Monitor Performance

Performance monitoring (PM) parameters are used by service providers to gather, store, set thresholds for, and report performance data for early detection of network issues. You can configure and retrieve PM counters for the various controllers in flex-bin, 30-second, 15-minute, or 24-hour intervals. These parameters simplify troubleshooting operations and enhance data that can be collected directly from the equipment.

Monitor Performance

You can set and retrieve PM counters for the OTS, OTS-OCH, OSC, DFB, OCH, and OMS controllers for various intervals.

The OCH and OMS controllers are created when the Mux/Demux panel and breakout panels are powered up using the USB 2.0 connection from the NCS 1010 EITU card. You can only view the current and historical PM parameters for the panels. You cannot configure the PM parameters for these controllers.

This table lists the PM parameters, their descriptions, and precision levels.

Table 1. PM Parameters for Controllers

PM Parameter (Unit of Measure)

Description

Resolution

OPT [dBM]

Total Tx(C+OSC) power

1/100

OPR [dBM]

Total Rx(C+OSC) power

1/100

OPT(C+L) [dBM]

Total Tx(C+L+OSC) power

1/100

OPR(C+L) [dBM]

Total Rx(C+L+OSC) power

1/100

OPR(S) [dBM]

C Band Received Signal Power

1/100

OPT(S) [dBM]

C Band Transmitted Signal Power

1/100

OPBR [dBM]

Back Reflection Power

1/100

EAGN [dB]

Egress Amplifier Gain

1/100

EATL [dB]

Egress Amplifier Tilt

1/100

IAGN [dB]

Ingress Amplifier Gain

1/100

IATL [dB]

Ingress Amplifier Tilt

1/100

RAMAN-TOT [mW]

Raman Total Pump power

1/10

RAMAN-1 [mW]

Raman 1 Pump power

1/10

RAMAN-2 [mW]

Raman 2 Pump power

1/10

RAMAN-3 [mW]

Raman 3 Pump power

1/10

RAMAN-4 [mW]

Raman 4 Pump power

1/10

RAMAN-5 [mW]

Raman 5 Pump power

1/10

The following tables list the maximum and minimum thresholds that can be set for the PM parameters for OLT nodes

Table 2. PM Thresholds for OLT OTS Controller (0/0/0/0)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–2000

4000

OPR

–3000

1800

OPT(C+L)

–2000

6085

OPR(C+L)

–3000

3600

OPR(S)

–3000

1800

OPT(S)

–500

2800

OPBR

–3000

–1400

EAGN

1390

3100

EATL

–500

500

IAGN

1030

3800

IATL

–500

500

RAMAN-TOT

2000

14100

RAMAN-1

450

3900

RAMAN-2

400

3900

RAMAN-3

400

2200

RAMAN-4

400

2200

RAMAN-5

350

1900

Table 3. PM Thresholds for OLT OTS Controller (0/0/0/2 and 0/0/0/3)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–3000

1500

OPR

–2500

1800

IAGN

1300

1900

IATL

–500

500

Table 4. PM Thresholds for OLT OTS Controller (0/0/0/4 to 0/0/0/33)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–3000

1500

OPR

–1500

1000

Table 5. PM Thresholds for OLT OTS-OCH Controller

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–3000

1500

OPR

–3000

1500

Table 6. PM Thresholds for OLT OSC Controller (0/0/0/0)

Parameter

Threshold Min

Threshold Max

OPT

–2000

1200

OPR

–3000

0

Table 7. PM Thresholds for OLT DFB Controller (0/0/0/0)

PM Parameter

Minimum Threshold

MaximumThreshold

OPT

–2000

1000

OPR

–3000

1500

The following tables list the maximum and minimum thresholds that can be set for the PM parameters for ILA nodes.

Table 8. PM Thresholds for ILA OTS Controller (0/0/0/0)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–3000

4000

OPR

–3000

2000

OPT(C+L)

–3000

6085

OPR(C+L)

–3000

4000

OPR(S)

–3000

2800

OPT(S)

–3000

2000

OPBR

–3000

–1400

EAGN

590

3600

EATL

–500

500

RAMAN-TOT

2000

14100

RAMAN-1

450

3900

RAMAN-2

400

3900

RAMAN-3

400

2200

RAMAN-4

400

2200

RAMAN-5

350

1900

Table 9. PM Thresholds for ILA OTS Controller (0/0/0/2)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–3000

4000

OPR

–3000

2000

OPT(C+L)

–3000

6085

OPR(C+L)

–3000

4000

OPR(S)

–3000

2800

OPT(S)

–3000

2000

OPBR

–3000

–1400

EAGN

590

3600

EATL

–500

500

RAMAN-TOT

2000

14100

RAMAN-1

450

3900

RAMAN-2

400

3900

RAMAN-3

400

2200

RAMAN-4

400

2200

RAMAN-5

350

1900

Table 10. PM Thresholds for ILA OSC Controller (0/0/0/0 and 0/0/0/2)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–2000

1200

OPR

–3000

0

Table 11. PM Thresholds for ILA OTS-OCH Controllers

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–3000

1500

OPR

–3000

1500

Table 12. PM Thresholds for ILA DFB Controllers (0/0/0/0 and 0/0/0/2)

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–2000

1000

OPR

–3000

1500

This table lists the maximum and minimum thresholds that are set for the PM parameters for OCH controllers.

Table 13. PM Thresholds for OCH Controllers

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–30

15

OPR

–30

15

This table lists the maximum and minimum thresholds that are set for the PM parameters for OMS controllers.

Table 14. PM Thresholds for OMS Controllers

PM Parameter

Minimum Threshold

Maximum Threshold

OPT

–30

15

OPR

–30

15

Photo Diodes (PDs) Refresh Rate

Table 15. Feature History

Feature Name

Release Information

Feature Description

Improved Performance Monitoring

Cisco IOS XR Release 7.11.1

NCS 1010 now measures the power values of Photo Diodes (PDs) at various measurement points at a faster refresh rate to improve the node performance monitoring. With the upgraded FPDs, the refresh rate has reduced from 250 ms to 50 ms. This faster refresh rate applies to all the NCS 1010 PIDs for the following line card FPDs:

  • ILA

  • OLT

  • Raman-1

  • Raman-2

NCS 1010 measures the power values of Photo Diodes (PDs) at various measurement points to provide values for PM parameters. The measured values are refreshed at a defined rate for the latest values.

From Release 7.11.1, the rate at which the values of specific PDs are refreshed is reduced from 250 ms to 50 ms. This faster refresh rate is applicable to all the NCS 1010 OLT and ILA PIDs.

The following table provides the list of photo diodes that support the new refresh rate of 50 ms.

Table 16. Line Cards and Impacted PDs
Line Cards PDs
OLT-C PD1, PD9, PD14, PD20
OLT-L PD1, PD9, PD11, PD15
ILA-C PD1, PD3, PD5, PD7, PD13, PD14, PD21, PD22
ILA-L PD1, PD3, PD5, PD7, PD9, PD10, PD17, PD18
OLT and ILA cards with RAMAN PD2, PD7

In the OLT-C card, the newer refresh rate impacts the following PM parameters and controllers.

Photo Diode

Controller

PM Parameter

PD1

OTS

OPR-S

PD9

OSC

OPR

PD9

OTS

OPR

PD14

OTS

OPT-S

PD20

OSC

OPT

PD20

OTS

OPT

In the ILA-C card, the newer refresh rate impacts the following PM parameters and controllers.

Photo Diodes

Controller

PM Parameter

PD1, PD3

OTS

OPR-S

PD5, PD7

OSC

OPR

PD13, PD14

OTS

OPT-S

PD21, PD22

OSC

OPT

Configure and View PM Parameters

You can configure the performance monitoring parameters for the controllers. To configure PM parameters, use the following commands in the configuration mode:

Table 17. Feature History

Feature Name

Release Information

Feature Description

Threshold Crossing Alert (TCA) for Span Loss

Cisco IOS XR Release 7.11.1

You can now activate TCA reporting and set specific minimum and maximum threshold values for both Tx and Rx span loss across all time intervals.

This enhancement provides prompt notifications for deviations from normal span loss values, which can be viewed using the show alarms brief system active command.

To implement this feature, two new parameters slr-cl and slt-cl have been introduced for the pm command.

Additionally, the output of the show controllers ots R/S/I/P pm command now captures both the actual and configured threshold values for span loss.

Table 18. Feature History

Feature Name

Release Information

Feature Description

PM History Persistence

Cisco IOS XR Release 7.11.1

PM history parameters for Optics, Ethernet, and coherent DSP controllers are now retained even after the occurrence of an operation disruptive event like:

  • Various reloads

  • Power cycle

  • System upgrade

This functionality maintains prolonged access to performance history for extended device health monitoring and assessment

controller controllertype R/S/I/P { pm { 15-min | 24-hour | 30-sec | flex-bin } { optics | ots } { report | threshold } { opr | opt | eagn | eatl | iagn | iatl | slr-cl | slt-cl | opbr | opr | opr-cl | opr-s | opt | opt-cl | opt-s | raman-1 | raman-2 | raman-3 | raman-4 | raman-5 | raman-tot } { max-tca | min-tca } {enable | value }

Examples

The following example enables the maximum and minimum Threshold Crossing Alert (TCA) reporting on the OTS controller for a 15 minute interval on a C+L band network. The sample also configures the maximum and minimum Rx span loss threshold to 36db and 33db respectively. These values are compared against the current maximum span loss value to determine if a TCA should be generated.

RP/O/RPO/CPUO:ios#config
RP/O/RPO/CPUO:ios(config)#controller pts 0/0/0/0 pm 15-min ots report slr-cl max-tca enable
RP/0/RPO/CPUO:ios(config)#controller pts 0/0/0/0 pm 15-min ots threshold slr-cl max 3600
RP/O/RPO/CPUO:ios(config)#controller pts 0/0/0/0 pm 15-min ots report slr-cl min-tca enable
RP/0/RPO/CPUO:ios(config)#controller pts 0/0/0/0 pm 15-min ots threshold slr-cl min 3300
RP/0/RP0/CPU0:ios(config)#commit
RP/0/RP0/CPU0:ios(config)#end
The following example shows the TOT-SPAN-LOSS-TX-CL-MAX alert is triggered when the current TX span loss value exceeds the maximum TX span loss threshold:
RP/0/RP0/CPU0:P1D_DT_04#show alarms brief system conditions | include SPAN
Thu Oct  5 04:49:21.462 UTC
0/0             NotAlarmed   Controller       10/05/2023 04:49:00 UTC    Ots0/0/0/0 -  Threshold Crossing Alert For TOT-SPAN-LOSS-TX-CL-MAX In 30 Second Bucket
The following example sets the reporting status to maximum TCA for the eagn parameter of the OTS controller for a 15-minute interval.

RP/0/RP0/CPU0:ios#config
RP/0/RP0/CPU0:ios(config)#controller ots 0/0/0/0 pm 15-min ots report eagn max-tca enable
RP/0/RP0/CPU0:ios(config)#commit
RP/0/RP0/CPU0:ios(config)#end

The following example configures the maximum threshold for the eagn parameter of the OTS controller to 20 dB.


Note


The OTS controller commands accept PM parameter values in two decimal places. In this example, the eagn parameter is entered as 2000 to configure the eagn parameter to 20 dB.


RP/0/RP0/CPU0:ios#config
RP/0/RP0/CPU0:ios(config)#controller ots 0/0/0/0 pm 15-min ots threshold eagn max 2000
RP/0/RP0/CPU0:ios(config)#commit
RP/0/RP0/CPU0:ios(config)#end

To view the current PM parameters on an OTS controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers ots 0/0/0/0 pm current 15-min optics 1

The following output shows the current PM parameters on an OTS controller for a 15-minute interval and highlights the maximum threshold set for the eagn parameter that is configured for 20 dB.

Tue May 17 06:37:00.529 UTC

Optics in the current interval [06:30:00 - 06:37:00 Tue May 17 2022]

Optics current bucket type : Valid
             MIN       AVG       MAX     Operational  Configured    TCA   Operational   Configured  TCA
                                        Threshold(min)Threshold(min(min) Threshold(max)Threshold(max(max)
OPT[dBm]     : 20.00     20.00     20.00    -20.00     NA           NO   40.00         NA           NO
OPR[dBm]     : 20.00     20.00     20.00    -30.00     NA           NO   18.00         NA           NO
OPT(C+L)[dBm]: 20.00     20.00     20.00    -20.00     NA           NO   60.85         NA           NO
OPR(C+L)[dBm]: -10.00    -10.00    -10.00   -30.00     NA           NO   36.00         NA           NO
OPT(S)[dBm]  : 20.00     20.00     20.00    -5.00      NA           NO   28.00         NA           NO
OPR(S)[dBm]  : 20.00     20.00     20.00    -30.00     NA           NO   18.00         NA           NO
OPBR[dBm]    : -30.00    -30.00    -30.00   -30.00     NA           NO   -14.09        NA           NO
EAGN[dB]     : 30.00     30.00     30.00    16.00      NA           NO   20.00         20.00        YES
EATL[dB]     : -4.80     -4.80     -4.80    -5.00      NA           NO   5.00          NA           NO
IAGN[dB]     : 25.00     25.00     25.00    12.00      NA           NO   25.00         NA           NO
IATL[dB]     : -2.40     -2.40     -2.40    -5.00      NA           NO   5.00          NA           NO
RAMAN-TOT[mW]: 300.00    300.00    300.00   200.00     NA           NO   1410.00       NA           NO
RAMAN-1 [mW] : 45.00     45.00     45.00    45.00      NA           NO   390.00        NA           NO
RAMAN-2 [mW] : 40.00     40.00     40.00    40.00      NA           NO   390.00        NA           NO
RAMAN-3 [mW] : 40.00     40.00     40.00    40.00      NA           NO   220.00        NA           NO
RAMAN-4 [mW] : 40.00     40.00     40.00    40.00      NA           NO   220.00        NA           NO
RAMAN-5 [mW] : 35.00     35.00     35.00    35.00      NA           NO   190.00        NA           NO

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters on an OTS controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers ots 0/0/0/0 pm history 15-min optics  1 bucket 1

The following output shows the historical PM parameters on an OTS controller for a 15-minute interval.

Tue May 17 07:02:26.911 UTC

Optics in interval 1 [06:45:00 - 07:00:00 Tue May 17 2022]

Optics history bucket type : Valid
                MIN       AVG       MAX
OPT[dBm]   :   20.00      20.00     20.00
OPR[dBm]   :   20.00      20.00     20.00
OPT(C+L)[dBm]: 20.00      20.00     20.00
OPR(C+L)[dBm]: -10.00    -10.00    -10.00
OPT(S)[dBm]  : 20.00      20.00     20.00
OPR(S)[dBm]  : 20.00      20.00     20.00
OPBR[dBm]    : -30.00    -30.00    -30.00
EAGN[dB]     : 30.00     30.00     30.00
EATL[dB]     : -4.80     -4.80     -4.80
IAGN[dB]     : 25.00     25.00     25.00
IATL[dB]     : -2.40     -2.40     -2.40
RAMAN-TOT[mW]: 300.00    300.00    300.00
RAMAN-1 [mW] : 45.00     45.00     45.00
RAMAN-2 [mW] : 40.00     40.00     40.00
RAMAN-3 [mW] : 40.00     40.00     40.00
RAMAN-4 [mW] : 40.00     40.00     40.00
RAMAN-1 [mW] : 35.00     35.00     35.00

To view the current PM parameters on an OTS-OCH controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers ots-och 0/0/0/0/1 pm current 15-min optics 1

The following output shows the current PM parameters on an OTS-OCH controller for a 15-minute interval.

Tue May 17 10:27:20.387 UTC

Optics in the current interval [10:15:00 - 10:27:20 Tue May 17 2022]

Optics current bucket type : Valid
           MIN  AVG   MAX Operational    Configured      TCA      Operational    Configured     TCA  
                          Threshold(min)  Threshold(min) (min)   Threshold(max)   Threshold(max) (max)
OPT[dBm] : 1.20 1.30   1.30     -30.00            NA            NO         15.00         NA      NO
OPR[dBm] :-12.31-12.25-12.20    -30.00            NA            NO         15.00         NA      NO
Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters on an OSC controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controller osc 0/0/0/0 pm current 15-min optics 1

The following output shows the current PM parameters on an OSC controller for a 15-minute interval.

Tue May 17 08:24:32.642 UTC

Optics in the current interval [08:15:00 - 08:24:32 Tue May 17 2022]

Optics current bucket type : Valid
             MIN       AVG       MAX      Operational      Configured      TCA   Operational Configured     TCA
                                          Threshold(min)   Threshold(min) (min) Threshold(max)Threshold(max)(max)
OPT[dBm]     : -10.00    -10.00    -10.00   -20.00            NA           NO   12.00            NA           NO
OPR[dBm]     : -30.00    -30.00    -30.00   -30.00            NA           NO   0.00             NA           NO

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters on a DFB controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controller dfb 0/0/0/0 pm current 15-min optics 1

The following output shows the current PM parameters on a DFB controller for a 15-minute interval.

Tue May 17 08:28:37.455 UTC

Optics in the current interval [08:15:00 - 08:28:37 Tue May 17 2022]

Optics current bucket type : Valid
          MIN   AVG  MAX   Operational Configured    TCA   Operational Configured     TCA
                           Threshold  Threshold            Threshold    Threshold
                             (min)      (min)        (min)    (max)         (max)     (max)
OPT[dBm]: 20.00 20.00 20.00   -25.23     NA         NO    18.00            NA          NO
OPR[dBm]: 10.00 10.00 10.00   -30.00     NA         NO    12.00            NA          NO

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters for an OCH controller for a 30-second interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers och 0/1/0/0 pm current 30-sec optics 1

The following output shows the current PM parameters for an OCH controller for a 30-second interval.

Tue May 10 11:28:29.896 UTC

Optics in the current interval [11:28:00 - 11:28:29 Tue May 10 2022]

Optics current bucket type : Valid
             MIN       AVG       MAX      Operational      Configured      TCA   Operational      Configured     TCA
                                          Threshold(min)   Threshold(min) (min) Threshold(max)   Threshold(max) (max)
OPT[dBm]     : -50.00    -50.00    -50.00   -30.00            NA              NO   15.00            NA              NO   
OPR[dBm]     : -50.00    -50.00    -50.00   -30.00            NA              NO   15.00            NA              NO   

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters on an OCH controller for a 30-second interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers och 0/1/0/0 pm history 30-sec optics 1 bucket 1

The following output shows the historical PM parameters on an OCH controller for a 30-second interval.

Mon Jul 25 05:35:52.176 UTC

Optics in interval 1 [05:35:00 - 05:35:30 Mon Jul 25 2022]

Optics history bucket type : Valid
              MIN       AVG       MAX 
OPT[dBm]   : -50.00    -50.00    -50.00 
OPR[dBm]   : -50.00    -50.00    -50.00 

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters for an OCH controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers och 0/1/0/0 pm current 15-min optics 1

The following output shows the current PM parameters for an OCH controller for a 15-minute interval.

Tue May 10 11:28:50.952 UTC

Optics in the current interval [11:15:00 - 11:28:50 Tue May 10 2022]

Optics current bucket type : Valid
             MIN       AVG       MAX      Operational      Configured      TCA   Operational      Configured     TCA
                                          Threshold(min)   Threshold(min) (min) Threshold(max)   Threshold(max) (max)
OPT[dBm]     : -50.00    -50.00    -50.00   -30.00            NA              NO   15.00            NA              NO
OPR[dBm]     : -50.00    -50.00    -50.00   -30.00            NA              NO   15.00            NA              NO

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters for an OCH controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers och 0/1/0/0 pm history 15-min optics 1 bucket 1

The following output shoes the historical PM parameters for an OCH controller for a 15-minute interval.

Mon Jul 25 05:36:12.167 UTC

Optics in interval 1 [05:15:00 - 05:30:00 Mon Jul 25 2022]

Optics history bucket type : Valid
              MIN       AVG       MAX 
OPT[dBm]   : -50.00    -50.00    -50.00 
OPR[dBm]   : -50.00    -50.00    -50.00 

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters on an OCH controller for a 24-hour interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers och 0/1/0/0 pm current 24-hour optics 1

The following output shoes the current PM parameters on an OCH controller for a 24-hour interval.

Tue May 10 11:29:09.270 UTC

Optics in the current interval [00:00:00 - 11:29:09 Tue May 10 2022]

Optics current bucket type : Invalid
             MIN       AVG       MAX      Operational      Configured      TCA   Operational      Configured     TCA
                                          Threshold(min)   Threshold(min) (min) Threshold(max)   Threshold(max) (max)
OPT[dBm]     : -50.00    -50.00    -50.00   -30.00            NA              NO   15.00            NA              NO
OPR[dBm]     : -50.00    -50.00    -50.00   -30.00            NA              NO   15.00            NA              NO

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters on an OCH controller for a 24-hour interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers och 0/1/0/0 pm history 24-hour optics 1

he following output shows the historical PM parameters on an OCH controller for a 24-hour interval.

Mon Jul 25 05:36:35.165 UTC

Optics in interval 1 [00:00:00 - 24:00:00 Sun Jul 24 2022]

Optics history bucket type : Valid
              MIN       AVG       MAX 
OPT[dBm]   : -50.00    -50.00    -50.00 
OPR[dBm]   : -50.00    -50.00    -50.00 

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters for an OMS controller for a 30-second interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/8 pm current 30-sec optics 1

The following output shows the current PM parameters for an OMS controller for a 30-second interval.

Mon Jul 25 07:24:38.319 UTC

Optics in the current interval [07:24:30 - 07:24:38 Mon Jul 25 2022]

Optics current bucket type : Valid
MIN AVG MAX Operational Configured TCA Operational Configured TCA
Threshold(min) Threshold(min) (min) Threshold(max) Threshold(max) (max)
OPT[dBm] : -50.00 -50.00 -50.00 -30.00 NA NO 15.00 NA NO
OPR[dBm] : -50.00 -50.00 -50.00 -30.00 NA NO 15.00 NA NO

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters on an OMS controller for a 30-second interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/8  pm history 30-sec optics 1 bucket 1

The following shows the historical PM parameters on an OMS controller for a 30-second interval.

Mon Jul 25 07:13:51.228 UTC

Optics in interval 1 [07:13:00 - 07:13:30 Mon Jul 25 2022]

Optics history bucket type : Valid
              MIN       AVG       MAX 
OPT[dBm]   : -50.00    -50.00    -50.00 
OPR[dBm]   : -50.00    -50.00    -50.00 

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters for an OMS controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/8 pm current 15-min optics 1

The following output shows the current PM parameters for an OMS controller for a 15-minute interval.

Mon Jul 25 07:25:00.183 UTC

Optics in the current interval [07:15:00 - 07:25:00 Mon Jul 25 2022]

Optics current bucket type : Valid
MIN AVG MAX Operational Configured TCA Operational Configured TCA
Threshold(min) Threshold(min) (min) Threshold(max) Threshold(max) (max)
OPT[dBm] : -50.00 -50.00 -50.00 -30.00 NA NO 15.00 NA NO
OPR[dBm] : -50.00 -50.00 -50.00 -30.00 NA NO 15.00 NA NO

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters for an OMS controller for a 15-minute interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/8  pm history 15-min optics 1 bucket 1

The following output shows the historical PM parameters for an OMS controller for a 15-minute interval.

Mon Jul 25 07:14:03.090 UTC

Optics in interval 1 [06:45:00 - 07:00:00 Mon Jul 25 2022]

Optics history bucket type : Valid
              MIN       AVG       MAX 
OPT[dBm]   : -50.00    -50.00    -50.00 
OPR[dBm]   : -50.00    -50.00    -50.00 

Last clearing of "show controllers OPTICS" counters never

To view the current PM parameters on an OMS controller for a 24-hour interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/8 pm current 24-hour optics 1

The following output shows the historical PM parameters for an OMS controller for a 15-minute interval.

Mon Jul 25 07:26:09.817 UTC

Optics in the current interval [00:00:00 - 07:26:09 Mon Jul 25 2022]

Optics current bucket type : Valid
MIN AVG MAX Operational Configured TCA Operational Configured TCA
Threshold(min) Threshold(min) (min) Threshold(max) Threshold(max) (max)
OPT[dBm] : -50.00 -50.00 -50.00 -30.00 NA NO 15.00 NA NO
OPR[dBm] : -50.00 -50.00 -50.00 -30.00 NA NO 15.00 NA NO

Last clearing of "show controllers OPTICS" counters never

To view the historical PM parameters on an OMS controller for a 24-hour interval, use the following command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/8 pm history 24-hour optics 1

The following output shows the historical PM parameters on an OMS controller for a 24-hour interval.

Mon Jul 25 07:18:13.532 UTC

Optics in interval 1 [00:00:00 - 24:00:00 Sun Jul 24 2022]

Optics history bucket type : Valid
              MIN       AVG       MAX 
OPT[dBm]   : -50.00    -50.00    -50.00 
OPR[dBm]   : -50.00    -50.00    -50.00 

Last clearing of "show controllers OPTICS" counters never

PM History Persistence

PM history parameters are retained even after a line card cold reload, line card warm reload, rack reload, RP reload, power cycle, or upgrade of the NCS 1010 chassis.


Note


PM history persistence is not supported on NCS1K4-QXP-K9.


After a software upgrade to the latest release, you can view the history performance monitoring parameters from the previous release. The PM history persistence is supported for 30-second, 15-minute, and 24-hour bucket types. After upgrade from Release 7.11.1 to a higher version, if new PM parameters are available in the new version, below error is displayed while fetching PM data.

RP/0/RP0/CPU0:ios#show controllers hundredGigECtrlr 0/0/0/8 pm history 15-min ether 5
Tue Apr  5 22:05:56.750 UTC
pm_display_int_15min_ether_index: bag_decode failed ('bag' detected the 'fatal' condition 'An irresolvable version conflict prevented the specified bag from being decoded')

However, the following list describes the time that is required to fill all historical buckets of each bucket type, later while fetching PM historical data, no error appears.

  • For 30-second bucket type, 15 minutes is required to fill 30 historical buckets.

  • For 15-minute bucket type, 8 hours is required to fill 32 historical buckets.

  • For 24-hour bucket type, 24 hours is required to fill 7 historical bucket.

PM counters are updated continuously in current bucket for all bucket types (flex, 30-second, 15-minute, and 24-hour). After the timer expires for the respective bucket type, the current PM data is moved to the historical PM bucket. This process of moving PM data to the historical bucket is called Rollover. After rollover, you can access the current PM data as historical PM data.

In case of deletion or removal of the controller, the PM data is persistent for 3 hours. Unless the controller is brought up within 3 hours, the PM data is cleared because the controller is considered to be not in use.

Limitations

If NCS 1010 reload or software upgrade happens during the rollover time, one of the following scenarios occurs:

  • The complete PM bucket is missing and the next PM bucket is marked as Invalid.

  • PM bucket expiry message appears as follows:

    RP/0/RP0/CPU0:ios#show controllers hundredGigECtrlr 0/3/0/2 pm history 30-sec ether 29
    Fri Apr  1 01:32:20.646 UTC
    History data is empty, Verify at least one collection period is expired
    
  • PM bucket interval is marked as Invalid and counters are updated as zero.

  • PM bucket interval is marked as Invalid and counters are updated as nonzero.