Table Of Contents
NPE-G2 Support for the show environment Command
Feature Information for NPE-G2 Support for the show environment Command
NPE-G2 Support for the show environment Command
First Published: May 10, 2006Last Updated: May 3, 2006The output of the show environment command has been modified to support the NPE-G2 Network Processing Engine on the Cisco 7200 VXR in Cisco IOS Release 12.4(4)XD. No other changes to the Cisco IOS software were made.
Finding Feature Information in This Module
Your Cisco IOS software release may not support all of the features documented in this module. To reach links to specific feature documentation in this module and to see a list of the releases in which each feature is supported, use the "Feature Information for NPE-G2 Support for the show environment Command" section.
Finding Support Information for Platforms and Cisco IOS and Catalyst OS Software Images
Use Cisco Feature Navigator to find information about platform support and Cisco IOS and Catalyst OS software image support. To access Cisco Feature Navigator, go to http://www.cisco.com/go/cfn. An account on Cisco.com is not required.
Contents
Additional References
The following sections provide references related to the NPE-G2 Support for the show environment Command feature.
Related Documents
Related Topic Document Titleshow environment command, Cisco IOS Release12.4T (without NPE-G2 output changes)
Cisco IOS Configuration Fundamentals Command Reference, Release 12.4T
Standards
Standard TitleNo new or modified standards are supported by this feature, and support for existing standards has not been modified by this feature.
—
MIBs
RFCs
RFC TitleNo new or modified RFCs are supported by this feature, and support for existing RFCs has not been modified by this feature.
—
Technical Assistance
Command Reference
This section documents the following modified command:
•
show environment
show environment
To display temperature, voltage, fan, and power supply information on the Cisco 7000 series, Cisco 7200 series, NPE-G2 in Cisco 7200 VXR routers, Cisco 7304 routers, Cisco 7500 series routers, Cisco 3600 series routers, Cisco AS5300 series access servers, and Cisco 12000 series Gigabit Switch Routers (GSRs), use the show environment command in user EXEC or privileged EXEC mode.
show environment [alarms | all | fans | hardware | last | leds | power-supply | table | temperature | voltages]
On the Cisco 7000 Series, Cisco 7200 Series, Cisco 7304, and Cisco 7500 Series Routers
show environment [all | last | table]
Syntax Description
Defaults
If no options are specified, the default is all.
Command Modes
User EXEC
Privileged EXEC
Command History
Usage Guidelines
The availability of keywords will depend on your system and platform. The command does not support SPAs on the Cisco 7200 series and on the NPE-G2 in the Cisco 7200 VXR routers.
A routine runs once a minute that reads environmental measurements from sensors and stores the output into a buffer. For shared port adapters (SPAs), the temperature and voltage sensors are read every few seconds to get environmental data. The environmental buffer is displayed on the console when you use the show environment command.
If a measurement exceeds desired margins, but has not exceeded fatal margins, a warning message is printed to the system console. The system software queries the sensors for measurements once a minute, but warnings for a given test point are printed at most once every hour for sensor readings in the warning range and once every 5 minutes for sensor readings in the critical range. If a measurement is out of line within these time segments, an automatic warning message appears on the console. As noted, you can query the environmental status with the show environment command at any time to determine whether a measurement is at the warning or critical tolerance.
A SPA is shut down when any of the SPA environment readings exceed the shutdown threshold.
If a shutdown occurs because of detection of fatal environmental margins, the last measured value from each sensor is stored in internal nonvolatile memory.
For environmental specifications, refer to the hardware installation and configuration publication for your individual chassis.
For network processor engines (NPEs), network services engines (NSEs), line cards, and modular services cards (MSCs), environmental information is recorded in the CISCO-ENVMON-MIB. SPAs are not supported by the CISCO-ENVMON-MIB. In Cisco IOS Release 12.2(20)S2 and later, the CISCO-ENTITY-SENSOR-MIB supports environmental information for SPAs, as well as NPEs, NSEs, line cards, and MSCs.
If the Cisco 12000 series GSR exceeds environmental conditions, a message similar to the following is displayed on the console:
%GSR_ENV-2-WARNING: Slot 3 Hot Sensor Temperature exceeds 40 deg C;Check cooling systems
Note
Blower temperatures that exceed environmental conditions do not generate a warning message.
You can also enable Simple Network Management Protocol (SNMP) notifications (traps or informs) to alert a network management system (NMS) when environmental thresholds are reached using the snmp-server enable traps envmon and snmp-server host global configuration commands.
Whenever Cisco IOS software detects a failure or recovery event from the DRPS unit, it sends an SNMP trap to the configured SNMP server. Unlike console messages, only one SNMP trap is sent when the failure event is first detected. Another trap is sent when the recovery is detected.
Cisco AS5300 DRPS software reuses the MIB attributes and traps defined in CISCO-ENVMON-MIB and CISCO-ACCESS-ENVMON-MIB. CISCO-ENVMON-MIB is supported by all Cisco routers with RPS units, and CISCO-ACCESS-ENVMON-MIB is supported by the Cisco 3600 series routers.
A power supply trap defined in CISCO-ENVMON-MIB is sent when a failure is detected and when a failure recovery occurs for the following events: input voltage fail, DC output voltage fail, thermal fail, and multiple failure events.
A fan failure trap defined in CISCO-ENVMON-MIB is sent when a fan failure or recovery event is detected by Cisco IOS software.
A temperature trap defined in CISCO-ACCESS-ENVMON-MIB is sent when a board over-temperature condition is detected by Cisco IOS software.
CISCO-ACCESS-ENVMON-MIB also defines an over-voltage trap. A similar trap is defined in CISCO-ENVMON-MIB, but it requires the ciscoEnvMonVoltageStatusValue in varbinds. This value indicates the current value of the voltage in the RPS. With Cisco AS5300 RPS units, the current voltage value is not sent to the motherboard.
CISCO-ENVMON-MIB is extended to add a new enumerated value, internalRedundant(5), for MIB attribute ciscoEnvMonSupplySource. This is used to identify a RPS unit.
Examples
In the following example, the typical show environment display is shown when no warning conditions are in the system for the Cisco 7000 series and Cisco 7200 series routers. This information may vary slightly depending on the platform you are using. The date and time of the query are displayed, along with the data refresh information and a message indicating that there are no warning conditions.
Router> show environmentEnvironmental StatisticsEnvironmental status as of 13:17:39 UTC Thu Jun 6 1996Data is 7 second(s) old, refresh in 53 second(s)All Environmental Measurements are within specificationsTable 1 describes the significant fields shown in the display.
NPE-G2 in Cisco 7200 VXR Routers Examples
In the following example, additional temperature and voltage readings for the NPE-G2 in the Cisco 7200 VXR router are displayed by the show environment all command. Power supplies 1 and 2 are on, and all monitored variables are within the normal operating range.
Router_npe-g2# show environment allPower Supplies:Power Supply 1 is Zytek AC Power Supply. Unit is on.Power Supply 2 is Zytek AC Power Supply. Unit is on.Temperature readings:NPE Inlet measured at 25C/77FNPE Outlet measured at 28C/82FCPU Die measured at 56C/132F =======> additional temperature reading on NPE-G2Voltage readings:+3.30 V measured at +3.32 V =======> additional voltage reading on NPE-G2+1.50 V measured at +1.48 V =======> additional voltage reading on NPE-G2+2.50 V measured at +2.46 V =======> additional voltage reading on NPE-G2+1.80 V measured at +1.75 V =======> additional voltage reading on NPE-G2+1.20 V measured at +1.17 V =======> additional voltage reading on NPE-G2VDD_CPU measured at +1.28 V =======> additional voltage reading on NPE-G2VDD_MEM measured at +2.50 V =======> additional voltage reading on NPE-G2VTT measured at +1.25 V =======> additional voltage reading on NPE-G2+3.45 V measured at +3.39 V-11.95 measured at -11.93 V+5.15 V measured at +4.96 V+12.15 V measured at +12.18 VEnvm stats saved 0 time(s) since reload
In the following example, the show environment last command displays the previously saved measurements (readings) from the last environmental reading before the router was shut down. The command also displays the reason why the router was shut down, which was "power supply shutdown" in this case.
Router_npe-g2# show environment lastNPE Inlet previously measured at 26C/78FNPE Outlet previously measured at 28C/82FCPU Die previously measured at 56C/132F+3.30 V previously measured at +3.32+1.50 V previously measured at +1.48+2.50 V previously measured at +2.46+1.80 V previously measured at +1.75+1.20 V previously measured at +1.17VDD_CPU previously measured at +1.28VDD_MEM previously measured at +2.50VTT previously measured at +1.25+3.45 V previously measured at +3.39-11.95 previously measured at -11.93+5.15 V previously measured at +4.96+12.15 V previously measured at +12.18last shutdown reason - power supply shutdownRouter_npe-g2#
In the following example, the show environment table command displays threshold levels in a table format of the environmental monitor parameters. It displays the high warning, high critical, and high shutdown temperature thresholds of the NPE inlet, NPE outlet, and CPU Die. It also displays the low and high critical voltage thresholds, and low and high shut down voltage thresholds for the power rails on the NPE-G2 in the Cisco 7200 VXR.
Note
The low range temperatures, such as the LowShut, LowCrit, and LowWarn temperature thresholds, are not checked and are not displayed on the NPE-G2. Also the warning voltage thresholds, such as LowWarn and HighWarn, are not checked and are not displayed on the NPE-G2.
Router_npe-g2# show environment tableSample Point LowShut LowCrit LowWarn HighWarn HighCrit HighShutNPE Inlet 44C/111F 59C/138FNPE Outlet 49C/120F 64C/147FCPU Die 75C/167F 85C/185FSystem shutdown for NPE Inlet is 80C/176FSystem shutdown for NPE Outlet is 84C/183FSystem shutdown for CPU Die is 100C/212F+3.30 V +2.30 +3.12 +3.47 +4.29+1.50 V +1.05 +1.40 +1.56 +1.95+2.50 V +1.71 +2.34 +2.61 +3.28+1.80 V +1.25 +1.67 +1.91 +2.34+1.20 V +0.82 +1.13 +1.28 +1.56VDD_CPU +0.89 +1.21 +1.36 +1.71VDD_MEM +1.71 +2.34 +2.61 +3.28VTT +0.85 +1.17 +1.32 +1.64+3.45 V +2.38 +3.28 +3.63 +4.49-11.95 V -8.44 -11.56 -12.84 -15.78+5.15 V +3.59 +4.88 +5.42 +6.71+12.15 V +8.55 +11.48 +12.77 +15.82
Cisco 7000 Series Routers
The following are examples of messages that display on the system console when a measurement has exceeded an acceptable margin:
ENVIRONMENTAL WARNING: Air flow appears marginal.ENVIRONMENTAL WARNING: Internal temperature measured 41.3(C)ENVIRONMENTAL WARNING: +5 volt testpoint measured 5.310(V)The system displays the following message if voltage or temperature exceed maximum margins:
SHUTDOWN: air flow problemIn the following example, there have been two intermittent power failures since a router was turned on, and the lower power supply is not functioning. The last intermittent power failure occurred on Monday, June 10, 1996, at 11:07 p.m.
7000# show environment allEnvironmental StatisticsEnvironmental status as of 23:19:47 UTC Wed Jun 12 1996Data is 6 second(s) old, refresh in 54 second(s)WARNING: Lower Power Supply is NON-OPERATIONALLower Power Supply:700W, OFF Upper Power Supply: 700W, ONIntermittent Powerfail(s): 2 Last on 23:07:05 UTC Mon Jun 10 1996+12 volts measured at 12.05(V)+5 volts measured at 4.96(V)-12 volts measured at -12.05(V)+24 volts measured at 23.80(V)Airflow temperature measured at 38(C)Inlet temperature measured at 25(C)Table 5 describes the significant fields shown in the display.
The following example is for the Cisco 7000 series router. The router retrieves the environmental statistics at the time of the last shutdown. In this example, the last shutdown was Friday, May 19, 1995, at 12:40 p.m., so the environmental statistics at that time are displayed.
Router# show environment lastEnvironmental StatisticsEnvironmental status as of 14:47:00 UTC Sun May 21 1995Data is 6 second(s) old, refresh in 54 second(s)WARNING: Upper Power Supply is NON-OPERATIONALLAST Environmental StatisticsEnvironmental status as of 12:40:00 UTC Fri May 19 1995Lower Power Supply: 700W, ON Upper Power Supply: 700W, OFFNo Intermittent Powerfails+12 volts measured at 12.05(V)+5 volts measured at 4.98(V)-12 volts measured at -12.00(V)+24 volts measured at 23.80(V)Airflow temperature measured at 30(C)Inlet temperature measured at 23(C)Table 6 describes the significant fields shown in the display.
The following example shows sample output for the current environmental status in tables that list voltage and temperature parameters. There are three warning messages: one each about the lower power supply, the airflow temperature, and the inlet temperature. In this example, voltage parameters are shown to be in the normal range, airflow temperature is at a critical level, and inlet temperature is at the warning level.
Router> show environment tableEnvironmental StatisticsEnvironmental status as of Mon 11-2-1992 17:43:36Data is 52 second(s) old, refresh in 8 second(s)WARNING: Lower Power Supply is NON-OPERATIONALWARNING: Airflow temperature has reached CRITICAL level at 73(C)WARNING: Inlet temperature has reached WARNING level at 41(C)Voltage Parameters:SENSE CRITICAL NORMAL CRITICAL-------|--------------------|------------------------|--------------------+12(V) 10.20 12.05(V) 13.80+5(V) 4.74 4.98(V) 5.26-12(V) -10.20 -12.05(V) -13.80+24(V) 20.00 24.00(V) 28.00Temperature Parameters:SENSE WARNING NORMAL WARNING CRITICAL SHUTDOWN-------|-------------|------------|-------------|--------------|-----------Airflow 10 60 70 73(C) 88Inlet 10 39 41(C) 46 64Table 7 describes the significant fields shown in the display.
Cisco 7200 Series Routers
The system displays the following message if the voltage or temperature enters the "Warning" range:
%ENVM-4-ENVWARN: Chassis outlet 3 measured at 55C/131FThe system displays the following message if the voltage or temperature enters the "Critical" range:
%ENVM-2-ENVCRIT: +3.45 V measured at +3.65 VThe system displays the following message if the voltage or temperature exceeds the maximum margins:
%ENVM-0-SHUTDOWN: Environmental Monitor initiated shutdownThe following message is sent to the console if a power supply has been inserted or removed from the system. This message relates only to systems that have two power supplies.
%ENVM-6-PSCHANGE: Power Supply 1 changed from Zytek AC Power Supply to removedThe following message is sent to the console if a power supply has been powered on or off. In the case of the power supply being shut off, this message can be due to the user shutting off the power supply or to a failed power supply. This message relates only to systems that have two power supplies.
%ENVM-6-PSLEV: Power Supply 1 state changed from normal to shutdownThe following is sample output from the show environment all command on the Cisco 7200 series router when there is a voltage warning condition in the system:
7200# show environment allPower Supplies:Power supply 1 is unknown. Unit is off.Power supply 2 is Zytek AC Power Supply. Unit is on.Temperature readings:chassis inlet measured at 25C/77Fchassis outlet 1 measured at 29C/84Fchassis outlet 2 measured at 36C/96Fchassis outlet 3 measured at 44C/111FVoltage readings:+3.45 V measured at +3.83 V:Voltage in Warning range!+5.15 V measured at +5.09 V+12.15 measured at +12.42 V-11.95 measured at -12.10 VTable 8 describes the significant fields shown in the display.
The following example is for the Cisco 7200 series router. This example shows the measurements immediately before the last shutdown and the reason for the last shutdown (if appropriate).
7200# show environment lastchassis inlet previously measured at 27C/80Fchassis outlet 1 previously measured at 31C/87Fchassis outlet 2 previously measured at 37C/98Fchassis outlet 3 previously measured at 45C/113F+3.3 V previously measured at 4.02+5.0 V previously measured at 4.92+12.0 V previously measured at 12.65-12.0 V previously measured at 11.71last shutdown reason - power supply shutdownTable 9 describes the significant fields shown in the display.
The following example is for the Cisco 7200 series router. This information lists the temperature and voltage shutdown thresholds for each sensor.
7200# show environment tableSample Point LowCritical LowWarning HighWarning HighCriticalchassis inlet 40C/104F 50C/122Fchassis outlet 1 43C/109F 53C/127Fchassis outlet 2 75C/167F 75C/167Fchassis outlet 3 55C/131F 65C/149F+3.45 V +2.76 +3.10 +3.80 +4.14+5.15 V +4.10 +4.61 +5.67 +6.17+12.15 V +9.72 +10.91 +13.37 +14.60-11.95 V -8.37 -9.57 -14.34 -15.53Shutdown system at 70C/158FTable 10 describes the significant fields shown in the display.
Cisco 7500 Series Router
The sample output for the Cisco 7500 series routers may vary depending on the specific model (for example, the Cisco 7513 router). The following is sample output from the show environment all command on the Cisco 7500 series router:
7500# show environment allArbiter type 1, backplane type 7513 (id 2)Power supply #1 is 1200W AC (id 1), power supply #2 is removed (id 7)Active fault conditions: noneFan transfer point: 100%Active trip points: Restart_Inhibit15 of 15 soft shutdowns remaining before hard shutdown10123456789012Dbus slots: X XX Xcard inlet hotpoint exhaustRSP(6) 35C/95F 47C/116F 40C/104FRSP(7) 35C/95F 43C/109F 39C/102FShutdown temperature source is `hotpoint' on RSP(6), requested RSP(6)+12V measured at 12.31+5V measured at 5.21-12V measured at -12.07+24V measured at 22.08+2.5 reference is 2.49PS1 +5V Current measured at 59.61 A (capacity 200 A)PS1 +12V Current measured at 5.08 A (capacity 35 A)PS1 -12V Current measured at 0.42 A (capacity 3 A)PS1 output is 378 WTable 11 describes the significant fields shown in the display.
The following example is for the Cisco 7500 series router. This example shows the measurements immediately before the last shutdown.
7500# show environment lastRSP(4) Inlet previously measured at 37C/98FRSP(4) Hotpoint previously measured at 46C/114FRSP(4) Exhaust previously measured at 52C/125F+12 Voltage previously measured at 12.26+5 Voltage previously measured at 5.17-12 Voltage previously measured at -12.03+24 Voltage previously measured at 23.78Table 12 describes the significant fields shown in the display.
The following example is for the Cisco 7500 series router. This information lists the temperature and voltage thresholds for each sensor. These thresholds indicate when error messages occur. There are two level of messages: warning and critical.
7500# show environment tableSample Point LowCritical LowWarning HighWarning HighCriticalRSP(4) Inlet 44C/111F 50C/122FRSP(4) Hotpoint 54C/129F 60C/140FRSP(4) Exhaust+12 Voltage 10.90 11.61 12.82 13.38+5 Voltage 4.61 4.94 5.46 5.70-12 Voltage -10.15 -10.76 -13.25 -13.86+24 Voltage 20.38 21.51 26.42 27.652.5 Reference 2.43 2.51Shutdown boards at 70C/158FShutdown power supplies at 76C/168FRestart after shutdown below 40C/104FTable 13 describes the significant fields shown in the display.
Cisco AS5300 Series Access Servers
In the following example, keywords and options are limited according to the physical characteristics of the system is shown:
as5300# show environment ?all All environmental monitor parameterslast Last environmental monitor parameterstable Temperature and voltage ranges| Output modifiers<cr>as5300# show environment table%This option not available on this platformCisco 12000 Series GSRs
The following examples are for the Cisco 12000 series GSRs.
The following is sample output from the show environment command for a Cisco 12012 router. Slots 0 through 11 are the line cards, slots 16 and 17 are the clock and scheduler cards, slots 18 through 20 are the switch fabric cards, slots 24 through 26 are the power supplies, and slots 28 and 29 are the blowers. An "NA" in the table means that no values were returned. In some cases it is because the equipment is not supported for that environmental parameter (for example, the power supply and blowers in slots 24, 26, 28, and 29 do not have a 3V power supply, so an NA is displayed).
Router# show environmentSlot # 3V 5V MBUS 5V Hot Sensor Inlet Sensor(mv) (mv) (mv) (deg C) (deg C)0 3300 4992 5040 42.0 37.02 3296 4976 5136 40.0 33.04 3280 4992 5120 38.5 31.57 3280 4984 5136 42.0 32.09 3292 4968 5160 39.5 31.511 3288 4992 5152 40.0 30.516 3308 NA 5056 42.5 38.017 3292 NA 5056 40.5 36.518 3304 NA 5176 36.5 35.019 3300 NA 5184 37.5 33.520 3304 NA 5168 36.5 34.024 NA 5536 5120 NA 31.526 NA 5544 5128 NA 31.528 NA NA 5128 NA NA29 NA NA 5104 NA NASlot # 48V AMP_48(Volt) (Amp)24 46 1226 46 19Slot # Fan 0 Fan 1 Fan 2(RPM) (RPM) (RPM)28 2160 2190 216029 2130 2190 2070Router#Table 14 describes the significant fields shown and lists the equipment supported by each environmental parameter. "NA" indicates that the reading could not be obtained, so the command should be run again.