Connecting the Management Interfaces
Revised: August 23, 2010, OL-19897-02
Introduction
This chapter explains how to connect the SCE8000 GBE Service Control Module (SCE8000-SCM-E) to a local console and perform the initial system configuration via the setup wizard that runs automatically.
Additionally, this chapter contains instructions for cabling the 10/100/1000 Ethernet management interface.
The Console interface (CON) as well as the management interface (Port1) are located on the SCE8000-SCM-E located in slot# 1 of the Cisco SCE8000 GBE chassis (see Service Control Module (SCE8000-SCM-E)).
•
How to Set Up the Local Console
•
Initial Setup Parameters
•
Connecting the Management Interface
How to Set Up the Local Console
Even if you will be managing the Cisco SCE8000 GBE from a remote location, you must first connect the unit to a local console and configure the initial settings for the Cisco SCE8000 GBE to support remote management. When the initial connection is established, the setup utility will run automatically, prompting you to perform the initial system configuration.
This section provides instructions for setting up your local terminal at your workstation, to enable you to perform the initial system configuration of the Cisco SCE8000 GBE system using the setup utility.
Make sure that the terminal configuration is as follows:
•
9600 baud
•
8 data bits
•
No Parity
•
1 stop bits
•
No flow control
The above Cisco SCE8000 GBE port parameters are fixed and are not configurable.
Step 1
Plug the RS-232 serial cable provided with the Cisco SCE8000 GBE into the CON port on the front panel of the SCE8000-SCM-E. (See item #2 in Figure 5-1 below.)
Figure 5-1 Connecting the Local Console to the SCE8000-SCM-E CON Port
Make sure that you push on the RJ-45 connector (attached to the RS-232 serial cable) until you hear a "click", which indicates that the connector is fully inserted and secured in the receptacle. Gently pull on the plug to confirm whether the plug is locked into the socket.
Step 2
Connect the other end of the serial cable (with an attached DB-9 or DB-25 connector) to the VT100 compatible local (serial) terminal.
Step 3
Make sure the local terminal is configured as a VT-100 terminal, according to the fixed Cisco SCE8000 GBE CON port parameters.
Step 4
Make sure that the Cisco SCE8000 GBE is powered-on, and has been allowed to complete booting (this process may take several minutes).
Step 5
Press Enter several times until the Cisco logo appears on the local terminal.
Initial Setup Parameters
At this point there are several basic global parameters that must be correctly configured in order for the SCE platform to communicate properly with the outside world. The following is a very brief summary of the initial setup parameters and commands. For more information, refer to the Cisco SCE8000 GBE Software Configuration Guide.
•
IP address and subnet mask of the Cisco SCE8000 GBE platform itself. This is the IP address used by the GBE management interface.
•
IP address of the default gateway.
•
Hostname—The hostname is used to identify the SCE platform. It appears as part of the CLI prompt and is also returned as the value of the MIB-II object sysName.
–
The maximum length is 20 characters.
–
The default hostname is SCE8000 GBE.
•
Passwords for user, admin and root level access. These are authorization-level passwords, not individual passwords. These passwords may be encrypted.
Passwords must meet the following criteria:
–
Minimum length — 4 characters
–
Maximum length — 100 characters
–
Begin with an alpha character
–
May contain only printable characters
•
The default password for all levels is cisco.
•
System clock— Current date and time. The clock and the calendar must always be synchronized.
•
Time zone—The name or ID of the time zone along with the number of hours offset from UTC.
•
Domain name server—Default domain name, which is used to complete unqualified host names, as well as up to three domain name servers, which are used for DNS lookup.
You must also enable DNS lookup.
•
RDR formatter destination—The SCE platform generates Raw Data Records and sends them to the specified destinations (external collection systems) via the RDR formatter. You can configure up to eight RDR formatter destinations. Specify the IP address and port number for each destination.
Table 5-1 lists commands both for displaying the currently configured values and for configuring these parameters. It also lists the command mode for each configuration command. All show commands are executed from the User Exec command mode.
Table 5-1 Initial Setup Configuration
|
|
|
configuration command mode
|
Management IP address and subnet mask |
show interface GigabitEthernet 1/1 ip address |
ip address x.x.x.x subnet-mask |
GigabitEthernet Interface Configuration |
Default gateway |
show ip default-gateway |
ip default-gateway x.x.x.x |
Global Configuration |
Hostname |
show hostname |
hostname host-name |
Global Configuration |
Authorization level passwords |
N/A |
enable password level level [encryption-type] password |
Global Configuration |
Clock |
show clock show calendar |
calendar set hh:mm:ss day month year clock read-calendar OR clock set hh:mm:ss day month year clock update-calendar |
Privileged EXEC |
Time zone |
show timezone |
clock timezone zone-name offset-hours |
Global Configuration |
Domain name server |
show hosts |
ip domain-lookup ip domain-name domain-name ip name-server server-address1 [server-address2] [server-address3] |
Global Configuration |
RDR formatter destination |
show rdr-formatter destination |
rdr-formatter destination ip-address port port-number |
Global Configuration |
Connecting the Management Interface
The SCE8000-SCM-E is equipped with one active RJ-45 management port. This 10/100/1000 Ethernet interface provides access from a remote management console to the Cisco SCE8000 GBE via a LAN.
The procedures for cabling the management port and testing connectivity between the Cisco SCE8000 GBE and the remote management host are explained in the following sections.
•
How to Cable the Management Port
•
How to Verify Management Interface Connectivity
How to Cable the Management Port
The SCE8000-SCM-E has one 10/100/1000 Ethernet port that is used as the management port, located in slot# 1 of the Cisco SCE8000 GBE chassis, and labeled Port1.
Step 1
Plug the Ethernet cable provided (with attached RJ-45 connector) into Port 1on the front panel of the SCE8000-SCM-E. (See item #3 in Figure 5-2 below.)
Figure 5-2 Cabling the Management Port
Step 2
Connect the other end of the Ethernet cable into your management network.
Make sure that you push on the RJ-45 connector attached to the cable until you hear a click, which indicates that the connector is fully inserted and secured in the receptacle. Gently pull on the plug to confirm whether the plug is locked into the socket.
If the Link LED on the port does not light, try removing the cable and reinserting it firmly into the module socket. To disconnect the plug from the socket, press down on the raised portion on top of the plug, releasing the latch. You should hear an audible click indicating the latch has released. Carefully pull the plug out of the socket.
If the Link LED still does not light, verify that the cable is connected correctly to the appropriate network element on its second end.
How to Verify Management Interface Connectivity
If the Cisco SCE8000 GBE platform has been powered up, test now to verify that connectivity has been established between the Cisco SCE8000 GBE and the remote management host. If the Cisco SCE8000 GBE platform is not powered up, perform this step after starting the Cisco SCE8000 GBE platform.
Step 1
After you connect the cable to the GBE management port and to your network, check the Port1 LEDS.
There are two GBE LEDs — Link/Active, and 10/100/1000 (refer to Service Control Module (SCE8000-SCM-E)).
At this point, check that the Link/Active LED is green.
The state of the 10/100/1000 LED will depend on the Ethernet network settings, as follows:
•
Off: 10 Mbps
•
Green: 100 Mbps
•
Orange: 1000 Mbps
Step 2
Test connectivity. From the host that you intend to use for remote management, ping to the Cisco SCE8000 GBE by typing ping and the Cisco SCE8000 GBE IP address, and pressing Enter (see the example, below).
Note
Note that only this step (Step 2), is performed from the remote management host (connected by LAN to Port1).
This verifies that an active connection exists between the specified station and the management port.
The ping command sends an echo request packet to an IP address and then awaits a reply. Ping output can help you evaluate path-to-host reliability, delays over the path, and whether the host can be reached or is functioning.
EXAMPLE:
The following example displays a typical ping response where the target IP address is 10.10.10.20.
C:\>ping 10.10.10.20
pinging 10.10.10.20 ...
PING 10.10.10.20: 56 data bytes
64 bytes from host (10.10.10.20): icmp_seq=0. time=0. ms
64 bytes from host (10.10.10.20): icmp_seq=1. time=0. ms
64 bytes from host (10.10.10.20): icmp_seq=2. time=0. ms
64 bytes from host (10.10.10.20): icmp_seq=3. time=0. ms
----10.10.10.20 PING Statistics----
4 packets transmitted, 4 packets received, 0% packet loss
round-trip (ms) min/avg/max = 0/0/0