Guest

Cisco 10000 Series Routers

Cisco 10000 Series Channelized OC-12-STM-4 Line Card

Table Of Contents

Data Sheet

Key Features and Benefits

Hardware and Software Features

Channelization Features

Encapsulation

DS-1 Features

E1 Features

DS-3 Features

SONET and SDH Features

Other

Features Not Supported

Physical Specifications

Environmental Specifications

Product Regulatory Compliance
Environmental Conditions

Product Regulatory Approvals

Laser Safety

Electromagnetic Emissions Certification

Immunity

Network Equipment Building Systems

LEDs

Connector

Network Management

Power Budget

Optical Power Budget

Hardware Requirements

Software Requirements

Ordering Information


Data Sheet


Cisco 10000 Series Channelized

OC-12/STM-4 Line Card

The Cisco 10000 Series Channelized OC-12/STM-4 line card provides service providers with a high density DS0 aggregation solution.

Figure 1

Cisco 10000 Series Channelized OC-12/STM-4 Line Card

Designed for telcos and service providers (SPs), this line card supports one OC-12/STM-4 port with maximum DS3/DS1/DS0/64K flexibility in both a SONET and SDH environment.

Cisco 10000 Series channelized line cards integrate the channel service unit/data service unit (CSU/DSU) function on a per-port basis.

Key Features and Benefits

Designed for concentrating IP access over telco time-division multiplexing (TDM) networks, the Cisco 10000 Series channelized OC-12/STM-4 line card has the following key features and benefits.

Provides industry-leading density per rack, enabling service providers to scale networks cost-effectively.

Supports any combination of DS-0/64 kbps, fractional T-1/E-1, and DS-3 for maximum flexibility.

Supports service-transparent online insertion and removal (OIR), allowing line cards to be removed without impacting traffic.

Supports SONET automatic protection switching (APS) and SDH Multiplex Section Protection (MSP), valuable tools for supporting network resiliency, fault tolerance, and increased overall network availability. APS and MSP provide very fast Layer 1 switch over mechanism to support 1:1 redundant transmission circuits. They allow rapid switchover from one fiber connection to another in the event of a fiber cut, module failure, signal failure, or signal degradation. The result is increased network resiliency, minimal loss of data, and reduction in time-consuming data reroutes.

Hardware and Software Features

Single-port channelized OC-12/STM-4 occupies a single slot without any slot dependency

SC duplex connector, single-mode, intermediate-reach optics at 1330nm

IP supported

Online Insertion and Removal (OIR)

1:1 SONET Automatic Protection Switching (APS) and SDH Multiplex Section Protection (MSP)

Channelization Features

NxDS0 (Each DS1 and E1 may be further channelized into NxDS0 channels)

Channelization to DS0 (56K or 64K), including multiple channel groupings per DS1 and fractional DS1

DS1 clearchannel and fractional; Framed

E1 clearchannel and fractional; Framed and unframed

J1 support

Unchannelized and channelized DS3 (28xDS1)

DS3 Subrate & Scrambling; Interoperable with Kentrox, Digital Link, Larscom, Verilink and Adtran.

Supports up to 768 channels per card with any mixture of DS3, nxDS1, or nxDS0 with the following restrictions:

192 channels per STS-3/STM-1

Total number of channels does not exceed chassis scaling limits

Channelization to DS1 (SONET)

Support for SONET Virtual Tributary 1.5 (VT1.5) mapping: STS-12 <-> STS-1 <-> VT1.5 <-> DS-1

Support for asynchronous DS3 channelized down to DS-1 (M13 and C-bit framing) mapped into: STS-12 <-> STS-1 <-> DS-3 <-> DS-1

Channelization to DS1 (SDH)

STM-4 <-> AU-4 <-> TUG-3 <-> TUG-2 <-> TU-12 <-> DS-1

Channelization to E1(SONET)

Support for SDH Virtual Tributary 2 (VT2) mapping: STS-12 <-> STS-1 <-> VT2 <-> E-1

Channelization to E1(SDH)

Support for ITU-T G.707 (SDH CEPT/ETSI) Virtual Container 12 (VC-12) mapping: STM-4 <-> AU-4 <-> TUG-3 <-> TUG-2 <-> TU-12 <-> VC-12 <-> E-1

Channelization to J1

Support for ITU-T G.707 (SDH-ANSI) Virtual Container 11 (VC-11) mapping: STM-4 <-> AU-3 <-> TUG-2 <-> TU-11 <-> VC-11 <-> J1

Channelization to DS3 (SONET)

STS-12 <-> STS-1 <-> DS-3

Channelization to DS3 (SDH)

STM-4 <-> AU-3 <-> DS-3

Encapsulation

Frame Relay

Point-to-Point Protocol (PPP)

Cisco HDLC (support for shared flags, configurable IDLE pattern, and 16- or 32-bit cyclic redundancy check (CRC))

DS-1 Features

Superframe (SF) and Extended Superframe (ESF) support

Internal or line-derived (loop) clocking, independently selectable on each T-1 tributary

Error and alarm detection: CRC errors, framing errors, loss of frame (red), AIS (blue), remote alarm indication (yellow)

Alarm reporting-24-hour history maintained, 15-minute intervals on all errors

BERT at DS-1 level

Loopback capabilities: local, network line and network payload, remote network line and remote network payload at the T-1 level

ANSI T1.403 facility data link (FDL) on ESF mode DS1s and ATT 54016 FDL mode, responses only

Local and remote performance monitoring

Response to embedded remote loopback commands - BOC (bit oriented commands)

Detect and insert embedded remote loopback commands - BOC (bit oriented commands)

AIS

RDI

Loss of signal and loss of frame (near end and far end)

Loss of multiframe (LOMF)

Local and network line loopback

E1 Features

Framing: CRC-4 and no-CRC-4 conformance with ITU-T G.704

Internal or line-derived (loop) clocking, independently selectable on each E-1 tributary

Error and alarm detection: CRC errors, framing errors, loss of frame, AIS, remote alarm indication

Performance monitoring: 24-hour history retained; 15-minute intervals on all errors

BERT at E-1 level

Line and payload loopback capabilities-local and network line, and network payload at the E-1 level

DS-3 Features

Channelized, clearchannel or subrate

C-bit parity or M23 framing

FEAC channel support

* BERT at DS-3 level

Internal or line-derived (loop) clocking

Error and alarm detection: CRC errors, framing errors, loss of frame (red), AIS (blue), remote alarm indication (yellow)

Alarm reporting-24-hour history maintained, 15-minute intervals on all errors

Loopback capabilities: local, network line and network payload, remote network line and remote network payload

Local and remote performance monitoring

Response to embedded remote loopback commands - BOC (bit oriented commands)

Detect and insert embedded remote loopback commands - BOC (bit oriented commands)

AIS

RDI

Loss of signal and loss of frame (near end and far end)

Loss of multiframe (LOMF)

Local and network line loopback

SONET and SDH Features

Compliance with G.707, G.783, G.784, G.957, G.958, GR-253, as applicable

Synchronization Local (internal) or loop timed (recovered from network)

Local (diagnostic) and line (network) loopback

Alarm processing-Receive and transmit alarm processing. See Table 1 for supported alarm and signal events.

Statistics-Performance and error counts

TX path trace

RX path trace

Payload scrambling

Internal or line (as recovered from the network) clocking modes

Local (diagnostic) and network (line) loopback modes

SONET APS and SDH MSP, 1+1 unidirectional

Detect and alarm

AIS

RDI

Remote failure indicator

Loss of signal and loss of frame

Loss of pointer

Table 1  

Supported SONET/SDH Alarm and Signal Events Alarm/Signa
 
SONET Description
SDH Description
B1-TCA

B1 BER Threshold Crossing Alarm

B1 BER Threshold Crossing Alarm

B2-TCA

B2 BER Threshold Crossing Alarm

B2 BER Threshold Crossing Alarm

B3-TCA

B3 BER Threshold Crossing Alarm

B3 BER Threshold Crossing Alarm

LAIS

Line Alarm Indication Signal (AIS-L)

Multiplexer Section Alarm Indication Signal (MS-AIS)

LOM

Loss of Multiframe VT (LOM-V)

Loss of Multiframe (LOM)

LRDI

Line Remote Defect Indication (RDI-L)

Multiplexer Section Remote Defect Indication (MS-RDI)

PAIS

Path Alarm Indication Signal, or Alarm Indication Signal-Path (AIS-P)

Administrative Unit Alarm Indication Signal (AU-AIS)

PLM

Path Payload Label Mismatch, or Payload Label Mismatch-Path (PLM-P)

High Order Path Payload Label Mismatch (HP-PLM)

PLOP

Path Loss of Pointer, or Loss of Pointer-Path (LOP-P)

Administrative Unit Loss of Pointer (AU-LOP)

PRDI

Path Remote Defect Indication, or Remote Defect Indication-Path (RDI-P)

High Order Path Remote Defect Indication (HP-RDI)

PUNEQ

Path Unequipped (UNEQ-P)

High Order Path Unequipped (HP-UNEQ)

SD-BER

Line BIP BER in excess of the Signal Degrade (SD) threshold

Multiplexer Section BIP BER in excess of the Signal Degrade (SD) threshold

SF-BER

Line BIP BER in excess of the Signal Fail (SF) threshold

Multiplexer Section BIP BER in excess of the Signal Fail (SF) threshold

SLOF

Section Loss of Frame (LOF)

Regenerator Section Loss of Frame (LOF)

SLOS

Section Loss of Signal (LOS)

Regenerator Section Loss of Signal (LOS)


Other

Bit error rate testing (BERT)

Loopback capabilities: local and network at the OC-12/STM-4 level

Dynamic Provisioning on each physical port.

Scrambling and subrate can be independently or simultaneously enabled in each DSU mode.

Features Not Supported

OC-12c, STM-4c, OC-3c, STM-1c

Unframed DS-3 (HSSI)

DS-2 loopbacks, alarms, performance monitoring, or Management Information Base (MIB) support

DS-1 signaling

E-1 time slot 16 (TS16) signaling multiframe

E-1 Bit Oriented Protocol (BOP)

E-1 remote loopback

E-1 and DS-1 on the same port

Physical Specifications

Weight: 4.75 lb (2.16 kg)

Dimensions: 16.0 x 1.12 x 9.97 in. (40.64 x 2.83 x 25.32 cm) (H x W x D)

Environmental Specifications

Storage temperature: -38° to 150° F (-40° to 70° C)

Operating temperature, nominal: 41° to 104° F (5° to 40° C)

Operating temperature, short term: 23° to 131° F (-5° to 55° C)

Storage relative humidity: 5% to 95% relative humidity (RH)

Operating humidity, nominal: 5% to 85% RH

Operating humidity, short term: 5% to 90% RH

Operating altitude: -60 m to 4000 m

Product Regulatory Compliance
Environmental Conditions

Storage temperature: -38 to 150°F (-40 to 70°C)

Operating temperature, nominal: 41 to 104°F (5 to 40°C)

Operating temperature, short term: 23 to 131°F (-5 to 55°C)

Storage relative humidity: 5 to 95% relative humidity (RH)

Operating humidity, nominal: 5 to 85% RH

Operating humidity, short term: 5 to 90% RH

Operating altitude: -60 to 4000m

Product Regulatory Approvals

UL60950/CAN/CSA-C22.2 No. 60950-00, third edition, dated December 1, 2000, with no deviation considered to be less stringent than IEC 60950

EN60950 with Amendments 1-4, for CE Marking to the LVD directive

IEC 60950 third edition with Amendments 1-4, including all national/group deviations

AS/NZS 60950:2000

AS/NZS 3260-1993 with Amendments 1-4

ACA TS001-1997

Laser Safety

21 CRF 1040, Subchapter J

EN60825-1

EN60825-2

Electromagnetic Emissions Certification

AS/NZ 3548:1995 (including Amd I + II) Class B

EN55022:1998 Class B

CISPR 22:1997

EN55022:1994 (including Amd I+ II)

47 CFR Part 15:2000 (FCC) Class B

VCCI V-3/01.4 Class 2

CNS-13438:1997 Class B

GR1089:1997 (including Rev1: 1999)

Immunity

EN300386:2000—TNE EMC requirements; product family standard; high priority of service; central office and non-central office locations

EN50082-1:1992/1997

EN50082-2:1995—Generic Immunity Standard, Heavy Industrial

CISPR24:1997

EN55024:1998—Generic ITE Immunity Standard

EN61000-4-2:1995+AMD I + II—ESD, Level 4, 8-kV contact,15-kV air

IEC-1000-4-3:1995+AMD 1—Radiated Immunity, 10 V/m

IEC-1000-4-4:1995—Electrical Fast Transients, Level 4, 4 kV/B

IEC-1000-4-5:1995+AMD 1—DC Surge Class 3; AC surge Class 4

EN61000-4-6:1996+AMD 1—RF Conducted Immunity, 10V rms

EN61000-4-11:1995—Voltage Dips and Sags

ETS300 132-2:1996+corregendum, Dec. 1996

GR1089:1997 (including Rev1: 1999)

Network Equipment Building Systems

Level 3 compliant

Telcordia SR-3580 Criteria Levels, issued November 1995

GR1089-Core: Electromagnetic Compatibility & Electrical Safety, issued February 1999

GR63-Core: Physical Protection Requirements, issued April 2002

SBC equipment requirements: TP76200 MP and TP76400 MP

Verizon equipment requirements: SIT.NEBS.TE.NPI.2002.010

LEDs

Line card fail (Fail)—A single yellow LED that is set OFF when the board is working properly

Carrier detected (CA)—A green LED turned on when a carrier is detected on the port; it is the logical inverse of loss of signal (LOS)

Alarm (Alarm)—A yellow LED; during normal operation, this LED is on to indicate the presence of any alarm condition on any provisioned controller/interface at OC-12/STM-4, DS3, E1, or DS1 levels

Loopback active (LOOP)—A yellow loopback active LED used as an external indication that any portion of the data path is in a loopback state and not enabled for normal data traffic

Connector

SC duplex connector, single-mode, intermediate-reach optics

Network Management

Network Management via

Telnet (CLI)

Console port (CLI)

Simple Network Management Protocol (SNMP)

DS3 Management Information Base (MIB) (RFC 1407)

DS1 MIB (RFC 1406)]

MIB-II (RFC 1213)

SONET MIB (RFC 1595)

Power Budget

Component: Channelized OC-12/STM-4 line card

Unit Power: 85W max, 50W typ

Optical Power Budget

Power budget: 12db

Transmit power: -15 to -8 dBm

Receive power: -28 to -8 dBm

Typical maximum distance: 9.3 miles (15 km)

Hardware Requirements

Chassis—The 1-port CHOC12 line card is supported on all Cisco 10000 Series chassis

Performance routing engines (PREs)—The 4-port CHSTM-1 line card is supported on all PREs available on the Cisco 10000 Series

Software Requirements

Initial IOS Releases (PRE1): The 1-port CHOC12 line card is supported in 12.0(9)SL, 12.0(17)ST, 12.0(22)S, 12.2(8)BZ and later Cisco IOS® releases for SONET mode only. For both SONET and SDH mode, the 1-port CHOC12 line card is supported in 12.0(23)S and later Cisco IOS releases.

Initial IOS Releases (PRE2): For both SONET and SDH mode, the 1-port CHOC12 line card is supported in 12.2(15)BX and later Cisco IOS releases.

For the latest IOS release information, refer to:

http://www.cisco.com/pcgi-bin/front.x/Support/HWSWmatrix/hwswmatrix.cgi

Ordering Information

Product Number
Product Description
ESR-1COC12-SMI

One-port Channelized OC-12/STM-4 (STS-12) Line Card, Single Mode, Intermediate Reach

ESR-1COC12-SMI=

One-port Channelized OC-12/STM-4 (STS-12) Line Card, Single Mode, Intermediate Reach, SPARE


Service and Support

Cisco Systems offers a wide range of service and support options for its customers. More information on Cisco service and support programs and benefits can be found at:

http://www.cisco.com/en/US/support/