Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This section explains the objectives, intended audience, and organization of this publication and describes the conventions that convey instructions and other information.
•Updated the table "OTU2_XP Line Settings" in the chapter "Provision Transponder and Muxponder Cards".
•Updated the table "FC Variables of the 40G-MXP-C, 40E-MXP-C, and 40ME-MXP-C Cards" in the chapter "Provision Transponder and Muxponder Cards".
•Updated "DLP-G629 Create a MEP Using CTC" in the chapter "Provision Transponder and Muxponder Cards".
•Updated the table "Ranges, Values, and Edit Options for the ANS Parameters" in the chapter "Node Reference".
•Updated the section "DLP-G681 Modify an ANS Parameter" in the chapter "Turn Up a Node".
•Updated the "Provision the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE Card Ethernet Settings" procedure in the chapter "Provision Transponder and Muxponder Cards".
•Updated the sections "40E-TXP-C and 40ME-TXP-C Cards" and "40G-MXP-C, 40E-MXP-C, and 40ME-MXP-C Cards" in the chapter "Provision Transponder and Muxponder Cards".
September 2011
•Updated the key features section of TXP_MR_10G, TXP_MR_10E, TXP_MR_10E_C, TXP_MR_10E_L, TXP_MR_10EX_C, and OTU2_XP cards in the chapter "Provision Transponder and Muxponder Cards".
•Updated a note in "NTP-G198 Create 1+1 Protection for GE_XP, 10GE_XP, GE_XPE, or 10GE_XPE Cards" in the chapter "Provision Transponder and Muxponder Cards".
•Replaced G.975.1 with G.975.1 I.7 and added a note in the "Enhanced FEC (E-FEC) Feature" section in the appendix, "Card Features".
•Created a "Summary Pane" section in the chapter "Cisco Transport Controller Operation, Information, and Shortcuts".
October 2011
•Updated the "DLP-G384 Provision the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE QinQ Settings", "DLP-G470 Provision the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE Class of Service (CoS) Settings", "DLP-G380 Provision the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE Card Ethernet Settings", and "DLP-G460 Enable MAC Address Learning on SVLANs for GE_XPE or 10GE_XPE Cards" procedures in the chapter "Provision Transponder and Muxponder Cards".
•Updated the MPLS Inner Label and MPLS Outer Label range values in the table "GE_XPE Card PDH Ethernet Settings " in the chapter "Provision Transponder and Muxponder Cards".
•Updated the "DLP-G471 Create a SVLAN or CVLAN Profile" in the chapter "Provision Transponder and Muxponder Cards".
•Removed the Temperature table and updated the Temperature section with standard operating temperature values, removed the Environmental section from all the 15454 card specifications, and added "Environmental Exception" to "40G-MXP-C, 40E-MXP-C and 40ME-MXP-C Card Specifications" section in the appendix "Hardware Specifications."
•Updated information related to IB_5G in the chapter "Provision Transponder and Muxponder Cards".
•Updated the figure "Scenario 3: Using Proxy ARP with Static Routing (ANSI and ETSI)" in the chapter "Management Network Connectivity".
December 2011
•Updated the procedure "DLP-G76 Provision DCC/GCC Terminations" in the chapter "Create Optical Channel Circuits and Provisionable Patchcords".
•Updated the section "Termination Modes" in the chapter "Card Features".
January 2012
•Added a note to step 3 in NTP-G144 in the chapter, "Turn Up a Node".
•Updated the card description for the RAMAN-CTP and RAMAN-COP cards in the chapter, "Provision Optical Amplifier Cards".
•Updated the section "DLP-G645 Create a Segment Using CTC" in the chapter "Provision Transponder and Muxponder Cards".
February 2012
•Updated the procedure "DLP-G379 Change the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE Card Mode" in the chapter "Provision Transponder and Muxponder Cards".
•Removed the autonegotiation support statement for ADM-10G card from the "Key Features" section and updated the Mode parameter in the table "ADM-10G Card Ethernet Settings" in the chapter "Provision Transponder and Muxponder Cards".
•Updated the procedure "DLP-G278 Provision the Optical Line Rate" in the chapter "Provision Transponder and Muxponder Cards".
March 2012
•Updated the bandwidth parameter in the procedure, "DLP-G383 Provision the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE Quality of Service Settings".
•Updated the section, "Multishelf Node" in the chapter, " Node Reference".
•Added a note in the procedure "NTP-G242 Create an Internal Patchcord Manually" in the chapter "Turn Up a Node".
April 2012
•Updated the "Functional View for an Eight-Sided Node" diagram in the chapter "Node Reference".
•Added a note in the "Displaying Optical Power" section of chapter, "Node Reference".
•Updated the "Faceplate and Block Diagram" section of "GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE Cards" in the chapter, "Provision Transponder and Muxponder Cards".
•Added a note in the procedure "DLP-G368 Change the 10G Multirate Transponder Trunk Wavelength Settings" in the chapter "Provision Transponder and Muxponder Cards".
•Added a new procedure "DLP-G713 Provision Administrative VLAN for Ports in a REP Segment Using CTC" and updated "DLP-G384 Provision the GE_XP, 10GE_XP, GE_XPE, and 10GE_XPE QinQ Settings" in the chapter, "Provision Transponder and Muxponder Cards".
May 2012
•Added a note in the procedure "DLP-G507 Enable a Different GE_XP, 10GE_XP, GE_XPE, or 10GE_XPE Card as the Master Card" in the chapter "Provision Transponder and Muxponder Cards".
•Updated the section "Optical Channel Circuits" in the chapter "Create Optical Channel Circuits and Provisionable Patchcords".
•Updated the "Set Up SNMP" procedure in the chapter "Turn Up a Node".
June 2012
Updated the section "OTU2_XP Card Configuration Rules" in the chapter "Provision Transponder and Muxponder Cards".
July 2012
•Document Part Number revisioned to 78-19909-02 and a full-length book PDF was generated.
•Updated the table "Gigabit Ethernet RMON Variables" in the chapter "Provision Transponder and Muxponder Cards".
August 2012
Updated the table "Platform and Software Release Compatibility for Control Cards" in the chapter "Install the Control Cards".
Document Objectives
The Cisco ONS 15454 DWDM Configuration Guide includes content previously found in two separate guides—Cisco ONS 15454 DWDM Reference Manual and Cisco ONS 15454 DWDM Procedure Guide.
The new Cisco ONS 15454 DWDM Configuration Guide, Release 9.3 and later releases will now include background and reference material, installation, turn up, provisioning, and maintenance procedures for the Cisco ONS 15454, Cisco ONS M2, and Cisco ONS M6 dense wavelength division (DWDM) systems. Use this document in conjunction with the appropriate publications listed in the Related Documentation section.
Audience
To use this publication, you should be familiar with Cisco or equivalent optical transmission hardware and cabling, telecommunications hardware and cabling, electronic circuitry and wiring practices, and preferably have experience as a telecommunications technician
Document Organization
Table 1 Cisco ONS 15454 Configuration Guide Chapters
Explains the Tunable Dispersion Compensating Units (T-DCU) used in Cisco ONS 15454 dense wavelength division multiplexing (DWDM) networks. Also provides references to related procedures.
Includes descriptions of the Protection Switching Module (PSM) card used in Cisco ONS 15454 DWDM networks. Also provides references to related procedures.
Includes descriptions of transponder (TXP), muxponder (MXP), Xponder (GE_XP, 10GE_XP, GE_XPE and 10GE_XPE), and ADM-10G cards. Also provides references to related procedures.
Explains the DWDM node types available for the ONS 15454. The DWDM node type is determined by the type of amplifier and filter cards that are installed in an ONS 15454. Also explains the DWDM automatic power control (APC), reconfigurable optical add/drop multiplexing (ROADM) power equalization, span loss verification, and automatic node setup (ANS) functions.
Explains how to modify node provisioning for the Cisco ONS 15454 and perform common management tasks such as monitoring the DWDM automatic power control (APC) and span loss values.
Provides an overview of ONS 15454 data communications network (DCN) connectivity. Cisco Optical Networking System (ONS) network communication is based on IP, including communication between Cisco Transport Controller (CTC) computers and ONS 15454 nodes, and communication among networked ONS 15454 nodes. The chapter shows common Cisco ONS 15454 IP network configurations and includes detailed data communications network (DCN) case studies.
Provides procedures for maintaining the Cisco ONS 15454, including database backup and restoration, removing and replacing cards, viewing the ONS 15454 audit trail, and hardware maintenance procedures.
Describes the administrative and service states for Cisco ONS 15454 DWDM cards, optical payload ports, out-of-band optical service channel (OSC) ports, optical channel network connections (OCHNCs), and transponder/muxponder cards and ports.
Keywords or arguments that appear within square brackets are optional.
{ x | x | x }
A choice of keywords (represented by x) appears in braces separated by vertical bars. The user must select one.
Ctrl
The control key. For example, where Ctrl + D is written, hold down the Control key while pressing the D key.
screen font
Examples of information displayed on the screen.
boldface screen font
Examples of information that the user must enter.
< >
Command parameters that must be replaced by module-specific codes.
Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the document.
Caution Means reader be careful. In this situation, the user might do something that could result in equipment damage or loss of data.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071
SAVE THESE INSTRUCTIONS
Waarschuwing
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen.
BEWAAR DEZE INSTRUCTIES
Varoitus
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla.
SÄILYTÄ NÄMÄ OHJEET
Attention
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
Avvertenza
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
Advarsel
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten.
TA VARE PÅ DISSE INSTRUKSJONENE
Aviso
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.
GUARDE ESTAS INSTRUÇÕES
¡Advertencia!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES
Varning!
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.
SPARA DESSA ANVISNINGAR
Aviso
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo.
GUARDE ESTAS INSTRUÇÕES
Advarsel
VIGTIGE SIKKERHEDSANVISNINGER
Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed.
For safety and warning information, refer to the Cisco Optical Transport Products Safety and Compliance Information document that accompanied the product. This publication describes the international agency compliance and safety information for the Cisco ONS 15454 system. It also includes translations of the safety warnings that appear in the ONS 15454 system documentation.
Optical networking-related documentation, including Cisco ONS 15xxx product documentation, is available in a CD-ROM package that ships with your product. The Optical Networking Product Documentation CD-ROM is updated periodically and may be more current than printed documentation.
Obtaining Documentation, Obtaining Support, and Security Guidelines
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation.
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS Version 2.0.