THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Products Affected
Product |
Comments |
3GE-GBIC-SC(=) |
800-06376-01 rev. A through rev. H (inclusive) |
Problem Description
Some 3-port GE line card may experience Tx SOP SRAM parity errors.
Background
This problem has been isolated to a timing anomaly on the line card which is associated with a particular revision of memory component.
Problem Symptoms
Tx SOP SRAM parity errors, an example of which is shown below:
SLOT 14:00:01:43: %LCPOS-3-SOP: Tx SOP. (source=0x20, halt_minor0=0x1)
Workaround/Solution
As of line card part number 800-06376-02 rev. A0 (and later) the 3-port GE line card is no longer using the revision of memory which is associated with this problem. Line card part number 800-06376-01 (any revision) is subject to the problem described in this field notice.
The probability of a field failure is low. Cisco recommends a fix-on-fail strategy for this problem.
Service Logistics has known-good inventory at this time. The standard RMA process and delivery times are in effect.
How To Identify Hardware Levels
The 800-level part number can be seen by using the
show diag slot command.
How to Identify Memory Components
Not all products within the affected revision range listed in the
Products Affected section above are affected by this problem. For customers who wish to be more selective in identifying and replacing potentially defective line cards the following information is provided.
The yellow rectangle in the photo below identifies the location of the memory modules in question.

Memory modules having a "Z" in the location shown in the yellow rectangle in the photo below are associated with this problem. Memory modules having a different letter or different labeling are not associated with this problem. In the example shown in the photo below, the memory module has a letter "Y" and is therefore not associated with this problem.

Revision History
Revision |
Date |
Comment |
1.5 |
03-MAR-2006 |
Removed Umpire Form |
1.4 |
26-MAR-2002 |
Maintenance Update |
1.3 |
02-NOV-2001 |
Maintenance Update |
1.2 |
03-OCT-2001 |
Maintenance Update |
1.1 |
02-AUG-2001 |
Maintenance Update |
1.0 |
18-JUL-2001 |
Initial Public Release |
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.