Cisco 7600 Series Router MIB Specifications Guide
Monitoring Notifications

Table Of Contents

Monitoring Notifications

SNMP Notification Overview

Enabling Notifications

Cisco SNMP Notifications

Environmental or Functional Notifications

Flash Card Notifications

Interface Notifications

Cisco MPLS Notifications

Service Notifications

Routing Protocol Notifications

Chassis Notifications

RTT Monitor Notifications

Environmental Notifications

Redundancy Framework Notifications

CPU Usage Notifications


Monitoring Notifications


This chapter describes the Cisco 7600 Series Routernotifications supported by the MIB enhancements feature introduced in Cisco IOS Release 12.2(33)SRC. SNMP uses notifications to report events on a managed device. The notifications are traps or informs for different events. The router also supports other notifications not listed.

This chapter contains the following sections:

SNMP Notification Overview

Cisco SNMP Notifications

SNMP Notification Overview

An SNMP agent can notify the manager when important system events occur, such as the following:

An interface or card starts or stops running

Temperature thresholds are crossed

Authentication failures occur

When an agent detects an alarm condition, the agent:

Logs information about the time, type, and severity of the condition

Generates a notification message, which it then sends to a designated IP host

SNMP notifications are sent as either:

Traps—Unreliable messages, which do not require receipt acknowledgement from the SNMP manager.

Informs—Reliable messages, which are stored in memory until the SNMP manager issues a response. Informs use more system resources than traps.

To use SNMP notifications on your system, you must specify their recipients. These recipients indicate where Network Registrar notifications are directed. By default, all notifications are enabled, but no recipients are defined. Until you define the recipients, no notifications are sent.

Many commands use the word traps in the command syntax. Unless there is an option in the command to select either traps or informs, the keyword traps refers to either traps, informs, or both. Use the snmp-server host command to specify whether to send SNMP notifications as traps or informs. The types of traps can be specified in both commands.


Note Most notification types are disabled by default. However, some notification types cannot be controlled with the snmp command. For example, some notification types are always enabled and other types are enabled by a different command. The linkUpDown notifications are controlled by the snmp trap link-status command. If you enter this command with no notification-type keywords, the default is to enable all notification types controlled by this command.


Specify the trap types if you don't want all traps to be sent. Then use multiple snmp-server enable traps commands, one for each of the trap types that you used in the snmp host command.

For detailed information about notifications and a list of notification types, go to the following URLs:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios113ed/113t/113t_1

http://www.cisco.com/warp/public/477/SNMP/SNMPTrapsInImages.html

http://www.cisco.com/en/US/docs/ios/12_2/configfun/configuration/guide/fcf014.html

Enabling Notifications

You can enable MIB notifications using either of the following procedures:

Command line interface (CLI)—Specify the recipient of the trap message and specify the types of traps sent. This command also specifies which types of informs are enabled. For detailed procedures, go to:

http://www.cisco.com/warp/public/477/SNMP/SNMPTrapsInImages.html

http://www.cisco.com/en/US/docs/ios/11_3/feature/guide/snmpinfm.html

Performing an SNMP SET operation using the setany command— To enable or disable MIB notifications, perform an SNMP SET operation on the a specific object.

To enable the notifications set the object to true(1)

To disable the notifications, set the object to false(2)

For detailed procedures, go to:
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/catos/6.x/configuration/guide/snmp.html


Note If you issue the snmp-server enable traps command without a notification-type argument, the router generates traps for all types of events, which might not be desirable. Some MIBs require the user to set additional objects to enable some notifications.


Cisco SNMP Notifications

This section contains tables that describe a MIB event, why the event occurred, and a recommendation as to how to handle the event. Each table lists the following information:

Text string—The event display

Brief description—What the event indicates

Probable cause—What might have caused the notification

Recommended action—Recommendation as to what should be done when the particular notification occurs


Note In the following tables, where no action required is documented, there might be instances where an application, such as trouble ticketing occurs. For detailed information, go to the following URL:
http://www.cisco.com/en/US/docs/net_mgmt/cisco_info_center/3.0/installation/guide/overview.html


Environmental or Functional Notifications

Table 4-1 lists notifications generated for events that might indicate the failure of the Cisco 7600 Series router or conditions that might affect the router's functionality.

Table 4-1 Environmental and Functional Notifications 

Event
Description
Probable Cause
Recommended Action
cefcModuleStatusChange

Indicates that the status of a module has changed.

Module has unknown state

Enter the show module command to view error message details. For Syslog messages associated with this event, consult Messages and Recovery Procedures.

   

Module is operational

No action is required.

   

Module has failed due to some condition

Enter the show module command to view error message details. For Syslog messages associated with this event, consult Messages and Recovery Procedures.

cefcPowerStatusChange

Indicates that the power status of a field replaceable unit has changed.

FRU is powered off because of an unknown problem.

Enter the show power command to check the actual power usage.For Syslog messages associated with this event, consult Messages and Recovery Procedures

   

FRU is powered on

No action is required.

   

FRU is administratively off

No action is required.

   

FRU is powered off because available system power is insufficient

Enter the show power command to check the actual power usage.

cefcFRUInserted

Indicates that a FRU was inserted.

A new field replaceable unit like Flex-Wan, OSM line card, SIP and SPA modules, fan, port, power supply, or redundant power supply was added.

No action is required.

cefcFRURemoved

Indicates that a FRU was removed.

A field replaceable unit like Flex-Wan, OSM line cards, SIP and SPA modules, fan, ports, power supply, or redundant power supply was removed.

Replace the field replaceable unit.

chassisAlarmOn

Indicates that a FRU status has changed. The chassisTempAlarm, chassisMinorAlarm, or chassisMajorAlarm object in this MIB has changed to the on (2) state.

The chassis temperature is too high, a minor or major alarm has been detected.

Inspect the indicated component closely to determine why it is operating out of the normal operating temperature range and whether it will eventually exceed the allowed operating temperature range.

   

A redundant power supply has been powered off.

Replace the field replaceable unit.

 

Router's cooling fan could be close to failure.

One or more fans in the system fan tray have failed. Although this is a minor alarm, system components could overheat and be shut down.

Replace the fan as soon as possible or the system might shut itself down or fail to operate properly.

chassisAlarmOff

Indicates that a FRU status has changed. The chassisTempAlarm, chassisMinorAlarm, or chassisMajorAlarm object in this MIB has changed to the off (1) state.

A redundant power supply has been powered on.

No action required.

dsx1LineStatusChange

The dsx1LineStatus is a bit map that contains loopback state and failure state information.

When a failure is detected, the corresponding dsx1LineStatus bit should change to reflect the failure. For example, when a Receiving LOS failure is detected, the corresponding bit (bit 64) should be set to indicate the failure and as a result the dsx1LineStatus changes.

When the dsx1LineStatus reports failures, the recommended action is correction of the conditions causing the error.

cdcVFileCollectionError

Indicates that data collection operations for a cdcVFileEntry has encountered an error

   
cdcFileXferComplete

A file transfer to the destination specified by the cdcVFileMgmtLastXferURL variable, has completed with the status specified by the cdcVFileMgmtLastXferStatus variable.

File transfer complete

None


Table 4-2 lists ENTITY-MIB notifications generated by Cisco 7600 Series router line cards.

Table 4-2 FlexWAN and OSM Card Notifications 

Event
Description
Probable Cause
Recommended Action
entConfigChange

An entry for the line card is removed from the entPhysicalTable (which causes the value of entLastchangeTime to change).

A line card was removed.

Replace the field replaceable unit.

cefcModuleOperStatus

Indicates that the line card operational state changed. A management application uses this trap to update the status of a module that it is managing.

A line card is provisioned for a slot but it is not present in the slot.

Add a module.

entSensorThresholdNotification

Indicates that the sensor value crossed the threshold. This variable reports the most recent measurement seen by the sensor and This variable indicates the value of the threshold.

The sensor value in a module crossed the threshold listed in entSensorThresholdTable, This notification is generated once each time the sensor value crosses the threshold.

Remove the configuration that bypasses the module shutdown due to sensor thresholds being exceeded. Shut down the module after removing the configuration. It exceeded major sensor thresholds.

Note The command that shuts down the module in the event of a major sensor alarm has been overridden, so the specified module will not be shut down. The command used to override the shutdown is no environment-monitor shutdown.

   

The local CPU on the FlexWAN was unable to access the temperature sensor on the module. The module will attempt to recover by resetting itself.

Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

ceAlarmAsserted

The agent generates this trap when a physical entity asserts an alarm.

You manually shut down the PA, then you get the PA error.

Check the entPhysicalDescr type and take the corresponding action; because there are many types of asserted alarms.

ceAlarmCleared

The agent generates this trap when a physical entity clears a previously asserted alarm.

The agent generates this trap when a physical entity clears a previously asserted alarm.

No action required.

Notes:

* Sensor entities are the physical entities whose entity class must be defined to type entity sensor(8) in the entPhysicalTable.

* Notifications happen only if the particular entity has an entry in entity table.

* If ceAlarmNotifiesEnable is set to 0, it disables ceAlarmAsserted and ceAlarmCleared notifications. Similarly, when ceAlarmSyslogEnable is set to 0, it disables syslog messages corresponding to alarms.

* If ceAlarmHistTableSize is set to 0, it prevents any history from being retained in the ceAlarmHistTable. In addition whenever the ceAlarmHistTableSize is reset (either increased or decreased) the existing log is deleted.

* When a new alarm condition is detected, the carrier alarm LEDs in the individual line cards are currently set by the line card software. The IOS alarm subsystem does not control the LEDs.


Flash Card Notifications

Table 4-3 lists CISCO-FLASH-MIB notifications generated by Cisco 7600 Series router flash cards. These notifications indicate the failure of a flash card or error conditions on the card that might affect the functionality of all interfaces and connected custom

Table 4-3 Flash Card Notifications 

Event
Description
Probable Cause
Recommended Action
ciscoFlashDeviceChangeTrap

Indicates a removable flash device was inserted into the router.

Status change occurred.

To determine which flash card was inserted, check the ciscoFlashDeviceTable.

 

Indicates removable flash card is removed from the router.

Status change occurred.

To determine which flash card was inserted, check the ciscoFlashDeviceTable.


Interface Notifications

Table 4-4 lists notifications generated by the router for link-related (interface) events.

Table 4-4 Interface Notifications 

Event
Description
Probable Cause
Recommended Action
linkDown

Indicates that a link is about to enter the Down state, which means it can not transmit or receive traffic. The ifOperStatus object shows the link's previous state. Value is down(2).

An internal software error might have occurred.

To see if link traps are enabled or disabled on an interface, check ifLinkUpDownTrapEnable (IF-MIB) for the interface. To enable link traps, set ifLinkUpDownTrapEnable to enabled(1).

Enable the IETF (RFC 2233) format of link traps by issuing the CLI command snmp-server trap link ietf.

linkUp

Indicates that a link's status is no longer down. The value of ifOperStatus indicates the link's new state. Value is up(1).

The port manager reactivated a port in the link-down state during a switchover.

No action is required.


Cisco MPLS Notifications

Table 4-5 lists MPLS notifications that can occur when an environmental threshold is exceeded.

Table 4-5 MPLS-VPN Notifications 

Event
Description
Probable Cause
Recommended Action
mplsNumVrfRouteMidThreshExceeded

Indicates that the warning threshold is exceeded.

Indicates that a threshold violation occurred.

The system limit of four route processors per VPN has been exceeded. The number of routes created has crossed the warning threshold. This warning is sent only at the time the warning threshold is exceeded.

The configured RPs are too large to fit in the DF table for one VPN. Try to configure the groups among existing RPs in the hardware, or configure the RP in another VPN.

mplsNumVrfRouteMaxThreshExceeded

Indicates that the maximum route limit was reached.

A route creation was unsuccessful because the maximum route limit was reached. Another notification is not sent until the number of routes falls below the maximum threshold and reaches the maximum threshold again.

Set the threshold value. The max-threshold value is determined by the maximum routes command in VRF configuration mode.

mplsLdpFailedInitSessionThreshold
Exceeded

Indicates that a local LSR and an adjacent LDP peer attempt to set up an LDP session between them, but fail to do so after a specified number of attempts.

Eight failed attempts occurred to establish an LDP session between a local LSR and an LDP peer, due to some type of incompatibility between the devices.

Cisco routers support the same features across multiple platforms. Therefore, the most likely incompatibility to occur between Cisco LSRs is a mismatch of their respective ATM VPI/VCI label ranges.

If you specify a range of valid labels for an LSR that does not overlap the range of its adjacent LDP peer, the routers will try eight times to create an LDP session between themselves before the mplsLdpFailedInitSessionThresholdExceedednotification is generated and sent to the NMS as an informational message.

Operationally, the LSRs whose label ranges do not overlap continue their attempt to create an LDP session between themselves after the eight retry threshold is exceeded.

In such cases, the LDP threshold exceeded notification alerts the network administrator to the existence of a condition in the network that may warrant attention.


Service Notifications

Table 4-6 lists service notifications generated by the router to indicate conditions for services.

Table 4-6 MPLS-Service Notifications 

Event
Description
Probable Cause
Recommended Action
mplsVrfIfUp

Indicates that a VPN routing or forwarding instance (VRF) was assigned to an interface that is operational or for the transition of a VRF interface to the operationally up state.

A VPN routing or forwarding instance (VRF) was assigned to an interface that is operational or a VRF interface transitions to the up state.

No action is required.

mplsVrfIfDown,
Indicates that a VRF was removed from an interface or a VRF interface transitioned to the operationally up state.

A VRF was removed from an interface or a VRF of an interface transitioned to the down state.

Check the operation state of the interface OR the state of the connected interface on the adjacent router OR add the removed VRF.

mplsLdpSessionUp

Indicates that the MPLS LDP session is in the up state.

Trap generated when an LDP entity (a local LSR) establishes an LDP session with another LDP entity (an adjacent LDP peer in the network).

No action is required.

mplsLdpSessionDown

Indicates that the MPLS LDP session is in the down state.

Trap generated when an LDP session between a local LSR and its adjacent LDP peer is terminated.

Check if the LDP session exists between the local LSR and adjacent LDP peer.

mplsLdpPVLMismatch

Indicates that a local LSR establishes an LDP session with its adjacent peer LSR, but the two LSRs have dissimilar path vector limits.

An LDP session has two adjacent peer LSRs with dissimilar path vector limits.

The value of the path vector limit can range from 0 through 255; a value of "0" indicates that loop detection is off; any value other than zero up to 255 indicates that loop detection is on.

Configure all LDP-enabled routers in the network with the same path vector limit. Accordingly, the mplsLdpPathVectorLimitMismatch object exists in the MPLS LDP MIB to provide a warning message to the NMS when two routers engaged in LDP operations have a dissimilar path vector limit.

mplsTunnelUp

Indicates that a mplsTunnelOperStatus object for a configured tunnel is about to transition from the Down state to any state except NotPresent.

A configured tunnel transitioned from the Down state to any state except NotPresent.

May be caused by an administrative or operational status check of the tunnel.

No action is required.

mplsTunnelDown

Indicates that the mplsTunnelOperStatus object for a configured MPLS traffic engineering tunnel is about to transition to the up(1) or the down(2) respectively.

A configured tunnel is transitioning to the down state.

May be caused by an administrative or operational status check of the tunnel.

 
mplsTunnelRerouted

Indicates that the signalling path for an MPLS traffic engineering tunnel changed.

A tunnel was rerouted or reoptimized.

If you use the actual path, then write the new path to mplsTunnelRerouted after the notification is issued.


Routing Protocol Notifications

Table 4-7 lists BGP4-MIB notifications which are Border Gateway Protocol (BGP) state changes generated by the Cisco 7600 Series router to indicate error conditions for routing protocols and services.

Table 4-7 Routing Protocol Notifications 

Event
Description
Probable Cause
Recommended Action
bgpEstablished

The BGP FSM enters the ESTABLISHED state. It becomes active on the router.

The BGP routing protocol changed status.

No action is required.

bgpBackwardTransition

Indicates that the BGP protocol transitions from a higher-level state to a lower-level state. The prefix count for an address family on a BGP session exceeded the configured threshold value.

The BGP routing protocol changed status.

This threshold value is configured using the CLI command, neighbor <nbr_addr> <max_prefixes> [ theshold] [warning-only]

MPLS VPN VRF Up/Down

MPLS-VPN-MIB

   
mplsVrfUp

mplsVpnInterfaceConfIndex
mplsVpnVrfName

Notification generated when specified VRF is initialized or its status changes to `up' state.

 
mplsVrfDown

mplsVpnInterfaceConfIndex
mplsVpnVrfName

Notification generated when specified VRF is initialized or its status transitions from the `up' state.

 

Chassis Notifications

Table 4-8 lists CISCO-STACK-MIB notifications generated by the router to indicate that a chassis module has become active or stopped responding. These notifications are supported by the Cisco 7600 series Internet router.

Table 4-8 Chassis Notifications 

Event
Description
Probable Cause
Recommended Action
moduleDown

The status of a module changes from the OK state to another state.

The agent entity has detected that the moduleStatus object in this MIB has transitioned to the ok (2) state for one of its modules. The generation of this trap can be controlled by the sysEnableModuleTraps object in this MIB.

Enter the show module command and check the status.

moduleUp

The status of a module changes to the OK state.

The agent entity has detected that the moduleStatus object in this MIB has transitioned out of the ok (2) state for one of its modules. The generation of this trap can be controlled by the sysEnableModuleTraps object in this MIB.

No action required.


RTT Monitor Notifications

Table 4-9 lists CISCO-RTTMON-MIB notifications that can occur during round-trip time (RTT) monitoring.

Table 4-9 RTT Monitor Notifications 

Event
Description
Probable Cause
Recommended Action
rttMonConnectionChangeNotification

Sent when the value of rttMonCtrlOperConnectionLostOccurred changes.

Occurs when the connection to a target has either failed to be established or was lost and then re-established.

Check for the connectivity to the target. There could be link problems to the target through different hops.

rttMonTimeoutNotification

A timeout occurred or was cleared.

An RTT probe occurred and the system sends the notice when the value of rttMonCtrlOperTimeoutOccurred changes.

Check for the end-to-end connectivity if rttMonCtrlOperTimeoutOccurred if the notification returns true.

No action is required if rttMonCtrlOperTimeoutOccurred is false.

rttMonThresholdNotification

Threshold violation occurred.

An RTT probe occurred or a previous violation has subsided in a subsequent RTT operation.

Check for the end-to-end connectivity if rttMonCtrlOperOverThresholdOccurred in the notification is true otherwise no action required.


Environmental Notifications

Table 4-10 lists CISCO-ENVMON-MIB notifications generated for events that might indicate the failure of the Cisco 7600 Series router or conditions that might affect the router's functionality.

Table 4-10 Environmental Notifications 

Event
Description
Probable Cause
Recommended Action
ciscoEnvMonShutdownNotification

A ciscoEnvMonShutdown
Notification is sent if the environmental monitor detects a testpoint reaching a critical state and is about to initiate a shutdown. This notification contains no objects so that it may be encoded and sent in the shortest amount of time possible. Management applications should not rely on receiving such a notification as it may not be sent before the shutdown completes.

A test point nears a critical state and the router is about to shut down (for example, if auto-shutdown is enabled and the chassis core or inlet temperature reaches critical state and remains there for more than 2 minutes).

The system has a configuration to shut down a module if its operating temperature exceeds a temperature threshold. This configuration has been bypassed, and a module will still operate in an over-temperature condition. Operating at an over-temperature condition can damage the hardware.

Do not override the sensor alarms that act on an over-temperature condition. Enter the environment-monitor shutdown temperature command to bring the system back to standard temperature detection.

   

One or more fans in the system fan tray have failed. Although this is a minor alarm, system components could overheat and be shut down.

Replace the system fan tray.

ciscoEnvMonRedundantSupplyNotification

Sent if the redundant power supply (if available) fails.

An environmental condition, an over-temperature condition, or inconsistent voltage to the module occurred. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification.

Ensure that the system power supplies are optimally redundant. Use power supplies with identical output ratings or reduce system power consumption.

ciscoEnvMonTempStatusChangeNotif

The core or inlet temperature is outside its normal range, when ciscoEnvMonState is at the Warning or Critical state.

Since such a Notification is usually generated before the shutdown state is reached,it can convey more data and has a better chance of beingsent than does the ciscoEnvMonShutdownNotification.

During previous reloads, this module experienced a timeout while accessing the temperature sensor. All further access to the temperature sensor will be disabled. This condition indicates a possible problem with the temperature sensor.

Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

* The cefcFRUPowerAdminStatus is on(1) when a redundant power supply is disabled. When there is a redundant power supply, the cefcFRUPowerAdminStatus is always on(1) for both power supplies, regardless if the redundant power supply is disabled.

 

Redundancy Framework Notifications

Table 4-11 lists CISCO-RF-MIB notifications that can occur in a redundant system. There are two types of notifications:

Switch of Activity (SWACT)—Either a forced or automatic switch of active status from the active unit to the standby unit. The former standby unit is now referred to as the active unit.

Progression—The process of making redundancy state of the standby unit equivalent to that of the active unit. This includes transitioning the RF state machine through several states which drives the RF clients on the active unit to synchronize any relevant data with their peer on the standby unit.

Table 4-11 Redundancy Framework Notifications 

Event
Description
Probable Cause
Recommended Action
ciscoRFSwactNotif

Indicates that the RF state changed.

A switch of activity notification is sent by the newly active redundant unit.

A switch of activity occurs. If a SWACT event is indistinguishable from a reset event, then a network management station should use this notification to differentiate the activity.

If the switchover occurred due to active unit failed indicated by cRFStatusLastSwactReasonCode, see if there is any hardware failures, otherwise no action is required.

ciscoRFProgressionNotif

Indicates that the RF state changed.

The active redundant unit RF state changed or the RF state of the peer unit changed.

To avoid an increase of notifications for all state transitions, send notifications for transitions to the following RF states:

standbyCold(5)

standbyHot(9)

active(14)

activeExtraload(15)


CPU Usage Notifications

Table 4-12 lists CISCO-PROCESS -MIB notifications that can occur.

Table 4-12 CISCO-PROCESS-MIB Notifications 

Event
Description
Probable Cause
Recommended Action
cpmCPURisingThreshold

Indicates the rising threshold for system wide CPU utilization.

When the system wide CPU utilization crosses (exceeds) the rising threshold, a notification (SNMP/Syslog) is generated.

After sending a rising threshold notification, a second rising threshold notification will be sent only if a falling threshold notification corresponding to the first rising threshold notification has been sent.

what should be done?

cpmCPUFallingThreshold

Indicates the falling threshold for system wide CPU utilization.

If the system-wide CPU utilization falls below the falling threshold a notification is generated.

The falling threshold notification is generated only if a rising threshold notification had been sent out previously.