Step 4 |
On the Reconfiguring Optional Feature through UM page of the Cisco VIM UM, enter the data for the following fields:
Name
|
Description
|
Heat check box
|
-
Enable Heat.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Enable Read-only OpenStack Admins checkbox
|
When Offline Validation is successful, click Reconfigure to commence the process.
|
Keystone v3 check box
|
-
Enable Keystone v3.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
ENABLE_ESC_PRIV
|
-
Enable ENABLE_ESC_PRIV .
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Autobackup check box
|
-
Enable/Disable Autobackup.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
External LB VIP TLS check box
|
-
Enable External LB VIP TLS.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
External LB VIP FQDN check box
|
-
Enter input as a string.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Pod Name
|
-
Enter Input as a string.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Tenant Vlan Ranges
|
-
Augment tenant vlan ranges input. For Example: 3310:3315.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Provider VLAN Ranges
|
-
Enter input to tenant vlan ranges. For Example: 3310:3315.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Install Mode
|
-
Select Connected or Disconnected, any one form the drop-down list.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
VAULT
|
-
Enable Vault, if it is not deployed on day 0.
-
Click Offline Validation
-
If offline validation is successful, click Reconfigure to commence the process.
|
Cloud Settings
|
Following are the options for Cloud Settimgs:
-
keystone_lockout_failure_attempts: Number of incorrect password attempts before the user is locked out. Values are 0 by default for no lockout, and can be
in the range of 0 to 10.
-
keystone_lockout_duration: Number of seconds a user is locked out. By default, it is 1800 for 30 minutes. Values are in the range of 300 (5 minutes)
to a maximum of 86400 (24 hours).
-
keystone_unique_last_password_count: Forces the user to change their password to a value not used before. Default is 0 for no history check.Values are in the
range of 0 to 10.
-
keystone_minimum_password_age: Restricts you to change their password at most every this many days. Default is 0 for no limit. Values are in the range
of 0 to 2.
-
horizon_session_timeout: Number of seconds of inactivity before Horizon dashboard is logged out. Default is 1800 for 30 minutes. Values are in the
range of 300 (5 minutes) to maximum of 86400 (24 hours).
Click Offline Validation. If Offline Validation is successful, click Reconfigure to commence the process.
|
Registry Setup Settings checkbox
|
For Registry Setup:
-
Enter the Registry User Name. It is a mandatory field
-
Enter the Registry Password. The minimum length of the password is three.
-
Enter the Registry Email. It is a mandatory field.
-
Enter the Registry Name. For example, Registry FQDN name. It is a mandatory field, only when Cisco VIM Software Hub is enabled.
-
Click Offline Validation
-
If offline validation is successful, click Reconfigure to commence the process.
.
|
Syslog Export Settings
|
Following are the options for Syslog Settings:
Remote Host
|
Enter Syslog IP Address.
|
Facility
|
Defaults to local5
|
Severity
|
Defaults to debug
|
Clients
|
Defaults to ELK
|
Port
|
Defaults to 514 but is modified by the User.
|
Protocol
|
Supports only UDP |
Click Offline Validation .
|
Configure ToR checkbox
|
True or False. Default is false.
|
ToR Switch Information
|
Click + to add information for ToR Switch.
Name
|
Description
|
Name
|
ToR switch name.
|
Username
|
ToR switch username.
|
Password
|
ToR switch Password.
|
SSH IP
|
ToR switch SSH IP Address.
|
SSN Num
|
ToR switch ssn num. output of show license host-id.
|
VPC Peer Keepalive
|
Peer Management IP. You need not define if there is no peer.
|
VPC Domain
|
Need not define if there is no peer.
|
VPC Peer port
|
Interface for vpc peer ports.
|
VPC Peer VLAN Info
|
vlan ids for vpc peer ports (optional).
|
BR Management Port Info
|
Management interface of the build node.
|
BR Management PO Info
|
Port channel number for the management interface of the build node.
|
Click Save
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Note
|
When setup data is ACI VLAN with TOR then reconfigure options are:
|
TORSwitch Information mandatory table if you want to enter ToR information
|
Click + to add information for ToR Switch.
Name
|
Description
|
Host Name
|
ToR switch name.
|
VPC Peer Keepalive
|
Peer Management IP.
|
VPC Domain
|
Do not define if there is no
|
Node ID
|
Integer, unique across all switches |
Click Save
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
NFVBench
|
Enable check box which by default is false.
Add ToR information connected to switch:
-
Select a ToR Switch and enter the Switch name.
-
Enter the port number. For example: eth1/5
-
NIC Ports: INT1 and INT2 optional input, enter the two port numbers of the 4-port 10G Intel NIC at the management node used for NFVBench.
For mechanism driver VPP, there are two optional fields in NFVBENCH if network option is available:
-
VTEP IPs: Mandatory for NFVBench with VXLAN. It must be comma separated IP pair in vxlan-tenant network, but not in the tenant pool.
-
VNIs: Mandatory for NFVBench with VXLAN, and must be comma separated vnid_id pairs.
For mechanism driver VTS:
VTEP IPs: Mandatory for VTS/VXLAN only. It must be comma separated IP pair belonging to tenant network segment, but not in the tenant
network pool.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
Note
|
If ToR is already present in setup-data or already deployed, Tor info need not be added. By default ToR information switch
name is mapped in NFV bench.
|
|
Swiftstack
SwiftStack is only supported with Keystone v2. If you select Keystone v3, swiftstack will not be available for configuration.
|
Cluster End Point
|
IP address of PAC (proxy-account-container) endpoint.
|
Admin User
|
Admin user for swift to authenticate in keystone.
|
Admin Tenant
|
The service tenant corresponding to the Account-Container used by Swiftstack.
|
Reseller Prefix
|
Reseller_prefix as configured for Keystone Auth,AuthToken support in Swiftstack E.g KEY_
|
Admin Password
|
swiftstack_admin_password
|
Protocol drop-down list
|
http or https
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
LDAP with Keystone v3
|
Domain Name field
|
Enter the Domain name.
|
Object Class for Users field
|
Enter a string as input.
|
Object Class for Groups
|
Enter a string.
|
Domain Name Tree for Users
|
Enter a string.
|
Domain Name Tree for Groups field
|
Enter a string.
|
Suffix for Domain Name field
|
Enter a string.
|
URL field
|
Enter a URL with port number.
|
Domain Name for Bind User field
|
Enter a string.
|
Password field
|
Enter Password as string format.
|
User Filter
|
Enter filter name as string.
|
User ID Attribute
|
Enter a string.
|
User Name Attribute
|
Enter a string.
|
User Mail Attribute
|
Enter a string.
|
Group Name Attribute
|
Enter a string.
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
NFVI Monitoring
|
Followings are the field values for NFVI monitoring:
Master Admin IP
|
Enter the input in IP format.
|
Master 2 Admin IP field.
|
Enter the input in IP format.
|
Collector Management IP
|
Enter the input in IP format.
|
Collector VM1 info |
|
Host Name field
|
Enter Host Name as a string.
|
CCUSER password field
|
Enter Password.
|
Password field
|
Enter password.
|
Admin IP field
|
Enter Input as IP format.
|
Management IP field
|
Enter Input as IP format.
|
|
|
Collector VM2 info |
|
Host Namefield
|
Enter a string.
|
CCUSER field
|
Enter Password.
|
Management IP field
|
Enter Input as IP format.
|
|
|
Dispatcher
|
|
Rabbit MQ Username Field
|
Enter a string.
|
NFVIMON_ADMIN |
Enter a single string. Can have only one and is optional. |
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
VTS Parameter
|
Following are the fields to reconfigure for VTS parameters
VTC SSH Username field.
|
Enter the string.
|
VTC SSH Username field.
|
Enter the password.
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
VMTP
|
Check one of the check boxes to specify a VMTP network:
-
Provider Network
-
External Network
For the Provider Network complete the following:
Network Name field.
|
Enter the name for the external network.
|
IP Start field.
|
Enter the starting floating IPv4 address.
|
IP End field.
|
Enter the ending floating IPv4 address.
|
Gateway field
|
Enter the IPv4 address for the Gateway.
|
DNS Server field.
|
Enter the DNS server IPv4 address.
|
Segmentation ID field.
|
Enter the segmentation ID.
|
Subnet
|
Enter the Subnet for Provider Network.
|
|
|
For External Network fill in the following details:
Network Name field.
|
Enter the name for the external network.
|
Network IP Start field.
|
Enter the starting floating IPv4 address.
|
Network IP End field.
|
Enter the ending floating IPv4 address.
|
Network Gateway field
|
Enter the IPv4 address for the Gateway.
|
DNS Server field.
|
Enter the DNS server IPv4 address.
|
Subnet
|
Enter the Subnet for External Network.
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Networking
In Reconfigure optional services networking, you can reconfigure IP tables, or add http_proxy/https_proxy.
|
To reconfigure networking, update the relevant information:
IP Tables
|
Click Add(+) to add a table. Enter input as subnet format.
E.g. 12.1.0.1/2
|
http_proxy_server
|
Enter HTTP_PROXY_SERVER
E.g. <a.b.c.d:port>
|
https_proxy_server
|
Enter HTTP_PROXY_SERVER
E.g. <a.b.c.d:port>
|
NTP Server
|
Click Add (+) to add server
-
You can delete or edit the entered value
-
You cannot delete all the data (minimum 1 server should be present)
-
Maximum of four NTP servers can be present.
|
Domain Name Server
|
Click Add (+) to add server
-
You can delete or edit the entered value.
-
You cannot delete all the data (minimum 1 server must be present)
-
Maximum of three DNS servers can be present.
|
Head-end replication
|
Add VTEP IP address and comma separated VNI IDs. Multiple entries are allowed. You can change VTEP IP for individual compute/control
servers.
Note
|
Whenever HER is removed from both vxlan-tenant and vxlan-tenant, all the vtep ips associated with the computes are removed.
|
|
Layer 3 BGP Adjacency
|
Applicable to control servers only when VXLAN is enabled in NETWORK OPTIONS.IPs are picked up from management subnet, but
not from IP pool. You can change the existing IP values if required.
|
-
Click Save.
-
Click Offline Validation.
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
APICINFO
Note
|
Reconfigure optional services only APIC hosts can be reconfigure.
|
|
To reconfigure APICINFO, follow the process:
-
Enter input for APIC hosts format. <ip1|host1>:[port] or eg.12.1.0.12
-
Click Save.
-
Click Offline Validation.
-
When Offline Validation is successful, click Reconfigure to commence the process.
Note
|
APIC hosts can be reconfigure minimum 1 host and max 3 but not 2 hosts.
|
|
Vim_admins
|
To reconfigure vim_admins, follow the process:
-
To add a new root user, Click + and add the Username and admin hash password (Starting with $6). At least, one Vim Admin must be configured, when Permit
root login is false.
-
To remove the existing user, Click -.
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Cobbler
|
To reconfigure Cobbler, follow the process:
-
Generate the admin password hash by executing the below command:
python -c 'import crypt; print crypt.crypt
("<plaintext_strong_password>")'
on the management node.
-
Validate that the admin_password_hash starts with '$6'
-
Enter Admin Password Hash.
-
Click Offline Validation.
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
ES Remote Backup
|
To reconfigure Elastic Search Remote Backup:
Service field displays NFS by default, if the remote NFS server is used.
-
Enter the Remote Host, which is IP of the NFS server.
-
Enter the Remote Path. . It is the path of the backup location in the remote server.
-
Click Offline Validation.
-
If Offline Validation is successful, click Reconfigure to commence the process.
|
CVIM-MON
|
To reconfigure CVIM-MON, enter the following details:
-
Enter the Low Frequency, such that it is higher than medium frequency. Minimum value is 1 minute. By default, it is set to 1 minute.
-
Enter the Medium Frequencysuch that it is more than high frequency. Minimum value is 30 seconds. By default, it is set to 30 seconds.
-
Enter the High Frequency such that the minimum value is 10 seconds. By default, it is set to 10 seconds.
-
Click Offline Validation.
-
If Offline Validation is successful, click Reconfigure to commence the process.
-
Set ui_access to True in deployed Blueprint, to enable the Cisco VIM monitor link. This property is reconfigurable. If set to False, the
link is disabled.
|
NETAPP_SUPPORT
|
To reconfigure NETAPP_SUPPORT, enter the following details:
-
Select the Server Port. It is the port of NetApp management or API server. Select 80 for HTTP and 443 for HTTPS.
-
Select the Transport Type of the NetApp management or API server. It can be HTTP or HTTPS.
-
Select the NetApp Cert Path. It is the root ca path for NetApp cluster, only if protocol is HTTPS.
-
Click Offline Validation.
-
If Offline Validation is successful, click Reconfigure to commence the process.
|
|