The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This chapter includes the following sections:
This guide contains information and procedures for installing Cisco UCS Rack Mount Servers for integration with Cisco UCS Manager release 2.1.
Cisco UCS C-Series Rack-Mount Servers are managed by the built-in standalone software, Cisco Integrated Management Controller (CIMC) . When a C-Series Rack-Mount Server is integrated with Cisco UCS Manager, the CIMC does not manage the server anymore. Instead it is managed with the Cisco UCS Manager software. You will manage the server using the Cisco UCS Manager GUI or Cisco UCS Manager CLI.
If your server is not factory new, make sure to reset the CIMC to factory default settings before integrating the server with Cisco UCS Manager.
You can integrate Cisco UCS C-Series Rack-Mount Servers with Cisco UCS Manager in either one of the following setup:
Cisco UCS Manager 2.1 provides two connectivity modes for Cisco UCS C-Series Rack-Mount Server management. The following are the two connectivity modes:
Dual-wire Management (Shared LOM): This management mode is supported in the Cisco UCS Manager releases earlier than 2.1. Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
Note | The LOM ports on Cisco UCS C-Series Rack-Mount Servers integrated with Cisco UCS Manager can not be used for data traffic. The LOM ports are disabled when the C-Series Rack-Mount Servers are in Cisco UCS Manager mode. |
The general prerequisites for Dual-wire integration with Cisco UCS Manager are built into the C-Series Rack-Mount Server CIMC release 1.4(6) or later. If you want to use the single-wire management you must have the following:
The following table lists theC-Series Rack-Mount Servers and supported management options:
Servers |
Single-wire Management |
Dual-wire Management |
---|---|---|
Cisco UCS C22 M3 Server |
Yes |
Yes |
Cisco UCS C24 M3 Server |
Yes |
Yes |
Cisco UCS C200 M2 Server |
No |
Yes |
Cisco UCS C210 M2 Server |
No |
Yes |
Cisco UCS C220 M3 Server |
Yes |
Yes |
Cisco UCS C240 M3 Server |
Yes |
Yes |
Cisco UCS C250 M2 Server |
No |
Yes |
Cisco UCS C260 M2 Server |
Yes |
Yes |
Cisco UCS C420 M3 Server |
Yes |
Yes |
Cisco UCS C460 M2 Server |
Yes |
Yes |
Based on your server model and CIMC version, you can use either one of these two integration options to connect the rack server withCisco UCS Manager 2.1.
Cisco UCS Manager runs within the fabric interconnect (FI). You can use any of the interfaces available with this management service to access, configure, administer, and monitor the network and server resources for all chassis connected to the fabric interconnect. For information about the Cisco UCS 6100 Series or 6200 Series fabric interconnects, see the documentation at the following links:
For information about the Cisco Nexus 2232 fabric extenders (FEXes) in the configuration, see the documentation at the following link:
You can connect the FEX to the FI in two ways. Cisco UCS Manager FI discovers the FEX based on the FEX/Chassis discovery mode. The FEX connection modes are:
Hard-Pinning mode: The server facing FEX ports are pinned to the connected uplink ports when the FEX is discovered. Cisco UCS Manager pins the server-facing ports to the uplink ports based on the number of acknowledged uplink ports. After the pinning, if you add a new uplink or delete an existing uplink, you must manually acknowledge the FEX to apply the changes.
Port-Channel mode: Port-Channel mode does not have pinning. A single port channel works as the uplink to all server-facing ports. And all uplink ports are members of this single port channel. If one of the uplink ports go down, the traffic is automatically distributed to another available uplink port.
Note | Port channel mode applies only to the 6200 series FIs. |
When port-channel uplinks from the FEX are connected only within a set of eight ports managed by a single chip, Cisco UCS Manager maximizes the number of VIFs used in service profiles deployed on the servers.
If uplink connections are distributed across ports managed by separate chips, the VIF count is decreased. For example, if you connect seven members of the port channel to ports 1–7, but the eighth member to port 9, this port channel can only support VIFs as though it had one member.
The Cisco UCS 6200 Series FI has six sets of eight contiguous ports. Each set of ports is managed by a single chip. For more information on FEX discovery policies and port-channel allocation, see the appropriate Cisco UCS Manager Configuration Guide.
The following table describes maximum configurable vNICs/vHBAs on a VIC adapter based on the number of FEX uplinks:
Acknowledged link between FEX and FI |
Maximum configurable vNICs/vHBA on a VIC adapter for the VIC adapter 1225, 1225T, 1227, 1227T |
Maximum configurable vNICs/vHBA on a VIC adapter for the adapter VIC P81E |
---|---|---|
1 |
Not supported |
Not supported |
2 |
3 |
4 |
4 |
9 |
10 |
8 |
21 |
22 |
Acknowledged link between FEX and FI |
Maximum configurable vNICs/vHBA on a VIC adapter for the VIC adapter 1225, 1225T, 1227, 1227T |
Maximum configurable vNICs/vHBA on a VIC adapter for the VIC adapter P81E |
---|---|---|
1 |
12 |
13 |
2 |
27 |
28 |
4 |
57 |
58 |
8 |
117 |
118 |
Only servers without expanders can have more than one RAID controllers in the Cisco UCS Manager integrated mode. The following servers are allowed to have more than one RAID controllers in the Cisco UCS Manager integrated mode:
Cisco UCS C24 M3 (UCSC-C24-M3S2)
Cisco UCS C420 M3 (UCSC-C420-M3)
Cisco UCS C240 M3 (UCSC-C240-M3S2)
Cisco UCS C240 M3 NEBS (UCSC-C240-SNEBS)
Cisco UCS C260 M2 (C260-BASE-2646)
Any server not on this list that has more than one RAID controllers installed fails discovery.