
Use the snmp-server host global configuration command to specify the recipient (host) of a Simple Network Management Protocol (SNMP) notification operation. Use the no form of this command to remove the specified host.
snmp-server host host-addr [informs | traps] [version {1 | 2c | 3 {auth | noauth| priv}] [vrf vrf-instance] {community-string [notification-type]}
no snmp-server host host-addr [informs | traps] [version {1 | 2c | 3 {auth | noauth | priv}] [vrf vrf-instance] community-string
Syntax Description
Defaults
This command is disabled by default. No notifications are sent.
If you enter this command with no keywords, the default is to send all trap types to the host. No informs are sent to this host.
If no version keyword is present, the default is Version 1.
If Version 3 is selected and no authentication keyword is entered, the default is the noauth (noAuthNoPriv) security level.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
SNMP notifications can be sent as traps or inform requests. Traps are unreliable because the receiver does not send acknowledgments when it receives traps. The sender cannot determine if the traps were received. However, an SNMP entity that receives an inform request acknowledges the message with an SNMP response PDU. If the sender never receives the response, the inform request can be sent again. Thus, informs are more likely to reach their intended destinations.
However, informs consume more resources in the agent and in the network. Unlike a trap, which is discarded as soon as it is sent, an inform request must be held in memory until a response is received or the request times out. Traps are also sent only once, but an inform might be retried several times. The retries increase traffic and contribute to a higher overhead on the network.
If you do not enter an snmp-server host command, no notifications are sent. To configure the switch to send SNMP notifications, you must enter at least one snmp-server host command. If you enter the command with no keywords, all trap types are enabled for the host. To enable multiple hosts, you must enter a separate snmp-server host command for each host. You can specify multiple notification types in the command for each host.
If a local user is not associated with a remote host, the switch does not send informs for the auth (authNoPriv) and the priv (authPriv) authentication levels.
When multiple snmp-server host commands are given for the same host and kind of notification (trap or inform), each succeeding command overwrites the previous command. Only the last snmp-server host command is in effect. For example, if you enter an snmp-server host inform command for a host and then enter another snmp-server host inform command for the same host, the second command replaces the first.
The snmp-server host command is used with the snmp-server enable traps global configuration command. Use the snmp-server enable traps command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable traps command and the snmp-server host command for that host must be enabled. Some notification types cannot be controlled with the snmp-server enable traps command. For example, some notification types are always enabled. Other notification types are enabled by a different command.
The no snmp-server host command with no keywords disables traps, but not informs, to the host. To disable informs, use the no snmp-server host informs command.
Examples
This example shows how to configure a unique SNMP community string named comaccess for traps and prevent SNMP polling access with this string through access-list 10:
Switch(config)# snmp-server community comaccess ro 10
Switch(config)# snmp-server host 172.20.2.160 comaccess
Switch(config)# access-list 10 deny any
This example shows how to send the SNMP traps to the host specified by the name myhost.cisco.com. The community string is defined as comaccess:
Switch(config)# snmp-server enable traps
Switch(config)# snmp-server host myhost.cisco.com comaccess snmp
This example shows how to enable the switch to send all traps to the host myhost.cisco.com by using the community string public:
Switch(config)# snmp-server enable traps
Switch(config)# snmp-server host myhost.cisco.com public
You can verify your settings by entering the show running-config privileged EXEC command.
Related Commands
snmp trap mac-notification
Use the snmp trap mac-notification interface configuration command to enable the Simple Network Management Protocol (SNMP) MAC address notification trap on a specific Layer 2 interface. Use the no form of this command to return to the default setting.
snmp trap mac-notification {added | removed}
no snmp trap mac-notification {added | removed}
Syntax Description
added |
Enable the MAC notification trap whenever a MAC address is added on this interface. |
removed |
Enable the MAC notification trap whenever a MAC address is removed from this interface. |
Defaults
By default, the traps for both address addition and address removal are disabled.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Even though you enable the notification trap for a specific interface by using the snmp trap mac-notification command, the trap is generated only when you enable the snmp-server enable traps mac-notification and the mac address-table notification global configuration commands.
Examples
This example shows how to enable the MAC notification trap when a MAC address is added to a port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# snmp trap mac-notification added
You can verify your settings by entering the show mac address-table notification interface privileged EXEC command.
Related Commands
|
|
---|---|
clear mac address-table notification |
Clears the MAC address notification global counters. |
Enables the MAC address notification feature. |
|
Displays the MAC address notification settings for all interfaces or on the specified interface when the interface keyword is appended. |
|
Sends the SNMP MAC notification traps when the mac-notification keyword is appended. |
spanning-tree backbonefast
Use the spanning-tree backbonefast global configuration command to enable the BackboneFast feature. Use the no form of the command to return to the default setting.
spanning-tree backbonefast
no spanning-tree backbonefast
Syntax Description
This command has no arguments or keywords.
Defaults
BackboneFast is disabled.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can configure the BackboneFast feature for rapid PVST+ or for multiple spanning-tree (MST) mode, but the feature remains disabled (inactive) until you change the spanning-tree mode to PVST+.
BackboneFast starts when a root port or blocked port on a switch receives inferior BPDUs from its designated switch. An inferior BPDU identifies a switch that declares itself as both the root bridge and the designated switch. When a switch receives an inferior BPDU, it means that a link to which the switch is not directly connected (an indirect link) has failed (that is, the designated switch has lost its connection to the root switch. If there are alternate paths to the root switch, BackboneFast causes the maximum aging time on the interfaces on which it received the inferior BPDU to expire and allows a blocked port to move immediately to the listening state. BackboneFast then transitions the interface to the forwarding state. For more information, see the software configuration guide for this release.
Enable BackboneFast on all supported switches to allow the detection of indirect link failures and to start the spanning-tree reconfiguration sooner.
Examples
This example shows how to enable BackboneFast on the switch:
Switch(config)# spanning-tree backbonefast
You can verify your setting by entering the show spanning-tree summary privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree summary |
Displays a summary of the spanning-tree interface states. |
spanning-tree bpdufilter
Use the spanning-tree bpdufilter interface configuration command to prevent an interface from sending or receiving bridge protocol data units (BPDUs). Use the no form of this command to return to the default setting.
spanning-tree bpdufilter {disable | enable}
no spanning-tree bpdufilter
Syntax Description
disable |
Disable BPDU filtering on the specified interface. |
enable |
Enable BPDU filtering on the specified interface. |
Defaults
BPDU filtering is disabled.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can enable the BPDU filtering feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
You can globally enable BPDU filtering on all Port Fast-enabled interfaces by using the spanning-tree portfast bpdufilter default global configuration command.
You can use the spanning-tree bpdufilter interface configuration command to override the setting of the spanning-tree portfast bpdufilter default global configuration command.
Examples
This example shows how to enable the BPDU filtering feature on a port:
Switch(config)#
interface gigabitethernet0/1
Switch(config-if)# spanning-tree bpdufilter enable
You can verify your setting by entering the show running-config privileged EXEC command.
Related Commands
spanning-tree bpduguard
Use the spanning-tree bpduguard interface configuration command to put an interface in the error-disabled state when it receives a bridge protocol data unit (BPDU). Use the no form of this command to return to the default setting.
spanning-tree bpduguard {disable | enable}
no spanning-tree bpduguard
Syntax Description
disable |
Disable BPDU guard on the specified interface. |
enable |
Enable BPDU guard on the specified interface. |
Defaults
BPDU guard is disabled.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The BPDU guard feature provides a secure response to invalid configurations because you must manually put the interface back in service. Use the BPDU guard feature in a service-provider network to prevent an interface from being included in the spanning-tree topology.
You can enable the BPDU guard feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
You can globally enable BPDU guard on all Port Fast-enabled interfaces by using the spanning-tree portfast bpduguard default global configuration command.
You can use the spanning-tree bpduguard interface configuration command to override the setting of the spanning-tree portfast bpduguard default global configuration command.
Examples
This example shows how to enable the BPDU guard feature on a port:
Switch(config)#
interface gigabitethernet0/1
Switch(config-if)# spanning-tree bpduguard enable
You can verify your setting by entering the show running-config privileged EXEC command.
Related Commands
spanning-tree cost
Use the spanning-tree cost interface configuration command to set the path cost for spanning-tree calculations. If a loop occurs, spanning tree considers the path cost when selecting an interface to place in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree [vlan vlan-id] cost cost
no spanning-tree [vlan vlan-id] cost
Syntax Description
Defaults
The default path cost is computed from the interface bandwidth setting. These are the IEEE default path cost values:
•1000 Mb/s—4
•100 Mb/s—19
•10 Mb/s—100
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
When you configure the cost, higher values represent higher costs.
If you configure an interface with both the spanning-tree vlan vlan-id cost cost command and the spanning-tree cost cost command, the spanning-tree vlan vlan-id cost cost command takes effect.
Examples
This example shows how to set the path cost to 250 on a port:
Switch(config)#
interface gigabitethernet0/1
Switch(config-if)# spanning-tree cost 250
This example shows how to set a path cost to 300 for VLANs 10, 12 to 15, and 20:
Switch(config-if)# spanning-tree vlan 10,12-15,20 cost 300
You can verify your settings by entering the show spanning-tree interface interface-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree interface interface-id |
Displays spanning-tree information for the specified interface. |
Configures an interface priority. |
|
spanning-tree vlan priority |
Sets the switch priority for the specified spanning-tree instance. |
spanning-tree etherchannel guard misconfig
Use the spanning-tree etherchannel guard misconfig global configuration command to display an error message when the switch detects an EtherChannel misconfiguration. Use the no form of this command to disable the feature.
spanning-tree etherchannel guard misconfig
no spanning-tree etherchannel guard misconfig
Syntax Description
This command has no arguments or keywords.
Defaults
EtherChannel guard is enabled on the switch.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
When the switch detects an EtherChannel misconfiguration, this error message appears:
PM-4-ERR_DISABLE: Channel-misconfig error detected on [chars], putting [chars] in err-disable state.
To show switch ports that are in the misconfigured EtherChannel, use the show interfaces status err-disabled privileged EXEC command. To verify the EtherChannel configuration on a remote device, use the show etherchannel summary privileged EXEC command on the remote device.
When a port is in the error-disabled state because of an EtherChannel misconfiguration, you can bring it out of this state by entering the errdisable recovery cause channel-misconfig global configuration command, or you can manually re-enable it by entering the shutdown and no shut down interface configuration commands.
Examples
This example shows how to enable the EtherChannel guard misconfiguration feature:
Switch(config)# spanning-tree etherchannel guard misconfig
You can verify your settings by entering the show spanning-tree summary privileged EXEC command.
Related Commands
|
|
---|---|
errdisable recovery cause channel-misconfig |
Enables the timer to recover from the EtherChannel misconfiguration error-disabled state. |
show etherchannel summary |
Displays EtherChannel information for a channel as a one-line summary per channel-group. |
show interfaces status err-disabled |
Displays the interfaces in the error-disabled state. |
spanning-tree extend system-id
Use the spanning-tree extend system-id global configuration command to enable the extended system ID feature.
spanning-tree extend system-id
Note Though visible in the command-line help strings, the no version of this command is not supported. You cannot disable the extended system ID feature.
Syntax Description
This command has no arguments or keywords.
Defaults
The extended system ID is enabled.
Command Modes
Global configuration
Command History
|
|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The switch supports the IEEE 802.1t spanning-tree extensions. Some of the bits previously used for the switch priority are now used for the extended system ID (VLAN identifier for the per-VLAN spanning-tree plus [PVST+] and rapid PVST+ or as an instance identifier for the multiple spanning tree [MST]).
The spanning tree uses the extended system ID, the switch priority, and the allocated spanning-tree MAC address to make the bridge ID unique for each VLAN or multiple spanning-tree instance.
Support for the extended system ID affects how you manually configure the root switch, the secondary root switch, and the switch priority of a VLAN. For more information, see the "spanning-tree mst root" and the "spanning-tree vlan" sections.
If your network consists of switches that do not support the extended system ID and switches that do support it, it is unlikely that the switch with the extended system ID support will become the root switch. The extended system ID increases the switch priority value every time the VLAN number is greater than the priority of the connected switches.
Related Commands
|
|
---|---|
show spanning-tree summary |
Displays a summary of spanning-tree interface states. |
Configures the MST root switch priority and timers based on the network diameter. |
|
spanning-tree vlan priority |
Sets the switch priority for the specified spanning-tree instance. |
spanning-tree guard
Use the spanning-tree guard interface configuration command to enable root guard or loop guard on all the VLANs associated with the selected interface. Root guard restricts which interface is allowed to be the spanning-tree root port or the path-to-the root for the switch. Loop guard prevents alternate or root ports from becoming designated ports when a failure creates a unidirectional link. Use the no form of this command to return to the default setting.
spanning-tree guard {loop | none | root}
no spanning-tree guard
Syntax Description
loop |
Enable loop guard. |
none |
Disable root guard or loop guard. |
root |
Enable root guard. |
Defaults
Root guard is disabled.
Loop guard is configured according to the spanning-tree loopguard default global configuration command (globally disabled).
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can enable root guard or loop guard when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
When root guard is enabled, if spanning-tree calculations cause an interface to be selected as the root port, the interface transitions to the root-inconsistent (blocked) state to prevent the customer's switch from becoming the root switch or being in the path to the root. The root port provides the best path from the switch to the root switch.
When the no spanning-tree guard or the no spanning-tree guard none command is entered, root guard is disabled for all VLANs on the selected interface. If this interface is in the root-inconsistent (blocked) state, it automatically transitions to the listening state.
Do not enable root guard on interfaces that will be used by the UplinkFast feature. With UplinkFast, the backup interfaces (in the blocked state) replace the root port in the case of a failure. However, if root guard is also enabled, all the backup interfaces used by the UplinkFast feature are placed in the root-inconsistent state (blocked) and prevented from reaching the forwarding state. The UplinkFast feature is not available when the switch is operating in the rapid-PVST+ or MST mode.
Loop guard is most effective when it is configured on the entire switched network. When the switch is operating in PVST+ or rapid-PVST+ mode, loop guard prevents alternate and root ports from becoming designated ports, and spanning tree does not send bridge protocol data units (BPDUs) on root or alternate ports. When the switch is operating in MST mode, BPDUs are not sent on nonboundary interfaces if the interface is blocked by loop guard in all MST instances. On a boundary interface, loop guard blocks the interface in all MST instances.
To disable root guard or loop guard, use the spanning-tree guard none interface configuration command. You cannot enable both root guard and loop guard at the same time.
You can override the setting of the spanning-tree loopguard default global configuration command by using the spanning-tree guard loop interface configuration command.
Examples
This example shows how to enable root guard on all the VLANs associated with the specified port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# spanning-tree guard root
This example shows how to enable loop guard on all the VLANs associated with the specified port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# spanning-tree guard loop
You can verify your settings by entering the show running-config privileged EXEC command.
Related Commands
|
|
---|---|
show running-config |
Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference, Release 12.2 > File Management Commands > Configuration File Management Commands. |
Sets the path cost for spanning-tree calculations. |
|
Prevents alternate or root ports from becoming designated ports because of a failure that leads to a unidirectional link. |
|
Configures the path cost for MST calculations. |
|
Configures an interface priority. |
|
Configures the MST root switch priority and timers based on the network diameter. |
|
Configures an interface priority. |
|
spanning-tree vlan priority |
Sets the switch priority for the specified spanning-tree instance. |
spanning-tree link-type
Use the spanning-tree link-type interface configuration command to override the default link-type setting, which is determined by the duplex mode of the interface, and to enable rapid spanning-tree transitions to the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree link-type {point-to-point | shared}
no spanning-tree link-type
Syntax Description
point-to-point |
Specify that the link type of an interface is point-to-point. |
shared |
Specify that the link type of an interface is shared. |
Defaults
The switch derives the link type of an interface from the duplex mode. A full-duplex interface is considered a point-to-point link, and a half-duplex interface is considered a shared link.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can override the default setting of the link type by using the spanning-tree link-type command. For example, a half-duplex link can be physically connected point-to-point to a single interface on a remote switch running the Multiple Spanning Tree Protocol (MSTP) or the rapid per-VLAN spanning-tree plus (rapid-PVST+) protocol and be enabled for rapid transitions.
Examples
This example shows how to specify the link type as shared (regardless of the duplex setting) and to prevent rapid transitions to the forwarding state:
Switch(config-if)# spanning-tree link-type shared
You can verify your setting by entering the show spanning-tree mst interface interface-id or the show spanning-tree interface interface-id privileged EXEC command.
Related Commands
|
|
---|---|
Restarts the protocol migration process (force the renegotiation with neighboring switches) on all interfaces or on the specified interface. |
|
show spanning-tree interface interface-id |
Displays spanning-tree state information for the specified interface. |
show spanning-tree mst interface interface-id |
Displays MST information for the specified interface. |
spanning-tree loopguard default
Use the spanning-tree loopguard default global configuration command to prevent alternate or root ports from becoming designated ports because of a failure that leads to a unidirectional link. Use the no form of this command to return to the default setting.
spanning-tree loopguard default
no spanning-tree loopguard default
Syntax Description
This command has no arguments or keywords.
Defaults
Loop guard is disabled.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can enable the loop guard feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
Loop guard is most effective when it is configured on the entire switched network. When the switch is operating in PVST+ or rapid-PVST+ mode, loop guard prevents alternate and root ports from becoming designated ports, and spanning tree does not send bridge protocol data units (BPDUs) on root or alternate ports. When the switch is operating in MST mode, BPDUs are not sent on nonboundary interfaces if the interface is blocked by loop guard in all MST instances. On a boundary interface, loop guard blocks the interface in all MST instances.
Loop guard operates only on interfaces that the spanning tree identifies as point-to-point.
You can override the setting of the spanning-tree loopguard default global configuration command by using the spanning-tree guard loop interface configuration command.
Examples
This example shows how to globally enable loop guard:
Switch(config)# spanning-tree loopguard default
You can verify your settings by entering the show running-config privileged EXEC command.
Related Commands
|
|
---|---|
show running-config |
Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference, Release 12.2 > File Management Commands > Configuration File Management Commands. |
spanning-tree guard loop |
Enables the loop guard feature on all the VLANs associated with the specified interface. |
spanning-tree mode
Use the spanning-tree mode global configuration command to enable per-VLAN spanning-tree plus (PVST+), rapid PVST+, or multiple spanning tree (MST) on your switch. Use the no form of this command to return to the default setting.
spanning-tree mode {mst | pvst | rapid-pvst}
no spanning-tree mode
Syntax Description
mst |
Enable MST and Rapid Spanning Tree Protocol (RSTP) (based on IEEE 802.1s and IEEE 802.1w). |
pvst |
Enable PVST+ (based on IEEE 802.1D). |
rapid-pvst |
Enable rapid PVST+ (based on IEEE 802.1w). |
Defaults
The default mode is PVST+.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The switch supports PVST+, rapid PVST+, and MSTP, but only one version can be active at any time: All VLANs run PVST+, all VLANs run rapid PVST+, or all VLANs run MSTP.
When you enable the MST mode, RSTP is automatically enabled.
Examples
This example shows to enable MST and RSTP on the switch:
Switch(config)# spanning-tree mode mst
This example shows to enable rapid PVST+ on the switch:
Switch(config)# spanning-tree mode rapid-pvst
You can verify your setting by entering the show running-config privileged EXEC command.
Related Commands
spanning-tree mst configuration
Use the spanning-tree mst configuration global configuration command to enter multiple spanning-tree (MST) configuration mode through which you configure the MST region. Use the no form of this command to return to the default settings.
spanning-tree mst configuration
no spanning-tree mst configuration
Syntax Description
This command has no arguments or keywords.
Defaults
The default mapping is that all VLANs are mapped to the common and internal spanning-tree (CIST) instance (instance 0).
The default name is an empty string.
The revision number is 0.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The spanning-tree mst configuration command enables the MST configuration mode. These configuration commands are available:
•abort: exits the MST region configuration mode without applying configuration changes.
•exit: exits the MST region configuration mode and applies all configuration changes.
•instance instance-id vlan vlan-range: maps VLANs to an MST instance. The range for the instance-id is 1 to 4094. The range for vlan-range is 1 to 4094. You can specify a single VLAN identified by VLAN ID number, a range of VLANs separated by a hyphen, or a series of VLANs separated by a comma.
•name name: sets the configuration name. The name string has a maximum length of 32 characters and is case sensitive.
•no: negates the instance, name, and revision commands or sets them to their defaults.
•private-vlan: Though visible in the command-line help strings, this command is not supported.
•revision version: sets the configuration revision number. The range is 0 to 65535.
•show [current | pending]: displays the current or pending MST region configuration.
In MST mode, the switch supports up to 65 MST instances. The number of VLANs that can be mapped to a particular MST instance is unlimited.
When you map VLANs to an MST instance, the mapping is incremental, and VLANs specified in the command are added to or removed from the VLANs that were previously mapped. To specify a range, use a hyphen; for example, instance 1 vlan 1-63 maps VLANs 1 to 63 to MST instance 1. To specify a series, use a comma; for example, instance 1 vlan 10, 20, 30 maps VLANs 10, 20, and 30 to MST instance 1.
All VLANs that are not explicitly mapped to an MST instance are mapped to the common and internal spanning tree (CIST) instance (instance 0) and cannot be unmapped from the CIST by using the no form of the command.
For two or more switches to be in the same MST region, they must have the same VLAN mapping, the same configuration revision number, and the same name.
Examples
This example shows how to enter MST configuration mode, map VLANs 10 to 20 to MST instance 1, name the region region1, set the configuration revision to 1, display the pending configuration, apply the changes, and return to global configuration mode:
Switch# spanning-tree mst configuration
Switch(config-mst)# instance 1 vlan 10-20
Switch(config-mst)# name region1
Switch(config-mst)# revision 1
Switch(config-mst)# show pending
Pending MST configuration
Name [region1]
Revision 1
Instance Vlans Mapped
-------- ---------------------
0 1-9,21-4094
1 10-20
-------------------------------
Switch(config-mst)# exit
Switch(config)#
This example shows how to add VLANs 1 to 100 to the ones already mapped (if any) to instance 2, to move VLANs 40 to 60 that were previously mapped to instance 2 to the CIST instance, to add VLAN 10 to instance 10, and to remove all the VLANs mapped to instance 2 and map them to the CIST instance:
Switch(config-mst)# instance 2 vlan 1-100
Switch(config-mst)# no instance 2 vlan 40-60
Switch(config-mst)# instance 10 vlan 10
Switch(config-mst)# no instance 2
You can verify your settings by entering the show pending MST configuration command.
Related Commands
|
|
---|---|
show spanning-tree mst configuration |
Displays the MST region configuration. |
spanning-tree mst cost
Use the spanning-tree mst cost interface configuration command to set the path cost for multiple spanning-tree (MST) calculations. If a loop occurs, spanning tree considers the path cost when selecting an interface to put in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree mst instance-id cost cost
no spanning-tree mst instance-id cost
Syntax Description
Defaults
The default path cost is computed from the interface bandwidth setting. These are the IEEE default path cost values:
•1000 Mb/s—20000
•100 Mb/s—200000
•10 Mb/s—2000000
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
When you configure the cost, higher values represent higher costs.
Examples
This example shows how to set a path cost of 250 on a port associated with instances 2 and 4:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# spanning-tree mst 2,4 cost 250
You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree mst interface interface-id |
Displays MST information for the specified interface. |
Configures an interface priority. |
|
Configures the switch priority for the specified spanning-tree instance. |
spanning-tree mst forward-time
Use the spanning-tree mst forward-time global configuration command to set the forward-delay time for all multiple spanning-tree (MST) instances. The forwarding time specifies how long each of the listening and learning states last before the interface begins forwarding. Use the no form of this command to return to the default setting.
spanning-tree mst forward-time seconds
no spanning-tree mst forward-time
Syntax Description
seconds |
Length of the listening and learning states. The range is 4 to 30 seconds. |
Defaults
The default is 15 seconds.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Changing the spanning-tree mst forward-time command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree forwarding time to 18 seconds for all MST instances:
Switch(config)# spanning-tree mst forward-time 18
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
Related Commands
spanning-tree mst hello-time
Use the spanning-tree mst hello-time global configuration command to set the interval between hello bridge protocol data units (BPDUs) sent by root switch configuration messages. Use the no form of this command to return to the default setting.
spanning-tree mst hello-time seconds
no spanning-tree mst hello-time
Syntax Description
seconds |
Interval between hello BPDUs sent by root switch configuration messages. The range is 1 to 10 seconds. |
Defaults
The default is 2 seconds.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
After you set the spanning-tree mst max-age seconds global configuration command, if a switch does not receive BPDUs from the root switch within the specified interval, the switch recomputes the spanning-tree topology. The max-age setting must be greater than the hello-time setting.
Changing the spanning-tree mst hello-time command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree hello time to 3 seconds for all multiple spanning-tree (MST) instances:
Switch(config)# spanning-tree mst hello-time 3
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
Related Commands
spanning-tree mst max-age
Use the spanning-tree mst max-age global configuration command to set the interval between messages that the spanning tree receives from the root switch. If a switch does not receive a bridge protocol data unit (BPDU) message from the root switch within this interval, it recomputes the spanning-tree topology. Use the no form of this command to return to the default setting.
spanning-tree mst max-age seconds
no spanning-tree mst max-age
Syntax Description
seconds |
Interval between messages the spanning tree receives from the root switch. The range is 6 to 40 seconds. |
Defaults
The default is 20 seconds.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
After you set the spanning-tree mst max-age seconds global configuration command, if a switch does not receive BPDUs from the root switch within the specified interval, the switch recomputes the spanning-tree topology. The max-age setting must be greater than the hello-time setting.
Changing the spanning-tree mst max-age command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree max-age to 30 seconds for all multiple spanning-tree (MST) instances:
Switch(config)# spanning-tree mst max-age 30
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
Related Commands
spanning-tree mst max-hops
Use the spanning-tree mst max-hops global configuration command to set the number of hops in a region before the bridge protocol data unit (BPDU) is discarded and the information held for an interface is aged. Use the no form of this command to return to the default setting.
spanning-tree mst max-hops hop-count
no spanning-tree mst max-hops
Syntax Description
hop-count |
Number of hops in a region before the BPDU is discarded. The range is 1 to 255 hops. |
Defaults
The default is 20 hops.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The root switch of the instance always sends a BPDU (or M-record) with a cost of 0 and the hop count set to the maximum value. When a switch receives this BPDU, it decrements the received remaining hop count by one and propagates the decremented count as the remaining hop count in the generated M-records. A switch discards the BPDU and ages the information held for the interface when the count reaches 0.
Changing the spanning-tree mst max-hops command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree max-hops to 10 for all multiple spanning-tree (MST) instances:
Switch(config)# spanning-tree mst max-hops 10
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
Related Commands
spanning-tree mst port-priority
Use the spanning-tree mst port-priority interface configuration command to configure an interface priority. If a loop occurs, the Multiple Spanning Tree Protocol (MSTP) can find the interface to put in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree mst instance-id port-priority priority
no spanning-tree mst instance-id port-priority
Syntax Description
Defaults
The default is 128.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can assign higher priority values (lower numerical values) to interfaces that you want selected first and lower priority values (higher numerical values) that you want selected last. If all interfaces have the same priority value, the multiple spanning tree (MST) puts the interface with the lowest interface number in the forwarding state and blocks other interfaces.
Examples
This example shows how to increase the likelihood that the interface associated with spanning-tree instances 20 and 22 is placed into the forwarding state if a loop occurs:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# spanning-tree mst 20,22 port-priority 0
You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree mst interface interface-id |
Displays MST information for the specified interface. |
Sets the path cost for MST calculations. |
|
Sets the switch priority for the specified spanning-tree instance. |
spanning-tree mst pre-standard
Use the spanning-tree mst pre-standard interface configuration command to configure a port to send only prestandard bridge protocol data units (BPDUs).
spanning-tree mst pre-standard
no spanning-tree mst pre-standard
Syntax Description
This command has no arguments or keywords.
Command Default
The default state is automatic detection of prestandard neighbors.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The port can accept both prestandard and standard BPDUs. If the neighbor types are mismatched, only the common and internal spanning tree (CIST) runs on this interface.
Note If a switch port is connected to a switch running prestandard Cisco IOS software, you must use the spanning-tree mst pre-standard interface configuration command on the port. If you do not configure the port to send only prestandard BPDUs, the Multiple STP (MSTP) performance might diminish.
When the port is configured to automatically detect prestandard neighbors, the prestandard flag always appears in the show spanning-tree mst commands.
Examples
This example shows how to configure a port to send only prestandard BPDUs:
Switch(config-if)# spanning-tree mst pre-standard
You can verify your settings by entering the show spanning-tree mst privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree mst instance-id |
Displays multiple spanning-tree (MST) information, including the prestandard flag, for the specified interface. |
spanning-tree mst priority
Use the spanning-tree mst priority global configuration command to set the switch priority for the specified spanning-tree instance. Use the no form of this command to return to the default setting.
spanning-tree mst instance-id priority priority
no spanning-tree mst instance-id priority
Syntax Description
Defaults
The default is 32768.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Examples
This example shows how to set the spanning-tree priority to 8192 for multiple spanning-tree instances (MST) 20 to 21:
Switch(config)# spanning-tree mst 20-21 priority 8192
You can verify your settings by entering the show spanning-tree mst instance-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree mst instance-id |
Displays MST information for the specified interface. |
Sets the path cost for MST calculations. |
|
Configures an interface priority. |
spanning-tree mst root
Use the spanning-tree mst root global configuration command to configure the multiple spanning-tree (MST) root switch priority and timers based on the network diameter. Use the no form of this command to return to the default settings.
spanning-tree mst instance-id root {primary | secondary} [diameter net-diameter
[hello-time seconds]]
no spanning-tree mst instance-id root
Syntax Description
Defaults
The primary root switch priority is 24576.
The secondary root switch priority is 28672.
The hello time is 2 seconds.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Use the spanning-tree mst instance-id root command only on backbone switches.
When you enter the spanning-tree mst instance-id root command, the software tries to set a high enough priority to make this switch the root of the spanning-tree instance. Because of the extended system ID support, the switch sets the switch priority for the instance to 24576 if this value will cause this switch to become the root for the specified instance. If any root switch for the specified instance has a switch priority lower than 24576, the switch sets its own priority to 4096 less than the lowest switch priority. (4096 is the value of the least-significant bit of a 4-bit switch priority value.)
When you enter the spanning-tree mst instance-id root secondary command, because of support for the extended system ID, the software changes the switch priority from the default value (32768) to 28672. If the root switch fails, this switch becomes the next root switch (if the other switches in the network use the default switch priority of 32768 and are therefore unlikely to become the root switch).
Examples
This example shows how to configure the switch as the root switch for instance 10 with a network diameter of 4:
Switch(config)# spanning-tree mst 10 root primary diameter 4
This example shows how to configure the switch as the secondary root switch for instance 10 with a network diameter of 4:
S
witch(config)# spanning-tree mst 10 root secondary diameter 4
You can verify your settings by entering the show spanning-tree mst instance-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree mst instance-id |
Displays MST information for the specified instance. |
Sets the forward-delay time for all MST instances. |
|
Sets the interval between hello BPDUs sent by root switch configuration messages. |
|
Sets the interval between messages that the spanning tree receives from the root switch. |
|
Sets the number of hops in a region before the BPDU is discarded. |
spanning-tree port-priority
Use the spanning-tree port-priority interface configuration command to configure an interface priority. If a loop occurs, spanning tree can find the interface to put in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree [vlan vlan-id] port-priority priority
no spanning-tree [vlan vlan-id] port-priority
Syntax Description
Defaults
The default is 128.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
If the variable vlan-id is omitted, the command applies to the spanning-tree instance associated with VLAN 1.
You can set the priority on a VLAN that has no interfaces assigned to it. The setting takes effect when you assign the interface to the VLAN.
If you configure an interface with both the spanning-tree vlan vlan-id port-priority priority command and the spanning-tree port-priority priority command, the spanning-tree vlan vlan-id port-priority priority command takes effect.
Examples
This example shows how to increase the likelihood that a port will be put in the forwarding state if a loop occurs:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# spanning-tree vlan 20 port-priority 0
This example shows how to set the port-priority value on VLANs 20 to 25:
Switch(config-if)# spanning-tree vlan 20-25 port-priority 0
You can verify your settings by entering the show spanning-tree interface interface-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree interface interface-id |
Displays spanning-tree information for the specified interface. |
Sets the path cost for spanning-tree calculations. |
|
spanning-tree vlan priority |
Sets the switch priority for the specified spanning-tree instance. |
spanning-tree portfast (global configuration)
Use the spanning-tree portfast global configuration command to globally enable bridge protocol data unit (BPDU) filtering on Port Fast-enabled interfaces, the BPDU guard feature on Port Fast-enabled interfaces, or the Port Fast feature on all nontrunking interfaces. The BPDU filtering feature prevents the switch interface from sending or receiving BPDUs. The BPDU guard feature puts Port Fast-enabled interfaces that receive BPDUs in an error-disabled state. Use the no form of this command to return to the default settings.
spanning-tree portfast {bpdufilter default | bpduguard default | default}
no spanning-tree portfast {bpdufilter default | bpduguard default | default}
Syntax Description
Defaults
The BPDU filtering, the BPDU guard, and the Port Fast features are disabled on all interfaces unless they are individually configured.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can enable these features when the switch is operating in the per-VLAN spanning-tree plus (PVST+) rapid-PVST+, or the multiple spanning-tree (MST) mode.
Use the spanning-tree portfast bpdufilter default global configuration command to globally enable BPDU filtering on interfaces that are Port Fast-enabled (the interfaces are in a Port Fast-operational state). The interfaces still send a few BPDUs at link-up before the switch begins to filter outbound BPDUs. You should globally enable BPDU filtering on a switch so that hosts connected to switch interfaces do not receive BPDUs. If a BPDU is received on a Port Fast-enabled interface, the interface loses its Port Fast-operational status and BPDU filtering is disabled.
You can override the spanning-tree portfast bpdufilter default global configuration command by using the spanning-tree bdpufilter interface configuration command.
Use the spanning-tree portfast bpduguard default global configuration command to globally enable BPDU guard on interfaces that are in a Port Fast-operational state. In a valid configuration, Port Fast-enabled interfaces do not receive BPDUs. Receiving a BPDU on a Port Fast-enabled interface signals an invalid configuration, such as the connection of an unauthorized device, and the BPDU guard feature puts the interface in the error-disabled state. The BPDU guard feature provides a secure response to invalid configurations because you must manually put the interface back in service. Use the BPDU guard feature in a service-provider network to prevent an access port from participating in the spanning tree.
You can override the spanning-tree portfast bpduguard default global configuration command by using the spanning-tree bdpuguard interface configuration command.
Use the spanning-tree portfast default global configuration command to globally enable the Port Fast feature on all nontrunking interfaces. Configure Port Fast only on interfaces that connect to end stations; otherwise, an accidental topology loop could cause a data packet loop and disrupt switch and network operation. A Port Fast-enabled interface moves directly to the spanning-tree forwarding state when linkup occurs without waiting for the standard forward-delay time.
You can override the spanning-tree portfast default global configuration command by using the spanning-tree portfast interface configuration command. You can use the no spanning-tree portfast default global configuration command to disable Port Fast on all interfaces unless they are individually configured with the spanning-tree portfast interface configuration command.
Examples
This example shows how to globally enable the BPDU filtering feature:
Switch(config)#
spanning-tree portfast bpdufilter default
This example shows how to globally enable the BPDU guard feature:
Switch(config)#
spanning-tree portfast bpduguard default
This example shows how to globally enable the Port Fast feature on all nontrunking interfaces:
Switch(config)#
spanning-tree portfast default
You can verify your settings by entering the show running-config privileged EXEC command.
Related Commands
spanning-tree portfast (interface configuration)
Use the spanning-tree portfast interface configuration command to enable the Port Fast feature on an interface in all its associated VLANs. When the Port Fast feature is enabled, the interface changes directly from a blocking state to a forwarding state without making the intermediate spanning-tree state changes. Use the no form of this command to return to the default setting.
spanning-tree portfast [disable | trunk]
no spanning-tree portfast
Syntax Description
disable |
(Optional) Disable the Port Fast feature on the specified interface. |
trunk |
(Optional) Enable the Port Fast feature on a trunking interface. |
Defaults
The Port Fast feature is disabled on all interfaces; however, it is automatically enabled on dynamic-access ports.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Use this feature only on interfaces that connect to end stations; otherwise, an accidental topology loop could cause a data packet loop and disrupt switch and network operation.
To enable Port Fast on trunk ports, you must use the spanning-tree portfast trunk interface configuration command. The spanning-tree portfast command is not supported on trunk ports.
You can enable this feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
This feature affects all VLANs on the interface.
An interface with the Port Fast feature enabled is moved directly to the spanning-tree forwarding state without the standard forward-time delay.
You can use the spanning-tree portfast default global configuration command to globally enable the Port Fast feature on all nontrunking interfaces. However, the spanning-tree portfast interface configuration command can override the global setting.
If you configure the spanning-tree portfast default global configuration command, you can disable Port Fast on an interface that is not a trunk interface by using the spanning-tree portfast disable interface configuration command.
Examples
This example shows how to enable the Port Fast feature on a port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# spanning-tree portfast
You can verify your settings by entering the show running-config privileged EXEC command.
Related Commands
spanning-tree transmit hold-count
Use the spanning-tree transmit hold-count global configuration command to configure the number of bridge protocol data units (BPDUs) sent every second. Use the no form of this command to return to the default setting.
spanning-tree transmit hold-count [value]
no spanning-tree transmit hold-count [value]
Syntax Description
value |
(Optional) Number of BPDUs sent every second. The range is 1 to 20. |
Defaults
The default is 6.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Increasing the transmit hold-count value can have a significant impact on CPU utilization when the switch is in rapid-per-VLAN spanning-tree plus (rapid-PVST+) mode. Decreasing this value might slow down convergence. We recommend using the default setting.
Examples
This example shows how to set the transmit hold count to 8:
Switch(config)# spanning-tree transmit hold-count 8
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
Related Commands
|
|
---|---|
Displays the multiple spanning-tree (MST) region configuration and status, including the transmit hold count. |
spanning-tree uplinkfast
Use the spanning-tree uplinkfast global configuration command to accelerate the choice of a new root port when a link or switch fails or when the spanning tree reconfigures itself. Use the no form of this command to return to the default setting.
spanning-tree uplinkfast [max-update-rate pkts-per-second]
no spanning-tree uplinkfast [max-update-rate]
Syntax Description
max-update-rate pkts-per-second |
(Optional) The number of packets per second at which update packets are sent. The range is 0 to 32000. |
Defaults
UplinkFast is disabled.
The update rate is 150 packets per second.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Use this command only on access switches.
You can configure the UplinkFast feature for rapid PVST+ or for multiple spanning-tree (MST) mode, but the feature remains disabled (inactive) until you change the spanning-tree mode to PVST+.
When you enable UplinkFast, it is enabled for the entire switch and cannot be enabled for individual VLANs.
When UplinkFast is enabled, the switch priority of all VLANs is set to 49152. If you change the path cost to a value less than 3000 and you enable UplinkFast or UplinkFast is already enabled, the path cost of all interfaces and VLAN trunks is increased by 3000 (if you change the path cost to 3000 or above, the path cost is not altered). The changes to the switch priority and the path cost reduces the chance that a switch will become the root switch.
When UplinkFast is disabled, the switch priorities of all VLANs and path costs of all interfaces are set to default values if you did not modify them from their defaults.
When spanning tree detects that the root port has failed, UplinkFast immediately changes to an alternate root port, changing the new root port directly to forwarding state. During this time, a topology change notification is sent.
Do not enable the root guard on interfaces that will be used by the UplinkFast feature. With UplinkFast, the backup interfaces (in the blocked state) replace the root port in the case of a failure. However, if root guard is also enabled, all the backup interfaces used by the UplinkFast feature are placed in the root-inconsistent state (blocked) and prevented from reaching the forwarding state.
If you set the max-update-rate to 0, station-learning frames are not generated, so the spanning-tree topology converges more slowly after a loss of connectivity.
Examples
This example shows how to enable UplinkFast:
Switch(config)# spanning-tree uplinkfast
You can verify your setting by entering the show spanning-tree summary privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree summary |
Displays a summary of the spanning-tree interface states. |
spanning-tree vlan root primary |
Forces this switch to be the root switch. |
spanning-tree vlan
Use the spanning-tree vlan global configuration command to configure spanning tree on a per-VLAN basis. Use the no form of this command to return to the default setting.
spanning-tree vlan vlan-id [forward-time seconds | hello-time seconds | max-age seconds |
priority priority | root {primary | secondary} [diameter net-diameter
[hello-time seconds]]]
no spanning-tree vlan vlan-id [forward-time | hello-time | max-age | priority | root]
Syntax Description
Defaults
Spanning tree is enabled on all VLANs.
The forward-delay time is 15 seconds.
The hello time is 2 seconds.
The max-age is 20 seconds.
The primary root switch priority is 24576.
The secondary root switch priority is 28672.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Disabling the STP causes the VLAN to stop participating in the spanning-tree topology. Interfaces that are administratively down remain down. Received BPDUs are forwarded like other multicast frames. The VLAN does not detect and prevent loops when STP is disabled.
You can disable the STP on a VLAN that is not currently active and verify the change by using the show running-config or the show spanning-tree vlan vlan-id privileged EXEC command. The setting takes effect when the VLAN is activated.
When disabling or re-enabling the STP, you can specify a range of VLANs that you want to disable or enable.
When a VLAN is disabled and then enabled, all assigned VLANs continue to be its members. However, all spanning-tree bridge parameters are returned to their previous settings (the last setting before the VLAN was disabled).
You can enable spanning-tree options on a VLAN that has no interfaces assigned to it. The setting takes effect when you assign interfaces to it.
When setting the max-age seconds, if a switch does not receive BPDUs from the root switch within the specified interval, it recomputes the spanning-tree topology. The max-age setting must be greater than the hello-time setting.
The spanning-tree vlan vlan-id root command should be used only on backbone switches.
When you enter the spanning-tree vlan vlan-id root command, the software checks the switch priority of the current root switch for each VLAN. Because of the extended system ID support, the switch sets the switch priority for the specified VLAN to 24576 if this value will cause this switch to become the root for the specified VLAN. If any root switch for the specified VLAN has a switch priority lower than 24576, the switch sets its own priority for the specified VLAN to 4096 less than the lowest switch priority. (4096 is the value of the least-significant bit of a 4-bit switch priority value.)
When you enter the spanning-tree vlan vlan-id root secondary command, because of support for the extended system ID, the software changes the switch priority from the default value (32768) to 28672. If the root switch should fail, this switch becomes the next root switch (if the other switches in the network use the default switch priority of 32768, and therefore, are unlikely to become the root switch).
Examples
This example shows how to disable the STP on VLAN 5:
Switch(config)# no spanning-tree vlan 5
You can verify your setting by entering the show spanning-tree privileged EXEC command. In this instance, VLAN 5 does not appear in the list.
This example shows how to set the spanning-tree forwarding time to 18 seconds for VLANs 20 and 25:
Switch(config)# spanning-tree vlan 20,25 forward-time 18
This example shows how to set the spanning-tree hello-delay time to 3 seconds for VLANs 20 to 24:
Switch(config)# spanning-tree vlan 20-24 hello-time 3
This example shows how to set spanning-tree max-age to 30 seconds for VLAN 20:
Switch(config)# spanning-tree vlan 20 max-age 30
This example shows how to reset the max-age parameter to the default value for spanning-tree instance 100 and 105 to 108:
Switch(config)# no spanning-tree vlan 100, 105-108 max-age
This example shows how to set the spanning-tree priority to 8192 for VLAN 20:
Switch(config)# spanning-tree vlan 20 priority 8192
This example shows how to configure the switch as the root switch for VLAN 10 with a network diameter of 4:
Switch(config)# spanning-tree vlan 10 root primary diameter 4
This example shows how to configure the switch as the secondary root switch for VLAN 10 with a network diameter of 4:
Switch(config)#
spanning-tree vlan 10 root secondary diameter 4
You can verify your settings by entering the show spanning-tree vlan vlan-id privileged EXEC command.
Related Commands
|
|
---|---|
show spanning-tree vlan |
Displays spanning-tree information. |
Sets the path cost for spanning-tree calculations. |
|
Enables the root guard or the loop guard feature for all the VLANs associated with the selected interface. |
|
Sets an interface priority. |
|
Globally enables the BPDU filtering or the BPDU guard feature on Port Fast-enabled interfaces or enables the Port Fast feature on all nontrunking interfaces. |
|
Enables the Port Fast feature on an interface in all its associated VLANs. |
|
Enables the UplinkFast feature, which accelerates the choice of a new root port. |
speed
Use the speed interface configuration command to specify the speed of a 10/100 Mb/s or 10/100/1000 Mb/s port. Use the no or default form of this command to return the port to its default value.
speed {10 | 100 | 1000 | auto [10 | 100 | 1000] | nonegotiate}
no speed
Syntax Description
Defaults
The default is auto.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
If an SFP module port is connected to a device that does not support autonegotiation, you can configure the speed to not negotiate (nonegotiate).
If the speed is set to auto, the switch negotiates with the device at the other end of the link for the speed setting and then forces the speed setting to the negotiated value. The duplex setting remains as configured on each end of the link, which could result in a duplex setting mismatch.
If both ends of the line support autonegotiation, we highly recommend the default autonegotiation settings. If one interface supports autonegotiation and the other end does not, do use the auto setting on the supported side, but set the duplex and speed on the other side.
For guidelines on setting the switch speed and duplex parameters, see the "Configuring Interface Characteristics" chapter in the software configuration guide for this release.
Examples
This example shows how to set the speed on a port to 100 Mb/s:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# speed 100
This example shows how to set a port to autonegotiate at only 10 Mb/s:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# speed auto 10
This example shows how to set a port to autonegotiate at only 10 or 100 Mb/s:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# speed auto 10 100
You can verify your settings by entering the show interfaces privileged EXEC command.
Related Commands
|
|
---|---|
Specifies the duplex mode of operation. |
|
Displays the statistical information specific to all interfaces or to a specific interface. |
storm-control
Use the storm-control interface configuration command to enable broadcast, multicast, or unicast storm control and to set threshold levels on an interface. Use the no form of this command to return to the default setting.
storm-control {{broadcast | multicast | unicast} level {level [level-low] | bps bps [bps-low] | pps pps [pps-low]}} | {action {shutdown | trap}}
no storm-control {{broadcast | multicast | unicast} level} | {action {shutdown | trap}}
Syntax Description
Defaults
Broadcast, multicast, and unicast storm control are disabled.
The default action is to filter traffic and to not send an SNMP trap.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Storm control is supported only on physical interfaces. It is not supported on EtherChannel port channels, even though it is available in the command-line interface (CLI).
The storm-control suppression level can be entered as a percentage of total bandwidth of the port, as a rate in packets per second at which traffic is received, or as a rate in bits per second at which traffic is received.
When specified as a percentage of total bandwidth, a suppression value of 100 percent means that no limit is placed on the specified traffic type. A value of level 0 0 means that all broadcast, multicast, or unicast traffic on that port is blocked. Storm control is enabled only when the rising suppression level is less than 100 percent. If no other storm-control configuration is specified, the default action is to filter the traffic causing the storm and to send no SNMP traps.
Note When the storm control threshold for multicast traffic is reached, all multicast traffic except control traffic, such as bridge protocol data unit (BDPU) and Cisco Discovery Protocol (CDP) frames, are blocked.
The trap and shutdown options are independent of each other.
If you configure the action to be taken as shutdown (the port is error-disabled during a storm) when a packet storm is detected, you must use the no shutdown interface configuration command to bring the interface out of this state. If you do not specify the shutdown action, specify the action as trap (the switch generates a trap when a storm is detected).
When a storm occurs and the action is to filter traffic, if the falling suppression level is not specified, the switch blocks all traffic until the traffic rate drops below the rising suppression level. If the falling suppression level is specified, the switch blocks traffic until the traffic rate drops below this level.
Note Storm control is supported on physical interfaces. You can also configure storm control on an EtherChannel. When storm control is configured on an EtherChannel, the storm control settings propagate to the EtherChannel physical interfaces.
When a broadcast storm occurs and the action is to filter traffic, the switch blocks only broadcast traffic.
For more information, see the software configuration guide for this release.
Examples
This example shows how to enable broadcast storm control with a 75.5-percent rising suppression level:
Switch(config-if)# storm-control broadcast level 75.5
This example shows how to enable unicast storm control on a port with a 87-percent rising suppression level and a 65-percent falling suppression level:
Switch(config-if)# storm-control unicast level 87 65
This example shows how to enable multicast storm control on a port with a 2000-packets-per-second rising suppression level and a 1000-packets-per-second falling suppression level:
Switch(config-if)# storm-control multicast level pps 2k 1k
This example shows how to enable the shutdown action on a port:
Switch(config-if)# storm-control action shutdown
You can verify your settings by entering the show storm-control privileged EXEC command.
Related Commands
|
|
---|---|
Displays broadcast, multicast, or unicast storm control settings on all interfaces or on a specified interface. |
switchport access
Use the switchport access interface configuration command to configure a port as a static-access or dynamic-access port. If the switchport mode is set to access, the port operates as a member of the specified VLAN. If set to dynamic, the port starts discovery of VLAN assignment based on the incoming packets it receives. Use the no form of this command to reset the access mode to the default VLAN for the switch.
switchport access vlan {vlan-id | dynamic}
no switchport access vlan
Syntax Description
Defaults
The default access VLAN and trunk interface native VLAN is a default VLAN corresponding to the platform or interface hardware.
A dynamic-access port is initially a member of no VLAN and receives its assignment based on the packet it receives.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The no switchport access command resets the access mode VLAN to the appropriate default VLAN for the device.
The port must be in access mode before the switchport access vlan command can take effect.
An access port can be assigned to only one VLAN.
The VMPS server (such as a Catalyst 6000 series switch) must be configured before a port is configured as dynamic.
These restrictions apply to dynamic-access ports:
•The software implements the VLAN Query Protocol (VQP) client, which can query a VMPS such as a Catalyst 6000 series switch. The Catalyst 2960 switches are not VMPS servers. The VMPS server must be configured before a port is configured as dynamic.
•Use dynamic-access ports only to connect end stations. Connecting them to switches or routers (that use bridging protocols) can cause a loss of connectivity.
•Configure the network so that STP does not put the dynamic-access port into an STP blocking state. The Port Fast feature is automatically enabled on dynamic-access ports.
•Dynamic-access ports can only be in one VLAN and do not use VLAN tagging.
•Dynamic-access ports cannot be configured as
–Members of an EtherChannel port group (dynamic-access ports cannot be grouped with any other port, including other dynamic ports).
–Source or destination ports in a static address entry.
–Monitor ports.
Examples
This example shows how to change a switched port interface that is operating in access mode to operate in VLAN 2 instead of the default VLAN:
Switch(config-if)#
switchport access vlan 2
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command and examining information in the Administrative Mode and Operational Mode rows.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including port blocking and port protection settings. |
Configures the VLAN membership mode of a port. |
switchport block
Use the switchport block interface configuration command to prevent unknown multicast or unicast packets from being forwarded. Use the no form of this command to allow forwarding unknown multicast or unicast packets.
switchport block {multicast | unicast}
no switchport block {multicast | unicast}
Syntax Description
multicast |
Specify that unknown multicast traffic should be blocked. |
unicast |
Specify that unknown unicast traffic should be blocked. |
Defaults
Unknown multicast and unicast traffic is not blocked.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
By default, all traffic with unknown MAC addresses is sent to all ports. You can block unknown multicast or unicast traffic on protected or nonprotected ports. If unknown multicast or unicast traffic is not blocked on a protected port, there could be security issues.
Blocking unknown multicast or unicast traffic is not automatically enabled on protected ports; you must explicitly configure it.
For more information about blocking packets, see the software configuration guide for this release.
Examples
This example shows how to block unknown multicast traffic on an interface:
Switch(config-if)# switchport block multicast
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including port blocking and port protection settings. |
switchport host
Use the switchport host interface configuration command to optimize a port for a host connection. The no form of this command has no affect on the system.
switchport host
Syntax Description
This command has no arguments or keywords.
Defaults
The default is for the port to not be optimized for a host connection.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
To optimize the port for a host connection, the switchport host command sets switch port mode to access, enables spanning tree Port Fast, and disables channel grouping. Only an end station can accept this configuration.
Because spanning tree Port Fast is enabled, you should enter the switchport host command only on ports that are connected to a single host. Connecting other switches, hubs, concentrators, or bridges to a fast-start port can cause temporary spanning-tree loops.
Enable the switchport host command to decrease the time that it takes to start up packet forwarding.
Examples
This example shows how to optimize the port configuration for a host connection:
Switch(config-if)# switchport host
switchport mode will be set to access
spanning-tree portfast will be enabled
channel group will be disabled
Switch(config-if)#
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including switchport mode. |
switchport mode
Use the switchport mode interface configuration command to configure the VLAN membership mode of a port. Use the no form of this command to reset the mode to the appropriate default for the device.
switchport mode {access | dynamic {auto | desirable} | trunk}
no switchport mode {access | dynamic | trunk}
Syntax Description
Defaults
The default mode is dynamic auto.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
A configuration that uses the access or trunk keywords takes effect only when you configure the port in the appropriate mode by using the switchport mode command. The static-access and trunk configuration are saved, but only one configuration is active at a time.
When you enter access mode, the interface changes to permanent nontrunking mode and negotiates to convert the link into a nontrunk link even if the neighboring interface does not agree to the change.
When you enter trunk mode, the interface changes to permanent trunking mode and negotiates to convert the link into a trunk link even if the interface connecting to it does not agree to the change.
When you enter dynamic auto mode, the interface converts the link to a trunk link if the neighboring interface is set to trunk or desirable mode.
When you enter dynamic desirable mode, the interface becomes a trunk interface if the neighboring interface is set to trunk, desirable, or auto mode.
To autonegotiate trunking, the interfaces must be in the same VLAN Trunking Protocol (VTP) domain. Trunk negotiation is managed by the Dynamic Trunking Protocol (DTP), which is a point-to-point protocol. However, some internetworking devices might forward DTP frames improperly, which could cause misconfigurations. To avoid this, you should configure interfaces connected to devices that do not support DTP to not forward DTP frames, which turns off DTP.
•If you do not intend to trunk across those links, use the switchport mode access interface configuration command to disable trunking.
•To enable trunking to a device that does not support DTP, use the switchport mode trunk and switchport nonegotiate interface configuration commands to cause the interface to become a trunk but to not generate DTP frames.
Access ports and trunk ports are mutually exclusive.
The IEEE 802.1x feature interacts with switchport modes in these ways:
•If you try to enable IEEE 802.1x on a trunk port, an error message appears, and IEEE 802.1x is not enabled. If you try to change the mode of an IEEE 802.1x-enabled port to trunk, the port mode is not changed.
•If you try to enable IEEE 802.1x on a port set to dynamic auto or dynamic desirable, an error message appears, and IEEE 802.1x is not enabled. If you try to change the mode of an IEEE 802.1x-enabled port to dynamic auto or dynamic desirable, the port mode is not changed.
•If you try to enable IEEE 802.1x on a dynamic-access (VLAN Query Protocol [VQP]) port, an error message appears, and IEEE 802.1x is not enabled. If you try to change an IEEE 802.1x-enabled port to dynamic VLAN assignment, an error message appears, and the VLAN configuration is not changed.
Examples
This example shows how to configure a port for access mode:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# switchport mode access
This example shows how set the port to dynamic desirable mode:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# switchport mode dynamic desirable
This example shows how to configure a port for trunk mode:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# switchport mode trunk
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command and examining information in the Administrative Mode and Operational Mode rows.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including port blocking and port protection settings. |
Configures a port as a static-access or dynamic-access port. |
|
Configures the trunk characteristics when an interface is in trunking mode. |
switchport nonegotiate
Use the switchport nonegotiate interface configuration command to specify that Dynamic Trunking Protocol (DTP) negotiation packets are not sent on the Layer 2 interface. The switch does not engage in DTP negotiation on this interface. Use the no form of this command to return to the default setting.
switchport nonegotiate
no switchport nonegotiate
Syntax Description
This command has no arguments or keywords.
Defaults
The default is to use DTP negotiation to learn the trunking status.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The no form of the switchport nonegotiate command removes nonegotiate status.
This command is valid only when the interface switchport mode is access or trunk (configured by using the switchport mode access or the switchport mode trunk interface configuration command). This command returns an error if you attempt to execute it in dynamic (auto or desirable) mode.
Internetworking devices that do not support DTP might forward DTP frames improperly and cause misconfigurations. To avoid this, you should turn off DTP by using the switchport no negotiate command to configure the interfaces connected to devices that do not support DTP to not forward DTP frames.
When you enter the switchport nonegotiate command, DTP negotiation packets are not sent on the interface. The device does or does not trunk according to the mode parameter: access or trunk.
•If you do not intend to trunk across those links, use the switchport mode access interface configuration command to disable trunking.
•To enable trunking on a device that does not support DTP, use the switchport mode trunk and switchport nonegotiate interface configuration commands to cause the interface to become a trunk but to not generate DTP frames.
Examples
This example shows how to cause a port to refrain from negotiating trunking mode and to act as a trunk or access port (depending on the mode set):
Switch(config)# interface gigabitethernet0/1
Switch(config-if)#
switchport nonegotiate
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including port blocking and port protection settings. |
Configures the VLAN membership mode of a port. |
switchport port-security
Use the switchport port-security interface configuration command without keywords to enable port security on the interface. Use the keywords to configure secure MAC addresses, sticky MAC address learning, a maximum number of secure MAC addresses, or the violation mode. Use the no form of this command to disable port security or to set the parameters to their default states.
switchport port-security [mac-address mac-address [vlan {vlan-id | {access | voice}}] | mac-address sticky [mac-address | vlan {vlan-id | {access | voice}}]] [maximum value [vlan {vlan-list | {access | voice}}]]
no switchport port-security [mac-address mac-address [vlan {vlan-id | {access | voice}}] | mac-address sticky [mac-address | vlan {vlan-id | {access | voice}}]] [maximum value [vlan {vlan-list | {access | voice}}]]
switchport port-security [aging] [violation {protect | restrict | shutdown | shutdown vlan}]
no switchport port-security [aging] [violation {protect | restrict | shutdown | shutdown vlan}]
Syntax Description
aging |
(Optional) See the switchport port-security aging command. |
mac-address mac-address |
(Optional) Specify a secure MAC address for the interface by entering a 48-bit MAC address. You can add additional secure MAC addresses up to the maximum value configured. |
vlan vlan-id |
(Optional) On a trunk port only, specify the VLAN ID and the MAC address. If no VLAN ID is specified, the native VLAN is used. |
vlan access |
(Optional) On an access port only, specify the VLAN as an access VLAN. |
vlan voice |
(Optional) On an access port only, specify the VLAN as a voice VLAN. Note The voice keyword is available only if voice VLAN is configured on a port and if that port is not the access VLAN. |
mac-address sticky [mac-address] |
(Optional) Enable the interface for sticky learning by entering only the mac-address sticky keywords. When sticky learning is enabled, the interface adds all secure MAC addresses that are dynamically learned to the running configuration and converts these addresses to sticky secure MAC addresses. (Optional) Enter a mac-address to specify a sticky secure MAC address. |
maximum value |
(Optional) Set the maximum number of secure MAC addresses for the interface.The maximum number of secure MAC addresses that you can configure on a switch is set by the maximum number of available MAC addresses allowed in the system. For more information, see the global configuration command. This number represents the total of available MAC addresses, including those used for other Layer 2 functions and any other secure MAC addresses configured on interfaces. The default setting is 1. |
vlan [vlan-list] |
(Optional) For trunk ports, you can set the maximum number of secure MAC addresses on a VLAN. If the vlan keyword is not entered, the default value is used. •vlan—set a per-VLAN maximum value. •vlan vlan-list—set a per-VLAN maximum value on a range of VLANs separated by a hyphen or a series of VLANs separated by commas. For nonspecified VLANs, the per-VLAN maximum value is used. |
violation |
(Optional) Set the security violation mode or the action to be taken if port security is violated. The default is shutdown. |
protect |
Set the security violation protect mode. In this mode, when the number of port secure MAC addresses reaches the maximum limit allowed on the port, packets with unknown source addresses are dropped until you remove a sufficient number of secure MAC addresses to drop below the maximum value or increase the number of maximum allowable addresses. You are not notified that a security violation has occurred. Note We do not recommend configuring the protect mode on a trunk port. The protect mode disables learning when any VLAN reaches its maximum limit, even if the port has not reached its maximum limit. |
restrict |
Set the security violation restrict mode. In this mode, when the number of secure MAC addresses reaches the limit allowed on the port, packets with unknown source addresses are dropped until you remove a sufficient number of secure MAC addresses or increase the number of maximum allowable addresses. An SNMP trap is sent, a syslog message is logged, and the violation counter increments. |
shutdown |
Set the security violation shutdown mode. In this mode, the interface is error-disabled when a violation occurs and the port LED turns off. An SNMP trap is sent, a syslog message is logged, and the violation counter increments. When a secure port is in the error-disabled state, you can bring it out of this state by entering the errdisable recovery cause psecure-violation global configuration command, or you can manually re-enable it by entering the shutdown and no shut down interface configuration commands. |
shutdown vlan |
Set the security violation mode to per-VLAN shutdown. In this mode, only the VLAN on which the violation occurred is error-disabled. |
Defaults
The default is to disable port security.
When port security is enabled and no keywords are entered, the default maximum number of secure MAC addresses is 1.
The default violation mode is shutdown.
Sticky learning is disabled.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
A secure port has the following limitations:
•A secure port can be an access port or a trunk port; it cannot be a dynamic access port.
•A secure port cannot be a protected port.
•A secure port cannot be a destination port for Switched Port Analyzer (SPAN).
•A secure port cannot be a private VLAN port.
•A secure port cannot belong to a Fast EtherChannel or Gigabit EtherChannel port group.
•You cannot configure static secure or sticky secure MAC addresses in the voice VLAN.
•When you enable port security on an interface that is also configured with a voice VLAN, set the maximum allowed secure addresses on the port to two. When the port is connected to a Cisco IP phone, the IP phone requires one MAC address. The Cisco IP phone address is learned on the voice VLAN, but is not learned on the access VLAN. If you connect a single PC to the Cisco IP phone, no additional MAC addresses are required. If you connect more than one PC to the Cisco IP phone, you must configure enough secure addresses to allow one for each PC and one for the Cisco IP phone.
•Voice VLAN is supported only on access ports and not on trunk ports.
•When you enter a maximum secure address value for an interface, if the new value is greater than the previous value, the new value overrides the previously configured value. If the new value is less than the previous value and the number of configured secure addresses on the interface exceeds the new value, the command is rejected.
•The switch does not support port security aging of sticky secure MAC addresses.
A security violation occurs when the maximum number of secure MAC addresses are in the address table and a station whose MAC address is not in the address table attempts to access the interface or when a station whose MAC address is configured as a secure MAC address on another secure port attempts to access the interface.
When a secure port is in the error-disabled state, you can bring it out of this state by entering the errdisable recovery cause psecure-violation global configuration command. You can manually re-enable the port by entering the shutdown and no shut down interface configuration commands or by using the clear errdisable interface privileged EXEC command.
Setting a maximum number of addresses to one and configuring the MAC address of an attached device ensures that the device has the full bandwidth of the port.
When you enter a maximum secure address value for an interface, this occurs:
•If the new value is greater than the previous value, the new value overrides the previously configured value.
•If the new value is less than the previous value and the number of configured secure addresses on the interface exceeds the new value, the command is rejected.
Sticky secure MAC addresses have these characteristics:
•When you enable sticky learning on an interface by using the switchport port-security mac-address sticky interface configuration command, the interface converts all the dynamic secure MAC addresses, including those that were dynamically learned before sticky learning was enabled, to sticky secure MAC addresses and adds all sticky secure MAC addresses to the running configuration.
•If you disable sticky learning by using the no switchport port-security mac-address sticky interface configuration command or the running configuration is removed, the sticky secure MAC addresses remain part of the running configuration but are removed from the address table. The addresses that were removed can be dynamically reconfigured and added to the address table as dynamic addresses.
•When you configure sticky secure MAC addresses by using the switchport port-security mac-address sticky mac-address interface configuration command, these addresses are added to the address table and the running configuration. If port security is disabled, the sticky secure MAC addresses remain in the running configuration.
•If you save the sticky secure MAC addresses in the configuration file, when the switch restarts or the interface shuts down, the interface does not need to relearn these addresses. If you do not save the sticky secure addresses, they are lost. If sticky learning is disabled, the sticky secure MAC addresses are converted to dynamic secure addresses and are removed from the running configuration.
•If you disable sticky learning and enter the switchport port-security mac-address sticky mac-address interface configuration command, an error message appears, and the sticky secure MAC address is not added to the running configuration.
Examples
This example shows how to enable port security on a port and to set the maximum number of secure addresses to 5. The violation mode is the default, and no secure MAC addresses are configured.
Switch(config)# interface gigabitethernet 0/2
Switch(config-if)# switchport mode access
Switch(config-if)# switchport port-security
Switch(config-if)# switchport port-security maximum 5
This example shows how to configure a secure MAC address and a VLAN ID on a port:
Switch(config)# interface gigabitethernet 0/2
Switch(config-if)# switchport mode trunk
Switch(config-if)# switchport port-security
Switch(config-if)# switchport port-security mac-address 1000.2000.3000 vlan 3
This example shows how to enable sticky learning and to enter two sticky secure MAC addresses on a port:
Switch(config)# interface gigabitethernet 0/2
Switch(config-if)# switchport port-security mac-address sticky
Switch(config-if)# switchport port-security mac-address sticky 0000.0000.4141
Switch(config-if)# switchport port-security mac-address sticky 0000.0000.000f
This example show how to configure a port to shut down only the VLAN if a violation occurs:
Switch(config)# interface gigabitethernet 2/0/2
Switch(config)# switchport port-security violation shutdown vlan
You can verify your settings by using the show port-security privileged EXEC command.
Related Commands
|
|
---|---|
Deletes from the MAC address table a specific type of secure address or all the secure addresses on the switch or an interface. |
|
show port-security address |
Displays all the secure addresses configured on the switch. |
show port-security |
Displays port security configuration for the switch or for the specified interface. |
switchport port-security aging
Use the switchport port-security aging interface configuration command to set the aging time and type for secure address entries or to change the aging behavior for secure addresses on a particular port. Use the no form of this command to disable port security aging or to set the parameters to their default states.
switchport port-security aging {static | time time | type {absolute | inactivity}}
no switchport port-security aging {static | time | type}
Syntax Description
Defaults
The port security aging feature is disabled. The default time is 0 minutes.
The default aging type is absolute.
The default static aging behavior is disabled.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
To enable secure address aging for a particular port, set the aging time to a value other than 0 for that port.
To allow limited time access to particular secure addresses, set the aging type as absolute. When the aging time lapses, the secure addresses are deleted.
To allow continuous access to a limited number of secure addresses, set the aging type as inactivity. This removes the secure address when it become inactive, and other addresses can become secure.
To allow unlimited access to a secure address, configure it as a secure address, and disable aging for the statically configured secure address by using the no switchport port-security aging static interface configuration command.
Examples
This example sets the aging time as 2 hours for absolute aging for all the secure addresses on the port:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# switchport port-security aging time 120
This example sets the aging time as 2 minutes for inactivity aging type with aging enabled for configured secure addresses on the port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# switchport port-security aging time 2
Switch(config-if)# switchport port-security aging type inactivity
Switch(config-if)# switchport port-security aging static
This example shows how to disable aging for configured secure addresses:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# no switchport port-security aging static
Related Commands
switchport protected
Use the switchport protected interface configuration command to isolate unicast, multicast, and broadcast traffic at Layer 2 from other protected ports on the same switch. Use the no form of this command to disable protection on the port.
switchport protected
no switchport protected
Syntax Description
This command has no arguments or keywords.
Defaults
No protected port is defined. All ports are nonprotected.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The switchport protection feature is local to the switch; communication between protected ports on the same switch is possible only through a Layer 3 device. To prevent communication between protected ports on different switches, you must configure the protected ports for unique VLANs on each switch and configure a trunk link between the switches. A protected port is different from a secure port.
A protected port does not forward any traffic (unicast, multicast, or broadcast) to any other port that is also a protected port. Data traffic cannot be forwarded between protected ports at Layer 2; only control traffic, such as PIM packets, is forwarded because these packets are processed by the CPU and forwarded in software. All data traffic passing between protected ports must be forwarded through a Layer 3 device.
Port monitoring does not work if both the monitor and monitored ports are protected ports.
Examples
This example shows how to enable a protected port on an interface:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# switchport protected
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including port blocking and port protection settings. |
Prevents unknown multicast or unicast traffic on the interface. |
switchport trunk
Use the switchport trunk interface configuration command to set the trunk characteristics when the interface is in trunking mode. Use the no form of this command to reset a trunking characteristic to the default.
switchport trunk {allowed vlan vlan-list | native vlan vlan-id | pruning vlan vlan-list}
no switchport trunk {allowed vlan | native vlan | {pruning vlan}
Syntax Description
The vlan-list format is all | none | [add | remove | except] vlan-atom [,vlan-atom...] where:
•all specifies all VLANs from 1 to 4094. This keyword is not allowed on commands that do not permit all VLANs in the list to be set at the same time.
•none means an empty list. This keyword is not allowed on commands that require certain VLANs to be set or at least one VLAN to be set.
•add adds the defined list of VLANs to those currently set instead of replacing the list. Valid IDs are from 1 to 1005; extended-range VLANs (VLAN IDs greater than 1005) are valid in some cases.
Note You can add extended-range VLANs to the allowed VLAN list, but not to the pruning-eligible VLAN list.
Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs.
•remove removes the defined list of VLANs from those currently set instead of replacing the list. Valid IDs are from 1 to 1005; extended-range VLAN IDs are valid in some cases.
Note You can remove extended-range VLANs from the allowed VLAN list, but you cannot remove them from the pruning-eligible list.
Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs.
•except lists the VLANs that should be calculated by inverting the defined list of VLANs. (VLANs are added except the ones specified.) Valid IDs are from 1 to 1005. Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs.
•vlan-atom is either a single VLAN number from 1 to 4094 or a continuous range of VLANs described by two VLAN numbers, the lesser one first, separated by a hyphen.
Defaults
VLAN 1 is the default native VLAN ID on the port.
The default for all VLAN lists is to include all VLANs.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Native VLANs:
•All untagged traffic received on an IEEE 802.1Q trunk port is forwarded with the native VLAN configured for the port.
•If a packet has a VLAN ID that is the same as the sending-port native VLAN ID, the packet is sent without a tag; otherwise, the switch sends the packet with a tag.
•The no form of the native vlan command resets the native mode VLAN to the appropriate default VLAN for the device.
Allowed VLAN:
•To reduce the risk of spanning-tree loops or storms, you can disable VLAN 1 on any individual VLAN trunk port by removing VLAN 1 from the allowed list. When you remove VLAN 1 from a trunk port, the interface continues to send and receive management traffic, for example, Cisco Discovery Protocol (CDP), Port Aggregation Protocol (PAgP), Link Aggregation Control Protocol (LACP), Dynamic Trunking Protocol (DTP), and VLAN Trunking Protocol (VTP) in VLAN 1.
•The no form of the allowed vlan command resets the list to the default list, which allows all VLANs.
Trunk pruning:
•The pruning-eligible list applies only to trunk ports.
•Each trunk port has its own eligibility list.
•If you do not want a VLAN to be pruned, remove it from the pruning-eligible list. VLANs that are pruning-ineligible receive flooded traffic.
•VLAN 1, VLANs 1002 to 1005, and extended-range VLANs (VLANs 1006 to 4094) cannot be pruned.
Examples
This example shows how to configure VLAN 3 as the default for the port to send all untagged traffic:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# switchport trunk native vlan 3
This example shows how to add VLANs 1, 2, 5, and 6 to the allowed list:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# switchport trunk allowed vlan add 1,2,5,6
This example shows how to remove VLANs 3 and 10 to 15 from the pruning-eligible list:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# switchport trunk pruning vlan remove 3,10-15
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
---|---|
show interfaces switchport |
Displays the administrative and operational status of a switching port, including port blocking and port protection settings. |
Configures the VLAN membership mode of a port. |
switchport voice detect
Use the switchport voice detect interface configuration command on the switch stack or on a standalone switch to detect and recognize a Cisco IP phone. Use the no form of this command to return to the default setting.
switchport voice detect cisco-phone [full-duplex]
no switchport voice detect cisco-phone [full-duplex]
Syntax Description
cisco-phone |
Configure the switch to detect and recognize a Cisco IP phone. |
full-duplex |
(optional) Configure the switch to only accept a full-duplex Cisco IP phone. |
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Use this command to detect and recognize a Cisco IP phone.
Examples
This example shows how to enable switchport voice detect on the switch:
Switch(config)# interface fastethernet 0/1
Switch(config-if)# switchport voice detect cisco-phone
This example shows how to disable switchport voice detect on the switch:
Switch(config)# interface fastethernet 0/1
Switch(config-if)# no switchport voice detect cisco-phone
You can verify your settings by entering the show run interfaces interface-id privileged EXEC command.
switchport voice vlan
Use the switchport voice vlan interface configuration command to configure voice VLAN on the port. Use the no form of this command to return to the default setting.
switchport voice vlan {vlan-id | dot1p | none | untagged}
no switchport voice vlan
Syntax Description
Defaults
The switch default is not to automatically configure the telephone (none).
The telephone default is not to tag frames.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You should configure voice VLAN on Layer 2 access ports.
You must enable Cisco Discovery Protocol (CDP) on the switchport connected to the Cisco IP phone for the switch to send configuration information to the phone. CDP is enabled by default globally and on the interface.
Before you enable voice VLAN, we recommend that you enable quality of service (QoS) on the switch by entering the mls qos global configuration command and configure the port trust state to trust by entering the mls qos trust cos interface configuration command.
When you enter a VLAN ID, the IP phone forwards voice traffic in IEEE 802.1Q frames, tagged with the specified VLAN ID. The switch puts IEEE 802.1Q voice traffic in the voice VLAN.
When you select dot1q, none, or untagged, the switch puts the indicated voice traffic in the access VLAN.
In all configurations, the voice traffic carries a Layer 2 IP precedence value. The default is 5 for voice traffic.
When you enable port security on an interface that is also configured with a voice VLAN, set the maximum allowed secure addresses on the port to two. When the port is connected to a Cisco IP phone, the IP phone requires one MAC address. The Cisco IP phone address is learned on the voice VLAN, but is not learned on the access VLAN. If you connect a single PC to the Cisco IP phone, no additional MAC addresses are required. If you connect more than one PC to the Cisco IP phone, you must configure enough secure addresses to allow one for each PC and one for the Cisco IP phone.
If any type of port security is enabled on the access VLAN, dynamic port security is automatically enabled on the voice VLAN.
You cannot configure static secure MAC addresses in the voice VLAN.
The Port Fast feature is automatically enabled when voice VLAN is configured. When you disable voice VLAN, the Port Fast feature is not automatically disabled.
Examples
This example shows how to configure VLAN 2 as the voice VLAN for the port:
Switch(config)# interface gigabitethernet0/2
Switch(config-if)# switchport voice vlan 2
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
---|---|
show interfaces interface-id switchport |
Displays the administrative and operational status of a switching port. |
system mtu
Use the system mtu global configuration command to set the maximum packet size or maximum transmission unit (MTU) size for Gigabit Ethernet ports or for Fast Ethernet (10/100) ports. Use the no form of this command to restore the global MTU value to its default value.
system mtu {bytes | jumbo bytes}
no system mtu
Syntax Description
Defaults
The default MTU size for all ports is 1500 bytes.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
When you use this command to change the system MTU or jumbo MTU size, you must reset the switch before the new configuration takes effect.The system MTU setting is saved in the switch environmental variable in NVRAM and becomes effective when the switch reloads. The MTU settings you enter with the system mtu and system mtu jumbo commands are not saved in the switch IOS configuration file, even if you enter the copy running-config startup-config privileged EXEC command. Therefore, if you use TFTP to configure a new switch by using a backup configuration file and want the system MTU to be other than the default, you must explicitly configure the system mtu and system mtu jumbo settings on the new switch and then reload the switch.
Gigabit Ethernet ports operating at 1000 Mb/s are not affected by the system mtu command, and 10/100-Mb/s ports are not affected by the system mtu jumbo command.
If you enter a value that is outside the range for the specific type of switch, the value is not accepted.
Note The switch does not support setting the MTU on a per-interface basis.
The size of frames that can be received by the switch CPU is limited to 1998 bytes, regardless of the value entered with the system mtu command. Although forwarded or routed frames are usually not received by the CPU, some packets (for example, control traffic, SNMP, Telnet, and routing protocols) are sent to the CPU.
For example, if the system mtu value is 1998 bytes and the system mtu jumbo value is 5000 bytes, packets up to 5000 bytes can be received on interfaces operating at 1000 Mb/s. However, although a packet larger than 1998 bytes can be received on an interface operating at 1000 Mb/s, if its destination interface is operating at 10 or 100 Mb/s, the packet is dropped.
Examples
This example shows how to set the maximum jumbo packet size for Gigabit Ethernet ports operating at 1000 Mb/s or greater to 1800 bytes:
Switch(config)# system mtu jumbo 1800
Switch(config)# exit
Switch# reload
You can verify your setting by entering the show system mtu privileged EXEC command.
Related Commands
|
|
---|---|
Displays the packet size set for Fast Ethernet and Gigabit Ethernet ports. |
test cable-diagnostics tdr
Use the test cable-diagnostics tdr privileged EXEC command to run the Time Domain Reflector (TDR) feature on an interface.
test cable-diagnostics tdr interface interface-id
Syntax Description
interface-id |
Specify the interface on which to run TDR. |
Defaults
There is no default.
Command Modes
Privileged EXEC
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
TDR is supported only on 10/100 and 10/100/1000 copper Ethernet ports. It is not supported on SFP module ports. For more information about TDR, see the software configuration guide for this release.
After you run TDR by using the test cable-diagnostics tdr interface interface-id command, use the show cable-diagnostics tdr interface interface-id privileged EXEC command to display the results.
Examples
This example shows how to run TDR on an interface:
Switch# test cable-diagnostics tdr interface gigabitethernet0/2
TDR test started on interface Gi0/2
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
If you enter the test cable-diagnostics tdr interface interface-id command on an interface that has a link status of up and a speed of 10 or 100 Mb/s, these messages appear:
Switch# test cable-diagnostics tdr interface gigabitethernet0/3
TDR test on Gi0/9 will affect link state and traffic
TDR test started on interface Gi0/3
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
Related Commands
|
|
---|---|
Displays the TDR results. |
traceroute mac
Use the traceroute mac privileged EXEC command to display the Layer 2 path taken by the packets from the specified source MAC address to the specified destination MAC address.
traceroute mac [interface interface-id] {source-mac-address} [interface interface-id] {destination-mac-address} [vlan vlan-id] [detail]
Syntax Description
Defaults
There is no default.
Command Modes
Privileged EXEC
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
For Layer 2 traceroute to function properly, Cisco Discovery Protocol (CDP) must be enabled on all the switches in the network. Do not disable CDP.
When the switch detects a device in the Layer 2 path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
The maximum number of hops identified in the path is ten.
Layer 2 traceroute supports only unicast traffic. If you specify a multicast source or destination MAC address, the physical path is not identified, and an error message appears.
The traceroute mac command output shows the Layer 2 path when the specified source and destination addresses belong to the same VLAN. If you specify source and destination addresses that belong to different VLANs, the Layer 2 path is not identified, and an error message appears.
If the source or destination MAC address belongs to multiple VLANs, you must specify the VLAN to which both the source and destination MAC addresses belong. If the VLAN is not specified, the path is not identified, and an error message appears.
The Layer 2 traceroute feature is not supported when multiple devices are attached to one port through hubs (for example, multiple CDP neighbors are detected on a port). When more than one CDP neighbor is detected on a port, the Layer 2 path is not identified, and an error message appears.
This feature is not supported in Token Ring VLANs.
Examples
This example shows how to display the Layer 2 path by specifying the source and destination MAC addresses:
Switch# traceroute mac 0000.0201.0601 0000.0201.0201
Source 0000.0201.0601 found on con6[WS-C2960-12T] (2.2.6.6)
con6 (2.2.6.6) :Gi0/1 => Gi0/3
con5 (2.2.5.5 ) : Gi0/3 => Gi0/1
con1 (2.2.1.1 ) : Gi0/1 => Gi0/2
con2 (2.2.2.2 ) : Gi0/2 => Gi0/1
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
Layer 2 trace completed
This example shows how to display the Layer 2 path by using the detail keyword:
Switch# traceroute mac 0000.0201.0601 0000.0201.0201 detail
Source 0000.0201.0601 found on con6[WS-C2960-12T] (2.2.6.6)
C-12T / 2.2.6.6 :
Gi0/2 [auto, auto] => Gi0/3 [auto, auto]
con5 / WS-C2950G-24-EI / 2.2.5.5 :
Fa0/3 [auto, auto] => Gi0/1 [auto, auto]
con1 / WS-C3550-12G / 2.2.1.1 :
Gi0/1 [auto, auto] => Gi0/2 [auto, auto]
con2 / WS-C3550-24 / 2.2.2.2 :
Gi0/2 [auto, auto] => Fa0/1 [auto, auto]
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
Layer 2 trace completed.
This example shows how to display the Layer 2 path by specifying the interfaces on the source and destination switches:
Switch# traceroute mac interface fastethernet0/1 0000.0201.0601 interface fastethernet0/3
0000.0201.0201
Source 0000.0201.0601 found on con6[WS-C2960-12T] (2.2.6.6)
con6 (2.2.6.6) :Gi0/1 => Gi0/3
con5 (2.2.5.5 ) : Gi0/3 => Gi0/1
con1 (2.2.1.1 ) : Gi0/1 => Gi0/2
con2 (2.2.2.2 ) : Gi0/2 => Gi0/1
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
Layer 2 trace completed
This example shows the Layer 2 path when the switch is not connected to the source switch:
Switch# traceroute mac 0000.0201.0501 0000.0201.0201 detail
Source not directly connected, tracing source .....
Source 0000.0201.0501 found on con5[WS-C2960-12T] (2.2.5.5)
con5 / WS-C2960-12T / 2.2.5.5 :
Gi0/1 [auto, auto] => Gi0/3 [auto, auto]
con1 / WS-C3550-12G / 2.2.1.1 :
Gi0/1 [auto, auto] => Gi0/2 [auto, auto]
con2 / WS-C3550-24 / 2.2.2.2 :
Gi0/2 [auto, auto] => Fa0/1 [auto, auto]
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
Layer 2 trace completed.
This example shows the Layer 2 path when the switch cannot find the destination port for the source MAC address:
Switch# traceroute mac 0000.0011.1111 0000.0201.0201
Error:Source Mac address not found.
Layer2 trace aborted.
This example shows the Layer 2 path when the source and destination devices are in different VLANs:
Switch# traceroute mac 0000.0201.0601 0000.0301.0201
Error:Source and destination macs are on different vlans.
Layer2 trace aborted.
This example shows the Layer 2 path when the destination MAC address is a multicast address:
Switch# traceroute mac 0000.0201.0601 0100.0201.0201
Invalid destination mac address
This example shows the Layer 2 path when source and destination switches belong to multiple VLANs:
Switch# traceroute mac 0000.0201.0601 0000.0201.0201
Error:Mac found on multiple vlans.
Layer2 trace aborted.
Related Commands
|
|
---|---|
Displays the Layer 2 path taken by the packets from the specified source IP address or hostname to the specified destination IP address or hostname. |
traceroute mac ip
Use the traceroute mac ip privileged EXEC command to display the Layer 2 path taken by the packets from the specified source IP address or hostname to the specified destination IP address or hostname.
traceroute mac ip {source-ip-address | source-hostname} {destination-ip-address | destination-hostname} [detail]
Syntax Description
Defaults
There is no default.
Command Modes
Privileged EXEC
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
For Layer 2 traceroute to function properly, Cisco Discovery Protocol (CDP) must be enabled on all the switches in the network. Do not disable CDP.
When the switch detects an device in the Layer 2 path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
The maximum number of hops identified in the path is ten.
The traceroute mac ip command output shows the Layer 2 path when the specified source and destination IP addresses are in the same subnet. When you specify the IP addresses, the switch uses Address Resolution Protocol (ARP) to associate the IP addresses with the corresponding MAC addresses and the VLAN IDs.
•If an ARP entry exists for the specified IP address, the switch uses the associated MAC address and identifies the physical path.
•If an ARP entry does not exist, the switch sends an ARP query and tries to resolve the IP address. The IP addresses must be in the same subnet. If the IP address is not resolved, the path is not identified, and an error message appears.
The Layer 2 traceroute feature is not supported when multiple devices are attached to one port through hubs (for example, multiple CDP neighbors are detected on a port). When more than one CDP neighbor is detected on a port, the Layer 2 path is not identified, and an error message appears.
This feature is not supported in Token Ring VLANs.
Examples
This example shows how to display the Layer 2 path by specifying the source and destination IP addresses and by using the detail keyword:
Switch# traceroute mac ip 2.2.66.66 2.2.22.22 detail
Translating IP to mac .....
2.2.66.66 => 0000.0201.0601
2.2.22.22 => 0000.0201.0201
Source 0000.0201.0601 found on con6[WS-C2950G-24-EI] (2.2.6.6)
con6 / WS-C2960-12T / 2.2.6.6 :
Gi0/1 [auto, auto] => Gi0/3 [auto, auto]
con5 / WS-C2950G-24-EI / 2.2.5.5 :
Fa0/3 [auto, auto] => Gi0/1 [auto, auto]
con1 / WS-C3550-12G / 2.2.1.1 :
Gi0/1 [auto, auto] => Gi0/2 [auto, auto]
con2 / WS-C3550-24 / 2.2.2.2 :
Gi0/2 [auto, auto] => Fa0/1 [auto, auto]
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
Layer 2 trace completed.
This example shows how to display the Layer 2 path by specifying the source and destination hostnames:
Switch# traceroute mac ip con6 con2
Translating IP to mac .....
2.2.66.66 => 0000.0201.0601
2.2.22.22 => 0000.0201.0201
Source 0000.0201.0601 found on con6
con6 (2.2.6.6) :Gi0/1 => Gi0/3
con5 (2.2.5.5 ) : Gi0/3 => Gi0/1
con1 (2.2.1.1 ) : Gi0/1 => Gi0/2
con2 (2.2.2.2 ) : Gi0/2 => Fa0/1
Destination 0000.0201.0201 found on con2
Layer 2 trace completed
This example shows the Layer 2 path when ARP cannot associate the source IP address with the corresponding MAC address:
Switch# traceroute mac ip 2.2.66.66 2.2.77.77
Arp failed for destination 2.2.77.77.
Layer2 trace aborted.
Related Commands
|
|
---|---|
Displays the Layer 2 path taken by the packets from the specified source MAC address to the specified destination MAC address. |
trust
Use the trust policy-map class configuration command to define a trust state for traffic classified through the class policy-map configuration or the class-map global configuration command. Use the no form of this command to return to the default setting.
trust [cos | dscp | ip-precedence]
no trust [cos | dscp | ip-precedence]
Syntax Description
Defaults
The action is not trusted. If no keyword is specified when the command is entered, the default is dscp.
Command Modes
Policy-map class configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
Use this command to distinguish the quality of service (QoS) trust behavior for certain traffic from other traffic. For example, incoming traffic with certain DSCP values can be trusted. You can configure a class map to match and trust the DSCP values in the incoming traffic.
Trust values set with this command supersede trust values set with the mls qos trust interface configuration command.
The trust command is mutually exclusive with set policy-map class configuration command within the same policy map.
If you specify trust cos, QoS uses the received or default port CoS value and the CoS-to-DSCP map to generate a DSCP value for the packet.
If you specify trust dscp, QoS uses the DSCP value from the ingress packet. For non-IP packets that are tagged, QoS uses the received CoS value; for non-IP packets that are untagged, QoS uses the default port CoS value. In either case, the DSCP value for the packet is derived from the CoS-to-DSCP map.
If you specify trust ip-precedence, QoS uses the IP precedence value from the ingress packet and the IP-precedence-to-DSCP map. For non-IP packets that are tagged, QoS uses the received CoS value; for non-IP packets that are untagged, QoS uses the default port CoS value. In either case, the DSCP for the packet is derived from the CoS-to-DSCP map.
To return to policy-map configuration mode, use the exit command. To return to privileged EXEC mode, use the end command.
Examples
This example shows how to define a port trust state to trust incoming DSCP values for traffic classified with class1:
Switch(config)# policy-map policy1
Switch(config-pmap)# class class1
Switch(config-pmap-c)# trust dscp
Switch(config-pmap-c)# police 1000000 20000 exceed-action policed-dscp-transmit
Switch(config-pmap-c)# exit
You can verify your settings by entering the show policy-map privileged EXEC command.
Related Commands
|
|
---|---|
Classifies IP traffic by setting a DSCP or IP-precedence value in the packet. |
|
Displays QoS policy maps. |
udld
Use the udld global configuration command to enable aggressive or normal mode in the UniDirectional Link Detection (UDLD) and to set the configurable message timer time. Use the no form of the command to disable aggressive or normal mode UDLD on all fiber-optic ports.
udld {aggressive | enable | message time message-timer-interval}
no udld {aggressive | enable | message}
Syntax Description
Defaults
UDLD is disabled on all interfaces.
The message timer is set at 60 seconds.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
UDLD supports two modes of operation: normal (the default) and aggressive. In normal mode, UDLD detects unidirectional links due to misconnected interfaces on fiber-optic connections. In aggressive mode, UDLD also detects unidirectional links due to one-way traffic on fiber-optic and twisted-pair links and due to misconnected interfaces on fiber-optic links. For information about normal and aggressive modes, see the "Understanding UDLD" section in the software configuration guide for this release.
If you change the message time between probe packets, you are making a trade-off between the detection speed and the CPU load. By decreasing the time, you can make the detection-response faster but increase the load on the CPU.
This command affects fiber-optic interfaces only. Use the udld interface configuration command to enable UDLD on other interface types.
You can use these commands to reset an interface shut down by UDLD:
•The udld reset privileged EXEC command to reset all interfaces shut down by UDLD
•The shutdown and no shutdown interface configuration commands
•The no udld enable global configuration command followed by the udld {aggressive | enable} global configuration command to re-enable UDLD globally
•The no udld port interface configuration command followed by the udld port or udld port aggressive interface configuration command to re-enable UDLD on the specified interface
•The errdisable recovery cause udld and errdisable recovery interval interval global configuration commands to automatically recover from the UDLD error-disabled state
Examples
This example shows how to enable UDLD on all fiber-optic interfaces:
Switch(config)# udld enable
You can verify your setting by entering the show udld privileged EXEC command.
Related Commands
udld port
Use the udld port interface configuration command to enable the UniDirectional Link Detection (UDLD) on an individual interface or prevent a fiber-optic interface from being enabled by the udld global configuration command. Use the no form of this command to return to the udld global configuration command setting or to disable UDLD if entered for a nonfiber-optic port.
udld port [aggressive]
no udld port [aggressive]
Syntax Description
aggressive |
Enable UDLD in aggressive mode on the specified interface. |
Defaults
On fiber-optic interfaces, UDLD is not enabled, not in aggressive mode, and not disabled. For this reason, fiber-optic interfaces enable UDLD according to the state of the udld enable or udld aggressive global configuration command.
On nonfiber-optic interfaces, UDLD is disabled.
Command Modes
Interface configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
A UDLD-capable port cannot detect a unidirectional link if it is connected to a UDLD-incapable port of another switch.
UDLD supports two modes of operation: normal (the default) and aggressive. In normal mode, UDLD detects unidirectional links due to misconnected interfaces on fiber-optic connections. In aggressive mode, UDLD also detects unidirectional links due to one-way traffic on fiber-optic and twisted-pair links and due to misconnected interfaces on fiber-optic links. For information about normal and aggressive modes, see the "Configuring UDLD" chapter in the software configuration guide for this release.
To enable UDLD in normal mode, use the udld port interface configuration command. To enable UDLD in aggressive mode, use the udld port aggressive interface configuration command.
Use the no udld port command on fiber-optic ports to return control of UDLD to the udld enable global configuration command or to disable UDLD on nonfiber-optic ports.
Use the udld port aggressive command on fiber-optic ports to override the setting of the udld enable or udld aggressive global configuration command. Use the no form on fiber-optic ports to remove this setting and to return control of UDLD enabling to the udld global configuration command or to disable UDLD on nonfiber-optic ports.
You can use these commands to reset an interface shut down by UDLD:
•The udld reset privileged EXEC command to reset all interfaces shut down by UDLD
•The shutdown and no shutdown interface configuration commands
•The no udld enable global configuration command followed by the udld {aggressive | enable} global configuration command to re-enable UDLD globally
•The no udld port interface configuration command followed by the udld port or udld port aggressive interface configuration command to re-enable UDLD on the specified interface
•The errdisable recovery cause udld and errdisable recovery interval interval global configuration commands to automatically recover from the UDLD error-disabled state
Examples
This example shows how to enable UDLD on an port:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# udld port
This example shows how to disable UDLD on a fiber-optic interface despite the setting of the udld global configuration command:
Switch(config)# interface gigabitethernet0/1
Switch(config-if)# no udld port
You can verify your settings by entering the show running-config or the show udld interface privileged EXEC command.
Related Commands
udld reset
Use the udld reset privileged EXEC command to reset all interfaces disabled by the UniDirectional Link Detection (UDLD) and permit traffic to begin passing through them again (though other features, such as spanning tree, Port Aggregation Protocol (PAgP), and Dynamic Trunking Protocol (DTP) still have their normal effects, if enabled).
udld reset
Syntax Description
This command has no arguments or keywords.
Command Modes
Privileged EXEC
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
If the interface configuration is still enabled for UDLD, these ports begin to run UDLD again and are disabled for the same reason if the problem has not been corrected.
Examples
This example shows how to reset all interfaces disabled by UDLD:
Switch# udld reset
1 ports shutdown by UDLD were reset.
You can verify your setting by entering the show udld privileged EXEC command.
Related Commands
vlan (global configuration)
Use the vlan global configuration command to add a VLAN and to enter the config-vlan mode. Use the no form of this command to delete the VLAN. Configuration information for normal-range VLANs (VLAN IDs 1 to 1005) is always saved in the VLAN database. When VLAN Trunking Protocol (VTP) mode is transparent, you can create extended-range VLANs (VLAN IDs greater than 1005), and the VTP mode, domain name, and the VLAN configuration are saved in the switch running configuration file. You can save configurations in the switch startup configuration file by entering the copy running-config startup-config privileged EXEC command.
vlan vlan-id
no vlan vlan-id
Syntax Description
Defaults
This command has no default settings.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You must use the vlan vlan-id global configuration command to add extended-range VLANs (VLAN IDs 1006 to 4094). Before configuring VLANs in the extended range, you must use the vtp transparent global configuration or VLAN configuration command to put the switch in VTP transparent mode. Extended-range VLANs are not learned by VTP and are not added to the VLAN database, but when VTP mode is transparent, VTP mode and domain name and all VLAN configurations are saved in the running configuration, and you can save them in the switch startup configuration file.
When you save the VLAN and VTP configurations in the startup configuration file and reboot the switch, the configuration is selected in these ways:
•If both the VLAN database and the configuration file show the VTP mode as transparent and the VTP domain names match, the VLAN database is ignored. The VTP and VLAN configurations in the startup configuration file are used. The VLAN database revision number remains unchanged in the VLAN database.
•If the VTP mode is server, or if the startup VTP mode or domain names do not match the VLAN database, the VTP mode and the VLAN configuration for the first 1005 VLANs use the VLAN database information.
If you try to create an extended-range VLAN when the switch is not in VTP transparent mode, the VLAN is rejected, and you receive an error message.
If you enter an invalid VLAN ID, you receive an error message and do not enter config-vlan mode.
Entering the vlan command with a VLAN ID enables config-vlan mode. When you enter the VLAN ID of an existing VLAN, you do not create a new VLAN, but you can modify VLAN parameters for that VLAN. The specified VLANs are added or modified when you exit the config-vlan mode. Only the shutdown command (for VLANs 1 to 1005) takes effect immediately.
These configuration commands are available in config-vlan mode. The no form of each command returns the characteristic to its default state.
Note Although all commands are visible, the only VLAN configuration commands that are supported on extended-range VLANs are mtu mtu-size and remote-span. For extended-range VLANs, all other characteristics must remain at the default state.
•are are-number: defines the maximum number of all-routes explorer (ARE) hops for this VLAN. This keyword applies only to TrCRF VLANs.The range is 0 to 13. The default is 7. If no value is entered, 0 is assumed to be the maximum.
•backupcrf: specifies the backup CRF mode. This keyword applies only to TrCRF VLANs.
–enable backup CRF mode for this VLAN.
–disable backup CRF mode for this VLAN (the default).
•bridge {bridge-number| type}: specifies the logical distributed source-routing bridge, the bridge that interconnects all logical rings having this VLAN as a parent VLAN in FDDI-NET, Token Ring-NET, and TrBRF VLANs. The range is 0 to 15. The default bridge number is 0 (no source-routing bridge) for FDDI-NET, TrBRF, and Token Ring-NET VLANs. The type keyword applies only to TrCRF VLANs and is one of these:
–srb (source-route bridging)
–srt (source-route transparent) bridging VLAN
•exit: applies changes, increments the VLAN database revision number (VLANs 1 to 1005 only), and exits config-vlan mode.
•media: defines the VLAN media type. See Table 2-21 for valid commands and syntax for different media types.
Note The switch supports only Ethernet ports. You configure only FDDI and Token Ring media-specific characteristics for VLAN Trunking Protocol (VTP) global advertisements to other switches. These VLANs are locally suspended.
–ethernet is Ethernet media type (the default).
–fddi is FDDI media type.
–fd-net is FDDI network entity title (NET) media type.
–tokenring is Token Ring media type if the VTP v2 mode is disabled, or TrCRF if the VTP Version 2 (v) mode is enabled.
–tr-net is Token Ring network entity title (NET) media type if the VTP v2 mode is disabled or TrBRF media type if the VTP v2 mode is enabled.
•mtu mtu-size: specifies the maximum transmission unit (MTU) (packet size in bytes). The range is 1500 to 18190. The default is 1500 bytes.
•name vlan-name: names the VLAN with an ASCII string from 1 to 32 characters that must be unique within the administrative domain. The default is VLANxxxx where xxxx represents four numeric digits (including leading zeros) equal to the VLAN ID number.
•no: negates a command or returns it to the default setting.
•parent parent-vlan-id: specifies the parent VLAN of an existing FDDI, Token Ring, or TrCRF VLAN. This parameter identifies the TrBRF to which a TrCRF belongs and is required when defining a TrCRF. The range is 0 to 1005. The default parent VLAN ID is 0 (no parent VLAN) for FDDI and Token Ring VLANs. For both Token Ring and TrCRF VLANs, the parent VLAN ID must already exist in the database and be associated with a Token Ring-NET or TrBRF VLAN.
•remote-span: configure the VLAN as a Remote SPAN (RSPAN) VLAN. When the RSPAN feature is added to an existing VLAN, the VLAN is first deleted and is then recreated with the RSPAN feature. Any access ports are deactivated until the RSPAN feature is removed. If VTP is enabled, the new RSPAN VLAN is propagated by VTP for VLAN-IDs that are lower than 1024. Learning is disabled on the VLAN.
•ring ring-number: defines the logical ring for an FDDI, Token Ring, or TrCRF VLAN. The range is 1 to 4095. The default for Token Ring VLANs is 0. For FDDI VLANs, there is no default.
•said said-value: specifies the security association identifier (SAID) as documented in IEEE 802.10. The range is 1 to 4294967294, and the number must be unique within the administrative domain. The default value is 100000 plus the VLAN ID number.
•shutdown: shuts down VLAN switching on the VLAN. This command takes effect immediately. Other commands take effect when you exit config-vlan mode.
•state: specifies the VLAN state:
–active means the VLAN is operational (the default).
–suspend means the VLAN is suspended. Suspended VLANs do not pass packets.
•ste ste-number: defines the maximum number of spanning-tree explorer (STE) hops. This keyword applies only to TrCRF VLANs. The range is 0 to 13. The default is 7.
•stp type: defines the spanning-tree type for FDDI-NET, Token Ring-NET, or TrBRF VLANs. For FDDI-NET VLANs, the default STP type is ieee. For Token Ring-NET VLANs, the default STP type is ibm. For FDDI and Token Ring VLANs, the default is no type specified.
–ieee for IEEE Ethernet STP running source-route transparent (SRT) bridging.
–ibm for IBM STP running source-route bridging (SRB).
–auto for STP running a combination of source-route transparent bridging (IEEE) and source-route bridging (IBM).
•tb-vlan1 tb-vlan1-id and tb-vlan2 tb-vlan2-id: specifies the first and second VLAN to which this VLAN is translationally bridged. Translational VLANs translate FDDI or Token Ring to Ethernet, for example. The range is 0 to 1005. If no value is specified, 0 (no transitional bridging) is assumed.
Table 2-22 describes the rules for configuring VLANs.
Examples
This example shows how to add an Ethernet VLAN with default media characteristics. The default includes a vlan-name of VLANxxx, where xxxx represents four numeric digits (including leading zeros) equal to the VLAN ID number. The default media option is ethernet; the state option is active. The default said-value variable is 100000 plus the VLAN ID; the mtu-size variable is 1500; the stp-type option is ieee. When you enter the exit config-vlan configuration command, the VLAN is added if it did not already exist; otherwise, this command does nothing.
This example shows how to create a new VLAN with all default characteristics and enter config-vlan mode:
Switch(config)# vlan 200
Switch(config-vlan)# exit
Switch(config)#
This example shows how to create a new extended-range VLAN with all the default characteristics, to enter config-vlan mode, and to save the new VLAN in the switch startup configuration file:
Switch(config)# vtp mode transparent
Switch(config)# vlan 2000
Switch(config-vlan)# end
Switch# copy running-config startup config
You can verify your setting by entering the show vlan privileged EXEC command.
Related Commands
vlan (VLAN configuration)
Use the vlan VLAN configuration command to configure VLAN characteristics for a normal-range VLAN (VLAN IDs 1 to 1005) in the VLAN database. You access VLAN configuration mode by entering the vlan database privileged EXEC command. Use the no form of this command without additional parameters to delete a VLAN. Use the no form with parameters to change its configured characteristics.
vlan vlan-id [are are-number] [backupcrf {enable | disable}] [bridge bridge-number |
type {srb | srt}] [media {ethernet | fddi | fdi-net | tokenring | tr-net}] [mtu mtu-size]
[name vlan-name] [parent parent-vlan-id] [ring ring-number] [said said-value]
[state {suspend | active}] [ste ste-number] [stp type {ieee | ibm | auto}]
[tb-vlan1 tb-vlan1-id] [tb-vlan2 tb-vlan2-id]
no vlan vlan-id [are are-number] [backupcrf {enable | disable}] [bridge bridge-number |
type {srb | srt}] [media {ethernet | fddi | fdi-net | tokenring | tr-net}] [mtu mtu-size]
[name vlan-name] [parent parent-vlan-id] [ring ring-number] [said said-value]
[state {suspend | active}] [ste ste-number] [stp type {ieee | ibm | auto}]
[tb-vlan1 tb-vlan1-id] [tb-vlan2 tb-vlan2-id]
Extended-range VLANs (with VLAN IDs from 1006 to 4094) cannot be added or modified by using these commands. To add extended-range VLANs, use the vlan (global configuration) command to enter config-vlan mode.
Note The switch supports only Ethernet ports. You configure only FDDI and Token Ring media-specific characteristics for VLAN Trunking Protocol (VTP) global advertisements to other switches. These VLANs are locally suspended.
Syntax Description
vlan-id |
ID of the configured VLAN. The range is 1 to 1005 and must be unique within the administrative domain. Do not enter leading zeros. |
are are-number |
(Optional) Specify the maximum number of all-routes explorer (ARE) hops for this VLAN. This keyword applies only to TrCRF VLANs. The range is 0 to 13. If no value is entered, 0 is assumed to be the maximum. |
backupcrf {enable | disable} |
(Optional) Specify the backup CRF mode. This keyword applies only to TrCRF VLANs. •enable backup CRF mode for this VLAN. •disable backup CRF mode for this VLAN. |
bridge bridge-number| |
(Optional) Specify the logical distributed source-routing bridge, the bridge that interconnects all logical rings having this VLAN as a parent VLAN in FDDI-NET, Token Ring-NET, and TrBRF VLANs. The range is 0 to 15. The type keyword applies only to TrCRF VLANs and is one of these: •srb (source-route bridging) •srt (source-route transparent) bridging VLAN |
media {ethernet | fddi | fd-net | tokenring | tr-net} |
(Optional) Specify the VLAN media type. Table 2-23 lists the valid syntax for each media type. •ethernet is Ethernet media type (the default). •fddi is FDDI media type. •fd-net is FDDI network entity title (NET) media type. •tokenring is Token Ring media type if the VTP v2 mode is disabled, or TrCRF if the VTP v2 mode is enabled. •tr-net is Token Ring network entity title (NET) media type if the VTP v2 mode is disabled or TrBRF media type if the VTP v2 mode is enabled. |
mtu mtu-size |
(Optional) Specify the maximum transmission unit (MTU) (packet size in bytes). The range is 1500 to 18190. |
name vlan-name |
(Optional) Specify the VLAN name, an ASCII string from 1 to 32 characters that must be unique within the administrative domain. |
parent parent-vlan-id |
(Optional) Specify the parent VLAN of an existing FDDI, Token Ring, or TrCRF VLAN. This parameter identifies the TrBRF to which a TrCRF belongs and is required when defining a TrCRF. The range is 0 to 1005. |
ring ring-number |
(Optional) Specify the logical ring for an FDDI, Token Ring, or TrCRF VLAN. The range is 1 to 4095. |
said said-value |
(Optional) Enter the security association identifier (SAID) as documented in IEEE 802.10. The range is 1 to 4294967294, and the number must be unique within the administrative domain. |
state {suspend | active} |
(Optional) Specify the VLAN state: •If active, the VLAN is operational. •If suspend, the VLAN is suspended. Suspended VLANs do not pass packets. |
ste ste-number |
(Optional) Specify the maximum number of spanning-tree explorer (STE) hops. This keyword applies only to TrCRF VLANs. The range is 0 to 13. |
stp type {ieee | ibm | auto} |
(Optional) Specify the spanning-tree type for FDDI-NET, Token Ring-NET, or TrBRF VLAN. •ieee for IEEE Ethernet STP running source-route transparent (SRT) bridging. •ibm for IBM STP running source-route bridging (SRB). •auto for STP running a combination of source-route transparent bridging (IEEE) and source-route bridging (IBM). |
tb-vlan1 tb-vlan1-id and tb-vlan2 tb-vlan2-id |
(Optional) Specify the first and second VLAN to which this VLAN is translationally bridged. Translational VLANs translate FDDI or Token Ring to Ethernet, for example. The range is 0 to 1005. Zero is assumed if no value is specified. |
Table 2-23 shows the valid syntax options for different media types.
Table 2-24 describes the rules for configuring VLANs.
Defaults
The ARE value is 7.
Backup CRF is disabled.
The bridge number is 0 (no source-routing bridge) for FDDI-NET, TrBRF, and Token Ring-NET VLANs.
The media type is ethernet.
The default mtu size is 1500 bytes.
The vlan-name variable is VLANxxxx, where xxxx represents four numeric digits (including leading zeros) equal to the VLAN ID number.
The parent VLAN ID is 0 (no parent VLAN) for FDDI and Token Ring VLANs. For TrCRF VLANs, you must specify a parent VLAN ID. For both Token Ring and TrCRF VLANs, the parent VLAN ID must already exist in the database and be associated with a Token Ring-NET or TrBRF VLAN.
The ring number for Token Ring VLANs is 0. For FDDI VLANs, there is no default.
The said value is 100000 plus the VLAN ID.
The state is active.
The STE value is 7.
The STP type is ieee for FDDI-NET and ibm for Token Ring-NET VLANs. For FDDI and Token Ring VLANs, the default is no type specified.
The tb-vlan1-id and tb-vlan2-id variables are zero (no translational bridging).
Command Modes
VLAN configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can only use this command mode for configuring normal-range VLANs, that is, VLAN IDs 1 to 1005.
Note To configure extended-range VLANs (VLAN IDs 1006 to 4094), use the vlan global configuration command.
VLAN configuration is always saved in the VLAN database. If VTP mode is transparent, it is also saved in the switch running configuration file, along with the VTP mode and domain name. You can then save it in the switch startup configuration file by using the copy running-config startup-config privileged EXEC command.
When you save VLAN and VTP configuration in the startup configuration file and reboot the switch, the configuration is selected in these ways:
•If both the VLAN database and the configuration file show the VTP mode as transparent and the VTP domain names match, the VLAN database is ignored. The VTP and VLAN configurations in the startup configuration file are used. The VLAN database revision number remains unchanged in the VLAN database.
•If the VTP mode is server, or if the startup VTP mode or domain names do not match the VLAN database, the VTP mode and the VLAN configuration for the first 1005 VLANs use VLAN database information.
The following are the results of using the no vlan commands:
•When the no vlan vlan-id form is used, the VLAN is deleted. Deleting VLANs automatically resets to zero any other parent VLANs and translational bridging parameters that see the deleted VLAN.
•When the no vlan vlan-id bridge form is used, the VLAN source-routing bridge number returns to the default (0). The vlan vlan-id bridge command is used only for FDDI-NET and Token Ring-NET VLANs and is ignored in other VLAN types.
•When the no vlan vlan-id media form is used, the media type returns to the default (ethernet). Changing the VLAN media type (including the no form) resets the VLAN MTU to the default MTU for the type (unless the mtu keyword is also present in the command). It also resets the VLAN parent and translational bridging VLAN to the default (unless the parent, tb-vlan1, or tb-vlan2 are also present in the command).
•When the no vlan vlan-id mtu form is used, the VLAN MTU returns to the default for the applicable VLAN media type. You can also modify the MTU by using the media keyword.
•When the no vlan vlan-id name vlan-name form is used, the VLAN name returns to the default name (VLANxxxx, where xxxx represent four numeric digits [including leading zeros] equal to the VLAN ID number).
•When the no vlan vlan-id parent form is used, the parent VLAN returns to the default (0). The parent VLAN resets to the default if the parent VLAN is deleted or if the media keyword changes the VLAN type or the VLAN type of the parent VLAN.
•When the no vlan vlan-id ring form is used, the VLAN logical ring number returns to the default (0).
•When the no vlan vlan-id said form is used, the VLAN SAID returns to the default (100,000 plus the VLAN ID).
•When the no vlan vlan-id state form is used, the VLAN state returns to the default (active).
•When the no vlan vlan-id stp type form is used, the VLAN spanning-tree type returns to the default (ieee).
•When the no vlan vlan-id tb-vlan1 or no-id tb-vlan2 form is used, the VLAN translational bridge VLAN (or VLANs, if applicable) returns to the default (0). Translational bridge VLANs must be a different VLAN type than the affected VLAN, and if two are specified, the two must be different VLAN types from each other. A translational bridge VLAN resets to the default if the translational bridge VLAN is deleted, if the media keyword changes the VLAN type, or if the media keyword changes the VLAN type of the corresponding translation bridge VLAN.
Examples
This example shows how to add an Ethernet VLAN with default media characteristics. The default includes a vlan-name of VLANxxx, where xxxx represents four numeric digits (including leading zeros) equal to the VLAN ID number. The default media option is ethernet; the state option is active. The default said-value variable is 100000 plus the VLAN ID; the mtu-size variable is 1500; the stp-type option is ieee. When you enter the exit or apply vlan configuration command, the VLAN is added if it did not already exist; otherwise, this command does nothing.
Switch(vlan)# vlan 2
VLAN 2 added:
Name: VLAN0002
Switch(vlan)# exit
APPLY completed.
Exiting....
This example shows how to modify an existing VLAN by changing its name and MTU size:
Switch(vlan)# no vlan name engineering mtu 1200
You can verify your settings by entering the show vlan privileged EXEC command.
Related Commands
vlan database
Use the vlan database privileged EXEC command to enter VLAN configuration mode. From this mode, you can add, delete, and modify VLAN configurations for normal-range VLANs and globally propagate these changes by using the VLAN Trunking Protocol (VTP). Configuration information is saved in the VLAN database.
vlan database
Note VLAN configuration mode is only valid for VLAN IDs 1 to 1005.
Syntax Description
This command has no arguments or keywords.
Defaults
No default is defined.
Command Modes
Privileged EXEC
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
You can use the VLAN database configuration commands to configure VLANs 1 to 1005. To configure extended-range VLANs (VLAN IDs 1006 to 4094), use the vlan (global configuration) command to enter config-vlan mode. You can also configure VLAN IDs 1 to 1005 by using the vlan global configuration command.
To return to the privileged EXEC mode from the VLAN configuration mode, enter the exit command.
Note This command mode is different from other modes because it is session-oriented. When you add, delete, or modify VLAN parameters, the changes are not applied until you exit the session by entering the apply or exit command. When the changes are applied, the VTP configuration version is incremented. You can also not apply the changes to the VTP database by entering abort.
When you are in VLAN configuration mode, you can access the VLAN database and make changes by using these commands:
•vlan: accesses subcommands to add, delete, or modify values associated with a single VLAN. For more information, see the vlan (VLAN configuration) command.
•vtp: accesses subcommands to perform VTP administrative functions. For more information, see the vtp (VLAN configuration) command.
When you have modified VLAN or VTP parameters, you can use these editing buffer manipulation commands:
•abort: exits the mode without applying the changes. The VLAN configuration that was running before you entered VLAN configuration mode continues to be used.
•apply: applies current changes to the VLAN database, increments the database configuration revision number, propagates it throughout the administrative domain, and remains in VLAN configuration mode.
Note You cannot use this command when the switch is in VTP client mode.
•exit: applies all configuration changes to the VLAN database, increments the database configuration number, propagates it throughout the administrative domain, and returns to privileged EXEC mode.
•no: negates a command or set its defaults; valid values are vlan and vtp.
•reset: abandons proposed changes to the VLAN database, resets the proposed database to the implemented VLAN database on the switch, and remains in VLAN configuration mode.
•show: displays VLAN database information.
•show changes [vlan-id]: displays the differences between the VLAN database on the switch and the proposed VLAN database for all normal-range VLAN IDs (1 to 1005) or the specified VLAN ID (1 to 1005).
•show current [vlan-id]: displays the VLAN database on the switch or on a selected VLAN (1 to 1005).
•show proposed [vlan-id]: displays the proposed VLAN database or a selected VLAN (1 to 1005) from the proposed database. The proposed VLAN database is not the running configuration until you use the exit or apply VLAN configuration command.
You can verify that VLAN database changes have been made or aborted by using the show vlan privileged EXEC command. This output is different from the show VLAN database configuration command output.
Examples
This example shows how to enter the VLAN configuration mode from the privileged EXEC mode and to display VLAN database information:
Switch# vlan database
Switch(vlan)# show
VLAN ISL Id: 1
Name: default
Media Type: Ethernet
VLAN 802.10 Id: 100001
State: Operational
MTU: 1500
Translational Bridged VLAN: 1002
Translational Bridged VLAN: 1003
VLAN ISL Id: 2
Name: VLAN0002
Media Type: Ethernet
VLAN 802.10 Id: 100002
State: Operational
MTU: 1500
VLAN ISL Id: 1002
Name: fddi-default
Media Type: FDDI
VLAN 802.10 Id: 101002
State: Operational
MTU: 1500
Bridge Type: SRB
Ring Number: 0
Translational Bridged VLAN: 1
Translational Bridged VLAN: 1003
<output truncated>
This is an example of output from the show changes command:
Switch(vlan)# show changes
DELETED:
VLAN ISL Id: 4
Name: VLAN0004
Media Type: Ethernet
VLAN 802.10 Id: 100004
State: Operational
MTU: 1500
MODIFIED:
VLAN ISL Id: 7
Current State: Operational
Modified State: Suspended
This example shows how to display the differences between VLAN 7 in the current database and the proposed database.
Switch(vlan)# show changes 7
MODIFIED:
VLAN ISL Id: 7
Current State: Operational
Modified State: Suspended
This is an example of output from the show current 20 command. It displays only VLAN 20 of the current database.
Switch(vlan)# show current 20
VLAN ISL Id: 20
Name: VLAN0020
Media Type: Ethernet
VLAN 802.10 Id: 100020
State: Operational
MTU: 1500
Related Commands
vmps reconfirm (privileged EXEC)
Use the vmps reconfirm privileged EXEC command to immediately send VLAN Query Protocol (VQP) queries to reconfirm all dynamic VLAN assignments with the VLAN Membership Policy Server (VMPS).
vmps reconfirm
Syntax Description
This command has no arguments or keywords.
Defaults
No default is defined.
Command Modes
Privileged EXEC
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Examples
This example shows how to immediately send VQP queries to the VMPS:
Switch# vmps reconfirm
You can verify your setting by entering the show vmps privileged EXEC command and examining the VMPS Action row of the Reconfirmation Status section. The show vmps command shows the result of the last time the assignments were reconfirmed either because the reconfirmation timer expired or because the vmps reconfirm command was entered.
Related Commands
|
|
---|---|
Displays VQP and VMPS information. |
|
Changes the reconfirmation interval for the VQP client. |
vmps reconfirm (global configuration)
Use the vmps reconfirm global configuration command to change the reconfirmation interval for the VLAN Query Protocol (VQP) client. Use the no form of this command to return to the default setting.
vmps reconfirm interval
no vmps reconfirm
Syntax Description
interval |
Reconfirmation interval for VQP client queries to the VLAN Membership Policy Server (VMPS) to reconfirm dynamic VLAN assignments. The range is 1 to 120 minutes. |
Defaults
The default reconfirmation interval is 60 minutes.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Examples
This example shows how to set the VQP client to reconfirm dynamic VLAN entries every 20 minutes:
Switch(config)# vmps reconfirm 20
You can verify your setting by entering the show vmps privileged EXEC command and examining information in the Reconfirm Interval row.
Related Commands
|
|
---|---|
Displays VQP and VMPS information. |
|
Sends VQP queries to reconfirm all dynamic VLAN assignments with the VMPS. |
vmps retry
Use the vmps retry global configuration command to configure the per-server retry count for the VLAN Query Protocol (VQP) client. Use the no form of this command to return to the default setting.
vmps retry count
no vmps retry
Syntax Description
count |
Number of attempts to contact the VLAN Membership Policy Server (VMPS) by the client before querying the next server in the list. The range is 1 to 10. |
Defaults
The default retry count is 3.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Examples
This example shows how to set the retry count to 7:
Switch(config)# vmps retry 7
You can verify your setting by entering the show vmps privileged EXEC command and examining information in the Server Retry Count row.
Related Commands
|
|
---|---|
Displays VQP and VMPS information. |
vmps server
Use the vmps server global configuration command to configure the primary VLAN Membership Policy Server (VMPS) and up to three secondary servers. Use the no form of this command to remove a VMPS server.
vmps server ipaddress [primary]
no vmps server [ipaddress]
Syntax Description
Defaults
No primary or secondary VMPS servers are defined.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
The first server entered is automatically selected as the primary server whether or not primary is entered. The first server address can be overridden by using primary in a subsequent command.
If a member switch in a cluster configuration does not have an IP address, the cluster does not use the VMPS server configured for that member switch. Instead, the cluster uses the VMPS server on the command switch, and the command switch proxies the VMPS requests. The VMPS server treats the cluster as a single switch and uses the IP address of the command switch to respond to requests.
When using the no form without specifying the ipaddress, all configured servers are deleted. If you delete all servers when dynamic-access ports are present, the switch cannot forward packets from new sources on these ports because it cannot query the VMPS.
Examples
This example shows how to configure the server with IP address 191.10.49.20 as the primary VMPS server. The servers with IP addresses 191.10.49.21 and 191.10.49.22 are configured as secondary servers:
Switch(config)# vmps server 191.10.49.20 primary
Switch(config)# vmps server 191.10.49.21
Switch(config)# vmps server 191.10.49.22
This example shows how to delete the server with IP address 191.10.49.21:
Switch(config)# no vmps server 191.10.49.21
You can verify your setting by entering the show vmps privileged EXEC command and examining information in the VMPS Domain Server row.
Related Commands
|
|
---|---|
Displays VQP and VMPS information. |
vtp (global configuration)
Use the vtp global configuration command to set or modify the VLAN Trunking Protocol (VTP) configuration characteristics. Use the no form of this command to remove the settings or to return to the default settings.
vtp {domain domain-name | file filename | interface name [only] | mode {client | server | transparent} | password password | pruning | version number}
no vtp {file | interface | mode | password | pruning | version}
Syntax Description
Defaults
The default filename is flash:vlan.dat.
The default mode is server mode.
No domain name or password is defined.
No password is configured.
Pruning is disabled.
The default version is Version 1.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
When you save VTP mode, domain name, and VLAN configurations in the switch startup configuration file and reboot the switch, the VTP and VLAN configurations are selected by these conditions:
•If both the VLAN database and the configuration file show the VTP mode as transparent and the VTP domain names match, the VLAN database is ignored. The VTP and VLAN configurations in the startup configuration file are used. The VLAN database revision number remains unchanged in the VLAN database.
•If the startup VTP mode is server mode, or the startup VTP mode or domain names do not match the VLAN database, VTP mode and VLAN configuration for the first 1005 VLANs are selected by VLAN database information, and VLANs greater than 1005 are configured from the switch configuration file.
The vtp file filename cannot be used to load a new database; it renames only the file in which the existing database is stored.
Follow these guidelines when configuring a VTP domain name:
•The switch is in the no-management-domain state until you configure a domain name. While in the no-management-domain state, the switch does not send any VTP advertisements even if changes occur to the local VLAN configuration. The switch leaves the no-management-domain state after it receives the first VTP summary packet on any port that is trunking or after you configure a domain name by using the vtp domain command. If the switch receives its domain from a summary packet, it resets its configuration revision number to 0. After the switch leaves the no-management-domain state, it can no be configured to re-enter it until you clear the NVRAM and reload the software.
•Domain names are case-sensitive.
•After you configure a domain name, it cannot be removed. You can only reassign it to a different domain.
Follow these guidelines when setting VTP mode:
•The no vtp mode command returns the switch to VTP server mode.
•The vtp mode server command is the same as no vtp mode except that it does not return an error if the switch is not in client or transparent mode.
•If the receiving switch is in client mode, the client switch changes its configuration to duplicate the configuration of the server. If you have switches in client mode, be sure to make all VTP or VLAN configuration changes on a switch in server mode. If the receiving switch is in server mode or transparent mode, the switch configuration is not changed.
•Switches in transparent mode do not participate in VTP. If you make VTP or VLAN configuration changes on a switch in transparent mode, the changes are not propagated to other switches in the network.
•If you change the VTP or VLAN configuration on a switch that is in server mode, that change is propagated to all the switches in the same VTP domain.
•The vtp mode transparent command disables VTP from the domain but does not remove the domain from the switch.
•The VTP mode must be transparent for you to add extended-range VLANs or for VTP and VLAN information to be saved in the running configuration file.
•If extended-range VLANs are configured on the switch and you attempt to set the VTP mode to server or client, you receive an error message, and the configuration is not allowed.
•VTP can be set to either server or client mode only when dynamic VLAN creation is disabled.
Follow these guidelines when setting a VTP password:
•Passwords are case sensitive. Passwords should match on all switches in the same domain.
•When you use the no vtp password form of the command, the switch returns to the no-password state.
Follow these guidelines when setting VTP pruning:
•VTP pruning removes information about each pruning-eligible VLAN from VTP updates if there are no stations belonging to that VLAN.
•If you enable pruning on the VTP server, it is enabled for the entire management domain for VLAN IDs 1 to 1005.
•Only VLANs in the pruning-eligible list can be pruned.
•Pruning is supported with VTP Version 1 and Version 2.
Follow these guidelines when setting the VTP version:
•Toggling the Version 2 (v2) mode state modifies parameters of certain default VLANs.
•Each VTP switch automatically detects the capabilities of all the other VTP devices. To use Version 2, all VTP switches in the network must support Version 2; otherwise, you must configure them to operate in VTP Version 1 mode.
•If all switches in a domain are VTP Version 2-capable, you need only to configure Version 2 on one switch; the version number is then propagated to the other Version-2 capable switches in the VTP domain.
•If you are using VTP in a Token Ring environment, VTP Version 2 must be enabled.
•If you are configuring a Token Ring bridge relay function (TrBRF) or Token Ring concentrator relay function (TrCRF) VLAN media type, you must use Version 2.
•If you are configuring a Token Ring or Token Ring-NET VLAN media type, you must use Version 1.
You cannot save password, pruning, and version configurations in the switch configuration file.
Examples
This example shows how to rename the filename for VTP configuration storage to vtpfilename:
Switch(config)# vtp file vtpfilename
This example shows how to clear the device storage filename:
Switch(config)#
no vtp file vtpconfig
Clearing device storage filename.
This example shows how to specify the name of the interface providing the VTP updater ID for this device:
Switch(config)#
vtp interface gigabitethernet
This example shows how to set the administrative domain for the switch:
Switch(config
)# vtp domain OurDomainName
This example shows how to place the switch in VTP transparent mode:
Switch(config
)# vtp mode transparent
This example shows how to configure the VTP domain password:
Switch(config
)# vtp password ThisIsOurDomain'sPassword
This example shows how to enable pruning in the VLAN database:
Switch(config
)# vtp pruning
Pruning switched ON
This example shows how to enable Version 2 mode in the VLAN database:
Switch(config
)# vtp version 2
You can verify your settings by entering the show vtp status privileged EXEC command.
Related Commands
|
|
---|---|
show vtp status |
Displays the VTP statistics for the switch and general information about the VTP management domain status. |
Configures VTP domain-name, password, pruning, version, and mode. |
vtp (VLAN configuration)
Use the vtp VLAN configuration command to configure VLAN Trunking Protocol (VTP) characteristics. You access VLAN configuration mode by entering the vlan database privileged EXEC command. Use the no form of this command to return to the default settings, disable the characteristic, or remove the password.
vtp {domain domain-name | password password | pruning | v2-mode | {server | client | transparent}}
no vtp {client | password | pruning | transparent | v2-mode}
Syntax Description
Defaults
The default mode is server mode.
No domain name is defined.
No password is configured.
Pruning is disabled.
VTP Version 2 (v2 mode) is disabled.
Command Modes
VLAN configuration
Command History
|
|
---|---|
12.2(37)EY |
This command was introduced. |
Usage Guidelines
If the VTP mode is transparent, the mode and domain name are saved in the switch running configuration file, and you can save the configuration in the switch startup configuration file by using the copy running-config startup-config privileged EXEC command.
Follow these guidelines when setting the VTP mode:
•The no vtp client and no vtp transparent forms of the command return the switch to VTP server mode.
•The vtp server command is the same as no vtp client or no vtp transparent except that it does not return an error if the switch is not in client or transparent mode.
•If the receiving switch is in client mode, the client switch changes its configuration to duplicate the configuration of the server. If you have switches in client mode, make sure to make all VTP or VLAN configuration changes on a switch in server mode. If the receiving switch is in server mode or transparent mode, the switch configuration is not changed.
•Switches in transparent mode do not participate in VTP. If you make VTP or VLAN configuration changes on a switch in transparent mode, the changes are not propagated to other switches in the network.
•If you make a change to the VTP or VLAN configuration on a switch in server mode, that change is propagated to all the switches in the same VTP domain.
•The vtp transparent command disables VTP from the domain but does not remove the domain from the switch.
•The VTP mode must be transparent for you to add extended-range VLANs or for the VTP and the VLAN configurations to be saved in the running configuration file.
•If extended-range VLANs are configured on the switch and you attempt to set the VTP mode to server or client, you receive an error message and the configuration is not allowed.
•VTP can be set to either server or client mode only when dynamic VLAN creation is disabled.
Note VTP configuration in VLAN configuration mode is saved in the VLAN database when applied.
Follow these guidelines when configuring a VTP domain name:
•The switch is in the no-management-domain state until you configure a domain name. While in the no-management-domain state, the switch does not send any VTP advertisements even if changes occur to the local VLAN configuration. The switch leaves the no-management-domain state after receiving the first VTP summary packet on any port that is currently trunking or after configuring a domain name with the vtp domain command. If the switch receives its domain from a summary packet, it resets its configuration revision number to zero. After the switch leaves the no-management-domain state, it can never be configured to reenter it until you clear the NVRAM and reload the software.
•Domain names are case sensitive.
•After you configure a domain name, it cannot be removed. You can reassign it only to a different domain.
Follow these guidelines when configuring a VTP password:
•Passwords are case sensitive. Passwords should match on all switches in the same domain.
•When the no vtp password form of the command is used, the switch returns to the no-password state.
Follow these guidelines when enabling VTP pruning:
•If you enable pruning on the VTP server, it is enabled for the entire management domain.
•Only VLANs included in the pruning-eligible list can be pruned.
•Pruning is supported with VTP Version 1 and Version 2.
Follow these guidelines when enabling VTP Version 2 (v2-mode):
•Toggling the version (v2-mode) state modifies certain parameters of certain default VLANs.
•Each VTP switch automatically detects the capabilities of all the other VTP devices. To use VTP Version 2, all VTP switches in the network must support Version 2; otherwise, you must configure them to operate in VTP Version 1 (no vtp v2-mode).
•If all switches in a domain are VTP Version 2-capable, you need only to enable VTP Version 2 on one switch; the version number is then propagated to the other Version-2 capable switches in the VTP domain.
•If you are using VTP in a Token Ring environment or configuring a Token Ring bridge relay function (TrBRF) or Token Ring concentrator relay function (TrCRF) VLAN media type, VTP Version 2 (v2-mode) must be enabled.
•If you are configuring a Token Ring or Token Ring-NET VLAN media type, you must use VTP Version 1.
Examples
This example shows how to place the switch in VTP transparent mode:
Switch(vlan)# vtp transparent
Setting device to VTP TRANSPARENT mode.
This example shows how to set the administrative domain for the switch:
Switch(vlan)# vtp domain OurDomainName
Changing VTP domain name from cisco to OurDomainName
This example shows how to configure the VTP domain password:
Switch(vlan)# vtp password private
Setting device VLAN database password to private.
This example shows how to enable pruning in the proposed new VLAN database:
Switch(vlan)# vtp pruning
Pruning switched ON
This example shows how to enable v2 mode in the proposed new VLAN database:
Switch(vlan)# vtp v2-mode
V2 mode enabled.
You can verify your settings by entering the show vtp status privileged EXEC command.
Related Commands
|
|
---|---|
show vtp status |
Displays the VTP statistics for the switch and general information about the VTP management domain status. |
switchport trunk pruning |
Configures the VLAN pruning-eligible list for ports in trunking mode. |
Configures the VTP filename, interface, domain name, and mode. |