System Management Commands

To use these commands in System Admin VM, you must be in a user group associated with appropriate command rules and data rules. If the user group assignment is preventing you from using a command, contact your AAA administrator for assistance.

activate advanced

To enable access to advanced system admin commands and configurations used for debugging purpose, use the activate advanced command in System Admin EXEC mode.

activate advanced

Syntax Description

This command has no keywords or arguments.

Command Default

None

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

This command should not be used unless specifically requested by Cisco TAC or another Cisco support representative.

Examples

This example shows sample output from the activate advanced command:

sysadmin-vm:0_RP0# activate advanced 
Advanced commands must be used carefully. Continue? [yes,NO] yes
Tue Aug  29 20:05:16.635 UTC
sysadmin-vm:0_RP0#

attach location

To connect to a host from a remote location, use the attach location command in the System Admin EXEC and XR EXEC modes.

attach location node-id

Syntax Description

node-id

Specifies the target location. The node-id argument is expressed in the rack/ slot notation.

Command Default

None

Command Modes

System Admin EXEC

XR EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Users can attach the host only to RP and LC nodes.

When this command is executed, the user gets into the (low-level) shell prompt of the remote node specified.

Examples

This example shows how to attach the host to the node:

sysadmin-vm:0_RP0#attach location 0/RP0

exec chvrf 2 bash
^@[sysadmin-vm:0_RP0:~]$ exec chvrf 2 bash
[sysadmin-vm:0_RP0:~]$

environment

To configure environment parameters for the chassis, use the environment variable in the System Admin Config mode.

environment {air-filter replaced date | router altitude meters}

Syntax Description

air-filter

Configures chassis air filter status.

replaced date

Specifies air filter replacement date. Enter the date using the yyyy-mm-dd format.

router

Configures chassis environment properties.

altitude meters

Specifies the chassis altitude above sea level in meters. Valid values are from 1 to 4000.

Command Default

Router altitude is disabled by default.

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Release 6.1.2

The high-altitude keyword has been replaced with the altitude meters keyword.

Usage Guidelines

Use the environment router altitude meters command to increase the fan speed based on the specified altitude. When the altitude is above 6000 ft (1829 m), the fan speed increases.

Use the environment air-filter replaced date command to specify the date you replaced the air filter. After 6 months, you will be prompted once to replace the air filter if you receive a high-temperature alarm:

%PKT_INFRA-FM-6-FAULT_INFO : Fan filter replacement warning :DECLARE :0: Fan Tray filter replacement interval has been exceeded. Last filter reset time 2016-07-01

Note


The filter replacement warning is only displayed once after the first high-temperature warning.

Examples

This example shows how to configure the router altitude:

sysadmin-vm:0_RP0#config
sysadmin-vm:0_RP0(config)#environment router altitude 1430
sysadmin-vm:0_RP0(config)#commit
Sun Jul 30 17:49:25.310 UTC
Commit complete.
This example shows how to configure the router air-filter replacement date:

sysadmin-vm:0_RP0(config)#environment air-filter replaced 2016-07-30
sysadmin-vm:0_RP0(config)#commit
Sun Jul 30 17:49:53.312 UTC
Commit complete.

fpd auto-upgrade

To enable the automatic upgrade of FPD images during a software upgrade, use the fpd auto-upgrade command in System Admin Config mode. To disable automatic FPD upgrades, use the no form of this command.

fpd auto-upgrade [disable | enable]

no fpd auto-upgrade

Syntax Description

disable

Disables automatic upgrade of FPD images.

enable

Enables automatic upgrade of FPD images.

Command Default

FPD automatic upgrade is disabled by default.

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Users are recommended to enable automatic upgrade of FPD on the system.

Examples

This example shows how to enable fpd auto-upgrade:

sysadmin-vm:0_RP0#config
sysadmin-vm:0_RP0(config)#fpd auto-upgrade enable
sysadmin-vm:0_RP0(config)# commit
Sat Aug  31 00:39:44.503 UTC
Commit complete.
sysadmin-vm:0_RP0(config)# end

interface

To configure the management interface, use the interface command in the System Admin Config mode. To disable the management interface, use the no form of this command.

interface MgmtEth location

Syntax Description

location

Specifies the location of the management Ethernet interface.

Command Default

None

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

This command is applicable only for RP nodes.

Examples

This example shows how to configure the management ethernet interface:

sysadmin-vm:0_RP0# config
sysadmin-vm:0_RP0(config)# interface MgmtEth 0/RP0/0/0

sysadmin-vm:0_RP0(config-MgmtEth-0/RP0/0/0)# ipv4 address 12.28.59.104/16

sysadmin-vm:0_RP0(config-MgmtEth-0/RP0/0/0)# default-gw 12.28.0.1
sysadmin-vm:0_RP0(config-MgmtEth-0/RP0/0/0)#commit
Wed Aug  28 17:56:25.562 UTC
Commit complete.
sysadmin-vm:0_RP0(config-MgmtEth-0/RP0/0/0)#end
Wed Aug  28 17:56:28.307 UTC
sysadmin-vm:0_RP0# show running-config interface MgmtEth
Wed Aug  28 17:56:32.444 UTC
interface MgmtEth 0/RP0/0/0
 ipv4 address 12.28.59.104/16
 default-gw 12.28.0.1
!
sysadmin-vm:0_RP0#

logging console

To modify message logging facilities for a group, use the logging console command in the System Admin Config mode. To disable message logging facilities, use the no form of this command.

logging console {alert | critical | debug | disable | emergency | error | informational | notice | warning}

no logging console

Syntax Description

alert

Indicates immediate action is required

critical

Indicates critical conditions.

debug

Indicates debugging messages.

disable

Disables logging.

emergency

Indicates that the system is unusable.

error

Indicates error conditions.

informational

Indicates informational messages.

notice

Indicates normal but significant conditions.

warning

Indicated warning conditions.

Command Default

Logging is set to Warning.

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Use the logging console command to prevent debugging messages from flooding your screen.

The logging console is for the console terminal. Use the logging console disable command to disable console logging completely.

Use the no logging console command to return the configuration to the default setting.

Examples

This example shows how to disable logging:

sysadmin-vm:0_RP0#config
sysadmin-vm:0_RP0(config)# logging console disable

mgmt

To configure IP address of the management interface, use the mgmt command in the System Admin Config mode. To clear the IP address assigned to the management interface, use the no form of this command.

mgmt {ipv4 [A.B.C.D/subnet_bits | A.B.C.D subnet_ip] | ipv6 [IPv6address/prefix | Address Prefix_ipv6 address]}

Syntax Description

ipv4

Specifies an IPv4 address.

ipv6

Specifies an IPv6 address.

A.B.C.D/subnet_bits

Assigns an IPv4 address and subnet mask to the interface in the specified format.

A.B.C.D subnet_ip

Assigns an IPv4 address and subnet mask to the interface in the specified format.

IPv6address/prefix

Assigns an IPv6 address and prefix in the specified format.

Address Prefix_ipv6 address

Assigns an IPv6 address and prefix in the specified format.

Command Default

None

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

This command does not configure the physical management interface. It is similar to configuring ipv4 or ipv6 virtual address to the management interfaces.

Examples

This example shows how to configure the IP address of the management interface:
sysadmin-vm:0_RP0# config
sysadmin-vm:0_RP0(config)# mgmt ipv4 12.28.59.104/16
sysadmin-vm:0_RP0(config)# commit
Sat Aug  31 00:41:20.910 UTC
Commit complete.
sysadmin-vm:0_RP0(config)# end
Sat Aug  31 00:41:21.211 UTC
sysadmin-vm:0_RP0#

power-mgmt action

To control the power budget so as to not exceed the power capacity, use the power-mgmt action command in the System Admin Config mode. To disable the power budget control, use the no form of this command.

power-mgmt action disable location chassis-id

Syntax Description

disable

Disables the power budget control.

location chassis-id

Specifies the target location to disable the power budget control. Enter the chassis identifier.

Command Default

Power budget control is enabled by default.

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Power-management action is done at the chassis level.

Examples

This example shows you how to disable the chassis power management control:

sysadmin-vm:0_RP0# config
sysadmin-vm:0_RP0(config)# power-mgmt action disable location 10

power-mgmt redundancy

To disable power tray level redundancy and convert to power module redundancy, use the power-mgmt redundancy-num-pms command in the System Admin Config mode. To restore default power tray level redundancy, use the no form of this command.

power-mgmt redundancy-num-pms [ integer]

no power-mgmt redundancy-num-pms [ integer]

Syntax Description

integer Number of redundant power modules that the user wants to configure. The total number of functioning power modules in the system is at least integer number more than the number of power modules needed to support the power required for all the cards in the system. Range of integer is from 0 to 12. 0 means no power redundancy is required.

Command Default

Power tray level redundancy is the default option.

The router has two power shelves where each power shelf contains three power trays for LCC (line card chassis) and two power trays for FCC (fabric card chassis).

Power tray level redundancy indicates that both power shelves contain sufficient functioning power modules to support power required for all the cards in the system.

Command Modes

System Admin Config

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

If the system is planned to have power tray level (N+N) power redundancy, then the power redundancy mode need not be configured as that is the default mode.

If the system is planned to have power module redundancy (N+x), then this command can be used to set the number of power modules required for power redundancy.

Examples

This example shows how to disable power tray level redundancy and convert it to power module level redundancy:

sysadmin-vm:0_RP0#config
sysadmin-vm:0_RP0(config)#power-mgmt redundancy-num-pms 2
sysadmin-vm:0_RP0(config)#commit
Tue Sep  3  12:17:53.891 UTC
Commit complete.

users

To configure a user and associate the user with an authentication group, use the user command. To delete a user from the specified user group, use the no form of this command.

user user-name

no user user-name

Syntax Description

user-name

Name of the user to be added to the users list.

Command Default

None

Command History

Release

Modification

Release 5.2.3

This command was introduced.

Usage Guidelines

No specific guidelines impact the use of this command.

Task ID

Task ID

Operations

aaa

read, write

Examples

The following example shows how to add a user user1 to the list of users in user group grp1:


sysadmin-vm:0_RP0(config)#aaa authentication groups group grp1	
sysadmin-vm:0_RP0(config-group-grp1)# users user1
Wed Nov  19 15:50:11.706 UTC
sysadmin-vm:0_RP0(config-group-grp1)# commit

This example shows how to view that the user user1 is successfully added to user group grp1:


sysadmin-vm:0_RP0# show running-config aaa authentication groups group grp1	
Wed Nov  19 15:51:32.679 UTC
aaa authentication groups group grp1
 gid   100
 users "%%__system_user__%% user1"
!

This example shows how to delete the user user1 from user group grp1:


sysadmin-vm:0_RP0(config-group-grp1)# no users user1	
Wed Nov  19 15:53:28.961 UTC
sysadmin-vm:0_RP0(config-group-grp1)# commit

This example shows how to delete all the users from user group grp1:


sysadmin-vm:0_RP0(config-group-grp1)# no users	
Wed Nov  19 15:55:41.121 UTC
sysadmin-vm:0_RP0(config-group-grp1)# commit

show card-inventory

To display System Admin Manager card inventory information, use the show card-inventory command in the System Admin EXEC mode.

show card-inventory [location node-id]

Syntax Description

location node-id

Specifies the target location. The node-id argument is expressed in the rack/ slot notation.

Command Default

None

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

The location keyword can be used only with RP and LC nodes. However, the output displays information about all the cards (RP, LC, and FC)

Examples

This example shows sample output from the show card-inventory command:

sysadmin-vm:0_RP0# show card-inventory location 0/3

card-inventory location 0/3
 SAD160801NG
  card_type     RP
  card_state    OPERATIONAL
  card_sw_state OPERATIONAL
  card_slot     1
 SAD160801NP
  card_type     RP
  card_state    OPERATIONAL
  card_sw_state OPERATIONAL
  card_slot     0
 SAD161300T6
  card_type     LC
  card_state    OPERATIONAL
  card_sw_state OPERATIONAL
  card_slot     19
 SAD1618003Z
  card_type     FABRIC
  card_state    PRESENT
  card_sw_state UNKNOWN
  card_slot     8
 SAD162001MS
  card_type     LC
.
.
.

show environment

To display hardware information of the router, use the show environment command in System Admin EXEC mode.

show environment [all | current | fan | power | temperatures | trace | voltages ] [location node-id]

Syntax Description

all

(Optional) Displays information for all environmental monitor parameters.

current

(Optional) Displays current information.

fan

(Optional) Displays information about the fan.

power

(Optional) Displays power supply voltage.

temperatures

(Optional) Displays system temperature information.

trace

(Optional) Displays trace data for environment monitoring.

voltages

(Optional) Displays system voltage information.

location node-id

(Optional) Node whose information you want to display. The node-id argument is expressed in the rack/ slot notation.

Command Default

All environmental monitor parameters are displayed.

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

The show environment command displays information about the hardware that is installed in the system, including fans, LEDs, system power, voltages, current, and temperature information.

Examples

This example shows how to displays current information at the specified location:


sysadmin-vm:0_RP0#show environment current location 0/3
================================================================================
Location  Sensor                      Value
                                      (mA)
================================================================================
0/3
          VRM12 VCC In CS               468
          VRM12 VSA In CS               250
          VRM12 VCC Out CS             5500
          VRM12 VSA Out CS             3000
          Hot Swap(HS_0) CS            4500
          VP3P3 MB CS                  1590
          VP1P8 MB CS                   350
          VP1P0 MB CS                  1010
          VP0P9 MB CS                   400
          VP0P9_GN MB CS                 20
          VP1P5_DDR3 MB CS              160
          VP1P05 MB CS                  360
          CPU VCC CS                    710
          VP2P5 MB CS                  1110
          Slice 1 VP1P0_SRDS CS         680
          Slice 1 VP1P5 CS             2450
          Slice 1 PITA VP1P0 CS         725
          Slice 1 VP0P9 AVS A CS       2102
This example shows how to display fan information at the specified location:
sysadmin-vm:0_RP0# show environment fan location 0/FT0

================================================================================
                              Fan speed (rpm)
Location     FRU Type         FAN_0   FAN_1   FAN_2   FAN_3   FAN_4   FAN_5
================================================================================
0/FT0        P-L-FANTRAY       2680    2720    2680    2720    2720    2720   
sysadmin-vm:0_RP0# 
--

sysadmin-vm:0_RP0# show environment power location 0/FC0
Fri Sep  20 02:47:11.268 UTC

================================================================================
   Location     Card Type            Power       Status
                                     Allocated
                                     Watts
================================================================================
   0/FC0        NC6-FC                 150       ON 
This example shows how to display temperature information at the specified location:
sysadmin-vm:0_RP0# show environment temperatures location 0/FC0

================================================================================
Location  Sensor                      Value   Crit Major Minor Minor Major  Crit
                                    (deg C)   (Lo) (Lo)  (Lo)  (Hi)  (Hi)   (Hi)
================================================================================
0/FC0        
          Inlet                          27    -10    -5     0    50    60    75
          HotSpot                        32    -10    -5     0    95   100   105
          Outlet                         29    -10    -5     0    95   100   105
          PCIe Die                       47    -10    -5     0   105   115   120
This example shows how to display voltages information at the specified location:
sysadmin-vm:0_RP0# show environment voltages location 0/FC0

================================================================================
Location  Sensor                      Value   Crit Minor Minor  Crit
                                      (mV)    (Lo) (Lo)  (Hi)   (Hi)
================================================================================
0/FC0        
          Hot Swap(HS_0) VS           55309  48600 49950 58050 59400
          Standby rails(IMON_0)        9975   8000  8500 11500 12210
          Common rails(IMON_1)         9950   8000  8500 11500 12210
          PS_0 Stdby VP1P2             1200   1080  1110  1290  1320
          PS_0-Stdby VP3P3             3298   2970  3050  3550  3630
          PS_0-Ref VP2P5               2499   2250  2310  2690  2750
          PS_0-IBV DIV4                2492   2000  2215  2875  3053
          PS_0-PB VP7P0 DIV2           3499   3150  3240  3760  3850
          PS_0-PCIE VP1P8              1800   1620  1665  1935  1980
          PS_0-PCIE VP0P9               900    810   830   970   990
          PS_0-VP12P0                  9937   8000  8500 11500 12210
          PS_2 FE0 VDDC                1000    900   925  1075  1100
          PS_2 FE0 TRVDD                999    900   925  1075  1100
          PS_2 FE0 FTRVDD               999    900   925  1075  1100
          PS_2 FE0 VP3P3               3299   2970  3050  3550  3630
          PS_2 FE1 VDDC                1000    900   925  1075  1100
          PS_2 FE1 TRVDD                999    900   925  1075  1100
          PS_2 FE1 FTRVDD               999    900   925  1075  1100
          PS_2 FE1 VP3P3               3299   2970  3050  3550  3630
          PS_2-VP12P0                 10031   8000  8500 11500 12210
          Falafel 0 core               9925   8000  8500 11500 12210
          Falafel 0 SerDes             9950   8000  8500 11500 12210
          Falafel 0 3.3V               9900   8000  8500 11500 12210
          Falafel 1 core               9925   8000  8500 11500 12210
          Falafel 1 SerDes             9950   8000  8500 11500 12210
          Falafel 1 3.3V               9925   8000  8500 11500 12210

show fm

To display fault management information, use the show fm command in the System Admin EXEC and XR EXEC modes.

show fm location node-id

Syntax Description

location node-id

Specifies the node ID to which fault management is to be scoped. The node-id argument is expressed in the rack/ slot notation.

Command Default

None

Command Modes

System Admin EXEC

XR EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Examples

This example shows the sample output from the show fm command:

sysadmin-vm:0_RP0# show fm location 0/3
Fri Aug  2  06:22:21.925 UTC

-----------------------------------------
            Fault List Brief
------------------------------------------
           fault  fault
subsystem  type   tag    name
-------------------------------------------------
4          10     100    Shutdown card
4          14     1      Temperature alarm
4          14     2      High Voltage alarm
4          14     3      Low Voltage alarm
4          14     4      Sensor fault alarm
4          14     5      out of tolerance fault
4          14     6      I2C Access error


-----------------------------------------
            Fault Detailed Info
------------------------------------------
  detail fm_subsystem_id 4
  detail fm_fault_type 10
  detail fm_fault_tag 100
  detail name        "Shutdown card"
.
.
.

show fpd package

To display field-programmable device (FPD) package information, use the show fpd package command in System Admin EXEC mode.

show fpd package

Syntax Description

This command has no keywords or arguments.

Command Default

None

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

If there are multiple FPD images for your card, use the show fpd package command to determine which FPD image to use if you only want to upgrade a specific FPD type.

Examples

This example shows sample output from the show fpd package command:

sysadmin-vm:0_RP0# show fpd package 

=============================== ================================================
                                        Field Programmable Device Package
                                ================================================
                                               Req     SW      Min Req   Min Req
Card Type            FPD Description           Reload  Ver     SW Ver  Board Ver
=================== ========================== ====== ======= ======== =========
NC6-4-10X100G-M-K    BAO-MB FPGA                NO      1.00      1.00      0.0 
                     BAO-DB FPGA                NO      1.00      1.00      0.0 
                     Slice-0 GN2411             YES     2.07      2.07      0.0 
                     Slice-1 GN2411             YES     2.07      2.07      0.0 
                     Slice-2 GN2411             YES     2.07      2.07      0.0 
                     Slice-3 GN2411             YES     2.07      2.07      0.0 
                     Slice-4 GN2411             YES     2.07      2.07      0.0 
                     S2 GN2411                  YES     2.07      2.07      0.0 
                     S3 GN2411                  YES     2.07      2.07      0.0 
                     S4 GN2411                  YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-FC               CCC FPGA                   YES     1.13      1.13      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-10X100G-L-K      BAO-MB FPGA                NO      1.00      1.00      0.0 
                     BAO-DB FPGA                NO      1.00      1.00      0.0 
                     S2 GN2411                  YES     3.01      3.01      2.0 
                     S3 GN2411                  YES     3.01      3.01      2.0 
                     S4 GN2411                  YES     3.01      3.01      2.0 
                     S2 GN2411                  YES     2.07      2.07      0.0 
                     S3 GN2411                  YES     2.07      2.07      0.0 
                     S4 GN2411                  YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-6-10X100G-L-K    BAO-MB FPGA                NO      1.00      1.00      0.0 
                     BAO-DB FPGA                NO      1.00      1.00      0.0 
                     Slice-0 GN2411             YES     2.07      2.07      0.0 
                     Slice-1 GN2411             YES     2.07      2.07      0.0 
                     Slice-2 GN2411             YES     2.07      2.07      0.0 
                     Slice-3 GN2411             YES     2.07      2.07      0.0 
                     Slice-4 GN2411             YES     2.07      2.07      0.0 
                     S2 GN2411                  YES     2.07      2.07      0.0 
                     S3 GN2411                  YES     2.07      2.07      0.0 
                     S4 GN2411                  YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
PROTO-CXP-2XPITA     BAO-MB FPGA                NO      1.00      1.00      0.0 
                     Slice-0 GN2411             YES     3.01      3.01      2.0 
                     Slice-1 GN2411             YES     3.01      3.01      2.0 
                     Slice-0 GN2411             YES     2.07      2.07      0.0 
                     Slice-1 GN2411             YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-FANTRAY          Fantray FPGA               NO      2.01      2.01      0.0 
--------------------------------------------------------------------------------
NC6-10X100G-M-P      BAO-MB FPGA                NO      1.00      1.00      0.0 
                     BAO-DB FPGA                NO      1.00      1.00      0.0 
                     Slice-0 GN2411             YES     3.01      3.01      2.0 
                     Slice-1 GN2411             YES     3.01      3.01      2.0 
                     Slice-0 GN2411             YES     2.07      2.07      0.0 
                     Slice-1 GN2411             YES     2.07      2.07      0.0 
                     Slice-2 GN2411             YES     3.01      3.01      2.0 
                     Slice-3 GN2411             YES     3.01      3.01      2.0 
                     Slice-4 GN2411             YES     3.01      3.01      2.0 
                     Slice-2 GN2411             YES     2.07      2.07      0.0 
                     Slice-3 GN2411             YES     2.07      2.07      0.0 
                     Slice-4 GN2411             YES     2.07      2.07      0.0 
                     S2 GN2411                  YES     3.01      3.01      2.0 
                     S3 GN2411                  YES     3.01      3.01      2.0 
                     S4 GN2411                  YES     3.01      3.01      2.0 
                     S2 GN2411                  YES     2.07      2.07      0.0 
                     S3 GN2411                  YES     2.07      2.07      0.0 
                     S4 GN2411                  YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-10X100G-M-K      BAO-MB FPGA                NO      1.00      1.00      0.0 
                     BAO-DB FPGA                NO      1.00      1.00      0.0 
                     S2 GN2411                  YES     3.01      3.01      2.0 
                     S3 GN2411                  YES     3.01      3.01      2.0 
                     S4 GN2411                  YES     3.01      3.01      2.0 
                     S2 GN2411                  YES     2.07      2.07      0.0 
                     S3 GN2411                  YES     2.07      2.07      0.0 
                     S4 GN2411                  YES     2.07      2.07      0.0 
                     CPAK bay 0 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 1 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 2 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 3 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 4 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 5 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 6 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 7 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 8 FPD             YES     1.13      1.13      0.0 
                     CPAK bay 9 FPD             YES     1.13      1.13      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-10X100G-L-P      BAO-MB FPGA                NO      1.00      1.00      0.0 
                     BAO-DB FPGA                NO      1.00      1.00      0.0 
                     Slice-0 GN2411             YES     3.01      3.01      2.0 
                     Slice-1 GN2411             YES     3.01      3.01      2.0 
                     Slice-0 GN2411             YES     2.07      2.07      0.0 
                     Slice-1 GN2411             YES     2.07      2.07      0.0 
                     Slice-2 GN2411             YES     3.01      3.01      2.0 
                     Slice-3 GN2411             YES     3.01      3.01      2.0 
                     Slice-4 GN2411             YES     3.01      3.01      2.0 
                     Slice-2 GN2411             YES     2.07      2.07      0.0 
                     Slice-3 GN2411             YES     2.07      2.07      0.0 
                     Slice-4 GN2411             YES     2.07      2.07      0.0 
                     S2 GN2411                  YES     3.01      3.01      2.0 
                     S3 GN2411                  YES     3.01      3.01      2.0 
                     S4 GN2411                  YES     3.01      3.01      2.0 
                     S2 GN2411                  YES     2.07      2.07      0.0 
                     S3 GN2411                  YES     2.07      2.07      0.0 
                     S4 GN2411                  YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
NC6-RP               CCC FPGA                   YES     1.00      1.00      0.0 
                     CCC Power-On               YES     1.31      1.31      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.2 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     CPU Complex FPD            YES     3.06      3.06      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------
PWR-2KW-DC-V2        DT-PriMCU                  NO      6.02      6.02      0.1 
                     DT-Sec54vMCU               NO      6.02      6.02      0.1 
                     DT-Sec5vMCU                NO      6.02      6.02      0.1 
                     EM-PriMCU                  NO      3.06      3.06      0.2 
                     EM-Sec54vMCU               NO      3.09      3.09      0.2 
                     EM-Sec5vMCU                NO      3.07      3.07      0.2 
--------------------------------------------------------------------------------
PWR-3KW-AC-V2        DT-PriMCU                  NO      6.01      6.01      1.0 
                     DT-Sec54vMCU               NO      6.01      6.01      1.0 
                     DT-Sec5vMCU                NO      6.03      6.03      1.0 
                     EM-Sec54vMCU               NO      3.08      3.08      0.2 
                     EM-Sec5vMCU                NO      3.06      3.06      0.2 
--------------------------------------------------------------------------------
PROTO-CXP-1XPITA     BAO-MB FPGA                NO      1.00      1.00      0.0 
                     Slice-1 GN2411             YES     3.01      3.01      2.0 
                     Slice-1 GN2411             YES     2.07      2.07      0.0 
                     CCC FPGA                   YES     1.14      1.14      0.0 
                     CCC Power-On               YES     1.30      1.30      0.0 
                     Ethernet Switch            YES     1.32      1.32      0.0 
                     BIOS FPD                   YES     9.10      9.10      0.0 
                     SB Certificates            NO      1.00      1.00      0.0 
--------------------------------------------------------------------------------

show logging

To display the contents of the logging buffer, use the show logging command in System Admin EXEC mode.

show logging [local location node-id | onboard {fpd | inventory | temperature | uptime | voltage}]

Syntax Description

location node-id

(Optional) Displays system logging (syslog) messages from the specified local buffer. The node-id argument is expressed in the rack/ slot notation.

onboard

Displays onboard failure logging (OBFL) logging data.

fpd

Displays OBFL FPD data.

inventory

Displays OBFL inventory data.

temperature

Displays OBFL temperature data.

uptime

Displays OBFL uptime data.

voltage

Displays OBFL voltage data.

Command Default

None

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Use the show logging command to display the state of syslog error and event logging on the processor console. The information from the command includes the types of logging enabled and the size of the buffer.

Examples

This example shows a sample output from the show logging command:

sysadmin-vm:0_RP0#show logging local location 0/3

************************************************************
@Location : 0/3
************************************************************

Warning: Permanently added '192.0.76.1' (RSA) to the list of known hosts.
NULL:Jan  1 00:01:03.431 : cm[1733]: %ROUTING-TOPO-6-BAD_SVC_INFO : Bad service info from DS
NULL:Jan  1 00:01:13.073 : esd[1738]: %INFRA-ESD-6-SWITCH_OPERATIONAL : All configuraion is complete and switch is fully operational
NULL:Jan  1 00:01:15.471 : envmon[1737]: %INFRA-FM-4-FAULT_MINOR : ALARM_MINOR :I2C Access error :DECLARE :(null): MB Outlet has raised an alarm for I2C access error
NULL:Jan  1 00:01:15.988 : cm[1733]: %ROUTING-ISIS-4-ERR_BAD_PDU_FORMAT : L2 LAN IIH received from eth-vf1.3073 SNPA e050.72f4.e803 contains a format error: Unknown TLV at packet offset 48 overflows end of packet (length 51; space available 7)
NULL:Jan  1 00:01:18.909 : envmon[1737]: %INFRA-FM-4-FAULT_MINOR : ALARM_MINOR :I2C Access error :DECLARE :(null): HotSpot has raised an alarm for I2C access error
NULL:Jan  1 00:01:18.910 : envmon[1737]: %INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Sensor fault alarm :DECLARE :(null): multiple sensor faults
NULL:Jan  1 00:01:28.392 : envmon[1737]: %INFRA-FM-4-FAULT_MINOR : ALARM_MINOR :I2C Access error :CLEAR :(null): MB Outlet has cleared an alarm for I2C access error
NULL:Jan  1 00:01:28.393 : envmon[1737]: %INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Sensor fault alarm :CLEAR :(null): multiple sensor faults cleared
NULL:Jan  1 00:01:29.404 : envmon[1737]: %INFRA-FM-4-FAULT_MINOR : ALARM_MINOR :I2C Access error :CLEAR :(null): HotSpot has cleared an alarm for I2C access error
NULL:Jan  1 00:02:13.537 : cm[1733]: %ROUTING-TOPO-6-LEAD : Lead type: System lead System: e050.72f4.df03.
NULL:Jan  1 00:02:16.673 : sdr_mgr[1744]: 0/3:Jan  1 00:02:20.502 : slice_manager[1747]: %INFRA-SLICE-6-CLOCKING_ERR : Slice 1 : Detected loss of lock
0/3:Jan  1 00:02:36.705 : vm_manager[1751]: %INFRA-VM_MANAGER-4-INFO : Info: vm_manager started VM default-sdr--1

show parser dump

To display the command-line interface (CLI) syntax options for all command modes or for a specified command mode, use the show parser dump command in System Admin EXEC mode.

show parser dump

Syntax Description

This command has no keywords or arguments.

Command Default

Displays CLI options for all command modes.

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Output for this command shows the syntax options for all commands available in the specified mode.

Examples

This example shows a sample output from the show parser dump command:

sysadmin-vm:0_RP0#show parser dump

ccc_console ccc_console location WORD
clear controller fabric counter plane all
clear controller fabric statistics plane all
clear controller switch fdb location [0/1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/F0/F1/F2/F3] [Unknown/RP0/RP1/SC0/SC1/LC0/LC1/LC2/LC3/LC4/LC5/LC6/LC7/LC8/LC9/LC10/LC11/LC12/LC13/LC14/LC15/LC16/LC17/LC18/LC19] [RP-SW/SC-SW/LC-SW/F-SW0/F-SW1/Unknown] all
clear controller switch mlap statistics location [0/1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/F0/F1/F2/F3] [Unknown/RP0/RP1/SC0/SC1/LC0/LC1/LC2/LC3/LC4/LC5/LC6/LC7/LC8/LC9/LC10/LC11/LC12/LC13/LC14/LC15/LC16/LC17/LC18/LC19] [RP-SW/SC-SW/LC-SW/F-SW0/F-SW1/Unknown] all
clear controller switch sdr statistics location [0/1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/F0/F1/F2/F3] [Unknown/RP0/RP1/SC0/SC1/LC0/LC1/LC2/LC3/LC4/LC5/LC6/LC7/LC8/LC9/LC10/LC11/LC12/LC13/LC14/LC15/LC16/LC17/LC18/LC19] [RP-SW/SC-SW/LC-SW/F-SW0/F-SW1/Unknown] all
clear controller switch statistics location [0/1/2/3/4/5/6/7/8/9/10/11/12/13/14/15/F0/F1/F2/F3] [Unknown/RP0/RP1/SC0/SC1/LC0/LC1/LC2/LC3/LC4/LC5/LC6/LC7/LC8/LC9/LC10/LC11/LC12/LC13/LC14/LC15/LC16/LC17/LC18/LC19] [RP-SW/SC-SW/LC-SW/F-SW0/F-SW1/Unknown] all
clear history
clock read-calendar
clock set time WORD
clock update-calendar
.
.
.

show rack-inventory

To displays the System Admin Manager rack inventory, use the show rack-inventory command in the System Admin EXEC mode.

show rack-inventory [location node-id]

Syntax Description

location node-id

Specifies the target location. The node-id argument is expressed in the rack/ slot notation.

Command Default

Displays rack information for all the cards in the system.

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Used only for RP and LC cards.

Examples

This example shows sample output from the show rack-inventory command:

sysadmin-vm:0_RP0# show rack-inventory
Fri Aug  2  06:53:39.250 UTC
rack-inventory location 0/3
 FMP12160201
  rack_number 0
rack-inventory location 0/RP0
 FMP12160201
  rack_number 0
rack-inventory location 0/RP1
 FMP12160201
  rack_number 0

show user

To display different users logged-in to the System Admin plane, use the show user command in System Admin EXEC mode.

show user

Syntax Description

This command has no keywords or arguments.

Command Default

None

Command Modes

System Admin EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

Use the show user command to display different users logged-in to the System Admin plane of the router.

Examples

This example shows the sample output of the show user command:

sysadmin-vm:0_RP0#show user

Session User Context From              Date     Mode
*245    maya cli     127.0.0.1 Console 10:36:42 operational

show version

To display the software version, BIOS version, and build details, use the show version command in System Admin EXEC and XR EXEC modes.

show version

Syntax Description

This command has no keywords or arguments.

Command Default

None

Command Modes

System Admin EXEC

XR EXEC

Command History

Release Modification
Release 5.0.0

This command was introduced.

Usage Guidelines

The show version command displays a variety of system information, including hardware and software version, router uptime, and active software.

Examples

This example shows partial output from the show version command:

sysadmin-vm:0_RP0# show version 

Cisco IOS XR Admin Software, Version 5.0.0.40I
Copyright (c) 2013 by Cisco Systems, Inc.

Build Information:
 Built By     : palwal
 Built On     : Tue Sep 10 07:13:26 PDT 2013
 Build Host   : iox-bld4
 Workspace    : /auto/iox-bld4-scratch2/calvados-40thr
 Version      : 5.0.0.40I
 Location     : /opt/cisco/calvados/packages/

BIOS Version  : 9.10

System uptime is 14 hours, 31 minutes