Cisco Data Center Interoperability Support Matrix
Fabric Services Interoperability Matrix

Table Of Contents

Fabric Services Interoperability Matrix

SANTap DVT Interoperability Support Matrix

HDS

IBM

HP

NetApp

EMC

Data Mobility Manager (DMM)

EMC

IBM

HP

HDS

NetApp

SUN

Storage Media Encryption (SME)

Symantec

EMC

HP

BakBone Software

IBM

FC-IP SAN Extension


Fabric Services Interoperability Matrix


This chapter lists Cisco fabric applications supported by the SSM module and tested by Cisco's Solution-Interoperability Engineering group (iLAB) to ensure seamless installation at the end-user data center.

SANTap DVT Interoperability Support Matrix

Data Mobility Manager (DMM)

Storage Media Encryption (SME)

FC-IP SAN Extension

SANTap DVT Interoperability Support Matrix

Table 3-1 SANTap DVT Interoperability Support Matrix

Storage Partner
Storage System Model
Page

HDS

TagmaStore Universal Storage Platform (USP), Adaptable Modular Storage, Lightning,

3

IBM

ESS 2105 model 800, DS 8100

4

DS4200 (FAStT 700), DS4500 (FAStT 900) HP

4

HP

HP MSA 1500, HP EVA XL4000 (HSV200, HSV201), 6000 (HSV200, HSV201), 8000 (2Gb or 4Gb)(HSV210

5

NetApp1

v3070c, FAS3050c, FAS940c (ONTAP 7.2.4)

6

EMC2

Symmetrix DMX1000, DMX3, CX500, CX700

7

1 For NetApp SANTap/ReplicatorX support matrix, go to: http://now.netapp.com/NOW/knowledge/docs/olio/guides/tdps/tdps_interoperability_guide.xls

2 For EMC SANTap/RecoverPoint support, use the EMC e-Lab Navigator web tool.


HDS

Table 3-2 TagmaStore Universal Storage Platform (USP), Adaptable Modular Storage, Lightning

Operating System
Host Bus Adapter
Multipath Support
NX-OS/SSI1
Type
Version

Windows 2003

Enterprise

Edition SP2/R2

Emulex: LPe11000, LP11000, LP10000

Qlogic: QLA2340, QLE2460

HDLM

SSM, MSM 18/4,

MDS 9222i,

3.0(2a)/3.0.2j

3.1(2b)/3.1(2b)

3.1(3a)//3.1(3)

2 3.2(2c) /3.2(3s)

3.3(2)/3.2(3s)

4.1(1b)/4.1(1j)

4.1(1c)/4.1(1j)

4.1(3a) /4.1(3i)

Netware

6.5 SP5

QLogic: QLA2340

bundled

HPUX

11i, 11iv2

HP: A6795A

HDLM

AIX

5.2, 5.3

IBM: 5715, 6239

VMWare

ESX 3.0.1

QLogic: QLA2340

bundled

Solaris

9

Emulex: LP10000, LP11000, LPe11000

HDLM

QLogic: QLA2340

HDLM

Linux

RedHatAS 4.0 UP4

Emulex: LPe11000, LP11000, LP10000

HDLM

1 Refer to the following link for SAN-OS Release Compatibility Matrix for Storage Service Module: http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/ssi/compatibility/matrix/SSImtx.html

2 This combination is supported on SANTap fabric service only.


IBM

Table 3-3 ESS 2105 model 800, DS 8100

Operating System
Host Bus Adapter
Multipath Support
NX-OS/SSI1
Type
Version

Windows 2003

Enterprise SP1

Emulex: LP11002

SDD

SSM, MSM 18/4, MDS9222i

3.0(2a)/3.0.2j

3.1(2b)/3.1(2b)

3.1(3a)//3.1(3)

2 3.2(2c) /3.2(3s)

3.3(2)/3.2(3s)

4.1(1b)/4.1(1j)

4.1(1c)/4.1(1j)

4.1(3a) /4.1(3i)

Solaris

10

QLogic: QLA2462

AIX3

5.3

IBM: FC5716

Linux RedHat

4.0

QLogic: QLA2462

1 Refer to the following link for MDS-NXOS Release Compatibility Matrix for Storage Service Interface: http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/4_1/ssi/matrix/SSImtx.html

2 This combination is supported on SANTap fabric service only.

3 SDD support for the DS8000 storage array family is in SSI 3.2(2b) version and higher.


Table 3-4 DS4200 (FAStT 700), DS4500 (FAStT 900) HP

Operating System
Host Bus Adapter
Multipath Support
NX-OS/SSI
Type
Version

Windows 2000

Advanced Server SP4

QLogic: QLA2462

RDAC1

SSM, MSM 18/4

MDS 9222i

3.0(2a)/3.0.2j

3.1(2b)/3.1(2b)

3.1(3a)//3.1(3)

2 3.2(2c) /3.2(3s)

3.3(2)/3.2(3s)

4.1(1b)/4.1(1j)

4.1(1c)/4.1(1j)

4.1(3a) /4.1(3i)

AIX

5.3

IBM: FC5716

Solaris

10

Emulex: LP11002

MPXIO

1 For AIX, RDAC is supported on SSI image 3.2(2b) and higher

2 This combination is supported on SANTap fabric service only.


HP

Table 3-5 HP MSA 1500, HP EVA XL4000 (HSV200, HSV201), 6000 (HSV200, HSV201), 8000 (2Gb or 4Gb)(HSV210

Operating System
Host Bus Adapter
Multipath Support
NX-OS/SSIc1
Type
Version

Windows 2000

Advanced Server SP4 (IA32)

QLogic: QLA2342

MPIO-DSM

SSM, MSM 18/4, MDS9222i

3.0(2a)/3.0.2j

3.1(2b)/3.1(2b)

3.1(3a)//3.1(3)

2 3.2(2c) /3.2(3s)

3.3(2)/3.2(3s)

4.1(1b)/4.1(1j)

4.1(1c)/4.1(1j)

4.1(3a) /4.1(3i)

Windows 2003

Enterprise

Edition SP1 (IA32, IA64, x64)

HP: QMH2462 (C-Class Mezzanine)

Qlogic: QLE2462, QLA2342

Emulex: LPe1105, LP11002-M4, LP1050DC.

HPUX

11.23, 11.11

HP: AB378A, A6826A

SecurePath

PVlink

Linux RedHat

4.0 (IA32)

Emulex: LPe1105 (C-Class Mezzanine)

Multipulse

4.0 (IA64)

QLogic: QLA2460

Qlogic-MPIO

1 Refer to the following link for MDS NX-OS Release Compatibility Matrix for Storage Service Interface: http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/sw/4_1/ssi/matrix/SSImtx.html

2 This combination is supported on SANTap fabric service only.


NetApp

Table 3-6 v3070c, FAS3050c, FAS940c (ONTAP 7.2.4)

Operating System
Host Bus Adapter
Multipath Support
NX-OS/SSI1
Type
Version

Windows 2000

Advanced Server SP4 (IA32)

Emulex: LP11000

MPIO-DSM

SSM, MSM 18/4, MDS9222i

3.0(2a)/3.0.2j

3.1(2b)/3.1(2b)

3.1(3a)//3.1(3)

2 3.2(2c) /3.2(3s)

3.3(2)/3.2(3s)

4.1(1b)/4.1(1j)

4.1(1c)/4.1(1j)

4.1(3a) /4.1(3i)

Windows 2003

Enterprise

Edition SP2/R2

QLogic: QLA2342

Emulex: LP11002

IA64

QLogic: Mezzanine QMH2462

HPUX

11.23

HP: A6795A

PVlink

AIX

5.3

Emulex: LP10000

MPIO-DSM

Solaris

10 U1

Emulex: LP11000

MPXIO

10 U3

QLogic: QLA2462

Linux RedHat

4.0 U4

Emulex: LPe11000

QLogic: QLA2460, Mezzanine QMH2462

Device Mapper

1 Refer to the following link for SAN-OS Release Compatibility Matrix for Storage Service Module: http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/ssi/compatibility/matrix/SSImtx.html

2 This combination is supported on SANTap fabric service only.


EMC

Table 3-7 Symmetrix DMX1000, DMX3, CX500, CX700

Operating System
Host Bus Adapter
Multipath Support
NX-OS/ SSI 1
Type
Version

Windows 2003

Enterprise

Edition

Emulex: LP9002DC, 10000, LP1105 (IBM Blade Center), LP9802DC, LP11000

QLogic: QMC2462 (Mezzanine card)

Power Path

SSM, MSM 18/4, MDS9222i

3.0(2a)/3.0.2j

3.1(2b)/3.1(2b)

3.1(3a)//3.1(3)

2 3.2(2c) /3.2(3s)

3.3(2)/3.2(3s)

4.1(1b)/4.1(1j)

4.1(1c)/4.1(1j)

4.1(3a) /4.1(3i)

AIX

5.1, 5.2, 5.3

IBM: 6239, 6228

HPUX

11iv2 (PA-RISC, IA-64)

HP: A6826A, A6795A

Linux RedHat

4.0 AS

QLogic: QLA234, Mezzanine card

Emulex: LP1105 (Mezzanine card)2

Solaris

8, 9, 10

Emulex: LP10000, LP10000DC

QLogic: QLA2342

Sun: X6768A

1 Refer to the following link for SAN-OS Release Compatibility Matrix for Storage Service Module: http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/ssi/compatibility/matrix/SSImtx.html

2 This combination is supported on SANTap fabric service only.


Data Mobility Manager (DMM)

Table 3-8 Data Mobility Manager1

Software Partner
Storage Array
Page

EMC

Transferring data from Existing CLARiiON 600 to New CLARiiON 700

10

Transferring data from Existing CLARiiON 600 to New DMX 3000

10

Transferring data from Existing Symmetrix-5 to New DMX 3000

11

Transferring Data from Existing Symmetrix 8430 to new HDS USPV

11

Transferring Data from Existing DMX-3 to new CLARiiON 600

11

Transferring Data from Existing DMX-3 to new CLARiiON 600, then from this CLARiiON 600 back to DMX-3

12

Under VCS control, transferring Data from Existing DMX-3 to new DMX-3

12

Under HACMP control, transferring Data from Existing DMX-3 to new DMX-3

12

Under MSCS control, transferring Data from Existing DMX-3 to new DMX-3

12

Transferring Data from Existing DMX-3 to new DMX-3

13

Transferring Data from Existing DMX-3 to IBM SVC

13

Under Sun Cluster control, transferring Data from Existing DMX-3 to new DMX-3

13

IBM

Transferring data from Existing FAStT to New DS4500

14

Transferring data from Existing ESS 2105 model 800 to New DS8000

14

Transferring data from Existing ESS 2105 model 800 to New DS8000

15

Transferring data from Existing HP EVA 4000 to New IBM DS8100

15

Transferring data from Existing HP XP12000 to New IBM DS8100

15

Under VMware ESX environment, transferring data from Existing FAStT900 to New IBM DS4500

16

Under MSCS, transferring data from Existing HDS 9585v to New IBM DS8100

16

HP

Transferring data from Existing EVA 5000 to New EVA 4000/ 8000

17

Transferring data from Existing EVA 5000 to New XP12000

17

Transferring data from Existing EVA 5000 to New XP12000

17

Under Oracle RAC environment, transferring data from Existing HP EVA 4000 to New HP EVA 4000

18

Transferring data from Existing XP1024 to New XP12000

18

HDS

Transferring data from Existing HDS9585 to New HDS9970v

19

Transferring data from Existing HDS9585 to New TagmaStore

19

Transferring data from Existing HDS9000 to New TagmaStore

20

Transferring data from Existing HDS9200 to New HDS USPV

20

NetApp

Transferring data from Existing FAS940C to New FAS940C

21

SUN

Transferring data from Existing StorageTek 9985V to New Storage Tek 9990V

22

Transferring data from Existing Storage Tek 9900V to New Storage Tek 9990V

22

1 The following matrices includes configurations tested and certified by Cisco Quality Assurance labs. For more details on the listed configs including the SAN-OS and SSI versions, send an inquiry request to "mds-rpq@cisco.com". For configurations other than listed below, please send an RPQ request to "mds-rpq@cisco.com". Method 3 configuration is not supported on MDS9222i.


EMC

Table 3-9 Transferring data from Existing CLARiiON 600 to New CLARiiON 700

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003 R2

SP1

QLogic: QLE2462

PowerPath

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

PowerPath

LVM

Emulex: LPe11002

AS 4.0

QLogic: QLE2462

Device Mapper

LVM2

Emulex: LPe11002-M4

PowerPath

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

PowerPath

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

PowerPath

AIX

5.3

IBM: 03N5014

PowerPath

LVM


Table 3-10 Transferring data from Existing CLARiiON 600 to New DMX 3000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003 R2

SP1, SP2

QLogic: QLE2462

PowerPath

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

Emulex: LPe11002-M4

PowerPath

LVM

AS 4.0

QLogic: QLE2462

PowerPath

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

PowerPath

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

PowerPath

AIX

5.3

IBM: 03N5014

PowerPath

LVM


Table 3-11 Transferring data from Existing Symmetrix-5 to New DMX 3000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

PowerPath

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

PowerPath

LVM

Emulex: LPe11002-M4

AS 4.0

QLogic: QLE2462

PowerPath

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

PowerPath

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

PowerPath

AIX

5.3

IBM: 03N5014

PowerPath

LVM


Table 3-12 Transferring Data from Existing Symmetrix 8430 to new HDS USPV

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003 R2

SP2

QLogic: QLE2462

PowerPath

Windows Native

SSM

MDS 9222i

MSM 18/4

 

Linux RedHat

AS 4.0

Emulex: LPe11002-M4

PowerPath

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

AIX

5.3

IBM: 03N5014

PowerPath

LVM


Table 3-13 Transferring Data from Existing DMX-3 to new CLARiiON 600

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Solaris

8

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

PowerPath

VxVm

SSM

MDS 9222i

MSM 18/4


Table 3-14 Transferring Data from Existing DMX-3 to new CLARiiON 600, then from this CLARiiON 600 back to DMX-3

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003 R2

SP2

QLogic: QLE2462

PowerPath

Windows Native

SSM

MDS 9222i

MSM 18/4

AIX

5.3

IBM: 03N5014

MPIO

LVM


Table 3-15 Under VCS control, transferring Data from Existing DMX-3 to new DMX-31

Operating Systems
OS Version
VCS version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Solaris

10

5.0 w/IO fencing

Emulex: LPE11002-M4

Veritas DMP

VxVm

SSM

MDS 9222i

MSM 18/4

5.0 w/out IO fencing

4.1 w/ IO fencing

PowerPath 4.5.1

4.1 w/out IO fencing

1 For VCS, the following cutover procedure need to be followed:

1 a. When ready for cutover first stop all application traffic from all cluster nodes
1 b. Wait for migration to reach 100% (This step can be eliminated once the issue is fixed in a future release)
1 c. Shutdown VCS
1 d. Click "Finish" in DMM GUI

1 e. Once complete change zoning and cutover to NS (Follow the general procedure from this step)


Table 3-16 Under HACMP control, transferring Data from Existing DMX-3 to new DMX-3

Operating Systems
OS Version
HACMP version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H//W

AIX

5.3

5.4

IBM: 03N5014

Power Path 5.1

LVM

SSM

MDS 9222i

MSM 18/4


Table 3-17 Under MSCS control, transferring Data from Existing DMX-3 to new DMX-3

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H//W

Windows2003 R2

SP2

Emulex: LPE11002-M4

PowerPath 5.1

native

SSM1

MDS 9222i

MSM 18/4

1 DMM Method 3 and DMM Storage Type Job are not supported with MSCS.


Table 3-18 Transferring Data from Existing DMX-3 to new DMX-3

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H//W

Windows2000 AS

SP4

Emulex: LPE11002-M4

PowerPath 4.5.2

native

SSM

MDS 9222i

MSM 18/4

Windows 2003 R2

SP2 (x64)

PowerPath 5.1.1

native


Table 3-19 Transferring Data from Existing DMX-3 to IBM SVC1

Operating Systems
OS Version
Host Bus Adapter
SVC Version
Multipath App.
Volume Manager
Switch H//W

AIX

5.3

IBM: 03N5014

4.1.0.566

MPIO

LVM

SSM

MDS 9222i

MSM 18/4


Table 3-20 Under Sun Cluster control, transferring Data from Existing DMX-3 to new DMX-3

Operating Systems
OS Version
Sun Cluster Ver
Host Bus Adapter
Multipath App.
Volume Manager
Switch H//W

Solaris

10

3.2

Emulex: LPe11002-M4

MPXIO

SVM

SSM

MDS 9222i

MSM 18/4


Operating Systems
OS Version
VCS version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Solaris

10

5.0 w/IO fencing

Emulex: LPE11002-M4

Veritas DMP

VxVm

SSM

MDS 9222i

MSM 18/4

5.0 w/out IO fencing


IBM

Table 3-21 Transferring data from Existing FAStT to New DS4500

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

RDAC

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLA2342

RDAC

LVM

AS 4.0

QLogic: QLA2342

Device Mapper

LVM2

Emulex: LPe11002-M4

RDAC

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

RDAC

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

RDAC

AIX

5.3

IBM: 03N5014

RDAC

LVM


Table 3-22 Transferring data from Existing ESS 2105 model 800 to New DS8000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLA2342

SDD

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

Emulex: LPe11002-M4

SDD

LVM

AS 4.0

Emulex: LPe11002-M4

Device Mapper

LVM2

SDD

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

SDD

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

SDD

AIX

5.3

IBM: 03N5014

SDD

LVM


Table 3-23 Transferring data from Existing DS4500 to New DS8000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLA2342

RADAC, SDD

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLA2342

SDD

LVM

AS 4.0

Emulex: LPe11002-M4

SDD

LVM2

QLogic: QLA2342

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

RDAC, SDD

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

RDAC, SDD

AIX

5.3

IBM: 03N5014

RDAC, SDD

LVM


Table 3-24 Transferring data from Existing HP EVA 4000 to New IBM DS8100

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP2

QLogic: QLE2462

MPIO

Windows Native

SSM

MDS 9222i

MSM 18/4

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

AIX

5.3

IBM: 03N5014

HP MPIO / AIX MPIO

LVM


Table 3-25 Transferring data from Existing HP XP12000 to New IBM DS8100

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP2

QLogic: QLE2462

MPIO

Windows Native

SSM

MDS 9222i

MSM 18/4

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm


Table 3-26 Under VMware ESX environment, transferring data from Existing FAStT900 to New IBM DS4500

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

VMware ESX

ESX Server 3.0.1

Linux RH 4.0

QLogic: QLA2432

VMware Native

VMware Native

SSM

MDS 9222i

MSM 18/4

VMware ESX

ESX server 3.0.1

Windows 2003 Server

QLogic: QLA2432

VMware Native

VMware Native


Table 3-27 Under MSCS, transferring data from Existing HDS 9585v to New IBM DS8100

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP2

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4


HP

Table 3-28 Transferring data from Existing EVA 5000 to New EVA 4000/ 8000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

SecurePath

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

Emulex: LPe11002-M4

SecurePath

LVM

AS 4.0

QLogic: QLE2462

QL Failover

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

MPXIO

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

SecurePath

AIX

5.3

IBM: 03N5014

SecurePath

LVM


Table 3-29 Transferring data from Existing EVA 5000 to New XP12000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

MPIO

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

QL Failover

LVM

AS 4.0

QLogic: QLE2462

QL Failover

LVM2

Emulex: LPe1102-M4

Multipulse

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

MPXIO

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

SecurePath

AIX

5.3

IBM: 03N5014

SecurePath

LVM


Table 3-30 Under Oracle RAC environment, transferring data from Existing HP EVA 4000 to New HP EVA 4000

Operating Systems
OS Version
Oracle RAC/ Clusterware
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Linux RedHat

AS 4.0

Oracle DB 11g R1

Oracle Clusterware

11gR1

Emulex:LPe11002-M4

Emulex Multipulse

HP Multipulse

LVM2

SSM

MDS 9222i

MSM 18/4


Table 3-31 Transferring data from Existing XP1024 to New XP12000

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

MPIO

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

QL Failover

LVM

AS 4.0

QLogic: QLE2462

QL Failover

LVM2

Emulex: LPe11002-M4

Multipulse

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

MPXIO

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

SecurePath

AIX

5.3

IBM: 03N5014

?

LVM


HDS

Table 3-32 Transferring data from Existing HDS9585 to New HDS9970v

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

LVM

AS 4.0

QLogic: QLE2462

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HDLM

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

HDLM

AIX

5.3

IBM: 03N5014

HDLM

LVM


Table 3-33 Transferring data from Existing HDS9585 to New TagmaStore

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

Emulex: LPe11002-M4

LVM

AS 4.0

QLogic: QL?2462

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HDLM

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

HDLM

AIX

5.3

IBM: 03N5014

HDLM

LVM


Table 3-34 Transferring data from Existing HDS9000 to New TagmaStore

Operating Systems

OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

LVM

AS 4.0

QLogic: QLE2462

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HDLM

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

HDLM

AIX

5.3

IBM: 03N5014

HDLM

LVM


Table 3-35 Transferring data from Existing HDS9200 to New HDS USPV

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4

Linux RedHat

AS 4.0

QLogic: QLE2462

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

AIX

5.3

IBM: 03N5014

HDLM

LVM


NetApp

Table 3-36 Transferring data from Existing FAS940C to New FAS940C

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

N/A

Windows Native

SSM

MDS 9222i

MSM 18/4

Linux RedHat

AS 3.0

QLogic: QLE2462

NA

LVM2


SUN

Table 3-37 Transferring data from Existing StorageTek 9985V to New Storage Tek 9990V

Operating Systems
OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

Emulex: LPe11002-M4

LVM

AS 4.0

QLogic: QL?2462

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HDLM

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

HDLM

AIX

5.3

IBM: 03N5014

HDLM

LVM


Table 3-38 Transferring data from Existing Storage Tek 9900V to New Storage Tek 9990V

Operating Systems

OS Version
Host Bus Adapter
Multipath App.
Volume Manager
Switch H/W

Windows 2003

SP1

QLogic: QLE2462

HDLM

Windows Native

SSM

MDS 9222i

MSM 18/4

Emulex: LPe11002-M4

Linux RedHat

AS 3.0

QLogic: QLE2462

LVM

AS 4.0

QLogic: QLE2462

LVM2

Emulex: LPe11002-M4

Device Mapper

LVM2

Solaris

10

Emulex: LPe11002-M4 (Leadville)

Veritas DMP

VxVm

HDLM

HPUX

11iv2

HP: AB378-60101

HP PVLinks

LVM

HDLM

AIX

5.3

IBM: 03N5014

HDLM

LVM


Storage Media Encryption (SME)

Table 3-39 Storage Media Encryption1

Software Partner
Data Center Backup Application
Page

Symantec

Veritas NetBackup

24

EMC

Legato Networker

26

HP

HP Data Protector

28

BakBone Software

NetVault

29

IBM

Tivoli Storage Manager (TSM)

30

1 The following matrices include configurations tested and certified by Cisco Quality Assurance Labs.For configurations other than listed below, please send an RPQ request to "mds-rpq@cisco.com".


Symantec

Table 3-40 Veritas NetBackup 

Operating Systems
NetBackup Version
Tape Library Model
Tape Drives & Emulated Libraries Supported
Switch H/W

Windows 20001 (SP4)

5.1

Sun/STK L180

STK 9840C, IBM LTO-2

SSN, MDS9222i

MSM-18/4

3.3(1c)

4.1(3a)

4.2(1a)

HP Standalone Tape Drive

MSL 6060

6.0

Sun/STK L180

HP LTO-2,

Sun/STK L700e

STK T10k, IBM LTO-3, IBM LTO-2, HP LTO-3

Sun/STK L8500

HP LTO-2, HP LTO-3,

IBM LTO-2, IBM LTO-3

EMC CDL 4400

ADIC i2k SDLT320

Sun/STK SL500 IBM LTO-3

Quantum ADIC Scalar i2000

IBM LTO-3

IBM Standalone Tape Drive

IBM 3592

Windows 2003 (SP1)

5.1

Sun/STK L180

IBM LTO-2, STK 9840C

Sun/STK L700e

STK T10k, HP LTO-3,

IBM LTO-3

HP Stainable Tape Drive

HP MSL 6060

6.0

Sun/STK L180

HP LTO-2

Sun/STK L700e

STK T10k, HP LTO-3,

IBM LTO-2, IBM LTO-3

Sun/STK L8500

HP LTO-2, HP LTO-3,

IBM LTO-2,

Quantum ADIC Scalar i2000

IBM LTO-3

EMC CDL 4400

ADIC i2k SDLT320,

Sun/STK SL500 IBM LTO-3

IBM Standalone Tape Drive

IBM 3592

Solaris 8

5.1

Sun/STK L180

HP LTO-2, STK 9840C, IBM LTO-2

Sun/STK L700e

HP LTO-3, STK T10k

IBM LTO-3

6.0

Sun/STK L8500

HP LTO-2, HP LTO-3,

IBM LTO-2, IBM LTO-3, SDLT 600

Solaris 10

5.1

Sun/STK L180

HP LTO2, STK 9840C,

SSN, MDS9222i

MSM-18/2

3.3(1c)

4.1(3a)

4.2(1a)

6.0

Quantum ADIC Scalar i2000

IBM LTO-3

Sun/STK L700e

STK T10k, IBM LTO-2, IBM LTO-3, STK 9940B

Sun/STK SL500

HP LTO-4

Sun/STK L700

IBM LTO-4

Sun/STK L8500

HP LTO-3, HP LTO-2,

STK T10k, IBM LTO-2, IBM LTO-3,

SDLT 600

EMC CDL 4400

ADIC i2k SDLT 320

Sun/STK SL500 IBM LTO-3

IBM 3584

IBM LTO-2

IBM Stand Alone Tape

IBM 3592

SpectraLogic T120

IBM LTO-2, IBM LTO-3

6.5

Sun/STK L700

IBM LTO-4

AIX 5.3

6.0

Sun/STK L700e

IBM LTO-2, IBM LTO-3, HP LTO-3, STK T10k

EMC CDL 4400

Sun/STK SL500 IBM LTO-3

1 Windows 2000 operating system is supported on SAN-OS 3.3(1c) code version only.


EMC

Table 3-41 Legato Networker 

Operating Systems
Networker Version
Tape Library Model
Tape Drives & Emulated Libraries Supported
Switch H/W

Windows 20001 (SP4)

7.2.1

Sun/STK L700e

HP LTO-3, IBM LTO-2, IBM LTO-3

SSN, MDS9222i

MSM-18/2

3.3(1c)

4.1(3a)

4.2(1a)

Quantum ADIC Scalar i2000

IBM LTO-3

EMC CDL 4400

ADIC i2k SDLT320

Sun/STK SL500 IBM LTO-3

7.3.2

Sun/STK L180

HP LTO-2, IBM LTO-2

Sun/STK L700e

STK T10k

Sun/STK L8500

IBM LTO-2, IBM LTO-3

IBM Standalone Tape Drive

IBM 3592, HP MSL 6060

Windows 2003 (SP1)

7.2.1

Sun/STK L700e

IBM LTO-2, IBM LTO-3, HP LTO-3

Quantum ADIC Scalar i2000

HP MSL 6060

EMC CDL 4400

ADIC i2k SDLT320

Sun/STK SL500 IBM LTO-3

7.3.2

Sun/STK L180

STK 9840C, HP LTO-2, IBM LTO-2

Sun/STK L700e

STK T10k, STK 9940B

Sun/STK L8500

IBM LTO-2, IBM LTO-3

IBM Standalone Tape Drive

IBM 3592, HP MSL 6060

7.4

Sun/STK SL500

HP LTO-4

Sun/STK L700

IBM LTO-4

Sun/STK L8500

HP LTO-2

Solaris 8

7.2.1

Sun/STK L700e

IBM LTO-3

7.3.2

Sun/STK L700

IBM LTO-3

Solaris 10

7.2.1

Sun/STK L700e

HP LTO-3, IBM LTO-2,

IBM LTO-3

7.3.2

Sun/STK L700e

STK T10k

Sun/STK L180

HP LTO2, STK 9840C,

IBM LTO-2

Quantum ADIC Scalar i2000

IBM LTO-3

Sun/STK L8500

IBM LTO-3, SDLT 600

EMC CDL 4400

ADIC i2k SDLT 320

Sun/STK SL500 IBM LTO-3

IBM Stand Alone Tape

IBM 3592

AIX 5.3

7.2.1

Sun/STK L700e

IBM LTO-2, IBM LTO-3, HP LTO-3

SSN, MDS9222i

MSM-18/2

3.3(1c)

4.1(3a)

4.2(1a)

7.3.2

Sun/STK L700e

STK T10k

EMC CDL 4400

Sun/STK SL500 IBM LTO-3

IBM Standalone Tape Drives

IBM 3592

HP-UX 11i (ia64)

7.3.2

Sun/STK L700

IBM LTO-3

1 Windows 2000 operating system is supported on SAN-OS 3.3(1c) code version only.


HP

Table 3-42 HP Data Protector

Operating Systems
Data Protector
Tape Library Model
Tape Drives & Emulated Libraries Supported
Switch H/W

Linux RedHat

(version 4.0)

Linux SUSE

(SLES 9.0)

6.0

ESL 322e

HP LTO-2

SSN, MDS9222i

MSM-18/2

3.3(1c)

4.1(3a)

4.2(1a)

MSL 2024

HP LTO-3

VLS 6105

HP LTO-2, HP LTO-3

ESL E-series

HP LTO-3

MSL 6030

Quantum SDLT 600

EML E-series

HP LTO-4

MSL 8096

HP LTO-4

Windows 2003

(Enterprise)

6.0

ESL 322e

HP LTO-2

MSL 2024

HP LTO-3

VLS 6105

HP LTO-2, HP LTO-3

ESL E-series

HP LTO-3

MSL 6030

Quantum SDLT 600

EML E-series

HP LTO-4

MSL 8096

HP LTO-4

HP-UX 11iv3

6.0

HP ESL 322e

HP LTO-2

5.5

HP ESL 322e

HP LTO-2, HP LTO-3

SUN/STK 8500

HP LTO-2, HP LTO-3

EMC CDL 4400

SL500 HP LTO-3


BakBone Software

Table 3-43 NetVault

Operating Systems
NetVault
Tape Library Model
Tape Drives & Emulated Libraries Supported
Switch H/W

Linux RHEL V4

8.0

Sun/STK L180

HP LTO-2, IBM LTO-2

SSN, MDS9222i

MSM-18/2

3.3(1c)

4.1(3a)

4.2(1a)

Stand Alone drive

HP LTO-4

8.2

Sun/STK L180

HP LTO-3, IBM LTO-3, HP LTO-4, IBM LTO-4

Linux RHEL V5

8.2

NetApp FAS Series

8.0 (NDMP)

Sun/STK L180

HP LTO-2, IBM LTO-2

8.2 (NDMP)

HP LTO-3, IBM LTO-3, HP LTO-4, IBM LTO-4

8.0 (NDMP)

Stand Alone drive

HP LTO-4

EMC CDL Series

8.2 (NDMP)

Sun/STK L180

IBM LTO-3, IBM LTO-4

Sun/STK SL500


IBM

Table 3-44 Tivoli Storage Manager (TSM)

Operating Systems
TSM Version
Tape Library Model
Tape Drives & Emulated Libraries Supported
Switch H/W

Windows 20001 (SP4)

5.4.0

IBM Stand-Alone Tape

IBM LTO-2, IBM TS1120

SSN, MDS9222i

MSM-18/2

3.3(1c)

4.1(3a)

4.2(1a)

Windows 2003 (SP2)

5.4.0

IBM Stand-Alone Tape

IBM LTO-2, IBM TS1120

Linux RH AS 4 U2 kernel 2.6.9.22

5.4.0

IBM Stand-Alone Tape

IBM LTO-2, IBM TS1120

AIX 5.3

5.4.0

SUN/STK 8500

HP LTO-2

SUN/STK SL500

HP LTO-3, IBM LTO-4, HP LTO-4

IBM Stand-Alone Tape

IBM TS1120, IBM LTO-2

EMC CDL SL500

IBM LTO-2, IBM LTO-4

SUN/STK L700

IBM LTO-2, IBM LTO-3, STK9840C, STKT10000A

SUN/STK L180

IBM LTO-2

IBM 3584

IBM LTO-2

Quantum ADIC Scalar i2000

IBM LTO-3

EMC CDL 4400

IBM LTO-3

EMC CDL 4400

SL500-IBM LTO-3

5.4.2

SUN/STK SL500

HP LTO-4

SUN/STK L700

IBM LTO-4

5.5.1

SpectraLogic T120

IBM LTO-2, LTO-3

1 Windows 2000 operating system is supported on SAN-OS 3.3(1c) code version only.


FC-IP SAN Extension

Table 3-45 SAN Extension InterOp Support Matrix

MDS Line Card Module
IPSec
FC-IP WA
Compression
FC-IP TA
     

H/W

S/W

 
       

Mode 1

Mode 2

Mode 3

 

9216i/14+2 to 9216i/14+2

Yes

Yes

Yes (LZS)

See note1

Yes (DEFLATE moderate comp)

Yes (DEFLATE high comp)

Yes

9216i/14+2 to 9222i/18+4

Yes

No

No

See note2

9222i/18+4 to 9222i/18+4

Yes

Yes

Yes (DEFLATE)

See note3

Yes

IPS(IPS-4/IPS-8) to IPS(IPS-4/IPS-8)

Yes

Yes

No

Yes (LZS)

Yes (DEFLATE moderate comp)

Yes (DEFLATE high comp)

Yes

IPS to 9216i/14+2 (See note4 )

Yes

Yes

See note5

Yes (DEFLATE moderate comp)

Yes (DEFLATE high comp)

Yes

IPS to 9222i/18+4 (See note4)

Yes

No

No

See note1

1 If Mode1 is configured on 9216i/14+2 HW (LZS) compression will be in effect

2 Veritas NetBackup and IBM TSM backup applications are supported only

3 On 9222i/18+4 mode1/mode2/mode3 configuration will automatically be converted to "auto" which means H/W (DEFLATE) compression will in effect

4 The IPS modules are not supported in Nx-OS 4.x and higher. However, replication between IPS module running SAN-OS 3.x code version to the 4.x supported modules is supported.

5 S/W LZS on IPS4/8 side and H/W LZS on 14+2 side


1 SVC back-end storage: IBM Shark and FASt900