Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.1(2)
Viewing Server Sensors
Downloads: This chapterpdf (PDF - 399.0KB) The complete bookPDF (PDF - 1.25MB) | Feedback

Viewing Server Sensors

Viewing Server Sensors

This chapter includes the following sections:

Viewing Current Sensors

Procedure
  Command or Action Purpose
Step 1 Server# scope sensor  

Enters sensor command mode.

 
Step 2 Server /sensor # show current [detail] 

Displays current sensor statistics for the server.

 

This example displays current sensor statistics:

Server# scope sensor
Server /sensor # show current
Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
VR_P2_IMON                Normal         16.00      AMP        N/A          147.20       N/A          164.80       
VR_P1_IMON                Normal         27.20      AMP        N/A          147.20       N/A          164.80       

Server /sensor #             

Viewing Power Supply Sensors

Procedure
  Command or Action Purpose
Step 1 Server# scope sensor  

Enters sensor command mode.

 
Step 2 Server /sensor # show psu [detail] 

Displays power supply sensor statistics for the server.

 
Step 3 Server /sensor # show psu-redundancy [detail] 

Displays power supply redundancy sensor status for the server.

 

This example displays power supply sensor statistics:

Server# scope sensor
Server /sensor # show psu
Name                 Sensor Status        Reading    Units      Min. Warning    Max. Warning    Min. Failure    Max. Failure    
-------------------- -------------------- ---------- ---------- --------------- --------------- --------------- --------------- 
PSU1_STATUS          Normal               present                                                                               
PSU2_STATUS          Normal               present  
                                                                             
Server /sensor # show psu-redundancy             
Name                 Reading    Sensor Status        
-------------------- ---------- -------------------- 
PSU_REDUNDANCY       full       Normal               

Server /sensor #

Viewing Fan Sensors

Procedure
  Command or Action Purpose
Step 1 Server# scope sensor  

Enters sensor command mode.

 
Step 2 Server /sensor # show fan [detail] 

Displays fan sensor statistics for the server.

 

This example displays fan sensor statistics:

Server# scope sensor
Server /sensor # show fan
Name                 Sensor Status  Reading    Units      Min. Warning    Max. Warning    Min. Failure    Max. Failure    
-------------------- -------------- ---------- ---------- --------------- --------------- --------------- --------------- 
W793_FAN2_TACH1      Normal         2400       RPM        N/A             N/A             800             N/A             
W793_FAN2_TACH2      Normal         2400       RPM        N/A             N/A             800             N/A             
W793_FAN3_TACH1      Normal         2300       RPM        N/A             N/A             800             N/A             
W793_FAN3_TACH2      Normal         2300       RPM        N/A             N/A             800             N/A             
W793_FAN4_TACH1      Normal         2400       RPM        N/A             N/A             800             N/A             
W793_FAN4_TACH2      Normal         1600       RPM        N/A             N/A             800             N/A             

Server /sensor #             

Viewing Temperature Sensors

Procedure
  Command or Action Purpose
Step 1 Server# scope sensor  

Enters sensor command mode.

 
Step 2 Server /sensor # show temperature [detail] 

Displays temperature sensor statistics for the server.

 

This example displays temperature sensor statistics:

Server# scope sensor
Server /sensor # show temperature
Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
IOH_TEMP_SENS             Normal         32.0       C          N/A          80.0         N/A          85.0         
P2_TEMP_SENS              Normal         31.0       C          N/A          80.0         N/A          81.0         
P1_TEMP_SENS              Normal         34.0       C          N/A          80.0         N/A          81.0         
DDR3_P2_D1_TMP            Normal         20.0       C          N/A          90.0         N/A          95.0         
DDR3_P1_A1_TMP            Normal         21.0       C          N/A          90.0         N/A          95.0         
FP_AMBIENT_TEMP           Normal         28.0       C          N/A          40.0         N/A          45.0         

Server /sensor #             

Viewing Voltage Sensors

Procedure
  Command or Action Purpose
Step 1 Server# scope sensor  

Enters sensor command mode.

 
Step 2 Server /sensor # show voltage [detail] 

Displays voltage sensor statistics for the server.

 

This example displays voltage sensor statistics:

Server# scope sensor
Server /sensor # show voltage
Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
P3V_BAT_SCALED            Normal         3.022      V          N/A          N/A          2.798        3.088        
P12V_SCALED               Normal         12.154     V          N/A          N/A          11.623       12.331       
P5V_SCALED                Normal         5.036      V          N/A          N/A          4.844        5.157        
P3V3_SCALED               Normal         3.318      V          N/A          N/A          3.191        3.381        
P5V_STBY_SCALED           Normal         5.109      V          N/A          N/A          4.844        5.157        
PV_VCCP_CPU1              Normal         0.950      V          N/A          N/A          0.725        1.391        
PV_VCCP_CPU2              Normal         0.891      V          N/A          N/A          0.725        1.391        
P1V5_DDR3_CPU1            Normal         1.499      V          N/A          N/A          1.450        1.548        
P1V5_DDR3_CPU2            Normal         1.499      V          N/A          N/A          1.450        1.548        
P1V1_IOH                  Normal         1.087      V          N/A          N/A          1.068        1.136        
P1V8_AUX                  Normal         1.773      V          N/A          N/A          1.744        1.852        

Server /sensor #