Table Of Contents
Specifications and Compliance
Electrical Specifications
Physical and Environmental Specifications
Safety
Electromagnetic Compatibility
Specifications and Compliance
This chapter describes the HCA Expansion Card specifications and compliance certifications.
Electrical Specifications
Table 3-1 lists LVTTL signal levels.
Table 3-1 LVTTL Signal Levels
Parameter
|
Test Condition
|
Min
|
Nom
|
Max
|
Units
|
VOH
|
|
2.4
|
|
3.3
|
Volts
|
VOL
|
|
0.0
|
|
0.4
|
Volts
|
VIH
|
|
2.0
|
|
5.5
|
Volts
|
VIL
|
|
-0.5
|
|
0.8
|
Volts
|
IIH
|
|
|
|
4.0
|
mAmps
|
IIL
|
|
|
|
2.5
|
mAmps
|
Table 3-2 lists I2C signal levels.
Table 3-2 12C Signal Levels
Parameter
|
Test Condition
|
Min
|
Nom
|
Max
|
Units
|
VOH
|
|
2.4
|
|
3.3
|
Volts
|
VOL
|
|
0.0
|
|
0.4
|
Volts
|
VIH
|
|
2.0
|
|
5.5
|
Volts
|
VIL
|
|
-0.5
|
|
0.8
|
Volts
|
IIH
|
|
|
|
4.0
|
mAmps
|
IIL
|
|
|
|
2.5
|
mAmps
|
Table 3-3 lists InfiniBand signal levels.
Table 3-3 InfiniBand Signal Levels
Parameter
|
Test Condition
|
Min
|
Nom
|
Max
|
Units
|
TX diff. Peak to Peak
|
Vdd = 2.5V
|
0.9
|
|
1.6
|
Volts
|
RX diff. Input Peak to Peak
|
Vdd = 2.5V
|
0.2
|
|
2.2
|
Volts
|
Physical and Environmental Specifications
Table 3-4 lists temperature and cooling conditions.
Table 3-4 Temperature and Cooling
Condition
|
Range
|
Operating temperature
|
5 to 67 degrees Celsius, local ambient temperature
|
System Non-operating
|
-40 to 90 degrees Celsius
|
Operating altitude
|
0 to 10,000 ft
|
Non-operating altitude
|
0 to 50,000 ft
|
Table 3-5 lists temperature and cooling conditions.
Table 3-5 Humidity
Condition
|
Range
|
Operating Humidity
|
8% to 80% non-condensing
|
Operating Gradient
|
Maximum per 60 min: 10%
|
Non-Operating Humidity
|
5% to 80%, non-condensing
|
Safety
The HCA Expansion Card meets the following safety agency standards:
•
USA: UL 60950.
•
Canada: CAN60950
•
Europe: IEC60950, EN60950, EN60825-1 and EN60825-2
Electromagnetic Compatibility
The HCA Expansion Card meets the following EMC "Class A" standards, when installed in and operated within a closed chassis:
•
USA: CFR 47 Part 15, Subpart B
•
Canada: ICES-003 Issue 2
•
Europe: EN 61000-3-2 (Harmonics), EN 61000-3-3 (Flicker), EN 55022 1998, EN 55024 1994
•
Japan: VCCI-V3/97.04